© mv apparatus & switchgear - 1 -2007/01 pole mounted switch disconnector nps 630 a, up to 36...

32
© MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

Upload: corey-stewart

Post on 27-Dec-2015

261 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r-

1 -2

007/

01

Pole MountedSwitch DisconnectorNPS

630 A, up to 36 kV

Page 2: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

2 -

NPS Pole Mounted Switch Disconnectors

Easy and smart integrations

Adaptable to all customer/country building standards

Modular concept

Suitable for live working

Flexible concept

From the simplest of manually operated units to motorized and automated remotely controlled units

Wide range of accessories

Upgrading in switching performance

Page 3: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

3 -

NPS Pole Mounted Switch Disconnectors

Enhanced performance and improved reliability

Only insulators with the best materials are used Cycloaliphatic epoxy with over 30 years of field experience

in more than 50 countries

High quality silicone or porcelain insulators are also available

Lightweight design with a limited number of parts guarantees a long lifetime and trouble-free operation

Page 4: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

4 -

NPS as a Line Switch Disconnector

Page 5: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

5 -

Crossarm installation

One of the most common building standards where the line switch disconnector is integrated on the same crossarm as the lines.

Wooden poles are most often used for this type of installation.

Page 6: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

6 -

Installation below live line

Some building styles and standards require a separate crossarm below the line crossarm.

Sufficient clearances to the pole and between phases can be arranged by the flexible arrangement of phase elements.

Page 7: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

7 -

Installation above live line

A typical installation example above the live line on a steel structure pole.

Page 8: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

8 -

Vertical installation

Used for branching lines down to cables.

The vertically installed switch disconnector is also used as a transformer switch disconnector.

Page 9: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

9 -

Two pole mounting

All installation examples are also available for two-pole mounting.

Pole fitting accessories for various pole types are also available wooden poles concrete poles steel poles and structures

Page 10: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

10

-NPS for Transformer Switch Disconnector/NPF fuse holder

Page 11: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

11

-

Fuse holders

The NPS switch disconnector can be equipped with several types of fuse holders.

The vertically mounted NPS can be used as transformer switch disconnector.

The breaking capacity of the whip (25/50 A) is enough for disconnecting a fully loaded distribution transformer up to 800/1600 kVA.

NPS24B1-J2 and NPAC5

Page 12: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

12

-

Fuse holders

If the pole element is horizontally mounted the fuse holder for HRC fuses (6.3, 16, 25 A) or (SMIA-KR_) melting fuses can be easily integrated (up to 63 A) to the switch disconnector.

The fuses are replaced using isolated rods from ground level.

NPS24B1-J2,NPAC9-J2 andNPAF7-J2

Page 13: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

13

-

Fuse holders

NPS can be equipped with integrated earthing contact for open and earthed position.

The separate fuse holder for HRC and SMIA-KR_ can also be equipped with surge arresters for one-, two-, or three-phase installation.

NPS24B1-J2NPAE5

NPF24B2

Page 14: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

14

-

Fuse holders

NPS can be equipped with a separate fuse holder for DIN-type fuses (CEF outdoor HRC fuses).

NPF24E5

ANSI

25.5 kV 160 A25.8 kV 100 A38.0 kV 40 A

IEC 282

7.2 kV up to 160 A12.0 kV up to 100 A17.5 kV up to 100 A24.0 kV up to 100 A36.0 kV up to 40 A

Page 15: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

15

-

Components for substation switch disconnectors

Page 16: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

16

-

Accessories

Page 17: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

17

-

Feeder Automation

Page 18: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

18

-

Terminal with REC 523

One terminal with REC 523 can control up to 4 slave units.

Page 19: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

19

-DTU Operating Device for pole mountedswitch disconnector type NPS or other types

Page 20: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

20

-

DTU Operating Device

The product range includes master and slave units

Can be equipped with third party electronics/IED

Two different cabinet sizes

Complete with batteries and chargers

Up/down tube operation of disconnectors

Stainless steel cabinet and mechanism

Dust tight (IP55) to secure long lifetime of critical electrical components

High torque, alternative 1.2 sec or 3 sec operating time

Best possible materials used

Over 30 years experience

Operating voltages: 24, 48, 110, 220 VDC 110, 230 VAC

Page 21: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

21

-

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA

NPS Basic pole element

Disconnector (IEC)

No breaking capacity

For disconnecting functions only

Provides a safe isolating distance

NPS24B1-WWJ2

Page 22: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

22

-

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA

NPS with 25 A breaking whip Limited purpose switch disconnector (IEC) Breaking 25 A/24 kV 40 A/12 kV For disconnecting

functions only Provides a safe isolating distance

NPS24B1-J2NPS24B1-J3

Page 23: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

23

-

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA

NPS with 50 A breaking whip

Limited purpose switchdisconnector (IEC)

Breaking

50 A/24 kV80 A/12 kV

With extended breaking capacity in rural areas and transformer loads.

NPS24B1-K1J2

Page 24: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

24

-

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA

NPS with 250 A breaking chamber

Limited purpose switchdisconnector (IEC)

Breaking

250 A/24 kV

For main lines and subtationswhere larger breaking capacity is needed.

NPS24B1-K4J2

Page 25: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

25

-

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA

NPS with K5 air making and breaking chamber General purpose switch

disconnector (IEC) Maximum breaking and

independent spring assisted making capacity

630 A/24 kV 8 kA/24 kV

12.5 kA/12 kV For main lines and substations

where both breaking and making capacity is needed.

Excellent for remote and autosectionalizers.

NPS24B1-K5J2 NPS24B1-K5J3

NPAC9-J3

Page 26: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

26

-

Breaking devices on NPS24A for max. Ith/Idyn 20/50 kA

For overhead networks with BIL up to 150 kV. Silicone insulator J3.

NPS24A2-J3 NPS24A2-K5J3 NPS24A2-K5J3NPAC1-J3

Page 27: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

27

-

Breaking devices on NPS36A for max. Ith/Idyn 21/52 kA

For overhead networks with BIL, up to 200 kV. Whip (16 A) or breaking chamber K3 (400 A) can be used ase breaking elements.

Two alternative silicone insulators (J2 or J3).

NPS36A2-J2 NPS36A2-K3J2 NPS36A2-K3J2NPAC11-J2

Page 28: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

28

-

Unique design

The unique design on breaking whips and dry type breaking chambers eliminates the risk of oil leakage.

Risk of oil eliminated Pollution risk for soil waters

Safety risk in case of failed interruption

No need to check oil level or compensate for possible leakages

Risk of conventional air breaking chambers eliminated by protected breaking contacts Malfunctions due to dust, sand, ice and

small animals

Risk of terrain fires due to arcing

Page 29: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

29

-

Manual operating mechanism

UEKE 5A1

Hook stick lever

Hook stick operation mechanism for NPS24B_ models.

Also available for mounting on lower level.

UEKO 1A1

One hand grip operating mechanism for low end disconnectors

Page 30: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

30

-

Manual operating mechanism

UEKE 3A1

Standard two hand grip operating mechanism for all NPS_ models.

UEKE 3B1

Standard two hand grip operating mechanism for all NPS_ models with additional quick adjustment rod.

Page 31: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

© M

V A

ppar

atus

& S

witc

hgea

r -

31

-

Manual operating mechanism

UEKE 2/1

With auxiliary contacts and heating element IP55.

UEKE 6A1

Wire operation

Page 32: © MV Apparatus & Switchgear - 1 -2007/01 Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV