Suspended Direct/Indirect Luminaire 2, 3, or 4 Lamp T5 or T8 APPLICATION Suspended direct-indirect luminaire with architectural detail. Perforated housing with “checkerboard” pattern used for direct/indirect photometric distribution. Available in 2, 3, or 4 lamp models. Available in 4', 8', and 12' modules for individual or continuous row applications. Ideal for educational, office or commercial applications. Designed to be mounted with cable hangers (RACH series, see spec. sheet 0913-AR), available for a wide variety of ceiling types and mounting applications. Ordering is specified by row configuration. A single catalog number specifies a complete row including hangers. CONSTRUCTION/FINISH Housing constructed from die formed cold-rolled steel. Housing has baked matte white enamel finish. White, acrylic overlay on perforated housing of direct-indirect models provides shielding and masks lamp image and hardware. Center lamps are situated diagonally for even illumination and hanger clearance. Internal aligners require no visible joiner plates for a cleaner appearance. Rugged die-cast aluminum end caps are securely attached with threaded stems and nuts. Luminaires have 48" (4' luminaires), 96" (8' luminaires) and 144" (12' luminaires) mounting centers. ELECTRICAL Certified to UL standards. T5/T8 lamps and energy saving electronic ballast standard. Self-contained emergency battery pack providing 600-700 lumens during emergency mode can be incorporated. Row mount units include pre-wired branch wiring with quick-connect plugs. Branch wiring available in 1 circuit, 2 circuit, 3 circuit, 1 circuit plus emergency, 2 circuit plus emergency, and 1 circuit dimming. JOB INFORMATION 0905.1-AR CATALOG NUMBER NOTES: *See spec sheet 0913-AR for more information. 24 - 24" 48 - 48" 96 - 96" 24" min. MAXIMUM SUSPENSION DISTANCE 1C – 1 Circuit 2C – 2 Circuit 3C – 3 Circuit 1D – 1 Circuit Dimming 1E – 1 Circuit + Emergency 2E – 2 Circuit + Emergency M1 – Support connection at ceiling* M2 – Support connection above ceiling* M3 – Support connection to structure* M5 – Support connection to T-bar* M6 – Non-Seismic Support connection to T-bar* CEILING MOUNT 32 – 32wT8 (48") 28 – 28wT5 (46") 54HO – 54wT5HO (46") LAMP TYPE/WATTAGE WIRING 4 - 4' 8 - 8' 12 - 12' Multiples of 4' (16, 20, 24, etc.) RUN LENGTH P - Direct/Indirect microperforated housing LIGHT DISTRIBUTION 120 277 347 UNV - Universal voltage, 120- 277 volt VOLTAGE OPTIONS 1E7 – One emergency ballast (635 lumens) 2E7 – Two emergency ballasts (635 lumens) CM – Canandian Market DC – Dust cover(s) GLR – Fusing LPT735 – Lamps installed, 70+ CRI 3500K (not included) 2 3 4 NO. OF LAMPS PER CROSS SECTION CC – Aircraft cable w/coiled cord SC – Aircraft cable w/straight cord POWER CORD P RO - Rubato FAMILY RO S - Suspended TYPE S

Upload: edgar-santos-gonzalez

Post on 06-Sep-2014

20 views

Category:

Documents


0 download

TRANSCRIPT

Suspended Direct/Indirect Luminaire

2, 3, or 4 LampT5 or T8

APPLICATION• Suspended direct-indirect luminaire with architectural detail.• Perforated housing with “checkerboard” pattern used for

direct/indirect photometric distribution.• Available in 2, 3, or 4 lamp models.• Available in 4', 8', and 12' modules for individual or

continuous row applications.• Ideal for educational, office or commercial applications.• Designed to be mounted with cable hangers (RACH series,

see spec. sheet 0913-AR), available for a wide variety ofceiling types and mounting applications.

