Best Pneumatics Vol. 14 0 3 Series IR Series IRV Pressure Control Equipment Regulators Miniature Regulator: ARJ1020F/210/310 ······························· P. 14-4-4 Pilot Operated Regulator: AR425 to 925, AR435 to 935 ········ P. 14-4-15 Compact Manifold Regulator: ARM10/11 ································ P. 14-4-19 Manifold Regulator: ARM ························································ P. 14-4-52 Direct Operated Precision Regulator: ARP ····························· P. 14-4-59 Regulator for 2 MPa: ARX20 ··················································· P. 14-4-62 Precision Regulator: IR1000/2000/3000 ································· P. 14-5-1 Vacuum Regulator: IRV1000/2000/3000 ································· P. 14-5-17 Precision Regulator: VEX13 ··············································· P. 14-6-1 Combination MR Unit: AMR ········································································· P. 14-7-1 New Function/Multi-application Valves Compact Electro-pneumatic Regulator: ITV0000 ···················· P. 14-8-1 Electro-pneumatic Regulator: ITV1000/2000/3000 ················· P. 14-8-14 Electronic Vacuum Regulator: ITV209 ·································· P. 14-8-30 Controller for Electro-pneumatic Regulator: IC ························ P. 14-8-35 Booster Regulator: VBA ·························································· P. 14-9-1 Electro-pneumatic Proportional Control Valve: VEF/VEP ········ P. 14-9-11 5 Port Electro-pneumatic Proportional Control Valve: VER2000/4000 ···· P. 14-9-17 Power Amplifier for Electo-pneumatic Proportional Valve: VEA···· P. 14-9-24 Electro-pneumatic HYREG ® : VY1 ············································ P. 14-10-1 14-4-1 F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Upload: ngonguyet

Post on 10-Dec-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Best Pneumatics Vol. 14

03

Series IR

Series IRV

Pressure Control Equipment� Regulators

Miniature Regulator: ARJ1020F/210/310 ······························· P. 14-4-4

Pilot Operated Regulator: AR425 to 925, AR435 to 935 ········ P. 14-4-15

Compact Manifold Regulator: ARM10/11 ································ P. 14-4-19

Manifold Regulator: ARM ························································ P. 14-4-52

Direct Operated Precision Regulator: ARP ····························· P. 14-4-59

Regulator for 2 MPa: ARX20 ··················································· P. 14-4-62

Precision Regulator: IR1000/2000/3000 ································· P. 14-5-1

Vacuum Regulator: IRV1000/2000/3000 ································· P. 14-5-17

Precision Regulator: VEX1�3 ··············································· P. 14-6-1

� Combination

MR Unit: AMR ········································································· P. 14-7-1

� New Function/Multi-application Valves

Compact Electro-pneumatic Regulator: ITV0000 ···················· P. 14-8-1

Electro-pneumatic Regulator: ITV1000/2000/3000 ················· P. 14-8-14

Electronic Vacuum Regulator: ITV209� ·································· P. 14-8-30

Controller for Electro-pneumatic Regulator: IC ························ P. 14-8-35

Booster Regulator: VBA ·························································· P. 14-9-1

Electro-pneumatic Proportional Control Valve: VEF/VEP ········ P. 14-9-11

5 Port Electro-pneumatic Proportional Control Valve: VER2000/4000 ···· P. 14-9-17

Power Amplifier for Electo-pneumatic Proportional Valve: VEA···· P. 14-9-24

Electro-pneumatic HYREG®: VY1 ············································ P. 14-10-1

14-4-1

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-2

RegulatorsSeries

Miniature regulatorARJ1020F

Direct operated relieving typeBack flow function

ManifoldM5 0.1 to 0.7

Miniature regulatorARJ210

Direct operated relieving type BracketPressure gauge

M5 to 0.2 to 0.7

Application/Characteristics Port size Set pressure (MPa) Option Page

18

18

Miniature regulatorARJ310

Small, compactAllows smaller mounting pitch

BracketPressure gauge

M5 0.2 to 0.71

8

to 214Pilot operated regulator

AR425-925AR435-935Compact manifold regulatorARM10/11

Internal pilot typeRelieving type

BracketPressure gauge

0.05 to 0.830.02 to 0.2

Manifold regulatorARM1000/2000

Manifold(Common IN/Individual IN)Direct operated relieving typeBack flow function

Pressure gauge0.08 to 0.7

to 1 21

8

to 1 21

8

, 38

14

, 14

18

Manifold regulatorARM2500/3000

Manifold(Common IN/Individual IN)Modular type

BracketPressure gauge

0.05 to 0.85

14Direct operated

precision regulatorARP3000

Setting sensitivity: 0.001 MPaDirect operated relieving type

BracketPressure gauge

0.005 to 0.3

Regulator for 2 MPaARX20

Compatible with inlet supply pressure of 2.0 MPa

BracketPressure gaugePanel nut

Standard type0.05 to 0.85 MPaLow pressure type0.05 to 0.3 MPa

Vacuum regulatorIRV1000/2000/3000

Able to adjust the pressure forvacuum line

BracketPressure gauge

–100 to –1.3 kPa

(IR1000/2000)0.005 to 0.20.005 to 0.40.005 to 0.8(IR3000)0.01 to 0.20.01 to 0.40.01 to 0.8

Precision regulatorIR1000/2000/3000

Tension controlContact pressure controlSetting sensitivity: 0.2% F.S.Repeatability: ±0.5% F.S.

BracketPressure gauge

Precision regulatorVEX1�3

Large capacity exhaustregulatorsSetting sensitivity: 0.2% F.S.Repeatability: ±0.5% F.S.

BracketFootPressure gaugeSilencer

14-4-4

14-4-6

14-4-11

14-4-15

14-4-19

14-4-52

14-4-55

14-4-59

14-4-61

14-5-15

14-5-1

14-6-1M5 to 2

0.01 to 0.70.05 to 0.71

830 /

/

/

/

/

/

/

/

/

/

/

/

/

/

Pressure Control Equipment

0.05 to 0.7Manifold

CombinationSeries Application/Characteristics Port size Set pressure (MPa) Option Page

New Function/Multi-application ValvesSeries Application/Characteristics Port size Set pressure (MPa) Option

MR unitAMR3000-6000

Mist seperator andregulator integratedFiltration: 0.3 µm

Adapter assemblyAuto-drainPressure gauge

0.05 to 0.85 14-7-1 to 1/14

Fil.

to 12

18

Electronic vacuum regulatorITV209�

–1.3 to –80 kPa 14-8-3014

Electro-pneumatic regulatorITV1000/2000/3000

Bracket0.005 to 0.10.005 to 0.50.005 to 0.9

14-8-14

Compact electro-pneumatic regulatorITV0000

BracketCable connectors

14-8-3

Controller for electro-pneumatic regulatorIC

Pressure gaugeSilencerAir tank

0.2 to 2.0 (VBA1110)0.2 to 1.0 (VBA4200)

14-9-1

ITV001�: 0.001 to 0.1 MPaITV003�: 0.001 to 0.5 MPaITV005�: 0.001 to 0.9 MPaITV009�: –1 to –100 kPa

0.1 to 0.9

to 1 21

4

Electro-pneumatic proportional valveVEF2000/3000VEP2000/3000

Dedicated power amplifier 14-9-11

Page

to 3 41

4

5 port electro-pneumatic proportional control valveVER2000/4000

Dedicated power amplifier 14-9-17 to 3 41

4

0.05 to supply pressureElectro-pneumatic HYREG®

Series VY1BracketPressure gaugeSilencer

14-10-1M5 to 2

For single unit ø4For manifolds ø6

/ /

/ /

/

/

/

/

/

Realizes space savings and re-duction of weight for manifold use.

Pressure controlled steplessly by electric signals Electrostatic paint-ing

Pressure controlled steplessly by electric signals

Pressure increased up to 2 times the inlet pressure

Pressure and flow rate controlled step-lessly by electric signalsPressure control for press die cushion, solvent bridge and low pressure castingMultistage speed control of air cylinders and rpm control of air motorsExclusive power amplifier

A single unit that actuates a cylinder and steplessly controls the applied pressureApplicable cylinders: ø25 to ø125Exhaust air throttling or B port pressure reduction possible

Pressure controlled steplessly by electric signalsCylinder thrust controlCylinder thrust control nozzle suc-tion flow control Pressure control of the tank

Booster regulatorVBA1110-4200

Panel mount adapter setDisplay protective cover

14-8-35M5 female(Built-in sensor type)

Converts digital input signal into analog output signal

14-4-3

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR)) Inlet pressure (MPa)

Initial set point

Miniature Regulator

Series ARJ1020FStandard Specifications

Model

Fluid

OUT side (Applicable tubing O.D.)

IN sidePortsize

Ambient and fluid temperature

Construction

Weight (kg)

Cracking pressure (Valve)

Applicable tubing material

Proof pressure

Maximum operating pressure

Regulating pressure range

ARJ1020F

Description

Manifold base

Part no.

ARJM10-4, -6, -10

M5ARJ 2010

Port size

Option

M5 M5 x 0.8

04

Applicable tubing O.D.04 4 mm06 6 mm

20 Elbow type

1 0.2 MPa setting

Body size

Miniatureregulator

Piping

10 M5

How to Order

Accessory (Option)/Part No.

Max. effective area (OUT � IN)

ø6ø4

0.0160.015

M5 (Male thread)

Air

1.2 MPa

0.02 MPa

1.8 mm2

0.8 MPa

0.1 to 0.7 MPa

0.2 MPa setting 0.05 to 0.2 MPa

–5 to 60°C (No freezing)

Relieving type

Nylon, Soft nylon, Polyurethane

1

With One-touch fitting

F

Note)

Note) Be sure to note the maximum operating pressure for soft nylon and polyurethane. (Refer to Best Pneumatics Vol. 15.)

Inlet pressure: 0.7 MPa

Pressure Characteristics

Flow Characteristics

Conditions (Initial setting)Inlet pressure: 0.7 MPa

Outlet pressure: 0.2 MPaFlow rate: 10 �/min (ANR)

ARJ1020F-M5-06ARJ1020F-M5-04

ARJM10-6

JIS Symbol

Note 1) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.

� Compact and lightweight (16 g)

� Low cracking pressure 0.02 MPaStandard model equipped with backflow function

14-4-4

Warning

Manifold Base (Option)/Dimensions

Component Parts

Dimensions

No. Description

B dimension

NoteBodyValve guidePistonBonnetHandleAdjusting springValveNipple

PBTBrass

Polyacetal BrassBrass

Steel wireBrassBrass

Electroless nickel plated

Electroless nickel platedElectroless nickel plated

Zinc chromatedRubber lining

Electroless nickel plated

Material

82122202

K

17.2

ARJM10-4ARJM10-6ARJM10-10

q

w

e

r

t

y

u

!0

Replacement PartsNo. Description Part no.

13434-30

P233014-04

134313

Valve

Gasket

Spring

Brass, HNBRStainless steel

NBRStainless steel

Materialu

i

o

A dimension

90130210

StationsManifold

base part no.

4 610

J

50

H

15.5

G

3.5

E

6

D

M5 x 0.8

F

10.6(Width across

flats: 10)

C4

6

B10.4

12.8

AModelARJ1020F-M5-04

ARJ1020F-M5-06

21

22

Piping

Mounting/Adjustment

Construction/Dimensions

1. Set up the regulator while verifying the pressure that is indicated on the inlet and the outlet pressure gauges. Turning the handle excessively could damage the internal parts.

1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.<Lock operating method>Loosen the lock nut to unlock it, and tighten it to lock it.

2. This product cannot be used as a check regulator by installing it between solenoid valve and actuator.

Be sure to read before handling.Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Lock nutM8 X 0.75

Panel screw

MAX. 2.5t

Applicable tubing O.D. C

Panel mounting hole31

(A

RJ1

020F

-M5-

04)

32 (

AR

J102

0F-M

5-06

)

(Mounting hole)

IN (Common)

Applicable tubing O.D. ø4, ø6

1. To connect the IN side, hold the valve guide at its wrench flats (opposite side 10) and tighten it at the recommended torque of 1.5 to 2 N·m. Excessive torque or holding it at an area other than the specified portion may result in a malfunction.

2. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage.

∗ When replacing valves and springs, remove nipple first. Note that adhesive is applied to the nipple portion.

Precautions

Warning

Caution

2-ø3.5(Mounting hole)

14-4-5

Miniature Regulator Series ARJ1020F

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR)) Inlet pressure (MPa)

Initial set pointInitial set pointInitial set point

Standard SpecificationsModel

OUT side

IN side

Fluid

Port size

Pressure gauge port size

Ambient and fluid temperature

Weight (kg)

Proof pressure

Maximum operating pressure

Regulating pressure range

ARJ210-M5

1/8 (Male thread), M5 x 0.8 (Female thread)

M5 x 0.8 (Female thread 2 pcs.)

Bracket

Pressure gauge

134856

G27-10-M5-X201

M5ARJ 10 BG

Port size

Option

Accessory

M5IN

OUT M5 x 0.8 (Female thread)

(Male thread)M5 x 0.8 (Female thread)

Symbol DescriptionNilBG

With bracketWith pressure gauge

1 Relieving type (Standard)

1 0.2 MPa setingS With seal

Body size

Miniatureregulator

Model

Air

How to Order

Accessory (Option)/Part No.

