0620 x-booster booster for blasting agentsweigth (kg) x-booster 150 1/3 lb 150 g 1.48” 37.7 mm...

2
Techical Data Sheet Products / High Explosives V0620 X-BOOSTER Booster for Blasting Agents DESCRIPTION The X-BOOSTER Cylindrical range are explosive charges of high power and high safety, intended for the initiation of blasting agents. Its plastic container protects the explosive mixture it contains, allowing it to be more insensitive to impact or rubbing, as well as a greater resistance to the attack of water present in some perforations. It also includes the Safelock ® accessory that aims at a standard and safe priming, housing the crimper of the detonator inside the booster in a single position. TRANSPORT INFORMATION High Explosive Class 1. Division 1.1D Nº UN: 0081 HDS-PEN-03 TECHNICAL CHARACTERISTICS DIMENSIONS * Density g/cc 1.62 ± 5% Typical detonation velocity* ft/s (m/s) 23,600 ± 5% (7,200 ± 5%) Minimum detonation velocity* ft/s (m/s) 21,000 (6,400) Minimum detonation pressure* (GPa) 21 Minimum energy (KJ/Kg) 5,500 Water resistance Excellent Minimum gas volume (L/Kg) 690 Relative Effective Energy to ANFO Relative Weight Strength 1.50 Relative Volume Strength 3.00 APPLICATIONS Use at least a 3 g/ft (10 g/m) Detonating Cord as an initiator. Use a detonator N°8, electric, non-electric, or greater, as priming. Use as an initiator of blasting agents such as ANFO and bulk emulsion. The guaranteed duration of this product is 5 years. STANDARD FORMAT Product Unit. Weight External diameter Length with cap Units per box Box net weigth (kg) X-BOOSTER 150 1/3 lb 150 g 1.48” 37.7 mm 5.11” 129.7 mm 96 31.7 ± 3% lb 14.4 ± 3% kg X-BOOSTER 225 1/2 lb 225 g 1.68” 42.7 mm 5.09” 129.3 mm 72 35.7 ± 3% lb 16.2 ± 3% kg X-BOOSTER 450 1 lb 450 g 2.33” 59.1 mm 5.09” 129.3 mm 36 35.7 ± 3% lb 16.2 ± 3% kg X-BOOSTER 900 2 lb 900 g 3.26” 82.7 mm 5.11” 129.7 mm 18 35.7 ± 3% lb 16.2 ± 3% kg BOX DIMENSIONS Cubic Box L x W x H 10.6” x 10.6” x 11.1" 27 x 27 x 28.3 cm PRESENTATION Pentolite bases high explosive of cylindrical shape, which is presented in different weights according to the need for initiation. MANUFACTURING Río Loa Facility, Calama, Chile Quatro Barras Facility, Curitiba, Brasil *Measured in 1 ½ x 16” test tube WARNING Enaex Servicios SA will only be responsible for what is expressly indicated in this catalog, and will not be liable in any case for damages, losses or any contingency derived from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. Enaex SA reserves the right to modify its products, without prior notice.

Upload: others

Post on 24-Dec-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 0620 X-BOOSTER Booster for Blasting Agentsweigth (kg) X-BOOSTER 150 1/3 lb 150 g 1.48” 37.7 mm 5.11” 129.7 mm 96 lb 31.7 ± 3 % 14.4 ± 3% kg X-BOOSTER 225 1/2 lb 225 g 16 1 .68”

Techical Data Sheet

Products / High Explosives

V0620

X-BOOSTER Booster for Blasting Agents

DESCRIPTION

The X-BOOSTER Cylindrical range are explosive charges of high power and

high safety, intended for the initiation of blasting agents. Its plastic container

protects the explosive mixture it contains, allowing it to be more insensitive

to impact or rubbing, as well as a greater resistance to the attack of water

present in some perforations. It also includes the Safelock ® accessory that

aims at a standard and safe priming, housing the crimper of the detonator

inside the booster in a single position.

