· tv-cables (04 - 09) the standard tv cables contain a range of custom designed multi conductor...

36

Upload: hoangxuyen

Post on 12-Apr-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet the highest demands of the

stock while other cables are manufactured to order. Quality is maintained to the highest standard in the industry. MacArtney also supplies engineering services and components to integrate total cable solution packages.

MacArtney Underwater Cables - In stock

For further information please visit: www.macartney.com

TV-Cables (04 - 09) The standard TV cables contain a range of custom designed multi conductor cables for use with underwater TV systems and other equipment. These cables contain a variety of coaxes, twisted pairs and power conductors to allow cameras, lights and pan & tilt units to be powered, controlled and video images carried to the surface. The cables all have Polyurethane outer jackets, allowing them to be easily moulded to connectors to make underwater cable harness assemblies.

Index

Combined Power/Signal Cables (10 - 15) Cables in this section contain a mixture of power conductors and shielded twisted pairs cabled together within a Polyurethane outer jacket. From the simple, two power conductors and one shielded pair, to the more complex cables, there is bound to be a cable that will meet your needs. These cables are ideal for the construction of harness assemblies for transmission of data from point to point.

Instrumentation Cables (16 - 25)The instrumentation cables contain a number of cables for a variety of purposes. From one shielded twisted pair to several shielded twisted pairs or single conductors with overall shield. Cables in this section have Polyurethane outer jacket, allowing them to be easily moulded to connectors to make underwater cable harness assemblies.

Fibre Optic Cables (26 - 30)

in these cables has undergone many years of development and has a long track record of successful operation down to 6000 meters water depth. The individual elements are combined and packaged within a Polyurethane outer jacket providing additional protection

range.

Special Cables (31 - 32)Our program for these cables covers most of the market demands. These include long steel armoured tow cables for sophisticated military arrays to short lengths of instrument cables for CTD probes. Fibre optic cables are playing an increasingly important role in this section of the market and our in-house engineering can support our customers with cable and termination designs and advise on tow characteristics etc.

Terminations (34 - 35)Our standard shackle or fork terminations are safe and reliable methods of connecting cable to towed underwater vehicles or for lifting a heavy object, such as a down-hole camera system. Terminating and moulding the cable to a connector ensures a watertight connection from cable to system. MacArtney stocks standard terminations for steel armoured or Kevlar armoured cables with diameters of 6 to 14mm and loads of up to 1500kg. We also have extensive experience of designing terminations for loads of up to 100 tonnes.

Non Stock Cables (33)Sonar & Acoustic System CablesVideo System UmbilicalsROV and Trencher UmbilicalsDynamic Cable Ancilliary Products

TV cables

Micro TV cable - Type 6075

Coax 75 ohm coax (1 ea.) Conductors 1,00 mm2 bare copper conductor insulated with PE (2 ea.) Shield Aluminium/polyester foil and tinned copper drain wire, coverage 100% Outer jacket Polyurethane jacket. Colour orange

Diameter 7,50 mm ±0,25 mm Weight in air 73 kg/ km nom. Weight in seawater 28 kg/ km nom. Min. bending radius, static 50 mm Min. bending radius, dynamic 60 mm Depth rating 5000 m

Operating voltage 600 V for conductors Test voltage 1500 V DC for 1 min. Conductor resistance 250,0 ohm/ km for coax 20,0 ohm/ km for conductors Insulation resistance 5000 Mohm* km Capacitance 59 pF/ m for coax Attenuation 4,30 dB/ 100 m at 5 MHz for coax 6.50 dB/ 100 m at 10 MHz for coax 13.80 dB/ 100 m at 50 MHz for coax 18.60 dB/ 100 m at 100 MHz for coax 67.11 dB/ 100 m at 1000 MHz for coax

No. 2004727C - Rev C - 02/12 04

TV cables

Mini TV Cable - Type 6011

Coax 75 ohm coax (1 ea.) Conductor 1,34 mm2 bare copper conductor insulated with PE (1 ea.) Shielded twisted pair 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)

Shielded twisted pair 1,34 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 ea.) Twisted pair 0,22 mm2 tinned copper conductor insulated with PE. Two conductors twisted together (1 ea.) Filling compound The cable is filled with cable filling compound

Shield Aluminium/polyester foil and tinned copper drain wire, coverage 100% Outer jacket Polyurethane jacket. Colour orange

Diameter 11,00 mm ±0,50 mm Weight in air 165 kg/km nom. Weight in seawater 70 kg/km nom. Min. bending radius, static 100 mm Min. bending radius, dynamic 145 mm Depth rating 5000m

