Page 1: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

1

Welcome To the AVO International Meter Adapter Recorder

Presentation

This Presentation will Take about 15 Minutes

Click the Right Arrow Button or Press Enter to Advance

Page 2: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

2

AVO InternationalMeter Adapter Recorders

High Performance Power Monitoring

For Light Commercial/Residential Sites

Page 3: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

3

Requested By Many Utilities

Meter Adapter Recorder Capable of Measuring Voltage and Current of Electrical Service at Meter

Current Values Help Determine Source of Problem(System Side or Load Side)

Safe (no external wires/boxes) Convenient (Meter Forms 2S, 12S, 25S) Extremely Easy To Use

Page 4: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

4

State of The Art Technology

High Speed DSP (Digital Signal Processor)• 256 Samples/Cycle Sample Rate

Flash Memory• Easy Field Upgrades (Enhancements, etc).• Upgrade in Minutes (By You) vs. Days (Factory)

Universal Meter Adapter• 190 A Ring/Ringless

Optically Isolated RS232 Port• Don’t Lose Your Neutral and Feed 120vac to Your Laptop!

Page 5: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

5

Ground Clip- Must be connected

to neutral in meterbase

= Exclusive Feature

Page 6: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

6

Ground Clip

Descriptive LED’sIndicate ProblemsWhile ConnectedTo The ServiceMonitored

= Exclusive Feature

Page 7: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

7

Ground Clip

Descriptive LED’sIndicate ProblemsWhile ConnectedTo The ServiceMonitored

= Exclusive Feature

RemovableJaw to 6 or 9O’Clock Positions(Network Meters)

Page 8: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

8

Manual ON/OFF Switch

Ground Clip

Descriptive LED’sIndicate ProblemsWhile ConnectedTo The ServiceMonitored

= Exclusive Feature

RemovableJaw to 6 or 9O’Clock Positions(Network Meters)

Page 9: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

9

Real Time Display Toggles Between L1, L2 and Countdown Time to Start Recording- Indicates Unit Is Working Properly

Manual ON/OFF Switch

Descriptive LED’sIndicate ProblemsWhile ConnectedTo The ServiceMonitored

Ground Clip

RemovableJaw to 6 or 9O’Clock Positions(Network Meters)

= Exclusive Feature

Page 10: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

10

Pull The Meter

Easy to Install and Use

Page 11: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

11

Plug in the MeterAdapter Recorder

Easy to Install and Use

Page 12: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

12

Plug Meter Into Meter Adapter Recorder and Attach Seal

Easy to Install and Use

Page 13: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

13

DONE!!

Easy to Install and Use

Page 14: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

14

Parameters Measured

2 Line-Neutral Voltages• Calculated L-L Voltage (By adding 256 Samples/Channel)• Works For 120/240v or 120/208v Services

2 Line Currents (L1 & L2) Captive Integral CT’s• Calculates Neutral Current (Subtract 256 Samples/Line

Current)

Page 15: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

15

Operation

You Specify Recorder Response Time, or How Often TRMS Values are Calculated(1 - 60 cycles)

You Specify Data Storage Interval(1 cycle to 4 Hours)

Recorder Automatically Computes TRMS Value per Selected Response Time and Storage Interval

Page 16: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

16

Operation

Recorder Stores Highest, Lowest TRMS Value in Storage Interval as Well as TRMS Value over Storage Interval

Result: You Capture Highest/Lowest 1 Cycle Events/Storage Interval Regardless of Storage Interval Length

This is the 1st Type of Continuous Recording

Page 17: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

17

Out Of Limits Recording

This is the 2nd Type of Simultaneous Recording Based On Limits You Set, Recorder will Separately Start

Logging Events in the Out Of Limits Report as Soon as They are Detected

Limits Can be Set for: Swells/Sags, THD, Spikes as Fast as 65 microsec (1/256th of a cycle)

Page 18: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

18

Use Included 32-Bit, Windows Software to Set Limits

Type of Limit Turn Limit ON

Limit Value THD Limits

Subcycle Transient Limit

= Exclusive Feature

Page 19: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

19

Indicating LEDs

At a Glance, External Indicating LED’s () Tell You if any Events Occurred During the Test.

