AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M0.1
COVER SHEET
S
R
M0.1 MECHANICAL COVER SHEET
M1.2
6/25
/201
610
0% C
DS
x
x
MECHANICAL SHEET INDEX ISSUE LOG
TITLE#
DAT
E
HVAC GENERAL NOTES
1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS. IN THE EVENT THAT ANYGENERAL NOTE CONFLICTS WITH THE WRITTEN CONSTRUCTION SPECIFICATIONS, THE
2. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL ACOMPLETE AND OPERABLE MECHANICAL SYSTEM AS INDICATED ON THE DRAWINGS,SPECIFICATIONS AND IN ACCORDANCE WITH APPLICABLE CODES.
3. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'SWRITTEN INSTRUCTIONS. THE CONTRACTOR SHALL PROVIDE ALL HANGERS AND SUPPORTS (INCOMPLIANCE WITH SEISMIC CATEGORY “C”) REQUIRED FOR A COMPLETE INSTALLATION.
4. THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE ANDGENERAL ARRANGEMENT ONLY. DO NOTE SCALE DRAWINGS.
5. COORDINATE ALL MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER CLEARANCE ANDSPATIAL RELATIONSHIPS TO OTHER EQUIPMENT AND STRUCTURAL COMPONENTS.
6. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS.COORDINATE AND PROVIDE ALL DUCT AND PIPE TRANSITIONS REQUIRED FOR FINALCONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY ALL DUCT AND PIPE DIMENSIONSPRIOR TO FABRICATION.
8. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MECHANICAL EQUIPMENT.
9. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. ALLCONTROL WIRING IN RETURN PLENUMS SHALL BE PLENUM RATED. CONTROL WIRING LOCATEDIN MECHANICAL ROOMS SHALL BE ROUTED IN RIGID CONDUIT.
10. CONTRACTOR IS RESPONSIBLE FOR THE RESTART OF ANY SYSTEMS DE-ENERGIZED TOACCOMMODATE THIS WORK.
12. PROVIDE AND INSTALL ACCESS PANELS/DOORS IN WALLS, CEILINGS AND DUCTWORK ASREQUIRED TO ACCESS/SERVICE VALVES, DUCT DETECTORS, CONTROL COMPONENTS, FIREDAMPERS AND OTHER CONCEALED MECHANICAL DEVISES.
13. ALL DUCT DIMENSIONS ARE INSIDE CLEAR UNLESS OTHERWISE NOTED. ALL DUCT DIMENSIONSSHALL BE MODIFIED AS REQUIRED TO ACCOUNT FOR DUCT INSULATION.
14. LOCATE ALL MECHANICAL EQUIPMENT TO FACILITATE UNOBSTRUCTED AIR/WATER FLOW ANDACCESS TO UNIT SERVICE PANELS, CONTROLS AND VALVES AS REQUIRED BY THEMANUFACTURER AND APPLICABLE CODES.
15. ALL AIR/HYDRONIC LEAK TESTING AND INSPECTIONS SHALL BE COMPLETED PRIOR TO THEAPPLICATION OF INSULATING MATERIALS. FAILURE TO COMPLY WITH THIS REQUIREMENT MAYRESULT IN THE REMOVAL AND REAPPLICATION OF THE INSULATION AT THE CONTRACTORS
EXPENSE.
16. LOCATE ALL TEMPERATURE, PRESSURE, FLOW MEASURING DEVICES AND COMPONENTS INACCESSIBLE LOCATIONS WITH STRAIGHT SECTIONS OF PIPE/DUCTWORK UP AND DOWN STREAMOF DEVICE AS OUTLINED BY THE EQUIPMENT MANUFACTURER.
17. TESTING, ADJUSTING AND BALANCING CONTRACTOR SHALL BE A CURRENT AND RECOGNIZEDMEMBER OF THE AABC OR NEBB AS OUTLINED IN THE CONSTRUCTION SPECIFICATIONS.
18. ALL DUCTWORK, PIPING OR EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BECOORDINATED WITH THE GENERAL CONTRACTOR. CONTRACTOR RESPONSIBLE FOR THEREPAIR/REPLACEMENT OF ANY FIREPROOFING REMOVED TO ACCOMMODATE HANGERATTACHMENT.