Operating voltage 600 V for 1,34 mm2 and 0,50 mm2 conductors

24 V for 0,22 mm2 conductors Conductor resistance 135,0 ohm/km for coax 15,3 ohm/km for 1,34 mm2 conductors 41,0 ohm/km for 0,50 mm2 conductors 96,2 ohm/km for 0,22 mm2 conductors Insulation resistance 5000 Mohm*km for coax, 1,34 mm2 and 0,22 mm2 conductor 10000 Mohm*km for 1,34 mm2 and 0,50 mm2 conductors (cond./cond.) 100 Mohm*100 m for 1,34 mm2 and 0,50 mm2 conductors (cond./shield) Capacitance 59 pF/m for coax 155 pF/m for 1,34 mm2 pair 107 pF/m for 0,50 mm2 pair 57 pF/km for 0,22 mm2 pair Impedance 37 ± 5 Ohm at 1-10 MHz for 1.34 mm² pair 52 ± 5 Ohm at 1-10 MHz for 0.50 mm² pair 73 ± 5 Ohm at 1-10 MHz for 0.22 mm² pair

Attenuation 7.0 dB/100m at 1 MHz for 1.34 mm², 0.50 mm² and 0.22 mm² pair 17.5 dB/100m at 10 MHz for 1.34 mm² pair 18.0 dB/100m at 10 MHz for 0.50 mm² and 0.22 mm² pair

No. 2000543C - Rev G - 02/12 05

TV cables

Kelvar TV cable - Type 6926

Coax 75 ohm coax (1 ea.) Conductors 1,00 mm2 bare copper conductor insulated with PE (8 ea.)

Shielded twisted quint 0,14 mm2 tinned copper conductors insulated with PE. Five conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 ea.) Shielded twisted quad 0,22 mm2 tinned copper conductors insulated with PE. Four conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 ea.) Filling compound The cable is filled with cable filling compound Strength member Kevlar braid. Outer jacket Polyurethane jacket. Colour red

Diameter 14,40 mm ±0,50 mm Weight in air 275 kg/ km nom. Weight in seawater 108 kg/ km nom. Min. bending radius, static 100 mm Min. bending radius, dynamic 200 mm Min. breaking strength 7 kN Depth rating 5000 m

Operating voltage 600 V for 1,00 mm2 conductors 24 V for 0,22 mm2 and 0,14 mm2 conductors Test voltage 1500 V DC for 1 min. for coax, 0,22 mm2 and 0,14 mm2 conductor 3000 V DC for 1 min. for 1,00 mm2 conductor Conductor resistance 89,5 ohm/ km for coax 20,0 ohm/ km for 1,00 mm2 conductor 96,2 ohm/ km for 0,22 mm2 conductor 145,0 ohm/ km for 0,14 mm2 conductor Insulation resistance 5000 Mohm* km Capacitance 67 pF/ m for coax 80 pF/ m for 0,22 mm2 quad 65 pF/ m for 0,14 mm2 quint Impedance 75 ± 3 Ohm at 1 MHz for coax Attenuation 2.5 dB/100m at 5 MHz for coax 12.20 dB/100m at 100 MHz for coax 41.50 dB/100m at 1000 MHz for coax

No. 2002621C - Rev. G - 02/12

06

TV cables

TV Cable with 2 coaxes - Type 6120/B

Coax 75 ohm coax (2 ea.)

Twisted quad 0,50 mm2 bare copper conductors insulated with PE. Four conductors twisted together (1 ea.) Shielded twisted pairs 1,34 mm2 bare copper conductors insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (4 ea.) Filling compound The cable is filled with cable filling compound

Outer jacket Polyurethane jacket. Colour orange

Diameter 14,80 mm ±0,20 mm Weight in air 340 kg/km nom. Weight in seawater 165 kg/km nom. Min. bending radius, static 170 mm Min. bending radius, dynamic 225 mm Depth rating 5000 m

Operating voltage 600 V Test voltage 1500 V DC for 1 min. for coax 3000 V DC for 1 min. for 0,50 mm2 and 1,34 mm2 conductors

Conductor resistance 89,5 ohm/ km for coax 41,0 ohm/ km for 0,50 mm2 conductor 15,3 ohm/ km for 1,34 mm2 conductor Insulation resistance 5000 Mohm* km Capacitance 56 pF/ m for coax 50 pF/ m for 0,50 mm2 quad 190 pF/ m for 1,34 mm2 pair Impedance 37 ± 5 Ohm at 1-10 MHz for 1,34 mm² pair Attenuation 3.00 dB/ 100 m at 5 MHz for coax 4.30 dB/ 100 m at 10 MHz for coax 44.3 dB/ 100 m at 1000 MHz for coax 7.0 dB/ 100 m at 1 MHz for twisted pair 17.5 dB/ 100 m at 10 MHz for twisted pair

No. 2000575 1C - Rev. C. - 02/12 07

TV cables

TV cable with 3 coaxes - Type 6130

Coax 75 ohm coax (3 ea.) Shielded twisted pairs 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire, aluminium/polyester foil and a PE sheath (3 ea.)

Conductor 1,00 mm2 bare copper conductor insulated with PE (2 ea.)