• Ordering is specified by row configuration. A single catalognumber specifies a complete row including hangers.

CONSTRUCTION/FINISH• Housing constructed from die formed cold-rolled steel.• Housing has baked matte white enamel finish.• White, acrylic overlay on perforated housing of direct-indirect

models provides shielding and masks lamp image andhardware.

• Center lamps are situated diagonally for even illuminationand hanger clearance.

• Internal aligners require no visible joiner plates for a cleanerappearance.

• Rugged die-cast aluminum end caps are securely attachedwith threaded stems and nuts.

• Luminaires have 48" (4' luminaires), 96" (8' luminaires) and144" (12' luminaires) mounting centers.

ELECTRICAL• Certified to UL standards.• T5/T8 lamps and energy saving electronic ballast standard.• Self-contained emergency battery pack providing 600-700

lumens during emergency mode can be incorporated.• Row mount units include pre-wired branch wiring with

quick-connect plugs.• Branch wiring available in 1 circuit, 2 circuit, 3 circuit, 1

circuit plus emergency, 2 circuit plus emergency, and 1circuit dimming.

JOB INFORMATION 0905.1-AR

CATALOG NUMBER

NOTES:*See spec sheet 0913-AR for more information.

24 - 24"48 - 48"96 - 96"

24" min.

MAXIMUMSUSPENSIONDISTANCE

1C – 1 Circuit2C – 2 Circuit3C – 3 Circuit1D – 1 Circuit Dimming1E – 1 Circuit + Emergency2E – 2 Circuit + Emergency

M1 – Support connectionat ceiling*

M2 – Support connectionabove ceiling*

M3 – Support connectionto structure*

M5 – Support connectionto T-bar*

M6 – Non-SeismicSupport connectionto T-bar*

CEILING MOUNT

32 – 32wT8 (48")28 – 28wT5 (46")

54HO – 54wT5HO (46")

LAMP TYPE/WATTAGEWIRING

4 - 4'8 - 8'

12 - 12'Multiples of 4'(16, 20, 24, etc.)

RUN LENGTH

P - Direct/Indirectmicroperforatedhousing

LIGHTDISTRIBUTION

120277347UNV - Universalvoltage, 120-277 volt

VOLTAGE

OPTIONS

1E7 – One emergencyballast (635 lumens)

2E7 – Two emergencyballasts (635 lumens)

CM – Canandian MarketDC – Dust cover(s)

GLR – FusingLPT735 – Lamps installed,

70+ CRI 3500K

(not included)234

NO. OF LAMPSPER CROSSSECTION

–––

CC – Aircraft cablew/coiled cord

SC – Aircraft cablew/straight cord

POWER CORD

P

RO - RubatoFAMILY

RO

S - SuspendedTYPE

S

0905.1-AR

DIMENSIONS

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 2850 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'2 Lamp

T8

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- 94 56 40 -- 63 38 - -

134 45 - - -

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 76 76 76 65 65 65 46 461 68 66 63 58 56 54 40 382 63 56 53 54 48 46 34 333 56 50 45 48 42 39 30 284 52 44 38 45 38 34 27 235 47 39 33 40 34 28 23 206 44 34 28 36 29 25 20 177 40 30 25 34 27 22 19 168 36 28 22 32 23 20 17 149 34 25 20 29 22 17 16 13

10 32 23 17 27 20 16 14 11

CATALOG # ROS1C232-4 LAMPS = F32 T8 INPUT WATTS = 62TEST #24999 S/MH= 1.3 BALLAST = ELECTRONIC BALLAST FACTOR = .88

PHOTOMETRIC DATA

Angle End 45 Cross

0 74 74 745 73 73 72

15 69 69 71

25 58 63 6735 45 54 6145 32 48 59

55 20 41 5565 12 31 4775 5 22 36

85 1 15 2795 55 193 205

105 244 498 594

115 450 654 773125 647 771 895135 824 891 972

145 973 1012 1046155 1078 1105 1117165 1171 1174 1173175 1213 1207 1201

ANGLE END 45° CROSS45 173 213 25155 130 205 26065 102 184 25875 64 167 24685 28 164 254

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.75 2850 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 9940x40 100 100 99 9960x30 100 100 99 10060x60 99 99 98 98

