1 must2 exp e655s @ ganil vamos [email protected] e655s configuration t1 to t4 t6, t7 t5, t8 beam

16
1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea. fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

Upload: leonne-basset

Post on 03-Apr-2015

113 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

1MUST2 exp E655S @ GANIL VAMOS [email protected]

E655S configuration

T1 to T4

T6, T7

T5, T8

beam

Page 2: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

2MUST2 exp E655S @ GANIL VAMOS [email protected]

E655S- configuration des télescopes pour l’expérience - sept 2013

MM1Si-strips

+ CsI

MM4Si-strips

+ CsI

MM2(dssd6)

CsI

MM3(dssd7)

CsI

1, 2 3 and 4: LONG config

6,7 Long

MM6Si-strips (dssd2) SiLi+ CsI

MM7Si-strLPCSiLi+ CsI

Colonne de gauche

MM5Si-strips

SiLi

MM8Si-strips

SiLi

5,8 short config

Colonne de droite

Statut des blocs et des DSSD et SiLi montés sur les télescopes:MM1 dssd +CsI ; DSSD pcb 6 MM2 = dssd de dssd6 +CsI DSSD pcb 9 MM3 dssd +CsI ; DSSD dssd de T7 DSSD pcb 10MM4 = dssd+CsI DSSD pcb 5 dssd: serial number: 2274-24MM5 ; BLOC REPARE (fuite) DSSD pcb 4 MM5 SiLi : ST9-7 ST9-20MM6 dssd+SiLi + CsI DSSD pcb 2 dssd du 2iniserial number 2489-8 MM6 SiLi : ST9-12 ST9-13 MM7 dssd +SiLi CsI ; DSSD pcb 7 dssd: Si-strLPC MM7 SiLi : ST9-27 ST9-14prob de connectique (vérifier les câbles internes BT du T7) , MM8 dssd +SiLi DSSD pcb 8 MM8 SiLi : ST9-4 ST9-26

Sondes de Température sur T2, T4 et T5, T6

T1 to T4

T6, T7

T5, T8

beam

MM1, MM2 okMM3 ok sauf XTMM4 : okMM7 : OffMM5 ok, MM6 ok sauf stripXEMM8 bruits en Ordi /dec

Numéros suite au changement de config d’août

Page 3: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

3MUST2 exp E655S @ GANIL VAMOS [email protected]

Les 8 télescopes – ref pcb, dssd, SiLi CSI, tensions/courants le 5 septembre 2013

TELNUMBER

ModuleDSSD

pcb /dssd

DSSD HT V ; I(µA)

SiLi-1; SILi-2Julich ; V, (I µA)

CsI V, (I µA)

Remarks T=-5°CCooling Problems

(Leakage, Currents)

1 Pcb6Notation « pcbT6 »

-60V; (0.67) 0; -50V (CsI)

X-ET,Y-ET ok

2 pcb 9Pcb « 9X »

-80V; (0.40) 0; -50V (CsI)

X-ET,Y-ET okSonde 0.3°C

3 pcb 10Notation pcb«X »

-80V; (1.21) 0; -50V (CsI)

Problème XT X-E,Y-ET ok

4 pcb5« 2274-24 »

-70V; (0.84) 0; -50V (CsI)

X-ET,Y-ET okSonde 0.0°C

5 pcb 4 -70V; (3.78) +300V (3.9), +650V (8.12);

-50V (CsI)

X-ET,Y-ET ok

6 pcb 2« 2489-8 » « 2X »

-60V; (0.85) +350V (5.04), +700V (2.48);

-50V (CsI)

X-ET,Y-ET ok; missing XESonde -1.1°C

7 OFF (BT/HT)

Pcb7« X  MUST 7 »

(-70V) OFF +350V ( ), +350V ( ); -50V (CsI)

+2.5V, -2.5V courant débitétrès faible (~0.1A au lieu de

1.2A)

8 OFFBRUIT

Pcb8« pcb T8 »

-80V; (1.1) +700V (3.18), +700V (1.82);

-50V (CsI)

Déclenchement sur du bruit

Page 4: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

4MUST2 exp E655S @ GANIL VAMOS [email protected]

Détecteurs DSSD de réserve

Détecteurs Si MM Boîte des DSSD (armoire MUST2-labo SPEG) Le dssd “pcb 4” était monté sur T5 ; il a été ôté pour effectuer la calibration des SiLi.Le dssd “pcb 2” (notation 2489-8) était monté sur T6 ; idem, enlevé pour calibrer les SiLi.