Filling compound The cable is filled with cable filling compound

Outer jacket Polyurethane jacket. Colour blue

Diameter 14,00 mm ±0,50 mm Weight in air 260 kg/ km nom. Weight in seawater 98 kg/ km nom. Min. bending radius, static 90 mm Min. bending radius, dynamic 135 mm Depth rating 5000 m

Operating voltage 600 V Test voltage 1500 V DC for 1 min. for coax 3000 V DC for 1 min. for 1,00 mm2 and 0,50 mm2 conductors Conductor resistance 135,0 ohm/ km for coax 20,0 ohm/ km for 1,00 mm2 conductors 41,0 ohm/ km for 0,50 mm2 conductors Insulation resistance 5000 Mohm* km for coax and 1,00 mm2 conductors 10000 Mohm* km for 0,50 mm2 conductors (cond./cond.) 100 Mohm*100 m for 0,50 mm2 conductors (cond./shield) Capacitance 59 pF/ m for coax 107 pF/ m for 0,50 mm2 pair Impedance 52 ± 5 Ohm at 1-10 MHz for 0.50 mm² pair Attenuation 3,79 dB/ 100 m at 5 MHz for coax 5.32 dB/ 100 m at 10 MHz for coax 17.44 dB/ 100 m at 100 MHz for coax 67.11 dB/ 100 m at 1000 MHz for coax 7.0 dB/ 100 m at 1 MHz for 0,55 mm² pair 18.0 dB/ 100 at 10 MHz for 0.55 mm² pair

No. 2002623C - Rev. F - 02/12 08

TV cables

Special TV cable - Type 6013/B

Coax 75 ohm coax (1 ea.)

Conductors 2,00 mm2 bare copper conductor insulated with PE (2 ea.) Shielded twisted pair 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil. (1 ea.) Shielded twisted quad 0,22 mm2 bare copper conductor insulated with PE. Four conductors twisted together with a tinned copper drain wire and aluminium/polyester foil. (1 ea.) Twisted pairs 1,34 mm2 bare copper conductor insulated with PE. Two conductors twisted together. (2 ea.) Filling compound The cable is filled with cable filling compound Shield Aluminium/polyester foil and tinned copper drain wire, coverage 100% Outer jacket Polyurethane jacket. Colour yellow

Diameter 14,50 mm ±0,40 mm Weight in air 255 kg/ km nom. Weight in seawater 86 kg/ km nom. Min. bending radius, static 150 mm Min. bending radius, dynamic 215 mm Depth rating 5000 m

Operating voltage 600 V for 0,50 mm2, 2,00 mm2 and 1,34 mm2 conductors 24 V for 0,22 mm2 conductors

Conductor resistance 135 ohm/ km for coax 10,0 ohm/ km for 2,00 mm2 conductors 41,0 ohm/ km for 0,50 mm2 conductors 96,2 ohm/ km for 0,22 mm2 conductors 15,3 ohm/ km for 1,34 mm2 conductors Insulation resistance 5000 Mohm* km for coax, 2,00 mm2 conductors and 1,34 mm2 conductors 10000 Mohm* km for 0,50 mm2 conductors and 0,22 mm2 conductors Capacitance 59 pF/ m for coax 80 pF/ m for 0,50 mm2 and 1,34 mm2 pair 65 pF/ m for 0,22 mm2 quad Attenuation 3.79 dB/ 100 m at 5 MHz for coax 5.32 dB/ 100 m at 10 MHz for coax 67.11 dB/ 100 m at 1000 MHz for coax

No. 2005741C - Rev. C - 02/12 09

Combined power / signal cables

Seismic cable - Type 2009/B

Power conductors 2,00 mm2 bare copper conductor insulated with PVC (2 ea.) Shielded twisted pair 0,22 mm2 bare copper conductor insulated with PE. Two conductors twisted Together with a tinned copper drain wire and aluminium/ polyester foil. (2 ea.) Inner jacket PVC jacket Outer jacket Polyurethane jacket. Colour blue

Diameter 9,00 mm ±0,30 mm Weight in air 125 kg/ km nom. Weight in seawater 60 kg/ km nom. Min. bending radius, static 100 mm Min. bending radius, dynamic 130 mm Depth rating 3000 m

Operating voltage 600 V for 2,00 mm2 conductors 24 V for 0,22 mm2 conductors Test voltage 3000 V DC for 1 min. for 2,00 mm2 conductors (cond./cond.) 1500 V DC for 1 min. for 0,22 mm2 conductors (cond./cond.)

Conductor resistance 10,0 ohm/ km for 2,00 mm2 conductors 96,2 ohm/ km for 0,22 mm2 conductors Insulation resistance 100 Mohm* km for 2,00 mm2 conductors 5000 Mohm* km for 0,22 mm2 conductors Capacitance 70 pF/ m for 0,22 mm2 pair Characteristic impedance 58 ± 5 Ohm at 1-10 MHz Attenuation at 1 MHz 10.0 dB/ 100 m Attenuation at 10 MHz 25.0 dB/ 100 m

No. 2005742C - Rev. C - 02/12

10

Combined power / signal cables

Seismic cable with kelvar - Type 2019/B

Power conductors 2,00 mm2 bare copper conductor insulated with PVC (2 off) Shielded twisted pair 0,22 mm2 bare copper conductor insulated with PE. Two conductors twisted Together with a tinned copper drain wire and aluminium/ polyester foil. (2 off) Inner jacket PVC jacket Inner jacket Polyurethane jacket Strength member Braided Kevlar Outer jacket Polyurethane jacket. Colour blue

Operating temperature range -20 C to 80 C

Diameter 14,30 mm ±0,30 mm Weight in air 220 kg/ km nom. Weight in seawater 55 kg/ km nom. Min. breaking strength 1500 kg Min. bending radius, static 160 mm Min. bending radius, dynamic 210 mm Depth rating 5000 m

Operating voltage 600 V for 2,00 mm2 conductors 24 V for 0,22 mm2 conductors Test voltage 3000 V DC for 1 min. for 2,00 mm2 conductors (cond./cond.) 1500 V DC for 1 min. for 0,22 mm2 conductors (cond./cond.)

