07/000 t rotary switches, p switch-disconnectors · moeller hpl0211-2001/2002 t rotary switches, p...
TRANSCRIPT
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-Disconnectors
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/000
07/001Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOverview
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
T rotary switches, P switch-disconnectors TM mini rotary switches
Page PageOverview of functions 07/002 Overview of functions 07/002
Technical overview 07/004 Technical overview 07/004
System overview 07/006 System overview 07/072
Key to type references, modular system 07/010 Key to type references, modular system 07/010
On-Off switches On-Off switchesMain switches 07/012 Control circuit isolators 07/074On-Off switches 07/018 On-Off switches 07/074Safety switches 07/024
Control switches Control switchesChangeover switches 07/026 Changeover switches 07/075Reversing switches 07/032 Reversing switches 07/082Star-delta switches 07/032 Step switches 07/077Multi-speed switches 07/034 On-Off switches 07/081Step switches 07/036 Hand/Auto switches 07/076On-Off switches 07/040 On-Off switches, spring-return 07/081Hand/Auto switches 07/042 Coding switches 07/082On-Off switches, spring-return 07/044 Group switches 07/080Universal control switches 07/046Coding switches 07/046Series switches 07/046Instrument selector switches 07/048
Switches with locking arrangementsPanic switches 07/050On-Off switches 07/050Hand/Auto switches 07/052
Accessories AccessoriesFront plates 07/054 Key operation 07/083Key operation 07/058Additional accessories 07/060
Non-standard switches Non-standard switchesT0 rotary switches 07/084 TM mini rotary switches 07/088T3 rotary switches 07/085T5B rotary switches 07/086T5 rotary switches 07/087Bulk packaged switches 07/088
Technical data 07/090 Technical data 07/095
Dimensions 07/096 Dimensions 07/108
Ordering of non-standard switches 07/110 Ordering of non-standard switches 07/110
For other standard contact sequences, see catalogue K115
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOverview of Functions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/002
Function Flush mounting .../E...
Centre mounting.../EZ...
Surface mounting.../I...
Distribution board mounting.../IVS...
Rear mounting.../Z...
On-Off switchesMain switchesMaintenance switchesFor use as Emergency-Stop devices1)
a 07/012
a 07/013
a 07/013
Main switchesMaintenance switcheswith auxiliary contactsFor use as Emergency-Stop devices1)
a 07/014
a 07/015
a 07/015
Main switches Maintenance switches
a 07/013
a 07/013
a 07/013
Main switchesMaintenance switches with auxiliary contacts
a 07/015
a 07/015
a 07/015
On-Off switches with black thumb-grip
a 07/016
a 07/019
a 07/019
a 07/019
a 07/019
a 07/074
a 07/074
On-Off switches with black thumb-gripWith auxiliary contacts
a 07/020
a 07/021
a 07/021
a 07/021
a 07/021
On-Off switchesFor use as Emergency-Stop devices1)
a 07/022
a 07/023
a 07/023
Control circuit isolators
a 07/074
Safety switches 25 – 100 AFor use as Emergency-Stop devices1)
a 07/024
Safety switches 25 – 100 A
a 07/025
Notes 1) To IEC/EN 60 204-1;With red thumb-grip and yellow front plate
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/003Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOverview of Functions
Function Flush mounting .../E...
Centre mounting.../EZ...
Surface mounting.../I...
Distribution board mounting.../IVS...
Rear mounting.../Z...
Control switchesChangeover switchesMains transfer-, group switches
a 07/026
a 07/027
a 07/027
a 07/027
a 07/027
a 07/075
a 07/075
Reversing switches
a 07/032
a 07/033
a 07/033
a 07/033
a 07/033
a 07/082
a 07/082
Star-delta switches
a 07/032
a 07/033
a 07/033
a 07/033
a 07/033
Multi-speed switches
a 07/034
a 07/035
a 07/035
a 07/035
a 07/035
Step switches
a 07/036
a 07/036
a 07/037
a 07/037
a 07/037
a 07/077
a 07/077
On-Off switches, changeover switches
a 07/040
a 07/040
a 07/041
a 07/041
a 07/041
a 07/081
a 07/081
Hand/Auto switches
a 07/042
a 07/042
a 07/043
a 07/043
a 07/043
a 07/076
a 07/076
Spring-return switches
a 07/044
a 07/044
a 07/045
a 07/045
a 07/045
a 07/081
a 07/081
Universal control switches
a 07/046
a 07/046
a 07/047
a 07/047
a 07/047
Coding switches
a 07/046
a 07/046
a 07/047
a 07/047
a 07/047
a 07/082
a 07/082
Series switches
a 07/046
a 07/046
a 07/047
a 07/047
a 07/047
Instrument selector switches(voltage)
a 07/048
a 07/048
a 07/049
a 07/049
a 07/049
Instrument selector switches(current)
a 07/048
a 07/048
a 07/049
a 07/049
a 07/049
Switches with locking arrangements
a 07/050
a 07/051
a 07/051
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsTechnical Overview
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/004
Switch sizeTM T0 T3 T5B
Three-phase motor rating AC-3 220 – 240 V kW 1.5 3 6.5 15380 – 440 V kW 2.2 4 12 22690 V kW – 4 15 22
AC-23 220 – 240 V kW 1.8 3.5 7.5 18.5380 – 440 V kW 3 6.5 13 22690 V kW – – – 22
Rated operational current AC-21 380 – 440 V 3~ A 10 20 32 63AC-15 220 – 240 V A 2.5 6 10 16
380 – 415 V A 1.5 4 6 6Rated uninterrupted current A 10 20 32 63
Mounting formType Degree of protection
Surface mounting1)
.../I... IP65 –
K
K
K
.../I 45/... – – – –
.../I 48/... – – – –
.../ST/... –
K
K
K
Surface mounting main switch1)
.../I.../SVB... IP65 –
K
K
K
.../ST/SVB... –
K
K
K
Flush mounting.../E... Front IP65
K
K
K
K
Flush mounting main switch/flush mounting control circuit isolator
.../EA/SVB... Front IP65 –
K
K
K
TM.../E/SVB
K – – –
Centre mounting.../EZ... Front IP65 –
K
K –TM.../EZ
K – – –
Rear mounting.../Z... Front IP65 –
K
K
K
Rear mounting main switches.../V/SVB... Front IP65 –
K
K
K
Service distribution board mounting.../IVS... Front IP30
K
K – –
Notes 1) Enclosures for metric cable glands to EN 50 262, cable glands
a Page 07/070
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/005Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsTechnical Overview
T5 T6-2 T6-3-8212 T6-160-6 T8-3-8342 T8-3-8212 P1 P318.5 22 22 22 37 37 5.5 7.5 15 2230 37 37 45 55 55 7.5 13 30 3730 22 22 22 37 37 7.5 15 30 37
18.5 37 37 37 75 75 7 8.5 18.5 3030 45 45 55 132 132 13 15 37 5030 30 30 30 37 37 11 18.5 30 75
100 125 125 160 315 315 25 32 63 10016 – – – – – – – – –6 – – – – – – – – –100 125 125 160 315 315 25 32 63 100
K – – – – –
K
K
– – –
K – – – –– – – –
K – – –
K – – – – –
K
K
K – – – – –
K
K
K – – – – –
K
K
K
K
K – –
K
K
K
K
K – – – –
K
K
– – – – – – – –
– – – – – –
K –– – – – – – – –
� – – – – –
K
K
K
K –
K
K –
K
K
– – – – – –
K
K
Moeller HPL0211-2001/2002
T Rotary SwitchesSystem Overview
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/006
T0, T3, T5B, T5 On-Off switches
T0, T3, T5B, T5 control switches
10
9
8
7
7
6
5
4
3
2
1
6
8
9
10
10
1
2
3
4
99
10
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/007Moeller HPL0211-2001/2002
T Rotary SwitchesSystem Overview
Service distribution board mounting (.../IVS)
1
Front IP30For snap fitting to EN 50 022 top-hat railFlush mounting– service distribution boards: up to
3 contact units (45 mm mounting depth)– control panels: up to 11 contact units
a Page 07/019
Rear mounting (.../Z) 2Front IP65Secured by screw fixing or snap fitting(T0 or T3)For snap fitting to EN 50 022 top-hat railCoupling drive in door or coverConnection from the front
a Page 07/019
Rear mounting main switches(.../V/SVB)
2
Front IP65To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 12contacts for T3With door interlock in I (On) position
a Page 07/013
Flush mounting (.../E) 3Front IP65Fitting and connection from the rearTerminal:Pozidriv plus-minus screwFinger and back-of-hand proofType T8 with extension terminals as standard
a Page 07/018
Flush mounting main switches (.../EA/SVB)
3
Front IP65To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 12contacts for T3N terminal and PE terminal
a Page 07/012
Centre mounting (.../EZ) 3Front IP65Mounting in ∅ 22.3 fixing hole to IEC/EN 60 947-5-1Centre fixing permits installation by one fitter
a Page 07/019
Surface mounting (.../I...) 4IP65 With PE terminalEnclosures designed for metric cable glands to EN 50 262
a Page 07/019
Surface mounting main switches(.../I...)
4
IP65 To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 10contacts for T30 (Off) position lockable using up to 3 padlocksEnclosures designed for metric cable glands to EN 50 262With PE terminal
a Page 07/013
Safety switches (.../I...) 5IP65 With PE terminalWith cover fixing in the 0 (Off) position0 (Off) position lockable using up to 3 padlocksEnclosures designed for metric cable glands to EN 50 262With “Safety Switch” labelColour: orangeFor Switzerland: comply with the Swiss Accident Insurance Institute Directive
a Page 07/024
Main switch (assembly kit)for use as Emergency-Stop device
6
To IEC/EN 60 204-1
With red rotary handle and yellow locking collar
Lockable in the 0 (Off) position
a Page 07/062
Main switch (assembly kit) 7Black rotary handle and locking collarLockable in the 0 (Off) position
a Page 07/062
Thumb-grip for use in Emergency-Stop devices
8
To IEC/EN 60 204-1
Red thumb-grip with yellow front plate
a Page 07/062
Thumb-grip 9Black thumb-grip with front plate
a Page 07/062
Coupling drive 10Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../ZFor retrofit conversion of T5(B)-.../Eflush mounting switches to rear mounting form Spare part for T5(B)-.../Z
a Page 07/066
Moeller HPL0211-2001/2002
P Switch-DisconnectorsSystem Overview
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/008
P1, P3 On-Off switches
11
10
10
9
9
8
7
7
5
3
2
1
4
41
68
11
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/009Moeller HPL0211-2001/2002
P Switch-DisconnectorsSystem Overview
Service distribution board mounting (.../IVS)
1
Front IP30Fitting dimensions to DIN 43 880For snap fitting to EN 50 022 top-hat railSpace requirement P1, 3-pole: 3 space unitsP3, 3-pole: 4 space unitsP3-.../IVS can be locked in 0 (Off) position using the padlocking feature
a Page 07/019
Rear mounting (.../Z) 2Front IP65Secured by snap fitting or screw fixing
For snap fitting to EN 50 022 top-hat railCoupling drive in door or coverConnection from the front2 add-on modules can be fitted (or retrofitted)
a Page 07/019
Rear mounting main switches(.../V/SVB)
2
Front IP65To IEC/EN 60 204 andIEC/EN 60 947-3With door interlock in I (On) position Maintenance key for commissioning or fault tracing 0 (Off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted)
a Page 07/013
Flush mounting (.../E) 3Front IP65Fitting and connection from the rearTerminal:Pozidriv plus-minus screwFinger and back-of-hand proof2 add-on modules can be fitted (or retrofitted)
a Page 07/018
Flush mounting main switches (.../EA/SVB)
3
Front IP65To IEC/EN 60 204 andIEC/EN 60 947-3N terminal and PE terminal0 (Off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted)
a Page 07/012
Centre mounting (.../EZ) 3Front IP65Mounting in ∅ 22.3 fixing hole to IEC/EN 60 947-5-1Centre fixing permits installation by one fitter
a Page 07/019
Add-on modules 4Switched neutral(early-make contact)HI 11 auxiliary contact = 1 make contact + 1 break contact
Finger-proofAuxiliary make contact: always connected as load-shedding contact (late-make, early-break)
a Page 07/064
Surface mounting (.../I...) 5IP65 With PE terminalAdd-on modules for retrofitting:P1: + 1, P3: + 2Enclosures designed for metric cable glands to EN 50 262
a Page 07/019
Surface mounting main switches(.../I...)
5
IP65 With PE terminalTo IEC/EN 60 204 andIEC/EN 60 947-30 (Off) position lockable using up to 3 padlocksAdd-on modules for retrofitting: P1: + 1, P3: + 2Enclosures designed for metric cable glands to EN 50 262
a Page 07/013
Safety switches (.../I...-SI) 6IP65 With PE terminalWith cover fixing in the 0 (Off) position0 (Off) position lockable using up to 3 padlocksWith “Safety Switch” labelColour: orangeEnclosures designed for metric cable glands to EN 50 262For Switzerland: comply with the Swiss Accident Insurance Institute Directive
a Page 07/024
Main switch (assembly kit)for use as Emergency-Stop device
7
To IEC/EN 60 204-1With red rotary handle and yellow locking collarLockable in the 0 (Off) position
a Page 07/062
Main switch (assembly kit) 8Black rotary handle and locking collarLockable in the 0 (Off) position
a Page 07/062
Thumb-grip for use in Emergency-Stop devices
9
To IEC/EN 60 204-1Red thumb-grip with yellow front plate
a Page 07/062
Thumb-grip 10Black thumb-grip with front plate
a Page 07/062
Coupling drive 11Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../ZFor retrofit conversion of T5(B)-.../Eflush mounting switches to rear mounting form Spare part for T5(B)-.../Z
a Page 07/066
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsKey to Type References, Modular System
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/010
Using the modular system to convert the mounting form
Using the modular system to convert the mounting form of T5(B)
Rotary switches are suitable for many different switching and control functions, e.g. as On-Off switches, main switches, main circuit/auxiliary circuit control switches, instrument selector switches.
The switches consist of a handle, basic switch and mounting accessories.
The contact chamber (contact unit) contains1 or 2 contacts.
Our “T Rotary Switches” catalogue, K115, shows more than 800 often used standard contact sequences (available on request).
On the following Pages, you will find a selection of the standard contact sequences we offer.
T rotary switches and P switch-disconnectors are manufactured without PCB, CFC, asbestos or silicon. The contacts are cadmium-free.
The CI-K insulated enclosures do not contain silicon
Technical Data for CI-K small enclosures:
a See Instal-lation Equipment Catalogue, HPL0212-2000GB
T0 and T3 rotary switches
Key to type references
T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑ ↑
Switch sizeT0 or T3
Number of contact chambers = contact units
Contact sequence number
Mounting form
a Page 07/004Front plate Type(if different from list Type)
a Page 07/054
Accessories
a Page 07/056
T5(B) rotary switches
Key to type references
T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑ ↑
Switch sizeT5(B)
Number of contact chambers = contact units
Contact sequence number
Mounting form
a Page 07/004Front plate Type(if different from list Type)
a Page 07/054
Accessories
a Page 07/054
Notes Types preceded by “+...” are additions to thebasic Type and cannot be ordered separately.
1) Includes shaft
CI-K1-T0CI-K2-T3
T0-.../I11)
T3-.../I21)T0.../IVS1)
T0(3).../E
T0(3).../EZ
EZ-T0 V/EA/SVB-T0 T0(3).../XZ IVS-T0 DE-T0
T0(3).../Z1)
V/EA/SVB-T0
T0-1-(T3-1-).../V/SVB...T0-4-(T3-1-).../V/SVB
T0-1-(T3-1-).../EA/SVB...T0-4-(T3-6-).../EA/SVB
CI-K4-T5BCI-K5-T5
DE-P3V/EA/SVB-T5T5(B)...E
T5(B).../EA/SVB T5(B).../Z
V/EA/SVB-T5
T5(B).../V/SVB
T5B-.../I4T5-.../I5
SVB-P3
T5B-.../I4/SVBT5-.../I5/SVB
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/011Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsKey to Type References, Modular System
The modular system offers add-on functions
P1 and P3 switch-disconnectors
Key to type references
P . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑
Switch sizeP1 or P3
Rated uninterrupted current Mounting form
a Page 07/005Type suffix(if required)
Accessories
a Page 07/056
TM mini rotary switchesThe TM rotary switch requires very little space due to its exceptionally small dimensions. It is particularly well suited for switching the low voltages and low currents which occur in electronic control panels, for example. The gold-plated contacts provide extra reli-ability and safety.
TM mini rotary switches have consecutive terminal markings, beginning with 1.
Key to type references
TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑
Number of contact chambers = contact units
Contact sequence number
Mounting form
a Page 07/074Accessories
a Page 07/083
Circuit diagrams
on Pages 07/012 – 053 and 07/074 – 082
Example:
(see also Ordering Example on Page 07/111)Switch position 1:Contact 1 – 2 open,Contact 3 – 4 closed.
Switching from 1 to 2:Contact 1 – 2 closes with early make,Contact 3 – 4 opens with late break.
Switching from 2 to 3:Contact 1 – 2 opens briefly.
Switching from 3 to 4:Contact 1 – 2 remains closed,Automatic return from 4 to 3.
N-P...E orN-P...Z
HI 11-P1/P3E orHI 11-P1/P3Z
3-pole basic unit.../E oder .../Z
Switched neutralCan be fitted left or right(for P1.../I: left only)
Auxiliary contactCan be fitted leftor right(for P1.../I: left only)
Terminal shroudcan be fitted attop and bottom
N + PE terminals alsoas cover interlockon .../Z-switches.
H-P... UV-P...
