OREGON STATE UNIVERSITY (OSU) BATCHELLER HALL ADA ASSESSMENT & SURVEY

Upload: others

Post on 26-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OR

EG

ON

STA

TE U

NIV

ER

SITY

(O

SU)

BATCHELLER HALL

ADA ASSESSMENT & SURVEY

Page 2: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

Sacramento Office

770 L Street, Suite 950 Sacramento, CA 95814

Tel: 916.669.8750 Fax: 888.211.7441

Silicon Valley Office

2225 E. Bayshore Road, Suite 200

Palo Alto CA 94303 Tel: 866.694.7637

www.szs- consu lting.com

January 9, 2015

Angelo Gomez Executive Director

Office of Equity and Inclusion Oregon State University 330 Snell Hall

Corvallis, OR 97331-2128

Re: ADA Accessibility Survey and Assessment – Batcheller Hall

Dear Angelo,

We are pleased to submit this report for the Batcheller Hall. This report is part of our project to

provide a Campus Accessibility Survey and Assessment for Oregon State University. It is our

hope that this report w ill assist OSU in improving access to people w ith disabilities to campus

facilities.

SZS has been pleased to be a part of this effort to evaluate campus buildings using federal and

state statutes and regulations, as w ell as universal design principles in order to create

performance standards that w ill guide design, construction and maintenance on campus.

We look forw ard to discussing our f indings w ith your team.

Regards,

Syroun Z. Sanossian, Principal

SZS Consulting Group LLC

Page 3: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

TABLE OF CONTENTS

1. EXECUTIVE SUM M ARY OF FINDINGS p. 1

a. Pedestrian Facilities and Exterior

Spaces Analyzed p. 2

b. Building Entrances p. 3

2. INTERIOR SPACES

Basement p. 4

First Floor p. 5

Second Floor p. 6

Third Floor p. 6

3. BARRIER DATA RECORDS

Exterior Area Barriers p. 7

Interior Area Barriers p. 14

Cost Estimate p. 198

Page 4: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

1

1. EXECUTIVE SUMMARY OF FINDINGS

The field investigation for the interior spaces began on March 4, 2014. The exterior site

elements w ere assessed originally as part of the pedestrian facilities assessment in June-

September 2011 and are included as an essential part of this report. Images of each

physical element identif ied in this report w ere captured in HD digital photos w hile manual

measurements w ere taken to establish as-built conditions to facilitate the process of cost

estimating. Digital photographs are provided w ithin the report for each barrier to access , to

facilitate the review of the data collected. We have found that technical data can be diff icult

to interpret w ithout a visual component; the photos provide a clear connection betw een the technical data and each barrier to access.

The Batcheller Hall is a historic structure and many barriers to access w ere identif ied in the

building. That is quite typical, as barriers to access exist in virtually every building, w hether new or existing.

No “perfect” building exists in the real w orld.

This ADA Assessment and Survey report is intended to not only identify barriers to access,

but to provide solutions. The basis for this ADA Assessment and Survey process is the

underlying desire on the part of OSU to improve access by relying on higher standards than

the minimum requirements in state and federal building codes. SZS intends to provide the

information in this report in a clear and easy to understand format. The information in this

report is compiled for use by designated OSU staff and other interested persons, so the

content is designed to be understood by professionals and laymen alike.

The findings presented are both narrative and technical in nature; barriers to access identif ied during the f ield investigation process are documented in tw o w ays;

1. Narrative Analysis: The analysis of f indings is contained in an executive summary in a

narrative form that not only describes each type of barrier identif ied but also provides a

discussion that analyses the functionality of physical elements. We also provide the

reasoning and research behind the identif ication of barriers that conflict w ith universal

design principles. This analysis may be accompanied by digital photographs or diagrams, w here applicable.

NOTE: Understanding building function and usage is essential w hen interpreting the f indings held in this report. The narrative is intended to facilitate this process.

2. Barrier Data Records: Individual barriers to access are entered into the SZS database

so that technical information on the barriers can be provided as barrier data records.

These barrier data records include digital photographs of each barrier identif ied, code

references that determine the barrier to access, as-built measurements, barrier severity

ratings, budgetary cost estimates, recommended solutions for barrier removal and a

priority for barrier removal. The information is formatted w ith tw o barriers on each report

page.

In order to consolidate the report data, some of the more typical barriers found in multiple

locations have been grouped w ithin the barrier data records w ith a description of the

locations in w hich they w ere found.

Page 5: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

2

A. Pedestrian Facilities and Exterior Spaces Analyzed

This report provides information on campus pedestrian facilities that serve Batcheller Hall.

Many physical elements are part of the comprehensive w hole that creates a pedestrian

facility. The fundamental elements evaluated as to w hether they provide accessible

pedestrian facilities include the follow ing:

Sidew alks

Walkw ays

Ramps

Curb Ramps

Blended Transitions

Signalized Intersections

Stairw ays (94% of people w ith disabilities are not mobility impaired)

Benches and other Seating Elements

Picnic Facilities

The descriptions provided for physical elements in this report are intended to clearly

describe the differences betw een each physical element, such as w hen a pedestrian route

is a sidew alk, rather than a w alkw ay. The descriptions are intended to explain how the

elements interact to form a cohesive pedestrian facility. Other more specif ic information

described w ithin this section intends to provide guidance on determinations made in this

report.

The key to providing accessible pedestrian facilities is in recognizing that different people

w ith disabilities have different needs. Setting policies that speak to the entire group is

essential, rather than focusing one particular subset of the overall group. Universal design

principles govern here – physical elements should be usable to everyone that visits campus

w ithout having to resort to any adaptation or specialized design.

In summary, an accessible route exists w ithin a building, property boundary or interior

space and is separate from the PROW. Pedestrian w alkw ays are similar to sidew alks as

paved surfaces improved for use by pedestrians but w alkw ays are not located along or

adjacent to the curb line, gutter or roadw ay and w alkw ays are generally not considered part

of the PROW. The pedestrian facility is the combination of the PROW and the accessible

route, w hich functions as a w hole to provide pedestrian access to facility entrances.

Batcheller Hall is considered a historic structure. As a public building governed by the ADA

Standards, Batcheller Hall should have at least one accessible entrance, but all physical

entrances at the building are by w ay of stairs. The building is located on the north side of

SW Campus Way betw een Covell Hall and Dearborn Hall. Although the only direct vertical

access provided to the building is in the form of stairw ays, an interior corridor connection to

Covell Hall provides a w ay for people w ith mobility impairments to enter Covell Hall, travel

through that building and reach Batcheller Hall although the pedestrian route is in excess of

Page 6: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

3

200 linear feet. According to the ADA Standards Advisory Section 405.2, to accommodate

the w idest range of users, the length of pedestrian routes can be a concern for those

individuals for w hom distance presents a greater barrier than steps, e.g., people w ith heart

disease or limited stamina. Also, according to the ADA Standards Section 403.5.3 Passing

Spaces, an accessible route w ith a clear w idth less than 60 inches shall be provided to

allow passing spaces at intervals of 200 feet maximum. Passing spaces shall be either: a

space 60 inches minimum by 60 inches minimum; or, an intersection of tw o w alking

surfaces providing a T-shaped space w here the base and arms of the T-shaped space

extend 48 inches minimum beyond the intersection. The provision of a passing space

throughout this lengthy path of travel betw een the accessible entrance of Covell Hall and

Batcheller Hall may be diff icult to maintain over time. It is important to ensure that

maintenance staff understands that the corridors used for this path of travel are kept clear.

Where this connection route remains accessible, Batcheller Hall can be considered to have

an accessible route provided w ithin the site from accessible parking spaces and accessible

passenger loading zones; public streets and sidew alks; and public transportation stops to

the accessible building or facility entrance they serve1 as compared to the 2010 ADA

Standard for Accessible Design. Details on barriers identif ied in that route are provided

w ithin the ADA Assessment and Survey of the pedestrian f acilities provided as a separate

report, as w ell as in the follow ing records. Please see the barrier data records for details.

B. Building Entrances

The building is located along SW Campus Way. No parking is provided on-site. Pedestrian

entrances are provided at the north and south sides of the building, as described above. No

International Symbol of Accessibility (ISA) directional sign is provided at these locations or

ground floor entrance doors leading to stairw ays indicating that the accessible route to this

building is provided through Covell Hall. This signage is essential.

1 2010 A DA Standards for A ccessible Design, Section 206.2.1 S ite A rriv al Points

Page 7: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

4

INTERIOR SPACES

BASEMENT

Batcheller Hall is a three-story building including a basement. The building is pre-ADA

building and entrance to the building is provided through Covell Hall, as discussed above.

