003-1407-00 - user guide: 630 barrier-free universal

32
User’s Guide Barrier-Free ® Universal Procedures Table For Models: 630 (-001 thru -009) 003-1407-00 Rev. Z (8/15)

Upload: others

Post on 09-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

User’s Guide

Barrier-Free®

Universal Procedures Table

For Models:630 (-001 thru -009)

003-1407-00 Rev. Z (8/15)

© Midmark Corporation 20122

Model / Serial Number:

Date of Purchase:

Midmark Authorized Service Company [name / phone]:

Dealer [name / phone]:

Product Information(The information below is required when calling for service)

Model / Serial Number Location

© Midmark Corporation 20123

Table of Contents

Important InformationSafety Symbols ................................................4Intended Use....................................................5Electrical Requirements ...................................5Electromagnetic Interference ...........................5Disposal of Equipment .....................................5Transportation / Storage Conditions ................5Safety instructions............................................6Hand / Foot Control Connection ......................6Crash Avoidance System .................................6

OperationPower To The Table .........................................7Base Up / Down ...............................................8Back Up / Down ...............................................9Foot Up / Down .............................................10Tilt Up / Down ...............................................11Activation Multiple Functions .........................12Home Function...............................................13Quick Chair® Function ...................................14Programming Table Positions (Programmable Models only)...................................................15One-Touch Positioning (Programmable models only) ...............................................................16Paper Roll ......................................................17Stirrups...........................................................18Treatment Pan ...............................................19Duplex Receptacle (optional) .........................20Headrest Positioning ......................................21Upholstery Heater (optional) ..........................22Rotational Base (optional)..............................23

MaintenanceCleaning .........................................................24Preventative Maintenance .............................24Calling For Service.........................................24

TroubleshootingNo Foot Up Function ......................................25 No Base Down / Back Down or Tilt UP ..........25

Specifications / ComplianceWeights, Dimensions, Electrical Specifications . .......................................................................26Model Identification / Compliance Chart ........27Range of Motion & Dimensions .....................28

Warranty InformationScope of Warranty .........................................30

© Midmark Corporation 20124

CautionIndicates a potentially hazardous situation which could result in injury if not avoided.

Important InformationSafety Symbols

Equipment AlertIndicates a potentially hazardous situation which could result in equipment damage if not avoided.

Note Amplifiesaprocedure,practice,orcondition.

Consult User Guide for important information.

Protective earth ground

Duty Cycle (motor run time):30secondsON,5minutesOFF

Fuseratingspecification

Protected against dripping water

TypeB,AppliedPart

Proper Shipping Orientation Maximum stacking height(palletted units)

Fragile

Keep dry

6.3A 250V TYPE T

Emergency Stop

This product has been evaluated with respect to electrical shock, fire & mechanical hazards only, in accordance with UL60601-1 and CAN/CSA C22.2 NO. 601.1.

Patient weight limit

Pan must be fully retracted to enable Foot Up function.

204 kg 450 lbs

CLASSIFIED TO: UL STD. 60601-1

42185

CERTIFIED TO: CAN/CSA STD. C22.2 NO. 601.1

IPX1

WArNINg Indicates a potentially hazardous situation which could result in serious injury.

© Midmark Corporation 20125

Intended UseThis product is intended to be used as a chair / table to provide positioning and support of patients during generalexaminationsandproceduresconductedbyqualifiedmedicalprofessionals.

Electrical requirements

Electromagnetic InterferenceThis Midmark table is designed and built to minimize electromagnetic interference with other devices. However,ifinterferenceisnoticedbetweenanotherdeviceandthistable: • Removeinterferingdevicefromroom • Plugtableintoanisolatedcircuit • Increaseseparationbetweentableandinterferingdevice • ContactMidmarkifinterferencepersists

Disposal of EquipmentAttheendofproductlife,thetable,accessories,andotherconsumablegoodsmaybecomecontaminatedfromnormaluse.Consultlocalcodesandordinancesforproperdisposalofequipment,accessoriesandother consumable goods.

