  • OptiX iManager T2000 Operation Manual for SDH Contents

    Huawei Technologies Proprietary

    i

    Contents

    7 Configuring Service over Trail 7-1

    7.1 Configuring SDH Service over Trail 7-2

    7.1.1 Creating VC4 Trail 7-2

    7.1.2 Creating Common VC12/VC3 Trail 7-4

    7.1.3 Creating SNCP VC12/VC3 Trail 7-5

    7.1.4 Viewing Trail 7-7

    7.1.5 Configuring Trace Byte over Trail 7-8

    7.1.6 Configuring C2 Byte over Trail 7-9

    7.1.7 Setting Overhead Termination over Trail 7-11

    7.1.8 Deleting SDH Trail 7-12

    7.2 Configuring Ethernet Service over Trail 7-14

    7.2.1 Creating EPL Service 7-14

    7.2.2 Creating EVPL Service 7-19

    7.2.3 Creating EPLn Service 7-26

    7.2.4 Deleting Ethernet Trail 7-33

    7.2.5 Deleting Trunk Link Trail 7-33

  • OptiX iManager T2000 Operation Manual for SDH Figures

    Huawei Technologies Proprietary

    ii

    Figures

    Figure 7-1 Example of EPL application 7-14

    Figure 7-2 Example of EVPL application 7-19

    Figure 7-3 Example of EPLn application 7-26

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-1

    7 Configuring Service over Trail This chapter introduces how to configure SDH service and Ethernet service over trail. The following tasks are described:

    Configuring SDH Service over Trail

    Configuring Ethernet Service over Trail

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-2

    7.1 Configuring SDH Service over Trail

    7.1.1 Creating VC4 Trail

    Purpose

    Before deleting a VC4 trail, the trail for lower level service carried by this trail should be deleted first.

    The VC4 trail can carry the service between source NE and sink NE only. Other NEs between the source NE and sink NE can not use the VC4 trail. So the VC4 trail is usually created between adjacent NEs instead of passing through several NEs to fully utilize bandwidth.

    Prerequisites

    NM user with the authority of "system operator" or above.

    A protection subnet has been created.

    The license used by the customer supports the trail management function.

    Procedure

    Step Action 1 Select [Trail/Fast Creation] in the Trail View.

    2 Set the service direction to Bidirectional and level to VC4.

    3 Configure the Resource Usage Strategy and Protection Priority Strategy.

    4 Double-click the source NE and the sink NE in turn. The route selected automatically will be displayed between the NEs.

    5 Click a server layer trail on the right to specify the inevitable route. It will be displayed in pink. Click that trail again to turn it gray, and it means that the selection is cancelled. (Optional)

    Note: This step is optional. In most situations, you do not need to specify the inevitable route.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-3

    Step Action 6 Double-click NE icons to specify the nodes which are not allowed to be

    passed by the trail. The selected NE will be marked with a (double-clicking them again can cancel the selection). (Optional)

    Note: This step is optional. In most situations, you do not need to appoint the NE not allowed to be passed.

    7 Click . The dialog box Set Route Timeslot is displayed. Select the timeslot and click .(Optional)

    Note: This step is optional. If you do not assign the timeslot, timeslot 1 will be selected automatically.

    8 Select the Activate combo box.

    9 Select the Copy after Creation combo box if you want to create multiple trails with the same route. Click .(Optional)

    10 The Operation Result dialog box is displayed and indicates operation succeeded. Click .

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-4

    7.1.2 Creating Common VC12/VC3 Trail

    Purpose

    The VC12/VC3 trail is the end-to-end service trail between NEs. Only with the VC4 service layer trail created between source and sink NEs and there is redundant E1/E3 timeslots on that, the VC12/VC3 trail can be created.

    Prerequisites

    NM user with the authority of "system operator" or above.

    A VC4 trail has been created.

    The license used by the customer supports the trail management function.

    Procedures

    Step Action 1 Select [Trail/Fast Creation] in the Trail View.

