0 instruction manual control and switch panel dt 201 … · 2011-03-08 · 6 situation: 18.07.2005...

24
© 2005 Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de SDT-0018-02EN (Valid from software version 2.16) 830.563 Situation: 18.07.2005 0 Instruction Manual Control and Switch Panel DT 201 B Instruction manual Control and switch panel DT 201 B Table of contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 Description and appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 6 Starting up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 8 Shutting down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 9 Technical faults, possible causes and remedies . . . . . . . . . . . . . 21 10 Circuit diagram - for specialist workshop only . . . . . . . . . . . . . . . 22 11 Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 12 Fault report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Upload: others

Post on 08-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

© 2005 Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de

SDT-0018-02EN (Valid from software version 2.16) 830.563 Situation: 18.07.2005

0 Instruction Manual Control and Switch Panel DT 201 BInstruction manual

Control and switch panel DT 201 B

Table of contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3 Description and appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . .3

4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6 Starting up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

8 Shutting down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

9 Technical faults, possible causes and remedies . . . . . . . . . . . . .21

10 Circuit diagram - for specialist workshop only . . . . . . . . . . . . . . .22

11 Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

12 Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Page 2: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

2 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

1 IntroductionThis instruction manual contains important information for the safe operation of the control and switch panel. It is essential to read and to follow the given safety information.

The instruction manual should always be kept in the motorhome/caravan. All safety information must be passed on to other users.

The reproduction, translation and duplication of this manual, even in parts, is not allowed without written authorization.

2 Safety informationThe design of the control and switch panel is state-of-the-art and according to approved safety technology regulations. Nevertheless, if the safety informa-tion in this instruction manual is not closely followed, persons might be injured or the control and switch panel might be damaged.

Do not use the control and switch panel if it is not in technically good order and condition. The instruction manual must be followed.

Any technical faults affecting the safety of persons or of the control and switch panel must be dealt with immediately by qualified personnel.

� Failure to comply with this sign may lead to the endangerment of per-sons.

� Failure to comply with this sign may damage the unit or the connected con-sumers.

� This sign indicates recommendations or special features.

� The electrical system of the motorhome or the caravan has to meet cur-rent DIN, VDE and ISO regulations. Manipulations of the electrical sys-tem will endanger the safety of persons and the vehicle, and are there-fore prohibited.

� Never make any modifications to the control and switch panel.

� Connection work is to be carried out in tensionless condition only.

� The electrical connection may only be established by qualified person-nel and must be carried out according to the Schaudt installation instructions.

� If the living area battery is totally discharged or overcharged for a lengthy period, it will be irreparably damaged.

� Switch off the 12 V main switch when you leave the vehicle. This prevents the living area battery from unnecessarily discharging.

� Before starting to drive, check if the step and the supports are retracted and if the roof hood is closed. If the sensors are defective or if the D+ signal is missing, the warning signal can fail.

Page 3: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 3

Instruction Manual Control and Switch Panel DT 201 B

3 Description and appropriate useThe job of the control and switch panel DT 201 B is to control the electrical functions in the living area of the motorhome and display various values such as capacity, voltages, battery currents and water tank levels.

This system includes:� An Electrobloc, consisting of a charger module, the 12 V distribution and

the fuses for each circuit� Tank sensors for measuring the level in the water tanks� An outside temperature sensor

Fig. 1 Control and switch panel DT 201 B1 12 V main switch button2 Tank button3 Battery button4 Basic display button5 Display window6 "MENUE" button, setting menu7 "+" button (increase indicated value)8 "–" button (reduce indicated value)9 "OK" button (selection/confirm settings)

Buttons The various displays and menus are selected and settings made using the 8 buttons on the front of the control and switch panel.

The control and switch panel must first be switched on using the 12 V main switch button, before the other buttons can be used. When the control and switch panel is switched on, the basic display is visible.

If the basic display, tank or battery button is pressed, the corresponding dis-play appears and is illuminated. 20 seconds after pressing the button for the last time, the basic display appears. It is not illuminated.

The "MENUE" button must be pressed for more than 3 seconds to arrive at the desired setting menu.

1 2 3 4 5 6 987

SDT00092

� The control and switch panel can only be switched on, if the living area bat-tery voltage is above 11.0 V.