Caution When using high frequency surgical devices or endocardial catheters:

• Use non-conductive material to insulate patient from metal portions of the table. • Consult operating instructions for the device before using in conjunction with drawer

or upholstery heater.

Failure to comply may result in electric shock or burns to patient.

Transportation / Storage ConditionsAmbient Temperature Range ................................................................. +41°F to 100°F (+5°C to +38°C)Relative Humidity......................................................................................10% to 90% (non-condensing)Atmospheric Pressure ............................................................ 500hPa to 1060hPa (0.49atm to 1.05atm)

© Midmark Corporation 20126

Caution Be sure that all personnel and equipment are clear of the table before activating any function. Failure to do so could result in personal injury.

Safety Instructions

Hand / Foot Control Connection

There are two hand / foot control cord inlets. One is located on the base column at the foot end of the table, and one is located on the PC board cover at the head end. These cord inlets are interchangeable.

Crash Avoidance System

The Crash Avoidance System prevents the table from colliding with the floor. If the system detects that the headrest mechanism is approximately two inches from the floor, it will sound several audible “beeps” and disable the following functions: Base Down, Back Down, and Tilt Up.

Equipment Alert Never plug hand/foot

control into any other outlets. Doing so may damage equipment.

MA642902i

To connect hand / foot control cord...A) Slide narrow portion of cord connector into bracket. B) Connect cord to inlet (see Note). C) Tighten locking ring.

Note: The cord connector is “keyed” and must be oriented properly to connect.

rear Cord Inlet Locking ring

Tilt Up

Back Down

Base Down

Front Cord Inlet

clearance: ≤ 2 in. (5 cm)

© Midmark Corporation 20127

115V

OperationPower To The Table

If the table has no power... All functions will be inoperable. Before calling for service...A) Check power cord connections. B) Check / reset facility circuit breaker. C) Check / replace table fuse(s).

To replace fuses... [Refer to Specifications section for correct fuse size & ratings]A) Open the fuse holder cover. B) Remove fuse holder & faulty fuse(s). C) Install new fuse(s), then replace fuse holder. Attention: Voltage setting that shows thru window of fuse

holder cover must match facility supply voltage.

Before replacing fuses... Disconnect power cord from table.

Equipment Alert Incorrect voltage setting will result

in damage to the table.

If Power Indicator Light is...ON: Table has power. OFF: No power to table.

© Midmark Corporation 20128

Base Up / Down

To move the Base UP or DOWN...Press and hold the appropriate button.

Movement stops when...Up / Down button is released.Maximum / minimum position is reached.Stop button is pressed.

Min. 19 in.

(48.2 cm)

Max. 40 in.

(101.6 cm)

Models w/Rotational BaseMax.

43.5 in. (110.5 cm)

Min. 22.5 in. (57.1 cm)

Down

Stop

Up

Up

Down

© Midmark Corporation 20129

Back Up / Down

Min. 0° ±0.5°

Max. 85° ±3°

To move the Back section UP or DOWN...Press and hold the appropriate button.

Movement stops when...Maximum / minimum position is reached.Up / Down button is released. Stop button is pressed.

DownUp

Up

Down

Stop

© Midmark Corporation 201210

Foot Up / DownAttention!The Foot Up function is disabled when the treatment pan is pulled out. (You will hear several “beeps” when Foot Up is activated with the pan pulled out.)

To resume Foot Up operation: Push the pan all the way in. Press Foot Up button.

Max. 0° ±0.5°

Min. 89° ±1°

To move the Foot section UP or DOWN...Press and hold the appropriate button.

Movement stops when...Maximum / minimum position is reached.Up / Down button is released. Stop button is pressed.

DownUp

Up

Down

Stop

© Midmark Corporation 201211

Min. 0° ±0.5°

Max. 30° ±2°

Tilt Up / Down

To Tilt the seat section UP or DOWN...Press and hold the appropriate button.

Movement stops when...Maximum / minimum position is reached.Up / Down button is released. Stop button is pressed.

DownUp

Up

Down

Stop

© Midmark Corporation 201212

Activating Multiple FunctionsThe BASE / BACK / TILT / FOOT functions may be activated at the same time.

