    FlexiPacket Hub 800

    R2.5

    IDU and Accessories Order CodesReference

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    Nokia Siemens Networks is continually str iving to reduce the adverse environmental effects of

    its products and services. We would like to encourage you as our customers and users to join

    us in working towards a cleaner, safer environment. Please recycle product packaging and

    follow the recommendations for power use and proper disposal of our products and their

    components.

    If you should have questions regarding our Environmental Policy or any of the environmental

    services we offer, please contact us at Nokia Siemens Networks for any additional information.

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    2/21

    2 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes Reference

    The information in this document is subject to change without notice and describes only the

    product defined in the introduction of this documentation. This documentation is intended for the

    use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

    in any form or means without the prior written permission of Nokia Siemens Networks. The

    documentation has been prepared to be used by professional and properly trained personnel,

    and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

    customer comments as part of the process of continuous development and improvement of the

    documentation.

    The information or statements given in this documentation concerning the suitability, capacity,

    or performance of the mentioned hardware or software products are given "as is" and all liability

    arising in connection with such hardware or software products shall be defined conclusively and

    finally in a separate agreement between Nokia Siemens Networks and the customer. However,

    Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

    contained in the document are adequate and free of material errors and omissions. Nokia

    Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

    may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

    EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-

    TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,

    INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT

    LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS

    OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR

    THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and

    other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

    of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2013. All rights reserved.

    f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources

    of danger.

    Only trained and qualified personnel may install, operate, maintain or otherwise handle

    this product and only after having carefully read the safety information applicable to this

    product.

    The safety information is provided in the Safety Information section in the Legal, Safety

    and Environmental Information part of this document or documentation set.

    The same text in German:

    f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder

    andere Gefahrenquellen ausgehen.

    Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch

    geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-

    anforderungen erfolgen.

    Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal,

    Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-

    satzes.

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    3/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    3

    IDU and Accessories Order Codes Reference

    Table of ContentsThis document has 21 pages.

    1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1.2 Structure of this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1.3 History of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1.4 Symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1.5 Waste electrical and electronic equipment (WEEE) . . . . . . . . . . . . . . . . 9

    1.6 RoHS compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    1.7 CE compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    1.8 MEF compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    2 FPH800 mainboard and main hardware order codes . . . . . . . . . . . . . . 12

    2.1 Mainboard order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.2 Plug-in cards order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    2.3 SFP module order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    2.3.1 SFP GE module order codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    2.3.2 SFP STM-1/4 module order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    2.4 Patch panels and cables order codes . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    2.5 Dual-IDU accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    3 FPH800 mounting and connection accessories ordering codes . . . . . . 16

    3.1 Mounting kits order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    3.2 Connection accessories for Ethernet copper interfaces . . . . . . . . . . . . 16

    3.3 Connection accessories for Ethernet optical interfaces. . . . . . . . . . . . . 173.4 Connection accessories for STM-1/4 optical interfaces. . . . . . . . . . . . . 17

    3.5 Connection accessories for FlexBus interfaces. . . . . . . . . . . . . . . . . . . 18

    3.6 Connection accessories for E1 interfaces . . . . . . . . . . . . . . . . . . . . . . . 18

    4 Software and licenses order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    4.1 Software order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    4.2 licenses order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    4.3 In-field software upgrading kit order codes . . . . . . . . . . . . . . . . . . . . . . 20

    5 FOC order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    4/21

    4 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes Reference

    List of FiguresFigure 1 WEEE label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Figure 2 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    Figure 3 MEF certified compliant logo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    5/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    5

    IDU and Accessories Order Codes Reference

    List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    Table 2 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    Table 3 List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Table 4 Mainboard and main options order codes . . . . . . . . . . . . . . . . . . . . . . . 12

    Table 5 Plug-in cards order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Table 6 SFP GE module order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Table 7 SFP STM-1/4 module order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Table 8 Patch Panels order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Table 9 Cables order codes for 16 X E1/T1 RJ48c patch panel . . . . . . . . . . . . 14

    Table 10 Dual-IDU accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Table 11 Mounting kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Table 12 Connection Accessories for Ethernet copper interfaces . . . . . . . . . . . . 16