Conductor resistance 10,0 ohm/ km for 2,00 mm2 conductors 96,2 ohm/ km for 0,22 mm2 conductors Insulation resistance 100 Mohm* km for 2,00 mm2 conductors 5000 Mohm* km for 0,22 mm2 conductors

Capacitance 70 pF/m for 0,22 mm2 pair Characteristic impedance 60 ± 5 Ohm for 0,22 mm² pair Attenuation 10,0 dB/ 100 m at 1 MHz 25,0 dB/ 100 m at 10 MHz No. 2005743C -Rev. D - 02/12

11

Combined power / signal cables

Combined power / signal cable - Type 4591

Shielded twisted triad 1,50 mm2 bare copper conductor insulated with PE. Three conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)

Shielded twisted pairs 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (8 ea.) Filling compound The cable is filled with cable filling compound Outer jacket Polyurethane jacket. Colour black

Diameter 19,00 mm ±0,50 mm Weight in air 460 kg/km nom. Weight in seawater 170 kg/km nom. Min. bending radius, static 125 mm Min. bending radius, dynamic 185 mm Depth rating 5000 m

Operating voltage 1000 V DC for 1,50 mm2 conductors 600 V DC for 0,50 mm2 conductors Test voltage 4000 V DC for 1 min. for 1,50 mm2 conductor 3000 V DC for 1 min. for 0,50 mm2 conductor

Conductor resistance 13,7 ohm/ km for 1,50 mm2 conductor 41,0 ohm/ km for 0,50 mm2 conductor Insulation resistance 10000 Mohm* km (cond./shield) 100 Mohm* 100 m (shield/shield) Capacitance 80 pF/m for 1,50 mm2 triad 100 pF/m for 0,50 mm2 pair Impedance 57 ± 5 Ohm for 0,5 mm² pair Attenuation 7.0 dB/ 100 m at 1 MHz 18.0 dB/ 100 m at 10 MHz

No. 2002626C - Rev. F - 02/12 12

Combined power / signal cables

Combined power / signal cable - Type 4622

Power conductors 1,00 mm2 bare copper conductor insulated with PE. (2 ea.)

Shielded twisted pairs 0,22 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire, aluminium/polyester foil and a PE sheath (1 ea.)

Shielded twisted pairs 0,22 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and a aluminium/polyester foil (5 ea.) Shield Tinned copper braid, coverage 85% Outer jacket Polyurethane jacket. Colour blue

Diameter 12,00 mm ±0,40 mm Weight in air 200 kg/km nom. Weight in seawater 110 kg/km nom. Min. bending radius, static 80 mm Min. bending radius, dynamic 120 mm Depth rating 3000 m

Operating voltage 600 V DC for 1,00 mm2 conductors 24 V DC for 0,22 mm2 conductors Test voltage 3000 V DC for 1 min. for 1,00 mm2 conductor 1500 V DC for 1 min. for 0,22 mm2 conductor

Conductor resistance 20,0 ohm/km for 1,00 mm2 conductor 96,2 ohm/km for 0,22 mm2 conductor Insulation resistance > 100 Mohm* km (cond./cond.) > 50 Mohm* km (cond./shield) > 10 Mohm* km (shield/shield) Capacitance 85 pF/ m for 0,22 mm2 pair Impedance 60 ± 5 Ohm at 1-10 MHz for 0,22 mm² pair Attenuation 10.0 dB/ 100 m at 1 MHz 25.0 dB/ 100 m at 10 MHz No. 2005745C - Rev. C - 02/12

13

Combined power / signal cables

Combined power / signal cable - Type 4971

Power conductors 2,50 mm2 bare copper conductor insulated with PE. (2 off)

Shielded twisted pair 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 off) Outer jacket Polyurethane jacket. Colour orange

Operating temperature range -20 C to 80 C

Diameter 11,00 mm ±0,30 mm Weight in air 160 kg/ km nom. Weight in seawater 65 kg/ km nom. Min. bending radius, static 130 mm Min. bending radius, dynamic 165 mm Depth rating 3000 m

Operating voltage 600 V DC for 2,50 mm2 conductors 300 V DC for 0,50 mm2 conductors Test voltage 4000 V DC for 1 min. for 2,50 mm2 conductors 3000 V DC for 1 min. for 0,50 mm2 conductors