Example: Base Up / Back Down

To activate multiple functions ...Simultaneously press & hold the desired buttons. (ex. Base Up & Back Down)

Back Down

Back Down

Base Up

Base Up

© Midmark Corporation 201213

23 in (58.4 cm)

19 in (48.2 cm)

Home FunctionThe Home function automatically lowers the table base so that your patient may get on or off of the table.

To lower the base to 23 in. (58.4 cm)...Press, then immediately release the Home button.

To lower the base to 19 in. (48.2 cm)...Press and hold the Home button until you hear a single “beep”.

Home Home

Stop

Movement stops when...“Home” position is reached.Stop button is pressed.

© Midmark Corporation 201214

Quick Chair® Function(w/ Foot Control only)

The Quick Chair® function activates the Base Down, Tilt Down, Foot Down, & Back Up functions at the same time.

To activate the Quick Chair® function....Press and hold the Quick Chair® button.

Stop

Quick Chair®

Button

Movement stops when...“Chair” position is reached.

Quick Chair® button is released. Stop button is pressed.

© Midmark Corporation 201215

Programming Table Positions (Programmable Models only)

The Programming feature allows you to easily recall frequently used table positions.

To program a table position...A) Move the table to desired position. B) Press the Program button. (you will hear a single “beep”) C) Press the desired Position button (1, 2, 3, or 4).

(three “beeps”) Tip: You must press the desired Position button within 5 seconds

of pressing the Program button.

To recall a programmed position...Press and hold the desired Position button (1, 2, 3, or 4)*. Tip: The Position buttons (1, 2, 3, 4) can be changed to

function as “press & release”. Refer to: One-Touch Positioning for procedure to enable.

Stop

Stop

Program

Program

Position Button

Position Buttons

Movement stops when...Programmed position is reached.Position button is released. Stop button is pressed.

© Midmark Corporation 201216

One-Touch Positioning (Programmable Models only) From serial number V421340 and up

During normal operating mode, the Position buttons must be pressed & held until the programmed position is reached. When the One-Touch Positioning feature is activated, the Position buttons function as “press & release”.

To enable (or disable) the One-Touch Positioning feature...Press & hold the Stop & Program buttons simultaneously. (after five seconds, you will hear three “beeps” if successful)

To recall a programmed position...Press the desired Position button (1, 2, 3, 4) for two seconds. Tip: After you hear a single “beep”, you may release the button &

the chair will continue to move to the programmed position.

Stop

Stop

Program

Program

Position Button

Position Buttons

Movement stops when...Programmed position is reached. Stop button* is pressed. (* or any hand / foot control button)

© Midmark Corporation 201217

Paper rollPaper Roll Size (max.)....................................................... 18 in. long x 3.5 in. diameter (45.7 cm x 8.9 cm)

To install the paper roll...A) Pivot paper roll cover back to open. B) Install paper roll, then pull paper over table. C) Pivot paper roll cover forward to close.

© Midmark Corporation 201218

Stirrups

To position the stirrups...A) Pull the stirrup out, then unfold. B) Lift the stirrup slightly, then move it left or right as desired. C) Release stirrup to lock in position.

Caution Never use stirrups to lift table. Be sure the stirrups are locked in place before using.

The stirrups will not support the patient’s entire weight / excessive force.

© Midmark Corporation 201219

Treatment PanAttention!The Foot Up function is disabled when the treatment pan is pulled out. (You will hear several “beeps” if Foot Up is activated with the pan pulled out).

To resume Foot Up operation: Push the pan all the way in. Press Foot Up button.

To access the treatment pan...A) Lower the foot section.B) Pull the treatment pan slide out.

© Midmark Corporation 201220

Duplex receptacle (optional - not available on 230 volt models)

The duplex receptacle provides power for accessories used during medical procedures. Power to the receptacle will be interrupted if the maximum load is exceeded. Maximum Load [both receptacles combined] .................115 VAC, 3 amps, 50/60 Hz

Equipment Alert Exceeding the maximum load for the receptacle may result in blown fuses. If this occurs, all table functions will be disabled until fuses are replaced. [Fuse replacement procedure is shown on the Power To The Table page.]