    2 Select the service direction according to the type of the protection subnet. Set the service level to E1/T1 or E3/T3.

    3 Configure the Resource Usage Strategy and Protection Priority Strategy.

    4 Double-click the source NE and the sink NE in turn. Select the port in the dialog box Create Trail and click . The route selected automatically will be displayed between the NEs.

    5 Click a server layer trail on the right to specify the inevitable route. It will be displayed in pink. Click that trail again to turn it gray, and it means that the selection is cancelled. (Optional)

    Note: This step is optional. In most situations, you do not need to specify the inevitable route.

    6 Double-click NE icons to specify the nodes which are not allowed to be passed by the trail. The selected NE will be marked with a (double-clicking them again can cancel the selection). (Optional)

    Note: This step is optional. In most situations, you do not need to appoint the NE not allowed to be passed.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-5

    Step Action 7 Click . The dialog box Set Route Timeslot is

    displayed. Select the timeslot and click .(Optional)

    Note: This step is optional. If you do not assign the timeslot, timeslot 1 will be selected automatically.

    8 Select the Activate combo box.

    9 Select the Copy after Creation combo box if you want to create multiple trails with the same route. Click .(Optional)

    10 The Operation Result dialog box is displayed and indicates operation succeeded. Click .

    7.1.3 Creating SNCP VC12/VC3 Trail

    Purpose

    Use this procedure to create trail with SNCP.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-6

    Prerequisites

    NM user with the authority of "system operator" or above.

    A VC4 trail has been created.

    The license used by the customer supports the trail management function.

    Procedure

    Step Action 1 Select [Trail/Creation Wizard] in the Trail View.

    2 Set the service direction to Unidirectional and level to E1/T1 or E3/T3.

    3 Set the resource usage strategy to Protected Resource and the protection priority strategy to SNCP First. Click .

    4 Double-click the source NE and the sink NE in turn. Select the port in the dialog box Create Trail and click . Click . The route selected automatically will be displayed between the NEs.

    5 Click a server layer trail on the right to specify the inevitable route. It will be displayed in pink. Click that trail again to turn it gray, and it means that the selection is cancelled. (Optional)

    Note: This step is optional. In most situations, you do not need to specify the inevitable route.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-7

    Step Action 6 Double-click NE icons to specify the nodes which are not allowed to be

    passed by the trail. The selected NE will be marked with a (double-clicking them again can cancel the selection). (Optional)

    Note: This step is optional. In most situations, you do not need to appoint the NE not allowed to be passed.

    7 Click . The dialog box Set Route Timeslot is displayed. Select the timeslot and click . Click .(Optional)

    Note: This step is optional. If you do not assign the timeslot, timeslot 1 will be selected automatically.

    8 Double-click the dual-fed node, the node is displayed as . Double-click the selectively-received node, the node is displayed as . The node clicked first will be the dual-fed node. Click .

    9 Select the Activate combo box.

    10 Select the Copy after Creation combo box if you want to create multiple trails with the same route. Click .(Optional)

    11 The Operation Result dialog box is displayed and indicates operation succeeded. Click .

    7.1.4 Viewing Trail

    Purpose

    Use this procedure to view trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-8

    Prerequisites

    NM user with the authority of "system operator" or above.

    Trails have been created.

    Procedure

    Step Action 1 Select [Trail/Trail Management] in the Trail View. Click in the

    Prompt dialog box.

    2 Click . The dialog box Set Trail Browse Filter Conditions is displayed.

    3 Set the filter conditions and click . The trails are displayed.

    Note: Full filter is to filter all trails in a network, secondary filter is to filter a trail already displayed in the interface according to the re-set filtering conditions, and incremental filter is to filter a newly added trail not displayed in the interface.

    4 Select a trail, the detailed information is displayed below.

    5 Click or and select the status information you want to view.

    7.1.5 Configuring Trace Byte over Trail

    Purpose

    Use this procedure to configure the trace byte over trail.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    E1/E3 trails have been created.

    Procedure

    Step Action 1 Select [Trail/Trail Management] in the Trail View. Click in the

    Prompt dialog box.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-9

    Step Action 2 Click . The dialog box Set Trail Browse Filter Conditions is

    displayed.

