  • 8/14/2019 01 PDI analizer.pdf

    1/3

    Parts Per Million Water Analyzers

    Phase Dynamics, Inc.

    1251 Columbia Drive

    Richardson, TX 75081 USAE-Mail [email protected]

    Tel: 972-680-1550

    Fax: 972-680-3262

    Phase DynamicsTechnology for Precision

    Measurements

    Phase Dynamics, I nc.PDI_PPM_0104 Page 1 Phase Dynamics, Inc. 2004

    Certifications Available

    CSA, FM, CE, EEX

    Temperature Probe Included

    Self Calibrating Current Loop

    New Generation Sensor and

    Electronics

    Oil Field Proven Rugged Design

    ModBus RTU & 4-20 mA

    24 VDC Power

    Multi-drop up to 32 Systems

    Operator Interface System

    Available

    Typically used for measurement inliquid propane, propylene and otherpipelined products to determine

    when incoming product exceeds

    required moisture levels. Can alsobe used in a gas pipeline todetermine water content. Flexibilityfor the user is provided through the

    use of stainless steel tubing toconnect anywhere in the processwhere a minor pressure drop can beobtained.

    Phase Dynamics Analyzers offerthe most reliable, maintenance freemeasurement possible. Phase

    Dynamics utilizes the patented,

    Oscillator Load Pull microwavetechnology which provides thereproducibility and accuracyrequired for these applications.

    This technology coupled with theCompany's patented use of aluminum oxide beads provides theprocess measurement to ppm levels.

    ll functions of the analyzers areccessed through use of an optional

    Operator Interface System (OIS).

    o external electronics is required

    fter initial set up with the OIS.Output is MODBUS-RTU or asimple 4-20 mA current loop. Fulldigital access to the information is

    standard. Measurement Sectionlectronics is explosion proof.

    Temperature averaging for pipelinebatches is available.

    10 ppm to 5,000 ppm Water

    1/2" Flow-Through TubingConnections

    High Pressure - to 3,000 psi

    On-Line Measurement

    Recovers from 100% WaterWithout Damage to Sensor

    Responds Quickly to Increasing

    Water Content

  • 8/14/2019 01 PDI analizer.pdf

    2/3

    Technology for Precision Measurements

    PDI_PPM_0104 Page 2

    PPM Water Analyzer Operational Specifications

    PARAMETER Range Comments

    RANGE 10 ppm to 5,000

    ppmResponse Time is Determined by

    Flow Rate

    ACCURACY +/- 20 ppm

    REPEATABILITY +/- 10 ppm

    RESOLUTION 5 ppm

    FLUID TEMPERATURE 60 - 160F

    HIGH TEMP. VERSION 60 - 220F

    RESPONSE TIME(Minutes)

    10 minutes To Achieve 80% of Final Value

    System Specifications

    General:

    Power Requirements:

    18-28 VDC120 VAC with CIS (Optional)

    25 Watts Typical, 50 Watts Maximum

    Outputs:Analog: 4-20ma, 12 bit D-to-A Conversion

    Digital: RS-485 Modbus RTU

    Fluid Temperature Compensation:

    Automatic with Built-in RTD Temperature ProbeTemperature Averaging Optional

    Ambient Temperature Ranges:

    Measurement Section: -40 to +120F

    Electronics: +32 to +120 F; Sun Shade Recommended

    Fluid Temperatures:

    Standard 60to 160F

    Optional 60to 220F

    Optional 100 to 400 F

    Optional 100 to 600 FLower Temperatures Optional

    Operator Interface System Electronics &

    Enclosures (Optional):

    Standard Explosion Proof Enclosure:

    17.4 H x 14.0 W x 9.9 D inches; 59 lbs., NEMA 4,7 & 9; Class1, Div. 1, Groups C&D; EEx d IIB T5 89C - IP66 (Optional)

    Rain and Dust Tight Fiberglass Enclosure:

    16.3 H x 10.5 W x 7.9 D inches; 17 lbs., NEMA 4

    LCD Display:

    Bit Mapped

    Alpha Numeric plus Graphics

    Measurement Section:

    Pressure Ratings:

    Flange Sizes up to ANSI 1,500; Swagelok Fittings standard;Others Optional

    Construction:

    316/316L Standard; Other Materials Available; Designed andFabricated per ASME B31.3 & ASME IX; Full Material

    Certifications Optional

    Process Connections:3/8 Swagelok Fittings

    Cable between Operator Interface System (CIS) and Measurement

    Section:

    Dedicated 4 Conductor 4,000 feet Maximum Length between

    Electronics and Measurement Section

    Certifications:

    Class 1, Div. 1, Groups C&D;

    EEx d IIB T5 89C - IP66 (Optional)

    Optional Certifications:

    GOST, CSA, FM, CE & EEx

    Phase Dynamics, Inc. 2004

  • 8/14/2019 01 PDI analizer.pdf

    3/3

    Measurement Section Physical Drawing

    Technology for Precision Measurements

    PDI_PPM_0104 Page 3 Phase Dynamics, Inc. 2004

    Specifications Subject to Change