© Midmark Corporation 201221

B

C

A

Headrest Positioning

[For clarity, the upholstery is not shown]

To adjust the headrest at pivot points A and/or B...A) Pull upper handle outward to release. B) Move pivot point(s) to desired position. C) Push upper handle inward to lock in place.

To adjust the headrest at pivot point C...A) Pull lower handle outward to release. B) Move pivot point to desired position. C) Push lower handle inward to lock in place.

CautionBe sure headrest is locked securely in position before use.

NoteThe handle tension is adjustable. Contact your service provider if an adjustment is required.

© Midmark Corporation 201222

Equipment AlertIf the back or seat section of the heated upholstery is punctured, it must be repaired or replaced to ensure proper operation.

Upholstery Heater (optional)

The upholstery heater warms the seat and back sections of the upholstered top.

To turn upholstery heater ON / OFF...Press and release the Upholstery Heater Button on the hand control. Note: The upholstery heater will... • reach operating temperature in approx. 15 - 20 minutes. • automatically shut off after 8 hours.

If Upholstery Heater Light is...ON: Heater is ON OFF: Heater is OFF

Upholstery Heater Button

Upholstery Heater Light (amber)

Power Indicator Light (green)

© Midmark Corporation 201223

Brake Pedal

rotational Base (optional)

To rotate the table base...A) Press and release the brake pedal. B) Rotate the table to desired position.

To lock in position...A) Press and release the brake pedal.

Note: The base will automatically lock in position after two minutes.

350°

© Midmark Corporation 201224

MaintenanceCleaningUpholstery Washyourupholsteryweeklywithamildliquidsoapandwatermixture,rinsewithclearwater and dry completely to remove disinfection cleaner build-up. Disinfect your upholstery with a solution of standard bleach and water mixed 1 in 10 (10%) or chlorine based cleaners. Follow this with a clear water rinse and thorough drying of material. See current CDC Guideline for Disinfection & Sterilization in Healthcare Facilities. Tominimizedamagecausedbydisinfectantcleanerresiduebuild-up,donotallowdisinfectantstopoolontheupholsterysurface.Oncetheapprovedcontacttimehasbeenobtained,removeanddryexcessliquidremaining on the surface. Detailed care and maintain instructions are available in your user guide located on the CD that came with your table or by referring to Upholstery Care and Maintenance. Painted Metal / Plastic Surfaces Cleanthepaintedmetalandplasticsurfacesweeklyusingacleansoftcloth,andmildcleaner.Periodic applicationsofcommonfurniturewaxwilleasecleaning,andmaintainthefinishedlusterofthesurfaces.

Preventative MaintenancePeriodically inspect the following areas: •Powercordshouldbefreeofcutsorothervisibledamage. •Allfastenersshouldbepresentandtightenedsecurely. •Allmechanicalfunctionsshouldoperateproperly. Haveaqualifiedservicetechnicianinspectyourtableeverysixmonths.

Calling For Service [Product serial number is required]

Ifserviceisrequired,contactyourMidmarkdealerortolocateyournearestserviceprovider,logonto: http://www.midmark.com To contact Midmark directly: 1-800-MIDMARK (1-800-643-6275) 8:00 am until 5:00 pm. Monday through Friday (EST) [excluding standard U.S. holidays]

Equipment Alert The upholstery is resistant to most medicinal-type stains, but may be damaged by solvents and dyes. Immediately remove any fluids spilled on the upholstery.

© Midmark Corporation 201225

TroubleshootingNo Foot Up Function

No Base Down, Back Down, and/or Tilt Up Functions*

Function Status Problem Correction

Foot Up No movement (“beeps”) Push treatment pan in.

All other functions OK -

Function Status Problem Correction

Base Down No movement (“beeps”) ActivateBackUpandTiltDown,then try Base Down again.

Back Down No movement (“beeps”) ActivateBaseUpandTiltDown,then try Back Down again.