    3 Set the filter conditions and click . The trails are displayed.

    Note: Full filter is to filter all trails in a network, secondary filter is to filter a trail already displayed in the interface according to the re-set filtering conditions, and incremental filter is to filter a newly added trail not displayed in the interface.

    4 Select a trail, the detailed information is displayed below.

    5 Click and select Trace Byte.

    6 Click in the prompt dialog box. The Set Overhead dialog box is displayed.

    7 Double-click the trace byte to modify it. Click .

    8 Click to confirm the operation. The Operation Result dialog box is displayed and indicates operation succeeded. Click .

    7.1.6 Configuring C2 Byte over Trail

    Purpose

    Use this procedure to configure the C2 byte over trail.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    E1/E3 trails have been created.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-10

    Procedure

    Step Action 1 Select [Trail/Trail Management] in the Trail View. Click in the

    Prompt dialog box.

    2 Click . The dialog box Set Trail Browse Filter Conditions is displayed.

    3 Set the filter conditions and click . The trails are displayed.

    Note: Full filter is to filter all trails in a network, secondary filter is to filter a trail already displayed in the interface according to the re-set filtering conditions, and incremental filter is to filter a newly added trail not displayed in the interface.

    4 Select a trail, the detailed information is displayed below.

    5 Click and select C2 Byte.

    6 Click in the prompt dialog box. The Set Overhead dialog box is displayed.

    7 Double-click the C2 byte to modify it. Click .

    8 Click to confirm the operation. The Operation Result dialog box is displayed and indicates operation succeeded. Click .

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-11

    7.1.7 Setting Overhead Termination over Trail

    Purpose

    Use this procedure to set overhead termination status over trail.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    Trails have been created.

    Procedure

    Step Action 1 Select [Trail/Trail Management] in the Trail View. Click in the

    Prompt dialog box.

    2 Click . The dialog box Set Trail Browse Filter Conditions is displayed.

    3 Set the filter conditions and click . The trails are displayed.

    Note: Full filter is to filter all trails in a network, secondary filter is to filter a trail already displayed in the interface according to the re-set filtering conditions, and incremental filter is to filter a newly added trail not displayed in the interface.

    4 Select a trail, the detailed information is displayed below.

    5 Click and select Overhead Termination.

    6 Click in the prompt dialog box. The Set Overhead dialog box is displayed.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-12

    Step Action 7 Select the overhead status and click .

    8 Click to confirm the operation. The Operation Result dialog box is displayed and indicates operation succeeded. Click .

    7.1.8 Deleting SDH Trail

    Purpose

    Use this procedure to delete SDH trail, including service trail and client trail.

    Note: Delete a service layer trail in the same way as deleting a service trail. But before deleting a service layer trail, remove the service trails from the service layer trail first.

    If you want to delete a SDH trail which is used for a trunk link trail, you need to delete the trunk link trail first. For details, refer to 7.2.5 Deleting Trunk Link Trail.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    Make sure the SDH trail to delete is Unactivated.

    Make sure the SDH trail is not used for any trunk link trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-13

    Procedure

    Step Action 1 Select [View/Trail View] and select [Trail/Trail Management] in the Trail

    View. Click in the Prompt dialog box.

    2 Click . The dialog box Set Trail Browse Filter Conditions is displayed.

    3 Select the SDH trail to delete and right-click it, select [Delete].

    4 Click to delete the SDH trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-14

    7.2 Configuring Ethernet Service over Trail

    7.2.1 Creating EPL Service

    Purpose

    The Ethernet Private Line (EPL) service is a simple type of leased line service. It can realize point-to-point connection of service, but the VCTRUNK ports occupied by each service are independent, as shown in the diagram below.

    TrunkLink1

    VCTRUNK 1

    MAC1

    MAC2

    VCTRUNK 1

    TrunkLink2VCTRUNK2 VCTRUNK1 MAC1

    MAC1

    A A'

    NE 1 NE 2 NE 3

    B B'

    Figure 7-1 Example of EPL application

    To use the trail function to create an EPL service, you can configure the Ethernet service from the angle of networking, thus simplifying the configuration process.