100x100 97 98 95 96

DEGREES LUMENS % LAMP % FIXTURE

0-30 56 1.0 1.20-40 89 1.6 2.00-60 160 2.8 3.60-90 231 4.1 5.1

90-180 4256 74.7 94.90-180 4487 78.7 100.0

LLF = .75 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.91 @ 40% RATED LAMP LIFE BF = .88 ELECTRONIC BALLAST & F32 T8 LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 64

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $3.75 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 78.7%

Row mounted units are factory pre-wired with quick-connect plugs forquick and simple row installations.

9"

3"

9"

3"

9"

3"

48" (1219mm)96" (2438mm)

144" (3658mm)

2 LAMP 3 LAMP 4 LAMP

0905.1-AR

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 4400 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'2 Lamp54HO

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- - 99 71 50- 111 67 48 33- 78 47 34 -

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 72 72 72 63 63 63 44 441 66 63 59 56 54 52 38 362 59 55 51 52 47 44 33 303 55 47 42 46 41 36 28 274 50 41 36 42 36 32 26 235 46 38 32 39 33 28 23 206 41 34 28 35 28 23 20 177 39 29 23 33 26 20 17 148 35 27 22 30 23 19 17 149 33 23 19 28 20 17 14 11

10 30 22 17 26 19 14 14 11

CATALOG # ROSP1C254HO-4 LAMPS = F54 T5HO INPUT WATTS = 118TEST #25031 S/MH= 1.3 BALLAST = ELECTRONIC BALLAST FACTOR = 1.00

PHOTOMETRIC DATA

Angle End 45 Cross

0 106 106 1065 105 105 106

15 97 100 103

25 83 90 9535 69 80 9045 49 68 82

55 29 56 7265 17 45 6275 9 31 49

85 2 19 3595 83 245 305

105 355 758 856

115 661 1008 1198125 950 1153 1342135 1200 1305 1428

145 1411 1481 1520155 1578 1612 1624165 1692 1710 1700175 1747 1755 1731

ANGLE END 45° CROSS45 261 285 32655 185 260 31265 140 242 30675 110 206 29085 51 172 270

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.89 4400 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 9940x40 99 99 98 9960x30 99 100 99 9960x60 98 99 97 98

100x100 97 98 95 96

DEGREES LUMENS % LAMP % FIXTURE

0-30 80 0.9 1.20-40 130 1.5 2.00-60 230 2.6 3.40-90 329 3.7 4.9

90-180 6325 71.9 95.10-180 6654 75.6 100.0

LLF = .89 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.95 @ 40% RATED LAMP LIFE BF = 1.00 ELECTRONIC BALLAST & T5HO LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 56

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $4.29 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 75.6%

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 2850 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'3 Lamp

T8

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- 135 81 58 41- 91 55 39 -- 64 39 - -

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 72 72 72 63 63 63 44 441 66 63 59 56 54 52 38 362 59 55 51 51 46 44 33 303 55 47 42 46 40 36 28 264 50 41 36 42 36 32 26 235 46 38 32 39 32 28 23 206 41 33 28 35 28 23 20 177 38 29 23 33 26 20 17 148 35 27 22 29 23 19 17 149 33 23 19 28 20 17 14 11