Tilt Up No movement (“beeps”) ActivateBaseUpandBackUp,then try Tilt Up again.

All other functions OK -

* The Crash Avoidance System disables the Base Down, Back Down, and Tilt Up functions to prevent the headrest from colliding with the floor. For more information, refer to the Crash Avoidance System section.

© Midmark Corporation 201226

Patient Weight (maximum): 450 lbs (204.1 kg)Paper Roll (maximum size): 18 in. long x 3.5 in. diameter

(45.7 x 8.9 cm)Range of Motion & Dimensions: [See Range of Motion & Dimensions page]Weight of Table: 630 (w/standard base) w/packaging & skid 630 (w/rotational base) w/packaging & skid

455 lbs (206.4 kg) 510 lbs (231.3 kg) 540 lbs (244.9 kg) 600 lbs (271.1 kg)

Power Cord: 8 ft. (243.8 cm) longElectrical Requirements: [See Model I.D. / Compliance Charts]Foot / Hand Control Voltage: 10VAC,SELV(SafetyExtraLowVoltage)Duplex Receptacle (optional) maximum load: 115VAC,3A,50/60HzFuses: Located at power cord inlet: F1 & F2

6.3A,250V,TypeT,5x20mm

Duty Cycle (motor run time):

Intermittent Operation [30 seconds ON / 5 minutes OFF]

Classifications: Class1,TypeBAppliedPart

Protection against ingress of fluids: Foot Control only:

Ordinary Equipment IPX1

Regulatory Compliance: [See Compliance Charts]

SpecificationsWeights, Dimensions, Electrical Specifications

WArNINg Equipment not suitable for use in the presence of a flammable anesthetic mixture.

© Midmark Corporation 201227

Model Identification / Compliance Chart

Mod

elD

escr

iptio

nSe

rial

Num

ber

Prefi

x

Com

plie

s To

:El

ectr

ical

Rat

ings

:

UL

6060

1-1

CA

N/C

SA

22.2

, #6

01.1

-M90

IEC

60

601-

1

EN

6060

1-1-

2 (E

MC

)

VAC

+/

-10%

Am

psC

ycle

s (H

z)

630-

001

Mid

mar

k U

nive

rsal

Pro

c. T

able

(N

on-P

rogr

amm

able

)V

XX

XX

Con

figur

able

50 /

6011

523

07 3.5

630-

002

Mid

mar

k U

nive

rsal

Pro

c. T

able

(P

rogr

amm

able

)V

XX

XX

Con

figur

able

50 /

6011

523

07 3.5

630-

003

Mid

mar

k U

nive

rsal

Pro

c. T

able

(N

on-P

rogr

amm

able

) w

/ Rec

epta

cle

VX

XX

X11

510

50 /

60

630-

004

Mid

mar

k U

nive

rsal

Pro

c. T

able

(P

rogr

amm

able

) w

/ Rec

epta

cle

VX

XX

X11

510

50 /

60

630-

005

Mid

mar

k U

nive

rsal

Pro

c. T

able

(N

on-P

rogr

amm

able

) w

/ Rot

atio

nal B

ase

VX

XX

XC

onfig

urab

le50

/ 60

115

230

7.5

3.8

630-

006

Mid

mar

k U

nive

rsal

Pro

c. T

able

(P

rogr

amm

able

) w

/ Rot

atio

nal B

ase

VX

XX

XC

onfig

urab

le50

/ 60

115

230

7.5

3.8

630-

007

Mid

mar

k U

nive

rsal

Pro

c. T

able

(P

rogr

amm

able

) w

/ Hea

ted

Uph

olst

ery

VX

XX

X11

57

50 /

60

© Midmark Corporation 201228

range of Motion & Dimensions

Max. 0° ±0.5°

Min. 89° ±1°

Min. 0° ±0.5°

Max. 85° ±3°

Min. 0° ±0.5°

Max. 30° ±2°

19 in. (48.2 cm)

Min. * see below

* Min. w/ standard base: 19 in. (48.2 cm) w/ rotational base: 22.5 in. (57.1 cm)

Max. Standard base: 40 in. (101.6 cm) Rotational base: 43.5 in. (110.5 cm)

© Midmark Corporation 201229

range of Motion & Dimensions - (continued)

28.3 in. (71.8 cm)

(Foot Up)

11 in. (28 cm)

72 in. (182.8 cm)

62 in. (157.4 cm)

(Foot Dow

n)

Optional Power Cord 3 ft.