    Table 13 Connection Accessories for Ethernet optical interfaces . . . . . . . . . . . . 17Table 14 Connection Accessories for Flexbus interfaces . . . . . . . . . . . . . . . . . . 18

    Table 15 Connection Accessories for 16 x E1 interface . . . . . . . . . . . . . . . . . . . 18

    Table 16 Software order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Table 17 Licenses order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Table 18 In-field software upgrading kit order code . . . . . . . . . . . . . . . . . . . . . . 20

    Table 19 FOC order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    6/21

    6 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes Reference

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    7/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    7

    IDU and Accessories Order Codes Reference Preface

    1 PrefaceThis document provides the order codes for Nokia Siemens Networks FlexiPacket Hub

    800 (FPH800 in short), software release R2.5. FPH800 is an Indoor Unit (IDU) of Nokia

    Siemens Networks FlexiPacket Microwave family.

    1.1 Intended audience

    This document is intended for the radio network planners and the technicians in charge

    of operating and maintaining the FlexiPacket Hub 800.

    1.2 Structure of this document

    The document is divided into the following main chapters:

    1.3 History of changes

    1.4 Symbols and conventions

    The following symbols and mark-up conventions are used in this document:

    Chapter Title Subject

    Chapter 1 Preface Providing an introduction and overview

    of code reference.

    Chapter 2 FPH800 mainboard and main

    hardware order codes

    Providing order codes of FPH800 main-

    board and its main hardware.

    Chapter 3 FPH800 mounting and con-

    nection accessories ordering

    codes

    Providing ordering codes for mounting

    kits and connection accessories.

    Chapter 4 Software and licenses order

    codess

    Providing the order coeds of the

    software release and licenses.

    Chapter 5 FOC order codes Providing FOC order codes for refer-

    ence.

    Table 1 Structure of this document

    Issue Issue date Remarks

    1 May 2013 1st version

    Table 2 History of changes

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    8/21

    8 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferencePreface

    Representation Meaning

    fDANGER!

    fWARNING!

    fCAUTION!

    A safety message indicates a dangerous situation where

    personal injury is possible.

    The keywords denote hazard levels with the following meaning:

    DANGER!- Indicates a hazardous situation which, if not

    avoided, will result in death or serious (irreversible) personal

    injury.

    WARNING!- Indicates a hazardous situation which, if not

    avoided, could result in death or serious (irreversible) personal

    injury.

    CAUTION! - Indicates a hazardous situation which, if not

    avoided, may result in minor or moderate (reversible) personal

    injury.

    wNOTICE: A property damage message indicates a hazard that may resultin equipment damage, data loss, traffic interruption, and so on.

    g A note provides important information related to the topic, forexample, not obvious exceptions to a rule or side effects.

    t A tip provides additional information related to the topic which isnot essential in the context, but given for convenience.

    Bold All names of graphical user interface (GUI) objects, such as

    windows, field names, buttons, and so on.

    Example: Select the Full Screencheck box and press OK.

    Terms and abbreviations which are linked to an entry in theglossary and list of abbreviations respectively

    Important key words

    Italic Files, folders, and file system paths.

    Example:/usr/etc/sbin/ftpd.exe

    Emphasized words

    typewriter Input to be typed in a command line or a GUI field.

    Examples:

    ping -t 192.168.0.1

    Enter Worldin the Domainfield.

    Output from a command, error messages, content of a statusline, and so on

    File content, such as program sources, scripts, logs, and

    settings

    Placeholders, for example as part of a file name or field value.

    Examples:

    .pngor :

    Table 3 List of symbols and conventions

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    9/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    9

    IDU and Accessories Order Codes Reference Preface

    Screenshots of the graphical user interface are examples only to illustrate principles.

    This especially applies to a software version number visible in a screenshot.

    1.5 Waste electrical and electronic equipment (WEEE)

    All waste electrical and electronic products must be disposed of separately from the

    municipal waste stream via designated collection facilities appointed by the government

    or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.

    Figure 1 WEEE label

    The correct disposal and separate collection of waste equipment will help prevent poten-

    tial negative consequences for the environment and human health. It is a precondition

    for reuse and recycling of used electrical and electronic equipment.