The basement houses an ergonomics laboratory, classroom, computer lab and a men’s

restroom. Barriers identif ied in the basement include entrance doors to classrooms or

laboratories that lacked accessible signage, door hardw are, door closer operating

force/sw eep period w here door closers w ere installed and w here doors w ere identif ied w ith view panels, the panels w ere not accessible to short people or w heelchair users.

In many instances, entry doors lacked accessible maneuvering clearance as either a result

of the original design or due to the location of cabinets or other items that encroached into

the space needed by w heelchair users to maneuver. The lack of accessible maneuvering

clearance may necessitate the installation of automatic door opening devices at entrance

doors to classrooms and laboratories in many locations. Light sw itches and outlets w ere

identif ied as non-accessible throughout the f loor. Accessible desks w ere not provided and

strobe devices used to notify people w ith hearing impairments of an alarm actuation w ere not identif ied in these spaces.

A computer lab on this f loor lacked accessible w orkstations and a classroom w ith f ixed

seats also lacked accessible desks w here at least 5% should be accessible. The

ergonomics lab w as identif ied w ith no accessible desks, protruding hazards and an exit

door from the lab lacked accessible hardw are and maneuvering clearance.

Tactile signage w as not identif ied in any location on this f loor. No drinking fountains w ere

identif ied in the basement and the central corridor w as identif ied w ith non-accessible

signage, protruding objects and exit doors in the corridor lacked tactile exit signs or

accessible operating force, door hardw are or clear w idth adequate to allow a person using

a mobility assist device to enter the building on this level. A drainage grate located in the

center of the corridor created a trip hazard and uneven w alking surface in the corridor. Fire

pulls in the basement w ere not f ist operable and the actuating devices w ere not located w ithin accessible reach ranges.

The north entry and lobby w ere identif ied as lacking accessible signage including lobby

informational signage and protruding objects w ere identif ied in those spaces. Doors w ere

identif ied w ith non-accessible operating force, view

panels to high for use by short people, door stops and

an uneven surface w ithin the bottom 10” of each door

could create trap conditions for people w ho use

w heelchairs. Signage indicating the location of the emergency exit w as also not provided.

The north exit stairw ay exit passage lacks accessible

doors, door operating force and doormats in the

pathw ay are also not secured. The stairw ay handrails

appeared to be original to the building and w ere not

accessible. The stairw ay tread surface appeared to

be slick and may lack slip resistance although the surface w as not rigorously tested.

Page 8: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

5

A men’s restroom w as located w ithin the central corridor. The sanitary facility w as a multi-

accommodation restroom. The entry door lacked accessible signage, the door operating

force w as excessive, and the door hardw are w as not accessible. Signage posted above the

entry door lacked characters that could be view ed from a distance. The restroom lacked an

accessible lavatory, urinal or toilet. Maneuvering clearance in the room w as not adequate to

allow a person using a w heelchair to pull in front of a lavatory or enter a toilet stall.

Dispensers created protruding objects w ithin the circulation route in the room, w hich

presents a barrier to the visually impaired and strobe devices used to notify people w ith hearing impairments of an alarm actuation w ere not identif ied in these spaces.

The central corridor w as identif ied w ith non-accessible signage, protruding objects and exit

doors in the corridor lacked tactile exit signs or accessible operating force and door hardw are. A phone and f ire pull w ere not located w ithin accessible reach ranges.

The Hub study area lacked accessible entry doors, signage and clear f loor space in the

w aiting area. The advising areas w ere identif ied w ith accessible desks and maneuvering

clearance in the public areas, but tables and study carrels w ithin the Hub w ere not accessible.

FIRST FLOOR

A w omen’s single accommodation toilet room is located on the intermediate stairw ay

landing in the north stairw ay. The door signage w as not accessible, the entry door w as too

narrow for someone using a mobility assist device to enter and the existing square footage

of the room is not adequate for accessibility. More importantly, the restroom is not located

on an accessible route, although it is the only restroom on the f irst f loor. The stairw ay

serves as the north entry point for the building. Fire pulls in the stairw ell and central corridor

w ere not f ist operable and the actuating devices including light sw itches w ere not located

w ithin accessible reach ranges. An electrical panel located directly in the emergency exit

path lacked detectable w arnings, and the stairw ay clear w idth may not be adequate for

emergency exiting considering the occupancy load in classrooms and laboratories on upper

f loors.

The entry doors at the north and south stairw ays w ere identif ied w ith ISA signs (stickers)

w ithin the door view panels, but people w ould have to travel up the stairs to view the sign

and find that the accessible entrance is located elsew here. It is recommended to provide

ISA directional sign in a location w here people approaching the building can make use of

information w ithout having to retrace their steps.

A public phone in the central lobby w as not located w ithin accessible reach range.

Electrical outlets w ere identif ied along the baseboard a few inches from the f loor w here

people using w heelchairs could not reach them. A drinking fountain intended for w heelchair

access w as located in the lobby but it w as not located w ithin an alcove. It w as also

mounted w ith knee clearance that could prevent people using w heelchairs from pulling

under the fountain. A shelf mounted next to the fountain also has a sharp metal edge that

protrudes into the circulation route in the lobby and no detectable w arning is provided.

Page 9: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

ADA Assessment & Survey Batcheller Hall

6

No elevator is provided in the building. Barriers identif ied in the f irst f loor w ere commonly

identif ied throughout the building in common use areas. Classrooms and laboratory space

in the building lacked entry doors that operated w ith accessible opening force and lacked

accessible door view panels and strike edge clearance necessary for people using

w heelchairs to maneuver close enough to the door

to operate the door hardw are. Controls and

mechanisms such as pencil sharpeners w ere also

not located w ithin accessible reach ranges. Carpet in

classroom 150 w as deteriorating and could create

trip hazards or hinder w heelchair travel as show n in

the f igure to the right.

SECOND FLOOR

Barriers noted above in public use spaces w ere similar to those identif ied in the low er f loors

of the building. Many staff and faculty off ices are located on f loor 2. Staff only areas w ere not part of the scope of w ork for this assessment report.

A w omen’s single accommodation toilet room is located on the w est side of f loor 2. No

drinking fountain w as located on f loor 2. The door signage w as not accessible, the entry

door w as too narrow for someone using a mobility assist device to enter and the entry door

w as heavy. The room could be remodeled to provide w heelchair access w ith the relocation

or replacement of dispensers, the toilet and lavatory. Fire pulls in the stairw ell and central

corridor w ere not f ist operable and the actuating devices including light sw itches w ere not located w ithin accessible reach ranges.

Corridors, a computer lab and the Precollege Program w orkroom w ere identif ied w ith

barriers described above including a lack of maneuvering clearance due to both the number of desks or w orkspaces in rooms and the limited square footage.

THIRD FLOOR

Restrooms or drinking fountains w ere not provided on the third f loor. A number of staff -use

only spaces and w ork areas w ere located on the f loor. Public areas on f loor 3 include

corridors, a north stairw ay, conference room and w aiting room for academic advising. The

entry doors and signage at the w aiting room and conference room w ere not accessible,

some controls and mechanisms w ere not at accessible locations and the table used for

meetings lacked accessible knee clearance and no portable assistive listening system w as identif ied as available for use in the room, on an as needed basis.

A w orkroom w as located on the east side of the f loor. The space w as not provided w ith

accessible f ixtures, counter, sink or maneuvering clearance but the room also served as an

emergency exit by w ay of stairs w here no accessible route w as provided for people w ith

mobility impairments and no accessible bridge connection w as provided on floor 3 w hich prevents access to the f loor for people w ith mobility impairments.

The follow ing barrier data records provide more detailed information on the barriers

described above.