� For more information, see the section 5.7.

Page 4: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

4 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

Symbols on the display Symbols, measured values and settings of the selected display are indicated in the display window.

Fig. 2 Display window1 Defroster switched on2 Spare cylinder in use3 Living area battery/inside temperature4 Solar current5 Setting menu6 Battery and filling level alarm7 Call up next page8 Optical display for buzzer/warning that buzzer is switched off9 12 V Off display (3 seconds)

10 230 V power supply is connected11 Water tank12 Waste water tank13 Fault display for battery, filling level sensors, temperature sensors14 Starter battery/outside temperature/step

Calling up the next page If the arrow is visible in the display window, the next page can be called up with the basic display, tank, battery and menu buttons.

4 Technical data

Operating voltage 12 V (10 - 14.5 V), powered via Electrobloc

SDT00094

21

14 1213

109

11

4 5 63 7 8

Page 5: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 5

Instruction Manual Control and Switch Panel DT 201 B

5 Operation

5.1 Switching the 12 V power supply for the living area on and off

12 V main switch button The 12 V main switch button switches all consumers and the control and switch panel on and off.

Exceptions:� Floor light/step� Frost protection valve� Heater� Spare 4� Compressor refrigerator/AES refrigerator

Switching on � Press the 12 V main switch button. The illuminated basic display appears and the system is ready for use. The basic display is illuminated for 20 seconds. If there is an alarm message, this is also indicated in the basic display.

Switching off � Press the 12 V main switch button. The system shuts down. The text "12 V OFF" appears for 3 seconds.

5.2 Using the basic display

Basic display button The basic display gives information on mains indicator, step, special equip-ment and temperature as well as date and time.

� Press basic display button.The 1st page of the basic display appears.

Fig. 3 Basic display

230 V mains indicator The 230 V mains indicator symbol is displayed, if the input of the Electrobloc is live and if the control and switch panel has been switched on using the 12 V main switch.

� Switch off the 12 V main switch when you leave the vehicle. This prevents the living area battery from unnecessarily discharging.

SDT00095

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated.

Page 6: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

6 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

Spare cylinder (optional) For additional equipment Truma Duomatic L plus:The spare cylinder symbol is displayed when one of the two gas cylinders is empty.

The spare cylinder symbol flashes if the second gas cylinder is also empty. The "ALARM" message appears in the basic display.

For additional equipment Truma Triomatic:The spare cylinder symbol is displayed when the gas cylinder in use is empty.

Defroster (optional) For additional equipment Truma Duomatic L or Truma Triomatic:The "Eis-Ex" (defroster) symbol is displayed when the defroster unit is switched on.

Step The step symbol is displayed when the step is extended.Before commencing the journey, the step must be retracted.

If the step is extended and the engine is started, a loud warning signal is emit-ted and the buzzer symbol appears on the display.

If the sensors are defective or if the D+ signal is missing, the warning signal can fail. Before commencing the journey, the driver must therefore check if the step is retracted.

5.2.1 Checking the temperatures

Basic display button � Press the basic display button twice briefly.

The inside and outside temperatures are indicated on the 2nd page of the basic display. The display range is between -40 °C and +60 °C.

� For more information, see the instruction manual for the additional equip-ment.

� Before commencing the journey, check if the step is retracted.

� For more information, see the section 5.7.

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated.

Page 7: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 7

Instruction Manual Control and Switch Panel DT 201 B

5.2.2 Settings in the basic menuThe defroster option can be switched on and off in the basic menu. Time, date and nominal battery capacity can also be set and software version and parameter number displayed.

"MENUE" button � In the basic display, press the "MENUE" button for more than 3 seconds.The 1st page of the basic display appears. The adjustable values flash in the display.

� If the step alarm is emitted, it can be switched off on the 1st page (page is only visible if the warning signal is emitted).

� If the defroster unit is installed, the defroster option can be switched on and off on the next page (page is only visible if the defroster unit is installed).

� The time can be set on the next page.

Fig. 4 Basic menu

� The date can be set on the next page.� Software version and parameter number are displayed on the next page.

� Change the flashing value with the "+" or "–" button.

� Press "OK" button.The entry of the new value is confirmed, the next adjustable value begins to flash and can be changed or confirmed.