DSSD additionnels :

+ dssd pcb3 dans son boîtier+ dssd pcb1 (tâche sur la surface)

Le dssd nouveau livré par Micron en septembre sera noté “pcb 11”. Il devra être testé.

NB: le pcb 10 monté sur T3 lors de E655S sera mesuré par le géomètre.

Page 5: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

5MUST2 exp E655S @ GANIL VAMOS [email protected]

configurations des MUST2: numéros des pads CsI

Telescopes Si à strips DSSD2 étagesMM1 à MM4: DSSD+CsI

T1 T2

T4 T3

1 2 3 4

8 7 6 5

12 11 10 9

16 15 14 13

16 12 8 1

15 11 7 2

14 10 6 3

13 9 5 4

13 14 15 16

9 10 11 12

5 6 7 8

4 3 2 1

4 5 9 13

3 6 10 14

2 7 11 15

1 8 12 16

1128 Y

128

1

X

128

1

Y

1128 X

1 128X1 128Y

128

1

Y

128

1

X

1

4

2

3

Page 6: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

6MUST2 exp E655S @ GANIL VAMOS [email protected]

Numéros des pads CsI pour tél 6 et 7 (config longues) et pads SiLi (« b ») pour tél 5 et 8.

Telescopes 2 étages Si à strips et SiLi MM6, (MM7)DSSD+SiLi Julich+CsI

MM5,(MM8)DSSD+ SiLi Julich

T6

T7

13 14 15 16

9 10 11 12

5 6 7 8

4 3 2 1

9 11 14 16

10 12 13 15

2 4 5 7

1 3 6 8

128

1

Y

1128 X

1 128Y128

1

X

5(8)

6(7)

T5 b

T8 b

b1 b2 10 9

3 4 12 11

6 5 13 14

b8 7 15 16

b8 6 3 b1

7 5 4 b2

15 13 12 10

16 14 11 9

1128 Y

128

1

X

1 128X

128

1

Y

Page 7: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

7MUST2 exp E655S @ GANIL VAMOS [email protected]

CAEN SY1527 configuration for 6 telescopes LOW/ HIGH VOLTAGES

Distribution box for telescopes T1 to T6with power supply (low voltage) from Slots 0, 1 and 2

SLOT 0A1518B

OUT A3X +2.5V

OUT B3X -2.5V

SLOT 1A1518B

OUT A3X +2.5V

OUT B3X -2.5V

SLOT 2A1516A

OUT A1X +3.3 V2X -5V

OUT B2X +5V1X +10V

SLOT 13A1835P12ch.

SLOT 14A1837N12ch

SLOT 15A1837N12ch.

For telescopes T1 to T6power supply (high voltage) Slots 13, 14, 15

A1837N Quantity : 2-250V/1mA (100µA) -50V( CsI), -100V (Si)

A1835P+1.5kV/7mA (200µA)+HT SiliJulich

Page 8: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

8MUST2 exp E655S @ GANIL VAMOS [email protected]

Câbles MUST2, boîtiers de distribution

Distribution BOX for 6 telescopes T1 to T6

BOX for telescopes T7, T8 Boîtes (cantines) métalliques disposées dans SPEG

Avec ALIM CAEN SY1527Cantines vertes:

NB Les 2 boîtiers de distributionsont placés dans la plus grande. Le boîtier pour T1-T4 est situé sur le dessus.

Les autres contiennent la mécanique (supports,Pieds pour les mesures géométriques…)

Boîte (cantine) métallique gris argent:Câbles externes MUST2 SA/SL pour 8 télescopesCâbles ECL pour 8 “ORDI “(câbles MUVI vers ECL-NIM)Câbles sondes de température pour le contrôle commande de l’alim CAEN

1 jeu de câbles pour ADC

Page 9: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

9MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept- MM1 ok énergies

Page 10: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

10MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept MM2 ok énergies

Page 11: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

11MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept MM3 ok énergies

Page 12: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

12MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept MM5 ok énergies

Page 13: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

13MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept MM4 ok énergies

Page 14: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

14MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration source Alpha -23 sept -MM6 problème pistes X

Page 15: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

15MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration en temps-25 sept MM1 – MM4 X calimero

Page 16: 1 MUST2 exp E655S @ GANIL VAMOS vlapoux@cea.fr E655S configuration T1 to T4 T6, T7 T5, T8 beam

16MUST2 exp E655S @ GANIL VAMOS [email protected]

Statut des détecteurs – calibration en temps-25 sept MM1 – MM4 YT calimero