1

HIGH CAPACITYPUBLIC SWITCH SYSTEM

- MAINTENANCE -

Page 2: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

2

PURPOSE

• Purpose of this presentation is to give idea about the maintenance and programming of DS200L system.

Page 3: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

3

TOPICS IN THIS PRESENTATION

• IP ADDRESS DEFINITION

• SOFTWARE LOADING- UPDATING

• USING SSH SECURE SHELL PROGRAM

• IDEA- DS200L SYSTEM CONNECTION

• IDEA-DCC CONNECTION

• OBTAINING LOG FILES

Page 4: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

4

IP ADDRESS DEFINITION

● DCC Utility Card

● PCU200 Block

● DS200 CC Card

● PPC SS7 Card

Page 5: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

5

• DS200L system realizes the communication through IP network in a local area. Thus, the system is isolated from the outer world. This structure is very important for the security of the system.

• DCC Utility Card, PCU200 Block, PPC SS7 Card and CC card are connected to the network switch exists in the DS200L system via a standard Ethernet cable. This fact must be considered while giving IP addresses to these modules and addresses that do not belong to this LAN must not be defined.

IP ADDRESS DEFINITION

Page 6: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

6

IP ADDRESS DEFINITION OF

DCC UTILITY CARD

Page 7: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

7

IP ADDRESS DEFINITION OF DCC UTILITY CARD

• Defining IP address to the DCC Utility card is done via Hyperterminal program on a maintenance computer.

• Maintenance computer, used for programming and maintaining the system, is connected to the same LAN with the DS200L system. It is a Windows O.S. based PC.

Page 8: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

8

• Connect DCC Utility card to the maintenance computer by a proper serial port cable.

• Before or after this connection, DCC Utility end or maintenance computer end of this cable should not be remained unconnected. In such a case, the cable is subject to external effects (like noise).

HYPERTERMINAL CONNECTION

Page 9: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

9

• Run Hyperterminal and select the proper port number.

HYPERTERMINAL CONNECTION

Page 10: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

10

● Bits per second 115200 ● Data Bits 0 ● Parity None ● Stop bits 1● Flow Control None

• Then, the settings in the figure below should be done.

HYPERTERMINAL CONNECTION

Page 11: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

11

• Run Hyperterminal and press ENTER button to see $ command prompt.

HYPERTERMINAL CONNECTION

Page 12: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

12

COMMANDS AT THE HYPERTERMINAL PROGRAM

• Type reboot in the $ command prompt. Then press ENTER key and press ESC key immediately to see dcc> prompt.

Page 13: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

13

• Enter the following commands in the given order, when dcc> prompt appears.

COMMANDS AT THE HYPERTERMINAL PROGRAM

a) dcc> printenv ipaddr The IP address of the DCC Utility card can be viewed by this command.

b) dcc> setenv ipaddr 192.168.2.186 A desired IP address is defined for the card by this command.

c) dcc> printenv ipaddrThe IP address of the DCC Utility card can be checked by this command.

d) dcc> saveenv The entire operations performed above are saved by this command

(Note: Write IP and MAC addresses of the DCC Utility card on a paperbefore following the procedure below.)

Page 14: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

14

• Commands below can be used for Server IP address and MAC address setting & viewing operations.

COMMANDS AT THE HYPERTERMINAL PROGRAM

(Note: ServerIP adress is the IP address of the server computer on which ktftp.exe runs. )

e) dcc> printenv serverip The IP address of the server computer, on which ktftp.exe runs is viewedby this command.

f) dcc> setenv serverip 192.168.2.66 The IP address of the server computer, on which ktftp.exe runs is changedby this command.

g) dcc> printenv serverip The IP address of the server computer, on which ktftp.exe runs is checkedby this command.

Page 15: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

15

h) dcc> printenv ethaddrThe MAC address that has been defined for the DCC Utility card is viewedby this command.

i) dcc> setenv ethaddr 00:08:d1:02:08:bd A MAC address is defined to the DCC Utility card by this command.

j) dcc> printenv ethaddrThe MAC address that has been defined for the DCC Utility card is checkedby this command.

IMPORTANT: MAC address definition operation should not be done without receiving the approval of the Karel experts

NOTE: IP and MAC addresses used above are given as an example.