1
2
3
4Terminal marking
Link
1
2
3
4
0
1
2
Contact open
Contact closed
Switch position
0
1
2
3
4
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches
For use as Emergency-Stop device1) Without Emergency-Stop function2)
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingFront IP65
Surface mounting 3)
IP65
Rear mountingFront IP65
Flush mountingFront IP65
Surface mounting 3) IP65
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price ListM M B kW kW kW A
Main switches1 0 0 1 1.3 – 20 T0-1-8200/... EA/SVB
053110I1/SVB207145
V/SVB057856
EA/SVB-SW055483
I1/SVB-SW207146
V/SVB-SW060229
1.8 3.6 – 32 T3-1-8200/... EA/SVB066576
I2/SVB207200
V/SVB007255
EA/SVB-SW068949
I2/SVB-SW207201
V/SVB-SW004882
5 7.3 – 63 T5B-1-8200/... EA/SVB094279
I4/SVB207240
V/SVB094273
EA/SVB-SW094278
I4/SVB-SW207241
V/SVB-SW094272
7.3 12.3 – 100 T5-1-8200/... EA/SVB097224
I5/SVB207275
V/SVB097222
EA/SVB-SW097223
I5/SVB-SW207276
V/SVB-SW097221
2 0 0 2.2 2.2 – 20 T0-1-102/... EA/SVB091078
I1/SVB207143
V/SVB095824
EA/SVB-SW093451
I1/SVB-SW207144
V/SVB-SW022330
3 5.5 – 32 T3-1-102/... EA/SVB014374
I2/SVB207198
V/SVB019120
EA/SVB-SW016747
I2/SVB-SW207199
V/SVB-SW021493
7.5 11 – 63 T5B-1-102/... EA/SVB094469
I4/SVB207238
V/SVB094463
EA/SVB-SW094468
I4/SVB-SW207239
V/SVB-SW094462
11 18.5 – 100 T5-1-102/... EA/SVB098808
I5/SVB207273
V/SVB098806
EA/SVB-SW098807
I5/SVB-SW207274
V/SVB-SW098805
3 0 0 3 4 4 20 T0-2-1/... EA/SVB038873
I1/SVB207147
V/SVB043619
EA/SVB-SW041246
I1/SVB-SW207148
V/SVB-SW045992
5.5 7.5 7.5 25 P1-25/... EA/SVB041097
I2/SVB207293
V/SVB055335
EA/SVB-SW048365
I2/SVB-SW207294
V/SVB-SW050738
7.5 13 15 32 P1-32/... EA/SVB081438
I2/SVB207314
V/SVB095676
EA/SVB-SW053111
I2/SVB-SW207315
V/SVB-SW055484
15 30 30 63 P3-63/... EA/SVB031607
I4/SVB207343
V/SVB048218
EA/SVB-SW057857
I4/SVB-SW207344
V/SVB-SW060230
22 37 37 100 P3-100/... EA/SVB074320
I5/SVB207373
V/SVB088558
EA/SVB-SW062603
I5/SVB-SW207374
V/SVB-SW064976
22 37 22 125 T6-2/... EA/SVB012679
– V/SVB015052
EA/SVB-SW067349
– V/SVB-SW069722
3+N 0 0 3 4 4 20 T0-2-8900/... EA/SVB207400
I1/SVB207151
V/SVB207405
EA/SVB-SW207401
I1/SVB-SW207152
V/SVB-SW207406
5.5 7.5 7.5 25 P1-25/... EA/SVB/N081587
I2/SVB/N207298
V/SVB/N086333
EA/SVB-SW/N083960
I2/SVB-SW/N207296
V/SVB-SW/N088706
7.5 13 15 32 P1-32/... EA/SVB/N091079
I2/SVB/N207319
V/SVB/N095825
EA/SVB-SW/N093452
I2/SVB-SW/N207317
V/SVB-SW/N098198
15 30 30 63 P3-63/... EA/SVB/N010398
I4/SVB/N207349
V/SVB/N015144
EA/SVB-SW/N012771
I4/SVB-SW/N207346
V/SVB-SW/N017517
22 37 37 100 P3-100/... EA/SVB/N019890
I5/SVB/N207379
V/SVB/N024636
EA/SVB-SW/N022263
I5/SVB-SW/N207376
V/SVB-SW/N027009
6 0 0 3 4 4 20 T0-3-8342/... EA/SVB029382
I1/SVB207159
V/SVB034128
EA/SVB-SW031755
I1/SVB-SW207160
V/SVB-SW036501
6.5 12 15 32 T3-3-8342/... EA/SVB071326
I2/SVB207208
V/SVB076072
EA/SVB-SW073699
I2/SVB-SW207209
V/SVB-SW078445
15 22 22 63 T5B-3-8342/... EA/SVB092308
I4/SVB207242
V/SVB092300
EA/SVB-SW092307
I4/SVB-SW207243
V/SVB-SW092299
18.5 30 30 100 T5-3-8342/... EA/SVB096383
I5/SVB207279
V/SVB096381
EA/SVB-SW096382
I5/SVB-SW207280
V/SVB-SW096380
8 0 0 3 4 4 20 T0-4-8344/... EA/SVB008267
I1/SVB207163
V/SVB014007
EA/SVB-SW008268
I1/SVB-SW207164
V/SVB-SW008272
6.5 12 15 32 T3-4-8344/... EA/SVB008964
I2/SVB207212
V/SVB020598
EA/SVB-SW008965
I2/SVB-SW207213
V/SVB-SW008967
15 22 22 63 T5B-4-8344/... EA/SVB092062
I4/SVB207248
V/SVB092056
EA/SVB-SW092061
I4/SVB-SW207249
V/SVB-SW092055
22 30 30 1004) T5-4-8344/... EA/SVB095961
I5/SVB207283
V/SVB095959
EA/SVB-SW095960
I5/SVB-SW207284
V/SVB-SW095958
Standard pack: 1 off Standard pack: 1 off
Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position3) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
4) T5-4-8344/I5... max. 95 A
FS 908
ON
OFF
1
2
1
2
3
4
1 3 5
2 4 6
2
1 3
4
5
6
7
8
2
1 3
4
5
6
N
N
2
1 3
4
5
6
7
8
9
10 12
11
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
07/012 07/013
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches with Auxiliary Contacts, Maintenance Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches with Auxiliary Contacts, Maintenance Switches
For use as Emergency-Stop device1) Without Emergency-Stop function2)
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingFront IP65
Surface mounting 4) IP65
Rear mountingFront IP65
Flush mountingFront IP65
Surface mounting 4) IP65
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price ListM M B kW kW kW A
Main switches with auxiliary contacts3 1 0 3 4 4 20 T0-2-15679/... EA/SVB
081588I1/SVB207149
V/SVB086334
EA/SVB-SW083961
I1/SVB-SW207150
V/SVB-SW088707
3 1 1 5.5 7.5 7.5 25 P1-25/... EA/SVB/HI11091080
I2/SVB/HI11207297
V/SVB/HI11095826
EA/SVB-SW/HI11070194
I2/SVB-SW/HI11207295
V/SVB-SW/HI11098199
7.5 13 15 32 P1-32/... EA/SVB/HI11072567
I2/SVB/HI11207318
V/SVB/HI11015145
EA/SVB-SW/HI11012772
I2/SVB-SW/HI11207316
V/SVB-SW/HI11017518
15 30 30 63 P3-63/... EA/SVB/HI11019891
I4/SVB/HI11207348
V/SVB/HI11024637
EA/SVB-SW/HI11022264
I4/SVB-SW/HI11207345
V/SVB-SW/HI11027010
22 37 37 100 P3-100/... EA/SVB/HI11029383
I5/SVB/HI11207378
V/SVB/HI11034129
EA/SVB-SW/HI11031756
I5/SVB-SW/HI11207375
V/SVB-SW/HI11036502
3 2 1 3 4 4 20 T0-3-15683/... EA/SVB015571
I1/SVB207157
V/SVB015634
EA/SVB-SW015600
I1/SVB-SW207158
V/SVB-SW015664
6.5 12 15 32 T3-3-15683/... EA/SVB040478
I2/SVB207206
V/SVB045224
EA/SVB-SW042851
I2/SVB-SW207207
V/SVB-SW047597
3+N 1 1 3 4 4 20 T0-3-15680/... EA/SVB038875
I1/SVB207153
V/SVB043621
EA/SVB-SW041248
I1/SVB-SW207154
V/SVB-SW045994
6.5 12 15 32 T3-3-15680/... EA/SVB012002
I2/SVB207202
V/SVB016748
EA/SVB-SW014375
I2/SVB-SW207203
V/SVB-SW019121
3+N 1 1 5.5 7.5 7.5 25 P1-25/... EA/SVB/N/HI11048367
– V/SVB/N/HI11053113
EA/SVB-SW/N/HI11050740
– V/SVB-SW/N/HI11055486
7.5 13 15 32 P1-32/... EA/SVB/N/HI11057859
– V/SVB/N/HI11062605
EA/SVB-SW/N/HI11060232
– V/SVB-SW/N/HI11064978
15 30 30 63 P3-63/... EA/SVB/N/HI11067351
I4/SVB/N/HI11207350
V/SVB/N/HI11072097
EA/SVB-SW/N/HI11069724
I4/SVB-SW/N/HI11207347
V/SVB-SW/N/HI11074470
22 37 37 100 P3-100/... EA/SVB/N/HI11076843
I5/SVB/N/HI11207380
V/SVB/N/HI11081589
EA/SVB-SW/N/HI11079216
I5/SVB-SW/N/HI11207377
V/SVB-SW/N/HI11083962
3+N 1 1 3 4 4 20 T0-3-15681/... EA/SVB086335
I1/SVB207155
V/SVB091081
EA/SVB-SW088708
I1/SVB-SW207156
V/SVB-SW093454
6.5 12 15 32 T3-3-15681/... EA/SVB026240
I2/SVB207204
V/SVB030986
EA/SVB-SW028613
I2/SVB-SW207205
V/SVB-SW033359
15 22 22 63 T5B-3-8901/... EA/SVB207420
I4/SVB207244
V/SVB207422
EA/SVB-SW207421
I4/SVB-SW207245
V/SVB-SW207423
18.5 30 30 100 T5-3-8901/... EA/SVB207408
I5/SVB207277
V/SVB207410
EA/SVB-SW207409
I5/SVB-SW207278
V/SVB-SW207411
6 1 1 3 4 4 20 T0-4-15682/... EA/SVB019892
I1/SVB207161
V/SVB024638
EA/SVB-SW022265
I1/SVB-SW207162
V/SVB-SW027011
6.5 12 15 32 T3-4-15682/... EA/SVB054716
I2/SVB207210
V/SVB059462
EA/SVB-SW057089
I2/SVB-SW207211
V/SVB-SW061835
15 22 22 63 T5B-4-15682/... EA/SVB207425
I4/SVB207246
V/SVB207427
EA/SVB-SW207426
I4/SVB-SW207247
V/SVB-SW207428
18.5 30 30 100 T5-4-15682/... EA/SVB207413
I5/SVB207281
V/SVB207415
EA/SVB-SW207414
I5/SVB-SW207282
V/SVB-SW207416
6 1 1 22 42 22 160 T6-160-6/... – I45/SVB/HI115)
201448V/SVB/HI11200619
– I45/SVB-SW/HI115)
201447V/SVB-SW/HI11200127
37 55 37 3153) T8-3-8342/... – I48/SVB/HI116)
201450V/SVB/HI11200620
– I48/SVB-SW/HI116)
201449V/SVB-SW/HI11200128
Standard pack: 1 off Standard pack: 1 off
Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position3) Enclosed version, up to 275 A4) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/0705) Enclosures without flanges, with K95/1N/BR
6) With KS4-CI and K150/1/BR
FS 908
ON
OFF
2
1 3
4
5
6
7
8
2
1 3
4
5
6
13
14 22
21
L2 L3L1
2
1 3
4
5
6
7
8
9
10 12
11
L2 L3 NL1
2
1 3
4
5
6
7
8
9
10 12
11
N
2
1 3
4
5
6
13 21
14 22
L2 L3
N
L1
L2 L3 NL1
2
1 3
4
5
6
7
8
9
10 12
11
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
2
1 3
4
5
6
7
8
9
10 12
11 13
14 22
21
07/014 07/015
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches in Sheet Steel Enclosures
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches in Sheet Steel Enclosures
For use as Emergency-Stop device1)
Without Emergency-Stop function2)
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Surface mountingIP65
Surface mountingIP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price ListM M B kW kW kW A
Main switches in sheet steel enclosures3 0 0 3 4 4 20 T0-2-1/... ST/SVB
025528ST/SVB-SW201713
5.5 7.5 7.5 25 P1-25/... ST/SVB025523
ST/SVB-SW201714
7.5 13 15 32 P1-32/... ST/SVB025522
ST/SVB-SW201715
15 30 30 63 P3-63/... ST/SVB025521
ST/SVB-SW201716
22 37 37 100 P3-100/... ST/SVB025520
ST/SVB-SW201717
Main switches with auxiliary contacts6 1 1 3 4 4 20 T0-4-15682/... ST/SVB
025527ST/SVB-SW201718
6.5 12 15 32 T3-4-15682/... ST/SVB025526
ST/SVB-SW201719
15 22 22 63 T5B-4-15682/... ST/SVB215328
ST/SVB-SW215329
18.5 30 30 100 T5-4-15682/... ST/SVB215330
ST/SVB-SW215331
Standard pack: 1 off Standard pack: 1 off
Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position
FS 908
ON
OFF
1 3 5
2 4 6
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
07/016 07/017
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M M B kW kW kW A
On-Off switches1)
1 0 0 1 1.3 – 20 T0-1-8200/... E067352
EZ069725
I1207074
IVS074471
Z076844
1.8 3.6 – 32 T3-1-8200/... E064208
EZ066581
I2207167
– Z071327
5 7.3 – 63 T5B-1-8200/... E094281
– I4207218
– Z094270
7.3 12.3 – 100 T5-1-8200/... E097226
– I5207264
– Z097219
2 0 0 2.2 2.2 – 20 T0-1-102/... E088709
EZ091082
I1207061
IVS015147
Z095828
3 5.5 – 32 T3-1-102/... E076073
EZ078446
I2207165
– Z083192
7.5 11 – 63 T5B-1-102/... E094471
– I4207215
– Z094460
11 18.5 – 100 T5-1-102/... E098810
– I5207262
– Z098803
3 0 0 3 4 4 20 T0-2-1/... E024639
EZ027012
I1207081
IVS031758
Z036504
5.5 7.5 7.5 25 P1-25/... E038724
EZ041250
I2207299
IVS052962
Z057708
7.5 13 15 32 P1-32/... E079065
EZ048369
I2207320
IVS093303
Z098049
15 30 30 63 P3-63/... E026861
– I4207356
IVS041099
Z050591
22 37 37 100 P3-100/... E067201
– I5207381
IVS081439
Z090931
22 37 22 125 T6-2/... E098106
– – – –
3+N 0 0 3 4 4 20 T0-2-8900/... E207398
EZ207402
I1207109
IVS207403
Z207407
5.5 7.5 7.5 25 P1-25/... E/N076845
EZ/N079218
I2/N207303
IVS/N083964
Z/N088710
7.5 13 15 32 P1-32/... E/N093456
EZ/N095829
I2/N207324
IVS/N010402
Z/N015148
15 30 30 63 P3-63/... E/N019894
– I4/N207360
IVS/N022267
Z/N027013
22 37 37 100 P3-100/... E/N031759
– I5/N207385
IVS/N034132
Z/N038878
6 0 0 3 4 4 20 T0-3-8342/... E043624
EZ045997
I1207131
IVS050743
Z055489
6.5 12 15 32 T3-3-8342/... E045225
EZ047598
I2207187
– Z052344
15 22 22 63 T5B-3-8342/... E092310
– I4207226
– Z092297
18.5 30 30 100 T5-3-8342/... E096385
– I5207267
– Z096378
8 0 0 3 4 4 20 T0-4-8344/... E014000
EZ014002
I1207139
IVS014006
Z014009
6.5 12 – 32 T3-4-8344/... E020593
EZ020595
I2207194
– Z020600
15 22 22 63 T5B-4-8344/... E092064
– I4207233
– Z092053
22 30 30 1003) T5-4-8344/... E095963
– I5207272
– Z095956
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/0703) T5-4-8344/I5 up to 95 A
FS 908
ON
OFF
1
2
1
2
3
4
1 3 5
2 4 6
2
1 3
4
5
6
7
8
2
1 3
4
5
6
N
N2
1 3
4
5
6
N
N
2
1 3
4
5
6
7
8
9
10 12
11
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
07/018 07/019
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches with Auxiliary Contacts
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches with Auxiliary Contacts
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M M B kW kW kW A
On-Off switches with auxiliary contacts1)
3 1 0 3 4 4 20 T0-2-15679/... E029387
EZ031760
I1207094
IVS036506
Z041252
3 1 1 5.5 7.5 7.5 25 P1-25/... E/HI11045998
EZ/HI11048371
I2/HI11207302
IVS/HI11053117
Z/HI11057863
7.5 13 15 32 P1-32/... E/HI11062609
EZ/HI11064982
I2/HI11207323
IVS/HI11069728
Z/HI11074474
15 30 30 63 P3-63/... E/HI11079220
– I4/HI11207359
IVS/HI11081593
Z/HI11086339
22 37 37 100 P3-100/... E/HI11069574
– I5/HI11207384
IVS/HI11091085
Z/HI11093304
3 2 1 3 4 4 20 T0-3-15683/... E016619
EZ016658
I1207118
IVS016722
Z016843
6.5 12 15 32 T3-3-15683/... E014377
EZ040480
I2207182
– Z019123
6 1 1 3 4 4 20 T0-4-15682/... E010405
EZ012778
I1207135
IVS017524
Z022270
6.5 12 15 32 T3-4-15682/... E023869
EZ026242
I2207190
– Z030988
15 22 22 63 T5B-4-15682/... E207424
– I4207229
– Z207429
18.5 30 30 100 T5-4-15682/... E207412
– I5207269
– Z207417
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
FS 908
ON
OFF
2
1 3
4
5
6
7
8
2
1 3
4
5
6
13
14 22
21
L2 L3L1
2
1 3
4
5
6
7
8
9
10 12
11
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
07/020 07/021
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsOn-Off Switches
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M M B kW kW kW A
On-Off switches for use as Emergency-Stop devices1)
1 0 0 1 1.3 – 20 T0-1-8200/... E-RT009474
I1-RT207075
IVS-RT081956
1.8 3.6 – 32 T3-1-8200/... E-RT017025
I2-RT207168
–
5 7.3 – 63 T5B-1-8200/... E-RT094280
I4-RT207219
–
7.3 12.3 – 100 T5-1-8200/... E-RT097225
I5-RT207265
–
2 0 0 2.2 2.2 – 20 T0-1-102/... E-RT009046
I1-RT207062
IVS-RT079583
3 5.5 – 32 T3-1-102/... E-RT016318
I2-RT207166
–
7.5 11 – 63 T5B-1-102/... E-RT094470
I4-RT207216
–
11 18.5 – 100 T5-1-102/... E-RT098809
I5-RT207263
–
3 0 0 3 4 4 20 T0-2-1/... E-RT011082
I1-RT207082
IVS-RT084329
5.5 7.5 7.5 25 P1-25/... E-RT002388
I2-RT207300
IVS-RT013140
7.5 13 15 32 P1-32/... E-RT003197
I2-RT207321
IVS-RT022632
15 30 30 63 P3-63/... E-RT005743
I4-RT207357
IVS-RT045845
22 37 37 100 P3-100/... E-RT007189
I5-RT207382
IVS-RT086185
3+N 0 0 3 4 4 20 T0-2-8900/... E-RT207399
I1-RT207110
IVS-RT207404
5.5 7.5 7.5 25 P1-25/... E-RT/N002425
I2-RT/N207301
IVS-RT/N017886
7.5 13 15 32 P1-32/... E-RT/N004555
I2-RT/N207322
IVS-RT/N027378
15 30 30 63 P3-63/... E-RT/N007136
I4-RT/N207358
IVS-RT/N041616
22 37 37 100 P3-100/... E-RT/N007280
I5-RT/N207383
IVS-RT/N034497
Standard pack: 1 off Standard pack: 1 off
Notes 1) To IEC/EN 60 204-1; with red thumb-grip and yellow front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
FS 908 GE
1
0
1
2
1
2
3
4
1 3 5
2 4 6
2
1 3
4
5
6
7
8
2
1 3
4
5
6
N
N
07/022 07/023
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsSafety Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsSafety Switches
For use as Emergency-Stop device1)
Without Emergency-Stop function2)
Circuit diagram Front plate no.
Main contacts
Auxiliary contacts
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Surface mountingIP65
Surface mounting 3) IP65
Notes
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu
TypeArticle no.
PriceSee Price List
TypeArticle no.
PriceSee Price ListM M B kW kW kW A
Safety switches3 0 0 5.5 7.5 7.5 25 P1-25/I2-SI
207308P1-25/I2-SI-SW207309
Padlocking feature with captive cover fixing
With “Safety Switch” warning plate(other languages on request)Neutral conductor or HI11 auxiliary contact can also be retrofitted to P1 and P3 safety switches
a Page 07/065
For general information onSafety Switches
a Page 07/109For switches in accordance with the Swiss Accident Insurance Institute Directive, please contact Moeller Switzerland
7.5 13 15 32 P1-32/I2-SI207329
P1-32/I2-SI-SW207330
3+N 0 0 5.5 7.5 7.5 25 P1-25/I2-SI/N207312
P1-25/I2-SI/N-SW207313
7.5 13 15 32 P1-32/I2-SI/N207333
P1-32/I2-SI/N-SW207334
With auxiliary contacts 3 1 1 5.5 7.5 7.5 25 P1-25/I2-SI/HI11207310
P1-25/I2-SI/HI11-SW207311
7.5 13 15 32 P1-32/I2-SI/HI11207331
P1-32/I2-SI/HI11-SW207332
3 0 0 15 30 30 63 P3-63/I4-SI207361
P3-63/I4-SI-SW207362
22 37 37 100 P3-100/I5-SI207386
P3-100/I5-SI-SW207387
3+N 0 0 15 30 30 63 P3-63/I4-SI/N207365
P3-63/I4-SI/N-SW207366
22 37 37 100 P3-100/I5-SI/N207390
P3-100/I5-SI/N-SW207391
With auxiliary contacts 3 1 1 15 30 30 63 P3-63/I4-SI/HI11207363
P3-63/I4-SI/HI11-SW207364
22 37 37 100 P3-100/I5-SI/HI11207388
P3-100/I5-SI/HI11-SW207389
6 0 0 15 22 22 63 T5B-3-8342/I4-SI207250
T5B-3-8342/I4-SI-SW207251
No contacts can be retrofitted to T... rotary switches.
18.5 30 30 100 T5-3-8342/I5-SI207447
T5-3-8342/I5-SI-SW207448
With auxiliary contacts 6 1 1 15 22 22 63 T5B-4-15682/I4-SI207254
T5B-4-15682/I4-SI-SW207255
18.5 30 30 100 T5-4-15682/I5-SI207285
T5-4-15682/I5-SI-SW207286
With auxiliary contacts 6 2 0 15 22 22 63 T5B-4-8903/I4-SI207258
T5B-4-8903/I4-SI-SW207259
18.5 30 30 100 T5-4-8903/I5-SI207289
T5-4-8903/I5-SI-SW207290
Standard pack: 1 off Standard pack: 1 off
Notes 1) To IEC/EN 60 204 Part 1; with red rotary handle and yellow locking collar, lockable in 0 (Off) positionwith cover interlock
2) With black rotary handle and locking collar, lockable in 0 (Off) position with cover interlock3) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
FS 908
ON
OFF
1 3 5
2 4 6
2
1 3
4
5
6
N
N
2
1 3
4
5
6
13
14 22
21
1 3 5
2 4 6
2
1 3
4
5
6
N
N
2
1 3
4
5
6
13
14 22
21
2
1 3
4
5
6
7
8
9
10 12
11
2
1 3
4
5
6
7
8
9
10 12
11 13
14 22
21
2
1 3
4
5
6
7
8
9
10 12
11 13
14 16
15
07/024 07/025
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Circuit diagram Front plate no.
Max. three-phasemotor rating (per set of 3 contacts)50 – 60 Hz
Rated unin-terrupted current
Iu
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M kW kW kW A
Changeover switches with 0 (Off) position 1)
Group switches, mains transfer switches1 1 1.3 – 20 T0-1-8210/... E
012742EZ048337
I1207076
IVS074440
Z019862
1.8 3.6 – 32 T3-1-8210/... E054718
EZ003072
I2207169
– Z057091
5 7.3 – 63 T5B-1-8210/... E094261
– I4207432
– Z094258
2 2.2 2.2 – 20 T0-2-8211/... E022234
EZ053083
I1207102
IVS076813
Z029354
3 5.5 – 32 T3-2-8211/... E061837
EZ003075
I2207178
– Z064210
7.5 11 – 63 T5B-2-8211/... E093094
– I4207220
– Z093082
3 3 4 4 20 T0-3-8212/... E029353
EZ057829
I1207123
IVS079186
Z036473
6.5 12 15 32 T3-3-8212/... E068956
EZ003080
I2207183
– Z071329
15 22 22 63 T5B-3-8212/... E092386
– I4207223
– Z092383
18.5 30 30 100 T5-3-8212/... E096466
– I5207266
– Z096464
3 22 37 22 125 T6-3-8212/... E/HI12214781
– – – –
37 55 37 315 T8-3-8212/... E/HI12214782
– – – –
4 3 4 4 20 T0-4-8213/... E031726
EZ062575
I1207136
IVS081559
Z043592
6.5 12 15 32 T3-4-8213/... E076075
EZ003079
I2207191
– Z078448
15 22 22 63 T5B-4-8213/... E092112
– I4207230
– Z092109
18.5 30 30 100 T5-4-8213/... E096014
– I5207270
– Z096012
4 3 4 4 20 T0-4-8294/... E010371
EZ072069
I1207138
IVS043594
Z048347
6.5 12 15 32 T3-4-8294/... E002513
EZ001014
I2207193
– Z004886
15 22 22 63 T5B-4-8294/... E092084
– I4207232
– Z092081
18.5 30 22 100 T5-4-8294/... E095986
– I5207433
– Z095984
4 6.5 12 15 32 T3-4-8902/... E215222
EZ215223
I2215224
– Z215225
15 22 22 63 T5B-4-8902/... E207430
– I4207237
– Z207431
18.5 30 22 100 T5-4-8902/... E207418
– I5207214
– Z207419
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
201
2
1 3
4
FS 684
01 2
201
2
1 3
4
5
6
7
8
FS 684
01 2
201
2
1 3
4
5
6
7
8
9
10
11
12
FS 684
01 2
2
1 3
4
5
6
7
8
9
10
11
12
11
12
101
102
103
104
105
106
201
FS 684
01 2
201
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
FS 684
01 2
201
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
FS 953
0
1 2
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
Emergencysupply
0Mains
0
FS 161629
NETZNOT-
STROM
07/026 07/027
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Circuit diagram Front plate no.
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Iu
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M kW kW kW A
Changeover switches with 0 (Off) position1)
With spring-return from both directions to 01 1 1.3 – 20 T0-1-8214/... E
019863EZ076815
I1207077
IVS045967
Z050720
1.8 3.6 – 32 T3-1-8214/... E009632
EZ001073
I2207170
– Z012005
2 2.2 2.2 – 20 T0-2-8215/... E022236
EZ081561
I1207103
IVS048340
Z053093
3 5.5 – 32 T3-2-8215/... E016751
EZ001074
I2207179
– Z019124
3 3 4 4 20 T0-3-8216/... E024609
EZ086307
I1207434
IVS050713
Z055466
6.5 12 15 32 T3-3-8216/... E023870
EZ001077
I2207184
– Z026243
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
FS 4011
01 2
2
10
2
1 3
4
102
2
1 3
4
5
6
7
8
102
2
1 3
4
5
6
7
8
9
10
11
12
07/028 07/029
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Changeover Switches
Circuit diagram Front plate no.
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Iu
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M kW kW kW A
Changeover switches without 0 (Off) position1)
Changeover switches1 1.1 1.3 – 20 T0-1-8220/... E
031728EZ095799
I1207078
IVS055459
Z086312
1.8 3.6 – 32 T3-1-8220/... E038108
EZ001018
I2207171
– Z040481
2 2.2 2.2 – 20 T0-2-8221/... E038847
EZ010372
I1207104
IVS057832
Z074450
3 5.5 – 32 T3-2-8221/... E045227
EZ001025
I2207180
– Z047600
7.5 11 – 63 T5B-2-8221/... E093047
– I4207221
– Z093044
3 3 4 4 20 T0-3-8222/... E048339
EZ015118
I1207124
IVS060205
Z088686
6.5 12 15 32 T3-3-8222/... E052346
EZ001069
I2207185
– Z057092
15 22 22 63 T5B-3-8222/... E092378
– I4207224
– Z092375
4 3 4 4 20 T0-4-8223/... E050712
EZ019864
I1207137
IVS062578
Z086315
6.5 12 15 32 T3-4-8223/... E059465
EZ001070
I2207192
– Z061838
15 22 22 63 T5B-4-8223/... E092108
– I4207231
– Z092105
18.5 30 30 100 T5-4-8223/... E096010
– I5207271
– Z096008
5 3 4 4 20 T0-5-8369/... E060204
EZ024610
– IVS064951
Z098180
6.5 12 15 32 T3-5-8369/... E066584
EZ004503
I2207536
– Z068957
6 3 4 4 20 T0-6-8370/... E062577
EZ029356
– IVS067324
Z010380
6.5 12 15 32 T3-6-8370/... E073703
EZ004506
– – Z078449
8 3 4 4 20 T0-8-8372/... E064950
EZ034102
– IVS069697
Z012753
6.5 12 15 32 T3-8-8372/... E080822
EZ004508
– Z083195
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
1 2
FS 943
12
2
1 3
4
12
2
1 3
4
5
6
7
8
12
2
1 3
4
5
6
7
8
9
10
11
12
12
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
12
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
12
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23
12
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23 25 27 29 31
26 28 30 32
07/030 07/031
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Reversing Switches, Star-Delta Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Reversing Switches, Star-Delta Switches
Circuit diagram Front plate no.