10 30 22 17 26 19 14 14 11

CATALOG # ROSPMW1C332-4 LAMPS = F32 T8 INPUT WATTS = 88TEST #26600 S/MH= 1.2 BALLAST = ELECTRONIC BALLAST FACTOR = .88

PHOTOMETRIC DATA

Angle End 45 Cross

0 88 88 885 89 88 89

15 81 81 83

25 71 76 7835 58 65 7245 42 54 65

55 26 45 5865 15 36 5075 6 26 40

85 2 15 2695 104 183 187

105 357 605 650

115 671 976 1094125 967 1193 1376135 1232 1366 1509

145 1454 1524 1609155 1624 1654 1698165 1745 1748 1758175 1806 1798 1795

ANGLE END 45° CROSS45 201 214 24755 149 201 24665 112 191 24875 67 176 24785 48 147 223

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.75 2850 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 10040x40 100 100 99 9960x30 100 100 99 10060x60 99 99 98 99

100x100 97 99 96 97

DEGREES LUMENS % LAMP % FIXTURE

0-30 65 0.8 1.00-40 106 1.2 1.60-60 186 2.2 2.90-90 267 3.1 4.1

90-180 6190 72.4 95.90-180 6457 75.5 100.0

LLF = .75 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.91 @ 40% RATED LAMP LIFE BF = .88 ELECTRONIC BALLAST & T8 LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 65

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $3.69 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 75.5%

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 4400 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'3 LampT5 HO

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- - 140 100 70- - 94 67 47- 111 66 47 33

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 68 68 68 58 58 58 40 401 61 58 56 54 51 48 35 342 56 52 47 48 45 40 30 283 52 45 40 44 39 34 27 254 46 40 34 40 34 29 23 205 42 34 29 36 30 26 20 196 39 32 26 34 27 23 19 167 35 28 23 30 23 20 17 148 34 25 20 28 22 17 16 139 30 23 17 27 20 16 14 11

10 28 20 16 25 17 14 13 10

CATALOG # ROSPMW1C354-4 LAMPS = F54 T5HO INPUT WATTS = 164TEST #26114 S/MH= 1.3 BALLAST = ELECTRONIC BALLAST FACTOR = 1.00

PHOTOMETRIC DATA

Angle End 45 Cross

0 112 112 1125 110 110 112

15 101 102 106

25 89 95 10135 71 81 9145 52 70 82

55 32 56 7265 18 46 6475 9 33 51

85 2 21 3495 112 378 372

105 454 1037 1186

115 910 1479 1751125 1329 1722 2029135 1701 1934 2158

145 2009 2153 2264155 2250 2334 2388165 2416 2447 2466175 2500 2513 2508

ANGLE END 45° CROSS45 248 278 31255 184 250 30565 135 244 31775 101 224 31585 48 206 291

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.89 4400 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 9940x40 99 100 99 9960x30 100 100 99 10060x60 99 99 98 98

100x100 96 98 94 96

DEGREES LUMENS % LAMP % FIXTURE

0-30 83 0.6 0.90-40 134 1.0 1.40-60 237 1.8 2.50-90 344 2.6 3.6

90-180 9084 68.8 96.40-180 9428 71.4 100.0

LLF = .89 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.95 @ 40% RATED LAMP LIFE BF = 1.00 ELECTRONIC BALLAST & T5HO LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 57

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $4.21 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 71.4%

DAY-BRITE LIGHTING • www.daybritelighting.com776 South Green Street • Tupelo, Mississippi 38804 • PH: (662) 842-7212 • FAX: (662) 841-5501CANADIAN DIVISION189 Bullock Drive • Markham, Ontario L3P 1W4 • PH: (905) 294-9570 • FAX: (905) 294-9811 a Genlyte company

0905.1-AR ©2007 DAY-BRITE LIGHTINGDB 02-07DAY-BRITE RESERVES THE RIGHT TO

MAKE CHANGES WITHOUT NOTICE.