� Press "MENUE" button.The next page is displayed.

� To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display.

SDT00098

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. Entries that are not con-firmed with "OK" are not saved.

� Changed values are only saved if the entry was confirmed using the "OK" button.If one switches to another display before pressing the "OK" button, the changed values are not saved.

Page 8: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

8 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

Defroster unit The defroster unit can be switched on and off or set to automatic operation in the basic menu. Depending on the setting, "ON", "OFF" or "AUTO" is indicat-ed in the display window. This menu is only displayed if the defroster unit is installed.

In automatic operation, the defroster unit is automatically switched on if the outside temperature falls below +7.5 °C and automatically switched off if the temperature rises above +7.5 °C.

Setting the time � Press the "MENUE" button for more than 3 seconds.The basic display is displayed.

� Press the "MENUE" button several times until the "TIME" page of the basic menu is displayed. The hour display flashes.

� Set the hours with the "+" or "–" button.

� Press "OK" button.The hour entry is confirmed. The minute display flashes.

� Set the minutes with the "+" or "–" button.

� Press "OK" button.The minute entry is confirmed. The time is set.

Setting the date � Press the "MENUE" button several times until the "DATE" page of the basic menu is displayed. The year display flashes.

� Set the year with the "+" or "–" button.

� Press "OK" button.The entry of the year is confirmed. The day display flashes.

� Set the day with the "+" or "–" button.

� Press "OK" button.The entry of the day is confirmed. The month display flashes.

� Set the month with the "+" or "–" button.

� Press "OK" button.The entry of the month is confirmed.

Software version andparameter number

� Press the "MENUE" button several times until the software version and the four-digit parameter number are displayed. These settings cannot be changed.

� To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display.

� Press "OK" button.

� Both defroster outputs are designed only for operation with the liquid gas control units Truma Duomatic L plus or Truma Triomatic and may only be used together with these units. The maximum load current for each output is 0.4 A.

� Software version and parameter number are required for queries at the dealer or customer service. Always have these settings ready for queries.

� For the correct functionality, the parameter number must be modified if special equipment is installed at a later date. You can obtain further infor-mation at your dealer or at Schaudt GmbH customer service.

Page 9: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 9

Instruction Manual Control and Switch Panel DT 201 B

5.3 Battery displayThe battery display indicates the battery capacity and the load current of the living area battery as well as the battery voltage of living area battery and starter battery. If available, the solar current of living area battery and starter battery is also displayed.

The control and switch panel is equipped with a real level display for the living area battery. The display of the battery capacity gives direct information on how much power is stored in the battery.

Example: The battery has been fully charged (100 %) and the motorhome has not been connected to a 230 V power supply for 3 days. The display indicates 40 %. That means that the battery can supply the motorhome with power for about 2 more days.

Other functions The following functions are also integrated:� Automatic setting of the capacity display to "full" on reaching a full battery

charge� Warning if the battery capacity falls below 15 % of the nominal level. For

more information see section 5.3.5� Automatic determination of the maximum possible battery capacity (in Ah)

for defined discharging of the battery� Warning at the end of the battery service life (max. capacity reached: only

50 % of the nominal capacity)� Charge request if the last full charge was more than 20 days ago� Setting of the nominal capacity by the motorhome user (e.g. if a higher bat-

tery capacity is retrofitted)

5.3.1 Checking battery capacity and load current

Battery button � Press battery button.Battery capacity and charge current of the living area battery appear on the 1st page of the battery display.

Fig. 5 Battery display

SDT00097

Page 10: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

10 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

The battery capacity can be displayed in ampere hours (Ah) and percent (%).

Switching between units � Press "OK" button.The display of the battery capacity switches between the units ampere hours (Ah) and percent (%).

The charging current of the living area battery is shown in amps (A).

Positive values indicate the charging current. Negative values indicate the discharge current.

The battery display takes all types of battery charge into account in connec-tion with the Electrobloc EBL 101:� Via the charger module of the 230 V mains� Via the cut-off relay of the alternator while driving� Via a solar charge regulator for the solar cells connected to the system

5.3.2 Checking the battery voltage

Battery button � Press battery button twice briefly.The voltages of living area battery and starter battery appear on the 2nd page of the battery display.