    For more detailed information about disposal of such equipment, please contact Nokia

    Siemens Networks.

    The above statements are fully valid only for equipment installed in the countries of the

    European Union and is covered by the directive 2002/96/EC. Countries outside the

    [square brackets] A key to be pressed on a PC keyboard, for example [F11].

    Keys to be pressed simultaneously are concatenated with a +

    sign, for example [CTRL]+[ALT]+[DEL].

    Keys to be pressed one after another are concatenated with

    spaces, for example [ESC] [SPACE] [M].

    > The greater than symbol > is used to concatenate a series of

    GUI items in order to depict a GUI path. This is an abridged pre-

    sentation of a procedure to be carried out in order to perform an

    action or display a window or dialog box.

    Examples:

    A simple menu path: File> Save as ...

    A more complex GUI path:> Nokia Siemens Networks TransNetwindow > Filemenu >

    Change Passwordcommand > Change Passworddialog box

    x

    (in card names)

    For convenience, card names are sometimes listed with a lower

    case x variable, in order to concisely represent multiple cards.

    Example:

    I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)

    Representation Meaning

    Table 3 List of symbols and conventions (Cont.)

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    10/21

    10 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferencePreface

    European Union may have other regulations regarding the disposal of electrical and

    electronic equipment.

    1.6 RoHS complianceFlexiPacket Hub 800 complies with the European Union RoHS Directive 2002/95/EC on

    the restriction of use of certain hazardous substances in electrical and electronic equip-

    ment.

    The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-

    brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical

    and electronic equipment put on the market after 1 July 2006.

    Materials usage information on Nokia Siemens Networks Electronic Information

    Products imported or sold in the Peoples Republic of China

    FlexiPacket Hub 800 complies with the Chinese standard SJ/T 11364-2006 on the

    restriction of the use of certain hazardous substances in electrical and electronic equip-ment. The standard applies to the use of lead, mercury, cadmium, hexavalent chro-

    mium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in

    electrical and electronic equipment put on the market after 1 March 2007.

    1.7 CE compliance

    FlexiPacket Hub 800 is in compliance with the essential requirements and other relevant

    provisions of Directive:2006/95/EC, 2004/108/EC, and 1999/5/EC.

    Figure 2 CE marking

    1.8 MEF compliance

    FlexiPacket Hub 800 operating at the NNI delivers EPL, EVPL and E-LAN service

    complies with the Metro Ethernet Forum MEF14 technical specification. FlexiPacket

    Hub 800 operating at the UNI delivers EPL, EVPL and E-LAN service complies with the

    Metro Ethernet Forum MEF9 technical specification.

    The product is marked with the CE marking

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    11/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    11

    IDU and Accessories Order Codes Reference Preface

    Figure 3 MEF certified compliant logo

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    12/21

    12 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferenceFPH800 mainboard and main hardware order codes

    2 FPH800 mainboard and main hardware order

    codes

    This chapter provides the order codes of FPH800 mainbord and its main hardware,including plug-in cards, patch panels and SFP modules.

    2.1 Mainboard order codes

    The following table contains the order codes of FPH800 base system and its main

    options for replacement.

    2.2 Plug-in cards order codes

    The following table contains the order codes of supported plug-in cards in slot 1 and slot

    2 for variant configurations.

    2.3 SFP module order codes

    The following 2 tables contain the order codes of SFP modules.

    Order code Description Note

    T555800MB.00 FPH800 base system Including mechanics,

    power supply, mainboard,

    two blank panels on the

    plug-in slots, fan unit and

    power connector kit.

    T555800USB.00 USB memory key -

    T555800FAN.00 Fan unit For spare.

    T555800FAN.HS Fan unit For service repair.

    T555800PNL.00 FPH Blank Panel For replacement.

    T555800PWK.00 Power connector kit For replacement.

    Table 4 Mainboard and main options order codes

    Order code Description Note

    T555800GBE.00 4-port GE RJ-45 Card -

    T555800GBO.00 4-port GE SFP Card -

    T555800PWI.00 2-port Power Injector Card -

    T555800E1.16 16-port E1/T1 Multi-

    Service Card

    -

    T555800FB.00 2-port FlexBus Card -

    T555800STM.00 2-port STM-1/4 MSC Card -

    Table 5 Plug-in cards order codes

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    13/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    13

    IDU and Accessories Order Codes Reference FPH800 mainboard and main hardware order codes

    g SFP module is optional.SFP may also be ordered separately for in-field upgrading.