    Prerequisites

    NM user with the authority of "system operator" or above.

    Fibers and protection subnet have been created at the network layer.

    The Ethernet processing board and the corresponding interface board have been installed.

    Procedure

    1. Creating service trail Step Action 1 Create VC4 trail. The detailed operations are described in 7.1.1

    Creating VC4 Trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-15

    Step Action 2 Create the lower order path trail (VC12 trail or VC3 trail) (Optional).

    The detailed operations are described in 7.1.2 Creating Common VC12/VC3 Trail or 7.1.3 Creating SNCP VC12/VC3 Trail.

    Note: You can skip this step. When creating a Trunk Link Trail, you can also create a lower order path trail.

    2. Creating Trunk Link trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Trunk Link] in the Trail View.

    2 Set the Bandwidth.

    3 Select the Automatically create service trail. (Optional)

    Note: If no VC3/VC12 trail has been created in advance. Here you need to select Automatically create service trail, indicating that you can create a lower order path trail when creating a Trunk Link trail. If a VC3/VC12 trail has been created, you can skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-16

    Step Action 4 Set the Source and Sink. Click to select the appropriate

    VCTRUNK ports.

    Note: 1) If you have executed Step 3, you need to select the Bound Timeslot in addition to the VCTRUNK port.

    2) If you have not executed Step 3, you need to select the VCTRUNK port only.

    3) You need to keep the bandwidth of the Source/Sink VCTRUNK consistent with that set in Step 2.

    5 Set the VCTRUNK port attribute. Click , the Port Attribute Setting dialog box is displayed. Set the port attributes.

    Note: Here you configure the EPL service only, so the value of Port Type is PE.

    6 In Available Trail, select an appropriate lower order path trail as the Trunk Link tail at the service layer. (Optional)

    Note: If you have not executed Step 3, skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-17

    Step Action 7 Enter the information about this Trunk Link trail, such as Name, ID

    and Remarks.(Optional)

    Note: If you use the default value, skip this step.

    8 Activate the Trunk Link trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the Trunk Link, but to activate it as required after creating it.

    9 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    10 Repeat this procedure to create as many Trunk Link trails as necessary.

    3. Creating EPL trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Ethernet Trail/Create EPL] in the Trail View.

    2 Set source and sink EPL trail. Select Usage Strategy of source and sink. Click to select appropriate MAC port. If the value of Usage Strategy is PORT+VLAN, the VLAN ID should be set.

    Note: Usage Strategy has two ways.

    1) PORT: To configure transmit EPL service transparently, applied in point-to-point communication usually. The VLAN ID is not editable.

    2) PORT+VLAN: To configure convergence EPL service, applied in point-to-point, point-to-multipoint communication or communication among points.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-18

    Step Action 3 Set Trunk Link trail. First, you should select trail strategy of Trunk

    Link, following which to perform the next operation.

    Strategy 1: Automatically Create Trunk Link.

    Here, you need to set the bandwidth of the Trunk Link, click .

    Strategy 2: Manually Create Trunk Link.

    Click to create the Trunk Link trail. For detailed operation, see 2. Creating Trunk Link trail.

    After that, click to return to step 2 and complete the setting.

    The default value of the Trunk Link trail strategy is Use Existing Trunk Link. Select the created Trunk Link trail and click .

    Strategy 3: Use Existing Trunk Link.

    Select a proper Trunk Link trail, click .

    Note: 1) Trunk Link trail strategy lies on the application in practice. Therefore, it is recommended to create Trunk Link trail first, and then create the Ethernet trail. In Use Existing Trunk Link, take the default value.

    2) Manually Create Trunk Link and Automatically Create Trunk Link are used for service expansion. In the former one, the source/sink of the Trunk Link need to be configured manually, but the timeslot can be allocated as required. In the latter one, the source/sink of the Trunk Link can be configured automatically, but the timeslot cannot be allocated flexibly.

    4 Set port attributes. Set TAG, LCAS Enabled, Encapsulation Protocol, Port Enable and Entry Detection in Port Attribute Setting.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-19

    Step Action 5 Enter the information about this EPL trail, such as Name, ID and

    Remarks.(Optional)

    Note: If you use the default value, skip this step.