Voltage in the living area battery

Voltage in the starter battery

The off-load voltage of the starter battery is only displayed if the engine is switched off and if no consumers are using the starter battery.

� The illumination of the display requires approx. 0.4 A. This illumination cur-rent is added to the discharge current and displayed.

� In order to register the entire power consumption, all consumers must be connected to the Electrobloc. If consumers are connected directly to the battery, the Schaudt system cannot register their power consumption. The indication of current, battery capacity and charge request are not correct in such an event.

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. Entries that are not con-firmed are not saved.

� In mobile operation, the voltage of the starter battery is indicated slightly too low, if the refrigerator is in use with 12 V. If the refrigerator is switched off or operated using gas, the voltage display of the starter battery is cor-rect. In stationary operation, the voltage of the starter battery is also dis-played correctly.

Page 11: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 11

Instruction Manual Control and Switch Panel DT 201 B

The following table will help you correctly interpret the living area battery volt-ages displayed by the control and switch panel. These values apply to actual operation, not off-load voltage and for lead gel batteries only.

1) depending on the current load

Checking the condition ofthe battery

Measuring the off-load voltage is an additional method of assessing the con-dition of the battery. Off-load voltage is the voltage of the charged battery in a passive state, with no current being supplied or drawn.

Take the measurement several hours after the last charging. In the meantime, no significant load should have been placed on the battery, which means no current should have been drawn from it. If the off-load voltage of the battery is less than 12.0 V, there is a risk of total discharge.

The following table will help you interpret the off-load voltage displayed. These values apply for lead gel batteries.

Battery voltage Description

10.5 or less � Risk of total discharge� The battery monitor switches off all

consumers (apart from the frost protection valve)

11 V or more The 12 V power supply can be switched on using the main switch

10.5 V to 12 V � If the voltage falls below 12 V, the battery alarm is triggered

� If the voltage remains under 10.5-12 V 1) for more than 1 minute, the battery capacity is set to zero

� If the voltage remains under 10.5-12 V 1) for more than 5 minutes, the system is switched off

12 V to 13.2 V Battery off load

More than 13.2 V Battery is being charged: Main charge

13.8 V constant Trickle charge voltage

14.3 V Final charging voltage (equalising charge)� 1 h for lead acid battery� 8 h for lead gel battery

� If the living area battery is totally discharged or overcharged for a lengthy period, it will be irreparably damaged.

� If the 12 V power supply is overloaded, switch off some of the consumers.

� Inactive consumers can gradually discharge the battery.

Values for off-load voltage Charging condition of the battery

12 V 0 %

12.2 V 25 %

12.3 V 50 %

More than 12.8 V Full

Page 12: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

12 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

Charge requestCHARGE !

The batteries should be fully charged every 4 weeks for a long service life.

As a reminder a charge request is displayed 20 days after the last equalising charge.

� Connect the motorhome to the 230 V power supply.The batteries are charged.

5.3.3 Displaying the solar current (optional)

Battery button The solar current display is only possible with a solar charge regulator type LRS... of Schaudt GmbH.

� Press battery button three times briefly.The solar currents of living area battery and starter battery appear on the 3rd page of the battery menu:

Solar current display of the living area battery

Solar current display of the starter battery

� To exit the display, press any button or wait for 20 seconds until the dis-play automatically switches to the basic display.

5.3.4 Displaying the maximum battery capacity of the living area batteryThe maximum battery capacity of the living area battery "Ah max" is displayed in the battery menu, but it cannot be set. The maximum capacity is set at the factory to 80 % of the nominal capacity. The control and switch panel also recalculates the battery capacity after every complete charging cycle (total charge and total discharge) and indicates the current value. This display applies only to the living area battery.

� Press battery button once briefly.

� Press the "MENUE" button for more than 3 seconds.The maximum battery capacity "Ah max" of the living area battery appears on the 1st page of the battery menu.

� To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display.

� For more information see section 5.7 as well as the instruction manual for the Electrobloc.

� For more information, see the section 5.7.

Page 13: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 13

Instruction Manual Control and Switch Panel DT 201 B

5.3.5 Settings in the battery menu

Displaying/setting thebattery capacity

The nominal battery capacity "Ah nom" can be adapted e.g. on retrofitting a battery. The setting range is between 50 Ah and 495 Ah (K100 value). The standard setting ex works is 90 Ah.