1.2 MPa

0.8 MPa

0.2 to 0.7 MPa

0.2 MPa setting 0.05 to 0.2 MPa

0.06

M5 x 0.8 (Female thread)

–5 to 60°C (No freezing)

12

ARJ210-M5BG

ARJ210-M5

1 8

Note)

Miniature Regulator

Series ARJ210

JIS Symbol

Pressure Characteristics

Flow Characteristics Inlet pressure: 0.7 MPa

(Initial setting)Inlet pressure: 0.7 MPa

Outlet pressure: 0.2 MPaFlow rate: 20 � /min (ANR)

Note) If ordering the pressure gauge, M-5N (nipple) is required. Part number of the pressure gauge with a nipple assembled is G27-10-M5-X215.

Note 1) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.

� Lightweight body made of aluminum (60 g)

� Two styles of piping connections provided for the IN side: 1/8 (male thread) and M5 (female thread)

14-4-6

21 (W

idth a

cross

flats)

Lock nut

Panel mounting hole

Bracket(Option)

Pressure gauge(Option) M5 x 0.8

2-M5 x 0.8

M12 x 1

≅37

Max. 4t

Selection

Warning

Construction/Dimensions

No. DescriptionBodyValve guidePistonAdjusting screwAdjusting spring

Electroless nickel platedBlack anodized

Note

Electroless nickel platedZinc chromated

BrassBrass

Aluminum alloyMaterial

BrassSteel wire

q

w

e

r

t

Mounting/Adjustment

1. This product cannot be used as a check regulator by installing it between solenoid valve and actuator. Doing so could lead to equipment damage.

2. When connecting a pipe to the IN side, hold the valve guide at its wrench flats (opposite side 11), and when connecting to the OUT side, hold the body at its hexagon portion and tighten it to the recommended torque. (M5: 1.5 to 2 N·m, R 1/8: 7 to 9 N·m.) Excessive torque or holding it other than at the specified area could lead to equipment damage.

1. Set up the regulator while verifying the pressure that is indicated on the inlet and the outlet pressure gauges. Turning the handle excessively could damage the internal parts.

1. Release the lock to adjust the pressure. After the adjustment, engage the lock.Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.<Lock operating method>Loosen the lock nut to unlock it, and tighten it to lock it.

2. This product cannot be used as a check regulator by installing it between solenoid valve and actuator.

3. Port with a pressure gauge or a plug can be used as an OUT port.

Be sure to read before handling.Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Precautions

Warning

Caution

View A

14-4-7

Miniature Regulator Series ARJ210

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-8

Compact and lightweight (Main body 65 g)

Allows smaller mounting pitch

18.3

≅ 41

18.8 mm

Panel mounting type One-touch fitting featureintroduced to seriesø4, ø6 (Metric size)ø5/32", ø1/4" (Inch size)

Accommodates two types of threadsInside: Female thread (M5 x 0.8)Outside: Male thread (1/8)

Improved flow characteristics

Flow rate (� /min (ANR))

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 100 200 300 400 500

Out

let p

ress

ure

(MP

a)

ARJ210-M5

Inlet pressure: 0.7 MPaInlet pressure: 0.7 MPa

ARJ310-01

ARJ310-01G

≅ 82

.5

Miniature Regulator

Series ARJ310

14-4-9

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

To set the correct pressure1. Make connections after confirming the mark which indicates

the air inlet. Reversed connections can cause malfunction.

1. This product cannot be used as a check regulator by installing it between solenoid valve and actuator. It can result in causing breakdown and malfunction.

2. When piping, tighten the regulator with the recommended proper tightening torque (M5: 1.5 to 2 N·m, R 1/8: 7 to 9 N·m) while holding the wrench flats (width 11) of the valve guide for IN port and holding the hexagonal section of the body for the OUT port. Excessive tightening or holding a part other than those specified can cause damage.

3. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage.

Warning

Precautions

Design and Selection Mounting

Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Caution

Series ARJ310

14-4-10

How to Order

1/8 (Male thread), M5 x 0.8 (Female thread)01

Port size (IN)R, RcNPT

NilN

Thread type

NoneBracket

Pressure gauge

NilBG

Accessory

Relieving type10

ARJ 3 10 F BGWith One-touch fitting 0401

ARJ 3 10 01

Body size

With One-touch fitting

Model

0.7 MPa setting (Standard)0.2 MPa setting (1)

With seal

Nil1S

Option

ARJ310-014 mm6 mm

0406

Applicable tubing O.D. (OUT)Metric size

1/8 (Male thread), M5 x 0.8 (Female thread)1/8 (Female thread)

INOUT

01

Port size (IN, OUT)

ARJ310F-N015/32"1/4"

0307

Inch size

BG

Standard Specifications

Rc 1/8, NPT 1/8 (Female thread)Air

1.2 MPa0.8 MPa

Standard: 0.2 to 0.7 MPa, Low pressure use (0.2 MPa setting): 0.05 to 0.2 MPa

–5 to 60°C (With no freezing)Approx. 65 g

Pressure gauge port sizeFluidProof pressureMaximum operating pressure

Regulating pressure range

Ambient and operating temperature rangeWeight

Accessory (Option) Part No.

134856

G15-10-01 (Rc 1/8)/G15-P10-N01 (NPT 1/8)Bracket

Pressure gauge Note)

Note) Pressure gauges (G15) for 0.2 MPa are not available.

JIS Symbol

Model

Port sizeIN ∗

R 1/8, M5 x 0.8

NPT 1/8, M5 x 0.8

R 1/8, M5 x 0.8

NPT 1/8, M5 x 0.8

OUT

Rc 1/8

NPT 1/8

ø4 One-touch fitting

ø6 One-touch fitting

ø5/32" One-touch fitting

ø1/4" One-touch fitting

ARJ310-01ARJ310-N01ARJ310F-01-04ARJ310F-01-06ARJ310F-N01-03ARJ310F-N01-07

Model

∗ M5 x 0.8 female thread is cut inside the pipe.

Note 1) Compared with standard specifications, its adjusting spring has been only changed for 0.2 MPa. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable. Besides, in the case with the pressure gauge, the pressure gauge will be the one for 1 MPa.

Note 2) For products with pressure gauge, pressure gauge is shipped together with product.

Miniature Regulator

Series ARJ310

14-4-11

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Flow Characteristics

Pressure Characteristics

Construction

ARJ310-01

ARJ310-01 ARJF310F-01

ARJ310F-01-04 ARJ310F-01-06

Flow rate (� /min (ANR))

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 100 200 300 400 500 600

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR))

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 100 200 300 400 500 600

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR))

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 100 200 300 400 500 600

Out

let p

ress

ure

(MP

a)

0.10

0.15

0.20

0.25

0.30

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa)

Conditions:Inlet pressure 0.7 MPaOutlet pressure 0.2 MPaFlow rate Q = 20 �/min (ANR)

Inlet pressure: 0.7 MPa

ye

!1

q

o

r

!2

!6

i

!5

u

!4

!7

!3

!0

t

w

OUT

IN

No.q

w

e

r

t

y

u

i

o

!0

!1

!2

!3

!4

!5

!6

!7

DescriptionBodyValve guideBonnetPistonValveAdjusting screwPanel nutHexagon nutAdjusting springValve springSpring holderMini Y-sealO-ringLock washerBracketPressure gaugeCassette

Aluminum alloyBrassBrassPOMBrassBrassBrassBrass

Steel wireStainless steel

Steel bandNBRNBRSS

Steel band—

POM, Stainless steel

Material Note

Component Parts

Electroless nickel platedElectroless nickel plated

Rubber lining material: HNBRElectroless nickel platedElectroless nickel platedElectroless nickel plated

Zinc chromated

Zinc chromated

Electroless nickel platedAccessoryAccessory

Black zinc chromated

Set pointSet point

Series ARJ310

14-4-12

Dimensions

192

(Width across flats)11

18.3

32

≅27

≅82.

5

≅57.

28.

5

26

22 M12 x 1Panel cutout dimensions

ø12.5/Panel thickness: 4 or less

2-ø5.5

Port sizeRc, NPT 1/8

Applicable tubing O.D.Metric size ø4, ø6Inch size ø5/32", ø1/4"

M5 x 0.8 (Female thread)

13.6

1

2

1

2

26.1

R, NPT 1/8

Pressure gaugeport sizeRc, NPT 1/8

26.1 ≅3

15

≅31

≅56

≅35

≅56

ARJ310-01 ARJ310F-01

14-4-13

Miniature Regulator Series ARJ310

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-14

Pilot Operated Regulator

Series AR425 to 935

Regulatingpressure range

How to Order

Model

Port size

Fluid

Proof pressure

Max. operating pressure

Set pressure range (MPa)

Air consumption (for bleed hole)

Pressure gauge port size

Ambient and fluid temperature

Construction

Weight (kg)

AR425 AR435 AR625 AR635 AR825 AR835 AR925 AR935

Air

1.5 MPa

1.0 MPa

5 l/min (ANR) (at maximum pressure)

–5 to 60°C (No freezing)

Internal pilot relieving type (Pilot air is always bleeding.)

4.52.51.10.7

Accessory (Option)/Part No.Part no.

AR4�5 AR6�5 AR8�5 AR9�5Description Model

Bracket

Pressure gauge with limit indicator (1)

B24P B25P — —

G46-10-�02 (Max. 1.0 MPa), G46-2-�02 (Max. 0.2 MPa)

(2)

(1)

Note 1) • In the gauge part no. (e.g. G46-10-�02), � indicate kind of the connecting thread. Put nothing for Rc and “N” for NPT thread.• Please consult with SMC for NPT pressure gauge.

Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it may result in a breakdown. Use a pipe tape for sealing. Recommended torque: 12 to 14 N·m.

1/4, 3/8, 1/2 3/4, 1 1 , 1 241

41

21

0.05 to 0.83 0.02 to 0.2 0.05 to 0.83 0.02 to 0.2 0.05 to 0.83 0.02 to 0.2 0.05 to 0.83 0.02 to 0.2

Internal pilot operated relieving type regulator

AR 254 BG R02

Regulator

Body size

Thread type

Port size

Accessory

Nil

G

Gau

ge

Description Applicable model

With bracket AR4�5 to 6�5AR�25AR�35

21

21

41

B

Symbol1

2

1

2

G46-10-02G46-2-02

OptionNil

Flow direction: Right � Left

None

R

AR8�5 AR6�5

AR425-��BGAR6�5-��BG

Standard Specifications

4689

1

NilNF

RcNPT

G

2535

0.05 to 0.83 MPa

0203040610121420

1 4

83

1 23 4

11 21

Note) 0.02 to 0.2 MPaNote 1) Compared with AR�25

type, its adjusting spring will only be different.

Note 2) Compared with AR�25 type, its adjusting spring will only be changed for 0.2 MPa. It is not the product which does not allow the pressure more than 0.2 MPa.

JIS Symbol

Note 1) Outlet pressure range: P2 is 90% of P1 or less. Note 2) Air consumption differs depending on the set pressure. Due to the construction, the pressure gap between inlet and outlet cannot be set within 0.03 MPa, even if the handle is set at the maximum.

∗ Pressure gauges are shipped with regulator, (but not assembled).

14-4-15

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Flow rate (�/min (ANR)) Flow rate (�/min (ANR)) Inlet pressure (MPa)

Flow rate (�/min (ANR)) Flow rate (�/min (ANR)) Inlet pressure (MPa)

Flow rate (�/min (ANR)) Flow rate (�/min (ANR)) Inlet pressure (MPa)

Flow rate (�/min (ANR)) Flow rate (�/min (ANR)) Inlet pressure (MPa)

Set pointSet point

Set pointSet point

Set pointSet point

Set pointSet point

AR425 AR435 AR425/435

AR625 AR635 AR625/635

AR825 AR835 AR825/835

AR925 AR935 AR925/935

Flow Characteristics PressureCharacteristics

Inlet pressure: 0.7 MPa Inlet pressure: 0.7 MPaOutlet pressure: 0.2 MPaFlow rate: 20 � /min (ANR)

Series AR425 to 935

14-4-16

Warning

No.

No.

Description Material Note

Description MaterialPart no.

BodyBonnetChamberValve guide

q

w

e

r

t!1

y

u

o

!0

Replacement Parts

Stainless steelABS

Steel wire

AR425, 435132586A132581A132572A

135211

AR625, 635132586A132659A132653A

13265613414

Aluminum die-casted ∗Aluminum die-castedAluminum die-casted

Zinc die-casted ∗

Platinum silver paintedPlatinum silver paintedPlatinum silver paintedPlatinum silver painted

∗ In the case of AR825/835/925/935, the material is aluminum alloy.

Note) Diaphragm is included.

∗ For products with pressure gauge, pressure gauges are shipped together with product.