Conductor resistance 8,0 ohm/ km for 2,50 mm2 conductors 41,0 ohm/ km for 0,50 mm2 conductors Insulation resistance 5000 Mohm* km for 2,50 mm2 conductors 10000 Mohm* km for 0,50 mm2 conductors (cond./cond.) 100 Mohm* 100 m for 0,50 mm2 conductors (cond./shield) Capacitance 100 pF/m for 0,50 mm2 pair at 800 – 1200 Hz nom. Characteristic impedance (1-10 MHz) 57 ± 5 Ohm for 0,50 mm² conductors Attenuation 7.0 dB/ 100 m at 1 MHz 18.0 dB/ 100 m at 10 MHz

No. 2005747C - Rev. B - 02/12 14

Combined power / signal cables

Light weight sonar cable - Type 5025

Inner Conductor 0,50 mm2 stranded bare copper conductor (7 ea.) Dielectric Foam polyolefin 1st Shield Tinned copper braid, coverage 85% 2nd Shield Tinned copper braid, coverage 85% Inner jacket Polyurethane jacket Strength member Aramidic yarn braid Outer jacket Polyurethane jacket. Colour yellow

Diameter 9,7 mm ±0,3 mm Weight in air 135 kg/ km nom. Weight in seawater 58 kg/ km nom. Strength member Breaking Load 25 kN Strength member Safe Working load 6 kN Min. bending radius 90 mm Depth rating 5000 meters

Operating voltage 400 V Test voltage 2000 V DC for 1 min.

Conductor resistance 14,5 ohm/ km Insulation resistance 5 ohm/ km Impedance 50 ohm ± 3 ohm Capacitance 94 pF/ m Attenuation 10 dB/ km at 1 MHz No. 2009880C - Rev. B - 02/12

Electrical Characteristics

Mechanical Characteristics

Construction Characteristics

15

Instrumentation cables

1 STP Data Cable - Type 4021

Shielded twisted pair 1,00 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a bare copper drain wire and aluminium/ polyester foil (1 ea.) Outer jacket Polyurethane jacket. Colour blue

Diameter 8,00 mm ±0,30 mm Weight in air 76 kg/ km nom. Weight in seawater 33 kg/ km nom. Min. bending radius, static 95 mm Min. bending radius, dynamic 120 mm Depth rating 3000 m

Operating voltage 750 V Test voltage 4000 V DC for 1 min.

Conductor resistance 20,0 ohm/ km Insulation resistance 500 Mohm* km (cond./cond.) 10 Mohm* 100 m (cond./shield) Capacitance 85 pF/ m nom. Impedance 65 ± 5 Ohm at 1-10 MHz Attenuation 4.5 dB/ 100 m at 1 MHz 11.5 dB/ 100 m at 10 MHz No. 2005744C - Rev. B - 02/12 16

Instrumentation cables

4 STP Data cable- Type 4588

Centre filler Textile filler

Shielded twisted pairs 1,00 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/ polyester foil (4 ea.) Filling compound The cable is filled with cable filling compound Shield Aluminium/polyester foil and tinned copper drain wire, coverage 100% Outer jacket Polyurethane jacket. Colour black

Diameter 14,00 mm ±0,50 mm Weight in air 240 kg/km nom. Weight in seawater 75 kg/km nom. Min. bending radius, static 90 mm Min. bending radius, dynamic 150 mm

Operating voltage 600 V Test voltage 4000 V DC for 1 min. (cond./cond.) 3000 V DC for 1 min. (cond./shield) 500 V DC for 1 min. (shield/shield)

Conductor resistance 20,0 ohm/ km Insulation resistance 10000 Mohm* km (cond./shield) 100 Mohm* 100 m (shield/shield) Capacitance 100 pF/ m No. 2002625C - Rev. F - 02/1217

Instrumentation cables 7 STP Data cable - Type 4700

Shielded twisted pairs 0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (7 ea.) Shield Aluminium/polyester foil and tinned copper drain wire, coverage 100% Outer jacket Polyurethane jacket. Colour blue

Diameter 12,70 mm ±0,30 mm Weight in air 205 kg/ km nom. Weight in seawater 115 kg/ km nom. Min. bending radius, static 120 mm Min. bending radius, dynamic 150 mm Depth rating 3000 m

Operating voltage 600 V Test voltage 3000 V DC for 1 min.

Conductor resistance 41,0 ohm/ km Insulation resistance 500 Mohm* km (cond./cond.) 100 Mohm* km (cond./shield) 10 Mohm* km (shield/shield) Capacitance 100 pF/ m Impedance 57 ± 5 Ohm at 1-10 MHz Attenuation 7.0 dB/ 100 m at 1 MHz 18.0 dB/ 100 m at 10 MHz No. 2005746C - Rev. B - 02/12

20

Instrumentation cables Instrumentation Cable - Type 6589

Conductors 1,00 mm2 bare copper conductor insulated with PE (4 ea.)