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated unin-terrupted current
Iu
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles AC-3
220 V230 V240 V
380 V400 V440 V
660 V690 V
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M kW kW kW A
Reversing switches with 0 (Off) position1)
2 2.2 2.2 – 20 T0-2-8400/... E053079
EZ055452
I1207111
IVS060198
Z062571
3 5.5 – 32 T3-2-8400/... E073695
EZ000687
I2207181
– Z095060
7.5 11 – 63 T5B-2-8400/... E092918
– I4207222
– Z092915
3 3 4 4 20 T0-3-8401/... E091047
EZ093420
I1207132
IVS098166
Z010366
6.5 12 15 32 T3-3-8401/... E030992
EZ000694
I2207188
– Z035739
15 22 22 63 T5B-3-8401/... E092296
– I4207227
– Z092293
18.5 30 30 100 T5-3-8401/... E096376
– I5207268
– Z096374
With spring-return from both directions to 03 3 4 4 20 T0-3-8228/... E
015112EZ048334
I1207125
IVS062572
Z074437
6.5 12 15 32 T3-3-8228/... E002538
EZ000695
I2207186
– Z004911
15 22 22 63 T5B-3-8228/... E092374
– I4207225
– Z092371
Star-delta switches1)
3 4 5.5 5.5 20 T0-4-8410/... E024604
EZ053080
I1207140
IVS064945
Z083929
7.5 18.5 22 32 T3-4-8410/... E009657
EZ000721
I2207195
– Z012030
22 37 37 63 T5B-4-8410-/... E092052
– I4207234
– Z092049
Reversing Star-delta switches1)
Two-way switches3 4 5.5 5.5 20 T0-5-15876/... E
000893EZ000900
– IVS000902
Z000942
7.5 18.5 22 32 T3-5-15876/... E016776
EZ000797
I2207537
– Z019149
3 22 30 37 63 T5B-5-15876/... E214785
– – – Z214786
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
201
2
1 3
4
5
6
7
8
FS 684
01 2
201
1 3 5
2 4 6
7
8
9
10
FS 684
01 2
102
1 3 5
2 4 6
7
8
9
10
FS 4011
01 2
Y0
2
1 3
4
5
6
7
8
9
10
11 13 15
12 14 16
FS 635
Y0
Y
Y0
2
1 3
4
5
6
7
8
9 11 13 15 17 19
10 12 14 16 18 20
FS 638
Y0
Y
Y
Y0
2
1 3
4
5
6
7
8
9 11 13 15 17 19
10 12 14 16 18 20
FS 4017
Y0
Y
07/032 07/033
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Multi-Speed Switches, Reversing Multi-Speed Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Multi-Speed Switches, Reversing Multi-Speed Switches
Circuit diagram
Front plateno.
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated unin-terrupted current
Iu
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2)
IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
No. of poles
AC-3220 V230 V240 V
380 V400 V440 V
660 V690 V
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
M kW kW kW A
Multi-speed switches1)
Two-speed, non reversingFor 2 separate windings
3 3 4 4 20 T0-3-8451/... E038849
EZ083936
I1207133
IVS026985
Z043596
6.5 12 15 32 T3-3-8451/... E028641
EZ000956
I2207189
– Z031014
15 22 22 63 T5B-3-8451/... E092288
– I4207228
– Z092285
For one tapped winding3 3 4 4 20 T0-4-8440/... E
041222EZ088682
I1207141
IVS029358
Z048342
6.5 12 15 32 T3-4-8440/... E035760
EZ000959
I2207196
– Z038133
15 22 22 63 T5B-4-8440/... E092032
– I4207235
– Z092029
3 3 4 4 20 T0-4-8441/... E043595
EZ093428
I1207142
IVS031731
Z053088
6.5 12 15 32 T3-4-8441/... E042879
EZ000960
I2207197
– Z045252
15 22 22 63 T5B-4-8441/... E092028
– I4207236
– Z092025
Reversing multi-speed switches1)
Two-speed, two directionsFor one tapped winding
3 3 4 4 20 T0-6-15866/... E055460
EZ012747
– IVS036477
Z067326
6.5 12 15 32 T3-6-15866/... E054744
EZ000964
– – Z057117
3 15 22 22 63 T5B-7-15866/... E214788
– – – Z214789
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
210
2
1 3
4
5
6
7
8
9
10
11
12
FS 644
01
2
210
2
1 3
4
5
6
7
8
9 11 13 15
10 12 14 16
FS 644
01
2
201
2
1 3
4
5
6
7
8
9 11 13 15
10 12 14 16
FS 684
01 2
2
2101
2
1 3
4
5
6
7
8
9 11
10 12
13
14
15 17 19
16 18 20
21
22
23
24
FS 629
10
12 2
FS 441
10
12 2
07/034 07/035
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Step Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Step Switches
Circuit diagram Front plate no.
No. of poles
Steps Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Step switches1)
One contact closed per step(without overlap)With additional 0 (Off) position
1 2 T0-1-8240/... E034105
EZ043597
I1207079
IVS027076
Z060208
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
1 3 T0-2-8241/... E050716
EZ053089
I1207107
IVS057835
Z062581
1 4 T0-2-8242/... E067327
EZ069700
I1207108
IVS074446
Z076819
1 5 T0-3-8243/... E081565
EZ083938
I1207128
IVS088684
Z091057
1 6 T0-3-8244/... E095803
EZ098176
I1207129
IVS012749
Z015122
3 2 T0-3-8280/... E034106
EZ036479
I1207130
IVS041225
Z043598
3 3 T0-5-8281/... E048344
EZ050717
– IVS055463
Z057836
3 4 T0-6-8282/... E062582
EZ064955
– IVS069701
Z072074
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
2
1 3
4
FS 418
21
0
210
3210
2
1 3
4
5
6
FS 420
21
03
3210
4
2
1 3
4
5
6
7
8
FS 422
21
034
3210
45
2
1 3
4
5
6
7
8
9
10
FS 424
21
034
5
3210
456
2
1 3
4
5
6
7
8
11
1210
9
FS 426
21
034
65
210
2
1 3
4
5
6
7
8
9
10
11
12
FS 418
21
0
210
3
2
1 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
FS 420
21
03
210
34
2
1 3
4
5
6
7
8
9
10
11 13 15
12 14 16
17 19
18 20
21
22
23
24
FS 422
21
034
07/036 07/037
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Step Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Step Switches
Circuit diagram Front plate no.
No. of poles
Steps Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Step switches1)
One contact closed per step(without overlap)Without 0 (Off) position
1 2 T0-1-8220/... E031728
EZ095799
I1207078
IVS055459
Z086312
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
1 3 T0-2-8230/... E088685
EZ091058
I1207105
IVS095804
Z098177
1 4 T0-2-8231/... E012750
EZ015123
I1207106
IVS019869
Z022242
1 5 T0-3-8232/... E026988
EZ029361
I1207126
IVS034107
Z036480
1 6 T0-3-8233/... E041226
EZ043599
I1207127
IVS048345
Z050718
3 2 T0-3-8222/... E048339
EZ015118
I1207124
IVS060205
Z088686
3 3 T0-5-8270/... E091059
EZ093432
– IVS098178
Z010378
3 4 T0-6-8271/... E015124
EZ017497
– IVS022243
Z024616
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
12
2
1 3
4
FS 943
1 2
321
2
1 3
4
5
6
FS 404
32
1
321
4
2
1 3
4
5
6
7
8
FS 606
2
41
3
321
45
2
1 3
4
5
6
7
8
9
10
FS 408
32 4
51
321
456
2
1 3
4
5
6
7
8
9
10
11
12
FS 410
32 4
516
12
2
1 3
4
5
6
7
8
9
10
11
12
FS 943
1 2
321
2
1 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
FS 404
32
1
21
34
2
1 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
FS 406
23
14
07/038 07/039
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: On-Off Switches, Changeover Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: On-Off Switches, Changeover Switches
Circuit diagram Front plateno.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
On-Off switches1)
1 T0-1-15401/... E038854
EZ041227
I1207067
IVS045973
Z048346
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
2 T0-1-15402/... E053092
EZ055465
I1207068
IVS060211
Z062584
3 T0-2-15403/... E067330
EZ069703
I1207088
IVS074449
Z076822
4 T0-2-15404/... E081568
EZ083941
I1207089
IVS088687
Z091060
Changeover switches1)
1 T0-1-15421/... E095806
EZ098179
I1207069
IVS012752
Z015125
2 T0-2-15422/... E019871
EZ022244
I1207090
IVS026990
Z029363
3 T0-3-15423/... E034109
EZ036482
I1207114
IVS041228
Z043601
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
01
2
1
FS 415
01
01
2
1
4
3
FS 415
01
01
2
1 3
4
5
6
FS 415
01
01
2
1 3
4
5
6
7
8
FS 415
01
102
2
1 3
4
FS 429
02 1
102
2
1 3
4
5
6
7
8
FS 429
02 1
102
2
1 3
4
5
6
7
8
9
10
11
12
FS 429
02 1
07/040 07/041
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Hand/Auto Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Hand/Auto Switches
Circuit diagram Front plateno.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Hand/Auto switches1)
Hand/Auto switches with locking arrangement
a Page 07/052With 0 (Off) position
1 T0-1-15431/... E019872
EZ022245
I1207070
IVS026991
Z029364
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
2 T0-2-15432/... E034110
EZ036483
I1207091
IVS041229
Z043602
3 T0-3-15433/... E048348
EZ050721
I1207115
IVS055467
Z057840
With spring-return from HAND1 T0-1-15434/... E
062586EZ018053
I1207071
IVS069705
Z072078
2 T0-2-15435/... E003191
EZ003192
I1218971
IVS003195
Z003196
With spring-return from START1 T0-2-15907/... E
066931EZ069304
I1207095
IVS076423
Z078796
Without 0 (Off) position1 T0-1-15451/... E
076824EZ079197
I1207072
IVS083943
Z086316
2 T0-2-15452/... E091062
EZ093435
I1207092
IVS098181
Z010381
3 T0-3-15453/... E015127
EZ017500
I1207116
IVS022246
Z024619
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
0AUTO
HAND
2
1 3
4
FS 1401
0HAND AUTO
0AUTO
HAND
2
1 3
4
5
6
7
8
FS 1401
0HAND AUTO
0AUTO
HAND
2
1 3
4
5
6
7
8
9
10
11
12
FS 1401
0HAND AUTO
0HAND
AUTO
2
1 3
4
FS 1414000
0HAND AUTO
0AUTO
HAND
2
1 3
4
5
6
7
8
FS 1414000
0HAND AUTO
0AUTO
STARTHAND
2
1 3
4
5
6
7
8
FS 1413890
0AUTO HAND
START
HANDAUTO
2
1 3
4
FS 19334
HAND AUTO
HANDAUTO
2
1 3
4
5
6
7
8
FS 19334
HAND AUTO
HANDAUTO
2
1 3
4
5
6
7
8
9
10
11
12
FS 19334
HAND AUTO
07/042 07/043
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Spring-Return Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Spring-Return Switches
Circuit diagram Front plateno.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
On-switch (make contact)1)
Spring-return from position 11 T0-1-15321/... E
086317EZ088690
I1207064
IVS093436
Z095809
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
2 T0-1-15322/... E010382
EZ012755
I1207065
IVS017501
Z019874
3 T0-2-15323/... E024620
EZ026993
I1207087
IVS031739
Z034112
On-Off switch1)
Spring-return from positions 0 and 11 T0-1-15366/... E
081572EZ083945
I1207066
IVS088691
Z091064
On-Off switch1)
Spring-return from START1 T0-1-15511/... E
019875EZ022248
I1207073
IVS026994
Z029367
2 T0-2-15512/... E034113
EZ036486
I1207093
IVS041232
Z043605
3 T0-3-15513/... E048351
EZ050724
I1207117
IVS055470
Z057843
See K115 T0-2-8177/... E015130
EZ017503
I1207101
IVS022249
Z024622
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
1
2
1
FS 4721
1
1
2
1
4
3
FS 4721
1
1
2
1 3
4
5
6
FS 4721
1
1
0
2
1 3
4
FS 456
0 1
10
START
2
1 3
4
FS 147767
START
1
0
10
START
2
1 3
4
5
6
7
8
FS 147767
START
1
0
10
START
2
1 3
4
5
6
7
8
9
10
11
12
FS 147767
START
1
0
2
10
START
START
2
1 3
4
5
6
7
8
FS 140660
01 2
START START
07/044 07/045
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Universal Control Switches, Coding Switches, Series Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Universal Control Switches, Coding Switches, Series Switches
Circuit diagram Front plateno.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Universal control switches1)
Stay-put switches with 3 positions1 contact closed in each position; in addition:1 contact closed in positions 0 and 1 1 contact closed in positions 0 and 2 1 contact closed in positions 1 and 2
– T0-3-15391/... E029365
EZ031738
I1207112
IVS036484
Z038857
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
As above, but with spring-return from positions 1 and 2– T0-3-15394/... E
072079EZ074452
I1207113
IVS079198
Z081571
Coding switches1)
With complete rotation in both directionsDual BCD CODE
T0-4-15602/... E029368
EZ031741
I1207134
IVS036487
Z038860
Series switches1)
With 0 (Off) position(heater switches)
1 T0-1-91/... E072082
EZ074455
I1207080
IVS079201
Z081574
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
201
2
1 3
4
5
6
7
8
9
10 12
11
FS 429
02 1
201
2
1 3
4
5
6
7
8
9
10 12
11
FS 458
012
9876543210
2
1 3
4
5
6
7
8
9 11 13 15
10 12 14 16
42
0
3
9
6
8
1 5
7
FS 312
210
2
1
4
3
FS 614
0
21
07/046 07/047
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Instrument Selector Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesControl Switches: Instrument Selector Switches
Circuit diagram Front plateno.
No. of poles Flush mountingFront IP65
Centre mountingFront IP65
Surface mounting 2) IP65
Service distribution board mountingFront IP30
Rear mountingFront IP65
Notes
Basic typeFor ... insert mounting form
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Mounting formArticle no.
PriceSee Price List
Voltmeter selector switches1)
3
x phase to phase with 0 (Off) position
T0-2-15920/... E038861
EZ041234
I1207098
IVS029452
Z048353
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
3
x phase to phase without 0 (Off) position
T0-2-15922/... E053099
EZ055472
I1207100
IVS060218
Z062591
3
x phase to N with 0 (Off) position
T0-2-15921/... E067337
EZ069710
I1207099
IVS074456
Z076829
3
x phase to phase + 3
xphase to N with 0 (Off) position
T0-3-8007/... E095813
EZ098186
I1207120
IVS012759
Z015132
3
x phase to phase + 3
x phase to N without 0 position with complete rotation in both directions
T0-3-15924/... E019878
EZ022251
I1207119
IVS026997
Z029370
Ammeter selector switches1)
With complete rotation in both directionsMeasurement via current transformers
With 0 (Off) position T0-3-8048/... E034116
EZ036489
I1207122
IVS041235
Z043608
Voltmeter and ammeter selector switches1)
With complete rotation in both directionsMeasurement via current transformers(For other circuits
a catalogue K115)With 0 (Off) position T0-3-8030/... E
013401EZ013402
I1207121
IVS013404
Z013406
Standard pack: 1 off Standard pack: 1 off
Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070
0
L3+L1L2+L3L1+L2
2
1 3
4
5
6
7
8
L1-L2L2-L3
L3-L10
FS 1410755
L3-L1L2-L3L1-L2
2
1 3
4
5
6
7
8
L1-L2L2-L3
L3-L1
FS 164854
0
L3-NL2-NL1-N
2
1 3
4
5
6
7
8L1-N
L2-NL3-N
FS 1410757
0
0
L3-NL2-NL1-N
L1-L2L2-L3L3-L1
2
1 3
4
5
6
7
8
9 11
10 12
L1-L2
FS 1410759
0
L2-L3
L3-L1
L1-N
L2-N
L3-N
L3-NL2-NL1-NL3-L1L2-L3L1-L2
2
1 3
4
5
6
7
8
9 11
10 12
L1-L2L2-L3
L3-L1
L1-NL2-N
L3-N
FS 164721
0
L3L2L1
2
1 3
4
5
6
7
8
9
10 12
11 L1
L2
FS 9440
0
L3
0
201
2
1 3
4
5
6
7
8
9
10 12
11
FS 928
1
2
0 0
07/048 07/049
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsSwitches with Locking Arrangements
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsSwitches with Locking Arrangements
Circuit diagram
Front plateno.
No. of poles
Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz
Rated uninter-rupted current
Flush mountingIP65
Surface mounting 3) IP65
Rear mountingIP65
Notes
AC-3220 V230 V240 V
380 V400 V440 V
660 V690 V
Iu TypeArticle no.
PriceSee Price List
TypeArticle no.
PriceSee Price List
TypeArticle no.
PriceSee Price ListkW kW kW A Std. pack
Switches with locking arrangements, KMS1 lock mechanismPanic switches without Emergency-Stop function1)
With SVA cylinder lock Key withdrawable in positions 0 and 1 When the key is withdrawn in position 1, the switchcan still be switched Off, but cannot be switched back On again without the key
3 3 4 4 20 T0-2-1/E/SVA(S)050977
T0-2-1/I1/SVA(S)207084
– 1 off
Code letters for lockable switch positionsLetter S for panic lock with FS908GE
4 5.5 7.5 25 P1-25/E/SVA(S)050966
P1-25/I2/SVA(S)207305
–
5.5 11 15 32 P1-32/E/SVA(S)044977
P1-32/I2/SVA(S)207326
–
5.5 11 15 32 T3-2-1/E/SVA(S)050983
T3-2-1/I2/SVA(S)207173
–
On-Off switch without Emergency-Stop function1)
With SVA cylinder lockKey withdrawable in 0 position only (code letter A)
3 3 4 4 20 T0-2-1/E/SVA(A)050976
T0-2-1/I1/SVA(A)207083
T0-2-1/Z/SVA(A)050978
4 5.5 7.5 25 P1-25/E/SVA(A)050965
P1-25/I2/SVA(A)207304
P1-25/Z/SVA(A)050969
5.5 11 15 32 P1-32/E/SVA(A)050970
P1-32/I2/SVA(A)207325
P1-32/Z/SVA(A)050973
5.5 11 15 32 T3-2-1/E/SVA(A)050982
T3-2-1/I2/SVA(A)207172
T3-2-1/Z/SVA(A)050984
Panic switches with Emergency-Stop function2)
With SVA cylinder lockKey withdrawable in positions 0 and 1 When the key is withdrawn in position 1, the switchcan still be switched Off, but cannot be switched back On again without the key
3 3 4 4 20 T0-2-1/E/SVA(S)-RT228971
T0-2-1/I1/SVA(S)-RT207085
–
4 5.5 7.5 25 P1-25/E/SVA(S)-RT050967
P1-25/I2/SVA(S)-RT207306
–
5.5 11 15 32 P1-32/E/SVA(S)-RT050971
P1-32/I2/SVA(S)-RT207327
–
5.5 11 15 32 T3-2-1/E/SVA(S)-RT044972
T3-2-1/I2/SVA(S)-RT207174
–
Panic switches with Emergency-Stop function2)
With SVC padlocking feature Locking slide can be padlocked in positions 0 and 1. When the locking slide is padlocked in position 1, the switch can still be switched Off, but cannot be switched back On again without first removing the padlock. Lockable using up to 3 padlocks.
3 3 4 4 20 T0-2-1/E/SVC(S)-RT044973
T0-2-1/I1/SVC(S)-RT207086
–
4 5.5 7.5 25 P1-25/E/SVC(S)-RT044974
P1-25/I2/SVC(S)-RT207307
–
5.5 11 15 32 P1-32/E/SVC(S)-RT044975
P1-32/I2/SVC(S)RT207328
–
5.5 11 15 32 T3-2-1/E/SVC(S)-RT044976
T3-2-1/I2/SVC(S)-RT207175
–
On-Off switches without Emergency-Stop function1)
With S-T0 key operation Key withdrawable in position 0 only (code letter A)
2 2.2 2.2 – 20 T0-1-102/EZ/S014933
4) T0-1-102/I1/S207063
T0-1-102/Z/S014971
Notes 1) With black thumb-grip and grey front plate2) To IEC/EN 60204-1; with red thumb-grip and yellow front plate
3) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/0704) Degree of protection IP53
1 3 5
2 4 6
FS 908
ON
OFF
330 0 30
300
240225
210180
150
135120
90
6045
270
F
HG
J
KL
MN
PQ
R
A
BC
DE
315
1 3 5
2 4 6
FS 908
ON
OFF
1 3 5
2 4 6
FS 908 GE
1
0
1 3 5
2 4 6
FS 908 GE
1
0
1
2
3
4
FS 908
ON
OFF
07/050 07/051
Moeller HPL0211-2001/2002
T Rotary SwitchesSwitches with Locking Arrangements
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary SwitchesSwitches with Locking Arrangements
Circuit diagram
Front plateno.
Rated uninter-rupted current
Flush mountingFront IP65
Surface mounting1) IP65
Rear mountingFront IP65
Notes
Iu TypeArticle no.
PriceSee Price List
TypeArticle no.
PriceSee Price List
TypeArticle no.
PriceSee Price ListA Std. pack
Switches with locking arrangements, KMS1 lock mechanismHand/Auto switches with SVA cylinder lock
Suitable for actuating electronic devicesRated uninterrupted current
Iu 20 ARated operational current
Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A
Additional Technical Data
a Page 07/090
Rotary switches with an SVA locking arrangement can also be used as Operating Mode Selector Switches for the purposes of EU Machine Directive 89/392 (Minimum switching angle: 60°)
Code letters for lockable switch positions
Key withdrawable in all positionsWhen the key is withdrawn in the HAND position, then START can be actuated without first removing the padlock, but not position 0(only admissible with separate Off switch)
20 T0-2-15907/E/SVA(C,E,G-J)050979
T0-2-15907/I1/SVA(C,E,G-J)207096
– 1 off
32 T3-2-15907/E/SVA(C,E,G-J)050985
T3-2-15907/I2/SVA(C,E,G-J)207176
–
Hand/Auto switches with SVC padlocking feature
Locking slide can be padlocked in all positions.When the locking slide is padlocked in the HAND position, then START can be actuated without the key,but not position 0 (only admissible with separate Off switch)
20 T0-2-15907/E/SVC(C,E,G-J)044996
T0-2-15907/I1/SVC(C,E,G-J)207097
T0-2-15907/Z/SVC(C,E,G-J)050980
32 T3-2-15907/E/SVC(C,E,G-J)044997
T3-2-15907/I2/SVC(C,E,G-J)207177
T3-2-15907/Z/SVC(C,E,G-J)050986
Notes 1) Enclosure designed for metric cable glands to EN 50 262, cable glands
a Page 07/070Contactor interlocking circuitsControl section for standard contactor interlocking circuits.If a standard switch is to contain one of the contactor interlocking circuits as well, it can be ordered using another circuit number from catalogue K115, or as a non-standard switch.
The electrical interlocking of rotary switch and contactor makes possible a wide range of control functions.For example: remote disconnection via a stop switch, overload protection via overload relays, protection against automatic restarting after a power failure or overload, and Off position interlocking, etc.
SOND 27 SOND 28 SOND 29 SOND 30
Mains disconnection only by contactor.Restarting possible only with the rotary switch in the Off position.Application: primarily for star-delta circuits (only at 60 or 90° switching angles)
Mains disconnection by contactor and rotary switch together Restarting: as SOND 27 Application: primarily for star-delta and changeover circuits (only at 60 or 90° switching angles)
Mains connection by contactor, only with the rotary switch in the Off position (Off position interlock)Application: star-delta, changeover and multi-speed circuits
Mains connection by contactor, only with the rotary switch in a run position Each change in the switch position causes the contactor to drop out Application: changeover and multi-speed circuits
330 0 30
300
240225
210180
150
135120
90
6045
270
F
HG
J
KL
MN
PQ
R
A
BC
DE
315
0AUTO
STARTHAND
2
1 3
4
5
6
7
8
FS 1413890
0AUTO HAND
START
0AUTO
STARTHAND
2
1 3
4
5
6
7
8
FS 1413890
0AUTO HAND
START
F0
F2
S0
K1M
K1M
Q1
0 21
M3~
K1M
ControlsectionSOND 27
Powersectionwithoutmainsdisconnection
Contactsequence asrequired
F0
F2
S0
K1M
K1M
Q1
0 1 2
M3~
KM1
ControlsectionSOND 28
Powersectionwithmainsdisconnection
Contactsequence asrequired
K1M
F0
F2
K1M
K1M
S1
Q1
0 1 2
M3~
S0Control sectionSOND 29
Powersection
Contactsequence as required
K1M
F0
F2
S0
K1M
K1M
S1
Q1
10 2
M3~
Control sectionSOND 30
Powersection
Contactsequence as required
07/052 07/053
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsFront Plates
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsFront Plates
Standard front plates Emergency-Stop front plates Blank plates Non-standard front plates Non-standard front platesSwitch size Dimensions Yellow Can be engraved
TypeArticle no.
PriceSee Price List
Std. pack TypeArticle no.
PriceSee Price List
Std. pack TypeArticle no.
PriceSee Price List
Std. pack TypeArticle no.