TRANSPORT INFORMATION

High Explosive

Class 1. Division 1.1D

Nº UN: 0081

HDS-PEN-03

TECHNICAL CHARACTERISTICS DIMENSIONS *

Density g/cc 1.62 ± 5%

Typical detonation velocity* ft/s (m/s) 23,600 ± 5%

(7,200 ± 5%)

Minimum detonation velocity* ft/s (m/s) 21,000(6,400)

Minimum detonation pressure* (GPa) 21

Minimum energy (KJ/Kg) 5,500

Water resistance Excellent

Minimum gas volume (L/Kg) 690

Relative Effective Energy to ANFO

Relative Weight Strength 1.50

Relative Volume Strength 3.00

APPLICATIONS

Use at least a 3 g/ft (10 g/m) Detonating Cord as an initiator.

Use a detonator N°8, electric, non-electric, or greater, aspriming.

Use as an initiator of blasting agents such as ANFO and bulkemulsion.

The guaranteed duration of this product is 5 years.

STANDARD FORMAT

Product Unit. Weight External

diameter Length with

cap Units per

box Box net

weigth (kg)

X-BOOSTER 150 1/3 lb

150 g

1.48”

37.7 mm

5.11”

129.7 mm

96 31.7 ± 3% lb

14.4 ± 3% kg

X-BOOSTER 225 1/2 lb

225 g

1.68”

42.7 mm

5.09”

129.3 mm

72 35.7 ± 3% lb

16.2 ± 3% kg

X-BOOSTER 450 1 lb

450 g

2.33”

59.1 mm

5.09”

129.3 mm

36 35.7 ± 3% lb

16.2 ± 3% kg

X-BOOSTER 900 2 lb

900 g

3.26”

82.7 mm

5.11”

129.7 mm18

35.7 ± 3% lb

16.2 ± 3% kg

BOX DIMENSIONS

Cubic Box L x W x H 10.6” x 10.6” x 11.1" 27 x 27 x 28.3 cm

PRESENTATION

Pentolite bases high explosive of cylindrical shape, which is presented in different weights according to the need for initiation.

MANUFACTURING

• Río Loa Facility, Calama, Chile• Quatro Barras Facility, Curitiba, Brasil

* Measured in 1 ½ x 16” test tube

WARNING Enaex Servicios SA will only be responsible for what is expressly indicated in this catalog, and will not be liable in any case for damages, losses or any contingency derived from the use of the products, except

those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. Enaex SA reserves the right to modify its products, without prior notice.

Page 2: 0620 X-BOOSTER Booster for Blasting Agentsweigth (kg) X-BOOSTER 150 1/3 lb 150 g 1.48” 37.7 mm 5.11” 129.7 mm 96 lb 31.7 ± 3 % 14.4 ± 3% kg X-BOOSTER 225 1/2 lb 225 g 16 1 .68”

Technical Data Sheet Products / High Explosives V0620

X-BOOSTER Serie Booster for Blasting Agents

Safelock®

Safety accessory that prevents the detonator from being dislodged from the X-BOOSTER, during the priming or loading of explosives in the pit.

ALWAYS NEVER

1. Insert the detonator into the pass through pin of the container

2. Insert the detonator through the blind pin opening and place theshock tube as shown in the figure.

3. Adjust the detonator capsule on SAFELOCK® accessory tabs,adjusted to the detonator crimper.

1. In case of having a misfire, the detonator capsule must not beremoved from the SAFELOCK® accessory, and must only bedestroyed according to the corresponding misfire handlingprocedure.

2. Never use the X- Booter ® if the detonator is loose or if it is not fullyinserted in its hole.

WARNING Enaex Servicios SA will only be responsible for what is expressly indicated in this catalog, and will not be liable in any case for damages, losses or any con�ngency derived from the use of the products, except

those expressly indicated by the current Chilean legisla�on. The use of explosives is regulated in each country by its own laws. Enaex SA reserves the right to modify its products, without prior no�ce.

1

1

2

3

2

3

DETONATORCAPSULE

SAFELOCKADJUSTMENT

SAFELOCK NO

NO

OR

SAFELOCK

SHOCK TUBE

DETONATORCAPSULE

SAFELOCKADJUSTMENT

SHOCK TUBE