1. 2 3 4 megger - substation overview 5 170 product groups, 2600 products

105
1

Upload: winfred-bruce

Post on 17-Dec-2015

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

1

Page 2: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

2

Page 3: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

3

Page 4: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

4

Megger - Substation overview

Page 5: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

5

170 product groups, 2600 products

Page 6: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

6

MEGGER Insulation testers, fibre optic testing MULTI-AMP Circuit breaker test tests BIDDLE High voltage test sets AVO Multimeters,Training, software DUCTER Ohm meters FOSTER Oil test sets STATES Terminal blocks METROSONICS Critical systems monitoring PROGRAMMA Relay/ Circuit Breaker/ Battery Testing PAX DIAGNOSTIC Transformer, Insulation Products

Megger Brand Names

Page 7: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

7

IEC 61850 STANDARD IN SUBSTATION AUTOMATION

Main purpose of the standard is to achieve interoperability among different devices from different vendors within the same substation.

Page 8: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

8

IEC 61850 STANDARD IN SUBSTATION AUTOMATION

Page 9: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

9

IEC 61850 STANDARD IN SUBSTATION AUTOMATION

What is Substation Automation?

We need to know what we are talking about, in order to understand what needs to be standardized.

Page 10: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

10

Page 11: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

11

Page 12: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

12

THE POWER SUBSTATIONIn a substation there are Primary Equipments:

Page 13: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

13

THE POWER SUBSTATION

The Primary equipments in the Substation need to be ”controlled”.

The word CONTROL in a substation has nothing to do with Process Control, where the word CONTROL is usually associated to ”feedback systems”:

Page 14: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

14

THE POWER SUBSTATION

Page 15: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

15

THE POWER SUBSTATION

Busbar change. Load is on Busbar 2

Page 16: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

16

THE POWER SUBSTATION

Busbar change. Connecting Busbar 1 to Busbar 2

Page 17: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

17

THE POWER SUBSTATION

Busbar change: Connecting the Feeders to Busbar 1

Page 18: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

18

THE POWER SUBSTATION

Busbar change: Disconnecting feeders from Busbar 2

Page 19: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

19

THE POWER SUBSTATION

Busbar change: Disconecting Busbar 2 from the system

Page 20: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

20

THE POWER SUBSTATION

Busbar change. Busbar 1 in service

Page 21: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

21

THE POWER SUBSTATION

Page 22: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

22

THE POWER SUBSTATION

One very simple interlocking:

Earthing Switch and Disconnector

I can OPEN / CLOSE the Disconnector ONLY if the Earthing Switch is OPEN.

If the Earthing Switch is CLOSED I cannot operate the Disconnector.

Page 23: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

23

THE POWER SUBSTATION

EARTHING SWITCH CLOSED

Page 24: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

24

THE POWER SUBSTATION

EARTHING SWITCH OPEN

Page 25: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

25

THE INTERLOCKING SYSTEM

Page 26: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

26

A Local Action (open/close) may require:

THE INTERLOCKING SYSTEM

Remote information (from different bays)

Local information (from the same bay)

Page 27: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

27

Page 28: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

28

THE INTERLOCKING SYSTEM

Page 29: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

29

THE INTERLOCKING SYSTEM

Page 30: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

30

THE IEC 61850 INTERLOCKING SYSTEM

Page 31: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

31

CONTROL / INTERLOCKING in an IEC 61850 substation

Page 32: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

32

IEC 61850 Standard

Page 33: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

33

THE POWER SUBSTATION

In a substation there are Primary Equipments…..

Page 34: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

34

THE POWER SUBSTATION

… that must be protected.

Page 35: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

35

THE PROTECTION RELAYS

Page 36: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

36

THE PROTECTION RELAYS

Page 37: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

37

THE PROTECTION RELAYS

The circuit breaker opens and interrupts the fault current. The relay sees no fault conditions anymore and it resets. Circuit breaker remains open, the fault has been cleared.

Page 38: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

38

THE PROTECTION SYSTEM

Page 39: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

39

THE PROTECTION SYSTEM

Radial Feeders: No communication

Page 40: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

40

THE PROTECTION SYSTEM

Radial Feeders: No communication

Page 41: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

41

THE PROTECTION SYSTEM

Radial Feeders: No communication

Page 42: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

42

THE PROTECTION SYSTEM

Radial Feeders: No communication

Page 43: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

43

THE PROTECTION SYSTEM

Radial Feeders: Communication

Page 44: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

44

THE PROTECTION SYSTEM

Radial Feeders: Communication

Page 45: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

45

THE PROTECTION SYSTEM

Radial Feeders: Communication

Page 46: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

46

THE PROTECTION SYSTEM

Radial Feeders: Communication

Page 47: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

47

PROTECTION signals (Trip, Block, Acceleration..) are sent through the station bus.Horizontal communication

IEC 61850 APPLICATION: PROTECTION

Page 48: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

48

GOOSE = Generic Object Oriented System Event.