19. ALL NEW/MODIFIED SUPPLY DUCTWORK SHALL BE EXTERNAL INSULATED IN ACCORDANCE WITHTHE CONSTRUCTION SPECIFICATIONS.
20. CONFIRM LOCATIONS OF FIRE RATED CEILINGS, WALLS AND FLOORS. FIRE SEAL ALLPENETRATIONS WITH FIRE STOP SEALANT. DUCTWORK THAT PENETRATES FIRE PARTITIONSSHALL BE EQUIPPED WITH FIRE DAMPERS.
21. OFFSET DUCTWORK AS REQUIRED TO ACCOMMODATE THE ARCHITECTURAL REFLECTIVE CEILING PLAN.
22. NO SUPPLY DIFFUSER SHALL BE LOCATED WITHIN 36” OF ANY SMOKE DETECTOR OR AUTOMATICSPRINKLER HEAD/DEVICE.
23. ALL 45 DEGREE OR GREATER ELBOWS (INCLUDING THOSE AT DIFFUSER CONNECTIONS) SHALL BE CONSTRUCTED OF RIGID DUCTWORK.
24. ALL WORK SHALL BE PREFORMED IN ACCORDANCE WITH SITE CONSTRUCTION AND SAFETYREQUIREMENTS. NO WORK SHALL BE PERFORMED WITHOUT A VALID JOB SCHEDULE AND FIREALARM PERMITS (WHERE REQUIRED). ALL WORKERS MUST REGISTER WITH THE LOCALMAINTENANCE CONTRACTOR PRIOR TO PERFORMING ANY WORK.
25. ALL WASTE OR DISCARDED MATERIALS SHALL BE RECYCLED IN ACCORDANCE WITH SITECONSTRUCTION POLICIES. REPORT ALL RECYCLED MATERIAL QUANTITIES TO PROJECTENGINEER. WRITTEN REPORT SHALL INCLUDE MATERIAL TYPE, QUANTITIES, AND DISPOSITIONOF THE MATERIALS.
26. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE SET OF AS-BUILTDRAWINGS DETAILING ALL FIELD MODIFICATIONS TO THE DESIGN DRAWINGS. DRAWINGSSHALL INCLUDE LOCATION AND ELEVATION REFERENCED FROM FINISHED FLOOR.
MOST STRINGENT OF THE TWO SHALL RULE.
11. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLINGOVER 2000 CFM, MOUNTED IN SA DUCT (NFPA 90A, 4-4.2), AND IN RA DUCT PRIOR TOEXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNITSERVING BUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S)TO STOP UNIT FAN IF SMOKE IS DETECTED. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE.
DIFFUSER TYPEDESIGNATION
AIR QUANTITY
NOTE:RUNOUT SIZE TO
DIFFUSER IS THESAME SIZE AS THE
ROUND NECK
NOTED OTHERWISE.DIFFUSER NECK UNLESS
2410
360 CFM
B
FIRE DAMPERFD
DUCTWORKDUCTWORK - AIR TERMINALS
DUCTWORK - EQUIPMENT
SMOKE DAMPERSD
COMBINATION FIRE & SMOKE DAMPERFSD
M
SMOKE DETECTORSDT
EQUIPMENT - HVAC
EDH-xELECTRIC DUCT HEATER, WITH TAG
HVAC- AIR DISTRIBUTION TAG
AC AIR CONDITIONING UNITAD ACCESS DOORAFF ABOVE FINISHED FLOORAHU AIR HANDLING UNITAMB AMBIENTAP ACCESS PANELAS AIR STREAMATM ATMOSPHEREBD BALANCING DAMPERBDD BACK DRAFT DAMPERBHP BRAKE HORSEPOWERBLDG BUILDINGBOD BOTTOM OF DUCTBTU BRITISH THERMAL UNITBTUH BTU PER HOURCC COOLING COILCF CUBIC FEETCFM CUBIC FEET PER MINUTECLG CEILING
ABBREVIATIONS
CU,HP-x
CU,HP-x
DIFFUSER SIZE EXAMPLE:24x24 DIFFUSER WITH A
10"� NECK.
