1 2 3 4 240 c)540 240 c)540 1zsc026120-aal b en 1/2 document id. revision language sheet vucgr,...
TRANSCRIPT
This document is issued by means of
a computerized system.
The digitally stored original is ele
ctronically approved. The
approved document has a date entered
in the `Approved'-field.
A manual signature is not required.
Drawing sheet ISO 5457-A4T rev A
We reserve all rights in this document and in the information contained
therein. Reproduction, use or disclosure to third parties without express
authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.
D
C
B
E
F
1 2 3 4
C
C
205
C
27
D 470
A
200
223
600
710
24x �n�
15
B1097
111
126
100
332
30
255 255
98
6 45
4x 14
255
C/L Top flange80
C/L Diverter switch30
460 730
821
671
60
200
200
723
43
()
373
100
100
373
100
740
190
552
600
435 381
INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650
750 750 1050A 2451 a)2751 a)2231 a)2531 a)Dimen-
sionsin mm
B 1354 a)1654 a)1134 a)1434 a)C 119 a)c)119 a) 119 a)c)119 a)D 240 c) 540 240 c) 540
1/2ENB1ZSC026120-AAL
SheetLanguageRevisionDocument Id.
VUCGR, VUCGD B(2ph) XXXX/450, 800/F 8-9,12-13 Pos
TAP-CHANGER
Title
DIMENSION DRAWING PGCO/TK2016-11-29
Document KindResponsible departmentDate / Approved
Diverter switch terminal, no 30.
1) Shielding rings for insulating levels 650, 750 and 1050 kV only. Shielding rings diameter additional 6 mm for insulating level 1050 kV only.2) Shields only for insulating levels 650, 750 and 1050 kV.
a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity. Please refer to Technical Guidec) Not applicable for 380 kV
V 2..12.
V 2..12.
H 1..13.
1
1
1
C/L Tap selector
H 1..13.
21
22
22
21
Lower ring notfor short version
Transformer flange
2
C - C
This document is issued by means of
a computerized system.
The digitally stored original is ele
ctronically approved. The
approved document has a date entered
in the `Approved'-field.
A manual signature is not required.
Drawing sheet ISO 5457-A4T rev A
We reserve all rights in this document and in the information contained
therein. Reproduction, use or disclosure to third parties without express
authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.
D
C
B
E
F
1 2 3 4
250140
260
85
920
95
95
25
165
165
60
60
135
135
90
490
12x 18
70�$�
30�$�
40�$�
72�$�
36�$�
36�$�
72�$�
36�$�36�$�
30�$�
40�$�
36�$�
36�$�
36�$�
36�$�
36�$�
36�$�
36�$�36�$�
651
1081
48
25
44
13
189
70�$�
340
260 41517,5
46
55
27,5
13
R315
ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part:54920103-1Accessories:54920103-2Motor Drive BUL2:1ZSC004106 -AAEMotor Drive BUE:1ZSC004106 -AAH or -AAJExternal Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1Holes for mounting of support forcleats and leads:1ZSC026099
2/2ENB1ZSC026120-AAL
SheetLanguageRevisionDocument Id.
VUCGR, VUCGD B(2ph) XXXX/450, 800/F 8-9,12-13 Pos
TAP-CHANGER
Title
DIMENSION DRAWING PGCO/TK2016-11-29
Document KindResponsible departmentDate / Approved
D
D-D
B-B
8-9 POSITIONS
1
2/3
4/5
6/7
8/9
20
21
22
A - A
V
H
R297
R297
Current Collector
12-13 POSITIONS
1
2/3
4/5
6/7
8/9
10/1112/13
20
21
22
A - A
V
H
D
T=15
T=26