Inner jacket PVC jacket Shield Bronze braiding

Outer jacket Polyurethane jacket. Colour black

Diameter 9,80 mm ±0,30 mm Weight in air 140 kg/ km nom. Weight in seawater 62 kg/ km nom. Min. bending radius, static 130 mm Min. bending radius, dynamic 150 mm Breaking strength 1 kN (braiding only) Depth rating 6000 m

Operating voltage 600 V Test voltage 3000 V DC for 1 min.

Conductor resistance 20,0 ohm/ km Insulation resistance 5000 Mohm* km Capacitance 70 pF/ m Impedance 100 ohm at 100 kHz No. 2005752C - Rev. B - 02/12

21

Instrumentation cables

7 Conductor shielded cable 0,50mm2 - Type 5071

Strength member Aramid yarn insulated with PE (1 ea)

Conductors 0,50 mm2 bare copper conductor insulated with PE (7 ea.)

Shield Tinned copper braid, coverage 85% Outer jacket Polyurethane jacket. Colour black

Diameter 10,00 mm ±0,30 mm Weight in air 140 kg/ km nom. Weight in seawater 60 kg/ km nom. Breaking strength > 3600 N Min. bending radius, static 70 mm Min. bending radius, dynamic 100 mm Depth rating 3000 m

Operating voltage 750 V DC Test voltage 3000 V DC for 1 min.

Conductor resistance 41,0 ohm/ km Insulation resistance 10000 Mohm* km (cond./cond.) 100 Mohm* 100 m (cond./shield) 10 Mohm/ km (shield/shield) No. 2005760C - Rev. B - 02/12

22

Instrumentation cables

7 Conductor shielded cable - Type 5072

Conductors 1,50 mm2 bare copper conductor insulated with TPE. (7 ea.)

Shield Tinned copper braid, coverage 85% Outer jacket Polyurethane jacket. Colour black

Diameter 9,50 mm ±0,30 mm Weight in air 172 kg/km nom. Weight in seawater 100 kg/km nom. Min. bending radius, static 95 mm Min. bending radius, dynamic 115 mm Depth rating 3000 m

Operating voltage 480 V DC Test voltage 3000 V DC for 1 min.

Conductor resistance 14,0 ohm/ km Insulation resistance 100 Mohm* km No. 2005748C - Rev. B - 02/12

23

Instrumentation cables

12 Conductor shielded cable 0,50mm2 - Type 5121

Conductors 0,50 mm2 tinned copper conductor insulated with PVC. (12 ea.) Shield Aluminium/ polyester foil, coverage 100% Tinned copper braid, coverage 90% Outer jacket Polyurethane jacket. Colour black

Diameter 12,00 mm ±0,30 mm Weight in air 225 kg/ km nom. Weight in seawater 110 kg/ km nom. Min. bending radius, static 145 mm Min. bending radius, dynamic 180 mm Depth rating 3000 m

Operating voltage 300/ 500 V U/ Uo Test voltage 2000 V DC for 1 min

Conductor resistance 41,0 ohm/ km Insulation resistance 100 Mohm* km No. 2005750C - Rev. B - 02/12 24

Instrumentation cables

12 Conductor shielded cable 1,50mm2 - Type 5122

Conductors 1,50 mm2 bare copper conductor insulated with TPE. (12 ea.)

Shield Tinned copper braid, coverage 85% Outer jacket Polyurethane jacket. Colour black

Diameter 12,10 mm ±0,30 mm Weight in air 280 kg/ km nom. Weight in seawater 165 kg/ km nom. Min. bending radius, static 125 mm Min. bending radius, dynamic 145 mm Depth rating 3000 m

Operating voltage 480 V Test voltage 3000 V DC for 1 min.

Conductor resistance 14,0 ohm/ km Insulation resistance 100 Mohm* km No. 2005750C - Rev. B - 02/12 25

Fibre optic cables

Hybrid SM/ MM cable - Type 3784

Fibre optic element Steel tube (2,3mm OD) with eight single mode corning SMF 28e (9/125). Four multi mode Corning InfiniCor 600 or equivalent (50/125), filling compound LA444

(minimum 90% fill) With a polyethylene jacket - black - SM Colours: White, yellow, green, blue, red, orange, brown, grey

- MM Colours: Black, pink, violet, aqua

Conductors 1,0 mm2 (18 awg) tin plated copper conductor with dual wall insulation system. Primary jacket XL polyvinylidene fluoride. O.D. 2,23mm. (7 ea.)

Wrap Mylar tape Outer jacket Ray thane C 1,3 mm wall thickness

Outer jacket Red

Diameter  10,5 mm ±0,50 mm 

Operating temperature  ­20°C to 80°C 

Weight in air 171 kg/ km nom.

Weight in seawater 82 kg/ km nom.