VARIABLE AIR VOLUME BOX WITH TAG,DUCT SHOWN
ROOF/CURB MOUNTED AIR HANDLINGUNIT, DUCT NOT SHOWN
INDOOR HORIZONTAL AIR HANDLINGEQUIP, DUCT SHOWN
INDOOR VERTICAL AIR HANDLINGEQUIP, DUCT NOT SHOWN
ROOF/CURB MOUNTED EXHAUST FANWITH TAG, DUCT SHOWN
INLINE SUSPENDED MOUNT EXHAUSTFAN WITH TAG, DUCT SHOWN
EF-x CEILING MOUNTED EXHAUST FANWITH TAG, DUCT SHOWN
CONDENSING UNIT ONEQUIPMENT RAILS WITH TAG
CONDENSING UNIT ON CONCRETEHOUSE KEEPING PAD WITH TAG
SIDEWALL GRILLE TAP WITHMANUAL VOLUME DAMPER, SQ
24x24
24" SIDEWALL GRILLE TAP WITHMANUAL VOLUME DAMPER, RND
MOTORIZED DAMPER
EXHAUST AIR GRILLE; EXHAUSTDUCT AND MVD IN SECTION
RETURN AIR GRILLE; RETURNDUCT AND MVD IN SECTION
SUPPLY AIR DIFFUSER; SUPPLYDUCT AND MVD IN SECTION
MVD; MANUALBALANCING/VOLUME DAMPER
HVAC LEGEND
FPS FEET PER SECONDFS FLOW SWITCHFSD COMB SMOKE FIRE DAMPERFT FOOT OR FEETG GASGAL GALLONSGALV GALVANIZEDGPM GALLONS PER MINUTEHP HORSEPOWERHR HOURHT HEIGHTHX HEAT EXCHANGERHz FREQUENCYID INSIDE DIAMETERIN INCHkW KILOWATTkWh KILOWATT HOURL LENGTHLAT LEAVING AIR TEMPERATURE
PSFG POUNDS PER SQUARE FOOTPSIG POUNDS PER SQUARE INCHQTY QUANTITYR RADIUSRA RETURN AIRREQ'D REQUIREDRF RETURN FANRH HUMIDITY, RELATIVERLA RUNNING LOAD AMPSRM ROOMSA SUPPLY AIRSD SMOKE DAMPERSF SUPPLY FANSG SPECIFIC GRAVITYSH SENSIBLE HEATSHR SENSIBLE HEAT RATIOSP STATIC PRESSURESPEC SPECIFICATIONSSQ SQUARE
MECHANICAL SPECIFICATIONS
EQUIPMENT INSTALLATION - COMMON REQUIREMENTS1. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER
BUILDING SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESSOTHERWISE INDICATED.
2. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR ORREPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OFDISCONNECTING, WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS.EXTEND GREASE FITTINGS TO ACCESSIBLE LOCATIONS.
3. INSTALL EQUIPMENT TO ALLOW RIGHT OF WAY FOR PIPING INSTALLED ATREQUIRED SLOPE.
4. DAMAGE AND TOUCHUP: REPAIR MARRED AND DAMAGED FACTORY-PAINTEDFINISHES WITH MATERIALS AND PROCEDURES TO MATCH ORIGINAL FACTORYFINISH.
DUCT HANGER AND SUPPORT INSTALLATION1. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND
FLEXIBLE," CHAPTER 4, "HANGERS AND SUPPORTS."
2. HANGER SPACING: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTIONSTANDARDS - METAL AND FLEXIBLE," TABLE 4-1, "RECTANGULAR DUCT HANGERSMINIMUM SIZE," AND TABLE 4-2, "MINIMUM HANGER SIZES FOR ROUND DUCT," FORMAXIMUM HANGER SPACING; INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHESOF EACH ELBOW AND WITHIN 48 INCHES OF EACH BRANCH INTERSECTION.
3. HANGERS EXPOSED TO VIEW: THREADED ROD AND ANGLE OR CHANNEL SUPPORTS.
4. SUPPORT VERTICAL DUCTS WITH STEEL ANGLES OR CHANNEL SECURED TO THESIDES OF THE DUCT WITH WELDS, BOLTS, SHEET METAL SCREWS, OR BLINDRIVETS; SUPPORT AT EACH FLOOR AND AT A MAXIMUM INTERVALS OF 16 FEET.