Component Parts

Adjusting springi135053 (AR425)135025 (AR435)

135053 (AR625)135025 (AR635)

AR825, 835132586A13275A

132752A

132713

135053 (AR825)135025 (AR835)

AR925, 935132586A13285A

132829A

13289

135053 (AR925)135025 (AR935)

Dimensions

Construction

A B C D E FG H J

Bracket dimensions

AR425/435AR625/635AR825/835AR925/935

80 98126160

145.5155216241

39.5437590

67 78110140

73 78.5 94.5 109.5

3 7 510

46.585

4852

8090

B24PB25P

Bracket partno.

Pressure gauge port sizePort sizeModel

1/4, 3/8, 1/23/4, 1

1 1/4, 1 1/22

1/41/41/41/4

AR425/435AR625/635

AR825/835AR925/935

Mounting/Adjustment

Exhaust valve assembly Note)

Main valve side diaphragm assemblyValve assembly

Valve springHandle

1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.<Lock operating method>Loosen the handle locking screw to unlock it, and tighten it to lock it.

2. Please contact SMC if this product is to be used between solenoid valve and actuator.

1. Install the valve guide (on the opposite side of the handle) 60 mm away from the ground surface to facil i tate maintenance inspection.

2. Do not use the regulator with flow exceeding the Max. flow indicated in “Flow Characteristics” as this can cause failure in pressure adjustment.

Be sure to read before handling.Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Relief port

Bleed port

Handle locking screw

Pressure gauge port size Pressure gauge port sizePressure gauge

(Option)

Port size

Bracket(Option)

Pressure gauge

(Option)

Port size

When handle !0 is turned clockwise to compress pressure adjustment spring i, the pressure from the IN side passes through diaphragm !1, opens pilot valve !2, and enters upper pilot chamber !3. This pressure and the force generated by pressure adjustment spring i act as resistance, resulting in equilibrium. Then, this pressure passes through diaphragm y of the main valve and stem !4, and pushes valve (main valve) u open, thus guiding the pressure to the OUT side. At the same time, the pressure passes through feedback hole !5, and enters diaphragm chamber !6, thus establishing the OUT side pressure (outlet pressure).

Precautions

Caution

14-4-17

Pilot Operated Regulator Series AR425 to 935

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-18

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Individual supply

Common supply

Common supply Individual supply Single unit Front handle

KCOLHSUP

SMC

KCOLHSUP

SMC

SMCSMC

KCOLHSUP

SMC

SMC

Upper space is limited.

KCOLHSUP

SMC

KCOLHSUP

SMC

0.5

0.10.3

IS1000MPa

0.6

0.20.4

SMCMADE IN JAPAN

SMCSMC

KCOLHSUP

SMC

SMC

Lower space is limited.

Front handle/Bottom ported Front handle/Top ported

• Handle position: Top, Front, Bottom• Piping direction: Top ported, Bottom ported• One-touch fitting types: Straight, Elbow

IN side

OUT side

Straight, Elbow

Straight, Elbow

4 6 8 10

Applicable tubing O.D. (mm)Fitting type

Also available in inch sizes.

Installation example

IN side

OUT side

Common exhaust type and individual exhaust type can be mounted on the same manifold base.(Available as Simple Specials)

Opening and closing lens cover makes adjustment easy.

Reverse flow function is equipped as a standard.Reverse flow function is equipped as a standard.Can control thrust of the actuator.

The mounting position of the supply block can be selected from the right, left and both sides of the manifold.

Example of panel mounting

Manifold type Single unit type

Front handle type is newly added to the single unit specifications.

With 3-way pressurerelief valve

With pressure switchWith 3-way pressure reliefvalve + Pressure switch

Supply block

Allows high degree of freedom in selection according to the installation conditions.Allows high degree of freedom in selection according to the installation conditions. Four types of supply blocks (for common supply)Four types of supply blocks (for common supply)

Types and sizes of the One-touch fittings can be changed.Types and sizes of the One-touch fittings can be changed.

Mixed manifoldMixed manifold

Pressure gauge with limit indicator.Pressure gauge with limit indicator.

Compact Manifold Regulator

Series ARM10/11

14-4-19

How to Order

ARM11A 1A 1 A Z107

ABC

Top

Front

Bottom

Inch size123456789M

1 station

2 stations

3 stations

4 stations

5 stations

6 stations

7 stations

8 stations

9 stations

10 stations

2. IN/OUT piping position

Symbol

1234

IN side

Bottom

••

Top

••

Bottom

Top

••

OUT side

Symbol

575859606162697071727374767778798081838485868788

IN side

Straight

ø1/4

••

••

ø5/16

••

••

ø3/8

••

••

ø5/16

••

••

ø1/4

••

••

ø3/8

••

••

ø5/32

•••

•••

ø1/4

•••

•••

ø5/32

••••••

ø1/4

••••••

Elbow Straight Elbow

OUT side

Note) When the handle and the OUT piping are located on the same side, the elbow fitting is directed to the rear side (DIN rail side).

Handle position: TopOUT piping position: Top

Handle position: BottomOUT piping position: Bottom

Front side(Pressure

gauge side)

Rear side(DIN rail side)

Front side(Pressure

gauge side)

Rear side(DIN rail side)

Symbol

070809101112192021222324262728293031333435363738

IN side

Straight

ø6

••

••

ø8

••

••

ø10

••

••

ø8

••

••

ø6

••

••

ø10

••

••

ø4

•••

•••

ø6

•••

•••

ø4

••••••

ø6

••••••

Elbow Straight Elbow

OUT sideNote)

1 2 3 4 5 6 7

FrontTopTop

Bottom IN side fittingElbow

OUT side fittingElbow

IN side fittingStraight

OUT side fittingStraight

1. Handle position

3. Regulator block stations 4. IN/OUT fitting type (Refer to the figure below.)

Metric size

Bottom

Top

Bottom

Compact Manifold Regulator Common Supply Type

Series ARM11A

14-4-20

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Specifications

Electric Circuit

Set Pressure Range

Manifold (Regulator block, Common supply block, 3-way valve common supply block)

Direct acting

Diaphragm regulator

Relief type

Non-relieving type

Within (Unbalance type)

ø6, ø8, ø10, ø1/4, ø5/16, ø3/8

ø4, ø6, ø5/32, ø1/4

1.5 MPa

1.0 MPa

0.05 to 0.7 MPa

0.05 to 0.35 MPa (Low pressure type)

Air

5 to 60°C

Regulator construction

Working principal

Relief mechanism

Backflow function

IN side tubing O.D.

OUT side tubing O.D.

Proof pressure

Maximum operating pressure

Set pressure range

Fluid

Ambient and fluid temperature

Standard

Optional

Standard

Optional

Pressure switch (Common supply block with pressure switch, 3-way valve common supply block + Pressure switch block)

Reed switch mechanism

Reed switch mechanism

1a

Piston mechanism (with magnet installed)

Grommet type

0.5 m

1.0 MPa

0.7 MPa

0.1 to 0.6 MPa

0.08 MPa

±0.05 MPa

Air

–5 to 60°C

AC 2 VA, DC 2 W

48 V

40 mA

30 G

Contact mechanism

Contact structure

Contact configuration

Reed switch operating mechanism

Wiring specifications

Wiring length

Proof pressure

Maximum operating pressure

Set pressure range

Hysteresis

Repeatability

Fluid

Ambient and fluid temperature

Maximum switching capacity

Operating voltage AC/DC

Maximum operating current and range

Impact resistance

24 V or less

50 mA

100 V

20 mA

Up to 100 VAC/VDC

0

0.1

0.2

0.3

0.5

0.4

0.1 0.2 0.3 0.4Pressure setting scale

Ope

ratin

g pr

essu

re M

Pa

Hys

tere

sis

ON pressure OFF pressure

Common supply block Common supply blockwith pressure switch

3-way valve commonsupply block

3-way valve commonsupply block

+Pressure switch block

L side L side

L side L side

Note) When the regulator is used with backflow, operate at a set pressure of 0.1 MPa or above.

5. Accessory

Symbol

NilABCDEFGHJKLMNOPQR

••••••••• •••••••••

••

••••

••••

••••

••••

Pressure gauge

NoneWith

pressuregauge

Commonsupplyblock

Commonsupply

block withpressureswitch

3-wayvalve

commonsupplyblock

3-way valvecommon

supply block

Pressureswitchblock

L side(Left)

R side(Right)

B side(Both)

Supply block type Supply block mounting position

+

Symbol

Nil1234567

None

•0.35 MPa

setting Note 1)

•••

Note 2)Non-relieving

••••

Oil-free

••••

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

6. Option

7. Unit representation

Symbol

NilZ Note)

DescriptionDisplay unit for product name plate and pressure gauge: MPa

Display unit for product name plate and pressure gauge: PSI

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI.

JIS Symbol

IN

OUT

OUT

Lead

sw

itch

Note 1) Pressure gauges are not available with the copper-free specification.

Note 2) The oil-free specification is not available for pressure switches.

14-4-21

Series ARM11ACompact Manifold RegulatorCommon Supply Type

Flow Characteristics

ARM11AA1-307 (One-touch fittings: IN ø6, OUT ø4) ARM11AA1-307-1 (One-touch fittings: IN ø6, OUT ø4)

Pressure Characteristics

ARM11AA1-307-1ARM11AA1-307

ARM11AA1-310 (One-touch fittings: IN ø8, OUT ø6) ARM11AA1-310-1 (One-touch fittings: IN ø8, OUT ø6)

ARM11AA1-312 (One-touch fittings: IN ø10, OUT ø6) ARM11AA1-312-1 (One-touch fittings: IN ø10, OUT ø6)

0

0.1

0.2

0.3

0.4

0.5

0.60.7

0 50 100 150

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.000 20 40 60 80 100

0

0.1

0.2

0.3

0.4

0.5

0.60.7

0 50 100 150 200 250 3000.00

0.05

0.10

0.15

0.20

0.25

0.300.35

0 50 100 150 200

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 50 100 150 200 250 3000.00

0.05

0.10

0.15

0.20

0.25

0.300.35

0 50 100 150 200

0.10

0.15

0.20

0.25

0.30

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.00.10

0.15

0.20

0.25

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Conditions: Inlet pressure 0.5MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Conditions: Inlet pressure 0.7MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Flow rate �/min(ANR) Flow rate �/min(ANR)

Flow rate �/min(ANR) Flow rate �/min(ANR)

Flow rate �/min(ANR) Flow rate �/min(ANR)

Inlet pressure MPa Inlet pressure MPa

Set point

Set point

14-4-22

Series ARM11A

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Construction

Body for regulator block

Bonnet

Handle

Valve seat

Adjusting screw assembly

Adjustment spring

Regulator clip

Manifold block

Blanking plate assembly

Square nut

Common exhaust bushing

No. Material

PBT

PBT

POM

POM

Reinforced steel

Steel wire

Stainless steel

PBT

Steel

POM

Component Parts

Diaphragm assembly

Valve

Valve spring

Gasket

O-ring

O-ring

O-ring

O-ring

Fitting assembly

Port plug

No. Material

Weatherproof NBR, POM

HNBR, Aluminum alloy

Stainless steel

HNBR

NBR

NBR

NBR

NBR

PBT/HNBR

Part no.

136126A

136127-30

136131

136137-30

136146

136147

136148

136149

Refer to page 14-4-37.

Refer to page 14-4-38.

Replacement Parts

A-AA

OUTIN

KCOLHSUP

SMC

SMC

K

A

11

J

H

3

6

4

F

E

B

1

C

G

9

10

5

2

A

8

D

7

Description Description

q

w

e

r

t

y

u

i

o

!0

!1

��

��

��

��

��

��

��

14-4-23

Series ARM11ACompact Manifold RegulatorCommon Supply Type

Dimensions

ARM11AA1-�12Handle position: Top/Common supply block

ARM11AA1-�12-AHandle position: Top/Common supply block with pressure switch

5333

.5

14

5718

L2

611.58

5.3

84

56

52.539

L2-10.5

5.5

L1=(28 x n)+5618 20 2828

53

14

33.5

18L2

11.5 6

5.3

84

2828

52.5393

5

28

L2-10.55.

5

8

L1=(28 x n)+5618 20 28

SMC

OUTINOUTIN

SMCSMC

0.50.10.3

MPa

0.60.20.4

IN

SMC

OUTININ OUTIN

SMC

SMC SMC

DIN rail part no. (for L and R sides)

AXT100-DR-9

AXT100-DR-11

AXT100-DR-13

AXT100-DR-16

AXT100-DR-18

AXT100-DR-20

AXT100-DR-22

AXT100-DR-25

AXT100-DR-27

AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no. (for L and R sides)

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

3935

35

14-4-24

Series ARM11A

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

ARM11AA1-�12-BHandle position: Top/3-way valve common supply block

ARM11AA1-�12-CHandle position: Top/3-way valve common supply block + Pressure switch block

DIN rail part no. (for L and R sides)

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no.

AXT100-DR-11AXT100-DR-13AXT100-DR-15AXT100-DR-17AXT100-DR-19AXT100-DR-22AXT100-DR-24AXT100-DR-26AXT100-DR-28AXT100-DR-31

Stations

123456789M

L2 dimension

148

173

198

223

248

285.5

310.5

335.5

360.5

398

14

535133

.518

6

3

11.5

L2

5.3

84

56

52.539

2218

L2-10.55.

