sect-swale...title: sect-swale created date: 1/8/2018 4:09:55 pm

11
11.88" 11.88" 18" 20" 18" 20" 18.63" 11.88" 20" 8" 8" 8" 4" 11.94" 10.38" 17.25" 18" 9" 18" 8" Title: The suitability and/or manner of use of any details contained in this document is the sole responsibility of the user. Final project specific designs shall be prepared by a licensed professional engineer. Copyright 2017 Keystone Retaining Wall Systems, LLC Project: Valera Pro Details 8" Single Unit Details Revision: Date: Drawing No: Designed By: Checked By: No Scale Scale: Tri-Plane Face Unit Straight Face Unit Deco Face Unit Cap Unit Corner Unit Dimensions May Vary by Region * 1 of CDM RKM 11 12-19-17 4444 W 78th St, Minneapolis, MN 55435 952-897-1040

Upload: others

Post on 31-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • 11.88"

    11.88"

    18"

    20"

    18"

    20"

    18.63"

    11.88" 20"

    8" 8"8"

    4"11.

    94" 10.38"

    17.25"

    18"9"

    18"

    8"

    Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details 8" Single Unit Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Tri-Plane Face Unit Straight Face UnitDeco Face Unit

    Cap Unit Corner Unit

    Dimensions May Vary by Region*

    1 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • 17.25"

    11.94" 10.

    38"

    4"

    Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Cap Unit Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Cap Units Inside Curve Cap Units Corner / Wall

    Cap Units Wall Step PlanCap Units Wall Step

    Isometric

    Cap Unit

    Cap Units Outside Curve

    Split Cap End

    Split Cap Both Ends

    Split Cap End

    Cut Cap Unit as Required at End of Wall

    Cut Cap Units as Requiredto Construct a Mitered 90 Degree Corner

    Cut Cap Units to Fitas Required

    Cut Cap Units to Fitas Required

    2 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Gravity Wall Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Gravity Wall Typical Section

    Cap Unit

    Valera Pro Unit

    FinishedGrade

    Total WallHeight

    Embedment

    32"

    6"

    24" (Min.) of FreeDraining Aggregate

    4" Ø (Min) Drain Tile(Elevation Varies)(See Note)

    4" Ø (Min) Drain Tile(Elevation Varies) - or -

    6" (Min) CompactedGranular Base Leveling Pad

    Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.

    Low Permeable Soil

    9/16"

    8"

    3 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Reinforced Wall Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Cap Unit

    Valera Pro Unit

    FinishedGrade

    Total WallHeight

    Embedment

    32"

    6"

    4" Ø (Min) Drain Tile(Elevation Varies)

    4" Ø (Min) Drain Tile(Elevation Varies) - or -

    6" (Min) CompactedGranular Base Leveling Pad

    24" (Min.) of FreeDraining Aggregate

    GeosyntheticReinforcement(Typ)

    Reinforced Soil

    Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.

    Typical Reinforced Wall Section

    Low Permeable Soil

    9/16"

    8"

    4 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Tiered Wall Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Valera Pro Unit

    Finished Grade

    32"

    6" 6" (Min) CompactedGranular BaseLeveling Pad

    24" (Min.) of FreeDraining AggregateGeosynthetic

    Reinforcement(Typ)

    Reinforced Soil

    Varies

    Cap Unit

    Total TierHeight

    Embedment

    Embedment

    Typical Tiered Section

    Rear Drain SytemWhen Required

    9/16"

    8"

    9/16"

    8"

    5 ofCDMRKM 11

    Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.

    4" Ø (Min) Drain Tile(Elevation Varies)

    4" Ø (Min) Drain Tile(Elevation Varies) - or -

    12-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Inside Corner Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Typical Base and / or OddNumbered Courses Plan

    Inside Corner Isometric

    Typical 2nd and / or EvenNumbered Courses Plan

    Inside Corner Plan with Geogrid

    Block Note:Cut units as required to maintain running bond pattern.

    Grid

    Str

    engt

    h Di

    rect

    ion

    Grid Strength Direction

    Free DrainingAggregate

    Cut Unit

    Additional Geogrid OverlapExtension (See Note)

    H/4

    H/4

    Geogrid Note:Measure, cut and orient the geogrid, as per the engineers design andthe geogrid manufacturers specifications on correct strength direction.

    Extend geogrid the wall height / 4 (H / 4) beyond the adjoining wallface at inside wall corners.

    The reinforcement should not extend into the retaining wall units onthe perpendicular leg of the 90 degree corner.

