msa europe 2005 airelite 4h the unique closed circuit breathing apparatus 4 hours rated service time...

28
MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

Upload: pierce-hood

Post on 18-Dec-2015

221 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

The unique Closed Circuit Breathing Apparatus

4 hours rated service time

Air regeneration with KO2

Innovative Hi-Tech

Page 2: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Design:2 KO2-canisters

with automatic starters

and service free cooling

Exhalation bag

Inhalation bag

Surplus valve

Blower assisted exhalation

Battery

IC-Air control monitor

Charging jack

Page 3: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Design:

Electronic terminal block

Mask connector, automatic start, air hoses Consumption sensor

Air flow routing and convection cooler

Air distributor

Particle filter

Page 4: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Circuit:

Exhalation

Inhalation

The exhalation air is enriched with oxygen

CO2 and H2O are absorbed

Page 5: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

KO2 - function and reaction:

2KO2 + CO2 + H2O >> [K2CO3*H2O] + 1.5 O2 + E(Potassium Hyperoxide) (Potassium Carbonate) (Heat) KO2 is a very reactive, extremely stable chemical, reacting with the humidity and the CO2 of the exhalation air, releasing O2 and heat (exothermic reaction)

KO2 oxidises reliably all foreign substances

... and the breathing air is very dry!

Page 6: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

KO2 - reaction:

2KO2 + CO2 + H2O >> [K2CO3*H2O] + 1.5 O2 + E: Increased exhalation = more CO2 + more H2O raise the oxygen generation! Or vice versa, less consumption reduces the O2-generation. At any time, more O2 is generated than used!

Page 7: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Flexible Service Time:The service time depends on the respiration perform- ance. High performance (heavy work) increases the oxygen generation, low performance (light work) extends the service time!

Sudden changes to high performance are compen-sated by the oxygen surplus!

0

120

240

360

480

600

720

10 20 30 40 50 60Tim

e (

min

ute

s)

Respiration (Litres/minute)

Service Time : Consumption

End of rated service time

0

120

240

360

480

600

720

10 20 30 40 50 6010 20 30 40 50 60

Comparison: SCBA with 2 x 6,8 l/300 bar cylinders = AirElite 4h = SCBA

Tim

e (

min

ute

s)

Respiration (Litres/minute)

Page 8: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

7,200 Litres Breathing Air for 4 hours at 30 litres / minute consumption

DIN 58652 - Respiratory Protective Devices - Self Contained Closed Circuit B. A. - Part 2: Chemical Oxygen (KO2) Generating Type for work and rescue

and

vfdb 0802 (Regulations for the selection and use of Respiratory Protection Devices and Chemical Protection Suits for the Fire Brigades) including appendix D (Flame engulfment)

Page 9: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

The breathing air regeneration

Advantage:

O2-generation / CO2-absorption are effected exclusively by KO2:

in one stage, compressed oxygen and CO2 absorbers (soda lime), that must match each other, are not needed.

Page 10: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

KO2 - B. A. do not need:

oxygen cylinders

oxygen pumps

deep freezers for ice production

Page 11: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

KO2 offers:

optimal O2-surplus there is no compressed-O2-reserve, which may cause a CO2-intoxication if the soda lime cartridge is exhausted prematurely [CO2 -enrichment in the closed circuit]

a CO2 intoxication is impossible!

Page 12: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

KO2 is:

totally breath controlled (no valves and pressure reducers that need maintenance)

simple in construction, has very safe function, and is very quickly ready for use.

almost maintenance free

long storable

Page 13: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

What is happening in the KO2-canisters?

CO2-absorption

water absorption

O2-generation

chemical transformation of KO2

generation of heat air cooled heat exchangers + maintenance free water cooling

Page 14: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Dimensions

and weight:

360 mm

600

mm

190 mm

15 kg

Page 15: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Simple donning anddoffing, also during use (breathing hoses under left arm)

Page 16: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Low cost training

TR-conversion kit for quick conversion of the operational AirElite into a trainer

Page 17: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

dependent of the ambient air,

the P3 particle filter permits training in dense fog and nontoxic smoke

Trainer

Page 18: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

and the IC-Air

manages and monitors the AirElite

clears the AirElite for the mission

warns of defects

counts the consumption

signals audibly and visually

alarms at immobility

offers a manual alarm

Page 19: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

and the IC-Air

Test button and display illumination

LED red/greenManual immobility alarm

Reset and calibration

Automatic immobility alarm > 95 dBa

Page 20: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

IC-Air display at start :

Function check: display segments + + beep + light = OK

Failures: 1 = battery

2 = starter / canister

3 = blower

8 = sensor Beep

1

Page 21: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

IC-Air display in use:

Capacity indication: 100 % to 0 %

Cylinder symbol : 8 segments

50 % residual capacity: short beep 15 sec

20 % residual capacity: LED red/green, interval beep, escape symbol

5 % residual capacity: LED flashing red, continuous beep, escape symbol flashing

0 % residual capacity: AirElite continues operation

Page 22: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Donning:

Page 23: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Inspection & Maintenance6 months: visual check (lead seals)

recharge battery

check readiness (test button)

(if fitted) 2 years: replace KO2-canisters training

5 years: replace battery consume originally packed KO2-canisters

Page 24: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Cleaning & Disinfection Mask Breathing tubes Breathing bag and valve control Air distributor Blower (spray disinfection only)

Page 25: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Page 26: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Application

Mining: Mine Rescue Teams

The BA on site with the lowest maintenance requirements, the least periphery logistics,the fastest readiness, the most cost efficient training.

The BA for quick missions!

Page 27: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

Application

Fire Brigade:

The BA for the rare long-run missions!For stand-by rescue teams(2 AirElite for fire engines)Fire Brigades with tunnel missions(Railways/Subways/Road tunnels)Chemical industries, Refineries, Tank farms.Military facilities, Bunkers, Depots.Port authorities: onboard fire fighting

Free from frequent service & maintenance!

Page 28: MSA EUROPE 2005 AirElite 4h The unique Closed Circuit Breathing Apparatus 4 hours rated service time Air regeneration with KO 2 Innovative Hi-Tech

MSA EUROPE 2005

AirElite 4h

USPs in a nutshell: excellent breathing comfort: low resistances

low air temperature

dry breathing air maintenance and ice free cooling

no periphery logistics (cylinders, pumps, ice) low cost training

slim design, breathing hoses under the arm