Min. bending radius 100 mm static 150 mm dynamic

Depth rating 6000 metres

Operating voltage 2500 V (RMS)

DC Resistance @20C 20,4 ohm/km

Fibre Attenuation SM – dB/km 0,6 max @ 1310nm 0,4 max @ 1550nm MM – dB/km 2,9 max @ 850nm 0,6 max @ 1300nm

No. 2005742C - Rev. D - 02/12

Electrical and Fibre Optical Characteristics

26

Fibre optic cables

Optical cable - Type 4 SM ¨

Optical fibres Single mode fibre with Hytrel buffer. Plow steel 8 x 0,38 mm strength member and HDPE jacket (4 ea.) Jacket PUR jacket. Colour red

Diameter 9,0 mm

Min. bending diameter 110 mm static 150 mm dynamic Depth rating 6000 metres

Attenuation 0,45 dB/ km at 1310 nm 0,30 dB/ km at 1550 nm No. 2001589C - Rev. C - 02/12

27

Fibre optic cables

Electrical/Optical cable - Type 4MM 50/125 + 3 EL

Optical fibres 50/125/245 µm multi mode fibre with Hytrel buffer – 0,18 mm wall. Plow steel 8 x 0,38 mm strength member and Nylon jacket – 0,33 mm wall (4 ea.) Conductors 1,0 mm2 copper conductors insulated with PE (3 ea.) Jacket PUR jacket. Colour blue

Diameter 9,6 mm Min. bending diameter 120 mm static 160 mm dynamic

Voltage rating 600/1000 V Attenuation 3,8 dB/ km at 850 nm 1,8 dB/ km at 1300 nm Bandwidth 400 MHz* km at 850 nm 600 MHz* km at 1300 nm No. 2001590C - Rev. C - 02/12

28

Fibre optic cables

4 Fiber single mode 9/125 cable - Type 3409/B

Centre fill Aramidic yarn

Optical fibres   Single mode 9/125/245 µm optical fibres in unitube, 1,7 mm diameter. (4 ea.) Fibre colours: Red, white, green, white.

Inner jacket Polyurethane jacket.

Strength member Kevlar braiding

Outer jacket Polyurethane jacket. Colour red

Diameter  9,10 mm ±0,20 mm 

Weight in air 90 kg/ km nom.

Weight in seawater 23 kg/ km nom.

Min. breaking strength 2,5 kN

Min. bending radius, static 110 mm

Min. bending radius, dynamic 145 mm

Max. pressure resistance 300 bar

Depth rating 5000 m

Optical, trans massive and dimensional characteristics In accordance with ITU-T G652

Max. attenuation 0,40 dB/ km at 1300 nm 0,25 dB/ km at 1550 nm

No. 2005740C - Rev. C - 02/1229

Fibre optic cables

Electrical/Optical cable - Type 3444

Fibre optic element Loose tube with 4 multimode optical fibres 50/125 µm with Kevlar reinforcement   and polyolefin sheath. 3 mm diameter. Fibre colours: Grey, white, red, black.

Conductors 1,0 mm2 stranded tinned copper conductor insulated with polyofin. 3 mm diameter. Conductor colours: Blue, black, red, brown. (4 ea.)

Filler Filler element

Fibre optic element Loose tube with 4 single mode optical fibres 9/125 µm with Kevlar reinforcement   and polyolefin sheath. 3 mm diameter. Fibre colours: Blue, orange, green, brown.

Inner jacket Polyurethane jacket. Colour: Red

Strength member Kevlar braiding

Outer jacket Polyurethane jacket. Colour red

Diameter  15,50 mm ±0,40 mm 

Operating temperature  ­20°C to 80°C 

Weight in air 235 kg/ km nom.

Weight in seawater 42 kg/ km nom.

Min. breaking strength (Strength member) 15 kN

Min. bending radius 230 mm

Depth rating 5000 metres

Operating voltage 1000 Vdc

Max. attenuation 3,00 dB at 850 nm for multi mode fibres 0,80 dB at 1300 nm for multi mode fibres 0,40 dB/ km at 1300 nm for single mode fibres 0,25 dB/ km at 1550 nm for single mode fibres

No. 2006816C - Rev. B - 02/12

Electrical and Fibre Optical Characteristics

30

Special cables

Multipurpose coax cable - Type 0799

Coax 1,94 mm2 stranded bare copper wires insulated with PE- 1,40 mm wall. 0,08 mm2 bare copper wire shield and copper polyester tape. 1 ea.

Jacket   PE jacket – 0,98 mm wall 

Armour Inner layer: 24 x 0,95 mm wire GIPS Outer layer: 24 x 1,22 mm wire GIPS

Diameter 11,43 mm

Weight in air 469 kg/ km

Weight in seawater 379 kg/ km

Breaking strength 71,2 kN

Max. working load 17,8 kN

Min. bending radius 230 mm

Voltage rating 1900 V DC

Insulation resistance 3000 Mohm* km

DC resistance 9,8 ohm/km for coax conductor 6,9 ohm/km for coax shield

Impedance 40 ohm

Capacitance 131 pF/m

Attenuation 10,5 dB/km at 1 MHz 23,3 dB/km at 5 MHz

No. 2005755C - Rev. A - 02/1231

Special cables

Focus/ Triaxus cable - Type 0382

Conductors 0,24 mm2 (24 AWG) copper conductor insulated with PP (2 ea.)

Electro/Optical element 8,3/125/245 µm single mode optical fiber with Hytrel buffer, 0,92 mm² (18 AWG) HD  copper serve and PP belt (2 ea.)