COMMANDS AT THE HYPERTERMINAL PROGRAM

Page 16: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

16

• A screenshot regarding the commands above can be seen below.

COMMANDS AT THE HYPERTERMINAL PROGRAM

Page 17: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

17

IP ADDRESS DEFINITION OF

PCU200 BLOCK

Page 18: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

18

IP ADDRESS DEFINITION OF PCU200 BLOCK

• Run SSH Secure Shell program by entering the IP address of the PCU200 computer ( by default, IP addresses of PCU200 computers are written on its label sticker ) .

• After the connection is established, type comman yast and press ENTER key. Thus, YAST control screen is accessed.

NOTE: These operations also can be done without starting the system entering

the start command). Running the PCU200 computer will be enough.

Page 19: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

19

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 20: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

20

• Select Network Devices/ Network Card and press ENTER key.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 21: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

21

• Select Next and press ENTER key.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 22: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

22

• See the Ethernet devices that have been defined on the PCU200. Go to the relevant ethernet card and select Edit option using TAB key.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 23: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

23

• Set IP address at the IP address part properly, according to the network structure. Reach Next option by pressing the TAB key and press ENTER key.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 24: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

24

• Select Next option and press ENTER key.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 25: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

25

• See the IP address definition process as shown in the following window.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 26: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

26

• After the operation is completed, current IP address is changed. So, SSH Secure Shell connection will be lost and error message as shown below will be viewed. To establish a new connection, new IP address must be entered to the SSH Secure Shell program.

IP ADDRESS DEFINITION OF PCU200 BLOCK

Page 27: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

27

IP ADDRESS DEFINITION OF CC CARD

Page 28: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

28

IP ADDRESS DEFINITION OF CC CARD

• In order to define IP address to the CC card, “Telnet” connection to CC card must be available. Then, the necessary commands as shown below are entered for IP address definition.

NOTE: For this connection, Putty or other Telnet programs can also be used.

Page 29: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

29

• At the maintenance computer, select Run option at the Start menu. Type the following command to provide Telnet connection to the CC Card:

“telnet -t vt100 192.168.128.179” ( It is assumed that the IP address of the CC card is 192.168.128.179. )

The screenshot below shows how to make this process.

IP ADDRESS DEFINITION OF CC CARD

Page 30: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

30

• At the Telnet window enter the following user name and password:

Username ( login ) : root

Password : ds200

IP ADDRESS DEFINITION OF CC CARD

Page 31: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

31

• Type the following command to change the IP address and NetMask

address:

“ chgip 192.168.128.180 255.255.255.0 ”

IP address of the CC card is changed as 192.168.178.180. Additionally, NetMask IP address is changed to 255.255.255.0.

IP ADDRESS DEFINITION OF CC CARD

Page 32: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

32

IP ADDRESS DEFINITION OF CC CARD

Page 33: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

33

IP ADDRESS DEFINITION OF

PPC SS7 CARD

Page 34: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

34

• Connect PPC SS7 card’s serial port (which is next to the ethernetentry) to the maintenance computer by a proper serial port cable. Pin connections of this cable is shown below :

NOTE: Before or after this connection, PPC SS7 end or maintenancecomputer end of this cable should not be remained unconnected. In sucha case, the cable is subject to external effects (like noise).

Page 35: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

35

• Run Hyperterminal and select the proper port number.

HYPERTERMINAL CONNECTION

Page 36: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

36

● Bits per second 115200 ● Data Bits 8● Parity None ● Stop bits 1● Flow Control None

• Then, the settings in the figure below should be done.

HYPERTERMINAL CONNECTION

Page 37: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

37

• Run Hyperterminal and press ENTER button to see $ command prompt.

HYPERTERMINAL CONNECTION

Page 38: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

38

COMMANDS AT THE HYPERTERMINAL PROGRAM

• Type reboot in the $ command prompt. Then press ENTER key and press ESC key immediately to see dcc> prompt.

Page 39: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

39

• Enter the following commands in the given order, when dspbank> prompt appears.