    6 Activate the EPL trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the EPL trail, but to activate it as required after creating it.

    7 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    8 Repeat this procedure to create as many EPL trails as necessary.

    7.2.2 Creating EVPL Service

    Purpose

    The difference between the Ethernet Virtual Private Line (EVPL) and EPL is that the EVPL can share the VCTRUNK port, as shown in the following diagram. Therefore, EPL can be regarded as a special application of EVPL.

    TrunkLink1VCTRUNK 1

    MAC1

    MAC2 VCTRUNK 1 MAC2

    MAC1

    A A'

    NE 1 NE 2

    B B'

    Figure 7-2 Example of EVPL application

    To use the trail function to create an EVPL service, you can configure the Ethernet service from the angle of networking, thus simplifying the configuration process.

    Prerequisites

    NM user with the authority of "system operator" or above.

    Fibers and protection subnet have been created at the network layer.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-20

    The Ethernet processing board and the corresponding interface board have been installed.

    Procedure

    1. Creating service trail Step Action 1 Create VC4 trail. The detailed operations are described in 7.1.2

    Creating Common VC12/VC3 Trail or 7.1.3 Creating SNCP VC12/VC3 Trail.

    2 Create the lower order path trail (VC12 trail or VC3 trail) (Optional). The detailed operations are described in 7.1.2 Creating Common VC12/VC3 Trail.

    Note: You can skip this step. When creating a Trunk Link trail, you can also create a lower over path trail.

    2. Creating Trunk Link trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Trunk Link] in the Trail View.

    2 Set the Bandwidth.

    3 Select the Automatically create service trail. (Optional)

    Note: If no VC3/VC12 trail has been created in advance. Here you need to select Automatically create service trail, indicating that you can create a lower order path trail when creating a Trunk Link trail. If a VC3/VC12 trail has been created, you can skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-21

    Step Action 4 Set the Source and Sink. Click to select the appropriate

    VCTRUNK ports.

    Note: 1) If you have executed Step 3, you need to select Bound Timeslot in addition to the VCTRUNK port.

    2) If you have not executed Step 3, you need to select the VCTRUNK port only.

    3) You need to keep the bandwidth of the source/sink VCTRUNK consistent with that set in Step 2.

    5 Set the VCTRUNK port attribute. Click , the Port Attribute Setting dialog box is displayed. Set the port attributes.

    6 In Available Trail", select a proper lower order path trail as the Trunk Link trail at the service layer.

    Note: If you have not executed Step 3, skip this step.

    7 Enter the information about this Trunk Link trail, such as Name, ID and Remarks.(Optional)

    Note: If you use the default value, skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-22

    Step Action 8 Activate the Trunk Link trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the trunk link trail, but to activate it as required after creating it.

    9 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    10 Repeat this procedure to create as many Trunk Link trails as necessary.

    3. Creating EVPL trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Ethernet Trail/Create EVPL] in the Trail View.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-23

    Step Action 2 Set source and sink of EVPL. Select Usage Strategy of source and

    sink. Click to select appropriate MAC port. If the value of Usage Strategy is PORT+VLAN, the VLAN ID should be set. If the value of Usage Strategy is PORT+MPLS, the Tunnel flag should be set.

    Note: Usage Strategy has three ways:

    1) PORT: To configure transparently-transmitted EVPL service, applied in point-to-point communication usually. The VLAN ID is not editable.

    2) PORT+VLAN: To configure convergence EVPL service, applied in point-to-point, point-to-multipoint communication or communication among points.

    3) PORT+MPLS: To share VCTRUNK through MPLS. This is the difference between EVPL and EPL service.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-24

    Step Action 3 Set Trunk Link trail. First, you should select trail strategy of Trunk

    Link, following which to perform the next operation.

    Strategy 1: Automatically Create Trunk Link.

    Here, you need to set the bandwidth of the Trunk Link, click .

    Strategy 2: Manually Create Trunk Link.