Page 10: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

EXTERIOR AREA BARRIERS

Page 11: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance

Barrier #: 255A

X Coordinate: 7478982.85

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign with arrow directing people to accessible entrance

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340709.422

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance

Barrier #: 255B

X Coordinate: 7478982.85

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Bottom

Barrier  Description:

Bottom handrail extension not sloped for length of one tread beyond the last riser nosing

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

Bottom handrail extension not min. 12"

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.3

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340709.422

Performance Standard: No

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 7

Page 12: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance

Barrier #: 255C

X Coordinate: 7478982.85

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of exterior stairway

Rec. Solution: Consider providing contrasting color on each tread

              Findings:

No contrasting color provided

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 35

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340709.422

Performance Standard: Yes

Reference Dwg: 1 of 5

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance

Barrier #: 255D

X Coordinate: 7478982.85

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Lift

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Provide ISA directional sign indicating location of and route to accessible entry at Covell Hall

              Findings:

Stairway is the only pedestrian route into building

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 0

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340709.422

Performance Standard: No

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 8

Page 13: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance Landing

Barrier #: 257A

X Coordinate: 7478986.92

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign with arrow directing people to accessible entrance

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340704.456

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  6/28/2011 Report Date 6/28/2011

Location: Exterior ‐ North Stairway Entrance Landing

Barrier #: 257B

X Coordinate: 7478986.92

Barrier Area: Doors or Gates

Barrier Type: Door/Gate Landing ‐ Existing (≥ 5.0%)

Barrier  Description:

Door or gate lacks landing on both sides of door

Rec. Solution: Demolish and reconstruct level landing

              Findings:

9.5% slope

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340704.456

Performance Standard: No

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 9

Page 14: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance

Barrier #: 498A

X Coordinate: 7478982.473

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign indicating location of and route to accessible entry at Covell Hall

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340625.542

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance

Barrier #: 498B

X Coordinate: 7478982.473

Barrier Area: Stairways

Barrier Type: Riser Height ‐ Existing

Barrier  Description:

Stair riser height or tread width is not consistent

Rec. Solution: Demolish and construct new stairway

              Findings:

Consistent stair riser height or tread width provided

Quantity: SF

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 250

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340625.542

Performance Standard: No

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 10

Page 15: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance

Barrier #: 498C

X Coordinate: 7478982.473

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

32" handrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340625.542

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance

Barrier #: 498D

X Coordinate: 7478982.473

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of exterior stairway

Rec. Solution: Consider providing contrasting color on each tread

              Findings:

No contrasting color provided

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 35

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340625.542

Performance Standard: Yes

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 11

Page 16: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance

Barrier #: 498E

X Coordinate: 7478982.473

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Lift

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Provide a wheelchair lift to reach upper floors in at least one location

              Findings:

Stairway is the only pedestrian route into building

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 0

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340625.542

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance Landing

Barrier #: 499A

X Coordinate: 7478997.92

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign with arrow directing people to accessible entrance

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340636.491

Performance Standard: No

Reference Dwg: 1 of 5

ADA Assessment and Survey 2014 12

Page 17: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  7/7/2011 Report Date 7/7/2011

Location: Exterior ‐ South Stairway Entrance Landing

Barrier #: 499B

X Coordinate: 7478997.92

Barrier Area: Doors or Gates

Barrier Type: Door/Gate Landing ‐ Existing (≥ 5.0%)

Barrier  Description:

Door or gate lacks landing on both sides of door

Rec. Solution: Demolish and reconstruct level landing

              Findings:

9.8% slope

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: 340636.491

Performance Standard: No

Reference Dwg: 1 of 5

Field Date:  7/7/2011 Report Date 7/7/2011

Location:

Barrier #:

X Coordinate:

Barrier Area:

Barrier Type:

Barrier  Description:

Rec. Solution:

              Findings:

Quantity:

Notes: Barrier data record left blank intentionally to facilitate printing

Barrier Severity: Cost Est

Implementation Date:

Status:

Implementation Phase:

Code References:

As‐built :

Facility Function:

Implementation Priority:

Bldg Name: Batcheller Hall

Y Coordinate:

Performance Standard:

Reference Dwg:

ADA Assessment and Survey 2014 13

Page 18: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

INTERIOR AREA BARRIERS

Page 19: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ East Corridor H0002

Barrier #: 1A

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Abrupt Change in Level

Barrier  Description:

Change in level greater than 1/2" leading in circulation path

Rec. Solution: Repair or replace to remove trip hazard

              Findings:

Grate in route is deteriorating and may potential cause a trip hazard in circulation route

Quantity: LF

Notes: Accessible entry to Batcheller Hall is currently provided through Covell Hall's accessible entry

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 303.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ East Corridor H0002

Barrier #: 1B

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Permanent Room/Space

Barrier  Description:

No sign with raised characters and Braille at permanent room or space with visual sign

Rec. Solution: Provide sign at latch side of entry door, where possible

              Findings:

No tactile info on signs with visual information

Quantity: EACH

Notes: Room 0042 Non‐class laboratory

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 14

Page 20: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ East Corridor H0002

Barrier #: 1C

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Fire extinguisher protrudes 5" at 27‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ East Corridor H0002

Barrier #: 1D

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Horn/Strobe Device

Barrier  Description:

No horn or strobe in corridor where fire alarm exists in building

Rec. Solution: Provide horn/strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 15

Page 21: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: Room 0042A

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other

              Findings:

15 lbf

Quantity: EACH

Notes: One entry door to room 0042 is blocked by a shelving unit on the interior side and cannot be used

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 16

Page 22: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other

              Findings:

Door does not stop 5" from door frame

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 57‐1/2" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 17

Page 23: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/pull 18" SEC ‐ Blocked

Barrier  Description:

Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side

Rec. Solution: Provide automatic door opening device and remove stored item

              Findings:

17" strike edge clearance

Quantity: ADMINI

Notes: Blocked by trash can and desk. 4" to trash can and 17" to desk

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

Switches in room 49‐1/2" ‐ 57" high

Quantity: EACH

Notes: 2 light switches

Barrier Severity: 3 Hindrance Cost Est $1,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 18

Page 24: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide accessible desk or workstation

              Findings:

24‐3/4" high knee clearance

Quantity: EACH

Notes: 6 desks. None are accessible

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2H

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

37" high and 37" deep

Quantity: EACH

Notes: 3 outlets. Alternate outlets are located on the ground under the desk (power strips)

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 19

Page 25: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2I

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2J

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator or Control ‐ Height

Barrier  Description:

Control or mechanism not at max. 48" high for side reach

Rec. Solution: Relocate within accessible reach range

              Findings:

Desks block refrigerator and microwave clear floor space

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 20

Page 26: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2K

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator or Control ‐ Operation

Barrier  Description:

Control or mechanism not usable with a closed fist

Rec. Solution: Replace operating control

              Findings:

Ventilator dial not fist operable

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2L

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Object does not appear to be in circulation route. If desk is moved, provide detectable warning

              Findings:

Fire alarm/electrical panel protrudes 6" at 59" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 21

Page 27: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Grad Student Lab 0042A

Barrier #: 2M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: 2 entry doors

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 22

Page 28: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other

              Findings:

8 ‐ 11 lbf

Quantity: EACH

Notes: Single door and double door entry from corridor

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other

              Findings:

3 ‐ 4 second sweep

Quantity: EACH

Notes: Single door and double door entry from corridor

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 23

Page 29: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: Single door and double door entry from corridor. Door hardware accessible at single entry door, but not at double doors

Barrier Severity: 3 Hindrance Cost Est $6,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 3

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3E

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Side Reach Obstructed (≤10")

Barrier  Description:

Light switch control box top edge over an obstruction max. 34" high located above 48"

Rec. Solution: Relocate control or mechanism to max. 48" high

              Findings:

50‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 24

Page 30: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3F

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Electrical panel protrudes 7" at 54‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

A/C unit 66" high

Quantity: EACH

Notes: Blocked by desks

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 25

Page 31: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide at least 2 accessible desks

              Findings:

At least 2 accessible desks not provided

Quantity: EACH

Notes: 26 computer workstations. None are accessible

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. one accessible desk or workstation

              Findings:

14" knee clearance at computer stations

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 26

Page 32: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 0041

Barrier #: 3J

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ West Corridor H0003

Barrier #: 4A

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Tactile Exit Sign at Door

Barrier  Description:

Ground floor doors that exit directly to the exterior lacks tactile exit sign

Rec. Solution: Provide new sign stating “EXIT” at exiting side of door

              Findings:

Accessible sign not provided

Quantity: EACH

Notes: Fire Extinguisher is not a protruding object in this corridor

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 27

Page 33: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ West Corridor H0003

Barrier #: 4B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

Electrical switch above 48" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ West Corridor H0003

Barrier #: 4C

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pull has no usable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 28

Page 34: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ West Corridor H0003

Barrier #: 4D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

64" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ West Corridor H0003

Barrier #: 4E

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 29

Page 35: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 45 and 45A

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other

              Findings:

Door closers provided but disconnected. Force to operate exceed 5 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 30

Page 36: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes: Double door between 041 and 045

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: At both entry doors and door between 041 and 045. Measured at 57" high