IP ADDRESS DEFINITION OF PPC SS7 CARD

a) dspbank> printenv ipaddr The IP address of the PPC SS7 card can be viewed by this command.

b) dspbank> setenv ipaddr 192.168.2.183 A desired IP address is defined for the card by this command.

c) dspbank> printenv ipaddr The IP address of the PPC SS7 card can be checked by this command.

d) dspbank> saveenv The entire operations performed above are saved by this command

(Note: Write IP and MAC addresses of the PPC SS7 card on a paperbefore following the procedure below.)

Page 40: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

40

IP ADDRESS DEFINITION OF PPC SS7 CARD

Page 41: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

41

• Commands below can be used for Server IP address and MAC address setting & viewing operations.

COMMANDS AT THE HYPERTERMINAL PROGRAM

(Note: ServerIP adress is the IP address of the server computer on which ktftp.exe runs. )

e) dcc> printenv serverip The IP address of the server computer, on which ktftp.exe runs is viewedby this command.

f) dcc> setenv serverip 192.168.2.66 The IP address of the server computer, on which ktftp.exe runs is changedby this command.

g) dcc> printenv serverip The IP address of the server computer, on which ktftp.exe runs is checkedby this command.

Page 42: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

42

h) dcc> printenv ethaddrThe MAC address that has been defined for the DCC Utility card is viewedby this command.

i) dcc> setenv ethaddr 00:08:d1:02:08:bd A MAC address is defined to the DCC Utility card by this command.

j) dcc> printenv ethaddrThe MAC address that has been defined for the DCC Utility card is checkedby this command.

IMPORTANT: MAC address definition operation should not be done without receiving the approval of the Karel experts

NOTE: IP and MAC addresses used above are given as an example.

COMMANDS AT THE HYPERTERMINAL PROGRAM

Page 43: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

43

SOFTWARE LOADING - UPDATING

Page 44: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

44

WinSCP PROGRAM

• WinSCP is used for making the file transfer between the devices in the same network.

• WinSCP is installed on the maintenance computer.

• WinSCP is a Windows O.S - based program.

Page 45: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

45

• After the installation of the program WinSCP is completed, type the IP address of the PCU200 ( Linux PC ) as the Hostname in the main window. The username and the password are entered as follows.

Username: root

Password: ds200L

WinSCP PROGRAM

Page 46: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

46

• To store these settings for future connections, click Save option. Then click Login to establish the connection.

WinSCP PROGRAM

Page 47: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

47

• The left half of the window that opens shows the folders on the maintenance PC ( Windows ) , while the right half displays the ones on the PCU200 ( Linux ).

• Press icon at the right - top side to reach the upper folders.

WinSCP PROGRAM

Page 48: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

48

• See etc and karel directories on the window (these directories are loaded to the PCU200 computer by default). But it will be useful to check them.

• Make sure that hosts file is existing under etc directory.

WinSCP PROGRAM

Page 49: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

49

DIRECTORY ETC

Page 50: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

50

• If redundant PCU200 computer is available in the system, IP address of the redundant PCU200 must be written into the corresponding part of same row with the x2 definition in the hosts file under the etc directory.

HOSTS FILE

Page 51: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

51

• Make sure that the files and directories under karel directory shown in the figure below are existing.

DIRECTORY KAREL

Page 52: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

52

ARPSAVE FILE

• Reach arpsave file under the directory karel/sbin. Write IP and MAC addresses of the CC cards into this file as shown in the format below .

• After setting this file properly, use ping command in the SSH Secure Shell program to check connectivity to CC cards.

Page 53: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

53

• In order to define DCC block and the towers to the DS200L system, reach pbxcomm.conf file under the karel/home/conf directory. Right-click and select Edit option.

• It is MANDATORY to write the IP addresses of the towers ( CC cards ), PPC SS7 Card and DCC block into this file. Because when the system is started, system will know which towers and the IP addresses to be communicated by means of the pbxcomm.conf file .

PBXCOMM.CONF FILE

Page 54: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

54

• pbxcomm.conf includes explanations for correct settings. The settings can be entered after these explanations.

• IP addresses typed as “ cc ” will be the IP addresses of the towers. IP addresses typed as “ vr ” will be the IP adresses of virtual towers, IP addresses typed as “ ss7 ” will be the IP address of the PPC SS7 Card and the IP address typed as “ dcc “ will be the IP address of the DCC block, in other words IP address of the DCC Utility Card .