    If two SFPs are equipped, the two SFP modules may be of different types.

    2.3.1 SFP GE module order codes

    2.3.2 SFP STM-1/4 module order codes

    Order code Description Note

    T555SFMM0.00 SFP opt. 1000 Base - SX -

    550 m, 850 nm - MM - LC

    connector

    -

    T555SFSM0.10 SFP opt. 1000 Base - LX -

    10 Km, 1310 nm - SM - LC

    connector

    -

    T555SFSM0.70 SFP opt. 1000 Base - LH -

    80 Km, 1550 nm - SM - LC

    connector

    -

    T555SFSM1.20 SFP opt. 1000 Base - LH -

    120 Km, 1550 nm - SM -

    LC connector

    -

    T555SFSM0.40 SFP opt. 1000 Base - LH -

    40 Km, 1310 nm - SM - LC

    connector

    T555SFEL0.00 SFP copper 1000 Base-T -

    100 m - RJ45 connector

    -

    Table 6 SFP GE module order codes

    Order code Description Note

    T555STM1E.00 Electrical STM-1/OC-3

    SFP

    Electrical, used for the SFP

    ports on mainboard when

    configured as STM-1.

    T555SFSTO.15 SFP STM-1/OC-3 15 Km,

    1310 nm LC connector

    Optical.

    T555SFSTO.40 SFP STM-1/OC-3 40 Km,

    1310 nm LC connector

    Optical.

    T555SFSTO.80 SFP STM-1/OC-3 80 Km,

    1550 nm LC connector

    Optical.

    T555SFPS4O.15 SFP STM-4/OC-12 15 Km,

    1310 nm LC

    Optical SFP for 2-port

    STM-1/4 MSC Card.

    Table 7 SFP STM-1/4 module order codes

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    14/21

    14 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferenceFPH800 mainboard and main hardware order codes

    2.4 Patch panels and cables order codes

    The following table contains the order codes of patch panels and the cables for exten-

    sive connection.

    2.5 Dual-IDU accessories

    The following table contains the order codes of dual-IDU accessories.

    Order code Description Note

    T555800E1P.16 16 X E1/T1 RJ48c patch

    panel

    -

    T555800E1P.17 16 X E1 BNC patch panel -

    T555800E1P.18 16 X E1 1.0/2.3 patch

    panel

    -

    Table 8 Patch Panels order codes

    Order code Description Note

    T555MDR120.02 16 X E1 cable MDR68-

    MDR68, 20 cm, 120 ohm

    E1 cable to be ordered and

    used together with E1/T1

    patch panel

    T555MDR120.00 16 X E1 cable MDR68-

    MDR68, 50 cm, 120 ohm

    E1 cable to be ordered and

    used together with E1/T1

    patch panel

    T555MDR100.20 16 X T1 cable MDR68-

    MDR68, 20 cm, 100 ohm

    T1 cable to be ordered and

    used together with E1/T1

    patch panelT555MDR100.50 16 X T1 cable MDR68-

    MDR68, 50 cm, 100 ohm

    T1 cable to be ordered and

    used together with E1/T1

    patch panel

    T555MDR100.05 16 X T1 cable MDR68-

    MDR68, 5 m, 100 ohm

    T1 cable to be ordered and

    used together with E1/T1

    patch panel

    T555MDR100.15 16 X T1 cable MDR68-

    MDR68, 15 m, 100 ohm

    T1 cable to be ordered and

    used together with E1/T1

    patch panel

    Table 9 Cables order codes for 16 X E1/T1 RJ48c patch panel

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    15/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    15

    IDU and Accessories Order Codes Reference FPH800 mainboard and main hardware order codes

    Order code Description Note

    T555800SHR.00 FPH800 dual-IDU shroud This is the shroud needed

    for intalling two FPH800together to form a dual-IDU

    system.