The GE Flicker Table and a Special Loose Neutral Algorithm are Used.

R Recording/Not Recording

N Suspected Loose Neutral

F Flicker Events

H Harmonic Events

S Swell/Sag/Sub-Cycle Events

= Exclusive Feature

Page 20: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

20

Ease Of Use & Flexibility

Display Tells Installer Unit Is Working And Will Record Correct Values

Countdown Time (Programmable) Tells User Time Before Recording Will Start

Many Different Ways To Start Recording

= Exclusive Feature

Page 21: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

21

StartRecordingWith Manual Switch

CurrentPresent StartsRecording

Specify Starting Date,Time and Length (Hours)

Specify Recording Start Delay Time

Voltage Present Starts Recording

Page 22: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

22

Generating Charts with AVO-Metrosoft is a Snap!

5 - Click on Create!!

1- Select the datafile you Wish to Chart 2- Select

Type Of Chart3- Select Items To Chart

4- Select Trace Colors

Page 23: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

And Here It Is! Ready to Print, Export, or Cut-and-Paste into a Document or SpreadsheetThis is a 19 Day Recording - Notice the Outage

Page 24: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

24

Outage

To Zoom, just hold down the mouse button, drag the cursor to box in the area of interest, release and ZOOM!

Page 25: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

25

Power Quality/Power Flow Options

Two Key Options are Available at a Low Cost

Power Quality Option Captures Waveforms Based on Event (Surge/Sag, THD, Sub-Cycle) Trigger or Time Trigger

You can See Disturbances, Select Waveforms and Do Harmonic Analysis

By Capturing Post-Trigger Cycles, You can See how the Disturbance Resolved Itself

Page 26: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

26

Power Quality Option: Waveform Capture/Harmonic Analysis- Here is a lighting strike in the vicinity of this residence

Page 27: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

27

1 - Select a Waveform with the Cursor

2 - Click on Createfor a HarmonicAnalysis

Harmonic Analysis

Page 28: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

28

HarmonicSummary

SelectedWaveform

Detailed Harmonic AnalysisAnd Here Is The Harmonic Analysis!!

Page 29: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

29

KVAH

KWH

PF

Power Flow Option:Record all Key Power Parameters, Investigate Billing Complaints, Even Look at Vector Relationships

Page 30: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

30

Reports

AVO-Metrosoft Can Automatically Generate Many Different Reports For You:

• Tabular Reports (basic raw data)• Out of Limits Reports (Event Data)• Weekly Energy Report (a whole single week for any one

selected demand parameter)• Voltage Regulation Report

Page 31: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

31

Tabular Report: Voltage/Current

Page 32: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

32

Note that Power by phase as well as total, and also true pf,displacement pf,voltage and current imbalance per demand interval are presented.

Tabular Report: Demand

Page 33: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

33

Out of Limits Report (Event Data)

Event Details

Event Summary with

type of event

Page 34: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

34

Summary

Why have we built so much power into a residential unit?• Because Power Quality Problems Have Found Their Way into

The Home–Many Home Offices with Sensitive Equipment and

UPS’s/Surge Arrestors–Chips in Many New Appliances

• To Protect Your Investment With De-regulation, Power Quality Problems in the

Home/Light Commercial are Going to Get Worse, Not Better

Page 35: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

35

Summary, Continued

mr-2/4 Using Advanced Technology Offer:• Ease of Use, Flexibility, Versatility• Fast, Easy Field Upgradeability

Users can Start with the Simplest Unit and Add Power Quality and/or Power Flow Options when and if They Want to Make Their Unit Almost into a Full Blown Powerline Disturbance Analyzer

Page 36: 1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press

36

Thank you for Viewing our Meter Adapter Recorder Presentation.

For More Information Contact Your Local Representative

or Call AVO International at 800-723-2861

www.avointl.com