PriceSee Price List
Std. pack Height of letters
mm
State the front plate no. required
F 2 characters
mm
> 2 characters
mm
Standard Front platesT0, T3, P1 45
x 45 (for frame size 48
x 48)FS...-T0903197
10 off FS908 GE-T0003198
5 off FS980-T0003199
50 off FS-SOND-ERSTBESTELLUNG-T01)
2253555 off 4 3
P3, T5, T5B 84
x 84 (for frame size 88
x 88)FS...-P3995545
10 off FS908 GE-P3031475
5 off FS980-P3043340
50 off FS-SOND-ERSTBESTELLUNG-P32)
2253565 off 8 5
TM 29
x 29 (for frame size 30
x30 )– – FS980-TM-E
07143810 off FS-SOND-TM-E
0928295 off 3.5 2.5
– – FS980-TM-EZ073811
50 off FS-SOND-TM-EZ095202
5 off 3.5 2.5
1) = first order; for subsequent orders use FS...-T02) = first order; for subsequent orders use FS...-P3
Standard front plates Non-standard front platesThe standard front plates illustrated should be used for non-standard switches where possible. Standard catalogue front plates for standard switches can be exchanged on request with order, for those illustrated here, at no extra charge (not applicable to T6, T8 and TM), provided the switching angles, the number of switch positions, and the location of the 0 (Off) position match.Example: T0-1-8210/E+FS161570
Inscription to order (note maximum number of characters per field).The FS number is sufficient for reordering.For non-standard T0, T3 and T5(B) switches, the front plate is included in the price.For standard switches, the front plate is included in the price for orders exceeding 49 off.
a Page 07/113Switching angle 90°
Switching angle 60° Standard front platesarranged in their numerical sequence:
Switching angle 45°
Switching angle 30 °
1
0
HEIZUNG-NOTSCHALTER
AUS
EIN
STOP
ON OFF
EIN START AUTO ZU SLOW
ZU
OFF
AUS STOP HAND AUF ABAUF DOWNUP FAST
AUTO
AUF
AUS
L3
L2
L1
908
0
1
9508
2
1
902 190719
1
193935
0
1
907
0 1
945 1992
1 2
943 19334 190550 19143 193975 190431
192219589
0
T R
S
935
0
9440
2
1 3
4
906
1
0 2
3
912
1+2
1
0
2
1938409441
0
0
1 2
1
2 2
1
923
1
2
0 0
9281921911957
1
0 0
1
926
2
1 3
904
21
192190
0
1 2
953
0 2
1
910
190334
L3
L2
L1
OFF
ONON ONOFFOFF OFF
ON
OFF
ON
OFF
911
13
0
2
START
RUN
STOPSTART
RUN
SLOW
FAST
STOPSLOW
FAST
STOPAUTOSLOWHAND
FAST STOPSTART
RUN NETZAUF
HALTNOT-STROM
AB AUF AB
HALTHALTLINKS RECHTS
AUTO
AUS
HAND AUTO
AUS
HAND AUTO
OFF
HAND
OFF
L2-N L2-L3AUTO
OFFMAN REV.
OFFFORW.
STOPSLOW FAST REV.
STOPFORW. L1-N L3-N
01
611
12
601 1601
01
2
644 16052 635
Y0
16616 684
01 2
621
012
161629
0
161570
0
161359 161358 1610 1614 1673 1617
2 1
6034
0 Y
606
2
41
3
160772616
1
0
2
3
604
2
1
3
614
0
21
164854164855655
21 3
1665166216281627
01
164222
2
1
3
4
0
667 645
2
13
4
0
629
10
12 2
161002 638
Y0
Y
161683
1
0
2
3
4
618 620
1
0
2
345
610
2
1
3
4
56
640
2
10
0
2
1
Y0
0Y
6010 164721 661
L1-L2 L3-L1HIGHOFF
MED.LOW
S-TT-R
R-O
R-S
T-OS-O
L2-L3L3-L1L1-L2
L3-N L1-NL2-N
START
301
12
3 4 567
891011
12
310
12 3 4
56
78910
110
302
12
3 4 5 67
891011
311
12 3 4
56
78910
0
303
12
3 4 567
8910
312
42
0
3
9
6
8
1 5
7
304
12
3 4 567
89
313
12 3 4 5
67
8
0
305
12
3 4 567
8
314
12 3 4
56
70
315
12 3 4
560
307
12
3 4 56
316
12 3 4
50
308
12
3 4 5
317
12 3 4
0
309
12
3 4
408
32 4
51
414
21
345
687
428
0
21 3
4567
412
32
1
7 65
4
426
21
034
65
410
32 4
516
424
21
034
5
422
21
034
406
23
14
420
21
03
404
32
1
418
21
0
429
02 1
01
415
12
402 416
01
610
2
1
3
4
56
614
0
21
604
2
1
3
616
1
0
2
3
606
2
41
312
601
01
611496
1 2
453
23 1
4
0
449
0
211
233
459
21
0
21
456
0 1
458
012
462
21
0
461
01
2
455
10
2
1 3
904
2
1 3
4
906
0
1
907
2
1
902640
2
10
0
2
1
620
1
0
2
345
638
Y0
Y
635
Y0
621
012
629
10
12 2
01
2
644 645
2
13
4
0
655
21 3
661
2
1
3
4
0
667 684
01 2
14201411
02 1
1409140414031401
0
980
0
1 2
953
0 1
945
1 2
943
0
T R
S
935
1
2
0 0
928
1
0 0
1
926
1
2 2
1
923
0 2
1
910
1423
1
1426
0
1446
0
1475 1601 1610 1614 1617
2 1
1627 1628 1662 1665 1673 1922 1957 1992 4011
01 2
4017
Y0
Y
4026
20
1
4117
20
1
4721
1
4722
1 0
4723
0
Y0
0Y
6010 6034
0 Y0
9440 9441
0
0
1 2 0
1
9508 14195
0
14196
0
14510
1
14712 14944
0
147474
0
147472142074
0
2 1
142003141883141879141538141537140660
01 2
140055
0
41409
1 20
195891933419143166161605214988
0
147479 147767
1
0
160772 161002 161358 161359 161570
0
161629
0
161683
01
164222 164721 164854 164855 190334 190431 190550 1907190
141400014139051413903
0
1413890
0
14107631410759
0
1410758
0
1410757
0
1410756
0
1410755
0
194323194321193975
1
193935
1+2
1
0
2
193840192191
21
192190
S-TT-RR-S
S-OT-O R-O
S-T
T-R R-SS-O
R-OR-SS-O
T-O
HAND AUTO
S-T
T-R
T-O R-O
ZU-RUCK
HALTVOR. LINKS RECHTS
HALT
STARTSTART
AUTOAUS
HAND HAND AUTOOFF
EINAUS
OFF
ONAUTO
HAND
AUS
AUTO
OFF
ON
OFFZU AUF
STARTSTART
STOPFORW. REV.
TRIP CLOSE
AUTO
HAND
HAND HANDAUTO
AUTO
AUSAUSAUTO
OFFOFFOFF OFFMANMAN REV. FORW.
STOPSLOW FAST
AUTOHAND
EINAUS EINAUS LINKS RECHTS LANG-
SAM
AUSSCHNELL
EIN
AUS
STOP START
STOP
START START
FORW. REV.
OFFON
STOP
START
STOP
START
HANDAUTO
HEIZUNG-NOTSCHALTER
STOP
FORW. REV.STARTSTART
START
L3 L1
L2
L3 L1
L2
OFFABAUFSTOP
STARTRUNSTOP
SLOWFAST
ZUAUF
ZUAUF S-T
T-R
R-S R-S
S-T
T-R
STOP START SLOW FASTL2-NL3-NL1-N
L2-L3L3-L1L1-L2
DOWNOFF
UPL2-L3
L3-L1L1-L2L2-N
L3-N
L1-N
L2-L3
L3-L1
L1-L2L2-NL3-N
L1-N
L2-L3
L3-L1
L1-L2L2-N
L3-NL1-NL2-L3
L3-L1
L1-L2L1-L2
L2-NL3-N L1-N
L2-L3L3-L1L1-L2
L2-N
L3-N L1-NL2-L3L3-L1
L1-L2
L1-N
OFF
L2-L3
L3-L1 L1-L2
OFFOFF
ON
LOW
START
OFF
OFF
OFF
ON
L2-N
L3-N
L1-NL2-L3
L3-L1
L1-L2OFF MED.
HIGH
STOPSLOW SLOW
FAST FAST
STOP
LINKS RECHTSHALT
ABAUF
HALT
ABAUFNETZ
NOT-STROM STARTSTART
RUNRUN
STOP
HANDAUTO HAND AUTO HANDOFF
RAISESTART LOWER
AUTO
142010
1
0 START
911
13
0
2
318
12 3
0
441
10
12 2
1
0
2
3
4
618
908
ON
OFF
912
20
1
3
OFFON
STOP
STARTAUTO
HAND
START
STOPAUTOHAND
HAND AUTO AUTOOFF
AUTOAUS
HAND
416
01
12
402
01
415 142003 147472 141883 455
10
142010
1
0
141879 4721
1
4722
1 0
4723
0
496
1 2
41409
1 20
429
02 1
1401
0
1413905
0
14140004117
20
1
462
21
0
4026
20
1
461
01
2
147767
1
0
14153814031404147514201411
4011
01 2
458
012
1426
0
14988
0
147474
0
1413903
0
1446
0
456
0 1
1423
1
14510
1
141537 1413890
0
418
21
0
404
32
1
420
21
03
406
23
14
422
21
034
408
32 4
51
441
10
12 2
453
23 1
4
0
4017
Y0
Y
459
21
0
21
1409
02 1
140660
01 2
14712 142074
0
2 1
424
21
034
5
410
32 4
516
426
21
034
65
412
32
1
7 65
4
449
0
2112
33
428
0
21 3
4567
414
21
345
687
1410757
0
14196
0
1410755
0
14195
0
1410756
0
1410758
0
1410759
0
147479 14944
0
1410763 140055
0
194321 194323
HAND AUTOOFF
LANG-SAM
AUSSCHNELL ZU-
RUCKLINKS RECHTS
HALT HALTVOR.
STOP
STARTFORW. REV. HAND
TRIPEIN CLOSEAUS ZUAUFRAISE LOWER
LINKS RECHTSEINAUS STARTSTOP
STOP
FORW. REV. START
START
AUTO HAND
STARTSTART
START
REV.STOP
START
FORW.
STARTSTARTSTARTSTART
L2-NL3-NL1-N
S-OT-OR-O
L2-L3L3-L1L1-L2
L2-N
L3-N
L1-N
L2-L3
L3-L1
L1-L2S-T
T-RR-S L2-L3L3-L1
L1-L2L2-NL3-NL1-N
L1-N
L1-L2 L2-N
L3-N
L1-NL2-L3
L3-L1
L1-L2OFF OFF
L2-L3
L3-L1
L1-L2
L2-N
L3-N L1-N
OFF OFF
L2-L3
L3-L1
L1-L2
L2-L3
L3-L1 L1-L2S-T
T-R
R-S
S-O
T-O
R-O
S-T
T-R
R-S R-S
S-T
T-R
318
12 3
0
309
12
3 4
317
12 3 4
0
308
123 4 5
316
12 3 4
50
307
12
3 4 56
315
12 3 4
560
314
12 3 4
56
70
305
12
3 4 5678
313
12 3 4 5
67
8
0
304
12
3 4 567
89
312
42
0
3
9
6
8
1 5
7
303
12
3 4 5678
910
311
12 3 4
56
78910
0
302
12
3 4 567
891011
310
12 3 4
56
78910
110
301
12
3 4 567
891011
12
07/054 07/055
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type suffix Price Std. pack Type Price Std. pack Type suffix Price Std. pack Type PriceArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
ListStd. pack
When orderedwith basic unit
When ordered separately
When orderedwith basic unit
When ordered separately
Add-on front plates, clip-on
For use with front plates and for padlocking features. They comprise a black label mount and an insert plate.Blank, can be engraved T.../I2/SVB(-SW) and
P.../I2/SVB(-SW) except...I1, 2.../IVS T..., P..., except.../I1, 2, 3 .../IVS
– ZFS60-T0019924
25 off – ZFS60-P3022297
25 off ZFS...-T0 and ZFS...-P3 can be used for any T... and P...switches, as required. Dimensions with frame W
x H = 48
x 17 mmDimensions with frame W
x H = 88
x 27 mm
With inscription: “Main switch - Open only in the Off position“
T.../E, T.../Z, P.../E, P.../Z 61/62 = German/English63 = French64 = Bulgarian65 = Danish66 = Finnish67 = Dutch68 = Italian69 = Greek70 = Norwegian71 = Polish72 = Portuguese73 = Romanian74 = Russian75 = Swedish76 = Serbo-Croat77 = Spanish78 = Czech79 = Turkish80 = Hungarian81 = Afrikaans
+ZFS61/62-T0065740
1off ZFS61/62-T0030170
25 off +ZFS61/62-P3065742
1off ZFS61/62-P3065739
25 off ZFS61/62-... included as standard withT.../EA/SVB, P.../EA/SVBT.../V/SVB, P.../V/SVB+ZFS63-T0
065741ZFS63-T0047424
+ZFS63-P3065743
ZFS63-P3047423
+ZFS64-T0205501
ZFS64-T0205535
+ZFS64-P3205518
ZFS64-P3205552
+ZFS65-T0205502
ZFS65-T0205536
+ZFS65P3205519
ZFS65P3205553
+ZFS66-T0205503
ZFS66-T0205537
+ZFS66-P3205520
ZFS66-P3205554
+ZFS67-T0065744
ZFS67-T0065750
+ZFS67-P3065747
ZFS67-P3065753
+ZFS68-T0065745
ZFS68-T0065751
+ZFS68-P3065748
ZFS68-P3065754
+ZFS69-T0205504
ZFS69-T0205538
+ZFS69-P3205521
ZFS69-P3205555
+ZFS70-T0205505
ZFS70-T0205539
+ZFS70-P3205522
ZFS70-P3205556
+ZFS71-T0205506
ZFS71-T0205540
+ZFS71-P3205523
ZFS71-P3205557
+ZFS72-T0205507
ZFS72-T0205541
+ZFS72-P3205524
ZFS72-P3205558
+ZFS73-T0205508
ZFS73-T0205542
+ZFS73-P3205525
ZFS73-P3205559
+ZFS74-T0205509
ZFS74-T0205543
+ZFS74-P3205526
ZFS74-P3205560
+ZFS75-T0205510
ZFS75-T0205544
+ZFS75-P3205527
ZFS75-P3205561
+ZFS76-T0205511
ZFS76-T0205545
+ZFS76-P3205528
ZFS76-P3205562
+ZFS77-T0065746
ZFS77-T0065752
+ZFS77-P3065749
ZFS77-P3047422
+ZFS78T0205512
ZFS78T0205546
+ZFS78-P3205529
ZFS78-P3205563
+ZFS79-T0205513
ZFS79-T0205547
+ZFS79-P3205530
ZFS79-P3205564
+ZFS80-T0205514
ZFS80-T0205548
+ZFS80-P3205531
ZFS80-P3205565
+ZFS81-T0205515
ZFS81-T0205549
+ZFS81-P3205532
ZFS81-P3205566
Label mounts, blackT.../I2/SVB(-SW) and P.../I2/SVB(-SW) except...I1, 2.../IVS
T..., P..., except.../I1, 2, 3 .../IVS
– ZFSX-T0024670
25 off – ZFSX-P3027043
25 off ZFSX...-T0 and ZFSX...-P3 can be used for any T... and P...switches, as required. ZFSX...-T0: dimensions with frame W
x H = 48
x 17 mmZFSX...-P3: dimensions with frame W
x H = 88
x 27 mm
07/056 07/057
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Key withdrawal Type suffix Price Key withdrawal Type PriceArticle no. See Price
ListArticle no. See Price
ListStd. pack Notes
When orderedwith basic unit
When ordered separately
S-T0 key operated lock mechanism, Front IP53
Includes two keys
KMS 1 lock mechanismIndividual lock mechanism, not suitable for master key systems
T0-.../E, .../I1, .../Z Up to 6 contact unitsT3-.../E, .../I2, .../Z Up to 5 contact unitsP1-.../E, .../I2, .../Z
Key withdrawal positions are programmed ex-works to match the switch
+S-T0001753
Key withdrawal positions can be programmed by the user
S-T0086709
1 off S-T0 can be used for P1-..., T0-1... to T0-6... and T3-1... to T3-5... switches.The key replaces the thumb-grip. Switching is not possible with-out the key. The switch position indicator is on the lock. In standard applications, the key can be withdrawn in any position, on switches with FS908, only in the Off position. New positions for key withdrawal can be selected (even retrospectively) by fitting VR-T0 locking cams.The switching angle is determined by the switch.When retrofitting the S-T0, use the front plate of the switch.Lock mechanism: standard KMS 1 (CES lock)
SVA-T3 can be fitted to T0, T3 and P1 switches. Switching is carried out using the thumb-grip.The switch is locked by turning the key; the key is withdrawable. In standard applications, all positions are lockable. Lock mechanism: standard KMS 1 (CES lock). Individual positions or ranges can be locked (also with VR-T3 fitted by the user). The key cannot be withdrawn in positions which are not lockable. Where ranges are locked, switching without the key is possible only within a locked range.The lockable positions or ranges are shown below; use the code letters to state your selection on the order:Example 1: SVA(A)-T3 = Only position A lockableExample 2: SVA(A, E)-T3 = Positions A and E lockableExample 3: SVA(A–J)-T3 = Range A to J lockableExample 4: SVA(S)-T3 = Main switches, for use as Emergency-Stop devices to IEC/EN 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions A and E; switching is still possible from E to A, but not from A to E.When retrofitting the SVA-T3, use the front plate of the switch. With letter S for panic lock, use FS908GE. Ordering example: P1-25/I2-RT+SVA(S)-T3.
Letter S for panic lock with FS908GE
Ordering example:SVA(A-G)-SOND-(SAA 6294-1/2)
KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems
+S-SOND(KMS...)-T0903210
S-SOND(KMS...)-T0903207
There is no master key for KMS...- lock mechanisms(SAE) = Individual lock mechanism supplied with a security certificate
+S-SOND(SAE)-T0003212
S-SOND(SAE)-T0003209
(SA...) = Master key system (with master key) supplied with a security certificate. See also note below.2)
+S-SOND-(SA...)-T0914737
S-SOND-(SA...)-T0991023
SVA-T3 cylinder lock, Front IP65
Includes two keys
Key withdrawable in all positions KMS 1 lock mechanismIndividual lock mechanism, not suitable for master key systems
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z
Key withdrawal positions are programmed ex-works to match the switch
+SVA-T3050962
Key withdrawal positions can be programmed by the user
SVA-T3050974
1 off
KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems
+SVA-SOND-KMS...-T3907739
SVA-SOND-KMS...-T3907747
Key can be withdrawn in positions as specified KMS 1 lock mechanismSwitches with FS 908 are suitable as main switches:T0-1-... to T0-4-.../I1, .../E T3-1-... to T3-5-.../I2T3-1-... to T3-6- .../EP1-.../I2, .../E
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z
Key withdrawal positions are programmed ex-works as ordered
+SVA(...)-T3907737
Key withdrawal positions are programmed ex-works as ordered
SVA(...)-T3907745
KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems
+SVA(...)-SOND-KMS...-T3907734
SVA(...)-SOND-KMS...-T3907742
(SAE) = Individual lock mechanism supplied with a security certificate
+SVA(...)-SOND-SAE-T3907736
SVA(...)-SOND-SAE-T3907744
(SA...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan (FO276) showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (X4711, item 7).2)
+SVA(...)-SOND-(SA...)-T3914735
SVA(...)-SOND-(SA...)-T3914736
Notes 1) KMS 1: can be supplied ex-stock; KMS 2 – 10, 201 – 400and master key systems: delivery time < 6 weeks from order receipt at the factory
2) For subsequent orders, the keys must be ordered separately
a Page 07/061
330 0 30
300
240225
210180
150
135120
90
6045
270
F
HG
J
KL
MN
PQ
R
A
BC
DE
315
07/058 07/059
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Locking facility Type suffix Price Locking facility Type PriceArticle no. See Price
ListArticle no. See Price
ListStd. pack Notes
When orderedwith basic unit
When ordered separately
SVC-T3 padlocking feature, Front IP65
In the depressed position, the locking slide is lockable with up to 3 padlocks
All positions are lockable T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z
Lockable positions are programmed ex-works to match the switch
+SVC-T3050963
Lockablepositions can be programmed by the user
SVC-T3050975
1 off SVC-T3 can be fitted to T0, T3 and P1 switches. Switching is carried out using the thumb-grip,and interlocking by depressing an actuator which can be locked in position using up to 3 padlocks. In standard applications, all positions are lockable. With type reference SVC(...)-T3, only the specified positions or ranges are lockable. Where ranges are locked, switching is possible only within a locked range, unless the padlock is removed first.The lockable positions or ranges for SVC(...)-T3 and the locked position for DTV(...)-T3 are shown below. As with SVA(...)-T3, use the code letters to state your selection on the order:Example 1: SVC(A)-T3 = Only position A lockableExample 2: SVC(A, E)-T3 = Positions A and E lockableExample 3: SVC(A–J)-T3 = Range A to J lockableExample 4: DTV(G)-T3 = The release mechanism must be actuated to allow switching in this position.Example 5: SVC(S)-T3 = Main switches, for use as Emergency-Stop devices to IEC / EN 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions A and E; switching is still possible from E to A, but not from A to E.When retrofitting the SVA-T3, use the front plate of the switch. With letter S for panic lock, use FS908GE. Ordering example: P1-25/I2-RT+SVC(S)-T3
Master keys must always be ordered separately. Please send or submit the security certificate with repeat orders. For SA(...), the precise designation of the key must be stated e.g. SVS-SA(A6294-1/2)
Specified positions or ranges are lockableSwitches with FS908 may be used as main switches for
T0-1-... to T0-4-.../I1, .../ET3-1-... to T3-5-.../I2 T3-1-... to T3-6-.../E P1-.../I2, .../E
Lockable positions are programmed ex- works as ordered
+SVC(...)-T3907740
Lockable positions are programmed ex- works as ordered
SVC(...)-T3907748
1 off
DTV-T3 push-button interlock, Front IP65
Only after depressing the release button is it possible to switch from an unlocked position or range into a locked position or range, but not the reverse (protection against tampering).With a padlock in place when the release button is in the non-actuated position, it is not possible to switch into the locked positions.
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z Lockable using2 padlocks
Lockable positions are programmed ex-works to match the switch
+DTV-T3050961
– 1 off
Specified positions lockedRelease mechanism can be locked in the non-actuatedposition with 1–2 padlocks
Lockable positions are programmed ex- works as ordered
+DTV(...)-T3907733
– 1 off
Locking cams (2 cams per set)For user to select indexingposition in which key canbe withdrawn
S-T0 for all switching angles – VR-T0089082
1 off
For changing the locked positions/ranges SVA-T3, SVC-T3, for all switching anglesfor DTV-T3: order 2
x VR-T3– VR-T3
0509871 off
Keys
For KMS 1 individual lock mechanism S-T0, SVA-T3 – SVS-KMS1001871
1 off
For KMS 2 – 10 individual lock mechanismor KMS 201 – 400
S-T0, SVA-T3 – SVS-KM...914714
For master key systems andrecorded individual lock mechanisms: state lockplan no. and lock
S-T0, SVA-T3 – SVS-SA(...)901982
330 0 30
300
240225
210180
150
135120
90
6045
270
F
HG
J
KL
MN
PQ
R
A
BC
DE
315
07/060 07/061
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type suffix Price Type PriceArticle no. See Price
ListArticle no. See Price
ListStd. pack
When orderedwith basic unit
When ordered separately
Main switch assembly kits
Padlocking feature, exclusively for main switches, to permit them to be used as Emergency-Stop devices1)
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2
+SVB-T0026450
SVB-T0057892
1 off For locking in the 0 (Off) position:For switches with the positions 0 – I at 90° switching angle, as front plate: FS908
T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5
+SVB-P3026364
SVB-P3052999
1 off
Padlocking feature, exclusively for main switches without Emergency-Stop functionBlack handle, black locking collarAdmissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2
+SVB-SW-T0076917
SVB-SW-T0060265
1 off For locking in the Off position or in the On position if required.Lockable using up to 3 padlocks
Padlocks with KMS lock mechanism, Type 219/38 (KMS...): please enquire.