Is an unacknowledged multicast message that is repeated with a certain strategy allowing the supervision of the Horizontal Communication.

GOOSE communication for PROTECTION and CONTROL

Page 49: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

49

GOOSE or Contact (Conventional) ?

Page 50: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

50

GOOSE or Contact (Conventional) ?

Page 51: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

51

GOOSE or Contact (Conventional) ?

Page 52: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

52

GOOSE or Contact (Conventional) ?

Page 53: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

53

IEC 61850 Standard

Page 54: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

54

Page 55: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

55

Proprietary communication protocols were / are still available.Handling correctly all protocols was and is still a challenge

”BEFORE standardisation”: REPORTING TO SCADA / RTU

Page 56: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

56

”BEFORE”: PROTOCOL CONVERTERS / IMPLEMENTATIONS

Page 57: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

57

IEDs from different vendors can exchange and use information over a common communications media. No need to have protocol converters.Reporting: Vertical Communication.

IEC 61850 APPLICATION: REPORTING TO SCADA / RTU

Page 58: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

58

IEC 61850 APPLICATION: SCADA/RTU COMMUNICATION

The communication between SCADA / RTU and the IEDsis defined in the IEC 61850 standard (MMS / FTP).

Data exchanged can be:

• Control (operating primary objects)• Log• Reporting of events• Disturbance Files Upload

Page 59: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

59

IEC 61850 Standard

Page 60: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

60

IEC 61850: NETWORK TOPOLOGY

The data traffic runs on Ethernet, 100 Mbit/s.

This means that in the IEC 61850 substation there are Ethernet switches.

Protection and Control signals are dependent on the correct functionality of the communication system, which has in the Ethernet switches one of its most important factors.

Page 61: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

61

IEC 61850: NETWORK TOPOLOGY

Star

Ring

Page 62: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

62

IEC 61850 Standard

Page 63: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

63

IEDs and Substations are described through XML files.The “IEC 61850 language used in the XML files” is called SCL language.

SCL: Substation Configuration Language.

IEC 61850: The SCL language

Page 64: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

64

IEC 61850: The SCL language (IED Modelling)

Page 65: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

65

Bay A Bay Unit (IED)

PTRC (Trip, Operate)

IEC 61850: The SCL language (IED modelling)

Page 66: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

66

Bay Unit (IED)

PTRC (Trip, Operate)

SCLBay A

IEC 61850: The SCL language (IED modelling)

Page 67: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

67

Bay Unit (IED)

PTRC (Trip, Operate)

SCLBay A

IEC 61850: The SCL language (IED modelling)

Page 68: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

68

Bay Unit (IED)

PTRC (Trip, Operate)SCL

Bay A

IEC 61850: The SCL language (IED modelling)

Page 69: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

69

SCLSCL

IEC 61850: The SCL language (IED modelling)

It is possible to “structure” the Logical Nodes, and group them under different Logical Devices.The “rules” of this structure are described in the XML file.

Page 70: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

70

The SCL file also describes what the IED can do (services). In this case it seems that the IED cannot offer upload of disturbance recorder file, as the “FileHandling Service” is not listed:

IEC 61850: Services (IED modelling)

While this IED allows to upload the disturbance recorder files (FileHandling Service” is listed):

Page 71: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

71

Depending on the information they carry, there are different types of SCL files:

ICD (IED Capability Description)CID (Configured IED Description)SCD (Substation Configuration Description)

SSD (System Specification Description)

IID (Instantiated IED Description)SED (System Exchange Description)

IEC 61850: Different SCL files

Page 72: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

72

IEC 61850 Standard

Page 73: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

73

IEC 61850: Engineering Process

Page 74: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

74

An IEC 61850 substation is described by one special SCL file, called SCD file (Substation Configuration Description).

IEC 61850: Engineering Process

Page 75: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

75

IEC 61850: Engineering Process

There are software tools that can extract engineering information from the SCD file and represent them in a comfortable way to the user:

Page 76: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

76

IEC 61850: Engineering Process

REPORTING Vertical Communication

All the IEC 61850 devices (IEDs) describe themselves withhelp of the SCL language.