5

8

L1=(28 x n)+582828

IN

SM

C

OUTIN

SMC

OUTIN

SMC

5333

.5

14

57 5118

3611.5

L2

5.3

84

56

52.539

202218

L2-10.5

5.5

8

L1=(28 x n)+782828

IN

SM

C

0.50.10.3

MPa

0.60.20.4

OUTINOUTIN

SMC SMC

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

35

35

35

28

28

14-4-25

Series ARM11ACompact Manifold RegulatorCommon Supply Type

35

35

Dimensions

ARM11AB1-�12Handle position: Front/Common supply block

ARM11AB1-�12-AHandle position: Front/Common supply block with pressure switch

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

18 14 33.5

L2

11.5

5.3

2856

52.581

28

L2-10.5

5.5

8

L1=(28 x n)+5618 20 28

KCOLHSUP

SMC

KCOLHSUP

SMC

OUT IN OUT INS

MC

SMC

IN

SMC

SMC

14

81

33.5

5718

L2

11.5

5.3

28

52.5

56

28

L2-10.5

5.5

8

L1=(28 x n)+5618 20 28

KCOLHSUP

SMC

KCOLHSUP

SMC

OUT IN OUT IN

SMC

SM

C

0.50.10.3

0.60.20.4

SMC

IN

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

53

14-4-26

Series ARM11A

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

ARM11AB1-�12-BHandle position: Front/3-way valve common supply block

ARM11AB1-�12-CHandle position: Front/3-way valve common supply block + Pressure switch block

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no.

AXT100-DR-11AXT100-DR-13AXT100-DR-15AXT100-DR-17AXT100-DR-19AXT100-DR-22AXT100-DR-24AXT100-DR-26AXT100-DR-28AXT100-DR-31

Stations

123456789M

L2 dimension

148

173

198

223

248

285.5

310.5

335.5

360.5

398

14

33.5

5118

L2

11.5

5.3

5628

52.581

28 2822

L2-10.5

5.5

8

L1=(28 x n)+5818

KCOLHSUP

SMC

KCOLHSUP

SMC

IN

SM

C

OUT IN OUT IN

SMCSMC

57 5118 14

33.5

L2

11.5

5.3

28

52.581

56

2218 28

L2-10.5

5.5

8

L1=(28 x n)+7820 28

KCOLHSUP

SMC

KCOLHSUP

SMC

SM

C

IN OUT INOUT IN

0.5

0.10.3

MPa

0.6

0.20.4

SMCSMC

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

35

35

14-4-27

Series ARM11ACompact Manifold RegulatorCommon Supply Type

Dimensions

ARM11AC2-�12Handle position: Bottom/Common supply block

ARM11AC2-�12-AHandle position: Bottom/Common supply block with pressure switch

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

5333

.518

14

11.5

L2

5.3

84

56

52.5392828

L2-10.55.

5

8

L1=(28 x n)+5618 20

SM

C

OUT IN

KCOLHSUP

SMC

OUT IN

KCOLHSUP

SMC

SMC

IN

SMC

SMC

5718

5333

.5

14

11.5

L2

5.3

84

56

52.539

L2-10.5

5.5

8

L1=(28 x n)+5618 20 2828

SM

C

OUT IN

KCOLHSUP

SMC

OUT IN

KCOLHSUP

SMC

SMCSMC

0.5

0.10.3

MPa

0.6

0.20.4

IN

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

28

28

3 53 5

14-4-28

Series ARM11A

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-29

Series ARM11ACompact Manifold RegulatorCommon Supply Type

ARM11AC2-�12-BHandle position: Bottom/3-way valve common supply block

ARM11AC2-�12-CHandle position: Bottom/3-way valve common supply block + Pressure switch block

DIN rail part no.

AXT100-DR-9 AXT100-DR-11AXT100-DR-13AXT100-DR-16AXT100-DR-18AXT100-DR-20AXT100-DR-22AXT100-DR-25AXT100-DR-27AXT100-DR-29

Stations

123456789M

L2 dimension

123

148

173

210.5

235.5

260.5

285.5

323

348

373

DIN rail part no.

AXT100-DR-11AXT100-DR-13AXT100-DR-15AXT100-DR-17AXT100-DR-19AXT100-DR-22AXT100-DR-24AXT100-DR-26AXT100-DR-28AXT100-DR-31

Stations

123456789M

L2 dimension

148

173

198

223

248

285.5

310.5

335.5

360.5

398

5118

5333

.5

14

L2

11.5

5.3

84

56

28

52.5392218

L2-10.55.

5

8

L1=(28 x n)+582828

IN

SM

C

OUT IN

KCOLHSUP

SMC

OUT IN

KCOLHSUP

SMC

SMCSMC

8

57 5118

5333

.5

14

L2

11.5

5.3

84

56

52.539

202218

L2-10.5

5.5

L1=(28 x n)+782828

IN

SM

C

OUT IN

KCOLHSUP

SMC

OUT IN

KCOLHSUP

SMC

0.5

0.10.3

MPa

0.6

0.20.4

SMCSMC

For the dimensions of One-touch fittings and manifold options, please refer to pages 14-4-34 to 14-4-38.

28

3 53 5

How to Order

JIS Symbol

ARM11B 1A 1 1 Z

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

06

1. Handle position

6. Option

5. Accessory

3. Regulator block stations

4. IN/OUT fitting type

Metric size

123456789M

1 station

2 stations

3 stations

4 stations

5 stations

6 stations

7 stations

8 stations

9 stations

10 stations

2. IN/OUT piping position

Symbol

565758686970757677828384

IN side

ø5/32

ø1/4

••

••

ø5/32

ø5/32

••

••

ø1/4

••

••

ø1/4

ø5/32

••••

ø1/4

••

Straight ElbowStraight Elbow

OUT side

Note) When the handle and the OUT piping are located on the same side, the elbow fitting is directed to the rear side (DIN rail side).

NilA

Note) Pressure gauges are not available with the copper- free specification.

Without pressure gauge

With pressure gauge

OUT

IN

IN

OUT

IN/OUT: Bottom IN/OUT: TopIN: BottomOUT: Top

IN: TopOUT: Bottom

Handle position: TopOUT piping position: Top

Handle position: BottomOUT piping position: Bottom

Front side(Pressure

gauge side)

Rear side(DIN rail side)

Front side(Pressure

gauge side)

Rear side(DIN rail side)

Symbol

060708181920252627323334

IN side

ø4

ø6

••

••

ø4

ø4

••

••

ø6

••

••

ø6

ø4

••••

ø6

••

StraightStraight Elbow

OUT side

7. Unit representation

1 2 3 4 5 6 7

Inch size

INOUT OUTIN

IN INOUT OUT

ABC

Top

Front

Bottom

FrontTop Bottom Symbol

1234

IN side

Bottom

••

Top

••

Bottom

Top

••

OUT side

Elbow Note)

Symbol

Nil1234567

None

•0.35 MPasettingNote 1)

•••

Note 2)Non-relieving

••••

Oil-free

••••

Symbol

NilZ Note)

DescriptionDisplay unit for product name plate and pressure gauge: MPa

Display unit for product name plate and pressure gauge: PSINote) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)

A

Compact Manifold Regulator Individual Supply Type

Series ARM11B

14-4-30

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Construction

Description

Body for regulator block

Bonnet

Handle

Valve seat

Adjusting screw assembly

Adjustment spring

Regulator clip

Manifold block

Blanking plate assembly

Square nut

Individual supply bushing

No. Material

PBT

PBT

POM

POM

Reinforced steel

Steel wire

Stainless steel

PBT

Steel

POM

Component Parts

Specifications

Direct acting

Diaphragm regulator

Relief type

Non-relieving type

Within (Unbalance type)

ø4, ø6, ø5/32, ø1/4

ø4, ø6, ø5/32, ø1/4

1.5MPa

1.0MPa

0.05 to 0.7MPa

0.05 to 0.35MPa (Low pressure type)

Air

5 to 60°C

Regulator construction

Working principal

Relief mechanism

Backflow function

IN side tubing O.D.

OUT side tubing O.D.

Proof pressure

Maximum operating pressure

Set pressure range

Fluid

Ambient and fluid temperature

Standard

Optional

Standard

Optional

OUTIN

KCOLHSUP

SMC

A

A

SMC

Description

Diaphragm assembly

Valve

Valve spring

Gasket

O-ring

O-ring

O-ring

O-ring

Fitting assembly

Port plug

No. Material

Weatherproof NBR, POM

HNBR, Aluminum alloy

Stainless steel

HNBR

NBR

NBR

NBR

NBR

PBT/HNBR

Part no.

136126A

136127-30

136131

136137-30

136146

136147

136148

136149

Refer to page 14-4-37.

Refer to page 14-4-38.

Replacement Parts

A-A

Note) When the regulator is used with backflow, operate at a set pressure of 0.1 MPa or above.

!1

q

o

e

y

r �

t

w

i

!0

u

q

w

e

r

t

y

u

i

o

!0

!1

��

��

��

��

��

��

��

14-4-31

Series ARM11BCompact Manifold RegulatorIndividual Supply Type

Flow Characteristics

ARM11BA1-306 (One-touch fittings: IN/OUT ø4) ARM11BA1-306-1 (One-touch fittings: IN/OUT ø4)

Pressure Characteristics

ARM11BA1-306 ARM11BA1-306-1

ARM11BA1-307 (One-touch fittings: IN ø6, OUT ø4) ARM11BA1-307-1 (One-touch fittings: IN ø6, OUT ø4)

ARM11BA1-308 (One-touch fittings: IN/OUT ø6) ARM11BA1-308-1 (One-touch fittings: IN/OUT ø6)

0.7

0.6

0.5

0.4

0.3

0.2

0.1

00 10050 150

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.000 20 40 60 80 100

0.7

0.6

0.5

0.4

0.3

0.2

0.1

00 10050 150

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.000 20 40 60 80 100

0.7

0.6

0.5

0.4

0.3

0.2

0.1

00 100 200 300

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.000 50 100 150 200

0.30

0.25

0.20

0.15

0.100.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

0.25

0.20

0.15

0.10

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Flow rate �/min(ANR) Flow rate �/min(ANR)

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Flow rate �/min(ANR) Flow rate �/min(ANR)

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Flow rate �/min(ANR) Flow rate �/min(ANR)

Conditions: Inlet pressure 0.5MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Conditions: Inlet pressure 0.7MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Inlet pressure MPa Inlet pressure MPa

Set point

Set point

14-4-32

Series ARM11B

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-33

Series ARM11BCompact Manifold RegulatorIndividual Supply Type

Dimensions

ARM11BA1-�08Handle position: Top

DIN rail part no.

AXT100-DR-8

AXT100-DR-10

AXT100-DR-12

AXT100-DR-14

AXT100-DR-16

AXT100-DR-19

AXT100-DR-21

AXT100-DR-23

AXT100-DR-25

AXT100-DR-28

Stations

123456789M

L2 dimension

110.5

135.5

160.5

185.5

210.5

248

273

298

323

360.5

ARM11BB1-�08Handle position: Front

DIN rail part no.

AXT100-DR-8

AXT100-DR-10

AXT100-DR-12

AXT100-DR-14

AXT100-DR-16

AXT100-DR-19

AXT100-DR-21

AXT100-DR-23

AXT100-DR-25

AXT100-DR-28

Stations

123456789M

L2 dimension

110.5

135.5

160.5

185.5

210.5

248

273

298

323

360.5

ARM11BC2-�08Handle position: Bottom

DIN rail part no.

AXT100-DR-8

AXT100-DR-10

AXT100-DR-12

AXT100-DR-14

AXT100-DR-16

AXT100-DR-19

AXT100-DR-21

AXT100-DR-23

AXT100-DR-25

AXT100-DR-28

Stations

123456789M

L2 dimension

110.5

135.5

160.5

185.5

210.5

248

273

298

323

360.5

33.5

16

5314

1212

L2

11.5

3

5.3

84

56

52.539

28

L2-10.5

5.5

8

L1=(28 x n)+3618 28

SM

C

OUTIN

SMC

OUTIN

SMC

33.5

14

8116

1212

L2

11.58

5.3

356

28

52.528

L2-10.5

5.5

L1=(28 x n)+3618 28

KCOLHSUP

SMC

KCOLHSUP

SMC

OUT IN OUT IN

SMC SMC

SM

C

33.5

14 1653

1212

L2

3

11.58

5.3

84

56

52.53928

L2-10.5

5.5

L1=(28 x n)+3618 28

SM

C

OUT IN

KCOLHSUP

SMC

OUT IN

KCOLHSUP

SMC

SMCSMC

Compact Manifold RegulatorOption

Common Supply Type

Individual Supply Type

L side end

block

L side end

block

DIN rail

DIN rail

One-touch fitting for common supply block

Regulator block

Regulator block

One-touch fitting for regulator block

One-touch fitting for regulator block

Port plug

Common supply bushing

Common supply block

Pressure switch block

Pressure gauge

Pressure gauge

R side end block

R side end block

Individual supply bushing

14-4-34

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

ARM11A 1A R 1041. Handle position

5. Option4. Accessory

ABC

TopFront

Bottom

3. OUT fitting type

Metric size

2. OUT piping position

12

Regulator Block

Common supply type

Handle position Top Handle position BottomHandle position Front

BottomTop

Symbol

54556667

ø5/32

•ø1/4

•ø5/32

•ø1/4

Straight ElbowSymbol

04051617

ø4

•ø6

•ø4

•ø6

Straight Elbow

NilA

Note) Pressure gauges are not available with the copper-free specification.