• The IP address typed into the 1st row is known as the 1st tower by the system and this order is followed.

• Maksimum 16 towers can be defined to a DS200L system for now.

PBXCOMM.CONF FILE

Page 55: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

55

PBXCOMM.CONF FILE

Page 56: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

56

LOADING THE MASTER SOFTWARE

OF THE SYSTEM

Page 57: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

57

• Main (master) software of the system runs on the PCU200 computer and exists under karel/bin directory. Loading this software is done via WinSCP program.

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 58: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

58

• The master software that is to be loaded is copied to the karel/bin folder on the maintenance computer previously. This software can be viewed in the WinSCP program at the left side of the figure below .

• Then this master software is copied to the karel/bin folder on the PCU200 which is at the right side of the figure below.

• As the figure below shows, there may be several master softwares and rpm files under the karel/bin folder ( the files which has .rpm extension are zipped files). Use the command “rpm - ivh - -force zr_xxx.rpm” to determine which master software will be running on the system (details are given in the next pages).

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 59: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

59

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 60: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

60

• After copying the new master software, run SSH Secure Shell program.

• Reach the root prompt, type cd/karel/bin and press ENTER key.

• Run the following command:

“rpm - ivh - -force zr_acb_15.rpm “

• By this command, some directories& files are formed under zr_acb_15 directory.

NOTE1: zr_acb_15.rpm is given as an example of master software. NOTE2: After entering “rpm - ivh - -force zr_acb_15.rpm”

command, the system should be stopped by the stop command in the SSH Secure Shell program.

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 61: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

61

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 62: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

62

• Enter “check zr_acb_15” command entered in the SSH Secure Shell program to set read-write-execute (r-w-x) permissions of all the files under karel directory ( zr_acb_15 is given as an example of a master software ).

• This command also upgrades software version information written in the dsinit.conf file automatically. Then, in the WinSCP program, check if the the master software information under the karel/home/conf/ dsinit.conf is upgraded or not.

NOTE: If check command does not operate, ( r-w-x ) permissions of the

check file must be checked.

LOADING THE MASTER SOFTWARE OF THE SYSTEM

Page 63: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

63

• After loading is completed, enter start command in the SSH Secure Shell program to restart the system.

LOADING THE MASTER SOFTWARE OF THE SYSTEM

• Then use dslog command to check that the system is running.

Page 64: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

64

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 65: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

65

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

• Loading the software to the DCC Utility card is done via Hyperterminal program.

• Initially, 3 software files exist on the DCC Utility card. Those are U-Boot, Kernel and MTD. Except special requirements, U-Boot and Kernel files will not be upgraded.

• When the software changes related to the DCC Utility card are performed, the software to be loaded to the card is MTD ( image.jffs2 ). How to load the MTD software is explained below.

Page 66: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

66

• DCC 8E1 Interface cards are upgraded automatically when MTD software is upgraded. If MTD software is upgraded, then there is no need to upgrade the softwares of the DCC 8E1 Interface cards which is performed via DCC IDEA connection.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 67: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

67

• In the maintenance computer, copy ktftp.exe file into a folder. Copy MTD software into the same folder as well and then run ktftp.exe file.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 68: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

68

• Make Hyperterminal connection with a proper serial port cable as explained in the previous chapters.

• Run Hyperterminal program and press ENTER key to reach $ command prompt.

• Type “reboot” in $ command prompt of the Hyperterminal window. Press ENTER key and then press ESC immediately, to reach dcc> command

prompt.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 69: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

69

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 70: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

70

• In dcc> prompt, use the following commands:

– run save_mtd

Loads MTD software into the DCC Utility Card.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 71: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

71

b) setenv bootcmd run flash_mtd

Loads MTD software into the flash on the DCC Utility card.

c) setenv bootdelay 3

Sets the delay at the starting of the DCC Utility card to 3 seconds.

d) saveenv

Saves the entire operations performed above.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 72: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

72

• The screenshot related to the commands explained above is shown below.

UPDATING THE SOFTWARE OF THE DCC UTILITY CARD

Page 73: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

73

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 74: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

74

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

• Loading the software to the PPC SS7 card is done via Hyperterminal program.