    Click to create the Trunk Link trail. For detailed operation, see 2. Creating Trunk Link trail.

    After that, click to return to step 2 and complete the setting.

    The default value of the Trunk Link trail strategy is Using Existing Trunk Link. Select the created Trunk Link trail and click .

    Strategy 3: Use Existing Trunk Link.

    Select a proper Trunk Link trail, click.

    Note: 1) Trunk Link trail strategy lies on the application in practice. Therefore, it is recommended to create Trunk Link trail first, and then create the Ethernet trail. In Use Existing Trunk Link, take the default value.

    2) Manually Create Trunk Link and Automatically Create Trunk Link are used for service expansion. In the former one, the source/sink of the Trunk Link need to be configured manually, but the timeslot can be allocated as required. In the latter one, the source/sink of the Trunk Link can be configured automatically, but the timeslot cannot be allocated flexibly.

    4 Set port attributes. Set TAG, LCAS Enabled, Encapsulation Protocol, Port Enable and Entry Detection in Port Attribute Setting.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-25

    Step Action 5 Enter the information about this EVPL trail, such as Name, ID and

    Remarks.(Optional)

    Note: If you use the default value, skip this step.

    6 Activate the EVPL trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the trunk link trail, but to activate it as required after creating it.

    7 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    8 Repeat this procedure to create as many EVPL trails as necessary.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-26

    7.2.3 Creating EPLn Service

    Purpose

    The Ethernet LAN service is added with MPLS or Stack VLAN protocol for processing on the basis of the original Layer 2 switching service, achieving fast forwarding and VCTRUNK bandwidth sharing. Logically the whole Ethernet LAN domain can be regarded as a huge switch. A user can access the switch from any ports in the domain. The port of this switch supports Layer 2 protocols, such as spanning tree and Internet group management protocol (IGMP Snooping).

    The Ethernet private LAN (EPLn) is a simple application of the Ethernet LAN service. In this case, the VCTRUNK port cannot be shared.

    NE1

    VCTRUNK1MAC1

    Marketing Dept (VLAN1)

    MAC2 VCTRUNK2

    Technical Dept (VLAN2)

    VB1

    TrunkLink1

    TrunkLink2

    VB1

    MAC1

    MAC2

    NE2

    VCTRUNK1

    VCTRUNK2

    Marketing Dept (VLAN1)

    Technical Dept (VLAN2)

    Figure 7-3 Example of EPLn application

    To use the trail function to create an EPLn service, you can configure the Ethernet service from the angle of networking, thus simplifying the configuration process.

    Prerequisites

    NM user with the authority of "system operator" or above.

    Fibers and protection subnet have been created at the network layer.

    The Ethernet processing board and the corresponding interface board have been installed.

    Procedure

    1. Creating service trail Step Action 1 Create VC4 trail. The detailed operations are described in 7.1.2

    Creating Common VC12/VC3 Trail or 7.1.3 Creating SNCP VC12/VC3 Trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-27

    Step Action 2 Create the lower order path trail (VC12 trail or VC3 trail) (Optional).

    The detailed operations are described in 7.1.2 Creating Common VC12/VC3 Trail.

    Note: You can skip this step. When creating a Trunk Link trail, you can also create a lower over path trail.

    2. Creating Trunk Link trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Trunk Link] in the Trail View.

    2 Set the Bandwidth.

    3 Select the Automatically create service trail. (Optional)

    Note: If no VC3/VC12 trail has been created in advance. Here you need to select Automatically create service trail, indicating that you can create a lower order path trail when creating a Trunk Link trail. If a VC3/VC12 trail has been created, you can skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-28

    Step Action 4 Set the Source and Sink. Click to select the appropriate

    VCTRUNK ports.

    Note: 1) If you have executed Step 3, you need to select Bound Timeslot in addition to the VCTRUNK port.

    2) If you have not executed Step 3, you need to select the VCTRUNK port only.

    3) You need to keep the bandwidth of the source/sink VCTRUNK consistent with that set in Step 2.

    5 Set the VCTRUNK port attribute. Click , the Port Attribute Setting dialog box is displayed. Set the port attributes.

    Note: Here you configure the EPLn service only, so the value of Port Type is PE.