    T555800SMB.21 FPH800 dual-IDU shroud

    21 mounting kit

    -

    T555800DPP.00 FPH800 dual-IDU protec-

    tion panel

    This is an optional item

    used with dual-IDU

    system, functioning as a Y-

    cable hub by which other

    devices can use one cable

    to connect to two IDUs.

    T555IDUDPI.00 Dual-IDU power injector This is the new power

    injector that provides four P

    + E ports and it can also

    function as Y-cable hub.

    This item is optional,

    usually used for ODU to

    connect with one Ethernet

    cable to two IDUs and, at

    the same time, to get DC

    power from IDU over the

    cable.

    T555IDUSPL.SM Optical splitter module for

    dual-IDU protection panel

    (single mode)

    This item is optionally used

    as a plug-in module with

    dual-IDU protection panel,

    providing optical Y-cable

    function. It supports two

    GE optical ports. Note that

    it is also used for FM200

    protection patch panel

    T555200DPP.00.

    T555IDUSPL.MM Optical splitter module for

    dual-IDU protection panel(multi mode)

    -

    Table 10 Dual-IDU accessories

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    16/21

    16 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferenceFPH800 mounting and connection accessories order-ing codes

    3 FPH800 mounting and connection accesso-

    ries ordering codes

    This chapter provides the order codes for FPH800 mounting kits and connecting acces-sories.

    3.1 Mounting kits order code

    The following table contains the order codes of FPH800 mounting kits.

    3.2 Connection accessories for Ethernet copper interfaces

    The following table contains the order codes of cables and connectors for Ethernet

    copper interfaces.

    Order code Description Note

    T555IH8MK.00 FPH800 mounting kit 21

    rack

    Containing L shaped

    brackets for 21 rack.

    T555IH8MK19.00 FPH800 mounting kit 19rack

    Containing L shapedbrackets for 19 rack.

    T555FMGDK.00 Grounding kit -

    T555IDUGDK.NS FlexiPacket IDU NEBS-

    compliant grounding kit

    -

    Table 11 Mounting kits

    Order code Description Note

    T555ETRJ.08 GE RJ45 connector Shielded RJ45 8 pin plug

    connector for GE interface,

    applies to GE local (non

    radio) copper interfaces.

    FE RJ45 connector Shielded RJ45 8 pin plug

    connector for FE interface.

    T555ECR5.00 GE copper cable reel 4 pairs STP Cat6, applies

    to GE local (non radio)copper interfaces, compati-

    ble with GE RJ45 connec-

    tor, T555ETRJ.08

    FE copper cable reel 4 pairs STP Cat6, applies

    to FE copper interfaces,

    compatible with FE RJ45

    connector, T555ETRJ.08

    Table 12 Connection Accessories for Ethernet copper interfaces

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    17/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    17

    IDU and Accessories Order Codes Reference FPH800 mounting and connection accessories order-ing codes

    3.3 Connection accessories for Ethernet optical interfaces

    The following table contains the order codes of cables and connectors for Ethernet

    optical interfaces.

    g It is enough to define only one type of connector (LC - LC) for a standard reference case.For other cases (e.g. LC - FC, LC - SC), based on customers request, standard instal-

    lation material can be found by service.

    3.4 Connection accessories for STM-1/4 optical interfaces

    The same as SM fiber patch cords in Table 13.

    CS73199.05 GE copper patch cord, L =

    5 m

    Ethernet STP Cat6 cable

    with RJ45-RJ45 plug con-

    nectors for GE. Applies toGE local (non radio) copper

    interfaces.

    Order code Description Note

    Table 12 Connection Accessories for Ethernet copper interfaces (Cont.)

    Order code Description Note

    T555IGEMM.05 MM fiber patch cord, L = 5

    m

    Ethernet fiber MM cable

    with LC - LC connector for

    GE. Applies to GE local

    optical interfaces (SFP).

    T555IGEMM.30 MM fiber patch cord, L = 30

    m

    Ethernet fiber MM cable

    with LC - LC connector for

    GE. Applies to GE local

    optical interfaces (SFP).

    CS73631.05 SM fiber patch cord, L = 5

    m

    Ethernet fiber SM cable

    with LC - LC connector forGE. Applies to GE local

    optical interfaces (SFP).

    Also applies to STM-1

    optical interfaces.

