EM DESCRIPTION
High Voltage Cables
1 Manufacturer :
Name .................................................……
Country .......................................................
Type designation ......................................
2 Applicable standard ............................................
3 Rated voltage .........................................…... KV
4 Max. continuous current carring capacity at installed site
condition ..........…………………… A
5 Conductor material ........................................(Cu/AL)
6 Type of conductor ………………(stranded/other type)
7 Number of cores ……………………………….
8 Cross section of .......................................... mm
9 Nominal diameter………………………………….mm
10 Thickness of conductor screen(semi-conductor)(mm)
11 Core insulation material and thickness..................
12 Thickness of insulation screen(semi-conductor)(mm)
13 Material of shield ...................................................
14 Cross section of shield ….............................. mm
15 Water blocking layer material ………………..
16 Armour bedding material / thickness ………….(mm)
17 Whether armour wire is provided …………(yes/no)
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
8/10/2019 03- CABLE (Guaranty).pdf
http://slidepdf.com/reader/full/03-cable-guarantypdf 2/7
IT
EM DESCRIPTION
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
18 Diameter of armour wire/Tape…………………………..
19 Material of armour wire/Tape ………………………….
20 Material and color of outer sheath .............................
21 High voltage test ………………………….. Kv (r.m.s)
22 Basic insulation level ………………………Kv (peak)
23 Short circuit level
Symmetrical current ………..…………..KA(r.m.s)/sec
Maximum dynamic current …………………KA(peak)
Initial/ final temperature …………………………
24 Short circuit withstand current/time of armour
………KA(r.m.s)/sec
25 Minimum radius of bend round…….(in air/ground)
26 Max. DC resistance at 20!c ……("/km)
27 Max. AC resistance at 90!c ……("/km)
28 Approx. weight of cable ……………..kg/m
Medium Voltage Cables
1 Manufacturer :
Name .................................................……
Country .......................................................
Type designation ......................................
2 Applicable standard ............................................
3 Rated voltage .........................................…... KV
4 Max. continuous current carring capacity at installed site
condition for power transformer feeders
..........…………………………………. A
8/10/2019 03- CABLE (Guaranty).pdf
http://slidepdf.com/reader/full/03-cable-guarantypdf 4/7
IT
EM DESCRIPTION
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
21 High voltage test ………………………….. Kv (r.m.s)
22 Basic insulation level ………………………Kv (peak)
23 Short circuit level
Symmetrical current ………..…………..KA(r.m.s)/sec
Maximum dynamic current …………………KA(peak)
24 Short circuit withstand current/time of armour
………KA(r.m.s)/sec
25 Minimum radius of bend round…….(in air/ground)
26 Conductor DC resistance at 20!c ……("/km)
Low Voltage Power Cables
1 Manufacturer :
Name ...............................................................
Country ...........................................................
Type designation ............................................
2 Applicable standard .................................................
3 Rated voltage ............................................. KVrms
4 Number of cores / size…………………………
5 Conductor material ...........................................(Cu/Al)
6 Type of conductor ………………(stranded/other type)
7 Min thickness & material of insulation ..............(mm)
8 Type and thickness of inner sheath material …..(mm)
9 Whether shield is provided ………… (yes/no)
10 Type and Material of armour ........ (wire/tape&steel/Al)
8/10/2019 03- CABLE (Guaranty).pdf
http://slidepdf.com/reader/full/03-cable-guarantypdf 5/7
IT
EM DESCRIPTION
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
11 Type and thickness of outer sheath material ……(mm)
12 High voltage test …………………………………KV
13 Short circuit withsand current/time of conductor KA/Sec
Control Cables
1 Manufacturer :
Name ..............................................................
Country ...........................................................
Type designation ...........................................
2 Applicable standard ................................................
3 Rated voltage ................................................... KV
4 Conductor material ................................................
5 Diameter of each strand ................................ mm
6 Number and cross section of wires in each
cable ........................................................................
For CT cable
For CVT cable
For control cable
7 Insulation material ..................................................
8 Material and thickness of inner sheath ………….(mm)
9 Material and thickness of shield ..........................(mm)
10 Material and thickness of bedding for armour …(mm)
11 Material and thickness of armour.....................(mm)
12 Material and thickness of outer sheath ………….(mm)
8/10/2019 03- CABLE (Guaranty).pdf
http://slidepdf.com/reader/full/03-cable-guarantypdf 6/7
IT
EM DESCRIPTION
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
13 Short circuit withstand current/time of conductors..KA/Sec
E Medium Voltage Cable Sealing ends
1 Manufacturer :
Name .............................................................. Country ............................................................
Type designation ...........................................
2 Rated voltage ..........................................................
3 Insulation material ..................................................
4 Overall length .................................................. mm
5 Heat shrinkable ......................................... (yes/no)
6 Type of material ....................................................
7 Color ........................................................................
8 Creepage distance for outdoor cable sealing
ends ................................................................... mm
9 Creepage distance for indoor cable sealing
ends ................................................................ mm
10 Non tracking ............................................. (yes/no)
F High Voltage Cable Sealing ends
1 Manufacturer :
Name ..............................................................
Country ............................................................
Type designation ...........................................
8/10/2019 03- CABLE (Guaranty).pdf
http://slidepdf.com/reader/full/03-cable-guarantypdf 7/7
IT
EM DESCRIPTION
TABLE OF TECHNICAL GUARANTEES
CABLE SYSTEM
GUARANTEED
PARTICULAR
2 Rated voltage ..........................................................
3 Insulation material ..................................................
4 Creepage distance ………………………………..mm
5 Conductor size ……………………………………..mm^2
6 Color ……………………………………………………
7 Type of supporting insulator
8 Overall length .................................................. mm
Cable Glands
1 Cable glands :
Manufacturer ...................................................
Material .........................................................
Type designation ..........................................
H Cable Trays
Manufacturer :
Name ..............................................................
Country ...........................................................
Type designation ...........................................
Material ................................................... ...............
Galvanized thickness ..............................................