Barrier Severity: 3 Hindrance Cost Est $4,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 31

Page 37: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/push 12" SEC

Barrier  Description:

Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other or remode

              Findings:

5‐1/2" strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 32

Page 38: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

A/C controls 65" high and obstructed by workstations

Quantity: EACH

Notes: 2 units

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide at least 2 accessible desks

              Findings:

At least 2 accessible desks not provided

Quantity: EACH

Notes: 28 workstations. None are accessible

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 33

Page 39: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5I

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide accessible desk or workstation

              Findings:

16‐3/4" deep knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Computer Room 45

Barrier #: 5J

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 34

Page 40: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on overhead sign not large enough to view from a distance

Quantity: EACH

Notes: 1‐1/2" high

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 35

Page 41: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

Door does not stop 5" from door frame

Quantity: EACH

Notes: 5 second sweep

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 36

Page 42: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser protrudes 10" at 59" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 37

Page 43: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers

Barrier  Description:

Dispenser operating mechanism not operable with a fist or less than 5 lbf

Rec. Solution: Replace dispenser

              Findings:

Paper towel dispensing mechanism does not function

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

Paper towel dispenser 59" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 38

Page 44: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Cl

Barrier  Description:

Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge

Rec. Solution: Replace lavatory

              Findings:

23" high

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

45" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 39

Page 45: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Flush Controls

Barrier  Description:

Urinal flush controls involve more than 5 lbf (22.2 N) to activate

Rec. Solution: Replace urinal controls where possible or entire urinal

              Findings:

6 lbf. Lavatory and stall block urinal clear floor space

Quantity: JOB

Notes: 33" deep clear floor space. No clear floor space for people using wheelchairs

Barrier Severity: 2 Recommended Cost Est $800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Flush Controls

Barrier  Description:

Urinal flush controls mounted higher than 48" above the floor

Rec. Solution: Replace urinal controls where possible or entire urinal

              Findings:

51" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 40

Page 46: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Rim

Barrier  Description:

Min. 1 urinal has no elongated rim projecting 14" to 17" from wall

Rec. Solution: Replace urinal

              Findings:

13" projection from wall

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 605.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Rim

Barrier  Description:

Urinal not max. 17" above the floor

Rec. Solution: Replace urinal

              Findings:

24" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 605.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 41

Page 47: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Maneuvering Clearance

Barrier  Description:

No 60" turning circle provided in toilet facility (min. 27" high above floor)

Rec. Solution: Remodel toilet room

              Findings:

45" between toilet stall door to lavatories

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $80,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.2.1

As‐built : 140

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Headroom

Barrier  Description:

Door clearance not min. 80" high

Rec. Solution: Remodel room to provide access

              Findings:

74‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 42

Page 48: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Transfer ‐ Floor‐mounted

Barrier  Description:

Min. 60" wide x 59" deep clear floor space not provided at floor‐mounted fixture

Rec. Solution: Remodel to provide front transfer space

              Findings:

34" wide x 54‐1/2" deep

Quantity: SF

Notes: 4 stalls with the same dimensions

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6R

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook

              Findings:

67‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 43

Page 49: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6S

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Grab Bars

Barrier  Description:

No grab bars provided at water closet

Rec. Solution: Provide side and rear grab bars with reinforcement

              Findings:

No grab bars provided

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $900.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6T

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Seat Height

Barrier  Description:

Water closet seat not between 17" to 19" high

Rec. Solution: Replace water closet

              Findings:

16" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $850.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 44

Page 50: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6U

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Parallel Approach

Barrier  Description:

Where the high side reach is over an obstruction, the height of the obstruction exceeds 34" maximum

Rec. Solution: Relocate dispenser to location within reach range or provide additional dispenser

              Findings:

54 " ‐ 60" high. Water closet blocks seat cover dispenser clear floor space

Quantity: JOB

Notes: 54 " ‐ 60" high. Water closet blocks seat cover dispenser clear floor space

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6V

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Shelves

Barrier  Description:

Shelf provided not mounted between 40" and 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height

              Findings:

Shelf or cabinet not accessible

Quantity: EACH

Notes: Four shelves in water closets at 66" high

Barrier Severity: 2 Recommended Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 45

Page 51: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Men's Restroom 0052

Barrier #: 6W

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 46

Page 52: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device at main entry and ISA directional sign at other door

              Findings:

16 lbf

Quantity: EACH

Notes: Sweep period okay

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 57‐1/2" high and covered by paper

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 47

Page 53: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height 1/2" with Ramp

Barrier  Description:

Door/Gate threshold bevel at max 1/2" lip exceeds 1:2 or 50% slope

Rec. Solution: Provide accessible threshold leading to new level landing at door

              Findings:

3/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/pull 18" SEC ‐ Blocked

Barrier  Description:

Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side

Rec. Solution: Remove trash bin

              Findings:

2" strike edge clearance

Quantity: ADMINI

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 48

Page 54: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

48‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Coat Hook ‐ Height

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

70" high. Desk and stored items block coat hook clear floor space

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 49

Page 55: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7H

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Chalkboard/Whiteboard ‐ Area of Use

Barrier  Description:

Bottom edge of writing surface not max. 38" high

Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people

              Findings:

Lower edge of writing surface 44" high from floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $1,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 904.3.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Projector Screen Pull

Barrier  Description:

Screen pull not at max. 48" high for side reach

Rec. Solution: Relocate to max. 48" high or provide extension

              Findings:

Projector screen pull 82” high. Table blocks whiteboard and projector screen clear floor space

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 50

Page 56: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Rearrange furniture to provide access

              Findings:

Passageway less than 36" in multiple locations around group table

Quantity: JOB

Notes: Circulation route around table

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7K

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table

              Findings:

25‐1/2" high knee clearance

Quantity: EACH

Notes: 4 tables placed together with 9 seats. Knee clearance not accessible

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 51

Page 57: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7L

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide accessible desk or workstation

              Findings:

24" ‐ 24‐1/2" high knee clearance

Quantity: EACH

Notes: 6 PC workstations and one work bench. None are accessible

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7M

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Rearrange furniture to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: JOB

Notes: 28" wide circulation route to flight simulator

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 52

Page 58: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7N

X Coordinate: N/A

Barrier Area: Turning Space

Barrier Type: Circular Turning Space ‐ Min. 60"

Barrier  Description:

Circular turning space not minimum of 60" in diameter (including toe/knee space)

Rec. Solution: Remodel to provide access

              Findings:

60" turning diameter not provided at flight simulator

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $6,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 304.3.1

As‐built : 80

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7O

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 53

Page 59: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7P

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7Q

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware. Door may be used in the case of an emergency to exit lab

              Findings:

Hardware not accessible

Quantity: EACH

Notes: Door to lobby L0001

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 54

Page 60: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Human Factors/Ergonomics Lab 50

Barrier #: 7R

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Recessed Door ‐ Push Side

Barrier  Description:

Door recessed by more than 8" lacks at least 12" clearance at push side of door

Rec. Solution: Provide automatic door opening device at main entry and ISA directional sign at other door

              Findings:

Recessed 9" and no strike edge clearance

Quantity: EACH

Notes: Door to lobby L0001

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: No sign identifying space L0001

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 55

Page 61: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

13 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 56

Page 62: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8D

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

58‐1/2" high. Stairs block electrical switch clear floor space

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8E

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Piping protrudes 6" at 43 1/2" high and electrical box creates protruding hazard

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 57

Page 63: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

59‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8G

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Lobby Info Sign

Barrier  Description:

No lobby informational sign with location of accessible elements

Rec. Solution: Provide lobby informational sign

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 58

Page 64: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Lobby L0001

Barrier #: 8I

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Elevator

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Provide a passenger elevator to reach upper floors

              Findings:

Stairway in lobby does not provide an accessible route through building

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $1,250,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 59

Page 65: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Stairway S0002

Barrier #: 9A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide accessible sign

              Findings:

No sign provided

Quantity: EACH

Notes: Stairway is not enclosed. Recommended: provide accessible tactile stairway signage to indicate discharge level.