Without pressure gaugeWith pressure gauge Symbol

Nil1234567

None

•Non-

relieving

••••

Oil-free

••••

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non- greased fluid contact areas.

0.35 MPasetting Note 1)

••••

ARM11B 1A R 1061. Handle position

5. Option

4. Accessory

Individual supply type

NilA

Note) Pressure gauges are not available with the copper-free specification.

Without pressure gaugeWith pressure gauge

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

13

6

3 28

51.5

8470

OUTIN

SM

C

13 1512

3

5642

80

28.5

OUT IN

KCO

LH

SUP

SM

C

SM

C

15 1312

3 28

51.5

8470

OUTIN

SM

C

2. IN/OUT piping position

Symbol

1234

IN sideBottom

••

Top

••

Bottom

••

Top

••

OUT side

3. IN/OUT fitting type

Metric size Inch size

Symbol

565758686970757677828384

IN side

ø5/32

ø1/4

••

••

ø5/32

ø5/32

••

••

ø1/4

••

••

ø1/4

ø5/32

••••

ø1/4

••

Straight ElbowStraight ElbowOUT side

Symbol

060708181920252627323334

IN side

ø4

ø6

••

••

ø4

ø4

••

••

ø6

••

••

ø6

ø4

••••

ø6

••

Straight ElbowStraight ElbowOUT side

136

3

51.5

847026(Max.28)

OUT IN

SM

C

136

3

51.5

847026(Max.28)

OUT IN

SM

C

6

13

3

5642

80

OUT IN

KCO

LH

SUP

SM

C

SM

C

28.5

Z

Z

6. Unit representation

Symbol

Nil

ZDisplay unit for product name plate and pressure gauge: PSI

Display unit for product name plate and pressure gauge: MPa

Description

6. Unit representation

1 2 3 4 5 6

1 2 3 4 5 6

Inch size

Handle position Top Handle position Front Handle position BottomABC

TopFront

Bottom

Symbol

Nil1234567

None

•Non-

relieving

••••

Oil-free

••••

0.35 MPasetting Note 1)

••••

A

A

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)

Symbol

Nil

Z Note)

Description

Display unit for product name plate and pressure gauge: PSI

Display unit for product name plate and pressure gauge: MPa

14-4-35

Series ARM11A/BCompact Manifold RegulatorCommon/Individual Supply Type

14-4-36

Series ARM11A/B

ARM11A 1 S 01

3. IN fitting type

Metric size

Common Supply Block

Pressure Switch Block

Common supply block (S) Common supply block with pressure switch (P)

3-way valve common supply block+

Pressure switch block (W)3-way valve common supply block (V)

1. IN piping position

12

Bottom

Top

5. Accessory

NilA

Note) Leave the field blank for types without pressure switch.

Pressure switch lead wire length: 0.5 m

Pressure switch lead wire length: 3.0 m

4. Option

Note) The oil-free type has non-greased fluid contact areas.

Nil3

None

Oil-free

2. Common supply block type

SPVW

Common supply block

Common supply block with pressure switch

3-way valve common supply block

3-way valve common supply block + Pressure switch block

Note) The oil-free specification is not available for P and W types of common supply blocks (types with pressure switch).

Symbol

515253636465

Straight

ø1/4

•ø5/16

•ø3/8

ø5/16

ø1/4

ø3/8

ElbowSymbol

010203131415

Straight

ø6

•ø8

•ø10

ø8

ø6

ø10

Elbow 5

2417

32.5

20

56

SM

C

5617

5

24 20

56

0.5 0.10.3

MP

a

0.6 0.20.4

5

26 22

56

5017

202456

56

0.5 0.10.3

MP

a

0.6 0.20.4

5617

5

46 4222

56

0.5 0.10.3

MP

a

0.6 0.20.4

ZA

ARM11AW

1. Accessory

NilA

Pressure switch lead wire length: 0.5 m

Pressure switch lead wire length: 3.0 m

ZA

2. Unit representation

6. Unit representation

DescriptionDisplay unit for product name plate: MPa

Display unit for product name plate: PSI

Symbol

NilZ Note)

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI.

Symbol

NilZ Note)

DescriptionDisplay unit for product name plate: MPa

Display unit for product name plate: PSI

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The pressure switch offers dual unit representation in MPa and PSI.

1 2

1 2

3 4 5 6

Inch size

3

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

DIN Rail

One-touch Fittings for Regulator Block One-touch Fittings for Common Supply Block

X

Y

6.5

X

XX

12.5

Y

NO.L

123

235.5

348

460.5

573

685.5

798

8110.5

9123

10135.5

NO.L

11148

12160.5

13173

14185.5

15198

16210.5

17223

18235.5

19248

20260.5

NO.L

21273

22285.5

23298

24310.5

25323

26335.5

27348

28360.5

29373

30385.5

NO.L

31398

32410.5

33423

34435.5

35448

36460.5

37473

38485.5

39498

40510.5

Note) Put an appropriate No. from the table below in the place of “n.” For the L dimension, please refer to “Dimensions.”

• When only DIN rail is required: DIN rail part no.

AXT100- DR - n

5.5

2535

L

1.25 P=12.5 5.25 7.5

L Dimension L=12.5 x n+10.5

X

337

Fitting size

ø4, ø5/32ø6

ø1/4

Y

19 19.522

Fitting size

ø4, ø5/32ø6

ø1/4

X

5 5 5.55

Fitting size

ø6ø8, ø5/16ø10, ø3/8

ø1/4

Y

20 23 26 20.5

X

11.511.511.5

X

19202219

Fitting size

ø6ø8, ø5/16ø10, ø3/8

ø1/4

VVQ1000 50A C4

Option

Fitting type

Fitting size

One-touchfittings for

regulator block

NilX17

None

Oil-free

NilL1

Straight

Elbow

C4C6N3N7

ø4ø6

ø5/32ø1/4

VVQ2000 51A C6

Option

Fitting type

Fitting size

One-touch fittingsfor regulator

NilX17

None

Oil-free

NilL1

Straight

Elbow

C6C8C10N7N9N11

ø6ø8ø10ø1/4ø5/16ø3/8

Straight type Elbow type Straight type Elbow type

14-4-37

Series ARM11A/BCompact Manifold RegulatorCommon/Individual Supply Type

End Block Pressure Gauge

Port Plug Bushing

VVQ0000 58A

Option

Single unit regulator / Port plug for regulator block

NilX17

None

Oil-free

ARM11EOption

SpecificationsEnd block type

End blockNil3

None

Oil-freeSymbol

LR

Mounting position

Left side

Right side

L

Note 1) Since the L side end block is oil-free, leave the field blank for it.

187

32.526

20

SM

C

2218

7

32.526

20

56 56

SM

C

L side end block R side end block

Part no.

GC3-4A-X2102

GC3-10A-X2102

GC3-P4A-X2102

GC3-P10A-X2102

Pressure gauge indication range

0 to 0.4 MPa

0 to 1.0 MPa

0 to 60 PSI

0 to 150 PSI

Indication unit

MPa

PSI

Part no.

136144-S

136144-K

Description

Common supply bushing

Individual supply bushing

Fluid

Ambient and fluid temperature

Display accuracy

Calibration angle

Limit indicator

Air

-5 to 60°C

±3%F.S. (Full Span)

230°

With limit indicator

8

15

12

A-AA

A8

15

12

A-AA

A

10

ø10

136144-S 136144-K

14.5

ø1.

5

6

17.5

28

28

OPEN

VCO

ER

14-4-38

Series ARM11A/B

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

How to Order

Specifications

ARM10 06 B Z1

Symbol

060708181920252627323334

IN side

Straight

ø4

ø6

••

••

ø4

ø6

••

••

ø4

••

••

ø6

ø4

••••

ø6

••

Elbow Straight Elbow

OUT side

Symbol

565758686970757677828384

IN side

Straight

ø5/32

ø1/4

••

••

ø5/32

ø1/4

••

••

ø5/32

••

••

ø1/4

ø5/32

••••

ø1/4

••

Elbow Straight Elbow

OUT side

Symbol

Nil1234567

None

•0.35 MPasettingNote 1)

•••

Note 2)Non-relieving

••••

Oil-free

••••

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

ARM10

Direct acting

Diaphragm regulator

Relief type

Non-relieving type

Within (Unbalance type)

ø4, ø6, ø5/32, ø1/4

ø4, ø6, ø5/32, ø1/4

1.5MPa

1.0MPa

0.05 to 0.7MPa

0.05 to 0.35MPa (Low pressure type)

Air

5 to 60°C

60g

Model

Regulator construction

Working principal

Relief mechanism

Backflow function

IN side tubing O.D.

OUT side tubing O.D.

Proof pressure

Maximum operating pressure

Regulating pressure range

Fluid

Ambient and fluid temperature

Weight

Standard

Optional

Standard

Optional

Straight

Elbow

Bracket

Panel nut

Pressure gauge

1. IN/OUT fitting type

Metric size Inch size

3. Option

Note 1) Note 2)

Symbol

NilBGP

BGGP

None

•Bracket

Pressure gauge

•••

Panel nut

(•)

•(•)

•Note 1) In case of a type with bracket, the panel nut is included.Note 2) Pressure gauges are not available with the copper-free specification.

2. Accessory

4. Unit representation

JIS Symbol

Relief type Non-relieving type

Symbol

NilZ Note)

DescriptionDisplay unit for product name plate and pressure gauge: MPa

Display unit for product name plate and pressure gauge: PSINote) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)

Note) When the regulator is used with backflow, operate at a set pressure of 0.1 MPa or above.

1 2 3 4

IN sideOUT side

IN side

OUT side

Regulator Single Unit Type

Series ARM10

14-4-39

14-4-40

Series ARM10

1. IN/OUT piping position

2. IN/OUT fitting type

Inch sizeMetric size

Note 1)

Note 3)

Note 2)

Symbol

NilB

GPBGGP

None

•Bracket

••

Pressure gauge

••••

Panel nut

(•)

(•)

••

Display cover

•Note 1) In case of a type with bracket, the panel nut is included.Note 2) Pressure gauges are not available with the copper-free specification.Note 3) Please note that the dimensions will be big when GPC is required.

3. Accessory

GPC

Panel nut

Display cover

ARM10F 0612

B31

14

Z5

Front handle type

Panel Display cover

Example of panel mounting

How to Order

IN side

IN side

OUT side

OUT side

Top Top

Bottom Bottom

Symbol

060708181920252627323334

IN side

Straight

ø4

ø6

••

••

ø4

ø6

••

••

ø4

••

••

ø6

ø4

••••

ø6

••

Elbow Straight Elbow

OUT side

Symbol

565758686970757677828384

IN side

Straight

ø5/32

ø1/4

••

••

ø5/32

ø1/4

••

••

ø5/32

••

••

ø1/4

ø5/32

••••

ø1/4

••

Elbow Straight Elbow

OUT side

Panel nut

Bracket

Pressure gauge

1234

SymbolIN side OUT side

Bottom Top Bottom Top

•• •

•••

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

4. Option

Symbol

Nil1234567

None

•0.35 MPasettingNote 1)

•••

Note 2)Non-relieving

••••

Oil-free

••••

5. Unit representation

Symbol

NilZ Note)

DescriptionDisplay unit for product name plate and pressure gauge: MPa

Display unit for product name plate and pressure gauge: PSI

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)

Specifications

ARM10F

Direct acting

Diaphragm regulator

Relief type

Non-relieving type

Within (unbalance type)

ø4, ø6, ø5/32, ø1/4

ø4, ø6, ø5/32, ø1/4

1.5MPa

1.0MPa

0.05 to 0.7MPa

0.05 to 0.35MPa (Low pressure type)

Air

5 to 60°C

72g

Model

Regulator construction

Working principal

Relief mechanism

Backflow function

IN side tubing O.D.

OUT side tubing O.D.

Proof pressure

Maximum operating pressure

Set pressure range

Fluid

Ambient and fluid temperature

Weight

Standard

Optional

Standard

Optional

Note) When the regulator is used with backflow regulator, operate at a set pressure of 0.1 MPa or above.