� Press battery button once briefly.

� Press the "MENUE" button for more than 3 seconds.The 1st page of the battery menu is displayed. The maximum battery capacity "Ah max" is displayed.

� Press "MENUE" button a second time.The 2nd page of the battery menu is displayed. The display of the battery capacity flashes.

� Enter the new battery capacity of the living area battery with the "+" or "–" button. It can be read off at the battery as K value. If no K100 value is indi-cated, the K20 value can be read off and multiplied by 1.125.

� Confirm the set value with the "OK" button.

� To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display.

5.4 Battery monitor

Automatic disconnector The battery monitor compares the living area battery voltage to a reference voltage. Monitoring is continued, even when the control and switch panel is switched off.

Depending on the current drain an alarm message is displayed or the system is shut down sooner or later. This improves protection against total discharge of the battery.

As soon as the battery voltage falls below 10.5 V to 12 V (depending on the discharge current), an alarm message appears in the display window. As soon as the battery voltage falls below 10.5 V, all 12 V consumers are imme-diately switched off. Only the frost protection valve is still powered. The con-trol and switch panel also shuts down. Before shutting down, all switching conditions and the battery capacity value are saved. The automatic discon-nector is not triggered by short-term low voltage, caused by high current when switching on consumers.

If an overload or an insufficiently charged living area battery causes the volt-age to fall so low that the automatic disconnector is triggered, any consumers which are not essential should be switched off.

You may be able to switch on the 12 V power supply for a short time.

� Press the 12 V main switch button.The 12 V power supply is switched on.

� Changed values are only saved if the entry was confirmed using the "OK" button.If one switches to another display before pressing the "OK" button, the changed values are not saved.

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated.

Page 14: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

14 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

If the battery voltage remains below 11.0 V, you cannot switch on the 12 V power supply. The battery symbol and "CHARGE !" flash. The battery voltage is also displayed.

Fully charge up the living area battery as soon as possible.

5.5 Tank displayThe tank level can be indicated and the tank alarm switched on and off in the tank display.

5.5.1 Checking the tank level

Tank button � Press tank button.

Fig. 6 Tank display

The tank level is indicated as a numerical value in steps of 0 %, 25 %, 50 %, 75 % and 100 % and also as graphical symbol with 1 to 4 filling level marks.

Filling level of the water tank

Filling level of the waste water tank

� The saved switching conditions and the battery capacity value are restored on switching the unit on.

� For more information, see the section 5.7 and the table "Battery voltage".

SDT00096

Page 15: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 15

Instruction Manual Control and Switch Panel DT 201 B

The following table will help you correctly interpret the tank levels indicated by the symbols.

5.5.2 Settings in the tank menu

Tank alarm The tank alarm can be switched on and off in the tank menu.

� In the tank display, press the "MENUE" button for more than 3 seconds.The tank menu is displayed.

� Switch the tank alarm on or off with the "+" or "–" button.When the tank alarm is switched on, "ON" appears in the display window. When the tank alarm is switched off, "OFF" appears.

� Press "OK" button.The entry is confirmed.

5.6 Tank monitorThe tank monitor checks the water tank and waste water tank levels. This check is carried out every minute or on switching to the tank display. As soon as the water tank is empty or the waste water tank is full, the tank alarm is triggered.

The water tank is not monitored if the 12 V power supply of the consumers is switched off and while driving.

Symbol on display Tank level

Full or almost full

Roughly 3/4 full

Roughly 1/2 full

Roughly 1/4 full

Empty or almost empty

� If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated.

� For more information, see the section 5.7.

� For more information, see the section 5.7.

Page 16: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

16 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

5.7 Alarm messagesAlarm messages are indicated in the basic display by a flashing warning tri-angle and the corresponding symbol. In addition, the display window lights up for 20 seconds. More information on the alarm message is displayed in the battery menu and tank menu.

If there are multiple alarm messages, they are indicated simultaneously with the corresponding symbols.

5.7.1 Living area battery alarmThe battery alarm is triggered if the living area battery is nearly totally dis-charged or if the battery exceeds its gassing limit during the charging process due to overvoltage (Ubatt > approx. 14.6 V).