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Stairway S0002

Barrier #: 9B

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Grip

Barrier  Description:

Handrail grip is not 1‐1/4" ‐ 2" in diameter

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

3‐1/4" inner handrail grip diameter

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $7,650.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.7

As‐built : 34

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 60

Page 66: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Stairway S0002

Barrier #: 9C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Bottom

Barrier  Description:

Bottom handrail extension not sloped for length of one tread beyond the last riser nosing

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No extensions on either side

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.3

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Stairway S0002

Barrier #: 9D

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $840.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 24

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 61

Page 67: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Stairway S0002

Barrier #: 9E

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Surface Condition ‐ Existing

Barrier  Description:

Stairway surface is not slip resistant

Rec. Solution: Provide slip resistant surface

              Findings:

Slip resistant surface could not be verified

Quantity: SF

Notes:

Barrier Severity: 4 Low Severity Cost Est $60,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.4

As‐built : 240

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Double doors 46, 046

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 62

Page 68: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: Double doors view panel located higher than 43" above the floor

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 63

Page 69: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10D

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes: Double doors view panel located higher than 43" above the floor

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door 10" Bottom Surface ‐ Kickplate

Barrier  Description:

Door/Gate lacks min. 10" smooth uninterrupted bottom surface

Rec. Solution: Provide kick plate at push side of door and remove door stop

              Findings:

Bottom of door not smooth and uninterrupted

Quantity: EACH

Notes: The bevel is at 8" and door stops are present on both doors

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.10

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 64

Page 70: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10F

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Shelving protrudes 9" at 48" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10G

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Piping across doorway protrudes at 78" high for 89" long

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 65

Page 71: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Piping protrudes 15" at 68" high. Multiple instances where the piping protrudes into path of travel

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10I

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ To Exit Door

Barrier  Description:

Exit door leading directly to an door to the exterior lacks tactile exit sign

Rec. Solution: Provide sign stating “TO EXIT” at exit side of door leading to an exit passage with a door to the 

              Findings:

Exit door leading to a door to the exterior lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 66

Page 72: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10J

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Running Slope ‐ Existing (8.34% ‐ 8.5%)

Barrier  Description:

Running slope exceeds 8.33% (8.34% to 8.5%)

Rec. Solution: Demolish existing and construct new ramp

              Findings:

8.5% running slope

Quantity: LF

Notes: Floor slopes towards the exit.

Barrier Severity: 4 Low Severity Cost Est $4,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 405.3

As‐built : 20

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10K

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Doormat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 67

Page 73: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10L

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Exterior Adjustment

Barrier  Description:

Door opening force exceeds 8.5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

17 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10M

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace or adjust existing closer

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 68

Page 74: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10N

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Door, sliding/folding door or gate clear width is not min. 32"

Rec. Solution: Replace door or gate and frame to provide min. one accessible door leaf

              Findings:

28" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10O

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Smooth Surface at Bottom

Barrier  Description:

Door/Gate lacks min. 10" smooth uninterrupted bottom surface

Rec. Solution: Change door hardware to provide smooth, uninterrupted surface

              Findings:

Door hardware prevents 10" smooth uninterrupted surface

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.10

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

ADA Assessment and Survey 2014 69

Page 75: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Basement ‐ Entry V0002

Barrier #: 10P

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible on exterior side

Quantity: EACH

Notes: Simultaneous thumb activation needed while pulling

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Entry V0102

Barrier #: 11A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign in location where people approaching building can make use of info

              Findings:

Sign located at top of stairs at entry door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 70

Page 76: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Entry V0102

Barrier #: 11B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Exterior Adjustment

Barrier  Description:

Door opening force exceeds 8.5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

14 lbf

Quantity: EACH

Notes: Sweep period okay

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Entry V0102

Barrier #: 11C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Doormat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 71

Page 77: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Entry V0102

Barrier #: 11D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pull has no usable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Entry V0102

Barrier #: 11E

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

63‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 72

Page 78: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on sign not large enough to view from a distance at 1‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 73

Page 79: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ Non‐Accessible Restroom

Barrier  Description:

No directional ISA sign identifying location of accessible restroom where all are not accessible

Rec. Solution: Provide ISA directional sign indicating location of and route to accessible restroom

              Findings:

No directional ISA sign provided to an accessible restroom

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Closer

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

6 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 74

Page 80: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Closer ‐ Sweep

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace or adjust existing closer

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Hardware

Barrier  Description:

Operating controls involve tight grasping, pinching or twisting

Rec. Solution: Replace hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 75

Page 81: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clearance ‐ Pull Side

Barrier  Description:

Door lacks min. 18" strike edge clearance at pull side

Rec. Solution: Relocate door or gate to provide maneuvering clearance

              Findings:

5" strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clearance ‐ Push Side

Barrier  Description:

Door lacks min. 12" strike edge clearance at push side

Rec. Solution: Relocate door or gate to provide maneuvering clearance

              Findings:

6" strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 76

Page 82: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

31" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Maneuvering Clearance

Barrier  Description:

Entry door encroaches into min. 60" turning space by more than 12"

Rec. Solution: Remodel toilet room

              Findings:

Dimensions of bathroom are 41‐3/4" wide x 71‐1/2" long, wall to wall

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $575.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 77

Page 83: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Electrical Switches

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

59‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 205.1 & 309.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser protrudes 10" at 59" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 78

Page 84: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

Paper towel dispenser 53" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Dispenser protrudes 6‐1/4" at 54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 79

Page 85: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

Dispenser 66" high. Toilet, sink and wall block dispensers clear floor space

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Centerline

Barrier  Description:

Lavatory adjacent to wall not min. 15" to the centerline of fixture

Rec. Solution: Relocate or replace lavatory

              Findings:

12" centerline at lavatory in corner

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 80

Page 86: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Depth

Barrier  Description:

Lavatory lacks min. 17" in horizontal depth measured from back wall

Rec. Solution: Replace lavatory

              Findings:

10‐1/2" deep

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12R

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided. Radiator, trash can and walls block sink clear floor space

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 81

Page 87: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12S

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

55‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12T

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Shelves

Barrier  Description:

Shelf provided not mounted between 40" and 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height

              Findings:

Shelf or cabinet not accessible

Quantity: EACH

Notes: 65‐1/4" high

Barrier Severity: 2 Recommended Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 82

Page 88: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12U

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Grab Bars

Barrier  Description:

No grab bars provided at water closet

Rec. Solution: Provide side and rear grab bars with reinforcement

              Findings:

No grab bars provided

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $900.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12V

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Seat Height

Barrier  Description:

Water closet seat not between 17" to 19" high

Rec. Solution: Replace water closet

              Findings:

15" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $850.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 83

Page 89: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12W

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Centerline

Barrier  Description:

Water closet centerline not between 16" and 18" O. C.

Rec. Solution: Relocate water closet

              Findings:

21‐3/4" OC

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12X

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Parallel Approach

Barrier  Description:

Where the high side reach is over an obstruction, the height of the obstruction exceeds 34" maximum

Rec. Solution: Relocate dispenser to location within reach range or provide additional dispenser

              Findings:

Seat cover dispenser 52" high. Water closet blocks dispenser clear floor space

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 84

Page 90: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12Y

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

71‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women's Restroom 0146

Barrier #: 12Z

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 85

Page 91: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Egress Stairway ‐ Clear Width

Barrier  Description:

Exit stairway does not provide min. 48" clear width between handrails

Rec. Solution: Reconfigure handrail to provide min. 48" clear width

              Findings:

36‐1/4" clear width between handrails

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Doormat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 86

Page 92: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Protruding Hazard

Barrier  Description:

Object protrudes more than 4" into pedestrian way

Rec. Solution: Remove object or provide detectable warning

              Findings:

Electrical panel protrudes 6‐1/2" at 35‐1/2" high

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in stairwell

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 87

Page 93: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13E

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide accessible sign

              Findings:

No sign provided

Quantity: EACH

Notes: Also, tactile stairway signage not provided to indicate stair level or discharge level

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Exit Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN” at latch side of each exit door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 88

Page 94: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13G

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

13 ‐ 16 lbf

Quantity: EACH

Notes: Sweep period okay

Barrier Severity: 1 Necessary Cost Est $900.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Replace hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 89

Page 95: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Stairway S0102

Barrier #: 13I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: At 54‐1/4" high

Barrier Severity: 3 Hindrance Cost Est $4,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Lobby Info Sign

Barrier  Description:

No lobby informational sign with location of accessible elements

Rec. Solution: Provide lobby informational sign

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 90

Page 96: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 147, 152

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14C

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pull has no usable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 91

Page 97: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

64‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14E

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

64‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 92

Page 98: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Telephone 56" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

5" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 93

Page 99: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14H

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Provide detectable warning (wing walls)

              Findings:

Shelf protrudes 12" at 35‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14I

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Alcove ‐ New Construction

Barrier  Description:

Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path

Rec. Solution: Construct new alcove as detectable warning

              Findings:

No alcove provided

Quantity: SF

Notes: Higher fountain protrudes 8" at 32‐1/2" and Lower fountain protrudes 8" at 27‐1/2"

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 20

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 94

Page 100: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14J

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Bubbler water flow

Barrier  Description:

Water flow from bubbler not min. 4" high

Rec. Solution: Adjust drinking fountain to provide min. 4" high water flow

              Findings:

2" ‐ 2‐1/2" high water flow from bubbler

Quantity: JOB

Notes: High and Low Fountains

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.6

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14K

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Knee Clearance

Barrier  Description:

Knee clearance under fountain not min. 27" high

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

26‐1/2" high knee clearance

Quantity: EACH

Notes: Low Fountains

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 95

Page 101: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Lobby L0102

Barrier #: 14L

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15A

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 96

Page 102: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15B

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

10 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15C

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 97

Page 103: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Hardware ‐ Operation

Barrier  Description:

Operating controls involve tight grasping, pinching or twisting

Rec. Solution: Replace hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15E

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Vision Lights

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 47‐3/4" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 98

Page 104: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Clearance ‐ Min. 12" at Push Side

Barrier  Description:

Door lacks min. 12" strike edge clearance at push side

Rec. Solution: Provide automatic door opening device

              Findings:

7‐3/4" strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

54" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 205.1 & 309.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 99

Page 105: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Pencil sharpener 54" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

13‐1/4" high

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 100

Page 106: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15J

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Abrupt Change in Level

Barrier  Description:

Change in level greater than 1/2" leading in circulation path

Rec. Solution: Repair to remove trip hazard

              Findings:

Carpet is deteriorating and may create a tripping hazard

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 303.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide at least 3 accessible desks

              Findings:

At least 3 accessible desks not provided

Quantity: EACH

Notes: 48 desks. 1 accessible desk provided

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 101

Page 107: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15L

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Rearrange furniture to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15M

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Integration

Barrier  Description:

Desk not integrated into assembly seating

Rec. Solution: Move desk to integrated setting

              Findings:

Desk identified as accessible is not integrated into typical seating

Quantity: EACH

Notes: Desk is accessible

Barrier Severity: 2 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 102

Page 108: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Projector Screen Pull

Barrier  Description:

Screen pull not at max. 48" high for side reach

Rec. Solution: Relocate to max. 48" high or provide extension

              Findings:

Projector screen pull 67‐1/2“ high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15O

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Telephones 49" high. Stored elements block telephone clear floor space

Quantity: EACH

Notes: 2 telephones

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 103

Page 109: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15P

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Podium  ‐ Surface Height

Barrier  Description:

Surface height exceeds 34" high

Rec. Solution: Provide min. 1 accessible  podium

              Findings:

Keyboard and monitor 35‐1/4" high ‐ 43" high at the workstation

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Classroom 0150

Barrier #: 15Q

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 104

Page 110: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 151, 151B, 151D, 151E

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 4

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on sign not large enough to view from a distance at 1/2" high

Quantity: EACH

Notes: "Undergraduate Programs"

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 105

Page 111: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 106

Page 112: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 54‐1/4" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 107

Page 113: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high

              Findings:

42‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Clear Floor Space ‐ Wheelchair Use

Barrier  Description:

Clear floor space of min. 30" by 48" not provided

Rec. Solution: Rearrange furniture to provide wheelchair space

              Findings:

No wheelchair space provided in waiting area

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 108

Page 114: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16I

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate within accessible reach range

              Findings:

Printer 54" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36"

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Remodel to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: LF

Notes: 34‐1/2" wide circulation between desk and wall

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 109

Page 115: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Undergraduate Programs Office 0151

Barrier #: 16K

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Door

Barrier  Description:

Ground floor doors that exit to exterior lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT” at exit side of door

              Findings:

Exit door with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 110

Page 116: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Dispenser 53" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17C

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

64‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 111

Page 117: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Doormat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Exterior Adjustment

Barrier  Description:

Door opening force exceeds 8.5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 112

Page 118: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Exterior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace or adjust existing closer

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ South Entry Vestibule V0102

Barrier #: 17G

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign in location where people approaching building can make use of info

              Findings:

Sign posted at top of stairway on view panel

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 113

Page 119: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18A

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

10 ‐ 13 lbf

Quantity: EACH

Notes: Double Doors

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

Door does not stop 5" from door frame

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 114

Page 120: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/4" without bevel

Barrier  Description:

Door/Gate threshold exceeds 1/4" in height without a bevel

Rec. Solution: Provide new door threshold

              Findings:

Threshold surface deteriorating, not firm and stable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18D

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 115

Page 121: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18E

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: Room 145

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18F

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on sign not large enough to view from a distance at 3/8" high

Quantity: EACH

Notes: Room 145

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 116

Page 122: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

58" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18H

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Mailbox ‐ High Reach Range

Barrier  Description:

Mailbox opening is above 48" high

Rec. Solution: Relocate to provide opening at max. 48" high

              Findings:

Mail slots 61‐1/2" ‐ 71" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 117

Page 123: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ East Corridor H0102

Barrier #: 18I

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in corridor

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: Directional sign to "The HUB room 0144"

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 118

Page 124: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Visual Information Provided (Exhibitions)

Barrier  Description:

Visual sign providing information for program, service or activity not accessible

Rec. Solution: Provide information in alternate format to provide access to people with vision impairments

              Findings:

Accessible sign not provided

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ADA Title II Technical Assistance Manual 3.2000 Denial of participation

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

13 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 119

Page 125: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Provide automatic door opening device

              Findings:

Door does not stop 5" from door frame

Quantity: EACH

Notes: 5 second sweep

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 47‐3/4" high and blocked by posters

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 120

Page 126: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐1/2" high

Quantity: EACH

Notes: Desks are pedestal base desks but they provide enough knee clearance at the visitor's side of the desk

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Protruding Object

Barrier  Description:

Wall mounted object (dispensers) protrudes more than 4" from wall

Rec. Solution: Relocate or remove object or provide detectable warning

              Findings:

Coat hook rack protrudes more than 4" at 64‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 121

Page 127: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Coat Hook ‐ Height

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

64‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19I

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Clear Floor Space ‐ Wheelchair Use

Barrier  Description:

Clear floor space of min. 30" by 48" not provided

Rec. Solution: Rearrange furniture to provide wheelchair space

              Findings:

No space provided for wheelchair users

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 122

Page 128: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19J

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table

              Findings:

12‐1/2" deep knee clearance. Cubicles are 37" wide from entrance to the wall

Quantity: EACH

Notes: 3 cubical study spaces

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Chalkboard/Whiteboard ‐ Area of Use

Barrier  Description:

Bottom edge of writing surface not max. 38" high

Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people

              Findings:

Lower edge of writing surface 40‐3/4" high from floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $1,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 904.3.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 123

Page 129: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19L

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table

              Findings:

12‐1/2" deep knee clearance

Quantity: EACH

Notes: 4 tables

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ The HUB 0144

Barrier #: 19M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 124

Page 130: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on sign not large enough to view from a distance at 3/8" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 125

Page 131: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: View panel is 47‐1/4" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 126

Page 132: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20E

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐1/2" ‐ 50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Coat Hook ‐ Height

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

56‐1/2" high. Bookcase blocks  clear floor space at coat hook and electrical switch

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 127

Page 133: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

12‐3/4" high. Stored items block outlet clear floor space

Quantity: EACH

Notes: Tables have accessible knee clearance

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36"

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Demolish existing and construct new passageway

              Findings:

12" ‐ 14‐1/4" wide circulation route to whiteboard, and advising desk

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 128

Page 134: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20I

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Desk ‐ Protruding Hazard

Barrier  Description:

Desk creates protruding hazard in accessible route

Rec. Solution: Provide detectable warning, as needed

              Findings:

Desk protrudes more than 4" above 27" high

Quantity: EACH

Notes: Desk does have accessible knee clearance

Barrier Severity: 2 Necessary Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Carpet/Rug

Barrier  Description:

Carpet/rug not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting carpet/rug or replace

              Findings:

Carpet/rug creates tripping hazard

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 129

Page 135: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20L

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Chalkboard/Whiteboard ‐ Area of Use

Barrier  Description:

Bottom edge of writing surface not max. 38" high

Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people

              Findings:

Lower edge of writing surface 49‐1/2" high from floor

Quantity: EACH

Notes: Whiteboard on door 49‐1/2" high

Barrier Severity: 3 Hindrance Cost Est $1,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 904.3.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 1 ‐ Women in Engineering Lounge 141