(91 cm)

Standard Power Cord 8 ft.

(2.4 m)

Standard Base (shown) 18 in.

(46 cm)

(Standard Base Casting shown)

rotational Base 27 in.

(68.5 cm)

© Midmark Corporation 201230

Warranty InformationSCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants to the original retail purchaser that it will repair or replace components of the domestic and international medical products manufactured by Midmark (except for components not warranted under “Exclusions”) that are defective in material or workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement,atMidmark’soption,oftheapplicablecomponents.ThislimitedwarrantyshallonlyapplytodefectsthatarereportedtoMidmarkwithintheapplicablewarrantyperiodandwhich,uponexaminationbyMidmark,provetobedefective.Thiswarrantyextendsonlytothefirstretailpurchas-er of a product and is not transferable or assignable.

APPLICABLE WARRANTY PERIODTheapplicablewarrantyperiod,measuredfromthedateofdeliverytotheoriginaluser,shallbeone(1) year for all warranted products and components.

OBTAINING WARRANTY SERVICEWarranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark.com; by phone at 1-800-MIDMARK; by facsimile at 1-800-365-8631;orbymailtoMidmarkCorporation,60VistaDrive,Versailles,Ohio45380.

It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its au-thorizeddealersforwarrantyservice,whichdeliveryshallbeatretailpurchaser’sexpense.Itisalsothe retail purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warrantyregistrationinformationwithinthirty(30)daysafterpurchaseinordertoobtainthebenefitsof this warranty.

EXCLUSIONSThiswarrantydoesnotcover,andMidmarkshallnotbeliable,forthefollowing:

(1)defects,damageorotherconditionscaused,inwholeorinpart,bymisuse,abuse,negligence,alteration,accident,freightdamage,tamperingorfailuretoseekandobtainrepairorreplacementina timely manner;(2)productswhicharenotinstalled,used,andproperlycleanedandmaintainedasrequiredintheMidmark “Installation” and/or “Installation/Operation Manual” for the applicable product;(3) products considered to be of a consumable nature;(4) accessories or parts not manufactured by Midmark;(5)chargesbyanyoneforadjustments,repairs,replacementparts,installationorotherworkperformed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark;(6) costs and expenses of routine maintenance and cleaning; and(7) representations and warranties made by any person or entity other than Midmark.

© Midmark Corporation 201231

Warranty Information (continued)EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER:MIDMARK’S ONLY OBLIGATION UNDER THIS WARRANTY IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT,SPECIAL,INDIRECT,INCIDENTAL,EXEMPLARYORCONSEQUENTIALDAMAGESORDELAYS,INCLUDING,BUTNOTLIMITEDTO,DAMAGESFORLOSSOFPROFITSORINCOME,LOSSOFUSE,DOWNTIME,COVERANDEMPLOYEEORINDEPENDENTCONTRACTORWAGES,PAYMENTSANDBENEFITS.

NO AUTHORIZATIONNopersonorfirmisauthorizedtocreateorapproveforMidmarkanyotherobligationorliabilityinconnection with the products.

WARRANTY DISCLAIMERTHIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES,EXPRESSORIMPLIED.MIDMARKMAKESNOIMPLIEDWARRANTIESOFANYKIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.

STATUTE OF LIMITATIONSNoactionmaybebroughtagainstMidmarkforbreachofthislimitedwarranty,animpliedwarranty,ifany,orforanyotherclaimarisingoutoforrelatingtotheproducts,morethanninety(90)daysfollowing expiration of the limited warranty period.

Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles,OH45380-0286 Phone: 937-526-3662 Fax: 937-526-5542 www.midmark.com

© Midmark Corporation 2008

Language of origin: English