Total discharge If the living area battery voltage falls below the critical limit of 12 V to 10.5 V (depending on the current drain), the warning triangle and the word "ALARM" flash in the basic display.

The living area battery symbol and the charge request "CHARGE !" also flash.

� Switch off all consumers.

� Recharge the living area battery by driving or by connecting it to the 230 V mains.

Overvoltage If there is overvoltage and therefore a risk of the living area battery falling below its gassing limit (Ubatt > approx. 14.6 V), the warning triangle and the word "ALARM" flash in the basic display.

The living area battery symbol and the charge request "CHARGE !" also flash. The battery voltage value flashes in the display.

� Interrupt the charging of the battery, disconnect the battery from the 230 V power supply.

� Call customer service.

� If the living area battery is totally discharged for a lengthy period, it will be irreparably damaged.

� If the voltage is too high, the living area battery will be irreparably dam-aged.

� If the battery is empty, the control and switch panel cannot be switched on. As soon as the 12 V main switch button is pressed, the charge request "CHARGE !" and the battery symbol flash. The motorhome symbol and the battery voltage are also indicated.

� For more information see section 5.4, the table "Battery charge" as well as the instruction manual for the Electrobloc.

� For more information see section 5.4, the table "Battery charge" as well as the instruction manual for the Electrobloc.

Page 17: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 17

Instruction Manual Control and Switch Panel DT 201 B

5.7.2 Battery capacity alarm for the living area battery

CHARGE ! The battery capacity alarm is triggered when the capacity of the living area battery falls below 15 % of the nominal capacity.

The motorhome symbol is indicated in the basic display with a flashing battery symbol. The battery display also indicates the battery capacity and the charge request "CHARGE !".

� Recharge the living area battery by driving or by connecting it to the 230 V mains.

5.7.3 Charge request (instruction)

CHARGE !DATE

The motorhome symbol is indicated in the basic display with a flashing battery symbol 20 days after the last equalising charge.

The battery menu also displays the charge request "CHARGE !", the word "DATE" and the battery capacity.

The battery should be fully charged every 4 weeks for 24 hours to maintain its full capacity.

� Fully charge the living area battery by driving or by connecting it to the 230 V mains.

5.7.4 Battery defect message for the living area battery

DEFECT Batteries lose their capacity due to ageing and wear.

The battery defect message is displayed as soon as the maximum capacity falls below 50 % of the preset nominal capacity "Ahnom". The motorhome symbol with a flashing battery symbol and the message "DEFECT" are indi-cated in the basic display. The living area battery has reached its maximum service life.

� Check the battery and install a new living area battery, if required.

5.7.5 Message for undefined battery capacityIf the charge status of the battery is not known (e.g. after starting up the sys-tem for the first time or after changing the batteries), a "?" is displayed as capacity value. In addition, the charge request "CHARGE !" is displayed.

� Recharge the living area battery by connecting it to the 230 V mains for at least 24 hours.

� After completion of the charging process, disconnect the battery from the mains.

� Push any button.

After approx. 30 seconds the "?" disappears.

� For more information see the instruction manual for the Electrobloc.

Page 18: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

18 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

5.7.6 Tank alarmIf the water tank level falls below 12 % or if the waste water tank level exceeds 87 %, the warning triangle, the word "ALARM" and the tank symbol flash in the basic display.

The tank symbol and the tank level percentage indicator also flash in the tank display.

� Fill up water tank or drain waste water tank.

5.7.7 Step alarm

Before commencing the journey, the step must be retracted. If the step is not retracted, a loud warning signal is emitted and the buzzer symbol appears on the display when the engine is started.

If the sensors are defective or if the D+ signal is missing, the warning signal can fail. Before commencing the journey, the driver must therefore check if the step is retracted.

False step alarm In exceptional cases, there can be a false alarm: The step alarm is triggered, even though the step is retracted.

If such a malfunction occurs, the acoustic warning signal can be switched off after starting the engine.

� In the basic display, press the "MENUE" button for more than 3 seconds.

� Set the buzzer to "OFF" with the "+" or "–" button of the basic menu.

� Confirm the entry with "OK".

� To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display.

� Have the malfunction rectified by the dealer.