5. INSTALL UPPER ATTACHMENTS TO STRUCTURES. SELECT AND SIZE UPPERATTACHMENTS WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATEFOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED.
DUCT INSTALLATION
1. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION ANDARRANGEMENT OF DUCT SYSTEM. INDICATED DUCT LOCATIONS, CONFIGURATIONS,AND ARRANGEMENTS WERE USED TO SIZE DUCTS AND CALCULATE FRICTION LOSSFOR AIR-HANDLING EQUIPMENT SIZING AND FOR OTHER DESIGN CONSIDERATIONS.INSTALL DUCT SYSTEMS AS INDICATED UNLESS DEVIATIONS TO LAYOUT AREAPPROVED ON SHOP DRAWINGS AND COORDINATION DRAWINGS.
2. INSTALL DUCTS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTIONSTANDARDS - METAL AND FLEXIBLE" UNLESS OTHERWISE INDICATED.
3. INSTALL DUCTS WITH FEWEST POSSIBLE JOINTS.
4. INSTALL FACTORY- OR SHOP-FABRICATED FITTINGS FOR CHANGES IN DIRECTION,SIZE, AND SHAPE AND FOR BRANCH CONNECTIONS.
5. UNLESS OTHERWISE INDICATED, INSTALL DUCTS VERTICALLY AND HORIZONTALLY,AND PARALLEL AND PERPENDICULAR TO BUILDING LINES.
6. INSTALL DUCTS CLOSE TO WALLS, OVERHEAD CONSTRUCTION, COLUMNS, ANDOTHER STRUCTURAL AND PERMANENT ENCLOSURE ELEMENTS OF BUILDING.
7. INSTALL DUCTS WITH A CLEARANCE OF 1 INCH, PLUS ALLOWANCE FOR INSULATIONTHICKNESS.
8. ROUTE DUCTS TO AVOID PASSING THROUGH TRANSFORMER VAULTS ANDELECTRICAL EQUIPMENT ROOMS AND ENCLOSURES.
9. WHERE DUCTS PASS THROUGH FIRE-RATED INTERIOR PARTITIONS AND EXTERIORWALLS, INSTALL FIRE DAMPERS.
10. PROTECT DUCT INTERIORS FROM MOISTURE, CONSTRUCTION DEBRIS AND DUST,AND OTHER FOREIGN MATERIALS
11. PROTECT EXPOSED DUCTS FROM BEING DENTED, SCRATCHED, OR DAMAGED.
12. TRIM DUCT SEALANTS FLUSH WITH METAL. CREATE A SMOOTH AND UNIFORMEXPOSED BEAD. DO NOT USE TWO-PART TAPE SEALING SYSTEM.
13. GRIND WELDS TO PROVIDE SMOOTH SURFACE FREE OF BURRS, SHARP EDGES, ANDWELD SPLATTER. WHEN WELDING STAINLESS STEEL WITH A NO. 3 OR 4 FINISH,GRIND THE WELDS FLUSH, POLISH THE EXPOSED WELDS, AND TREAT THE WELDSTO REMOVE DISCOLORATION CAUSED BY WELDING.
14. MAINTAIN CONSISTENCY, SYMMETRY, AND UNIFORMITY IN THE ARRANGEMENT ANDFABRICATION OF FITTINGS, HANGERS AND SUPPORTS, DUCT ACCESSORIES, ANDAIR OUTLETS.
15. REPAIR OR REPLACE DAMAGED SECTIONS AND FINISHED WORK THAT DOES NOTCOMPLY WITH THESE REQUIREMENTS.
16. SEAL DUCTS TO THE FOLLOWING SEAL CLASSES ACCORDING TO SMACNA'S "HVACDUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE":
• COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METALAND FLEXIBLE."
• OUTDOOR, SUPPLY-AIR DUCTS: SEAL CLASS A.• OUTDOOR, EXHAUST DUCTS: SEAL CLASS C.• OUTDOOR, RETURN-AIR DUCTS: SEAL CLASS C.• UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH
WG AND LOWER: SEAL CLASS B.• UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER
THAN 2-INCH WG: SEAL CLASS A.• UNCONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS C.• UNCONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS B.• CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH WG
AND LOWER: SEAL CLASS C.• CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER
THAN 2-INCH WG: SEAL CLASS B.• CONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS B.• CONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS C.