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 2850 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'2 Lamp

T8

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- - 110 79 55- 123 74 53 37- 87 52 37 -

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 73 73 73 64 64 64 44 441 67 64 60 57 55 53 39 362 60 56 51 52 47 45 34 303 56 48 44 47 41 38 29 274 51 42 36 42 36 33 26 235 46 38 32 40 33 28 23 206 42 34 28 35 28 25 20 177 39 29 25 33 26 22 19 148 35 27 22 30 23 19 17 149 33 25 19 28 22 17 14 11

10 30 23 17 27 20 14 14 11

CATALOG # ROSP1C432-4 LAMPS = F32 T8 INPUT WATTS = 122TEST #24994 S/MH= 1.3 BALLAST = ELECTRONIC BALLAST FACTOR = .88

PHOTOMETRIC DATA

Angle End 45 Cross

0 110 110 1105 110 108 109

15 101 103 105

25 97 95 10035 70 84 9245 50 71 84

55 30 59 7765 19 49 6875 10 34 53

85 4 21 3795 163 212 206

105 520 708 707

115 948 1243 1260125 1349 1643 1742135 1715 1956 2040

145 2020 2196 2266155 2263 2363 2403165 2419 2468 2478175 2505 2517 2505

ANGLE END 45° CROSS45 270 316 35755 195 296 36365 162 291 37475 128 258 36285 112 229 348

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.75 2850 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 9940x40 99 99 98 9960x30 99 100 99 9960x60 99 99 97 97

100x100 96 97 94 95

DEGREES LUMENS % LAMP % FIXTURE

0-30 84 0.7 1.00-40 136 1.2 1.50-60 240 2.1 2.70-90 346 3.0 3.9

90-180 8415 73.8 96.10-180 8761 76.9 100.0

LLF = .75 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.91 @ 40% RATED LAMP LIFE BF = .88 ELECTRONIC BALLAST & T8 LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 63

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $3.81 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 76.9%

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 4400 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

4'4 Lamp54HO

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 ft-c 30 ft-c 50 ft-c 70 ft-c 100 ft-c

- - - 119 83- - 112 80 56- 132 79 57 40

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 60 60 60 53 53 53 36 361 56 53 51 47 46 44 32 302 51 46 42 42 40 36 28 263 46 40 35 39 34 30 23 224 41 35 30 35 30 27 22 195 38 32 27 33 27 23 19 176 34 28 23 29 23 20 17 147 32 25 20 28 22 17 14 138 29 23 17 26 20 16 14 119 28 20 16 23 17 14 13 10

10 26 19 14 22 16 13 11 8

CATALOG # ROSP1C454HO-4 LAMPS = F54 T5HO INPUT WATTS = 228TEST #25026 S/MH= 1.3 BALLAST = ELECTRONIC BALLAST FACTOR = 1.00

PHOTOMETRIC DATA

Angle End 45 Cross

0 125 125 1255 124 124 124

15 114 114 115

25 109 108 11335 80 92 10245 58 78 93

55 35 65 8365 24 54 7375 13 38 58

85 3 23 4095 135 338 371

105 611 1133 1180

115 1133 1722 1963125 1617 2079 2429135 2051 2360 2653

145 2417 2621 2791155 2709 2846 2921165 2892 2976 2989175 2989 3033 3022

ANGLE END 45° CROSS45 309 327 36955 223 302 35965 198 291 36075 159 253 34485 76 208 309

• 80-50-20 Reflectances (Ceiling-Wall-Floor)• LLF = 0.89 4400 Lumens/Lamp very clean• Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 100 100 99 9940x40 99 99 98 9960x30 99 100 99 9960x60 99 99 97 98

100x100 96 98 94 96

DEGREES LUMENS % LAMP % FIXTURE

0-30 97 0.5 0.90-40 155 0.9 1.40-60 271 1.5 2.40-90 392 2.2 3.5

90-180 10843 61.6 96.50-180 11235 63.8 100.0

LLF = .89 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.95 @ 40% RATED LAMP LIFE BF = 1.00 ELECTRONIC BALLAST & T5HO LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = 49

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $4.90 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 63.8%