• Initially, 3 software files exist on the PPC SS7 card. Those are U-Boot, Kernel and MTD. Except special requirements, U-Boot and Kernel files will not be upgraded.

• When the software changes related to the PPC SS7 card are performed, the software to be loaded to the card is MTD ( image.jffs2 ). How to load the MTD software is explained below.

Page 75: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

75

• In the maintenance computer, copy ktftp.exe file into a folder. Copy MTD

( image.jffs2 ) software into the same folder as well and then run ktftp.exe file.

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 76: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

76

• Make Hyperterminal connection with a proper serial port cable as explained in the previous chapters ( IP Definition of PPC SS7 Card part).

• Run Hyperterminal program and press ENTER key to reach $ command prompt.

• Type “reboot” in $ command prompt of the Hyperterminal window. Press ENTER key and then press ESC immediately, to reach dcc> command

prompt.

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 77: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

77

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 78: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

78

• In dspbank> prompt, use the following commands:– run save_mtd

Loads MTD software into the PPC SS7 Card.

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 79: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

79

b) setenv bootcmd run flash_mtd Loads MTD software into the flash on the PPC SS7 card.

c) setenv bootdelay 0 Sets the delay at the starting of the PPC SS7 card to 0 seconds.

d) saveenv Saves the entire operations performed above.

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 80: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

80

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 81: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

81

NOTE: If all these operations can not be completed in 5 minutes, card

will be turned OFF. After turning ON the card, remaining operations will

be done.

UPDATING THE SOFTWARE OF THE PPC SS7 CARD

Page 82: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

82

UPDATING THE SOFTWARE OF THE DCC 8E1 INTERFACE CARDS

Page 83: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

83

UPDATING THE SOFTWARES OF THE DCC 8E1 INTERFACE CARDS

• The software versions of the DCC 8E1 Interface cards are upgraded via DCC IDEA connection.

• Firstly, reach DCC block by entering the IP address of the DCC Utility card into the IDEA program as explained in the previous sections.

Page 84: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

84

• Then, select “Card Firmware Upgrade” menu at DCC IDEA and click “Copy to Cards” icon to update software versions of all DCC 8E1 Interface cards.

UPDATING THE SOFTWARES OF THE DCC 8E1 INTERFACE CARDS

Page 85: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

85

USING

SSH SECURE SHELL

PROGRAM

Page 86: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

86

• The SSH Secure Shell program is an interface Program which used to manage the system and to access master and slave (if exists) Linux PCs ( PCU200) in the DS200L system.

• After the installation of the SSH Secure Shell program is completed, following the steps below will be convenient.

USING SSH SECURE SHELL PROGRAM

Page 87: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

87

STEPS AFTER THE INSTALLATION

1) The default window that opens after running the program is shown below.

Page 88: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

88

SSH SECURE SHELL

2) It is possible to define new profile through the window below by selecting

“Add Profiles” option. Master and slave Linux PCs can be defined by this

way. This will make later connections easier.

Page 89: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

89

3) Define a profile name for Master PC, which is the PCU200 computer

running in the system.

SSH SECURE SHELL

Page 90: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

90

4) Select Profiles/ Edit Profiles in the menu to make profile settings.

SSH SECURE SHELL

Page 91: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

91

5) Enter the IP address of the Master PC into the Host Name part. Type root in the UserName part.

SSH SECURE SHELL

Page 92: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

92

6) Select the pre-defined profile from Profiles for connection to the Master PC.

SSH SECURE SHELL

Page 93: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

93

7) Enter ds200L as the password.

SSH SECURE SHELL

Page 94: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

94

8) Reach root command line, as shown below.

SSH SECURE SHELL

Page 95: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

95

IMPORTANT COMMANDS

USED IN

SSH SECURE SHELL PROGRAM

Page 96: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

96

COMMANDS AT SSH SECURE SHELL

1) stop command is used to stop the DS200L system. And start

command is used to power OFF&ON the system.

Page 97: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

97

2) date –s hh:mm sets the clock.

COMMANDS AT SSH SECURE SHELL

Page 98: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

98

3) ifconfig lists the Ethernet cards that have been defined on the PCU200.