17. THE INSTALLATION OF ALL INSULATION SHALL BE PERFORMED BY AN EXPERIENCEDCRAFTSMAN IN A NEAT WORKMANSHIP-LIKE MANNER AND SHALL BE INACCORDANCE WITH THE MANUFACTURER'S WRITTEN PUBLISHEDRECOMMENDATIONS FOR SERVICE INTENDED.
18. CONCEALED INDOOR SUPPLY, RETURN & OUTDOOR AIR DUCTS SHALL BE INSULATEDWITH A MINERAL-FIBER BLANKET, 2 INCHES THICK, 1.5-LB/CU. FT. NOMINALDENSITY.
19. EXPOSED INDOOR SUPPLY & RETURN DUCTS SHALL BE DOUBLE WALL DUCT OFSUFFICIENT CONSTRUCTION TO COMPLY WITH ENERGY CODE ANDASHRAE/IESNA 90.1.
20. EXPOSED OUTDOOR SUPPLY & EXHAUST AIR DUCTS SHALL BE INSULATED WITH AMINERAL-FIBERBOARD, 3 INCHES THICK, 3-LB/CU. FT. NOMINAL DENSITY. INSTALLJACKET OVER INSULATION MATERIAL. FOR INSULATION WITH FACTORY-APPLIEDJACKET, INSTALL THE FIELD-APPLIED JACKET OVER THE FACTORY-APPLIED JACKET.DUCTS AND PLENUMS, EXPOSED, UP TO 48 INCHES IN DIAMETER OR WITH FLATSURFACES UP TO 72 INCHES: ALUMINUM, SMOOTH MINIMUM 0.020 INCHES THICK.
21. ALL SUPPLY, RETURN & OUTDOOR AIR DUCTS ROUTED IN UNCONDITIONED SPACESHALL HAVE MINIMUM R11 INSULATION. ALL OTHER INSULATION SHALL BE PERENERGY CODE UNLESS OTHERWISE NOTED.
METAL DUCT1. DUCT CONSTRUCTION, INCLUDING SHEET METAL THICKNESSES, SEAM AND JOINT
CONSTRUCTION, REINFORCEMENTS, AND HANGERS AND SUPPORTS, SHALL COMPLYWITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE"AND PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED IN "DUCTSCHEDULE" ARTICLE.
2. STRUCTURAL PERFORMANCE: DUCT HANGERS AND SUPPORTS SHALL WITHSTANDTHE EFFECTS OF GRAVITY LOADS AND STRESSES WITHIN LIMITS AND UNDERCONDITIONS DESCRIBED IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE".
3. AIRSTREAM SURFACES: SURFACES IN CONTACT WITH THE AIRSTREAM SHALLCOMPLY WITH REQUIREMENTS IN ASHRAE 62.1-2004.
REFRIGERANT PIPING INSTALLATIONA. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND
ARRANGEMENT OF PIPING SYSTEMS; INDICATED LOCATIONS AND ARRANGEMENTSWERE USED TO SIZE PIPE AND CALCULATE FRICTION LOSS, EXPANSION, PUMPSIZING, AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS INDICATEDUNLESS DEVIATIONS TO LAYOUT ARE APPROVED ON SHOP DRAWINGS.
B. INSTALL REFRIGERANT PIPING ACCORDING TO ASHRAE 15.
C. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED ANDEXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS.
D. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS ANDSERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONALRUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE.
E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FORCEILING PANEL REMOVAL.
F. INSTALL PIPING ADJACENT TO MACHINES TO ALLOW SERVICE AND MAINTENANCE.
G. INSTALL PIPING FREE OF SAGS AND BENDS.
H. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS.
I. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATERTHAN SYSTEM OPERATING PRESSURE.