T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5
– SVB-SW-P3062491
1 off
Main switch assembly kits, with PE terminal and N terminal
Padlocking feature, exclusively for main switches, to permit them to be used as Emergency-Stop devices1)
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z T3-.../E, .../Z
– V/EA/SVB-T0062638
1 off For conversion of:
• T.../E flush mounting switches (with front plate FS908) into T.../EA/SVB... flush mounting main switches
• T.../Z rear mounting switches (with front plate FS908) into T.../V/SVB interlocked rear mounting main switches
T5(B)-.../E, .../Z – V/EA/SVB-T5045065
Padlocking feature, exclusively for main switches without Emergency-Stop functionBlack handle, black locking collarAdmissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z T3-.../E, .../Z
– V/EA/SVB-SW-T0065011
T5(B)-.../E, .../Z – V/EA/SVB-SW-T5045064
Thumb-grips
Black T0-.../E, .../EZ, .../IVS, .../Z, .../I1 T3-.../E, .../EZ, .../IVS, .../Z, .../I2 P1-.../E, .../EZ, .../IVS, .../Z, .../I2
– KNB-T0038909
1 off
Red T0-.../E, .../IVS, .../Z, .../I1 T3-.../E, .../IVS, .../Z, .../I2 P1-.../E, .../IVS, .../Z, .../I2
+KNB-RT-T0003214
KNB-RT-T0043655
When ordered separately:Use red handle to IEC/EN 60 204 for Emergency-Stop switches only, and order corresponding yellow front plate FS908GE-T0
Black T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5
– KNB-P3041282
1 off
Red T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5
+KNB-RT-P3003215
KNB-RT-P3046028
When ordered separately:Use red handle to IEC/EN 60 204 for Emergency-Stop switches only, and order corresponding yellow front plate FS908GE-P3
Maintenance keysFor interlocked main switches T0-.../V, T3-.../V, P1-.../V – KNK-T0
0006501 off Special devices for electricians, to allow them to switch
interlocked main switches On and Off, when the panel door is open for maintenance purposes (to IEC/EN 60 204 Part 1, Clause 5.1.1.1)
T5(B)-.../V, P3-.../V – KNK-P3000649
1 off
Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position
07/062 07/063
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type suffix Price Type PriceArticle no. See Price
ListStd. pack Article no. See Price
ListStd. pack
When orderedwith basic unit
When ordered separately
Neutral poles
Early-make, late-break
Can be fitted to left and/or right of 3-pole P switch-disconnectors P1-.../E, .../EA, .../EZ – N-P1E000651
5 off The neutral contact is always early-make and late-break.
Switching capacity of N-P1... equivalent to P1-32... contacts
with P1-.../I2:optional N-P1Z or HI11-P1/P3Zcan only be fitted to left
P1-.../Z, .../V, .../I2, .../ST, .../IVS +N-P1Z000416
1 off N-P1Z000652
P3-.../E, .../EA... – N-P3E062432
The neutral contact is always early-make and late-break.
Switching capacity of N-P3... equivalent to P3-100... contacts
P3-.../Z, .../V, .../IVS P3-63/E, .../Z, .../I4, .../STP3-100/E, .../Z, .../I5, .../ST
+N-P3Z009036
1 off N-P3Z064805
Auxiliary contacts
1 make contact, 1 break contact
Can be fitted to left and/or right of 3-pole P switch-disconnectors P1-.../E, .../EA..., .../EZ P3-.../E, .../EA
+HI11-P1/P3E064100
1 off HI11-P1/P3E061813
5 off The make contact is always connected as a load-shedding contact, i.e. late-make, early-break.
With P1-.../I2:HI11-P1/P3Z or N-P1Z can be fitted to left only
P1-.../Z, .../V, .../I2, .../ST, .../IVS P3-63/Z, .../V, .../I4, .../ST, .../IVSP3-100/Z, .../V, .../I5, .../ST, .../IVS
+HI11-P1/P3Z064526
1 off HI11-P1/P3Z062031
5 off
Centre mounting accessories
For single-hole fittingMounting diameter 22.3 mm
With front plate T0-.../E, T3-.../E +EZ-T0001750
1 off EZ-T0081622
1 off Rapid snap-fitting in panel sides, plates and doors.Legend plates from the RMQ range of control circuit devices can be used.Without front plate
For engraved front platesT0-.../E, T3-.../E +EZ/OFS-T0
0017511 off EZ/OFS-T0
0018691 off
Mounting diameter 22.3 mm and 30.5 mm T0-.../E, T3-.../E, P1-.../E +EZ-P1026222
1 off EZ-P1091455
5 off Screw fixing enables one person to fit the equipment into panel sides, plates and doors.Legend plates from the RMQ range of control circuit devices can be used.
Service distribution board mounting accessoriesIncludes push-fit shaft T0-.../XZ +IVS-T0
0454721 off IVS-T0
0911141 off Use the front plate of the basic switch
For retrofitting T0-.../XZ basic switches as T0-.../IVS into service distribution boards
07/064 07/065
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type suffix Price Type PriceArticle no. See Price
ListStd. pack Article no. See Price
ListStd. pack
When orderedwith basic unit
When ordered separately
Coupling drive
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../Z
– DE-T0093487
1 off
For conversion of T5 (B)-.../E flush mounting switchinto a rear mounting switchSpare parts for T5(B)/(P3)-.../Z
– DE-P3093972
3 off
Interlock sections
With PE and N conductor connection T0-.../E, .../EZ T3-.../E, .../EZ P1-.../E, .../EZ
+UV-T0038519
1 off UV-T0019925
1 off Fits on the reverse of flush mounting switches
T5(B)-.../E P3-.../E
+UV-P3030402
1 off UV-P3048289
1 off
For cover or door interlockWith PE and N conductor connection
T0-.../Z T3-.../Z P1-.../Z
+UV-T0038519
1 off UV-T0019925
1 off With interlocking function for rear mounting switches
T5(B)-.../Z P3-.../Z
+UV-P3030402
1 off UV-P3048289
1 off
Interlock extensions1) Up to four off, 25 mm each, can be plugged onto interlock section(An equal number of shaft extensions is required for this purpose)
UV-T0 +ZVV-T0024662
1 off ZVV-T0022298
10 off Notes relating to installation in enclosures
a Page 07/089UV-P3 +ZVV-P3
0243791 off ZVV-P3
02467110 off
Shaft extensionsUp to four off, 25 mm each,can be plugged onto switch shaft
T0-.../Z T3-.../Z P1-.../Z
+ZAV-T0023736
1 off ZAV-T0027044
10 off Notes relating to installation in enclosures
a Page 07/089
T5(B)-.../Z P3-.../Z
+ZAV-P3026623
1 off ZAV-P3029417
10 off
Notes 1) Use ZVV-T0 only with T0/T3-.../Z and P1-.../Z Use ZVV-P3 only with T5(B)-.../Z and P3-.../Z
07/066 07/067
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type suffix Price Type PriceArticle no. See Price
ListArticle no. See Price
ListStd. pack
When orderedwith basic unit
When ordered separately
Sleeves/coversFor flush-mounting switches with up to 4 contact units T0-.../E
T3-.../E P1-.../E
– H3-T0093828
1 off Cable entriesQuantity:
2
x
o 20 mm+ 2
x
o 15 mmCross-section: 5
x 6 mm2 5
x 2.5 mm2
Cover for protection of terminalsFor up to 2 contact units
T5(B)-.../E, .../Z – H1-T5045062
1 off Can be used for input and/or output wiring
Extension of H1-T5 coverTo protect 3 to 8 contact units
H1-T5 – HZ-T5045063
10 off 1
x HZ-T5 required per contact unit
To cover terminals on3-pole switch-disconnectors
P1-.../E, .../EZ, .../Z, .../EA, .../V – H-P1017253
5 off Can be used for input and/or output wiring
P1-...N, ...HI11, ...N...HI11 – H-P14019626
5 off
To cover terminals on3-pole open switch-disconnectors with N neutral conductor and/or HI11 auxiliary contact modules fitted
P3-.../E, .../Z, .../EA, .../V P3-...N, ...HI11, ...N...HI11
– H-P3021999
5 off The shroud is designed for fitting onto both sides of the switch-disconnector. Parts which are not required can be broken off.
Cover assembly to protect the 6 terminals T6-160-6/... – H-T6-160200183
1 off
Cover assembly to protect the 6 terminals T8-3-8342/... – H-T8200184
1 off
07/068 07/069
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/070
For use with Type PriceArticle no. See Price
ListStd. pack
Insulated enclosures, IP65Enclosures designed for metric cable glands to EN 50 262
1 – 2 contact units T0-.../XZ CI-K1-T0-2207435
1 off Cable sizes which may be pushed through the diaphragm
3 – 4 contact units T0-.../XZ CI-K1-T0-4207436 Type Main-/control current
1 – 2 contact units T3-.../XZ CI-K2-T3-2207437
Cl-K1-T0-...Cl-K2-T3-...
12 mm16 mm
–8 mm
3 – 4 contact units T3-.../XZ CI-K2-T3-4225325
5 contact units T3-.../Z CI-K2-T3-5207438
1 – 2 contact units T5B-.../E CI-K4-T5B-2207439
3 – 4 contact units T5B-.../Z CI-K4-T5B-4207440
1 – 2 contact units T5-.../Z CI-K5-T5-2207441
Converts T5-.../Z into T5-.../I5 and T5B-.../E into T5B.../I4:Order AW-T5-... extension terminals in addition
a Page 07/0713 – 4 contact units T5-.../Z CI-K5-T5-4
207442
Neutral terminals
For connection of 5th conductor T0-.../I1, Cl-K1-T0-...T3-.../I2, Cl-K2-T3-...P1-.../I2
K-CI-K1/2207451
20 off
T5B-.../I4, Cl-K4-T5B-...P3-.../I4
K-CI-K4206916
20 off
T5-.../I5, Cl-K5-T5-...P3-.../I5
K-CI-K5218488
1 off
Set of external fixing bracketsT5B-.../I4, T5-.../I5,P3-63/I4, P3-100/I5,
AB-CI-K4/5206914
1 off For fixing CI-K4 and CI-K5 directly to the wallOne set comprises 4 brackets
Metric diaphragm grommets
• IP65• With integral push-through diaphragm
External cable diametermm
Cable entry Hole diametermm
H03VV-F 3
x 0.75 mm², NYM 5
x 1.5/5
x 2.5 mm²KT-M20207602
100 off 1 – 13 M20 20.5
H03VV-F 3
x 0.75 mm², NYM 4
x 10 mm²KT-M25207603
1 – 18 M25 25.5
H03VV-F 3
x 0.75 mm², NYM 4
x 16/5
x 10 mm²KT-M32207604
1 – 24 M32 32.5
Metric cable glands to EN 50 262
• With lock nut and integral cable clamp• IP68 up to 5 bar, halogen free
H05VV-F 4
x 2.5/3
x 4 mm², NYM 5
x 1.5/5
x 2,5 mm²V-M20206910
20 off 6 – 13 M20 20.5
H05VV-F 5
x 2.5/5
x 4 mm², NYM 5
x 2.5/5
x 6 mm²V-M25206911
20 off 9 – 17 M25 25.5
NYM 5
x 10 mm² V-M32206912
10 off 13 – 21 M32 32.5
NYM 5
x 16 mm² V-M32G226156
10 off 18 – 25 M32 32.5
NYM 4
x 35/5
x 25 mm² V-M50206913
5 off 18 – 35 M50 50.5
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/071Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsAccessories
For use with Type PriceArticle no. See Price
ListStd. pack
Set of extension terminalsFor cable connection in the enclosure
For the lowest contact unit T5B-.../I4 T5-.../I5
AW-T5-1/2032601
1 off Included with T5B-.../I4 and T5-.../I5 as standardFit T5(B) with extension terminals to install it as T5(B)-.../E in an insulated enclosure.
For the second contact unit from the bottom T5-.../I5 AW-T5-3/4032602
1 off
Indicator lights, conical, BA9sFor fitting in M20/M25 pre-mouldings in the enclosure baseFor filament bulbs and neon bulbs up to 2.4 W
a Page 02/040
Colour: red P1-.../I2, P3-.../I..., T...-.../I...
L-R208689
5 off
Colour: white L-W208692
Colour: green L-G208690
Colour: yellow L-Y208691
Set of adapter ringsTo allow PG cable glands to be used in metric cable entries
M25-PG16218923
1 set 1 set = 50 off
M32-PG21218924
1 set = 25 off
M40-PG29218925
1 set = 10 off
M50-PG36218926
1 set = 10 off
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesSystem Overview
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/072
TM On-Off switches
TM control switches
1
2
5
3
4
4
4
66
6
7
8
8
8
8
9
8
9
10
8
AUTO
HAND
O
2
11
3
4
5
66
6 4
4
9
9
10
1
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/073Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesSystem Overview
Flush mounting (.../E) 1Front IP65Fitting from rear in panel sides, platesor doorsTerminal:Pozidriv screwFinger-proof
a Page 07/074
Flush mountingcontrol circuit isolators (.../E/SVB)
1
Front IP65To IEC/EN 60 947-5Lockable in 0 (Off) position using two padlocks, 4 mm ∅ or 1 padlock, 6 mm ∅Can be used at up to 250 V AC per contactUp to 6 contacts admissible
a Page 07/074
Product attributes
Contact chamber• Rated uninterrupted current 10 A• Gold-plated contacts for safe switching
of extra low voltages and currentseven in corrosive atmospheres
• Positively opening contacts• 1 – 2 contacts per contact chamber,
up to 16 contacts per switch• Switching of differing potentials• Control circuit reliability
Centre mounting (.../EZ) 2Front IP65Mounting in a standard 16.2 mm aperture, or in 22.3 mm to IEC/EN 60 947-5-1 following removal of supplied adapterM22-ST... legend plate mounts from the RMQ control circuit range can be used for marking(see Page 02/027)
a Page 07/074
Key operation for centre mounting 3, 42 keys are suppliedOption for key withdrawal at 90° with KABA micro cylinder lockOption for key withdrawal at 60° withRONIS cylinder lockAlways state the position in which the key is to be withdrawable
a Page 07/083
Circuit diagrams (examples)
Switch position 1:Contact 1 – 2 open,Contact 3 – 4 closed.
Switching from 1 to 2:Contact 1 – 2 early-make,Contact 3 – 4 late-break.
Switching from 2 to 3:Contact 1 – 2 opens briefly.
Switching from 3 to 4:Contact 1 – 2 remains closed.
1
2
3
4Terminal marking
Link
0
1
2
Contact open
Contact closed
Switch position
1
2
3
4
0
1
2
3
4
Centre mounting switches, standard 5, 6Black thumb-grip and silver-coloured front plate
a Page 07/074
Control circuit isolators 7, 8Red rotary handle and yellow locking collarBlack rotary handle and black locking collarLockable in the 0 (Off) position
a Page 07/074
Flush mounting switches, standard 9, 10Black thumb-grip and silver-coloured front plate
a Page 07/074
Standard switches for distribution board mounting (.../IVS)
11
Mounting in service distribution boardsMounting width: 2 space units(45 mm mounting depth)Up to 2 contact units
a Page 07/074
Switch position• Reliable switching due to indexing
mechanism
• Switching angles 30°, 45°, 60°, 90°• Automatic return with up to
6 contacts• Complete rotation• Switching angle of 360°
allows complete rotation in both directions
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Circuit Isolators, On-Off Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/074
Circuit diagram Front plate no.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Service distribution board mountingFront IP30
Type Price Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
List
Control circuit isolators, 90°
With padlocking facility, lockable in the Off positionUp to 250 V AC per contact
1 TM-1-8290/E/SVB045477
– –
TM-1-8290/E/SVB-SW215351
– –
2 TM-1-8291/E/SVB045478
– –
TM-1-8291/E/SVB-SW215352
– –
3 TM-2-8292/E/SVB045484
– –
TM-2-8292/E/SVB-SW210955
– –
3+N TM-2-8293/E/SVB045485
– –
TM-2-8293/E/SVB-SW215353
– –
6 TM-3-8326/E/SVB045498
– –
TM-3-8326/E/SVB-SW215354
– –
On-Off switches, 90°1 TM-1-8290/E
070131TM-1-8290/EZ000693
TM-1-8290/IVS225334
2 TM-1-8291/E072504
TM-1-8291/EZ015073
TM-1-8291/IVS225335
3 TM-2-8292/E074877
TM-2-8292/EZ015096
TM-2-8292/IVS225336
3+N TM-2-8293/E077250
TM-2-8293/EZ045486
TM-2-8293/IVS225337
6 TM-3-8326/E079623
TM-3-8326/EZ045499
–
Standard pack: 1 off
01
2
1
01
2
1
4
3
01
2
1 3
4
5
6
01
2
1 3
4
5
6
7
8
2
1 3
4
5
6
7
8
9
10
11
1201
2
1
01
1
0
F 056
2
1 3
4
01
1
0
F 056
2
1 3
4
5
6
01
1
0
F 056
2
1 3
4
5
6
7
8
01
1
0
F 056
2
1 3
4
5
6
7
8
9
10
11
1201
1
0
F 056
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/075Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Changeover Switches
Circuit diagram Front plate no.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Service distribution board mountingFront IP30
Type Price Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
List
Changeover switches without 0 (Off) position, 60°1 TM-1-8220/E
081996TM-1-8220/EZ000692
TM-1-8220/IVS225338
2 TM-2-8221/E084369
TM-2-8221/EZ015197
TM-2-8221/IVS225339
3 TM-3-8222/E086742
TM-3-8222/EZ045493
–
4 TM-4-8223/E089115
TM-4-8223/EZ046119
–
5 TM-5-8369/E091488
TM-5-8369/EZ046126
–
6 TM-6-8370/E093861
TM-6-8370/EZ046130
–
Changeover switches with 0 (Off) position, 60°1 TM-1-8210/E
096234TM-1-8210/EZ015137
TM-1-8210/IVS225340
2 TM-2-8211/E098607
TM-2-8211/EZ015166
TM-2-8211/IVS225341
3 TM-3-8212/E010807
TM-3-8212/EZ045491
–
4 TM-4-8213/E013180
TM-4-8213/EZ045847
–
Standard pack: 1 off
2
1 3
4
12 F 072
1 2
2
1 3
4
5
6
7
8
12 F 072
1 2
2
1 3
4
5
6
7
8
9
10
11
12
12 F 072
1 2
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
12 F 072
1 2
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
12 F 072
1 2
12
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23
F 072
1 2
2
1 3
4
201
F 071
1 20
2
2
1 3
4
5
6
7
8
01
F 071
1 20
2
1 3
4
5
6
7
8
9
10
11
12
102 F 249
102
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
102 F 249
102
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Changeover Switches, Hand/Auto Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/076
Circuit diagram Front plate no.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Service distribution board mountingFront IP30
Type Price Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
ListChangeover switches with 0 (Off) position, 90°
1 TM-1-8218/E015553
TM-1-8218/EZ045476
–
2 TM-2-8219/E017926
TM-2-8219/EZ045482
–
3 TM-3-8299/E020299
TM-3-8299/EZ045497
–
3+N TM-4-8294/E022672
TM-4-8294/EZ046121
–
Hand/Auto switches, 60°1 – TM-1-8220 F288/EZ
016925–
1 TM-1-15431/E025045
TM-1-15431/EZ000691
TM-1-15431/IVS225342
2 TM-2-15432/E027418
TM-2-15432/EZ016878
TM-2-15432/IVS225343
3 TM-3-15433/E029791
TM-3-15433/EZ045490
–
Changeover switches with spring-return from both directions, 30°
1 TM-1-8214/E032164
TM-1-8214/EZ016673
–
2 TM-2-8215/E034537
TM-2-8215/EZ045481
–
3 TM-3-8216/E036910
TM-3-8216/EZ045492
–
Standard pack: 1 off
2
1 3
4
201
F 057
0
1 2
2
1 3
4
5
6
7
8
201
F 057
0
1 2
2
1 3
4
5
6
7
8
9
10
11
12
201
F 057
0
1 2
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
201
F 057
0
1 2
2
1 3
4
AUTOHAND
F 288
HAND AUTOM
2
1 3
4
HAND
AUTO0 F 085
0HAND AUTO
0AUTO
HAND
2
1 3
4
5
6
7
8
F 085
0HAND AUTO
AUTO
HAND0
2
1 3
4
5
6
7
8
9
10
11
12
F 085
0HAND AUTO
2
1 3
4
102 F 025
01 2
2
1 3
4
5
6
7
8
102 F 025
01 2
2
1 3
4
5
6
7
8
9
10
11
12
102 F 025
01 2
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/077Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Step Switches
Circuit diagram Front plate no.
No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Service distribution board mountingFront IP30
Type Price Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListArticle no. See Price
List
Step switches without 0 (Off) position, 60°3 steps
1 TM-2-8230/E039283
TM-2-8230/EZ000701
TM-2-8230/IVS225344
3 TM-5-8270/E041656
TM-5-8270/EZ046124
4 steps1 TM-2-8231/E
044029TM-2-8231/EZ000700
TM-2-8231/IVS225345
3 TM-6-8271/E046402
TM-6-8271/EZ046128
Standard pack: 1 off
2
1 3
4
5
6
321
F 076
2
1
3
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17
18
321
F 076
2
1
3
2
1 3
4
5
6
7
8
1234
F 077
2
1
3
4
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23
1234
F 077
2
1
3
4
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Step Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/078
Circuit diagram Front plate no. No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
List
Step switches without 0 (Off) position 5 steps, 60°
1 TM-3-8232/E039298
TM-3-8232/EZ015592
2 TM-5-8252/E041671
TM-5-8252/EZ046123
6 steps, 60°
Without complete rotation1 TM-3-8233/E
053521TM-3-8233/EZ015630
2 TM-6-8253/E055894
TM-6-8253/EZ046127
10 steps, 30°1 TM-5-8237/E
069150TM-5-8237/EZ015661
Standard pack: 1 off
321
45
2
1 3
4
5
6
7
8
9
10
F 078
2
1
3
4
5
321
45
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
F 078
2
1
3
4
5
2
1 3
4
5
6
7
8
9
10
11
12
321
456
21
34
56
F 079
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23
321
456
21
34
56
F 079
321
45678 9
10
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
F 011
12
3 4 567
8910
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/079Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Step Switches
Circuit diagram Front plate no. No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
List
Step switches with additional 0 (Off) position2 steps, 60°
1 TM-1-8240/E058267
TM-1-8240/EZ015226
2 TM-2-8260/E060640
TM-2-8260/EZ045483
3 TM-3-8280/E063013
TM-3-8280/EZ045496
3 steps, 45°1 TM-2-8241/E
065386TM-2-8241/EZ015256
2 TM-3-8261/E067759
TM-3-8261/EZ000698
3 TM-5-8281/E070132
TM-5-8281/EZ046125
4 steps, 30°1 TM-2-8242/E
072505TM-2-8242/EZ015506
2 TM-4-8262/E074878
TM-4-8262/EZ046120
3 TM-6-8282/E077251
TM-6-8282/EZ046129
Standard pack: 1 off
2
1 3
4
210
F 075
1
0
2
2
1 3
4
5
6
7
8
210
F 075
1
0
2
2
1 3
4
5
6
7
8
9
10
11
12
210
F 075
1
0
2
2
1 3
4
5
6
3210 F 109
0
1 2 3
2
1 3
4
5
6
7
8
9
10
11
12
3210 F 109
0
1 2 3
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17
18
3210 F 109
0
1 2 3
2
1 3
4
5
6
7
8
1234
0 F 002
01
2 3 4
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
1234
0 F 002
01
2 3 4
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17 19
2018
21
22 24
23
1234
0 F 002
01
2 3 4
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Step Switches, Group Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/080
Circuit diagram Front plate no. No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
List
Step switches with additional 0 (Off) position, 30°5 steps
1 TM-3-8243/E079624
TM-3-8243/EZ015537
6 steps1 TM-3-8244/E
081997TM-3-8244/EZ045495
9 steps1 TM-5-8247/E
009741TM-5-8247/EZ015565
Group switches2 groups, 60°
1 TM-1-8310/E084370
TM-1-8310/EZ045479
3 groups, 30°1 TM-2-8311/E
086743TM-2-8311/EZ045487
Standard pack: 1 off
2
1 3
4
5
6
7
8
9
10
321
45
0 F 003
12 3 4
50
2
1 3
4
5
6
7
8
9
10
11
12
321
45
0
6
F 004
12 3 4
560
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
17
18
210
3456789
F 007
01
2 3 4567
89
2
1 3
4
210
F 075
1
0
2
2
1 3
4
5
6
210
3F 001
12 3
0
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/081Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: On/Off Switches, Spring-Return
Circuit diagram Front plate no. No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
List
On/Off switches with spring-return, 30°Off switches, spring-return
1 TM-1-8174/E089116
TM-1-8174/EZ016646
On switches, spring-return1 TM-1-8175/E
091489TM-1-8175/EZ015690
On-Off switches, spring-return1 TM-1-8176/E
093862TM-1-8176/EZ016714
2 TM-2-8183/E096235
TM-2-8183/EZ045480
On-Off spring-return switches, 90°/30°With spring-return from START to 1
1 TM-1-8178/E098608
TM-1-8178/EZ016786
Standard pack: 1 off
2
1
STOPF 022
STOP
2
1
START F 023
START
2
1 3
4
START
STOP F 024
STOP START
2
1 3
4
5
6
7
8
START
STOP F 024
STOP START
2
1 3
4
START
0
1
F 119
START
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesControl Switches: Reversing Switches, Coding Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/082
Circuit diagram Front plate no. No. of poles
Flush mountingFront IP65
Centre mountingFront IP65
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
List
Reversing switchesWith spring-return from Start to 1 or 2, 60°/30°
1 TM-2-8177/E010808
TM-2-8177/EZ016838
Reversing switches, 60°2 TM-2-8400/E
013181TM-2-8400/EZ045488
3 TM-3-8401/E015554
TM-3-8401/EZ045500
Reversing switches with spring-return to 0, 30°3 TM-3-8228/E
017927TM-3-8228/EZ045494
Coding switches, BCD Code 0 – 9, 30°
1 TM-2-8550/E020300
TM-2-8550/EZ000699
Complementary BCD code 0 – 9, 30°1 TM-2-8551/E
022673TM-2-8551/EZ045489
BCD code 0 – 9 + complement, 30°1 TM-4-8552/E
025046TM-4-8552/EZ046122
Standard pack: 1 off
1
20
2
1 3
4
5
6
7
8
START
START
0 21
F 121
START START
2
1 3
4
5
6
7
8
201 F 071
1 20
2
1 3
4
5
6
7
8
9
10
201 F 071
1 20
2
1 3
4
5
6
7
8
9
10
102
F 025
01 2
2
1 3
4
5
6
7
8
210
3456789
F 007
01
2 3 4567
89
2
1 3
4
5
6
7
8
210
3456789
F 007
01
2 3 4567
89
2
1 3
4
5
6
7
8
9
10
11
12
13 15
1614
210
3456789
F 007
01
2 3 4567
89
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/083Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesAccessories
Type PriceArticle no. See Price
List
Key operation1)
Includes two keysKABA lock for 90° switching angle1)
Degree of protection IP65The key can be withdrawn only in specified positions, see diagrams below. However, the KABA lock mechanism for 90° can also be used for other switching angles provided the positions for key withdrawal correspond with those specified for the Type of switch. Example: +EZ/S-B can be used on a step switch having a switching angle of 30°, provided the key is to be with-drawn only in the Off position at 270°.The key is not withdrawable in positions which exceed the total switching angle of the switch.