COMMANDS AT SSH SECURE SHELL

Page 99: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

99

4 ) check r_aca_x sets the read - write - execute (r-w-x) permissions of the files.

(r_aca_x is an example of the main software version of the exchange.)

COMMANDS AT SSH SECURE SHELL

Page 100: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

100

5) dslog shows basic information: stop & start times of the system, connection status of the towers and some software versions.

6) dslog|more lists the log information page by page.

COMMANDS AT SSH SECURE SHELL

Page 101: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

101

IDEA- DS200L

SYSTEM CONNECTION

Page 102: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

102

IDEA – DS200L CONNECTION

• Type IP address of the active PCU200 computer in the “NetConsole Server” tab in IDEA to establish a connection.

Page 103: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

103

• After the connection to the IDEA program of DS200L system is established, configuration window shown below can be viewed. Required programming

of the DS200L system can be done.

IDEA – DS200L CONNECTION

Page 104: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

104

IDEA - DCC

CONNECTION

Page 105: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

105

IDEA – DCC CONNECTION

• Type IP address of DCC ( IP address of the DCC Utility Card ) in the DCC Connection tab in IDEA to establish a connection. After the connection, access the DCC rack and make the required programming.

Page 106: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

106

DCC CONFIGURATION

Page 107: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

107

DCC CONFIGURATION

• The E1 ports that have been labeled green in this window are the ports over which the connection to the UTIL-4E1 cards and the towers are established. The E1 ports labeled as red shows the ports dedicated to virtual towers.

• In this window, hardware and software versions of an 8E1 card are viewed, if the mouse cursor rests on that card for a while.

Page 108: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

108

E1 LINE INFORMATION

Page 109: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

109

• This window shows the 8E1 cards that have been installed in DCC slots, and the towers they have been connected to.

• For instance, regarding the “E1 #” row in the figure above, the first E1 port of the 8E1 card, that is in the slot 0 of the DCC Card, is in connection with the E1 port 0 of the first rack of the first tower.

E1 LINE INFORMATION

Page 110: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

110

• The relay row indicates whether there is a problem with the relay of that E1 port.

• The SYNC row indicates whether there is synchronization problem with the pertaining E1 port. Green color signifies that synchronization has been maintained.

• The external clock row indicates the ports over which the external clock signal of the system is received.

- When you click the EXCLK cells of the ports, to receive external clock, they are labeled blue.

- The port over which the external clock signal is currently being received appears in dark blue. In case any problem with that port occurs, the system automatically starts to receive the external clock signal over another port that has been labeled blue, so that continuous reception of the system clock is maintained.

E1 LINE INFORMATION

Page 111: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

111

• The SLIP rate row values are supposed to be 0 for normal operation of the system. Any value that is different from 0 indicates that there is a problem with cabling or connection.

• In case there is problem with the 2 Mbit connection, the Local Loopback

row indicates that the problem originates from the pertaining port. That test has been explained in the BERT window.

E1 LINE INFORMATION

Page 112: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

112

BUSYNESS STATUS OF CHANNELS

• This window displays the busyness status of 32 channels on the ports of DCC 8E1 Interface cards. The first channels of the ports have been marked as SYNC.

• The channels which are assigned as LINK are continuously in BUSY status.

Page 113: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

113

BERT (BIT ERROR RATE TEST)

• BERT is a test performed in order to see if there is a problem with a line or cabling. It can be be peformed on the basis of lines or channels.

• To start the test, put the desired line into blue LOCL mode by right clicking it on the Local Loopback row.

Page 114: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

114

BERT

NOTE: Loopback operation can also be performed with a short cable. A short

cable is inserted into the related port. Other end of this cable is connected

matching as Rx1-Tx1 and Rx2-Tx2 and the procedure below is followed.

● BERT window is accessed and the lines which will be tested are selected.

Also the duration of the test can be set, as shown in the figure below. .

Page 115: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

115

BERT

• Number of errors occurred on the tested lines and error percentages are viewed as shown in the figure below.

NOTE: The LINK channel must not be tested,or that causes link to be broken.

Page 116: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

116

CONSOLE

• If you type “help” command and press ENTER key in this window, you can see the commands that can be used in the window, together with their functions.