J. INSTALL PIPING AS SHORT AND DIRECT AS POSSIBLE, WITH A MINIMUM NUMBER OFJOINTS, ELBOWS, AND FITTINGS.
K. ARRANGE PIPING TO ALLOW INSPECTION AND SERVICE OF REFRIGERATIONEQUIPMENT. INSTALL VALVES AND SPECIALTIES IN ACCESSIBLE LOCATIONS TOALLOW FOR SERVICE AND INSPECTION. INSTALL ACCESS DOORS OR PANELS AS IFVALVES OR EQUIPMENT REQUIRING MAINTENANCE IS CONCEALED BEHIND FINISHEDSURFACES.
L. INSTALL REFRIGERANT PIPING IN PROTECTIVE CONDUIT WHERE INSTALLEDBELOWGROUND.
M. INSTALL REFRIGERANT PIPING IN RIGID OR FLEXIBLE CONDUIT IN LOCATIONSWHERE EXPOSED TO MECHANICAL INJURY.
N. SLOPE REFRIGERANT PIPING AS FOLLOWS:
1. INSTALL HORIZONTAL HOT-GAS DISCHARGE PIPING WITH A UNIFORM SLOPEDOWNWARD AWAY FROM COMPRESSOR.
2. INSTALL HORIZONTAL SUCTION LINES WITH A UNIFORM SLOPE DOWNWARD TOCOMPRESSOR.
3. INSTALL TRAPS AND DOUBLE RISERS TO ENTRAIN OIL IN VERTICAL RUNS.
4. LIQUID LINES MAY BE INSTALLED LEVEL.
O. WHEN BRAZING OR SOLDERING, REMOVE SOLENOID-VALVE COILS AND SIGHTGLASSES; ALSO REMOVE VALVE STEMS, SEATS, AND PACKING, AND ACCESSIBLEINTERNAL PARTS OF REFRIGERANT SPECIALTIES. DO NOT APPLY HEAT NEAREXPANSION-VALVE BULB.
P. INSTALL PIPING WITH ADEQUATE CLEARANCE BETWEEN PIPE AND ADJACENT WALLSAND HANGERS OR BETWEEN PIPES FOR INSULATION INSTALLATION.
Q. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS.
R. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS ANDSLABS.
S. INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, ANDFLOORS.
T. PROVIDE UV PROTECTIVE COATING/COVERING ON ALL ELECTROMETRIC PIPEINSULATION WHERE EXPOSED TO THE OUTDOORS.
REFRIGERANT PIPE HANGERS AND SUPPORTSPIPING HANGERS AND SUPPORTS MUST ACCOMMODATE EXPANSION AND CONTRACTION,VIBRATION, DEAD LOAD OF PIPING AND ITS CONTENTS, AND SEISMIC-BRACINGREQUIREMENTS.
A. HANGER, SUPPORT, AND ANCHOR PRODUCTS ARE SPECIFIED IN SECTION 230529"HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT."
B. INSTALL THE FOLLOWING PIPE ATTACHMENTS:
1. ADJUSTABLE STEEL CLEVIS HANGERS FOR INDIVIDUAL HORIZONTAL RUNS LESSTHAN 20 FEET LONG.
2. ROLLER HANGERS AND SPRING HANGERS FOR INDIVIDUAL HORIZONTAL RUNS 20FEET OR LONGER.
3. PIPE ROLLER: MSS SP-58, TYPE 44 FOR MULTIPLE HORIZONTAL PIPING 20 FEETOR LONGER, SUPPORTED ON A TRAPEZE.
4. SPRING HANGERS TO SUPPORT VERTICAL RUNS.
5. COPPER-CLAD HANGERS AND SUPPORTS FOR HANGERS AND SUPPORTS INDIRECT CONTACT WITH COPPER PIPE.
C. INSTALL HANGERS FOR COPPER TUBING WITH THE FOLLOWING MAXIMUM SPACINGAND MINIMUM ROD SIZES:
VERIFY ACTUAL SUPPORTED LOADS FOR HANGER SIZES AND SPACING. CONSULTSTRUCTURAL ENGINEER. SPACING AND SIZES IN SUBPARAGRAPHS BELOW ARE FROM THE2000 ASHRAE HANDBOOK - "HVAC SYSTEMS AND EQUIPMENT."