Options for key withdrawal
For example of position marking see
a Page 07/111
Key withdrawable at: 0° +EZ/S-A045458
270° +EZ/S-B045459
270 + 0° +EZ/S-F045463
0 + 90° +EZ/S-E045462
270 + 0 + 90° +EZ/S-R045471
270 + 0 + 90 + 180° +EZ/S-G045464
RONIS lock for 60° switching angle1)
Degree of protection IP55Key withdrawable at: 0 + 180° +EZ/S-C
045460270 + 90° +EZ/S-D
045461300 + 0 + 60 + 120 + 180 + 240° +EZ/S-H
045465270 + 330 + 30 + 90 + 150 + 210° +EZ/S-J
0454660 + 60 + 180 + 240° +EZ/S-M
045467270 + 330 + 90 + 150° +EZ/S-N
045468300 + 0 + 120 + 180° +EZ/S-P
045469270 + 30 + 90 + 210° +EZ/S-Q
045470
Standard pack: 1 off 1) For mounting forms E and EZ
A B F E R G
C D H J M N P Q
3300
30
300
270
240 225
210180
150
135 120
90
60315 45
Moeller HPL0211-2001/2002
T Rotary SwitchesT0 Non-Standard Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/084
Type Price Type Price PriceSee Price List
See Price List
See Price List
Std. pack
T0 rotary switches T0-1-SOND.../E T0-5-SOND.../E 1 off T0-1-SOND.../EA/SVB T0-5-SOND.../EZ T0-1-SOND.../EA/SVB-SW T0-5-SOND.../EZ/OFS T0-1-SOND.../EZ T0-5-SOND.../IVS T0-1-SOND.../EZ/OFS T0-5-SOND.../XZ T0-1-SOND.../I1 T0-5-SOND.../Z T0-1-SOND.../I1/SVB T0-1-SOND.../I1/SVB-SW T0-6-SOND.../E T0-1-SOND.../IVS T0-6-SOND.../EZ T0-1-SOND.../V/SVB T0-6-SOND.../EZ/OFS T0-1-SOND.../V/SVB-SW T0-6-SOND.../IVS T0-1-SOND.../XZ T0-6-SOND.../XZ T0-1-SOND.../Z T0-6-SOND.../Z
T0-2-SOND.../E T0-7-SOND.../E T0-2-SOND.../EA/SVB T0-7-SOND.../EZ T0-2-SOND.../EA/SVB-SW T0-7-SOND.../EZ/OFS T0-2-SOND.../EZ T0-7-SOND.../IVS T0-2-SOND.../EZ/OFS T0-7-SOND.../XZ T0-2-SOND.../I1 T0-7-SOND.../Z T0-2-SOND.../I1/SVB T0-2-SOND.../I1/SVB-SW T0-8-SOND.../E T0-2-SOND.../IVS T0-8-SOND.../EZ T0-2-SOND.../V/SVB T0-8-SOND.../EZ/OFS T0-2-SOND.../V/SVB-SW T0-8-SOND.../IVS T0-2-SOND.../XZ T0-8-SOND.../XZ T0-2-SOND.../Z T0-8-SOND.../Z
T0-3-SOND.../E T0-9-SOND.../E T0-3-SOND.../EA/SVB T0-9-SOND.../EZ T0-3-SOND.../EA/SVB-SW T0-9-SOND.../EZ/OFS T0-3-SOND.../EZ T0-9-SOND.../IVS T0-3-SOND.../EZ/OFS T0-9-SOND.../XZ T0-3-SOND.../I1 T0-9-SOND.../Z T0-3-SOND.../I1/SVB T0-3-SOND.../I1/SVB-SW T0-10-SOND.../E T0-3-SOND.../IVS T0-10-SOND.../EZ T0-3-SOND.../V/SVB T0-10-SOND.../EZ/OFS T0-3-SOND.../V/SVB-SW T0-10-SOND.../IVS T0-3-SOND.../XZ T0-10-SOND.../XZ T0-3-SOND.../Z T0-10-SOND.../Z
T0-4-SOND.../E T0-11-SOND.../E T0-4-SOND.../EA/SVB T0-11-SOND.../EZ T0-4-SOND.../EA/SVB-SW T0-11-SOND.../EZ/OFS T0-4-SOND.../EZ T0-11-SOND.../IVS T0-4-SOND.../EZ/OFS T0-11-SOND.../XZ T0-4-SOND.../I1 T0-11-SOND.../Z T0-4-SOND.../I1/SVB T0-4-SOND.../I1/SVB-SW T0-4-SOND.../IVS T0-4-SOND.../V/SVB T0-4-SOND.../V/SVB-SW T0-4-SOND.../XZ T0-4-SOND.../Z
Notes These Pages show T rotary switches with non-
standard contact sequences (-SOND...) which are priced accordingly (See Price List). Use the Initial Order form on
a Page 07/112 for ordering any T rotary switch combination.
For subsequent orders, state contact sequence number together with country identifer (eg 4711GB)
The contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000.
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/085Moeller HPL0211-2001/2002
T Rotary SwitchesT3 Non-Standard Switches
Type Price Type PriceSee Price List
See Price List
Std. pack
T3 rotary switches T3-1-SOND.../E T3-5-SOND.../E 1 off T3-1-SOND.../EA/SVB T3-5-SOND.../EA/SVB T3-1-SOND.../EA/SVB-SW T3-5-SOND.../EA/SVB-SW T3-1-SOND.../EZ T3-5-SOND.../EZ T3-1-SOND.../EZ/OFS T3-5-SOND.../EZ/OFS T3-1-SOND.../I2 T3-5-SOND.../I2 T3-1-SOND.../I2/SVB T3-5-SOND.../I2/SVB T3-1-SOND.../I2/SVB-SW T3-5-SOND.../I2/SVB-SW T3-1-SOND.../V/SVB T3-5-SOND.../V/SVB T3-1-SOND.../V/SVB-SW T3-5-SOND.../V/SVB-SW T3-1-SOND.../XZ T3-5-SOND.../XZ T3-1-SOND.../Z T3-5-SOND.../Z
T3-2-SOND.../E T3-6-SOND.../E T3-2-SOND.../EA/SVB T3-6-SOND.../EA/SVB T3-2-SOND.../EA/SVB-SW T3-6-SOND.../EA/SVB-SW T3-2-SOND.../EZ T3-6-SOND.../EZ T3-2-SOND.../EZ/OFS T3-6-SOND.../EZ/OFS T3-2-SOND.../I2 T3-6-SOND.../V/SVB T3-2-SOND.../I2/SVB T3-6-SOND.../V/SVB-SW T3-2-SOND.../I2/SVB-SW T3-6-SOND.../XZ T3-2-SOND.../V/SVB T3-6-SOND.../Z T3-2-SOND.../V/SVB-SW T3-2-SOND.../XZ T3-7-SOND.../E T3-2-SOND.../Z T3-7-SOND.../EZ
T3-7-SOND.../EZ/OFS T3-3-SOND.../E T3-7-SOND.../XZ T3-3-SOND.../EA/SVB T3-7-SOND.../Z T3-3-SOND.../EA/SVB-SW T3-3-SOND.../EZ T3-8-SOND.../E T3-3-SOND.../EZ/OFS T3-8-SOND.../EZ T3-3-SOND.../I2 T3-8-SOND.../EZ/OFS T3-3-SOND.../I2/SVB T3-8-SOND.../XZ T3-3-SOND.../I2/SVB-SW T3-8-SOND.../Z T3-3-SOND.../V/SVB T3-3-SOND.../V/SVB-SW T3-9-SOND.../E T3-3-SOND.../XZ T3-9-SOND.../EZ T3-3-SOND.../Z T3-9-SOND.../EZ/OFS
T3-9-SOND.../XZ T3-4-SOND.../E T3-9-SOND.../Z T3-4-SOND.../EA/SVB T3-4-SOND.../EA/SVB-SW T3-10-SOND.../E T3-4-SOND.../EZ T3-10-SOND.../EZ T3-4-SOND.../EZ/OFS T3-10-SOND.../EZ/OFS T3-4-SOND.../I2 T3-10-SOND.../XZ T3-4-SOND.../I2/SVB T3-10-SOND.../Z T3-4-SOND.../I2/SVB-SW T3-4-SOND.../V/SVB T3-11-SOND.../E T3-4-SOND.../V/SVB-SW T3-11-SOND.../EZ T3-4-SOND.../XZ T3-11-SOND.../EZ/OFS T3-4-SOND.../Z T3-11-SOND.../XZ
T3-11-SOND.../Z
Moeller HPL0211-2001/2002
T Rotary SwitchesT5B Non-Standard Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/086
Type Price Type PriceSee Price List
See Price List
Std. pack
T5B rotary switches T5B-1-SOND.../E T5B-5-SOND.../E 1 off T5B-1-SOND.../EA/SVB T5B-5-SOND.../EA/SVB T5B-1-SOND.../EA/SVB-SW T5B-5-SOND.../EA/SVB-SW T5B-1-SOND.../I4 T5B-5-SOND.../V/SVB T5B-1-SOND.../I4/SVB T5B-5-SOND.../V/SVB-SW T5B-1-SOND.../I4/SVB-SW T5B-5-SOND.../X T5B-1-SOND.../V/SVB T5B-5-SOND.../Z T5B-1-SOND.../V/SVB-SW T5B-1-SOND.../X T5B-6-SOND.../E T5B-1-SOND.../Z T5B-6-SOND.../EA/SVB
T5B-6-SOND.../EA/SVB-SW T5B-2-SOND.../E T5B-6-SOND.../V/SVB T5B-2-SOND.../EA/SVB T5B-6-SOND.../V/SVB-SW T5B-2-SOND.../EA/SVB-SW T5B-6-SOND.../X T5B-2-SOND.../I4 T5B-6-SOND.../Z T5B-2-SOND.../I4/SVB T5B-2-SOND.../I4/SVB-SW T5B-7-SOND.../E T5B-2-SOND.../V/SVB T5B-7-SOND.../EA/SVB T5B-2-SOND.../V/SVB-SW T5B-7-SOND.../EA/SVB-SW T5B-2-SOND.../X T5B-7-SOND.../V/SVB T5B-2-SOND.../Z T5B-7-SOND.../V/SVB-SW
T5B-7-SOND.../X T5B-3-SOND.../E T5B-7-SOND.../Z T5B-3-SOND.../EA/SVB T5B-3-SOND.../EA/SVB-SW T5B-8-SOND.../E T5B-3-SOND.../I4 T5B-8-SOND.../EA/SVB T5B-3-SOND.../I4/SVB T5B-8-SOND.../EA/SVB-SW T5B-3-SOND.../I4/SVB-SW T5B-8-SOND.../V/SVB T5B-3-SOND.../V/SVB T5B-8-SOND.../V/SVB-SW T5B-3-SOND.../V/SVB-SW T5B-8-SOND.../X T5B-3-SOND.../X T5B-8-SOND.../Z T5B-3-SOND.../Z
T5B-9-SOND.../E T5B-4-SOND.../E T5B-9-SOND.../X T5B-4-SOND.../EA/SVB T5B-9-SOND.../Z T5B-4-SOND.../EA/SVB-SW T5B-4-SOND.../I4 T5B-10-SOND.../E T5B-4-SOND.../I4/SVB T5B-10-SOND.../X T5B-4-SOND.../I4/SVB-SW T5B-10-SOND.../Z T5B-4-SOND.../V/SVB T5B-4-SOND.../V/SVB-SW T5B-4-SOND.../X T5B-4-SOND.../Z
Notes These Pages show T rotary switches with non-standard contact sequences (-SOND...) which are priced accordingly (See Price List). Use the Initial Order form on
a Page 07/112 for ordering any T rotary switch combination.
For subsequent orders, state contact sequence number together with country identifer (eg 4711GB)
The contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000.
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/087Moeller HPL0211-2001/2002
T Rotary SwitchesT5 Non-Standard Switches
Type Price Type PriceSee Price List
See Price List
Std. pack
T5 rotary switches T5-1-SOND.../E T5-5-SOND.../E 1 off T5-1-SOND.../EA/SVB T5-5-SOND.../EA/SVB T5-1-SOND.../EA/SVB-SW T5-5-SOND.../EA/SVB-SW T5-1-SOND.../I5 T5-5-SOND.../V/SVB T5-1-SOND.../I5/SVB T5-5-SOND.../V/SVB-SW T5-1-SOND.../I5/SVB-SW T5-5-SOND.../X T5-1-SOND.../V/SVB T5-5-SOND.../Z T5-1-SOND.../V/SVB-SW T5-1-SOND.../X T5-6-SOND.../E T5-1-SOND.../Z T5-6-SOND.../EA/SVB
T5-6-SOND.../EA/SVB-SW T5-2-SOND.../E T5-6-SOND.../V/SVB T5-2-SOND.../EA/SVB T5-6-SOND.../V/SVB-SW T5-2-SOND.../EA/SVB-SW T5-6-SOND.../X T5-2-SOND.../I5 T5-6-SOND.../Z T5-2-SOND.../I5/SVB T5-2-SOND.../I5/SVB-SW T5-7-SOND.../E T5-2-SOND.../V/SVB T5-7-SOND.../EA/SVB T5-2-SOND.../V/SVB-SW T5-7-SOND.../EA/SVB-SW T5-2-SOND.../X T5-7-SOND.../V/SVB T5-2-SOND.../Z T5-7-SOND.../V/SVB-SW
T5-7-SOND.../X T5-3-SOND.../E T5-7-SOND.../Z T5-3-SOND.../EA/SVB T5-3-SOND.../EA/SVB-SW T5-8-SOND.../E T5-3-SOND.../I5 T5-8-SOND.../EA/SVB T5-3-SOND.../I5/SVB T5-8-SOND.../EA/SVB-SW T5-1-SOND.../I5/SVB-SW T5-8-SOND.../V/SVB T5-3-SOND.../V/SVB T5-8-SOND.../V/SVB-SW T5-3-SOND.../V/SVB-SW T5-8-SOND.../X T5-3-SOND.../X T5-8-SOND.../Z T5-3-SOND.../Z
T5-9-SOND.../E T5-4-SOND.../E T5-9-SOND.../X T5-4-SOND.../EA/SVB T5-9-SOND.../Z T5-4-SOND.../EA/SVB-SW T5-4-SOND.../I5 T5-10-SOND.../E T5-4-SOND.../I5/SVB T5-10-SOND.../X T5-4-SOND.../I5/SVB-SW T5-10-SOND.../Z T5-4-SOND.../V/SVB T5-4-SOND.../V/SVB-SW T5-4-SOND.../X T5-4-SOND.../Z
Moeller HPL0211-2001/2002
T Rotary SwitchesTM Non-Standard Switches, Bulk Packaged Switches
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/088
Type1) Price Type2) PriceSee Price List
See Price List
Std. pack
TM mini rotary switches
TM-1-SOND.../E TM-1-SOND-ERSTBESTELLUNG/E 1 off TM-1-SOND.../EZ TM-1-SOND-ERSTBESTELLUNG/EZTM-1-SOND.../IVS TM-1-SOND-ERSTBESTELLUNG/IVS TM-2-SOND.../E TM-2-SOND-ERSTBESTELLUNG/E TM-2-SOND.../EZ TM-2-SOND-ERSTBESTELLUNG/EZ TM-2-SOND.../IVS TM-2-SOND-ERSTBESTELLUNG/IVS TM-3-SOND.../E TM-3-SOND-ERSTBESTELLUNG/E TM-3-SOND.../EZ TM-3-SOND-ERSTBESTELLUNG/EZ TM-4-SOND.../E TM-4-SOND-ERSTBESTELLUNG/E TM-4-SOND.../EZ TM-4-SOND-ERSTBESTELLUNG/EZ TM-5-SOND.../E TM-5-SOND-ERSTBESTELLUNG/E TM-5-SOND.../EZ TM-5-SOND-ERSTBESTELLUNG/EZ TM-6-SOND.../E TM-6-SOND-ERSTBESTELLUNG/E TM-6-SOND.../EZ TM-6-SOND-ERSTBESTELLUNG/EZ TM-7-SOND.../E TM-7-SOND-ERSTBESTELLUNG/E TM-7-SOND.../EZ TM-7-SOND-ERSTBESTELLUNG/EZ TM-8-SOND.../E TM-8-SOND-ERSTBESTELLUNG/E TM-8-SOND.../EZ TM-8-SOND-ERSTBESTELLUNG/EZ
Notes 1) For subsequent orders, for which the design number is known.Form FO2 is not required for these.
2) For initial orders. Form FO2 has to be completed and submitted for these.
Type PriceArticle no. See Price
ListStd. pack
Bulk packaged switches
T0-2-1/EA/SVB-GVP50217168
50 off
P1-25/EA/SVB-GVP50217370
50 off
P1-32/EA/SVB-GVP50217169
50 off
P3-63/EA/SVB-GVP25218130
25 off
P3-100/EA/SVB-GVP25218132
25 off
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/089Moeller HPL0211-2001/2002
T Rotary SwitchesFitting Rotary Switches with Coupling (T.../Z or T.../V/SVB) into Enclosures
Notes
CI-K... insulated enclosures are enclosures specifically designed for the installation of rotary switches, such as T0, T5B and T5 with up to 4 contact units = 8 contacts, T3 with up to 5 contact units = 10 contacts. They have a high degree of protection and up to 5 cable entries. If more than 5 cables or large cross-section cables are to be connected, then we recommend the use of insulated enclosures from the CI System.
1) Select the required switch and determine the cables to be connected.
2) Select an enclosure (
a HPL0214-2001) according to the minimum mounting depth of the switch. This depth dimension has to be less than or equal to the internal mounting depth of the enclosure. In addition, the quantity and size of the cable entries must be taken into account.
Use the tables below to determine whether, and if so how many, ZAV-... shaft extensions are required and, for .../SVB switches, the identical quantity of ZVV-... interlock extensions.
Example:Switch:T3-6-.../V/SVBMinimum mounting depth:T...-6/Z = 147 mmExtensions:No extension is required for an enclosure having a mounting depth of 150 mm. Two ZAV-T0 shaft extensions and two ZVV-T0 interlock extensions are required for an enclosure having a mounting depth of 200 mm.
T0-...mounting depths
T3-...mounting depths
T5(B)-...mounting depths
Dimensions in mmWith extension Without/ With ZAV-T0 Without/ With ZAV-T0 Without/ With ZAV-P3Number +1 +2 +3 +4 +1 +2 +3 +4 +1 +2 +3 +4Switch type From To To To To To From To To To To To From To To To To ToT...-1-.../Z(V/SVB) 86 102 127 152 177 202 89 105 130 155 180 205 92 107 132 157 182 207T...-2-.../Z(V/SVB) 96 112 137 162 187 212 101 116 141 166 191 216 109 124 149 174 199 224T...-3-.../Z(V/SVB) 105 121 146 171 196 221 112 128 153 178 203 228 125 140 165 190 215 240T...-4-.../Z(V/SVB) 115 131 156 181 206 231 124 139 164 189 214 239 142 157 182 207 232 257T...-5-.../Z(V/SVB) 124 140 165 190 215 240 135 151 176 201 226 251 158 173 198 223 248 273T...-6-.../Z(V/SVB) 134 150 175 200 225 250 147 162 187 212 237 262 175 190 215 240 265 290T...-7-.../Z(V/SVB) 143 159 184 209 234 259 158 174 199 224 249 274 191 206 231 256 281 306T...-8-.../Z(V/SVB) 153 169 194 219 244 269 170 185 210 235 260 285 208 223 248 273 298 323T...-9-.../Z(V/SVB) 162 178 203 228 253 278 181 197 222 247 272 297 224 239 264 289 314 339T...-10-.../Z(V/SVB) 172 188 213 238 263 288 193 208 233 258 283 308 241 256 281 306 331 356T...-11-.../Z(V/SVB) 181 197 222 247 272 279 204 220 245 270 295 320
Moeller HPL0211-2001/2002
T Rotary SwitchesTechnical Data
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/090
T0-... T3-... T5B-... T5-... T6-...(T6-160-6)
T8-...
General technical dataStandards IEC/EN 60 947, IEC/EN 60 204, CSA, UL
Switch-disconnector to IEC/EN 60 947-3Load-break switch to IEC/EN 60 947-3Shipping classifications
a SK0200-1043Lifespan, mechanicalMax. operating frequency
OperationsOps./h
> 106
30005
x 105
30005
x 105
30005
x 105
3000> 105
50> 105
50 Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50 −25/+50 −25/+50 −25/+50 −25/+50 −25/+50
Enclosed Min./Max. °C −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40Mounting position As requiredDimensions
a Page 07/096
a Page 07/101
a Page 07/103Weight
a Page 15/023Mechanical shock resistance (shock duration 20 ms) g > 15 > 15 4) > 15 > 15 > 15 –ContactsRated operational voltage
Ue V AC 690 690 690 690 690 690Rated impulse withstand voltage
Uimp V 6000 6000 6000 6000 6000 (8000)2) 8000Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3Rated uninterrupted current
Iu with max. cable connected A 20 32 63 1005) 125 (160)2) 3156)
Load-carrying capacity in intermittent operation, Class 12, AB 60/40/25
% DF 1.3/1.6/2
x
Ie
Short-circuit rating maximum fuse A gG/gL 20 25 80 100 200 (160)2) 315
Rated short-time withstand current (1 s current)
Icw Arms 320 650 1300 1850 2000 (3000)2) 4200Safe isolation to IEC 536 between the contacts V AC 440 440 440 440 – –
Protection against direct contact Finger and back-of-hand proofto IEC 536
– –
Switching angles 90°/60°/45°/30° 90°/60° 60° (90°)3
Contact units Max. 11 11 10 10 3 3Double-break contacts Max. 22 22 20 20 6 6Current heat loss per contact at
Ie W 0.6 1.1 4.5 7.5 11 11Terminal capacitySolid or stranded1) mm2 1
x
(1 – 2.5)1
x
(1 – 6)1
x
(2.5 – 35)1
x
(2.5 – 35)1
x 70 (95)2) 150
mm2 2
x
(1 – 2.5)2
x
( 1 – 6)2
x
(2.5 – 16)2
x
(2.5 – 16)2
x 25 –
Flexible with ferrule1)
(ferrule to DIN 46 228)mm2 1
x
(0.75 – 1.5)1
x
(0.75 – 4)1
x
(1.5 – 25)1
x
(1.5 – 25)1
x 50 (50)2) 120
mm2 2
x
(0.75 – 1.5)2
x
(0.75 – 4)2
x
(1.5 – 10)2
x
(1.5 – 10)2
x 16 –
Flat conductor connection mm2 – – – – – 1 busbar25
x 53)
2 busbars20
x 33)
Terminal screw M3.5 M4 M6 M6 (counter-sunk M5)2)
M12
Max. tightening torque Nm 1 1.5 4 5.6(14)2)
25
T0-1-...toT0-4-...