    CS73631.30 SM fiber patch cord, L = 30

    m

    Ethernet fiber SM cable

    with LC - LC connector for

    GE. Applies to GE local

    optical interfaces (SFP).

    Also applies to STM-1

    optical interfaces.

    Table 13 Connection Accessories for Ethernet optical interfaces

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    18/21

    18 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferenceFPH800 mounting and connection accessories order-ing codes

    3.5 Connection accessories for FlexBus interfaces

    The following table contains the order codes of cables and connectors for FB interfaces.

    3.6 Connection accessories for E1 interfaces

    The following table contains the order codes of cables and connectors for E1 interfaces.

    Order code Description Note

    T55256.02 Flexbus cable reel, 500 m CNT-300 cable reel 500 m.

    To be ordered together

    with 2-port Flexbus Card

    T555800FB.00.

    T55255.07 IDU/ODU TNC connector,

    male

    -

    T55255.08 IDU/ODU TNC connector,

    male angle

    -

    Table 14 Connection Accessories for Flexbus interfaces

    Order code Description Note

    T555MDR120.05 16 x E1 cable MDR68 -

    MDR68, 5 m, 120 ohm

    -

    T555MDR75.05 16 x E1 cable MDR68 -

    MDR68, 5 m, 75 ohmT555MDR120.15 16 x E1 cable MDR68 -

    MDR68, 15 m, 120 ohm

    T555MDR75.15 16 x E1 cable MDR68 -

    MDR68, 15 m, 75ohm

    Table 15 Connection Accessories for 16 x E1 interface

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    19/21

    A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    19

    IDU and Accessories Order Codes Reference Software and licenses order codes

    4 Software and licenses order codesThis chapter provides the order codes of the software release and the licenses.

    4.1 Software order code

    The following table contains the order code of the basic software release.

    4.2 licenses order codes

    The following table contains the order codes of optional software licenses.

    Order code Description Note

    T555800BSW.00 Basic Software This order code is for

    invoice purpose only. The

    equipment is shipped with

    the latest software release.

    Table 16 Software order code

    Order code Description Note

    T555OAM.80 FPH800 Ethernet OAM

    license

    -

    T555STP.80 FPH800 spanning tree

    protocol license

    -

    T555LTOP.80 FPH800 1588v2 slave

    mode license

    -

    T555LSEC.80 FPH800 advanced security

    license for packet mode

    and for hybrid mode

    -

    T55580080.31 FPH800 G.8031 license -

    T55580080.32 FPH800 G.8032 license -

    T555800CE.LP FPH800 CES linear protec-

    tion license

    -

    T55580064K.E1 FPH800 n X 64 Kbps

    grooming into E1 on MB

    (mainboard)

    FPH800 n X 64 kbps TS

    grooming into E1 on MB.

    T555800MLP.00 FPH800 software license

    for MLPPP

    -

    T555800DIU.00 FPH800 software license

    for dual-IDU

    -

    Table 17 Licenses order code

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    20/21

    20 A25000-A0800-E060-01-76P1

    Issue: 1 Issue date: May 2013

    IDU and Accessories Order Codes ReferenceSoftware and licenses order codes

    4.3 In-field software upgrading kit order codes

    The following table contains the order codes of in-field software upgrading kit.

    Order code Description Note

    T555800SW2.50 FPH800 R2.5 basic

    software on e-Media

    Delivered on NOLS.

    T555800CD2.50 FPH800 R2.5 basic

    software on CDROM

    Delivered by CDROM.

    Table 18 In-field software upgrading kit order code

  • 8/10/2019 06 Idu and Accessories Order Codes Reference

    21/21

    IDU and Accessories Order Codes Reference FOC order codes

    5 FOC order codesThis chapter provides the order codes of the Flexi Outdoor Case (FOC) and its cables.

    g If the Indoor Unit (IDU) is used in the Flexi Outdoor Case, FOC alarm patch cord is used.For details on FOC use, FOC cables, accessories and mounting kits order codes, refer

    to FOC manuals.

    Order code Description Note

    T55150.10 Flexi Outdoor Case Casing

    T55150.15 Flexi Outdoor Case ext.

    Temp

    Casing with extended

    support for low tempera-

    ture

    Table 19 FOC order codes