14-4-41

Series ARM10RegulatorSingle Unit Type

Flow Characteristics

ARM10F�-06ARM10-06 (One-touch fittings: IN/OUT ø4)

ARM10F�-06-1ARM10-06-1 (One-touch fittings: IN/OUT ø4)

Pressure Characteristics

ARM10F�-06ARM10-06

ARM10F�-06-1ARM10-06-1

ARM10F�-07ARM10-07 (One-touch fittings: IN ø6, OUT ø4)

ARM10F�-07-1ARM10-07-1 (One-touch fittings: IN ø6, OUT ø4)

ARM10F�-08ARM10-08 (One-touch fittings: IN/OUT ø6)

ARM10F�-08-1ARM10-08-1 (One-touch fittings: IN/OUT ø6)

0 50 100 150

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.000 20 40 60 80 100

0 50 100 1500.00

0.05

0.10

0.15

0.20

0.25

0.300.35

0 20 40 60 80 100

0.70.6

0.5

0.4

0.3

0.2

0.1

00 50 100 150 200 250 300

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0 50 100 150 200

0.10

0.15

0.20

0.25

0.30

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

0.10

0.15

0.20

0.25

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Condition:Inlet pressure 0.7MPa

Condition:Inlet pressure 0.5MPa

Conditions: Inlet pressure 0.5MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Conditions: Inlet pressure 0.7MPaOutlet pressure 0.2MPaFlow rate 20�/min (ANR)

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Out

let p

ress

ure

MP

a

Flow rate �/min(ANR) Flow rate �/min(ANR)

Flow rate �/min(ANR) Flow rate �/min(ANR)

Flow rate �/min(ANR) Flow rate �/min(ANR)

Inlet pressure MPa Inlet pressure MPa

Set point

Set point

14-4-42

Series ARM10

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Construction

Dimensions

Description No. Material

PBT

PBT

POM

POM

Reinforced steel

Steel wire

Stainless steel

Steel

Component Parts2

ø23

28

10.535

26(M

ax.2

8)

12

22

28

73.5 59

.5

42 Through hole for M3 ø3.2

SMC

KCOLHSUP

SMC

OUTIN

DescriptionNo. Material

Weatherproof NBR, POM

HNBR, Aluminum alloy

Stainless steel

NBR

NBR

NBR

Part no.

136126A

136127-30

136131

136146

136147

136148

Refer to page 14-4-45.

Replacement Parts

Diaphragm assembly

Valve

Valve spring

O-ring

O-ring

O-ring

Fitting assembly

Body

Bonnet

Handle

Valve seat

Adjusting screw assembly

Adjustment spring

Regulator clip

Blanking plate assembly

Square nut

ARM10- 0608

For dimensions and accessories of One-touch fittings, please refer to page 14-4-45.

25

Panel cutout dimensions

ARM10 ARM10F

Plate thickness: Max.2.1

w

��

i

o

e

t

y

r

u

q

i

w

t

e

y

r

o

q

u

q

w

e

r

t

y

u

i

o

��

��

��

��

��

��

14-4-43

Series ARM10RegulatorSingle Unit Type

14-4-44

Series ARM10

Dimensions

ARM10F1- 0608

ARM10F1- 06GPC08GPC

3758

ø20

28

5

7

15

26(Max.28)

34

�28

to 2

8.5

ø23

Plate thickness: Max.2.1

Panel cutout dimensions

12

INOUT34

�28

to 2

8.5

ø23

Plate thickness: Max.2.1

Panel cutout dimensions

3858

ø20

28

INOUT

7

156

26(Max.28)

�30

734

1462

MPa

1

0.8

0.60.4

0.2

0

OPEN

KCOLHSUPSMC

12

INOUT

4-R1 or less

4-R1 or less

INOUT

7

22

12

31

3414

62SMC

KCOLHSUP

SMC

Through hole for M3 ø3.2

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

One-touch fittingsfor regulator

Regulator/Single Unit TypeOption

Specifications

Pressure Gauge One-touch Fittings for Regulator

Pressure gauge indication range

0 to 0.4MPa

0 to 1.0MPa

0 to 60PSI

0 to 150PSI

Indication unit

MPa

PSI

Part no.

GC3-4A-X2101

GC3-10A-X2101

GC3-P4A-X2101

GC3-P10A-X2101

Panel Nut

Bracket

Air

-5 to 60°C

±3%F.S. (Full Span)

230°

With limit indicator

17g

Fluid

Ambient and fluid temperature

Display accuracy

Calibration angle

Limit indicator

Weight

VVQ1000-50A C4Fitting type

Nil

L1

Straight

Elbow

Fitting sizeC4

C6

N3

N7

ø4

ø6

ø5/32

ø1/4

OptionNil

X17

None

Oil-free

14.5

ø1.

5

6

17.5

28

28

OPEN

VCO

ER

Display Cover

136133

POM

1g

Part no.

Material

Weight

136134

Nickel plated steel

17g

Part no.

Material

Weight

136155

PBT

0.5g

Part no.

Material

Weight

ø27.8

4.5

27(Width across flats of

equilateral octagon)

36.5

4.5

16 11

4

(R)

6.5

2

40

30

ø22

R13.5

23

Fitting size

ø4, ø5/32

ø6

ø1/4

X

2

2

6

Fitting size

ø4, ø5/32

ø6

ø1/4

Y

21.5

22

24.5

X

10.5

10.5

10.5

Fitting size

ø4, ø5/32

ø6

ø1/4

X

7

7

11

Fitting size

ø4, ø5/32

ø6

ø1/4

Y

21.5

22

24.5

X

15.5

15.5

15.5

Straight type

Elbow type

Elbow type

Y

5.5

X

ARM10

Straight type

ARM10F

1�

30

X10

.5

Y

XX

14-4-45

Series ARM10FMade to Order Specifications:Please contact SMC regarding detailed specifications, dimensions and delivery.

Specifications

How to Order

Dimensions

Direct acting

Diaphragm regulator

Relief type

Non-relieving type

Within (Unbalance type)

ø4

ø7

1.5MPa

1.0MPa

0.05 to 0.7MPa

0.05 to 0.35MPa (Low pressure type)

Air

5 to 60°C

73g

Regulator construction

Working principal

Relief mechanism

Backflow function

IN/OUT air passage diameter

IN/OUT gasket sealing O.D.

Proof pressure

Maximum operating pressure

Set pressure range

Fluid

Ambient and fluid temperature

Weight

Standard

Optional

Standard

Optional

Note 1) Mounting bolts and O-rings (2 of each) are attached.Note 2) When the regulator is used with backflow, operate at a set pressure of 0.1 MPa or above.

ARM10F 1A1 2

Z X2013 For manifold

1. Accessory

Nil

A

Without pressure gauge

With pressure gauge

3. Unit representation

Symbol

NilZ Note)

Description

Display unit for product name plate and pressure gauge: MPa

Display unit for product name plate and pressure gauge: PSI

Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)

Symbol

Nil1234567

None

Note 1) A pressure gauge with a full span of 0.4 MPa is attached.Note 2) The oil-free type has non-greased fluid contact areas.

2. Option

Non-relieving

••••

37

22

58(M

ax.6

0)

9

15 5

31

62 3414

ø20

28

SMC

O-ring sizeø4 x 1.5W

Holding screwM3 x 0.5 x 20

IN OUT

INOUT

KCOLHSUP

SMC

Regulator single unit front handle type/ For manifold

0.35 MPasettingNote 1)

•••

Example

Need to prepare manifold base.

Note 2)

Oil-free

••••

14-4-46

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

1. Confirm the specifications.The products appearing in this catalog are designed for use only in compressed air systems.Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Please consult with SMC if fluid other than compressed air is to be used.

2. Do not use the products in this catalog as “safety accessories” stipulated in Art. 1, paragraph 2.1.3 and Art. 3, paragraph 1.4 of Pressure Equipment Directive (97/23/EC).The Pressure Equipment Directive defines a safety accessory as a device which is designed to prevent pressure equipment from exceeding the allowable limit values.

3. Confirm the regulating pressure range.Be sure to install safety devices if output pressure above the set range can lead to damage or malfunction of equipment on the outlet side.

4. Residual pressure relief without inlet pressure.In cases where the inlet pressure has been released while the outlet pressure is in a low-pressure setting state, it may not be possible to exhaust the outlet pressure (residual pressure relief). Provide a residual pressure relief circuit if reliable outlet pressure relief must be performed.

5. When used with a closed downstream circuit and balance circuit.Please contact SMC as there are cases in which the product cannot be used.

3. After inserting the tubing, pull it lightly to confirm that it will not come out. If the tubing is not inserted to the end, air leakage or disconnection may occur.

4. When piping, increase the length of the tubing to allow for any possible warping, increased tension or moment load, etc. to the fittings and tubing.

2) Tubing removal1. Push both the release bushing and flange.2. Pull out the tubing while holding the release bushing so that it

will not be locked again. Insufficient pressure on the release bushing will result in increased biting force that will impede the tubing removal.

3. When re-using a removable tubing, cut of the deformed part. If the deformed part of the tubing is used, it can cause air leakage or impede the tubing removal.

In cases where a tubing brand other than SMC is used, confirm that the tubing outside diameter accuracy satisfies the following specifications.

1. Nylon tubing ±0.1 mm or less2. Soft nylon tubing ±0.1 mm or less3. Polyurethane tubing +0.15 mm or less/–0.2 mm or lessDo not use the tubing if it does not satisfy the outside diameter accuracy. Tubing connection may be impossible or air leakage or tubing disconnection may occur after connection.

Design & Selection

Warning

Compact Manifold Regulator/Series ARM10/11Specific Product Precautions 1Be sure to read before handling.

1. Read the instruction manual carefully.The product should be mounted and operated with a good understanding of its contents. Also, keep the manual where it can be easily referred to at any time.

2. Ensure space for maintenance.Ensure the necessary space for maintenance activities.

3. Strictly observe the tightening torque of the screw.Tighten the screw at the recommended torque in installation.

Mounting

Warning

1. Use clean air.Do not use the regulator if the compressed air contains synthetic oil including chemicals or organic solvents, salt or corrosive gas. It may lead to damage or malfunction.

Air Supply

Warning

1. Install an air filter.Install an air filter on the inlet side in close proximity with the regulator. Select a type with 5 µm or smaller filtration.

2. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage.Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment.

3. If an excessive amount of carbon powder is generated, install a mist separator as a measure.If an excessive amount of carbon powder is generated from the compressor, it may adhere to the interior of the regulator and cause malfunction.

Refer to Best Pneumatics Vol. 14 for further details on compressed air quality.

Caution

Piping

Caution

Precautions in use of One-touch fittings1) Tubing installation1. Take a tubing with no flaws on its periphery and cut it off at a

right angle. Use a TK-1, 2 or 3 tubing cutter to cut the tubing. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. Also, ensure sufficient tubing length.

2. Hold the tubing and push it in slowly, inserting it securely all the way into the fitting.

Piping

Caution

14-4-47

Compact Manifold Regulator/Series ARM10/11Specific Product Precautions 2Be sure to read before handling.

Regulator

1. Set up the regulator while verifying the pressure that is indicated on the inlet side and outlet side pressure gauges. Turning the handle excessively could damage the internal parts.

2. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage.

Adjustment

Warning

1. Maintenance should be performed according to the procedure indicated in the instruction manual.Improper handling can cause damage and malfunction of equipment and machinery.

2. Maintenance operations.Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.

3. Pre-maintenance inspection.When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere.

4. Post maintenance inspection.After installation or repair, reconnect compressed air and electricity and conduct appropriate inspections to confirm proper operation. If there is an audible air leakage, or if the equipment does not operate properly, stop operation and confirm that the equipment is installed correctly.

5. Modification prohibited.Do not modify or reconstruct the unit.

Maintenance

Warning

Regulator

1. Set up the regulator after carefully verifying the pressure that is indicated on the inlet side pressure gauge.

2. Set the outlet pressure in a range that is within 85% of the inlet pressure.Also, it should not exceed the set pressure range.

3. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.

4. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counter-clockwise decreases the pressure. (To achieve the final set pressure, gradually increase from low pres-sure until the desired pressure is reached.)

Caution

Operating Environment

1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same.

2. In locations which receive direct sunlight, the sunlight should be blocked .

3. Do not operate in locations where vibration or impact occurs.

4. Do not operate in a location near a heat source or where radiated heat will be received.

WarningHow to adjust indicator of the pressure gauge.Make sure to follow the instruction when opening the lens cover to adjust the pressure gauge.

Adjustment

Caution

1. Open the lens cover to the arrow’s direction with finger nail.

2. Adjust the gauge needle with for example, a flat head screw driver.

3. Close the lens cover to the arrow’s direction until it snaps on.

CO

VER

OP

CO

VER To close the lens.

OPE

CO

VER

To open the lens.

14-4-48

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Observe the proper screw tightening torque in installation.Tightening beyond the proper tightening torque may damage the mounting screws, blocks or switches.If the force is below the tightening torque range, the threaded joint can come loose.

1. Tightening torque for fixing screws and panel nuts of a single unit regulator

Warning

2. Tightening torque for regulator assembly fixing screws on regulator block

3. Tightening torque for blanking plates and pressure gauge fixing screws on regulator block

One-touch fitting replacementFor the ease of replacement, One-touch fittings are installed as the cassette type. One-touch fittings are retained with clips inserted from the directions illustrated blow. Remove the clips with a flat head screw driver to replace the One-touch fittings. When installing, insert each One-touch fitting deeply to the end and reinsert the clip to the specified position.

1. Single unit regulator

Caution

Pressure supply of 3-way valve common supply blockMake sure that the handle is set at the OPEN or SHUT position in operation. The block cannot be used for the purpose of containing pressure because it allows a small amount of leakage.

