© 2011 columbia technologies. use of mihpt systems to improve project outcomes rapid, real-time...

39
© 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization 2013 COLUMBIA Technologies.

Upload: alexander-truelock

Post on 14-Dec-2015

215 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Use of MiHpt Systems to Improve Project Outcomes

Rapid, Real-Time High Resolution Site Characterization

© 2013 COLUMBIA Technologies.

Page 2: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 2

Presentation Outline

• Basic Mechanics of the MiHpt and LLMiHpt• Interpretation of MiHpt and LLMiHpt data• Project Examples–Mixed VOCs, Gasoline, and TCE• Investigation Design• Collaborative Data Sets• Future Field Test of VOC Speciation

Page 3: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 3

MiHpt Diagram

Page 4: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 4

Page 5: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Depth Detector

MiHpt Transfer

Line

Drill Rods

Electrical Generator

(self sufficient)

Ultra Pure Compressed Gases

© 2013 COLUMBIA Technologies. 5

Page 6: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Membrane Interface Probe (MIP)Quick Notes:- Volatile Organic Compounds (VOCs), 60 measurements/foot- Vapor, Dissolved Phase, Sorbed Phase,

some NAPL- Typical DL: 1 ppm fuel / 200 ppb solvent

(can be lower with special procedures)

- Low Level DL: 1 to 50 ppb VOCs , 3 measurement/foot

6

Page 7: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Sample HPT Log

Hydraulic Profiling Tool (HPT)

© 2013 COLUMBIA Technologies. 7

Quick Notes:- Water injected at approx . 100 ml/min- 20 measurements per foot, flow rate, pressure and EC -Dissipation test to determine head of water over probe.-Pressure and flow measurements collected from below the groundwater surface can be converted to approximations of K .

Page 8: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. . 8

HPT Log X-section – EC and Pressure

Page 9: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 9

Gasoline Plume and PCE Plume Separation

Gasoline migration at shallower depth vs deeper PCE, both in thin layers of higher permeability as defined by HPT data

PCE Plume defined by XSD

Gasoline Plume defined by PID

Page 10: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 10

LLMiHpt Log

Page 11: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 11

Project Examples

• MIP/EC Data – Mixed CVOC Plume – Australia• MiHpt Data – Gasoline Plume - US• MIP/EC, MiHpt, and LLMiHpt – TCE Plume - US

Page 12: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 12

MIP Project Example

• Provide Example to AU Regulators of HRSC.• Focus Remediation Efforts for Property

Redevelopment.

Page 13: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 13

Layout of SC/MIP soundings on the Project Site

Page 14: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

X-section through soil electrical conductivity (EC) data (EC data shows alluvium of interbedded silts and sands, silts-yellow

shading sand-green and blue)

Page 15: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 15

Plan-view through MIP XSD Data

Page 16: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 16

X-Section through MIP XSD Data

Page 17: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Plain-View through FID (flame ionisation detector) Data at a depth of 3 metres

Page 18: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

X-section through FID (flame ionisation detector) data

Page 19: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 19

MIP XSD Volume Calculations

Page 20: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 20

MiHpt Gasoline Example

• Provide evidence of separate gasoline plumes.

• Regulators attempting to assign remediation costs.

Page 21: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 21

MIP PID 0 to 2 feet

Page 22: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 22

MIP PID 0 to 6 feet

Page 23: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

MIP PID 0 to 12 feet

Page 24: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 24

MIP PID 22 to 28 feet

Page 25: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 25

Benzene in groundwater map

Page 26: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. . 26

MiHpt PID/Pressure X-sections through the gasoline plume

Page 27: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 27

MIP/EC, MiHpt and LLMiHpt Example

• Define lateral and vertical distribution of TCE to determine if vapor is impacting potential receptors.

Page 28: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. . 28

Page 29: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 29

X-section MIP/EC, MiHpt, LLMiHpt

Page 30: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 30

Investigation Design

• Business Goals.• Detailed Conceptual Site Model.• Anchor Points – Existing Wells or Borings.• Source areas. • Property boundaries. • Define exposure to receptors.• Grid approach for pre-defined remediation

areas.

Page 31: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. . 31

Collaborative Data Sets

• Soil, Groundwater, Soil Vapor Analytical, • Lithology, • Geochemistry, • Permeability to water, • LNAPL Transmissivity, • ISCO Radius of Influence

Page 32: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.32

In-well baffle device/Mixing inhibitor

Britt, SL and Calabria M, 2008, Baffles may allow effecting multilevel monitoring in traditional monitoring wells, Battelle Chlorcon Conference, Monterey California, May 2008

Snap Sampler – ProHydro Inc.

Page 33: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 33

MIP Data Used in Well Design

Page 34: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 34

Page 35: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 35

Draft of Converting MiHpt data to Mass Flux

Page 36: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

Mass transport zones< 10% of area

Page 37: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. © 2012 COLUMBIA Technologies. 37

Future Field Test of VOC Speciation

• Mobile GC analysis of MIP Gas Stream• Speciation of a Target List of VOCs• Analytical Results on 7 minute Intervals

Page 38: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies.

www.defiant-tech.com

1/16” SwageLok

PCE

TCE

Cis-

1,2-

DCE

tran

s-1,

2-D

CE

FROG-4000

Detect VOCs in air down to 0.5ppbv.

Sampling Sub-slab port in Indianapolis

Page 39: © 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies

© 2011 COLUMBIA Technologies. 39

One More Final Thought

It is far better to be approximately correct with a huge data set than precisely wrong with a limited data set.

Thank You!

Questions?

www.columbiatechnologies.com

© 2013 COLUMBIA Technologies.