π0 cross-section analysis€¦ · cross section with different t’ bin size kin 601 (e0=8.52 gev)...

22
π 0 cross-section analysis DVCS collaboration meeting Bishnu Karki Feb 01, 2020

Upload: others

Post on 30-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

π0 cross-section analysis

DVCS collaboration meetingBishnu Karki

Feb 01, 2020

Page 2: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

2

t and tmin

Eric definition vs one in Malek’s File

tmin

and t redefined during analysist : Difference between Malek’s file and “t” I computed (using Eric’s definition) is below “t” resolution (Good in t)tmin

: Simulation has some other definition than what Charles’s suggested ( ELOG 585)

Definition in simulationCharles’s definition

tEric

– tMalek’s File

Page 3: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

3

Unphysical events ((M2 < 0)● Kin 601 => 0.02 %● Kin 603 => 0.5%

Kin 601Kin 603

Smearing the simulation

Done is two steps:1) First determine μ and σ (keeping theta at nominal value)2) Second fix μ and σ and then smear θ

Page 4: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

4

Electron selection

● PID [H.Rashad]● Cherenkov => (>150 channel)● Pion rejector =>(pr1/w1>200) && (pr1/w1 + pr2/w2)>600

● Acceptance R-cut [A. Johnson]● Vertex[-6.5 cm, 6.5 cm]● Single track [4S0M + 3S1M ] [H.Rashad]

Correction for dead time, tracking efficiency, and trigger efficiencies are well in place

A. Johnson

AcceptancePID

Al

}

Page 5: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

5

π0 event selectionCorrelation between missing mass and invariant mass

1 2

M. Mazouz (https://hallaweb.jlab.org/dvcslog/Pion/131

Corr:Kin 601=> -13.7 GeVKin 603 => -17.6 Gev

Page 6: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

6

Exclusivity cuts

ep e’p’π0 X => well below to eliminate the SIDIS contamination

Page 7: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

7

π0 event selectionAccidental subtraction

e- �1 �

2

Page 8: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

8

Cross-section extraction formalism(π0 production)

Krv : Bin migration probability

σexp : Error in data (accidental subtraction considered)

For helicity dependent term

Page 9: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

9

Cross section with different t’ bin sizeKin 601 (E0=8.52 GeV)

● 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to account the bin migration)

● Migration is preferentially in one direction

12

3

1

2

3

Page 10: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

10

Cross-section parametersKin1High Malek’s Data(E0=5.55 GeV)

● My code for cross-section can reproduce Malek’s result within statistical uncertainty

dσTTdσ

TL

d(σT+ Ɛσ

L)

Page 11: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

Systematic studyKin 601/603

1) Exclusive cuts 2) Clustering threshold3) Photon E cut4) Virtual radiative correction (approximation for DVCS)5) Correction from 3 clustering6) May be comparison with G.R Goldstein, J.O Hernandez S. Liuti

Page 12: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

12

Systematic study (Exclusive cut)Kin 603

Minv fixed at “2” (3σ) M2 low end fixedM2 high end at different position

Minv fixed at “2” (3σ) M2 high end fixedM2 low end at different position

M2 fixedMinv at different spot “1” and “3”

Page 13: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

13

Systematic study (Exclusive cut)Kin 601

Minv fixed at “2” (2σ) M2 low end fixedM2 high end at different position

Minv fixed at “2” (2σ) M2 high end fixedM2 low end at different position

M2 fixedMinv at different spot “1” and “3”

Page 14: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

14

Systematic study (cut on photons E)Kin 603

Cut ● both photon > Threshold E

➔ Only σT+ Ɛσ

L is sensitive

➔ Cross-section is consistent w.r.t E cut

Page 15: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

15

Systematic study (cut on photons E)Kin 601

Cut ● both photon > Threshold E➔ Only σ

T+ Ɛσ

L is sensitive

➔ Systematic up to 4%➔ No reasonable explanation

through variation in kinematic variables (Q2, xB Γ,..)

Page 16: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

16

Systematic study (Clustering threshold)Kin 603

Cuts on photon E: ● E

1 = E

2 > Clustering Threshold (No any cut on photon E in analysis)

● Cross-section results are in good agreement

Page 17: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

17

Systematic study (Clustering threshold)Kin 601

Cuts on photon E: E

1 = E

2 > 1.5 GeV (Additional cut on photon E > Clustering threshold)

Page 18: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

18

Cross-section parametersKin 601 (E0=8.52 GeV)

● Model used data at small xB and t

● σL from model is

consistent to zero

Page 19: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

19

Cross-section parametersKin 603 (E0=10.59 GeV)

● The interference term σ

LT suggest σ

L is larger

● These data will improve the parametrization of the GPDs

Page 20: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

20

Error budget

● 4% systematic in DIS = {PID, R-Function, Luminosity, Solid angle, trigger+tracking efficiency, virtual radiative correction}

● 4 % deviation from world data ➔ May not effect DVCS trigger

Source Contribution

DIS (e-) 4%

Exclusive cuts 0.5%

Threshold E cutand clustering

0 + 0 (603)Point to point up to 4% each (601)

Trigger loss (seen in DIS)

?

Beam Polarization

1%

Page 21: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to

THANK YOU !

Page 22: π0 cross-section analysis€¦ · Cross section with different t’ bin size Kin 601 (E0=8.52 GeV) 5 t’ bin analysis is equivalent to 3 bin analysis and looking at middle bin (to