09/02/2006hv, lv systems status for magnet test1 hardware needed for cc green barrack balcony...

6
09/02/2006 HV, LV systems status for Magnet Tes t 1 Hardware needed for CC Hardware needed for CC Green barrack Balcony barrack W+1 W+2 Y+2 HV HV HV LV EASY LV EASY LV EASY link link link s10 s11 s10 380 V three-phase 380 V three-phase 380 V three-phase

Upload: jessica-barnett

Post on 27-Mar-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 1

Hardware needed for CCHardware needed for CC

Green barrackBalcony barrack

W+1W+2Y+2

HV HV HV

LV EASYLV EASYLV EASY

linklinklink s10

s11

s10

380 V three-phase380 V three-phase380 V three-phase

Page 2: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 2

3 Barrel sectors:

2 Mainframe-LV Easy cables

EASY CRATE 2 HV easy crate

LV EASY 2 LV easy crate

Link box 2 Link boxes

1 Endcap sectors:

1 Mainframe-LV Easy cables

EASY CRATE 1 HV easy crate

LV EASY 1 LV easy crate

Link box 1 Link boxes

HV cables3 cables

1 cable from link to green barrack3 cables from link to green barrack

Balcony barrack

1 HV Main Frame

2 cables from RBC to green barrack

SX5 towers

Page 3: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 3

A1676

HV- x 4

Comm.

SY1527

HV Sector Test in Balcon Barrack

12 A3512A3512

quantiA3512?ci vuole un cavo di communicazione?

Page 4: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 4

A1676

48 V Serv.

Comm. (flat 50 pins)

SY1527

LV Sector Test

LV Rack on tower

A3486

EASY 3000

48 V Power

48 V Serv.

Comm.

A3009

Quanti moduliA1676,quantiA3009,A3486?

Page 5: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 5

HV hardware

SY1527 1A876 5A877 14Crates 3

HV cables

Kerpen cables ~ 100 m 2Novacavi LV cables ~ 100 m 3Novacavi communication cables 2

Cables in counting roomHV cables (SHV connectors) ~ 2 m 28LV cables ~ 2 m 14Communication cables ~ 2 m 5

Cables on wheelsHV cables (SHV connectors) ? m 28LV cables ? m 14Communication cables ? m 5Communication cables ~ 10 cm 9

Page 6: 09/02/2006HV, LV systems status for Magnet Test1 Hardware needed for CC Green barrack Balcony barrack W+1W+2 Y+2 HV LV EASY link s10 s11 s10 380 V three-phase

09/02/2006 HV, LV systems status for Magnet Test 6

LV hardware

SY1527 1A1676A 1-2A3486 2-3EASY 3000 3A3009 5A3050 8A3100 2

Now Missing

A1676 1A3486 1-2Easy 3000 1A3009 4A3050 6A3100 2

LV Cables

CommunicationCables SCEM 04.22.22.750.9 ~ 100 m 2Cables SCEM 04.22.22.750.9 ~ 2-3 m 2-3

48V ServiceCables (connectors PP75 -> PP45) ~ 100 m 2Cable (banana plug -> PP45) ~ 3 m 1Cables (connectors PP45 -> PP45) ~ 2-3 m 3

48V PowerCables (connectors PP75 -> PP75) ~ 2-3 m 3