Caution

2. Regulator block

3. Various common supply blocks

4. Tightening torque for pressure switch fixing screws on common supply block with pressure switch and pressure switch block

5. Tightening torque for DIN rail clamp screws on end block

Blocks/Series ARM10/11Specific Product PrecautionsBe sure to read before handling.

Handling

1±0.1N·m

0.32±0.03N·m

0.32±0.03N·m

0.32±0.03N·m

0.18±0.02N·m

1.5±0.15N·m 90°

OPEN

SHUT

14-4-49

1. Operate the switch only within the specified voltage.Use of the switch outside the range of the specified voltage can cause malfunction and damage to the switch, it may also increase the risks of electrical shocks or fire.

2. Never apply a load above the maximum load capacity.It can damage the switch or shorten the service life.

3. Be sure to observe the set pressure range and maximum operating pressure.Use of the switch outside the set pressure range can cause failure and use beyond the maximum operating pressure can damage the switch.

1. Connect the loadBe sure to connect the load to the pressure switch before connecting the power supply.

2. Use a contact protection box.If the load driven by the pressure switch is an induction load or connected with a lead wire of 5 m or longer, use a contact protection box in the following table.

WiringDesign & Selection

3. Contact protection box internal circuit

4. Contact protection box/Connection methodTo connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with “SWITCH” and the lead wire from the switch body.Connect the switch body and the contact protection box with a lead wire of 1 m or shorter and arrange them as close as possible.

5. Lead wire dimensionsCovering: ø3.4Insulator: ø1.1Conductor: ø0.64

Warning Warning

1. Never use in the presence of explosive gases.These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion.

2. Do not use in an environment where a strong magnetic field is present.The influence of the external magnetic filed may cause the switch to malfunction.

3. Do not use in an environment where the switch is exposed to water or oil splashes.Because the switch has an open type construction, ingress of water or oil can corrode the electric circuit, resulting in malfunction and damage.

4. Do not apply vibration to the switch.If vibration is applied, malfunction or setting errors may result.

Operating Environment

Warning

1. Do not use the switch unless the equipment operates normally.After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.

2. Do not apply a tensile force to a cord.Be sure to hold the body to handle the product.Applying a tensile force to a cord may cause damage to the product.

3. Do not drop or bump the product.Dropping or bumping while handling may cause damage to the product.

Mounting

Warning

1. Do not use the switch with corrosive gas or liquid.Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch.

2. Do not use the switch at a vacuum pressure.If used in a vacuum pressure range, the switch will suction the outer air and become unable to operate.

Pressure Supply

Warning

1. The switching setting indication scale shows the set value for pressure decrease.

2. When the ON pressure signal is to be detected, the ON signal comes on at the pressure found by adding the hysteresis to the pressure set on the scale plate.

3. The pressure indication on the scale plate is provided as a guideline. Use a pressure gauge to measure the precise settings.

Pressure Setting

Caution

Pressure Switches/Series ARM10/11Specific Product PrecautionsBe sure to read before handling.

Contact protection box

CD-P11CD-P12

Operating voltage

100V AC

24V DC

Lead wire length

Switch connection side: 0.5 m

Load connection side: 0.5 m

CD-P11Brown lead wire

Surge absorber

Blue lead wire

CD-P12Brown lead wire

Zener diode

Blue lead wire

Chokecoil

Chokecoil

14-4-50

14-4-51

F.R.L.

AV

AU

AF

AR

IR

IRV

VEX

AMR

ITV

VBA

VE�

VY1

G

PPA

M5 x 0.8

� Precautions—When drain or oil, etc. gets into the gauge, an error may occur for pressure indication.

Manifold Regulator

Series ARM1000/2000FluidProof pressureMaximum operating pressure

Regulating pressure range

Ambient and fluid temperatureFluidCracking pressure (Valve)Construction

Air1.2 MPa0.8 MPa

0.05 to 0.7 MPa0.2 MPa setting 0.05 to 0.2 MPa

–5 to 60°C (No freezing)Air

0.02 MPaRelieving type

Model PipingPort size Weight (g)

IN side OUT side Total weight (n: stations) Regulator (Except manifold)

ARM1000

ARM2000

Common INIndividual INCommon INIndividual IN

1 81 8

1 4

1 8

1 81 8

1 8

1 8

(80 x n) + 23 (79 x n) + 25 (188 x n) + 43 (187 x n) + 45

57

136

How to Order

Port Size/Weight

Standard Specifications

ARM1000-6A1-01G

ARM2000-4B2

ARM2000-4A2-01G

ARM 1000 A15 01 G 1Regulator for manifold

Body size

Numberof stations

Piping

Port size (OUT side)10002000

Thread type

1

···

1 station

10 10 stations

···

Symbol IN OUTA1A2B1B2

Common

Individual

Manifold sideBody side

Manifold sideBody side

NilN

RcNPT

Description

Common INIndividual IN

Manifold

Regulator main bodyARM2000

ARM2000A13622- ∗13623- ∗

ARM1000ARM1000A

13612- ∗13613- ∗

Note 3) When ordering single unit

01 81

AccessoryNilG

None (With plug)With pressure gauge

Option1 0.2 MPa setting

Option: Pressure Gauge: G15-10-01

How to Order

G15 10 01

Thread typeNilN

RcNPT

Max. display pressure10 1.0 MPa

Connectingthread

011/8 male thread, M5 female thread

Note 1) In the case of A1 and B1, a pressure gauge or a plug is mounted on the body side, while in case of A2 and B2, on the manifold side.

Note 2) When mounting a pressure gauge on the body side, its front faces the adjusting screw.

• “∗” in manifold part no. repersents the number of manifold stations of regulator.

Note 1) Use caution not to tighten excessively when mountinga pressure gauge, otherwise it may result in a breakdown. Tightening torque recommended (M5: 1.5 to 2 N·m, R1/8: 7 to 9 N·m) For sealing, use a pipe tape.

Note 4) When a regulator is not mounted on the manifold, use the following blank plate ass'y (with mounting screws and O-ring)For ARM1000: Part no. 136114AFor ARM2000: Part no. 136214A

IN

IN

Individual IN

OUT

OUT

JIS SymbolCommon IN

OUT

OUT

IN

Note 1) Pressure gauge for 1.0 MPa is used.

Note 2) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.

� 4 connection methods

� Small size pressure gauge ø15

� Backflow function available on the standard model

� Space-saving

∗ Not able to set the pressure excceding 1.0 MPa.

14-4-52

Lock nut

(Bod

y si

de)

(Manifold side)

Inlet pressure: 0.7 MPa

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR))

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR))

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa)

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa)

Initial set pointInitial set point

Initial set pointInitial set pointInitial set point

Flow Characteristics

Pressure Characteristics

No. NoteDescription Material

No.Part no.

Description Material

BodyManifoldValve guidePistonAdjusting springAdjusting screw

ValveValve springValve guideO-ringO-ring

Aluminum die-castedAluminum alloy

BrassBrass

Steel wireSteel

Brass, HNBRStainless steel

PolyacetalNBRNBR

Chromate treatedChromate treated

Zinc chromatedElectroless nickel plated

q

w

e

r

t

y

u

i

o

!0

!1

Component Parts

Replacement Parts

Construction (Individual IN)

ARM1000 ARM2000134819-30

1361513614

16.5 x 13.5 x 1.5JIS B 2401P7

13626-301362513624

23 x 20 x 1.5JIS B 2401P8

Setting

Warning1. In the case of the common IN style, supply pressure from the two IN ports from both ends.

Failure to observe this procedure could result in an excessive pressure drop.

Mounting/Adjustment

Maintenance

Caution

Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

1. Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between solenoid valve and actuator, etc. Sudden pressure changes could happen and the durability of the product could be reduced. Using an electronic style pressure gauge is recommended, depending on the situation.

1. Make sure to check the inlet pressure before setting the outlet pressure. Turning the pressure adjustment handle clockwise increases the outlet pressure and turing it counterclockwise decreases

the pressure. (To set the pressure, do so in the direction of pressure increase.)

2. Set the outlet pressure to 85% or less of the inlet pressure.

1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate. <Lock operating method>Loosen the lock nut to unlock it, and tighten it to lock it.

2. This product can be used as a regulator with a check valve by installing it between solenoid valve and actuator.

Precautions

Warning

(Initial setting) Inlet pressure: 0.7 MPaOutlet pressure: 0.2 MPaFlow rate: 10 � /min (ANR)

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

14-4-53

Pressure gauge(Option)

(With

pre

ssur

e ga

uge)

IN (Individual IN) IN (Common IN)

14.5

(W

ith p

ress

ure

gaug

e)Pressure gauge(Option)

(Mounting hole)

(Pitch)

IN (Common IN, with plug)

Dimensions

Model Symbol

ARM1000

ARM2000

ARM1000ARM2000

L1L2L1L2

136274839

255467667

37465

10495

49384

132123

5112103160151

6131122188179

7150141216207

8169160244235

9188179272263

10207198300291

Manifold stations (n)

A4.54.5

B25

34.5

C3443

D2128

E1827

F5670

G1620

H9

11.5

J1824

K1928

M5266

P9

11.5

Q11.516.5

R4.84.8

SymbolModel

Dimensions

Dimensions by the Number of Stations

14-4-54

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

ARM3000

ARM2500

How to Order

ARM 2500 05 A

Regulator for manifold

Body size

Number of stations

Piping

Port size (OUT side)25003000

02

Thread type

G1

02

···

2 stations

10 10 stations

···

Nil Rc

FN

GNPT

AccessoryNilG1G2

None (With plug)

Symbol

AB

Symbol Port size

0203

1/43/8

Applicable model

ARM2500ARM3000

TypeCommon INIndividual IN

INFrom end plate

From OUT port or G port

G33-10-�01GA33-10-�01

Standard Specifications

Port Size/Weight

Weight by the Number of Stations

Proof pressure

Maximum operating pressure

Regulating pressure range

Ambient and fluid temperature

Fluid

Construction

1.5 MPa

1.0 MPa

0.05 to 0.85 MPa

–5 to 60°C (No freezing)

Air

Relieving type

Model Piping

Port size Weight (kg)

IN sideOUT side

Pressuregauge

port size

ARM2500

ARM3000

Common IN

Individual IN

Common IN

Individual IN

BodyRegulator End plate

End plate

0.26 0.06

0.47 0.11

1 43 8

1 41 4

3 81 2

3 83 8

1 8

1 8

1 8

1 8

ARM2500

ARM3000

StationsModel 2 3 4 5 6 7 8 9 10

(kg)

0.68

1.25

0.96

1.75

1.23

2.25

1.51

2.75

1.78

3.26

2.06

3.76

2.33

4.26

2.61

4.76

2.89

5.26

Manifold RegulatorModular Style

Series ARM2500/3000

JIS SymbolCommon IN Individual IN

� A modular type that can be freely mounted on a manifold station.

� Optimal for central pressure control.

� Easily set up using the new handle. Also has a One-touch lock system.

∗ Pressure gauges are shipped together (but not assembled).

14-4-55

Width

acros

s flat

s 10

Caution

Model Part no. A

30

41

Composition of assemblySet nut (1349172)

Bracket (B220)

Set nut (131532)

Bracket (B320)

136314

136414

ARM2500

ARM3000

B

34

40

C

70

75.5

D

5.4

6.5

E

15.4

8

F

55

53

G

2.3

2.3

H

M33 x 1.5

M42 x 1.5

Option: Bracket Assembly Individual IN type can be used as a single unit regulator.

Model Part no.

136313136413

ARM2500ARM3000

Dimensions

Hexagon socket head cap screw (M5 x 70)

Hexagon socket head cap screw (M6 x 85)

Qty.

44

Note

With flat washer

With flat washer

Option: Pressure Gauge (Max. pressure indication: 1.0 MPa) Flow Characteristics

Option: Mounting Bolt Assembly

Inlet pressure: = 0.7 MPa

Pressure Characteristics

Initial settingP1 = 0.7 MPa P2 = 0.2 MPaQ = 20 �/min (ANR)

Mounting/Adjustment

Note) Tighten the set nut securely and fix it. Recommended torque for set nut ARM2500: 17.5 ± 3.5 N·m ARM3000: 22.5 ± 4.5 N·m

1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the secondary pressure to fluctuate.1) On the ARM2500 type, pull the adjustment

handle to release the lock and push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise before pushing it.

2) On the ARM3000 type, pull the adjustment handle to release the lock. (An orange colored line is provided at the bottom of the adjustment handle for visual checking.)

Push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise; then, push it until the orange colored line is no longer visible.

2. Make sure to check the inlet pressure before setting the pressure. The outlet pressure must be set to 85% or less of the inlet pressure. Failure to observe this procedure could cause the outlet pressure to fluctuate.

3. In the case of the common IN type, supply pressure from the two IN ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop.

Example of mounting

Bracket

Set nut

Out

let p

ress

ure

(MP

a)

Flow rate (�/min (ANR))

Out

let p

ress

ure

(MP

a)

Flow rate (�/min (ANR))

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa)

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa)

ARM3000

ARM2500

ARM3000

ARM2500

Note 1) � in the gauge part no. (e.g. G33-10-�01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter “N”.Please consult with SMC for the supply of a pressure gauge with NPT port threads.

Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it will may result in a breakdown. For sealing, use a pipe tape. Torque recommended: (R 1/8: 7 to 14 N·m).

G33-10-�01 GA33-10-�01

PrecautionsBe sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Series ARM2500/3000

14-4-56

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Component Parts

Replacement Parts

Component PartsNo.

No.

Description

No.

Part no.

Description

Assembly

Component Qty.

1

111

1

222

Material Note

Description MaterialPart no.

q

w

o

!0

!1

!2

!3

!2

!3

Body

Bonnet

Aluminum die-casted

Polyacetal

Chromate treated/Platinum silver painted

Weather resistant NBR

Brass, HNBR

Stainless steel

NBR

NBR

NBR

ARM2500 ARM3000

ARM2500 ARM3000

1349161A

13639A

136310

11.5 x 8.5 x 1.5

JIS B 2401 P3

28 x 25 x 1.5

131515A

13649A

136410

14.5 x 10.5 x 2

JIS B 2401 P5

35 x 31 x 2

Diaphragm assembly

Valve assembly

Valve spring

Valve O-ring

O-ring

O-ring

Regulator

End plate REnd plate L

O-ring

O-ring

ARM2500-A-02

ARM2500-B-02

ARM3000-A-03

13636A

136312 136412

13646A13636B(ExceptO-ring)

13646B(ExceptO-ring)

ARM3000-B-03

Common IN

Individual IN

Common IN

Individual IN

e

r

t

y

u

i

Regulator

End plateassembly

Bracketassembly

Construction

Bra

cket

Bra

cket

Bracket ABracket B

Hex. socket head cap

screw

Bracket ABracket B

Hex. socket head cap

screw

22

1set

1set 2

How to order(1) When adding n stations to ARM - ∗∗ • Regulator n pcs. • Bracket assembly n pcs.(2) When regulators, end plate assembly and bracket assembly are assembled to make the manifold of n stations. • Regulator n pcs. • Bracket assembly n pcs. • End plate assembly 1 pc.

25003000

AB

Common IN

Common IN Common IN

Individual IN

Individual IN Individual IN

14-4-57

Series ARM2500/3000Manifold Regulator Modular Style

Dimensions

ARM2500ARM3000

A

6

7

17

21

44

54

56

68

42

55

126.5

153.5

58

70

45

53

17

23.5

21

27.5

38

48.5

42

55

29

35

48

59

68

85.5

33.5

42.5

B C D E F G H I J K L M N O PSymbolModel

ARM2500

ARM3000

Symbol

L1

L2

L3

L1

L2

L3

118

106

84

152

138

110

2

160

148

126

207

193

165

3

202

190

168

262

248

220

4

244

232

210

317

303

275

5

286

274

252

372

358

330

6

328

316

294

427

413

385

7

370

358

336

482

468

440

8

412

400

378

537

523

495

9

454

442

420

592

578

550

10Model

Dimensions

Manifold stations

Dimensions by the Number of Stations

∗ For products with pressure gauge, pressure gauges are shipped together with product.

Pressure gauge (Option) Pressure gauge (Option)

(With

pre

ssur

e ga

uge)

Panel mounting hole

IN (Common IN)

IN (Individual IN)

Gauge port

Series ARM2500/3000

14-4-58

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Direct Operated Precision RegulatorModular Style

Series ARP3000

Port size

Fluid

Proof pressure

Maximum operating pressure

Regulating pressure range

Setting sensitivity

Repeatability

Air consumption Note)

Pressure gauge port size

Ambient and fluid temperature

Construction

Weight (kg)

Air

1.2 MPa

0.8 MPa

0.005 to 0.3 MPa

0.001 MPa

±0.003 MPa

4 to 6 �/min (ANR) (0.3 MPa)

–5 to 60°C (No freezing)

Bleed type

0.42

How to Order

Standard Specifications

Description

B320

G36-4- 01

Accessory (Option)/Part No.

ARP3000-02

ARP3000-02BG

ARP 3000 BG

Direct operated precision regulator

R02

Thread typeAccessory

OptionNone

Port size41

Pressure gauge (1)

Bracket

0.4 MPa

Part no.

Note) Air consumption differs depending on the set pressure.

( )

Model ARP300041

81

NilNF

RcNPT

G

02

BG

Nil NoneWith bracket

With pressure gauge

Nil

R

JIS Symbol

� Setting sensitivity: 0.001 MPa� Can be connected as a

module to a mist separator.AFM30 + ARP3000AFD30 + ARP3000

� Direct-driven, bleed type (With relieving function)

Note 1) • � in the gauge part no. indicates the threads used for connection. For Rc, leave the symbol blank, and for NPT, enter “N”'.

• Please contact SMC concerning the supply of NPT pressure gauges.Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise

it will may result in a breakdown. (Fastening torque recommended: 7 to 9 N·m.) For sealing, use a pipe tape.

∗ Pressure gauges are shipped together with regulator, (but not assembled).

Reverseflow

14-4-59

Dimensions

Construction

Set nut: Width across flats 50

No. Description Material Note

q

w

e

r

t

y

u

i

o

!0

Body

Bonnet

Aluminum die-casted

Aluminum die-casted

Platinum silver painted

Black painted

No. Description Material Part no.

Diaphragm assembly

Valve assemblyValve springValve mini Y packingO-ringO-ringHandleSet nut

Weather resistant NBR

Brass, HNBRStainless steel

NBRNBRNBR

PolyacetalZinc die-casted

1315510A

1315506A1315516-2

MYN-5JIS B 2401P6

1315451315513131532

Component Parts

Replacement Parts

CautionSelection Air Supply

Orange mark

1. Release the lock to adjust the pressure. After the adjustment, engage the lock.Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.1) Pull the adjustment handle to

release the lock. (An orange colored line is provided at the bottom of the adjustment handle for visual checking.) Push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or; then, push it until the orange colored line is no longer visible.

2) Install the valve guide (on the opposite side of the handle) 60 mm away from the ground surface.Maintenance and inspection will be facilitated.

3) Air is normally released from the bleed hole. This is necessary for direct-operated precision regulator construction.

4) Please contact SMC if this product is to be used between solenoid valve and actuator.

5) Fasten the main body with a set nut tightly and fix it.Recommended torque for set nut: 22.5 ± 4.5 N·m

1. Set the output pressure to 90% or less of the inlet pressure.Failure to observe this procedure could result in an excessive pressure drop.

1. Use a mist separator on the inlet side. If the air contains drain or debris, it could clog the bleed holes and lead to a malfunction.

2. Do not use a lubricator on the inlet side because it could clog the bleed holes and lead to a malfunction.

Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

JIS Symbol

Always bleeding

Panel mounting hole

Pressure gauge port size

Thickness max. 3.5

Pressure gauge(Option)

Port size

M42 x 1.5(Thread size)

Bracket(Option)

Pressure Characteristics

Flow Characteristics

Inlet pressure: 0.5 MPaOutlet pressure: 0.2 MPaFlow rate: 0 �/min (ANR)

Inlet pressure: 0.7 MPa

Out

let p

ress

ure

(MP

a)O

utle

t pre

ssur

e (M

Pa)

Inlet pressure (MPa)

Set pointSet point

Flow rate (�/min (ANR))

∗ For products with pressure gauge, pressure gauge is shipped together with product.

Precautions

Warning

Caution

Series ARP3000

14-4-60

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

��� ��� ���� ���� � ��� ���� ��������

Regulator for 2 MPa

Series ARX20

� Compatible with inlet supply pressure of 2.0 MPa

� Compact type (face to face dimensions 35 mm,

overall length 80 mm)

� Piston type

� 3 out ports for convenient use

� Employs a handle shape for easy operation

� Ideal for discharge pressure adjustment on a

small compressor

� Ideal for pressure adjustment of air blowing

applications

14-4-61

How to Order

RcNPT

G

1348112G36–10–01G46–10–02G36–4–01G46–4–02G36–P10–N01G46–P10–N02G36–P4–N01G46–P4–N021348110A

Bracket

None

Panel nut

∗ Panel nut is also included with B.

Note 1)

Nil

NF

Thread type

1/81/4

0102

BNil

G Pressure gauge

ARX20–N��

ARX21–N��

ARX20– ��NilF

ARX21– ��NilF

PPort size

0.05 to 0.85 MPa0.05 to 0.30 MPa

01

Regulating pressure range

Regulator for 2 MPa Option

Option combination numbers

Regulator for 2 MPa

Series ARX20

BGP

BGGP

ARX2 0 01

Specifications

ARX20

Piston type regulator

Relieving type

Rc 1/8, 1/4

Rc 1/8, 1/4

3.0 MPa

2.0 MPa

0.05 to 0.85 MPa

0.05 to 0.3 MPa

Air

–5 to 60°C (No freezing)

110 g

Regulator construction

Relief mechanism

Port size

Pressure gauge port size

Proof pressure

Maximum operating pressure

Regulating pressure range

Fluid

Ambient and fluid temperature

Weight

Standard type

Low pressure type

JIS Symbol

Note 1) Compared with ARX20, ARX21 is the product which adjusting spring has only been changed.

It is not the product, which does not allow the pressure more than 0.3 MPa.

Note 2) Pressure gauges are shipped together, (but not assembled).

(2)

Model

14-4-62

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Flow Characteristics

Pressure Characteristics

Inlet pressure: 2.0 MPa

Inlet pressure: 2.0 MPaOutlet pressure: 0.3 MPaFlow rate: 60 � /min (ANR)

Inlet pressure: 2.0 MPaOutlet pressure: 0.8 MPaFlow rate: 60 � /min (ANR)

ARX20-01

ARX21-01 ARX21-02

ARX20 ARX21

ARX20-020.900.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

00 100 200 300 400 500 600 700 800 900 1000

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

Flow rate (� /min (ANR)) Flow rate (� /min (ANR))

Flow rate (� /min (ANR)) Flow rate (� /min (ANR))

0.35

0.30

0.25

0.20

0.15

0.10

0.05

00 50 100 150 200 250 300 350 400 450 500

Out

let p

ress

ure

(MP

a)

Out

let p

ress

ure

(MP

a)

0.890.88

0.87

0.86

0.85

0.84

0.83

0.82

0.81

0.800

0.90 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2

Out

let p

ress

ure

(MP

a)

Inlet pressure (MPa) Inlet pressure (MPa)

0.37

0.36

0.35

0.34

0.33

0.32

0.31

0.30

00.90 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2

Out

let p

ress

ure

(MP

a)

0.35

0.30

0.25

0.20

0.15

0.10

0.05

00 50 100 150 200 250 300 350 400 450 500

0.900.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

00 100 200 300 400 500 600 700 800 900 1000

Set pointSet point

Set pointSet point

14-4-63

Regulator for 2 MPa Series ARX20

Construction

Dimensions

JIS Symbol

No.

q

w

Description Material

ADC

POM

NoteBody

Bonnet

No.

e

r

t

y

u

Description Material

POM

POM, NBR

Brass, NBR

Stainless steel

Steel wire

Part no.Handle

Piston assembly

Valve

Valve spring

Adjusting spring

1348102#1

1348104A

1348105

1348109

1348108 (For 0.85 MPa)

1348108-1 (For 0.3 MPa)

Component Parts Replacement Parts

Panel cutout dimensions

SUP OUT

SUP OUT

�35

54

12

25

OUTOUT

AA

ø37

44

5.4

1.6

(Max

. thi

ckne

ss 4

.5)

SMC

P U S H L O CK

ø26

R2.5

1031

.5

79.5

(W

hen

regu

latin

g pr

essu

re =

82)

q

w

e r

u

t

y

Series ARX20

14-4-64

F.R.L.

AV

AU

AF

AR

IR

VEX

AMR

ITV

IC

VBA

VE�

VY1

G

PPA

AL

Option

Panel NutPart no.

Material

1348110APOM, NBR (Gasket)

Dimensions

∗ Install the gasket underneath the panel and bracket (bonnet side). Tighten the panel nut by hand without the use of tools.

BracketPart no.

Material

1348112SPCC (Black zinc chromated)

Dimensions

41.5

17

1.6

5.4

111.

5

Max

. pan

elth

ickn

ess

4.5

mm

1225

ø26

ø34

R16.5

4-R2.5

ø24

54

2444

Panel nut

Gasket

1. Confirm the regulating pressure range. Be sure to install safety devices in locations where output pressure above the regulating pressure range can lead to damage or malfunction of equipment in the outlet pressure side.

2. Residual pressure relief without supply pressure.In cases where the supply pressure is removed with the downstream pressure in a low pressure setting state, it may not be possible to eliminate the downstream pressure (residual pressure relief). Provide a residual pressure relief circuit for cases in which reliable elimination of downstream pressure must be performed.

Design and Selection

Warning1. To set the correct pressure

1)Set the pressure by increasing from a lower pressure to the desired setting, and lock the handle after the pressure is set.

2)Make connections after confirming the “SUP” mark which indicates the air inlet. Reversed connections will cause malfunction.

Mounting

Caution

Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Precautions

14-4-65

Regulator for 2 MPa Series ARX20

14-4-66