Inner Jacket PE Jacket

Armour One layer of galvanized steel wires – 14 x 1,32 mm     One layer of galvanized steel wires – 24 x 1,07 mm 

Diameter 9,98 mm

Weight in air 389 kg/ km

Weight in seawater 322 kg/ km

Specific gravity 5.8

Min. breaking strength 71 kN

Working load 15 kN

Recommended bending radius 200 mm

Operating voltage 500 V for conductor 1200 V for electro/optical element

DC resistance 82,0 ohm/ km for conductor 21,3 ohm/ km for electro/optical element

Insulation resistance 3000 Mohm* km for conductor and electro/optical element

Attenuation 0,45 dB/ km at 1310 nm 0,35 dB/ km at 1550 nm

No. 2002641C - Rev. D - 02/12

Electrical and Fibre Optical Characteristics

32

Non stock cables

Sonar & Acoustic System Cables Historically side scan sonar systems were towed by multi-core steel or aramide armoured cables. Although these cable types are still an industry standard, there has been an upsurge in acoustic, digital and telemetry technology which demand a new approach to cable engineering. We supply the complete range of cables for acoustic applications including armoured coaxial cables for side

the most advanced acoustic systems.

Video System UmbilicalsThe advances in underwater vision systems have developed dramatically over the years. This has led to new designs in cables using sophisticated transmission systems with multiple broad band channels. We supply traditional diver, sewer inspection and well head TV system cables, however, we are

transmission systems for security systems, ROV & ROTV systems, underwater trenchers and ploughs.

ROV and Trencher UmbilicalsAs ROV systems get larger, more powerful and operate in deeper waters, the demand on the cable system becomes a critical issue. Fibre optic, high voltage umbilicals are now common place and we supply standard and special designs to this market. These include steel armoured lift umbilicals and aramide reinforced tether cables. Also part of our program are neutrally buoyant tethers for Tether Management Systems and smaller ROV systems. We have also designed and built special cables for long excursion (tunnel inspection).

Dynamic Cable Ancilliary ProductsTraditionally dynamic cables and terminations have been considered to be the “weak link” in the reliability of underwater systems. MacArtney has always viewed a dynamic cable as a system which includes connectors, mechanical terminations, protection, buoyancy, sheaves, handling systems etc. To support our in-house engineered designs, we also supply a complete range of winch systems, slip rings, cable moulding, underwater electrical and optical connectors, mechanical terminations, penetrators, cable buoyancy, sheaves and cable status indicators fully supported by our in-house

33

Terminations

Standard Steel Termination Our standard shackle or fork terminations are safe and reliable methods of connecting cable to towed underwater vehicles or for lifting a heavy object, such as a down-hole camera system. Terminating and moulding the cable to a connector ensures a watertight connection from cable to system. MacArtney stocks standard terminations for steel armoured or Kevlar armoured cables with diameters of 6 to 14mm and loads of up to 1500kg. We also have extensive experience of designing terminations for loads of up to 100 tonnes.

Bend Restrictors & Bend StiffenersBend restrictors and stiffeners are designed to minimse sharp cable bends, protecting them from stress damage and kinks. They mechanically limit the bend and prevent unwanted tension.

Chamber Terminations MacArtney chamber terminations connect a cable to a specially designed connector. The chamber transfers the entire force from the cable to the steel parts of the termination, maintaining the safe working load of the cable throughout the connection. The chambers

makes it possible to replace the connector or cable relatively easily re-using the metal termination parts.

Oil Compensation

either with an internal bladder or an external reservoir. They can be

PE MouldingsPE moulding is a secure and economical method of connecting PE jacketed cables and connectors without the need for an oil compensated system. A special hot moulding machine forces PE moulding material into the moulding form under high pressure,

34

Extension & Take Out of Fibre OpticExtension and “take out” terminations are used when cables have been damaged or if they need to be extended to reach new locations.

main cable. The terminations are usually designed to have the same working load and depth rating as the cable, and are often designed with a lifespan of 10 to 15 years in seawater.

PenetratorsMacArtney makes a broad range of standard and customer-designed penetrators for use at all water depths – even full ocean depth. Penetrators are designed to connect systems to infrastructure, and

optic transmissions. They are available with or without internal water

cables, or combinations of both. MacArtney penetrators are available with a range of housing types or with custom made housing. They are delivered with 1 metre pigtails and ST connectors as standard.

Optolink Fibre penetrator

withstand the challenges of system infrastructure at pressures of up to 600 bars. It is completely blocked on both sides, so even if the cable is damaged, water will not enter. It is available with 3 types of housing;

custom made housing. They are interchangeable and can be replaced

delivered with 1 metre pigtails and ST connectors as standard.

FITA Field Installable Termination Assembly

system that assembles a harness cable or array of harness cables to a cable, typically from subsea control systems to an umbilical. The FITA can be assembled on site without the need for mouldings.

termination entirely watertight at every level. FITA terminations are oil compensated, maintaining the same pressure inside the termination as outside. This allows them to operate at 600 bars without the need

4-6 months.

35