    Geogrid Reinforcement(Typ.)

    3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.).

    6 ofCDMRKM 11

    Free DrainingAggregate

    Cut Unit

    12-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Outside Corner Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Typical Base and / or OddNumbered Courses Plan

    Outside Corner Isometric

    Typical 2nd and / or EvenNumbered Courses Plan

    Outside Corner Plan with Geogrid

    Block Note:Cut units as required to maintain runningbond pattern.

    Free DrainingAggregate

    Corner Unit

    Geogrid Reinforcement(Typ.)

    3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.).

    Corner Unit

    H/2

    H/2

    H/2

    H/2

    Wall Corner AdditionalFree DrainingAggregate Fill Limits(See Notes)

    Free DrainingAggregate

    Wall Corner AdditionalFree DrainingAggregate Fill Limits(See Notes)

    Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.

    The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.

    Free Draining Aggregate Note:Place additional free draining aggregatefill at outside wall corners to extend backfrom wall face each way a distance equalto the wall height / 2 (H / 2).

    7 ofCDMRKM 11

    Grid Strength Direction

    Grid

    Str

    engt

    h Di

    rect

    ion

    12-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Inside Curve Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Typical Inside Curve Plan

    Inside Curve IsometricInside Curve Plan with Geogrid

    Block Note:Cut units as required to maintain running bond pattern.

    Free DrainingAggregate

    Valera Pro Unit

    Place Additional Pieces of GeogridWhen Gap Angle Exceeds 20° onInside Wall Curves

    Geogrid Reinforcement(Typ)

    8 ofCDMRKM 11

    Grid

    Str

    engt

    h Di

    rect

    ion

    Grid Strength Direction

    Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.

    The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.

    12-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Outside Curve Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Typical Outside Curve Plan

    Outside Curve Isometric

    Outside Curve Plan with Geogrid

    Block Note:Cut units as required to maintain running bond pattern.

    Free DrainingAggregate

    Valera Pro Unit

    3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.)

    H/2

    H/2

    Geogrid Reinforcement (Typ)

    Additional Corner Free DrainingAggregate (See Notes)

    9 ofCDMRKM 11

    Grid Strength Direction

    Grid

    Str

    engt

    h Di

    rect

    ion

    Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.

    The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.

    Free Draining Aggregate Note:Place additional free draining aggregatefill at outside wall corners to extend backfrom wall face each way a distance equalto the wall height / 2 (H / 2).

    12-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Top of Wall Fence Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Cap Unit

    Valera Pro Unit

    Finished Grade

    25" ±

    Minimum Offset Fence Section

    Note:Concrete filled tube or form to be set during the wallconstruction, not drilled through geogrid afterwardswhen directly behind units.

    Steel Fence or Railing

    36" M

    in.

    Geosynthetic Reinforcement(Typ)

    Concrete Filled Tube orForm 8' o.c. Max.

    Cap Unit

    Valera Pro Unit

    FinishedGrade

    36"

    Steel Fence or Railing

    24" M

    in.

    Geosynthetic Reinforcement(Typ)

    Concrete Filled Tube orForm 8' o.c. Max.

    Fence Section

    10 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

  • Title:

    The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.

    Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Valera Pro Details Top of Wall Swale Details

    Revision: Date: Drawing No:Designed By: Checked By:

    No Scale

    Scale:

    Cap Unit

    Valera Pro Unit

    Concrete or GrassDrainage Swale toIntercept and DivertSurface Water

    Steel Fence or Railingas Required

    Geosynthetic Reinforcement(Typ)

    Concrete Filled Tube orForm 8' o.c. Max.

    Drainage Swale Section

    24" M

    in.

    Low Permeable soil

    PlasticMembrane

    Expansion Materialw/Concrete

    FinishedGrade

    36" Min.

    8" Min.

    11 ofCDMRKM 1112-19-174444 W 78th St, Minneapolis, MN 55435952-897-1040

    Sheets and ViewsValera Pro Unit Details-UnitsPlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Cap UnitsPlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Sect-GrvPlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Sect-GridPlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Sect-TieredPlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Crnr-InsidePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Crnr-OutsidePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Crv-InsidePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Crv-OutsidePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Sect-FencePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3

    Valera Pro Unit Details-Sect-SwalePlotOLE1PS-Iso-Txt-Frt-PlanPS-Iso-Txt-Side-ElevPS-Iso-Txt-Frt-ElevOLE3