T3-1-toT3-6-
T5B-... T5-... T6-...(T6-160-6)
T8-3-8342
Switch-disconnector(Main switches)Switching angles 90° 90° 90° 90° 90° 90°Max. number of switch positions 2 2 2 2 2 2Max. number of contactsfor isolating characteristics to IEC/EN 60 947
8 12 20 20 3 (6)2) 6
Isolating characteristics to IEC/EN 60 947 Up to V AC 500 500 690 690 690 690
Notes 1) T0(3), (6), (8)...: Max. 2 cross-section sizes difference admissible between 2 conductorsT5(B)-...: Max. 1 cross-section size difference admissible between 2 conductors
2) For T6-160-6/...3) For T8-3-8342/...4) T3-.../I... > 12 g5) T5-4-8344/I5: max. 95 A6) Enclosed version: max. 275 A
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/091Moeller HPL0211-2001/2002
T Rotary SwitchesTechnical Data
T0-... T3-... T5B-... T5-... T6-...(T6-160-6)
T8-...
Switching capacityAC
Rated making capacity cos
v = 0.35 A 130 320 800 950 1600 2390Rated breaking capacity 230 V AC, cos
v = 0.35 A 100 260 520 760 1280 1910Motor load switches 400 V AC, cos
v = 0.35 A 110 260 600 740 900 1800500 V AC, cos
v = 0.35 A 80 240 480 590 880 1200690 V AC, cos
v = 0.35 A 60 170 340 420 340 420AC-21A Load-break switches Rated operational current
Ie380 – 440 V, 3
hA 20 32 63 100 125 (160) 315
AC-3 Motor load switches,for operationalswitchingStar-delta valuesY
d : for star-deltaswitches without automatic spring-return
220 – 240 V, 3
h kW 3 6.5 15 18.5 22 37220 – 240 V, Y
d kW 4 11 22 30 22 37380 – 440 V, 3
h kW 4 12 22 30 37 (45) 55380 – 440 V, Y
d kW 5.5 18.5 37 45 37 (45) 55500 V, 3
h kW 5.5 15 22 37 37 37500 V, Y
d kW 7.5 22 37 55 37 37660/690 V, 3
h kW 4 15 22 30 22 37660/690 V, Y
d kW 5.5 22 37 45 22 37AC-23A Motor load switches
(main switches,maintenance switches)
220 – 240 V, 3
h kW 3.5 7.5 18.5 18.5 37 75380 – 440 V, 3
h kW 6.5 13 22 30 45 (55) 132500 V, 3
h kW 7.5 15 22 37 55 75660/690 V, 3
h kW – – 22 30 30 37AC-15 Control switches Rated operational current
Ie220 – 240/380 – 415/500 V
A 6/4/2 10/6/4 16/6/4 16/6/4 – –
DCDC-1 Load-break switches
L/R = 1 msRated operational current
Ie A 10 25 63 80 125 315
Voltage per contact pair in series
V 60 60 60 60 42 42
DC-21A 240 V A 1 (1) 1 (1) – – – –DC-23A Motor load switches
L/R = 15 ms
Figures in brackets:number of contacts to be switched in series
24 V A 10 (1) 25 (1) 50 (1) – 125 (1) 250 (1) 48 V A 10 (2) 25 (2) 50 (2) – 125 (2) 250 (2) 60 V A 10 (3) 25 (3) 50 (3) – 125 (3) 125 (3)120 V A 5 (3) 12 (3) 25 (3) – 50 (3) 50 (3)240 V A 5 (5) 10 (5) 20 (6) – – –
DC-13 Control switchesL/R = 50 ms
Rated operational current
Ie A 10 20 25 – 125 250
Voltage per contact pair in series
V 32 32 24 – 24 –
Control circuit reliability at24 V DC, 10 mA
Fault probability HF < 10−5, < 1 fault in 100000 operations
T6-160-6/...T8-3-8342/...
Auxiliary contacts
Standards Control circuit isolator to IEC/EN 60 947-5
Rated insulation voltage
Ui V AC 500Rated uninterrupted current
Iuwith max. cable connected
A 10
Rated operational current
Ie AC-15 with 220 –240/380 – 415/500 V
A 6/4/3
Short-circuit rating without welding,Max. fuse
A gG/gL 10
Terminal capacity Min. solid or flexible mm2 0.75/0.5Max. solid or flexible mm2 2.5/1.5
Max. tightening torque Nm 0.35Control circuit reliability at24 V DC, 10 mA
Fault probability HF < 10−5, < 1 fault in 100 000 operations
Moeller HPL0211-2001/2002
P Switch-DisconnectorsTechnical Data
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/092
P1-25 P1-32 P3-63 P3-100
General technical dataStandards IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA, UL
Switch-disconnector to IEC/EN 60 947-3Lifespan, mechanical Operations 3
x 105 3
x 105 105 105
Max. operating frequency Ops./h 50 50 50 50Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50 −25/+50 −25/+50 −25/+50
Enclosed Min./Max. °C −25/+40 −25/+40 −25/+40 −25/+40Mounting position As requiredDimensions
a Page 07/104Weight
a Page 15/023Mechanical shock resistance (half-sinusoidal shock 20 ms) g > 20 > 20 > 20 > 20ContactsRated operational voltage
Ue V AC 690 690 690 690Rated impulse withstand voltage Uimp V 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated uninterrupted current
Iu with max. cable connected A 25 32 63 100Load-carrying capacity in intermittent operation, Class 12, AB 60/40/25 % DF
x
Ie 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 Short-circuit rating Max. fuse A gG/gL 25 50 80 100Rated short-time withstand current (1 s current)
Icw Arms 640 640 1260 2000Isolating characteristics to IEC/EN 60 947 Up to VAC 690 690 690 690
Safe isolation to IEC 536 between the main contacts and the auxiliary contacts V AC 440 440 440 440Protection against direct contact Finger and back-of-hand proof to IEC 536
Switching angles 90° 90° 90° 90°Contacts (current paths) Max. 3(+N) 3(+N) 3(+N) 3(+N)Current heat loss per contact at
Ie W 1.1 1.8 4.5 7.5Terminal capacitySolid or stranded1) mm2 1 × (1.5 – 6) 1 × (1.5 – 6) 1 × (2.5 – 35) 1 × (2.5 – 35)
mm2 2 × (1.5 – 6) 2 × (1.5 – 6) 2 × (2.5 – 10) 2 × (2.5 – 10)Flexible with ferrule1)
(ferrule to DIN 46 228)mm2 1 × (1 – 4) 1 × (1 – 4) 1 × (1.5 – 25) 1 × (1.5 – 25)mm2 2 × (1 – 4) 2 × (1 – 4) 2 × (1.5 – 6) 2 × (1.5 – 6)
Terminal screw M4 M4 M5 M5Max. tightening torque Nm 1.6 1.6 4 4
Notes Main switch characteristics to IEC/EN 60 204; positive opening of contacts, operator element positively located on shaft
1) P1-...:Max. 2 cross-section sizes difference admissible when using 2 conductorsP3-...:Max. 1 cross-section size difference admissible when using 2 conductors
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/093Moeller HPL0211-2001/2002
P Switch-DisconnectorsTechnical Data
P1-25 P1-32 P3-63 P3-100
Switching capacityAC
Rated making capacity cos
v = 0.35 A 240 320 800 950Rated breaking capacity 230 V AC, cos
v = 0.35 A 190 260 640 760Motor load switches 400 V AC, cos
v = 0.35 A 150 300 600 740500 V AC, cos
v = 0.35 A 170 290 590 880690 V AC, cos
v = 0.35 A 150 250 340 520AC-21A Load-break switches Rated operational current
Ie380 – 440 V, 3
hA 25 32 63 100
AC-3 Motor load switches,for operationalswitching
220 – 240 V, 3
h kW 5.5 7.5 15 22380 – 440 V, 3
h kW 7.5 13 30 37500 V, 3
h kW 7.5 18.5 30 45660/690 V, 3
h kW 7.5 15 30 37AC-23A Motor load switches
(main switches,maintenance switches)
220 – 240 V, 3
h kW 7 8.5 18.5 30380 – 440 V, 3
h kW 13 15 37 50500 V, 3
h kW 11 18.5 37 65660/690 V, 3
h kW 11 18.5 30 75DC
DC-1 Load-break switchesL/R = 1 ms
Rated operational current
Ie A 25 32 63 100
Voltage per contact pair in series
V 60 60 60 60
DC-23A Motor load switchesL/R = 15 ms
Figures in brackets:number of contacts to be switched in series
24 V A 25 (1) 25 (1) 50 (1) 50 (1)48 V A 25 (2) 25 (2) 50 (2) 50 (2)60 V A 25 (3) 25 (3) 50 (3) 50 (3)120 V A 12 (3) 12 (3) 25 (3) 25 (3)
N-P1... N-P3...
Switched neutralSwitching capacity As P1-32 As P3-100
HI11-P1/P3
Auxiliary contacts
Standards Control circuit isolator to IEC/EN 60 947-5
Rated insulation voltage
Ui V AC 500Rated uninterrupted current
Iu with max. cable connected A 10Rated operational current
Ie AC-15 220 – 240/380 – 415/500 V A 6/4/3DC-13 250 V DC A 0.55
125 V DC A 1.1Short-circuit rating without welding,Max. fuse A gG/gL 10Terminal capacity Min. solid or flexible mm2 0.75/0.5
Max. solid or flexible mm2 2.5/1.5Max. tightening torque Nm 0.6Control circuit reliability at24 V DC, 10 mA
Fault probability HF < 10−5, < 1 fault in 100 000 operations
Moeller HPL0211-2001/2002
T Rotary Switches, P Switch-DisconnectorsTripping Characteristics
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/094
Component lifespan in relation to breaking current and utilization category 1)
In order to achieve a reasonable lifespan in utilization category AC-4 (severe duty: 100 % inching, reversing or plugging), the stalled motor current should not exceedthe rated current of the switch at AC-21.
Notes 1) AC-3 and AC-21 at 400 V, AC-15 at 230 V
1 2 3 4 5 6 7 8 10 20 A
T0
0.5
1
2
3
4568
10
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
Breaking pointAs control switch (AC-15)As motor load switch (AC-3)As load-break switch (AC-21)
Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)
T3
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
1 2 3 4 6 128 30 40 A0.5
1
2
3456
8
10
16 20 25
0.6
0.8
Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)
T5B, T5
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
1 2 3 4 6 128 30 400.5
1
2
3456
8
10
16 20
0.6
0.8
60 80 100 A
T5B
T5B T5
T5
T5B T5
T5B T5
Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)
T6, T8
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
4 6 8 16120.1
0.2
0.3
0.5
1
2
3
5
6020 30 40 100 250A
T6 T8
T6 T8
T6
T8
T6
T8
Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)
P1
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
1 2 3 4 6 128 30 40 A0.5
1
2
3456
8
10
16 20 25
0.6
0.8
P1-32
P1-25
P1-25 P1-32
P1-25
Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)
P3
Com
pone
nt li
fesp
an (o
pera
tions
10
)
5
1 2 3 5 2010 80 100 A0.1
40 60
0.2
0.3
0.40.50.6
0.81
2
P3-100P3-63
P3-63 P3-100
P3-100
P3-63
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/095Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesTechnical Data
General technical dataStandards IEC/EN 60 947, UL, CSA
Control switches to IEC/EN 60 947-5-1Control circuit isolators to IEC/EN 60 947-5-1
Control circuit isolators (IEC/EN 60 947-5-1) Maximum 6 contacts; switching angle 90°
Lifespan, mechanical Operations Ops. > 1
x 106
Max. operating frequency Ops./h 3000Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50
Enclosed Min./Max. °C −25/+40Mounting position As requiredMechanical shock resistance (shock duration 20 ms) g > 15Protection against direct contact Finger and back-of-hand proof to IEC 536
Terminal capacity Solid 1 conductor Min./Max. mm2 0.75/1.52 conductors Max. mm2 1.5 (AWG 14)
Flexible 1 conductor Min. mm2 0.75 (AWG 18)2 conductors Max. mm2 0.75
Terminal screw M2.5Max. tightening torque Nm 0.35Dimensions
a Page 07/108
ContactsMechanical values
Contacts Max. 16Contact units Max. 8Switching angles 90°/60°/45°/30°Min. switching angle for On-Off-On 60°Switch positions Max. 12Thickness of gold coating
mm 35Electrical values
Rated operational voltage
Ue V AC 500Rated impulse withstand voltage
Uimpapplicable to systems with earthed neutral point kV 4 Overvoltage category/pollution degree III/3Rated insulation voltage
Ui V AC 500 (UL/CSA 300 V AC)Rated uninterrupted current
Iu with max. cable connected A 10Switching capacity
AC-23AMotor load switches
220 – 240 V, 3
h kW 1.8380 – 440 V, 3
h kW 3500 V, 3
h kW 3.7220 – 240 V, 1
h kW 0.75380 – 440 V, 1
h kW 1.1AC-15Control switches
220 – 240 V, 1
h A 2.5380 – 415 V, 1
h A 1.5440 V, 1
h A 1DC-1Load-break switches
1 – 24 V DC A 10110 – 240 V DC A 0.7 – 0.3
DC-13Control switches
L/R = 50 msMax. 32 V DC per contact
A 3
Switching capacity for North America240 V, 3
h HP 1277 V, 1
h HP
o
300 V AC A 10 Heavy dutyShort-circuit protective device
Maximum fuse A gG/gL 10Control circuit reliability
24 V DC, 10 mA Fault probability
HF < 10−5, < 1 fault in 100 000 operations
Moeller HPL0211-2001/2002
T0, T3 Rotary Switches Dimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/096
Flush mounting
T0.../E (+ H3-T0)T3.../E (+ H3-T0)
Drilling dimensions
Centre mounting
T0.../EZ (/OFS)T3.../EZ (/OFS) T0 T3 Drilling dimensions
T.../EZ/OFS
48
48
ZFS-...-T0
17
525 101
c20 35
H3-T0
75
90
10 –
11
3.1 – 3.5
12.2
30
48
4817
1.5 – 5
c21 35
45
48
48 54
61
3.2
24.1
+0.
4 0
22.3 +0.4 0
35
29
Type c20 c21T0-1...T0-2...T0-3...T0-4...T0-5...T0-6...T0-7...T0-8...T0-9...T0-10...T0-11...
41506069798898107117126136
6170808999108118127137146156
Depth of one contact unit: 9.5 mm
Type c20 c21T3-1...T3-2...T3-3...T3-4...T3-5...T3-6...T3-7...T3-8...T3-9...T3-10...T3-11...
4456677990102113125136148159
64768799110122133145156168179
Depth of one contact unit: 11.5 mm
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/097Moeller HPL0211-2001/2002
T0, T3 Rotary Switches Dimensions
Service distribution board mounting
T0.../IVS Drilling dimensionsBase
T3.../XZ + IVS-T0 Drilling dimensionsBase
Rear mounting
T0.../ZT3.../Z
Drilling dimensions Base
Drilling dimensionsDoor
� Can be extendedusing ZVV-T0,
F 4
x 25 = 100 mm
54
5545 M4 50
48
60 50
� 5
� 528
45
55c22
5
63
6545
54
M4 65
5
� 5
48
75 65
63
28
45
55c22
5 �
548
4817
ZFS-...-T0
M450
5 – 5.5
36
36
5 – 5.5
3636M465
48
50 60
63
65 7555
5 5
25
c23c24 35
O 5
O
O
O
5
5
38,ZAV:
54154
22.3 + 0.4 0
22.3 + 0.4 0
100R
a
T3
T0
Type c20 c21 c22 c23 c24f/F
c24 with
F 4 ZAVc25
T0-1...T0-2...T0-3...T0-4...T0-5...T0-6...T0-7...T0-8...T0-9...T0-10...T0-11...
41506069798898107117126136
6170808999108118127137146156
778796106115125134144154163173
485767768695105114124133143
86 – 10296 – 112105 – 121115 – 131124 – 140134 – 150143 – 159153 – 169162 – 178172 – 188181 – 197
202212221231240250259269278288297
72729191–––––––
Depth of one contact unit: 9.5 mm
Type c20 c21 c22 c23 c24f/F
c24 with
F 4 ZAVc25
T3-1...T3-2...T3-3...T3-4...T3-5...T3-6...T3-7...T3-8...T3-9...T3-10...T3-11...
4456677990102113125136148159
64768799110122133145156168179
8092103115126138149161172184195
5163748697109120132143155166
86 – 105101 – 115112 – 128124 – 139135 – 151147 – 162158 – 174170 – 185181 – 196193 – 208204 – 219
205216228239251262274285296308319
7979101101–––––––
Depth of one contact unit: 11.5 mm
Moeller HPL0211-2001/2002
T0, T3 Rotary Switches Dimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/098
Flush mounting main switches
T0.../EA/SVBT3.../EA/SVB
Drilling dimensionsDoor
T0
T3
Rear mounting main switches
T0.../V/SVBT3.../V/SVB
Drilling dimensions Base
Drilling dimensionsDoor
� Interlock can be extended using ZVV-T0 + ZAV-T0,
F 4
x 25 = 100 mm
T0
T3
Sheet steel enclosures
T0-.../ST, P1-.../ST P3-.../ST
T3-.../ST, T5(B)-.../ST
65
3317
48
ON
OFF
OFF
I
o
o
25 c2035
5ZFS-...T0
61
54
49
45
3.1 – 3.5
30
10 –
11
12.2
I
o
o
65
3317
48ZFS-...T0
55 25
c23c24 35
38, 54 ZVV+ZAV: 154
100R
ON
OFF
OFF
� 65 7563
5
5
M465
M450
�
�
50 60
49
� 522.3 + 0.4 0
5 – 5.5
36
36
M20
M4
174
M20162
60
104
130
M4
184
M20
M25
M25
M20
184
140
184
140
M4
284
M25
M32
M25
184 193
140
140
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/099Moeller HPL0211-2001/2002
T0, T3 Rotary Switches Dimensions
Surface mounting
T0.../I1 Drilling dimensionsBase
T3.../I2 Drilling dimensionsBase
Surface mounting main switches
T0.../I1/SVBDrilling dimensionsBase
T3.../I2/SVB Drilling dimensionsBase
F 3 padlocks
L-...
80
120
33.5
c25 27
137 M20
127
M4
L-...
100
160
35.5
c25 c33
180 M25
∅8
171
M4
L-...
80
120
33.5
c25 35
M20
137
I
OFFo
ON
oOFF 12
7
M4
L-...
100
160
33.5
180
35c25
M25
�8
I
OFFo
ON
oOFF
d b
d = 4 – 8 mmb + d F 47 mm
171
M4
Type c25T0-1...T0-2...T0-3...T0-4...
75759595
Type c25 c33T3-1...T3-2...T3-3...T3-4...T3-5...
8080100100145
2727353535
Moeller HPL0211-2001/2002
T0, T3 Rotary Switches, AccessoriesDimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/100
Key operation
S-T0S-SOND...-T0
T0.../E(I1) + S-(SOND-)T0T3.../E(I2) + S-(SOND-)T0
T0.../Z + S-(SOND-)T0T3.../Z + S-(SOND-)T0
T0.../EZ � T0../E + EZ-T0 + S-(SOND-)T0T3.../EZ � T3../E + EZ-T0 + S-(SOND-)T0
Cylinder lock
SVA-T3 T0.../I1/SVAT3.../I2/SVA
T0.../E/SVA...T3.../E/SVA...
T0.../Z/SVA...T3.../Z/SVA...
Push-button interlockPadlocking feature Dimensions as DTV-T3
DTV-T3SVC-T3
T0.../I1/DTVT3.../I2/DTVT0.../I1/SVCT3.../I2/SVC
T0.../E/DTV...T3.../E/DTV...T0.../E/SVC...T3.../E/SVC...
T0.../Z/DTV...T3.../Z/DTV...T0.../Z/SVC...T3.../Z/SVC...
Mounting clearance
� Mounting clearances a and b: 4 mm� Exposed conductive part (metal)
17
27
48
48
ZFS-...-T0
1930
5
36
12.2
3.1 – 3.5
30
10...
11
527
44
5 – 5.5
36
36
22.3 + 0.4 0
100R
2 – 5
c20 22:25 – 28 30:23 – 26
3.2
30.5
17
3.2 12.5
��
22.3 + 0.4 0
73
48
ZFS...-T0 56
73
46 30
5673
46 30
56
73
46 30
73
48
ZFS...-T0 56
73
46
48
56
73
46
48
56
73
46
48
b
a
a
b
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/101Moeller HPL0211-2001/2002
T5B, T5 Rotary SwitchesDimensions
Flush mounting
T5(B).../E Drilling dimensionsDoor
Rear mounting
T5(B).../Z Drilling dimensionsBase
Drilling dimensionsDoor
� Shaft can be extended using ZAV-P3,
F 4
x 25 = 100 mmFlush mounting main switches
T5(B).../EA/SVBDrilling dimensionsDoor
Rear mounting main switches
T5(B).../V/SVB Drilling dimensionsBase
Drilling dimensionsDoor
� Can be extendedusing ZVV-P3,
F 4
x 25 = 100 mm
88
8827
ON
OFF
I
o
18
c2
86
37
514
37
4.1 – 4.5
12 – 13
ON
OFFo
I
88
8827
48
5 – 5.5
48
30.5
c20
c2 37
2525
5
38, 54 ZAV: 154
7973 86
� 6.4
100R
a
88
2788
ON
OFF
OFF
I
o
o
5
25c2
88
80/9
0
40.516.5
44
100
80/9
0
14
37
4.1 – 4.5
12 – 13
ON
OFF
OFF
o
I
o
48
5 – 5.5
48
30.5 48
5 – 5.5
48
30.5
2788
88
1216.5
5c20
5
25 25
40.5
44
100
80/9
0
73
85
100R�
Moeller HPL0211-2001/2002
T5B, T5 Rotary SwitchesDimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/102
Surface mounting
T5(B).../I4 T5.../I5
Surface mounting main switches
T5(B).../I4/SVB Drilling dimensions
F 3 padlocks
T5.../I5/SVB Drilling dimensions
External fixing bracket
160 c22 37
M20
M25M32
240
33.5 33
.5
280
L-...
200 c22 37
L-...
M20
M25M50
L-...
160
240
33.5
c22 44
193
142
M5
I
OFFo
ON
oOFF
d b
d = 4 – 8 mmb + d F 47 mm
280
33.5
L-...
200 c22 44
233
182
M5
I
OFFo
ON
oOFF
Type c2 c20f/F
c24 with
F 4 ZAVc21 c22
T5(B)-1...T5(B)-2...T5(B)-3...T5(B)-4...
547187104
92 – 107109 – 124125 – 140142 – 157
207224240257
9090123123
125 (95)125 (95)160 (160)160 (160)
T5(B)-5...T5(B)-6...T5(B)-7...T5(B)-8...T5(B)-9...T5(B)-10...
120137153170186203
158 – 173175 – 190191 – 206208 – 223224 – 239240 – 356
273290306323339356
––––––
––––––
Depth of one contact unit: 16.5 mm
The rotary switches T5B and T5 are of identical designbut differ in their contacts
20 5.5 6.2
7.5
5
2.5
M5
∅6
50
34
4.6
7.8
6
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/103Moeller HPL0211-2001/2002
T6, T8 Rotary SwitchesDimensions
Flush mounting
T6.../ET8.../E
Flush mounting main switches
T6-2/EA/SVB
Rear mounting main switches
T6-2/V/SVB
F 3 padlocks for T.../SVB
T6-160-6/V/SVB-SW/HI11 T8-3-8342/V/SVB-SW/HI11
Drilling dimensionsDoor
T6: 4 M5
x 20T8: 4 M6
x 20
15058
5c2 c30
b2
a2
88
88
90
125
ZS
5.4
68
68 88
88 5
100 50
88
88
90
125
ZS
5.4
68
68 88
884.5 5
110 50
40100 300
R
d b
d = 4 – 8 mmb + d F 47 mm
9
88
73
5.5 1
93 216 200
5
76224
6.4 H-T6-100
118
22
68108
100R
7
130
250
1044.5
172.8
315 218
9.2
86.5
7 1
130
68H-T8
19
100R
Type a2 b2 c2 2 BE 3 BE c30 d1 d2 x1 y1BE = Number of contact units
T6...T8.../ET8.../SVB
88130–
88130–
100––
152173–
4462–
∅ 26–30∅ 22–25∅ 38–42
∅ 6.0∅ 7.0∅ 7.0
6810468
6810468
d2
d1
x1
y1
Moeller HPL0211-2001/2002
P Switch-DisconnectorsDimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/104
Flush mountingP.../E
Centre mounting
P1.../EZ Drilling dimensionsDoorP1-.../E P1-.../EZ P3-.../E
Service distribution board mounting
P3.../IVS
F 3 padlocks
P1.../IVS
Rear mounting
P.../Z
� Shaft can be extended using ZAV-...,
F 4
x 25 = 100 mm
Drilling dimensionsBaseP1.../Z
P3.../Z
Drilling dimensionsDoor
ON
0
I
OFF
a2
b2b2
2
b3
a3
L3 L1
T3 T1
L2
T2
1
2
3
4
5
6
5c2 c21
P1.../EZ = c2 + 5 mm
4.1 – 4.53.2
22.3 +0.40
12.5
10 –
11
12.2
3.1 – 3.5
30
14
37
12 – 13
b3
a4
c22c23
c3
5
45
N
HI11
L3L2L1
T3T2T1
L3L2L1
T3T2T1
a32 a32
a31
d b
d = 4 – 8 mmb + d F 47 mm
49
L1 L2 L3
T1 T2 T3
55
28
b3 45
5 c3
�
38154
3
5
a3
5
b22
b2
a2
c21c25c20
R 100
c31 c32b3
5 – 5.5
M4 65 36
36
22.3 +0.40
M4 75
25
5 – 5.5
48
48
30.5
Type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31P1P3
4887
4972
53.571.5
6587
4887
87125
1518
1515
83114
4887
7083
6587
1727
125175
32–
4960
Type c2 c3 c20f/
F
c20 with
F4ZAV/ZVV
c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
P1P3
5959
8682
96 – 112103 – 118
212218
3537
3241
6563
6881
5865
3544
7790
2525
2525
2729
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/105Moeller HPL0211-2001/2002
P Switch-DisconnectorsDimensions
Flush mounting main switches
P.../EA/SVB Drilling dimensionsDoor
P1... P3...
Rear mounting main switches
P.../V/SVB
� Interlock can be extended using ZVV-T0 + ZAV-T0,
F 4
x 25 = 100 mm
Drilling dimensionsBase
P1.../V/SVB
P3.../V/SVB
Drilling dimensionsDoor
Surface mounting
P1.../I2
Surface mounting main switches / safety switchesP1.../I2/SVBP1.../I2/SI
Drilling dimensions
5
b3
a3
ON
OFF
b22
ZFS-....
c27c225
o
o OFF
I 1
2
3
4
5
6
N
N y
y
a22
b21
a21
b31
H-P...
14
4.1 – 4.5
10 –
11
12.2
3.1 – 3.5
30 37
12 – 13
5
38 154
3
R 100
I ON
OFF
OFF
ZFS-.... 5
b3
c 27
o
o
1
2
3
4
5
6
N
N
a 22
b22
b31
b21
a 21 a 3 c 25
c 20
H-P... �5 – 5.5
M4 65 36
36
22.3 +0.40
M4 75
25
5 – 5.5
4848
30.5
L-...
a23
160
b24
c28 c33
M25
171
c27
M4
b23
M25M258
Moeller HPL0211-2001/2002
P Switch-DisconnectorsDimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/106
Surface mountingP3-63/I4
Surface mounting main switches/safety switchesP3-63/I4/SVBP3-63/I4/SIT5B-.../I4/SI
Drilling dimensions
Surface mounting
P3-100/I5
Surface mounting main switches/safety switchesP3-100/I5/SVBP3-100/I5/SIT5-.../I5/SI
Drilling dimensions
L-...
a23
L—PKZ0
95 37
b23
b24
95 44
193
142
M5
M25M32 M20
L-...
a23 125 37 125 44
233
182
M5
L—PKZ0
M25M50 M20
b23
b24
Type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31P1.../I2P3-63/I4P3-100/I5
488787
497272
53.571.571.5
658787
488787
100160200
151818
151515
83114114
488787
708383
658787
172727
180240280
35.535.535.5
496060
Type c2 c3 c20f/
F
c20 with
F4ZAV/ZVV
c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
P1...P3-63P3-100
595959
868282
96 – 112103 – 118103 – 118
212218218
353737
324141
656363
688181
586565
354444
80125125
252525
252525
273737
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/107Moeller HPL0211-2001/2002
P Switch-Disconnectors, AccessoriesDimensions
Cylinder lock
SVA-T3 P1.../I2/SVA P1.../E/SVA P1.../Z/SVA
Padlocking feature
SVC-T3 P1.../I2/SVC P1.../E/SVC P1.../Z/SVC
ModulesSwitched neutral N-P...HI 11-P1/P3 auxiliary contacts
F 3 padlocks
73
48
ZFS...-T0 56
73
46 30
56
73
46 30
56
73
46 30
73
48
ZFS...-T0 5673
46
48
56
73
46
48
56
73
46
48
L3 L2 L1
T3 T2 T16 4 2
5 3 1 b31
a3
N-P
H-P...
HI 11
N
N
1 3
2 4 6
a32 a31 a32 a32 a31 a32
a33
5
Type a3 a31 a32 a33 b31P1-...P3-..
4972
1518
1515
83114
4960
d b
d = 4 – 8 mmb + d F 47 mm
Moeller HPL0211-2001/2002
TM Mini Rotary SwitchesDimensions
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/108
Flush mounting
TM.../E Drilling dimensions
Control circuit isolatorsLockable using 2 padlocks ∅ 4 mm or 1 padlock ∅ 6 mm
TM-.../E/SVB(-SW) Drilling dimensions
Centre mounting
TM-.../EZ Drilling dimensions1)
Centre mounting with key operation
TM-...+EZ/S-.. Drilling dimensions1)
Service distribution board mounting
TM-.../IVS
Notes 1)) Drilling dimension options: 16.2 mm = use without adapter � RMQ16; 22.3 mm = adapter required � RMQ-Titan
28
c20
3
� 4
.8
30
30
28
28
M3 M33.2
20
8
48
48
28
c21
3
35
38
38
M4 M4
104.2
30
F 5.5
2830
17/19
1.7
17.9
3.2
24.1
+0.
4 0
22.3 +0.4 0
16.2 +0.2 0
30
30
5.5
28
c20 3512
17/19
1.7
17.9
3.2
24.1
+0.
4 0
22.3 +0.4 0
16.2 +0.2 0
Type c20 c21TM-1...TM-2...TM-3...TM-4...TM-5...TM-6...TM-7...TM-8...
395163758799111123
425466
Depth of one contact unit: 12 mm
S H35
60
45
AUTOHAND
O Type S HTM-1...TM-2...
4446
2126.5
Depth of one contact unit: 12 mm
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/109Moeller HPL0211-2001/2002
P..., T5..., P7 Safety SwitchesEngineering Notes
Maintenance and safety switches have the same electrical function. They are designed to isolate electrical installations (loads) safely from the mains while maintenance work or repairs are being carried out, thereby ensuring that no hazard arises to personnel, machinery or product.The safety switch is an additional, enclosed main switch = isolator for an individual electrical load, and can be fitted directly next to the motor or the electrical load, ensuring that work on them can be carried out safely provided the 5 safety rules to VDE 0105 are observed. This is of special importance if there is any possibility whatsoever of the main switch being wrongly identified.
ApplicationBy securing the switch in the Off position with his own padlock (up to three can be fitted), the fitter/electrician can protect himself against the possibility of any other person switching On the machine without authority.
Maintenance switches are merely additional, enclosed main switches with a padlocking facility. Such switches can be found on Pages 07/012–015 or07/024–025 of this catalogue.
FeaturesSafety switches are housed in insulated enclosures as standard and bear the inscription “Safety switch” on a bright orange label. Labels in other languages are available.Switches to be used for Emergency-Stop switching have a special red handle and a yellow locking collar in accordance with STOP category 0 toIEC/EN 60204.If the switch is not admissible for use as an Emergency-Stop switch, both parts are grey for P7 switch-disconnectors (Type suffix “-GR”) or black for T and P switches (Type suffix “-SW”).The cover and handle are interlocked when a padlock is in place.
SelectionSwitches must be selected according to the following criteria:1) The motor switching capacity, where the switch is
fitted in such a way that the operator may use it for operational On and Off switching.
2) The motor rating applies for 3 poles as standard. Where the motor rating is divided between 6 poles, such as for a motor with star-delta starting, the 1.73 fold rating can be controlled with a 6-pole switch.
3) The uninterrupted current, where the switch has a load-shedding contact (LA). The load-shedding contact is an auxiliary contact, which is closed in the On position and opens early when switching Off, so that a contactor in the circuit takes over the switching capacity, and the maintenance/safety switch operates at zero load. When switching On, the LA closes later than or at the same time as the main contacts. With T and P switches, this is achieved by the auxiliary make contact, with P7... switches, it is achieved by series connection of the early-make auxiliary contact (VHI) and a standard auxiliary contact (NHI).
4) The uninterrupted current, provided that the switch is safely prevented from switching under load.
5) This can be achieved for example by padlocking the handle (which may need to be changed accordingly) in the On position.This is not admissible for switches with a red/yellow handle.
Old Type/New TypeOld Type New TypeP3-63/I-SI(-SW)(+HI..) P3-63/I4-SI(-SW)(+HI..)P3-63/I-SI(-SW)+N-P3 P3-63/I4-SI(-SW)+N-P3P3-63/I-SI(-SW)+N+HI11
P3-63/I4-SI(-SW)+N+HI11
T5B-3-8342/I-SI(-SW) T5B-3-8342/I4-SI(-SW)T5B-4-.../I-SI(-SW) T5B-4-.../I4-SI(-SW)P3-63/I-SI(-SW)(+HI..) P3-63/I4-SI(-SW)(+HI..)P3-63/I-SI(-SW)+N-P3 P3-63/I4-SI(-SW)+N-P3T5-.../CI19/SIH T5-.../I5-SIT5-3-8342/CI19/SIH T5-3-8342/I5-SIT5-.../CI19/SIH T5-.../I5-SI
Technical datafor P switch-disconnectors a Page 07/092Technical datafor T5(B) switch-disconnectors
a Page 07/090Dimensions for P
a Page 07/104Dimensions for T5(B)
a Page 07/101P7 Safety Switches63 A – 250 A
a Page 10/016
Safety switch with load shedding and indication
Indication Load sheddingOn Off
K1M
L2
NL3
L1
F1
K1M2
1
4
3
6
5
F2
1 3 5
2 4 6
M3
7 9 11
8 10 12
Q1
U V W
A2K1M
A1
A2H1 H2
F0 FAZ-B4HI
95
96
21
22
F2
O
13
14
I13
14
Moeller HPL0211-2001/2002
T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/110
Design notes for non-standard contact sequences
Key to type references
T . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ./ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+ . . . . . . . . . . . . . . . . . .
� � � � �
Switch size Number of contact units(2 contacts per contact unit)
Contact sequence numberWith manufacturing country identifier.For initial order enclose completed form (see next Page).Contact sequence number is issued by factory.For subsequent orders, Type suffix is sufficient.
Mounting form• Mounting form /E• Centre mounting /EZ (for T0, T3)• Surface mounting /I...1)
• Service distribution board mounting /IVS (for T0)
• Rear mounting /Z• Flush mounting main switches .../EA/
SVB2)
• Surface mounting main switches /I.../SVB
• Rear mounting main switches/V/SVB2)
• Mounting forms for TM: /E, /EZ or /IVS
Accessories
a Page 07/056 – 071State in full with every order!For TM.../EZonly +EZ/S... is possible
a Page 07/083
Max.units
Max.contacts
T0 11 22T3 11 22T5B 10 20T5 10 20TM 8 16
Contact sequenceThe Form FO 2 (see next Page) makes it easy to determine the contact sequence. Master copy
a Page 07/112
Switching angles30, 45, 60, 90°Preferred angle: 60°For On/Off switches: 90°For main switches: 90° as FS 908 Page
a 07/054Interruption of contact between 2 switch positions (On-Off-On) not admissible on T0;or on T3 and TM at switching angles of 30°, 45°; or on T5(T5B) at a switching angle of 30°
Terminal markingsTM switches have consecutive terminal markings, beginning with 1.
Spring-returnThe switching movement is limited by a stop. The switch returns under spring pressure to the last indexed position. Where a switch has spring-return from both directions, a maximum of three positions can be traversed.The return angle is <
m switching angle. A maximum of 6 contacts can be returned at the same time.
Fleeting contactsDuration of contact depends primarily on the speed of actuation. If a contactor is to be actuated by means of fleeting contact, the switching angle of the rotary switch must not be less than 60°, or the switching pulse may be too short. Fleeting contacts always act in both directions.
Complete rotationPossible only with a total switching angle of 360°. Unrestricted rotation in either direction. The number of switch positions multiplied by the switching angle must equal 360°. TM with 12 positions every 30° is possible only with complete rotation, not with stop.
Number of contact unitsNumber of contacts = Round up to nearest whole
2
Each contact chamber = contact unit has 1 or 2 contacts, each operated by a cam.On T5(B) one cam operates both contacts. Consequently:Where the total switching angle is less than 180°, the contacts can be operated independently of one another. At switching angles of 180° and above, two contacts per chamber are possible only if their switching sequences are the same, but offset by 180° (e.g. T5B-4-8235 step switch).
Standard featuresAs for rotary switches with standard contact sequences
a Page 07/006, 072 Notes PageTechnical data 07/090Dimensions 07/096Available mounting formsT0 07/084T3 07/085T5B 07/086T5 07/087TM 07/088
NotesThe sequence of the contacts may be changed if technical reasons so dictate.For non-standard switches it is preferable to arrange the links so that terminals whose numbers differ by 4 are linked with one another, e.g. terminals 1-5-9; 2-6-10; 3-7-11- or 4-8-12-. Such links can be removed (also applies for standard switches), whereas links 1-3, 2-4, 5-7, 6-8 cannot abe removed because they are situated within the switch.
Links between an even number and an odd number (e.g. 2-3) cannot be provided ex-factory, and must be supplied by the user.
1) T0-.../I1 up to 4 contact units T3-.../I2 up to 5 contact units
2) T0 up to 8 contacts = 4 contact units, T3 up to 12 contacts = 6 contact units
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/111Moeller HPL0211-2001/2002
T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences
Erstbestellung für Nockenschalter T KombinationenInitial order for a T rotary switch combinationPremière commande de combinaisons de Commutateur T à cames
Auftrags-Nr.:Order number:N° de commande :
Position:Item:Poste :
Büro:Office:Bureau :
Bearbeiter:Name:Employé :
Kunde:Customer:Client:
Kundenspez.-Nr.:Customer number:N° client :
Datum:Date:Date :
Hinweis:Note:Note :
Die Anzahl der möglichen Kontakte sowie die Kombinationsmög-lichkeiten mit den Baufor-men entnehmen Sie bitte dem Hauptkatalog.
The number of possible contacts as well as possible combinations with mounting forms are shown in the Main Catalogue.
Reportez-vous au Catalogue Général pour connaître le nombre maximal de contacts et les possibilités de combinai-son selon les modèles.
Stückzahl:Quantity:Quantité :
Schaltwinkel:Switching angle:Angle de rotation :
Type:Type:Réfèrence :
Anzahl Kontakte:No. of contacts:Nombre de contacts :
Bauform:Mounting form:Modèle :
q 30
q TM
q 1
q 12
q✗ E
q✗ 45
q✗ T0
q 2
q 13
q EA/SVB
q EA/SVB-SWDM/Stück:DM/each:Prix unitaire :
q 60
q T3
q 3
q 14
q EZ
q EZ/OFS
q 90
q T5B
q 4
q 15
q I...
q T5
q 5
q 16
q I.../SVB
q I.../SVB-SW
q 6
q 17
q IVS
q 7
q 18
q V/SVB
q V/SVB-SW
q 8
q 19
q X
q XZ
q✗ 9
q 20
q Z
q 10
q 21
q✗ + S-T0
q 11
q 22
q +___________________
Frontschild Nr.Front Plate No.Plastron N°
FS _______________
Baueinheiten/Contact units/Galettes1 2 3 4 5 6 7 8 9 10 11
Rundschaltung
k Complete rotationRotation totaleautom. Rückzug
k✗ Spring-returnRetour autom.
BeschriftungMarking/Repérage
GradDegrees/Degrés
12
34
56
78
910
1112
1314
1516
1718
1920
2122
2324
2526
2728
2930
3132
3334
3536
3738
3940
4142
4344
270 1 ✗ ✗ ✗ ✗ ✗ ✗ ✗300315 2 ✗ ✗ ✗ ✗330 ✗
0 3 ✗ ✗ ✗3045 4 ✗60
Cont
act c
lose
d on
ly in
po
sitio
n 1
Switc
hing
with
inte
rrup
tion
of c
onta
ctSw
itchi
ng w
ithou
t int
erru
p-tio
nCo
ntac
t clo
sed
in
posit
ions
1 +
3Co
ntac
t clo
sed
inpo
sitio
ns 1
to 3
Flee
ting
cont
act
(onl
y w
ith 6
0° o
r 90°
)La
te-b
reak
con
tact
Early
-mak
e co
ntac
t
Cont
act w
ith a
utom
atic
sprin
g-re
turn
90120135150 Key withdrawability with ..S-T0 or SVA-T3:180 Pos. 1: Key withdrawable � With SVA-T3, it is possible to switch
between Pos. 1 and 2 even after the key has been withdrawn.210 Pos. 2: Key withdrawable
225 Pos. 3: Key withdrawable240 Pos. 4: Key not withdrawable:
Schlüssel abziehbarKey withdrawableRetrait de la clé
x
Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l’usine) T___________________________________
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 19
18
21
20
23
22
25
24
27
26
29
28
31
30
33
32
35
34
37
36
39
38
41
40
43
42 44 3300
30300
270
240 225
210180
150
135 120
90
60315 45
Es is
t mög
lich,
das
s si
ch a
us te
chni
sche
n G
ründ
en d
ie R
eihe
nfol
ge d
er K
onta
kte
ände
rt.
The
sequ
ence
of c
onta
cts
may
be
chan
ged
for t
echn
ical
reas
ons.
L’or
dre
des
cont
acts
peu
t êtr
e m
odifi
é po
ur d
es ra
ison
s te
chni
ques
.
Max. characters per switching angle on FS plateDegrees TM-E TM-EZ TM-IVS T0(3) T5(B)0.180 5 5 6 13 1330, 210, 330 8 7 4 8 845, 135, 225, 315 6 5 4 6 760, 120, 240, 300 5 5 3 5 790, 270 5 4 1 4 7150 4 4 4 8 8
Moeller HPL0211-2001/2002
T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences
Rota
ry S
witc
hes
Swit
ch-D
isco
nnec
tors
07/112
Erstbestellung für Nockenschalter T KombinationenInitial order for a T rotary switch combinationPremière commande de combinaisons de Commutateur T à cames
Auftrags-Nr.:Order number:N° de commande :
Position:Item:Poste :
Büro:Office:Bureau :
Bearbeiter:Name:Employé :
Kunde:Customer:Client:
Kundenspez.-Nr.:Customer number:N° client :
Datum:Date:Date :
Hinweis:Note:Note :
Die Anzahl der möglichen Kontakte sowie die Kombinationsmög-lichkeiten mit den Baufor-men entnehmen Sie bitte dem Hauptkatalog.
The number of possible contacts as well as possible combinations with mounting forms are shown in the Main Catalogue.
Reportez-vous au Catalogue Général pour connaître le nombre maximal de contacts et les possibilités de combinai-son selon les modèles.
Stückzahl:Quantity:Quantité :
Schaltwinkel:Switching angle:Angle de rotation :
Type:Type:Réfèrence :
Anzahl Kontakte:No. of contacts:Nombre de contacts :
Bauform:Mounting form:Modèle :
q 30
q TM
q 1
q 12
q E
q 45
q T0
q 2
q 13
q EA/SVB
q EA/SVB-SWDM/Stück:DM/each:Prix unitaire :
q 60
q T3
q 3
q 14
q EZ
q EZ/OFS
q 90
q T5B
q 4
q 15
q I...
q T5
q 5
q 16
q I.../SVB
q I.../SVB-SW
q 6
q 17
q IVS
q 7
q 18
q V/SVB
q V/SVB-SW
q 8
q 19
q X
q XZ
q 9
q 20
q Z
q 10
q 21
q +____________________
q 11
q 22
q +____________________
Frontschild Nr.Front Plate No.Plastron N°
FS _______________
Baueinheiten/Contact units/Galettes1 2 3 4 5 6 7 8 9 10 11
Rundschaltung
k Complete rotationRotation totaleautom. Rückzug
k Spring-returnRetour autom.
BeschriftungMarking/Repérage
GradDegrees/Degrés
12
34
56
78
910
1112
1314
1516
1718
1920
2122
2324
2526
2728
2930
3132
3334
3536
3738
3940
4142
4344
270300315330
030456090
120135150180210225240
Schlüssel abziehbarKey withdrawableRetrait de la clé
x
Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l’usine) T__________________________
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 19
18
21
20
23
22
25
24
27
26
29
28
31
30
33
32
35
34
37
36
39
38
41
40
43
42 44 330
030
300
270
240 225
210180
150
135 120
90
60315 45
Es is
t mög
lich,
das
s si
ch a
us te
chni
sche
n G
ründ
en d
ie R
eihe
nfol
ge d
er K
onta
kte
ände
rt. T
he s
eque
nce
of c
onta
cts
may
be
chan
ged
for t
echn
ical
reas
ons.
L’o
rdre
des
con
tact
s pe
ut ê
tre
mod
ifié
pour
des
rais
ons
tech
niqu
es.
Max. characters per switching angle on FS plateDegrees TM-E TM-EZ TM-IVS T0(3) T5(B)0.180 5 5 6 13 1330, 210, 330 8 7 4 8 845, 135, 225, 315 6 5 4 6 760, 120, 240, 300 5 5 3 5 790, 270 5 4 1 4 7150 4 4 4 8 8
Rota
ry S
wit
ches
Swit
ch-D
isco
nnec
tors
07/113Moeller HPL0211-2001/2002
T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Front Plates
Erstbestellung von SonderfrontschildernInitial ordering of non-standard front platesPremière commande de plastrons spéciaux
Auftrags-Nr.:Order number:N° de commande :
Position:Item:Poste :
Büro:Office:Bureau :
Bearbeiter:Name:Employé :
Kunde:Customer:Client:
Kundenspez.-Nr.:Customer number:N° client :
Stückzahl:Quantity:Quantité :
DM/Stück:DM/each:Prix unitaire :
Datum:Date:Date :
Non-standard front platesMarking:Front plate with black lettering
Insert textNote the maximum number of characters allowed outside the marked areas!
Type
q FS-SOND-T0 (T3, P1)Height of letters
� 2 characters � 2 characters
4 mm3 mm
q FS-SOND-P3 (T5B, T5)Height of letters
� 2 characters� 2 characters
8 mm5 mm
q
qFS-SOND-TM-EFS-SOND-TM-EZHeight of letters
� 2 characters approx.� 2 characters
3.5 mm3 mm
For P1 and P3 complete only the 270° and 0° positions
Max. number of characters possibleItemDegrees TM-E TM-EZ T0/P1 T5/P3 Dimensions0, 180 5 5 13 13 Type Size of front plate30, 210, 330 8 7 8 845, 135, 225, 315 6 5 6 7 TM-.../E 29
x 29 mm (for frame sizes 30
x 30)60, 120, 240, 300 5 5 5 7 TM-.../EZ(-...) 29
x 29 mm (for frame sizes 30
x 30)90, 270 5 4 4 7 T0, T3, P1 45
x 45 mm (for frame sizes 48
x 48)150 4 4 8 8 P3, T5, T5B 84
x 84 mm (for frame sizes 88
x 88)
Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l´usine) FS.....................................................................................