Image Receptors

2

Page 3: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Digital

Radiography

DirectCapture

IndirectCapture

Direct-to-DigitalRadiography

(DDR)

ComputedRadiography

(CR)

3

Page 4: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Computed Radiography

Similar to F/S Uses cassettes as imaging plate (IP)

Imaging plate is termed PSP

4

Page 5: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

History of CR

INDUSTRY • Theory of “filmless radiography” first

introduced in 1970

• 1981 Fuji introduced special cassettes with PSP plates (replaces film)

• Technology could not support system

• First clinical use in Japan - 1983 5

Page 6: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Predictions

1980 – Bell Labs believed that Unix would be the worlds dominant operating system

1982 – Bill Gates thought 640K of main memory would suffice for workplace operating systems ( This presentation is 80,000 kb)

1984 – IBM predicted that personal computers would not amount to anything

6

Page 7: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Uses the same generalequipment as F/S

7

Page 8: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

How is it different from F/S?

How the image is captured How the image is stored How the image is viewed How the image is processed after

taken

Computed Radiography

8

Page 9: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Review of F/S image production:

Primary beam Exit radiation Hits phosphors of intensifying screens, lights

helps form image-latent image Some photons hit film directly-latent image Film is processed to develop manifest image Film stored, duplicated to be seen by others

Computed Radiography

9

Page 10: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Computed Radiography Image Production:

Primary beam-same as film Exit radiation-same as film Interacts with CR cassette image plate- latent image latent image -

similar to film CR cassette is place in CR reader, laser translates

image to analog signal-different Analog signal converted to digital signal Image can be viewed on computer monitor-manifest manifest

imageimage Image can be post-processed-not possible with F/S Image is stored in computer system (PACS) Image can be viewed by anyone with access to system Image can be printed on film with a laser printer

Computed Radiography

10

Page 11: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Cassette with film CR with PSP

Film Cassette

CR cassette with PSP

11

Page 12: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Computed Radiography

Responds to radiation by trapping energy in the locations where x-rays strike, creating the latent image

PSP run scanned by a CR reader, converted to analog image, then to digital image, then image viewed on monitor.

12

Page 13: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR Reader- scans the PSP plate

using a RED laser light, releases trapped electrons which then emit BLUE light which is converted to analog image.

13

Page 14: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Computed Radiography

Uses red light to scan

Detects the Blue light emitted

Exit radiation exposes CR cassette

14

Page 15: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR – PSP plate

1. Stimulated by a RED LIGHT

2. Energy is RELEASED in a form of BLUE light

3. LIGHT captured by photomultiplier tube (PMT)

4. Changed to a digital signal 15

Page 16: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

X-rayX-raysystemsystem

PatientPatient

PSPPSPdetector detector

ComputedComputedRadiographRadiograph

1. X-ray Exposure1. X-ray Exposure

ImageImageReaderReader

2.2.

ImageImageScalingScaling

3.3.

ImageImageRecorderRecorder

4.4.

une xposedune xposed

exposedexposed

5.5.

re-usablere-usablephosphorphosphor

plateplate

Computed Radiography

16

Page 17: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR Phosphor PlatesCR Phosphor Plates

ABSORPTION EMISSION

X-RAY

LIGHT

LASER STIMULATION

ELECTRONTRAP

ELECTRONTRAP

17

Page 18: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

How CR works

1. Blue released light is captured by a PMT (photo multiplier tube)(laser reader)

2. This light is sent as a digital signal to the computer

3. The intensity (brightness) of the light – correlates to the density on the image

18

Page 19: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

ERASING PLATE

1. After image is recorded

2. Plate is erased with high intensity white light

3. Cassettes are reused

Remember RED, WHITEWHITE AND BLUE…..but really it goes Red, Blue White…

19

Page 20: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Digital

Radiography

DirectCapture

IndirectCapture

Direct-to-DigitalRadiography

(DDR)

ComputedRadiography

(CR)

20

Page 21: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Directed Digital Radiography

(DDR)

Directed digital radiography, a term used to describe total electronic imaging capturing.

Eliminates the need for an

image plate altogether.

21

Page 22: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Cassette-less imaging Uses TFT-Thin Film Transistor No film, so no developing, No PSP, so CR reader needed Immediate image viewing Post Processing capabilities Multiple viewing stations

Direct Digital Radiography

22

Page 23: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Amorphous Selenium detector technology for DR Direct Radiography

23

Page 24: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Direct Digital Radiography

24

Page 25: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

25

Page 26: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Be able to compare all the different Be able to compare all the different imaging systems. Compare the imaging systems. Compare the

advantages, disadvantages of each advantages, disadvantages of each system. system.

26

Page 27: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

27

FS - Film inside of cassetteFS - Film inside of cassette

CR – Photostimulable Phosphor Plate (PSP)CR – Photostimulable Phosphor Plate (PSP)

DR(DDR) - Thin Film Transistor (TFT)DR(DDR) - Thin Film Transistor (TFT)

Don’t forget about Direct Exposure !!Don’t forget about Direct Exposure !!