Page 117: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

117

VIRTUAL TOWER

► The ports signed as “Virtual Tower” are the ports which are connected to the SS7 Network. • Selection of the virtual towers are done via this window. The E1 ports selected at the left side are assigned as Virtual Towers when they are carried to the rightside of this window.

Page 118: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

118

PLL ( PHASE - LOCKED LOOP ) STATUS

Page 119: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

119

PLL (PHASE-LOCKED LOOP) STATUS

• The purpose of this window is to display parameters for PLL; values of parameters cannot be changed

• The PLL block is on the DCC Utility card. Synchronization with the external clock signal received from the 8E1 lines can be maintained by PLL.

• It is essential to make sure that PLL state appears to be “Locked” in this window, because it indicates that the clock is active.

• All values are supposed to be as shown in the figure above.

Page 120: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

120

CADENCE

• DCC Block produces the “Alerting” and “Hold” tones for the calls which are done through SS7. Arranging the duration of these tones are done via this window.

Page 121: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

121

DATE / TIME

• Date and time parameters of DCC can be set through this window. Synchronization with the PC clock is also possible.

Page 122: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

122

NON-VOLATILE MEMORY OPERATIONS

• Operations related to non-volatile memory are performed through this window. Any change that has been made must be written to the non-volatile memory to be permanent.

Page 123: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

123

HOW TO LOAD CARD SOFTWARE

• The software files of the DCC 8E1 Interface cards are loaded through this window.

Page 124: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

124

USER/ SECURITY OPERATIONS - Users

• Users with different authorization levels in IDEA can be defined through this window.

Page 125: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

125

SECURITY OPERATIONS – Changing Password

• The password required for logging in to DCC

IDEA can be changed through this menu.

Page 126: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

126

SECURITY OPERATIONS – OPERATION TRACKING RECORDS • Operations that have been performed in the system can be tracked

through this window.

Page 127: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

127

SETTINGS - Operation Tracking

• Through this window, it is determined whether operation tracking will be active or not, and the number of records to be kept in the log file is set. Hence, the modifications made through IDEA will be traceable.

Page 128: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

128

SETTINGS – Log File

• Log information related to DCC communication can be recorded through this window. Also the size of the log file can be adjusted.

BUT ; in case of a problem, the log information that is obtained by connecting to DCC through HyperTerminal will be more detailed and useful. How to obtain log file through Hyperterminal for DCC is explained at “Obtaining Log File “ section .

Page 129: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

129

OBTAINING LOG FILE

• LOG FILE OF THE SYSTEM

• ETHEREAL LOG

• HYPERTERMINAL LOGS OBTAINED FROM DCC BLOCK

• LOGS OF THE PPC SS7 CARD

Page 130: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

130

LOG FILE OF THE SYSTEM

Page 131: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

131

LOG FILE OF THE SYSTEM

When it’s required to obtain log file from DS200L system: • Establish a SSH Secure Shell connection

• At the root command line, type dslog tar and press ENTER key.

• All the files under the directory karel/home/log are zipped and a new file named log.tar.bz2 is formed.

It will be necessary and enough to send this file to Karel.

Page 132: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

132

• In order to follow the flowing of the system’s log at that moment, you can use “dslog” command at the SSH Secure Shell program. Thanks to “dslog” command, system’s start&stop times, active towers and some information about the versions can be observed.

• By the “ dslog |more “ command, these logs can be viewed page by page.

LOG FILE OF THE SYSTEM

Page 133: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

133

LOG FILE OF THE SYSTEM

Page 134: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

134

Log of IDEA Program: Log of the IDEA program also exists in thesystem’s log. At DS200L systems, normally, analyzing the system’s logwill be enough. But it may not be easy to view the IDEA log inside thesystem’s log when the size of system’s log is too big. If necessary, IDEAlog can be analyzed seperately.

• Obtaining the log file of IDEA program at DS200L systems is similarto DS200 systems. When IDEA program is run, a text based file underthe directory which IDEA program is installed is formed automatically. Inthis file, log files of that current session of the IDEA are saved.

LOG FILE OF THE SYSTEM

Page 135: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

135

ETHEREAL LOG

Page 136: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

136

• Ethereal is a network analyzer and shows IP signaling & speech logs. It is an open source program and can be downloaded easily from internet.