    6 In Available Trail", select a proper lower order path trail as the Trunk Link trail at the service layer. (Optional)

    Note: If you have not executed Step 3, skip this step.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-29

    Step Action 7 Enter the information about this Trunk Link trail, such as Name, ID

    and Remarks.(Optional)

    Note: If you use the default value, skip this step.

    8 Activate the Trunk Link trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the trunk link trail, but to activate it as required after creating it.

    9 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    10 Repeat this procedure to create as many Trunk Link trails as necessary.

    3. Creating EPLn trail Step Action 1 Select [View/Trail View] from the Main Menu. Select [Trail/Create

    Ethernet Trail/Create EPLn] in the Trail View.

    2 Set the value of Service Type to EPLn.

    3 Double-click the appropriate NE in the Trail View. The Create Trail-Select Board Port-Source-NE name is displayed.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-30

    Step Action 4 Select an appropriate board in the Slot Diagram. Select appropriate

    ports in the Available Ports and click the double-right-arrow button. Click to finish selecting ports.

    5 Repeat step 3 and step 4 to select as many nodes as necessary.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-31

    Step Action 6 Set Trunk Link trail. First, you should select the trail strategy of Trunk

    Link, following which to perform the next operation.

    Strategy 1: Select Trunk Link.

    Select a proper Trunk Link trail, click .

    Strategy 2: Create Trunk Link.

    Click to create the Trunk Link trail. For detailed operation, see 2. Creating Trunk Link trail.

    After that, click to return to step 2 and complete the setting.

    The default value of the Trunk Link trail strategy is Use Existing Trunk Link. Select the created Trunk Link trail and click .

    Note: 1) Trunk Link trail strategy lies on the application in practice. Therefore, it is recommended to create Trunk Link trail first, and then create the Ethernet trail. In Select Trunk Link, take the default value.

    2) Create Trunk Link is usually used for service expansion.

    7 Set port attributes of all the ports in this Ethernet trail.

    8 Create VLAN. Click in the VLAN Configuration. The VLAN Configuration for Ethernet Trail dialog box is displayed.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-32

    Step Action 9 Enter VLAN ID, select appropriate mounted ports in the Available

    Mounted Ports tree, click .

    10 Click or . Repeat step8~10 to create as many VLANs as necessary.

    11 Click .

    12 Activate the EPLn trail. Select Activate.(Optional)

    Note: Here, you can also select not to activate the EPLn trail, but to activate it as required after creating it.

    13 Click . The Operation Result dialog box is displayed and indicates that the operation succeeded.

    14 Repeat this procedure to create as many EPLn trails as necessary.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-33

    7.2.4 Deleting Ethernet Trail

    Purpose

    Use this procedure to delete Ethernet trail.

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    Make sure the Ethernet trail to delete is Unactivated.

    Procedure

    Step Action 1 Select [View/Trail View] and select [Trail/Ethernet Trail Management]

    in the Trail View.

    2 Select the Ethernet trail to delete and right-click it, select [Delete].

    3 Click to delete the Ethernet trail.

    7.2.5 Deleting Trunk Link Trail

    Purpose

    Use this procedure to delete Trunk Link trail.

    Note: If you want to delete a Trunk Link trail which is used for an Ethernet trail, you need to delete the Ethernet trail first. For details, refer to 7.2.4 Deleting Ethernet Trail.

  • OptiX iManager T2000 Operation Manual for SDH 7 Configuring Service over Trail

    Huawei Technologies Proprietary

    7-34

    Prerequisites

    NM user with the authority of "system maintainer" or above.

    Make sure the Trunk Link trail to delete is Unactivated.

    Make sure the Trunk Link trail to delete is used for any Ethernet trail.

    Procedure

    Step Action 1 Select [View/Trail View] and select [Trail/Trunk Link Trail

    Management] in the Trail View.

    2 Select the Trunk Link trail to delete and right-click it, select [Delete].

    3 Delete the trunk link trail according to required.

    Note: The service trail is a SDH trail which used to the trunk link.