Page 28: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

FS vs. CR

CR PSP in cassette Digital image Scanned & read-

CR reader

COMPUTER Image stored on

computer Viewed on a

Monitor Hard copy (film)

can be made with laser printer

FILM Film in cassette loaded in a

darkroom Processed in a

processor

FILM Hard copy image –

stores the image Viewboxes – view

the images 28

Page 29: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR vs DR

CR Imaging plate

Processed in a Digital Reader

Signal sent to computer

Viewed on a monitor

DR Transistor receiver

(like bucky)

Directly into digital signal

Seen immediately on monitor

29

Page 30: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

COMPUTED RADIOGRAPHY & DIRECT RADIOGRAPHY& FILM SCREEN IMAGE CAPTURE

30

Page 31: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Image Resolution (how sharply is the image seen)

CR 4000 x 4000

Image only as good a monitor*

More pixels = more memory needed to store

CR 2 -5 lp/mm RAD 10 lp/mm DR ?

IMAGE APPEARS SHARPER BECAUSE CONTRAST CAN BE ADJUSTED BY THE COMPUTER –

(DIFFERENCES IN DENSITY)

31

Page 32: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

ADVANTAGE OF CR/DR

Can optimize image quality

Can manipulate digital data

Improves visualization of anatomy and pathology

AFTER EXPOSURE TO PATIENT 32

Page 33: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR/DR VS FILM/SCREEN

1. FILM- these can not be modified once processed

2. If copied – lose quality

3. DR/CR – print from file – no loss of quality

33

Page 34: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

“No fault” TECHNIQUES

F/S: RT must choose technical factors (mAs & kVp) to optimally visualize anatomic

detail

CR: the selection of processing algorithms and anatomical regions controls how the acquired latent image is presented for display

HOW THE IMAGE LOOKS CAN BE ALTERED BY THE COMPUTER – EVEN WHEN “BAD” TECHNIQUES ARE SET 34

Page 35: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Storage /Archiving

FILM/SCREEN

1. Films: bulky

2. Deteriorates over time

3. Requires large storage & expense

4. Environmental concerns

CR & DR

1. 8000 images stored on CD-R

2. Jukebox CD storage

3. No deterioration of images

4. Easy access35

Page 36: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

36

Page 37: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

ADVANTAGE OF CR/DR vs FS

1. Rapid storage

2. Retrieval of images NO LOST FILMS!

3. PACS- DICOM (storage management)

4. Teleradiology - long distance transmission of image information

5. Economic advantage - at least in the long run?

37

Page 38: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Transmission of Images

1. PACS - Picture Archiving & Communications System

2. DICOM - Digital Images & Communication in Medicine

3. TELERADIOGRAPHY -Remote Transmission of Images

38

Page 39: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Basics of Digital Images

Digital images are a (matrix) of pixel (picture element) values

39

Page 40: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Analog vs Digital1. Analog - one value

blends into another1. like a thermometer

2. Digital - distinct separation 1. 98.6 2. exact

0

20

40

60

80

100

1st

Qtr

3rd

Qtr

East

West

North

40

Page 41: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CONTRAST & DENSITY

1. Most digital systems are capable of 1024 shades of gray –

but the human eye can see only about 30 shades of gray

2. The Optical Density and Contrast can be adjusted after the exposure by the Radiographer.

3. This is POST - PROCESSING41

Page 42: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

High displayed contrast – narrow window width42

Page 43: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Low displayed contrast (stretched) – wide window width43

Page 44: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Basics of Digital Images

1. Pixel values can be any bit depth (values from 0 to 1023)

2. Image contrast can be manipulated to stretched or contracted to alter the displayed contrast.

3. Typically use “window width” and “window level” to alter displayed contrast 44

Page 45: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Danger of Digital

Then the COMPUTER corrects any exposure errors

Therefore almost ANY technique can be used on the patient –

The computer will fix it

45

Page 46: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

DOSE IMPLICATIONS

1. More exposure to the patient2. Techniques established-F/S techniques

3. Higher kVp = Less mAs 4. Less patient dose5. Goes Contrary to what good techs have been

taught

46

Page 47: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

80 kvp 200mas

10 mas 80 kvp

Note

Quantum Mottle

47

Page 48: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Dose Implications

1. Images nearly always look better at higher exposures.

2. Huge dynamic range means nearly impossible to overexpose.

48

Page 49: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

POST PROCESSING

49

Page 50: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

TECHNIQUE CONSIDERATIONS

1.kVp Dependent

2. Now COMPUTER controls CONTRAST

3. Higher kVp to stimulate electron traps

50

Page 51: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

CR – Reader (replaces Darkroom & Processor & Chemicals

Diagnostic Viewer(replaces film, storage & viewboxes)

51

Page 52: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

EMERGING PROBLEMS

1. Better – not necessarily faster

2. Learning curve for technologists and physicians-increase repeat rate?

3. Student applications and issues

4. Pitfalls of CR52

Page 53: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Learning Curve

1. Positioning and proper collimation are critical to good imaging outcomes

2. Just like Phototiming, it can magnify your mistakes

53

Page 54: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

COLLIMATION CRITICAL

1. As the computer reads the density value of each pixel- it is averaged into the total

2. Close collimation= Better contrast

3. Bad collimation= more grays and less detail

54

Page 55: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

To Produce Quality Images

For Conventional Radiography or CR Radiography:

The same rules, theories, and laws still apply and can not be overlooked SID, Inverse Square Law, Beam Alignment ,Tube-Part-Film Alignment, Collimation, Grid, Exposure Factors: kVp, mAs

Patient Positioning

55

Page 56: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Quality Images

56

Page 57: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

Towel that was

used to help in positioning a child

CR/DR is MORE sensitive to ARTIFACTS

57

Page 58: 1  Image Receptors Film Imaging Film Construction Cassette Construction Film Handling Darkroom Digital Imaging Cassette Digital Imaging Direct Digital

58