• Since DS200L system communicates over LAN through TCP/IP, Ethereal logs are useful to observe communication problems in DS200L communication.

ETHEREAL LOG

IMPORTANT: In order to obtain usable Ethereal logs, programmable network switch or hub is needed.

Page 137: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

137

• Run SSH Secure Shell program and see the list of ethernet cards at the PCU200 computer by the ifconfig command.

ETHEREAL LOG

Page 138: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

138

● “tcpdump” command forms a file in the PCU200 computer. That file contains Ethereal logs.

ETHEREAL LOG

Page 139: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

139

• When there is a problem at the system and log of this problem is required:

- Run IDEA program

- Double click the LOG icon at the right-bottom side of the IDEA window and reach the log window. After clearing the log window, generate the problem again.

- Copy and paste the log messages and save them in a text file in the maintenance computer.

LOG FILE OF THE SYSTEM

Page 140: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

140

This command is entered as :

“ tcpdump -i eth1 –C 10 –s 1500 –w ethereal “

• -i ( interface ) : shows which interface ( Ethernet card ) is being used.

• eth1: shows the “eth1” named ethernet card is being used.

• -c (capacity ): shows the capacity of logs are saved. Example: -c 10 -> shows the logs will be saved as 10MB sized.

• -s ( snap ): amount of data for each frame ( in terms of byte). If not defined, it’s 68 byte.

• -w ( write ) : determines the name of the ethereal file to be saved under the root directory. In the example above, name of this file is written as “ethereal” for easiness. If desired, this file can be saved in another name.

ETHEREAL LOG

Page 141: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

141

• To obtain Ethereal logs, type IP address of PCU200 computer and run WinSCP program.

• Copy the file named ethereal from root directory to the maintenance computer. Send this file to Karel.

ETHEREAL LOG

Page 142: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

142

• If necessary, content of these logs can be viewed by following the steps below (The screeenshots below are obtained from the Wireshark program which is the latest version of Ethereal program).

• You can open the Ethereal log file from “File/Open” option on the main menu.

ETHEREAL LOG

Page 143: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

143

ETHEREAL LOG

Page 144: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

144

• Logs can be viewed after selecting the required Ethereal log file.

ETHEREAL LOG

Page 145: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

145

HYPERTERMINAL LOGS

OBTAINED FROM

DCC BLOCK

Page 146: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

146

HYPERTERMINAL LOGS OBTAINED FROM DCC BLOCK

• It will be useful to get the logs via Hyperterminal program for analyzing and solving the problem. Hyperterminal connection to DCC block is done as explained in the previous chapters.

• In order to get Hyperterminal logs, proper serial port cable should be connected and hyperterminal program should be running on the maintenance computer. A sample screenshot of hyperterminal log flowing window can be viewed below.

Page 147: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

147

HYPERTERMINAL LOGS OBTAINED FROM DCC BLOCK

Page 148: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

148

• If necessary, logs on the hyperterminal window can be copied to a text file or “ Transfer /Capture Text ” option can be used to save so these logs to a file.

HYPERTERMINAL LOGS OBTAINED FROM DCC BLOCK

Page 149: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

149

LOGS OF THE

PPC SS7 CARD

Page 150: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

150

LOGS OF THE PPC SS7 CARD

• Especially for the LINK problems, it will be useful to get the logs via Hyperterminal program for analyzing and solving the problem. Hyperterminal connection to PPC SS7 Card is done as explained in the previous chapters.

• In order to get Hyperterminal logs, proper serial port cable should be connected and hyperterminal program should be running on the maintenance computer. A sample screenshot of hyperterminal log flowing window can be viewed below.

Page 151: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

151

LOGS OF THE PPC SS7 CARD

Page 152: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

152

• If necessary, logs on the hyperterminal window can be copied to a text file or “ Transfer /Capture Text ” option can be used to save so these logs to a file.

HYPERTERMINAL LOGS OBTAINED FROM DCC BLOCK

Page 153: 1 HIGH CAPACITY PUBLIC SWITCH SYSTEM - MAINTENANCE -

153

THANK YOU VERY MUCH...