5.7.8 Mains alarmIf the 230 V power supply fails or if it is disconnected from the motorhome, the 230 V symbol flashes.

As soon as the 230 V power supply has been restored, the symbol lights up and remains illuminated.

The symbol goes out as soon as the engine is started.

Switching off the flashingsymbol

� Press "OK" button.The mains alarm is confirmed. The symbol goes out.

� If the water tank remains empty due to an external water supply, the tank alarm can be switched off.

� For more information, see the section 5.5.

� Before commencing the journey, check if the step is retracted.

� The acoustic warning signal must be switched off after every engine start, until the malfunction has been rectified.

Page 19: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 19

Instruction Manual Control and Switch Panel DT 201 B

5.7.9 Gas alarmFor additional equipment Truma Duomatic L plus: If one of the two gas cylin-ders is empty, the spare cylinder symbol appears in the basic display. As soon as the second gas cylinder is empty, the spare cylinder symbol and the "ALARM" message appear.

5.7.10 Tank sensor fault messageIf there is a malfunction of the water or waste water sensors, a "?" flashes in the tank display.

� Clean the tank sensors of the respective tank.

If the fault message is still displayed after cleaning, customer service must be informed.

5.7.11 Temperature fault messageIf there is a malfunction of the temperature sensors or if a temperature is not within the range of between -40 °C and +60 °C, a "?" is indicated in the tem-perature display.

5.7.12 Date message

DATE If no date has been entered in the basic menu, the word "DATE" flashes. The date display is required for the capacity display to work properly.

6 Starting upThe control and switch panel DT 201 B can only be started up with the Elec-trobloc EBL 101 and the accessories for measuring the water tank levels.

Starting up the system � Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery on). Follow the instruction manual of the Electrobloc.

� Press the 12 V main switch on the control and switch panel.

After shutting down If the battery is disconnected from the system (battery cut-off switch is turned off on the Electrobloc or a battery pole is disconnected): Check the off-load voltage of the battery immediately after start up. Do not connect the vehicle to the 230 V mains, do not start the engine and do not switch on any consum-ers until the off-load voltage of the battery has been checked.

After an off-load time of maximum 6 months, the battery voltage should be above 12.7 V if the battery was fully charged before shut down. If voltage is below 12.0 V then the battery might be defective and need to be replaced.

� After switching on the battery cut-off switch or after changing batteries: Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers.

� Connection work is to be carried out in tensionless condition only.

Page 20: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

20 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

7 MaintenanceThe control and switch panel requires no maintenance.

Cleaning Clean the front plate of the control and switch panel with a soft, slightly damp cloth and a mild detergent.Never use spirit, thinners or similar substances.Do not allow any fluid to penetrate the inside of the control and switch panel.

8 Shutting down

Switch off the system if you are not going to use the motorhome for a lengthy period (for example during the winter).

Shutting down the systemfor up to 6 months

Fully charge up the living area battery before shutting down the system. The living area battery is then protected against total discharge. This applies only if the battery is intact. Follow the instructions of the battery manufacturer.

Carry out the following work steps in the correct order:

1. Switch off the 12 V main switch on the control and switch panel.

2. Turn off the battery cut-off switch on the Electrobloc.

Shutting down the systemfor more than 6 months

Fully charge up the living area battery and remove the connecting terminals on the battery poles. Carry out the following work steps in the sequence men-tioned below. The battery alarm is then no longer active.

Disconnecting the livingarea battery from the 12 V

power supply

Carry out the following work steps in the correct order:

1. Switch off the 12 V main switch on the control and switch panel.

2. Turn off the battery cut-off switch on the Electrobloc.

3. Remove the clamps from the battery poles.

� Before using the battery cut-off switch on the Elektrobloc or before discon-necting the living area battery from the 12 V power supply, the 12 V power supply must be switched off with the 12 V main switch on the control and switch panel!

� For other shutdown tasks, see the instruction manual for the Electrobloc.

Page 21: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 21

Instruction Manual Control and Switch Panel DT 201 B

9 Technical faults, possible causes and remediesIf you are unable to solve a fault using the following tables, please contact our customer service address.

If this is not possible, e.g. if you are abroad, you can have the control and switch panel repaired at a specialist workshop.