SCL information from all IEDs are integrated into theIEC 61850 Engineering Tool.

Page 77: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

77

IEC 61850: Engineering Process

The SCADA system is also IEC 61850 compliant, and it can read the SCD files understanding how the substation looks like, which IEDs are present and which information they send to the SCADA system .

SCADA / RTU Vertical Communication

Page 78: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

78

IEC 61850: Engineering Process

GOOSE Horizontal Communication

In the SCL file there is written which IED talks to which IED.The standard messages among IEDs in the same substation are called

GOOSE messages (Generic Object Oriented Substation Event).GOOSE messages can contain protection application information (TRIP, Block etc.).

Page 79: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

79

IEC 61850: Engineering Process

The IEC 61850 Engineering Tool

One IEC 61850 Engineering Tool is in principle a “software that handles SCL files”.

The initial SCL files are provided by the IED vendor software tools, and they are called ICD files (IED Capability Description).

The ICD files are imported in the IEC 61850 Engineering TOOL and GOOSE – Reporting information are added for each IED, creating the so called SCD file (Substation Configuration Description).

The SCD file is then exported from the Engineering Tool. IED vendor tools will import that file and will download in the IEDs the IEC 61850 information that are written in the SCD files.

Page 80: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

80

IEC 61850:Engineering Process

Page 81: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

81

IEC 61850: Engineering Tools

Documentation

The SCD file describes the substation in IEC 61850 language (SCL).The IEC 61850 tool is able to elaborate such information and to show it in human readable format, like a PDF file.

Page 82: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

82

IEC 61850: Engineering Tools

Page 83: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

83

IEC 61850 Standard

Page 84: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

84

PROCESS BUS

Sampled Values(SV)9-2

Merging Units (MU)

IEC 61850-9-2NCIT

PROCESS BUS

Page 85: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

85

FULLY IEC 61850 SUBSTATION

Page 86: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

86

THE RELAY

Page 87: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

87

Replacement of BO cards

GOOSE OUT

Page 88: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

88

Replacement of BI cards

GOOSE OUT

GOOSE IN

Page 89: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

89

GOOSE OUT

GOOSE IN

Page 90: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

90

THE IEC 61850-8-1 IED

GOOSE IN GOOSE OUT

IEC 61850-8-1 Station Bus

Page 91: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

91

Replacement of analog cards + A/D conversion

GOOSE IN GOOSE OUT

IEC 61850-8-1 Station Bus

SAMPLED VALUES (SV)

Page 92: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

92

GOOSE IN GOOSE OUT

IEC 61850-8-1 Station Bus

SAMPLED VALUES

Page 93: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

93

THE FULLY IEC 61850 COMPLIANT IED

GOOSE IN GOOSE OUT

IEC 61850-8-1 Station Bus

SAMPLED VALUES

IEC 61850-9-2Process Bus

Page 94: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

94

WHERE ARE THE SAMPLED VALUES COMING FROM?

SA

MP

LE

D V

AL

UE

S

Page 95: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

95

Merging Units

Page 96: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

96

Merging Units

Page 97: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

97

IEC 61850 Standard

Page 98: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

98

IEC 61850 Standard

Page 99: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

99

IEC 61850: TESTING

How do we test all of this?

How do we test the Network Topology (Switches)?

How do we test the Vertical Communication to SCADA?(IEC 61850-8-1, MMS, Reporting)

How do we test Interlockings?(IEC 61850-8-1 GOOSE)

How do we test Protection Schemes?(IEC 61850-8-1 GOOSE and IEC 61850-9-2 SV)

Page 100: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

100

IEC 61850: TESTING

Page 101: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

101

Information about IEC 61850KTH: Kungliga Tekniska Högskolan

University courses on IEC 61850for SA (Substation Automation)

Page 102: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

102

Information about IEC 61850Tissues (Technical Issues) database

www.tissues.iec61850.comIEC 61850 standard is a dynamic standard!. You must follow it!

Page 103: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

103

IEC 61850 Blog

Information on new IEC 61850 documents

Information on IEC 61850 events

Information on new instruments and techniques on the IEC 61850

www.blog.iec61850.com

Competent and fast up to date blog on IEC 61850

Information about IEC 61850

Page 104: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

104

Information om IEC 61850Elforsk www.elforsk.se

Page 105: 1. 2 3 4 Megger - Substation overview 5 170 product groups, 2600 products

105

Megger http://www.megger.comIEC 61850 test equipment, tools and litterature

Information om IEC 61850