Barrier #: 20M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 5

ADA Assessment and Survey 2014 130

Page 136: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension

Barrier  Description:

Handrail extension does not return to wall, guard or landing surface

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

Electrical box blocks top handrail extension

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21B

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide accessible sign

              Findings:

No sign provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 131

Page 137: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Exit Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21D

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

14 lbf

Quantity: EACH

Notes: 2 entry doors both measured with the same force

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 132

Page 138: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21E

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Closer ‐ Interior Sweep ADA

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace or adjust existing closer

              Findings:

4 second sweep

Quantity: EACH

Notes: West stair door sweep is okay at 7 sec ‐ East stairway door 4 sec

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Replace hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 133

Page 139: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Stairway S0202

Barrier #: 21G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 241, 243, 253

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 134

Page 140: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22B

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Carpet ‐ Firmly Attached

Barrier  Description:

Carpet, carpet tile or exposed edges of carpet not securely attached or fastened to floor

Rec. Solution: Fasten carpet or tiles firmly to floor, remove or replace

              Findings:

Carpet not firmly attached to floor. Surface deteriorating, not firm and stable

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $2,400.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2

As‐built : 200

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22C

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 135

Page 141: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22D

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

12‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22E

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 136

Page 142: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22F

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pull has no usable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

58" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 137

Page 143: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Main Corridor H0202

Barrier #: 22H

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn provided with strobe

Rec. Solution: Provide horn device with strobe device

              Findings:

Horn provided without a strobe

Quantity: EACH

Notes: Door at the end of the hall leads to Dearborn ‐ Door barriers noted in Dearborn's Database

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23A

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 138

Page 144: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23B

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Clearance ‐ Min. 12" at Push Side

Barrier  Description:

Door lacks min. 12" strike edge clearance at push side

Rec. Solution: Relocate door or gate to provide maneuvering clearance

              Findings:

No strike edge clearance

Quantity: EACH

Notes: Blocked by trash cans

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23C

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 139

Page 145: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Projector Screen Pull

Barrier  Description:

Screen pull not at max. 48" high for side reach

Rec. Solution: Relocate to max. 48" high or provide extension

              Findings:

Projector screen pull 59‐1/2“ high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23E

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Workstation ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 27" high, 30" wide and 8" deep not provided

Rec. Solution: Reposition workstation to provide knee clearance

              Findings:

14‐1/2" deep knee clearance

Quantity: EACH

Notes: Instructors workstation

Barrier Severity: 1 Necessary Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 140

Page 146: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23F

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table

              Findings:

24‐1/2" high knee clearance

Quantity: EACH

Notes: Instructors table

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Telephone 53" high. Stored elements block telephone clear floor space

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 141

Page 147: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

10‐1/4" high

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide at least 3 accessible desks

              Findings:

At least 3 accessible desks not provided

Quantity: EACH

Notes: 49 desks. 1 desk identified as accessible

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 142

Page 148: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Rearrange furniture to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Integration

Barrier  Description:

Desk not integrated into assembly seating

Rec. Solution: Move accessible desk to integrated setting

              Findings:

Desk identified as accessible is not integrated into typical seating

Quantity: EACH

Notes:

Barrier Severity: 2 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 143

Page 149: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23L

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk

Rec. Solution: Reposition desk to provide knee clearance

              Findings:

26‐1/4" high, 16‐1/4" deep knee clearance

Quantity: EACH

Notes: Adjustable Desk

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23M

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 144

Page 150: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Classroom 0250

Barrier #: 23N

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in classroom

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0205

Barrier #: 24A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 255, 257, 261

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 145

Page 151: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0205

Barrier #: 24B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0205

Barrier #: 24C

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanisms to min. 15" or max. 48" high

              Findings:

Pamphlet holder 50‐1/2" ‐ 75‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 146

Page 152: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

16 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 147

Page 153: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Provide automatic door opening device

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Door, sliding/folding door or gate clear width is not min. 32"

Rec. Solution: Replace door or gate and frame

              Findings:

28‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 148

Page 154: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/pull 18" SEC ‐ Relocate Door

Barrier  Description:

Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side

Rec. Solution: Provide automatic door opening device

              Findings:

4" strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 149

Page 155: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Protruding Object

Barrier  Description:

Wall mounted object (dispensers) protrudes more than 4" from wall

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser protrudes 10" at 55" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Height

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

Paper towel dispenser 55" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 150

Page 156: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25I

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

57‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

41‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 151

Page 157: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Cl

Barrier  Description:

Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge

Rec. Solution: Replace lavatory

              Findings:

24" high knee clearance

Quantity: JOB

Notes: Only lavatory

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 152

Page 158: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

68‐1/2" high. Wall blocks coat hook clear floor space

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Transfer ‐ Floor‐mounted

Barrier  Description:

Min. 60" wide x 59" deep clear floor space not provided at floor‐mounted fixture

Rec. Solution: Remodel to provide front transfer space

              Findings:

53‐3/4" wide to lavatory

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.1

As‐built : 80

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 153

Page 159: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Grab Bars

Barrier  Description:

No grab bars provided at water closet

Rec. Solution: Provide side and rear grab bars with reinforcement

              Findings:

No grab bars provided

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $900.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Flush Handle

Barrier  Description:

Handle does not point to wide side of stall or compartment

Rec. Solution: Replace water closet

              Findings:

Handle positioned on wall side

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $850.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.6

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 154

Page 160: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Seat Height

Barrier  Description:

Water closet seat not between 17" to 19" high

Rec. Solution: Replace water closet

              Findings:

15‐1/2" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25R

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Centerline

Barrier  Description:

Water closet centerline not between 16" and 18" O. C.

Rec. Solution: Relocate water closet

              Findings:

19‐1/2" OC

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 155

Page 161: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25S

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser not within 7" to 9" from front edge of toilet

Rec. Solution: Reposition or replace toilet paper dispenser

              Findings:

Mounted behind front of toilet

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25T

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers

Barrier  Description:

Dispenser not located on an accessible route

Rec. Solution: Replace or remount dispenser

              Findings:

Sanitary product dispenser located behind toilet seat rim

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 156

Page 162: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25U

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Women's Restroom 0259

Barrier #: 25V

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 157

Page 163: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Central Corridor H0204

Barrier #: 26A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: Room 251

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Central Corridor H0204

Barrier #: 26B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 158

Page 164: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

17 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 159

Page 165: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 160

Page 166: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: 48‐1/2" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/pull 18" SEC ‐ Blocked

Barrier  Description:

Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side

Rec. Solution: Provide automatic door opening device and move table/items to provide access

              Findings:

4‐1/4" strike edge clearance

Quantity: ADMINI

Notes: Blocked by table

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 161

Page 167: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route through corridor not min. 36"

Rec. Solution: Rearrange or remove equipment/furniture to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: JOB

Notes: 26" wide circulation route between table and copier

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 162

Page 168: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27I

X Coordinate: N/A

Barrier Area: Turning Space

Barrier Type: Circular Turning Space ‐ Min. 60"

Barrier  Description:

Circular turning space not minimum of 60" in diameter (including toe/knee space)

Rec. Solution: Rework floor or ground surface

              Findings:

60" turning diameter not provided in room

Quantity: SF

Notes: AC unit, boxes under table and copier encroach into  turning circle

Barrier Severity: 2 Recommended Cost Est $3,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 304.3.1

As‐built : 40

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27J

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

12‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 163

Page 169: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27K

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Move stored objects

              Findings:

No knee clearance at work desk

Quantity: EACH

Notes: Paper boxes, vacuum, AC unit block knee clearance under large desk

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27L

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate within accessible reach range

              Findings:

Printer 50‐1/2" high

Quantity: EACH

Notes: Room orientation blocks table, shelves, printer, shredder, copier, microwave clear floor space

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 164

Page 170: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Precollege Programs Workroom 249

Barrier #: 27M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0203

Barrier #: 28A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 245, 247

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 165

Page 171: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0203

Barrier #: 28B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ West Corridor H0203

Barrier #: 28C

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Pamphlet holder 51‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 166

Page 172: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: Lab 0244

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29B

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 167

Page 173: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29C

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Closer ‐ Sweep

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Threshold (Replace)

Barrier  Description:

Door/Gate threshold height exceeds 1/2"

Rec. Solution: Provide new door threshold

              Findings:

3/4" high. Threshold not firm and stable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 168

Page 174: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29E

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Clearance ‐ Min. 60" Perpendicular

Barrier  Description:

Door lacks min. 60" perpendicular to door swing at pull side

Rec. Solution: Provide automatic door opening device

              Findings:

Desk and stored items block clear space perpendicular to door

Quantity: EACH

Notes: Remove stored items to provide clearance

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

54‐3/4" high. Stored elements block electrical switch clear floor space

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 169

Page 175: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk

Rec. Solution: Reposition desk to provide knee clearance

              Findings:

25‐1/2" knee clearance. Wall blocks instructors desk clear floor space

Quantity: EACH

Notes: Instructors desk

Barrier Severity: 1 Necessary Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Television protrudes 6" at 54" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 170

Page 176: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Projector Screen Pull

Barrier  Description:

Screen pull not at max. 48" high for side reach

Rec. Solution: Relocate to max. 48" high or provide extension

              Findings:

Projector screen pull 101“ high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36"

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Remodel to provide access

              Findings:

Passageway less than 36" in multiple locations

Quantity: LF

Notes: 19‐1/2" wide circulation route. There are multiple occurrence throughout this room

Barrier Severity: 1 Necessary Cost Est $12,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 100

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 171

Page 177: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate within accessible reach range

              Findings:

Printer 56‐3/4 " high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29L

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide min. 2 accessible desks

              Findings:

Min. 1 accessible desk not provided

Quantity: EACH

Notes: 24 computer workstations. None are accessible

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 172

Page 178: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29M

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk

Rec. Solution: Provide min. 2 accessible desks

              Findings:

25‐1/2" high knee clearance

Quantity: EACH

Notes: 24 computer workstations. None are accessible

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 2 ‐ Computer Graphics Education Lab 244

Barrier #: 29N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 5

ADA Assessment and Survey 2014 173

Page 179: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Protruding Hazard

Barrier  Description:

Protruding object in route of travel between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning

              Findings:

Electrical box has sharp edges at the top of the handrail

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30B

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide accessible sign

              Findings:

No sign provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 174

Page 180: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Exit Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30D

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing closer

              Findings:

14 lbf

Quantity: EACH

Notes: 2 entry doors both with the same force

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 175

Page 181: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30E

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Closer ‐ Interior Sweep ADA

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace closer or provide automatic door opener

              Findings:

3 second sweep

Quantity: EACH

Notes: 2 entry doors

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Door Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Replace hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 176

Page 182: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Stairway S0302

Barrier #: 30G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Main Entry and rooms 350C, 350B, 350A within waiting area

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 4

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 177

Page 183: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

19 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Provide automatic door opening device

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 178

Page 184: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door 10" Bottom Surface ‐ Door Stop

Barrier  Description:

Door stop interrupts min. 10" smooth bottom surface

Rec. Solution: Remove door stop or other element at bottom of door at push side

              Findings:

Door stop at bottom of door can create trapping condition

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.10

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31E

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 179

Page 185: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Coat Hook ‐ Height

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

65‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Waiting Room L0350

Barrier #: 31G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in corridor

Rec. Solution: Provide strobes in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 180

Page 186: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs

              Findings:

No tactile signage provided at doors within public route

Quantity: EACH

Notes: Rooms 352, 349, 345, 344

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 4

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32B

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Pedestal Base

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Pedestal base at table blocks knee clearance

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.2.2 and 306.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 181

Page 187: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32C

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Fire riser protrudes 8" at 57‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32D

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Electrical box protrudes 6‐1/4" at 48" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 182

Page 188: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32F

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Viewing From Distance ‐ >70” high

Barrier  Description:

Signs between 70" and 120" high lack characters at least 2" high

Rec. Solution: Replace sign with characters min. 2" in height for viewing at a distance

              Findings:

Characters on sign not large enough to view from a distance at 3/4" high

Quantity: EACH

Notes: Room 344 ‐‐ Not a protrusion

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.5.5 and Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pull has no usable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 183

Page 189: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32H

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

66‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Corridor H0301

Barrier #: 32I

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe

Barrier  Description:

No horn/strobes in corridor

Rec. Solution: Provide strobes in common use area

              Findings:

No strobe provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 184

Page 190: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes: This room also serves as an emergency exit by way of stairs

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33B

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Clear Floor Space ‐ 60" Turning Circle

Barrier  Description:

Clear floor space of min. 60" in diameter not provided where 360 degree turn is made

Rec. Solution: Remodel area to provide min. 60" turning space

              Findings:

Stairway blocks 60" turning circle

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $14,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 304.3.1

As‐built : 80

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 185

Page 191: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33C

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

14‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33D

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR UP” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 186

Page 192: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33E

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Both Sides

Barrier  Description:

No handrail provided at both sides of stairway

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No handrail provided at both sides

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $1,800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ADAAG 4.9.4* & 2010 ADAS 505.10.2

As‐built : 8

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Riser Height ‐ Existing

Barrier  Description:

Stair riser height is not between 4" and 7"

Rec. Solution: Demolish and construct new stairway

              Findings:

8‐1/2" stair riser height

Quantity: SF

Notes:

Barrier Severity: 4 Low Severity Cost Est $7,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 30

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 187

Page 193: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Tread Depth ‐ Existing

Barrier  Description:

Stair treads are not at least 11" in depth

Rec. Solution: Demolish and construct new stairway

              Findings:

10‐1/4" stair treads depth

Quantity: SF

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $280.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 8

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 188

Page 194: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33I

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Surface Condition ‐ Existing

Barrier  Description:

Stairway surface is not slip resistant

Rec. Solution: Demolish and construct new stairway

              Findings:

Slip resistant surface could not be verified

Quantity: SF

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33J

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Counter ‐ Surface

Barrier  Description:

Counter surface height exceeds 34" high

Rec. Solution: Replace or provide alternative accessible and integrated counter

              Findings:

36" high

Quantity: EACH

Notes: Stairway blocks sink and counter clear floor space

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 189

Page 195: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33K

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Replace counter. Flip‐up counters, adjacent tables and similar devices not permitted

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33L

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (≤10")

Barrier  Description:

Outlet located over an obstruction max. 34" high located above 48"

Rec. Solution: Relocate control or mechanism to max. 48" high

              Findings:

42‐1/2 " high over counter obstruction 24" deep

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 190

Page 196: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33M

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink Faucet ‐ Operation

Barrier  Description:

Faucets force to activate controls is greater than 5 pounds‐force lbf (22.2 N).

Rec. Solution: Replace faucet

              Findings:

15 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.4 & 309

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Depth

Barrier  Description:

Sink depth exceeds 6‐1/2" deep

Rec. Solution: Replace sink

              Findings:

7" deep

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 191

Page 197: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33O

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and 8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in room

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Workroom 342

Barrier #: 33P

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 192

Page 198: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

16 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 193

Page 199: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Hardware not accessible

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 194

Page 200: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes: At 48" high

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐3/4" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 195

Page 201: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34G

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36" (Stored Item)

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Rearrange furniture or replace to provide access to whiteboard, etc.

              Findings:

Passageway less than 36" in multiple locations

Quantity: JOB

Notes: 27" ‐ 35" wide circulation route around table

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34H

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table

              Findings:

26" high knee clearance. Walls block table and easel clear floor space

Quantity: EACH

Notes: 8 seats at table. None are accessible

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 196

Page 202: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

OSU ‐ BATCHELLER HALL

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34I

X Coordinate: N/A

Barrier Area: Assembly Areas

Barrier Type: Shared Assistive Listening System

Barrier  Description:

No shared assistive listening system for room with min. 10 seats

Rec. Solution: Provide shared ALS system

              Findings:

No device identified durning investigation

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 5

Field Date:  3/4/2014 Report Date 3/6/2014

Location: Floor 3 ‐ Conference Room 341

Barrier #: 34J

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Meeting Room

Barrier  Description:

No horn/strobes in meeting room

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Batcheller Hall

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 5

ADA Assessment and Survey 2014 197

Page 203: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

COST ESTIMATE SUMMARY

Page 204: 1 - Draft Cover - Batchellor Hall - Accessibility...1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points ADA Assessment & Survey Batcheller Hall 4 INTERIOR

SUMMARY REPORT

Cost Estimate Total $1,857,610.00

Cost Estimate ‐ Priority 1: $1,410,575.00

Cost Estimate ‐ Priority 2: $222,325.00

Cost Estimate ‐ Priority 3: $224,710.00

% of Total Cost Estimate: 75.93%

% of Total Cost Estimate: 11.97%

% of Total Cost Estimate: 12.10%

ADA Assessment and Survey 2014 198