Inexpert repairs invalidate the guarantee for the control and switch panel and Schaudt GmbH takes no liability for any resulting damage.

Fault Possible cause Remedy

12 V power supply does not work

12 V main switch turned off Switch on the 12 V main switch

No voltage in living area battery

Living area battery is discharged

Charge the living area bat-tery immediately

� If the living area battery is totally discharged for a lengthy period, it will be irrepara-bly damaged

The battery can be dis-charged by inactive con-sumers such as the frost protection valve in the heater system

Fully charge the living area battery before you shut down the motorhome for any lengthy period

Step alarm even though the step is retracted

Defective sensors or miss-ing D+ signal

Switch off the acoustic warning signal (see the section 5.7) and contact customer service

Page 22: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

22 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

10 Circuit diagram - for specialist workshop only

Fig. 7 Circuit diagram for control and switch panel DT 201 B

X2X1 X4 X5 X6 X9X3 X7 X8

SDT00093

1

1 1

1

1 1

1

1

Plug assignment for thecircuit plan

X1 ELCO 8263 3 x to gas cylinders X2 ELCO 8263 3 x to gas cylinders

1. Negative defroster 1. Negative defroster

2. + Defroster 2. + Defroster

3. Spare gas 1 3. Spare gas 2

X3 Lumberg MSFQ/0 6 x to water tank

X4 Lumberg MSFQ/0 5 x to waste water tank

1. Full 1. Full

2. 3/4 2. 3/4

3. 1/2 3. 1/2

4. 1/4 4. 1/4

5. Base water tank 5. Base waste water tank

6. Not assigned

X5 Lumberg MSFQ/0 12 x to Elec-trobloc BL 3

X6 Lumberg MSFQ/0 7 x to Elec-trobloc BL 9

1. Main switch relay 1 OFF 1. D+ base

2. Main switch relay 1 ON 2. Not assigned

3. Main switch relay 2 OFF 3. Not assigned

4. Main switch relay 2 ON 4. Not assigned

5. Mains indicator 5. Not assigned

6. Shunt consumer 6. Signal solar starter battery

7. Shunt battery 7. Signal solar living area battery

8. Negative living area battery sensor X7 Lumberg MSFQ 2 x (3114) to outside temperature sensor9. Negative lighting

10. + Living area battery sensor 1. Connection 1

11. + Starter battery 2. Connection 2

12. + Lighting

X8 Lumberg MSFQ 3 x to capacity tank rod sensor

X9 RIA plug-in/screw-type termi-nal type 09 4 x to limit switch

1. Signal capacity tank rod sensor 1. Negative

2. Negative capacity tank rod sensor 2. Step

3. + Capacity tank rod sensor 3. Not assigned

4. Not assigned

Page 23: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

SDT-0018-02EN Situation: 18.07.2005 23

Instruction Manual Control and Switch Panel DT 201 B

11 Customer service

Customer service address Schaudt GmbH, Elektrotechnik & ApparatebauDaimlerstraße 588677 MarkdorfGermany

Phone: +49 7544 9577-16

Email: [email protected]

Sending in the device Returning a defective device:

� Use ESD protective bag and well-padded packaging.

� If there is no ESD protective bag, ask Schaudt GmbH for a suitable pro-tective bag.

� Fill in and enclose the fault report, see section 12.

� Send it to the addressee delivered free.

Disposal instruction When the product service life is over, dispose of the device in accordance with the applicable regulations.

Opening hours Mon to ThuFri

8 to 12 a.m., 1 to 4 p.m.8 to 12 a.m.

Page 24: 0 Instruction Manual Control and Switch Panel DT 201 … · 2011-03-08 · 6 Situation: 18.07.2005 SDT-0018-02EN Instruction Manual Control and Switch Panel DT 201 B Spare cylinder

24 Situation: 18.07.2005 SDT-0018-02EN

Instruction Manual Control and Switch Panel DT 201 B

12 Fault reportIn the event of damage, please return the defective device together with the completed fault report.

There is the following defect:(please tick)

Other remarks:

Device type:Type no.:(please enter)

DT 201 B

The following electrical con-sumers do not work:

Malfunction of control and switch panel

TankVoltage/cur-rent

Which dis-play?

Constant fault

Temporary fault/loose con-tact