IR Hall for GLD
Oct. 3. 2006
Y. Sugimoto
KEK
![Page 2: 1 IR Hall for GLD Oct. 3. 2006 Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest](https://reader035.vdocument.in/reader035/viewer/2022072006/56649d0a5503460f949dcbca/html5/thumbnails/2.jpg)
2
Underground hall
Hybrid Pure CMS
IR hall area (WxL) 25x55
Beam height 8.6
Crane max hook height 20.5
Largest item to lift Pieces of yoke
280 t
Concrete shield
100 t
IR hall crane 300 t 100 t
IR hall crane clearance to the roof
TBD by CF group
Resulted total size of the hall (WxLxH)
25x55x35 (height is TBD)
![Page 3: 1 IR Hall for GLD Oct. 3. 2006 Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest](https://reader035.vdocument.in/reader035/viewer/2022072006/56649d0a5503460f949dcbca/html5/thumbnails/3.jpg)
3
Access shaft
Hybrid Pure CMS
Largest item to lower through shaft
Solenoid; 270t/9mx9m Barrel iron ring with solenoid; 2000t / 15mx9m
IR shaft size 16m 20m
IR shaft fixed surface gantry crane
2000t / 1.5y
Surface hall crane should serve IR shaft?
Yes
Other shafts near IR hall for access
No (2 shafts for 2 detectors)
Elevator and stairs in collider hall shaft?
Yes
![Page 4: 1 IR Hall for GLD Oct. 3. 2006 Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest](https://reader035.vdocument.in/reader035/viewer/2022072006/56649d0a5503460f949dcbca/html5/thumbnails/4.jpg)
4
Surface assembly buildings
Hybrid Pure CMS
Surface building area TBD TBD
Largest item to lift Piece of yoke; 280t Inner vacuum tank; 180t for 10cm thick (to be studied)
Surface assembly cranes
300t, 50t 200t, 50t
Surface assembly crane max hook height
25m (vertical installation of coil into cryostat)
Surface assembly crane clearance to the roof
TBD by CF group
Resulted volume of surface assembly hall
TBD
![Page 5: 1 IR Hall for GLD Oct. 3. 2006 Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest](https://reader035.vdocument.in/reader035/viewer/2022072006/56649d0a5503460f949dcbca/html5/thumbnails/5.jpg)
5
Crane access
Hybrid Pure CMS
Surface assembly hall crane access area
TBD TBD
IR hall crane access area (WxL)
18x39
Max detector height 15.8 (=8.6+7.2) (Cables, cryogenic apparatus, etc., not included)
Detector diameter 14.4
Minimum detector clearance
X; 5.2 (to wall)
Z; 5.0 (to wall)
![Page 6: 1 IR Hall for GLD Oct. 3. 2006 Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest](https://reader035.vdocument.in/reader035/viewer/2022072006/56649d0a5503460f949dcbca/html5/thumbnails/6.jpg)
6
Others
Hybrid Pure CMS
Electronics hut 4x10x10(m3)x2huts
Electronics hut location
Against wall at both sides
When the e-hut is installed underground
After assembly of detector