1. NPS 1/2: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH.
2. NPS 5/8: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH.
3. NPS 1: MAXIMUM SPAN, 72 INCHES; MINIMUM ROD SIZE, 1/4 INCH.
4. NPS 1-1/4: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH.
5. NPS 1-1/2: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH.
6. SUPPORT MULTIFLOOR VERTICAL RUNS AT LEAST AT EACH FLOOR.
REFRIGERANT PIPE FIELD QUALITY CONTROLA. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS.
B. TESTS AND INSPECTIONS:
1. COMPLY WITH ASME B31.5, CHAPTER VI.
2. TEST REFRIGERANT PIPING AND SPECIALTIES. ISOLATE COMPRESSOR,CONDENSER, EVAPORATOR, AND SAFETY DEVICES FROM TEST PRESSURE IF THEYARE NOT RATED ABOVE THE TEST PRESSURE.
3. TEST HIGH- AND LOW-PRESSURE SIDE PIPING OF EACH SYSTEM SEPARATELY ATNOT LESS THAN THE PRESSURES INDICATED IN PART 1 "PERFORMANCEREQUIREMENTS" ARTICLE.
a. FILL SYSTEM WITH NITROGEN TO THE REQUIRED TEST PRESSURE.
b. SYSTEM SHALL MAINTAIN TEST PRESSURE AT THE MANIFOLD GAGETHROUGHOUT DURATION OF TEST.
c. TEST JOINTS AND FITTINGS WITH ELECTRONIC LEAK DETECTOR OR BYBRUSHING A SMALL AMOUNT OF SOAP AND GLYCERIN SOLUTION OVERJOINTS.
d. REMAKE LEAKING JOINTS USING NEW MATERIALS, AND RETEST UNTILSATISFACTORY RESULTS ARE ACHIEVED.
REFRIGERANT SYSTEM ADJUSTINGA. ADJUST THERMOSTATIC EXPANSION VALVE TO OBTAIN PROPER EVAPORATOR
SUPERHEAT.
B. ADJUST HIGH- AND LOW-PRESSURE SWITCH SETTINGS TO AVOID SHORT CYCLING INRESPONSE TO FLUCTUATING SUCTION PRESSURE.
C. ADJUST SET-POINT TEMPERATURE OF AIR-CONDITIONING OR CHILLED-WATERCONTROLLERS TO THE SYSTEM DESIGN TEMPERATURE.
D. PERFORM THE FOLLOWING ADJUSTMENTS BEFORE OPERATING THE REFRIGERATIONSYSTEM, ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS:
1. OPEN SHUTOFF VALVES IN CONDENSER WATER CIRCUIT.
2. VERIFY THAT COMPRESSOR OIL LEVEL IS CORRECT.
3. OPEN COMPRESSOR SUCTION AND DISCHARGE VALVES.
4. OPEN REFRIGERANT VALVES EXCEPT BYPASS VALVES THAT ARE USED FOR OTHERPURPOSES.
5. CHECK OPEN COMPRESSOR-MOTOR ALIGNMENT AND VERIFY LUBRICATION FORMOTORS AND BEARINGS.
E. REPLACE CORE OF REPLACEABLE FILTER DRYER AFTER SYSTEM HAS BEEN ADJUSTEDAND AFTER DESIGN FLOW RATES AND PRESSURES ARE ESTABLISHED.
REFRIGERANT SYSTEM CHARGINGA. CHARGE SYSTEM USING THE FOLLOWING PROCEDURES:
1. INSTALL CORE IN FILTER DRYERS AFTER LEAK TEST BUT BEFORE EVACUATION.
2. EVACUATE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO 500MICROMETERS. IF VACUUM HOLDS FOR 12 HOURS, SYSTEM IS READY FORCHARGING.
3. BREAK VACUUM WITH REFRIGERANT GAS, ALLOWING PRESSURE TO BUILD UP TO2 PSIG.
4. CHARGE SYSTEM WITH A NEW FILTER-DRYER CORE IN CHARGING LINE.
REFRIGERANT PIPE JOINT CONSTRUCTIONA. SOLDERED JOINTS: CONSTRUCT JOINTS ACCORDING TO ASTM B 828 OR CDA'S
"COPPER TUBE HANDBOOK."
B. BRAZED JOINTS: CONSTRUCT JOINTS ACCORDING TO AWS'S "BRAZING HANDBOOK,"CHAPTER "PIPE AND TUBE."
1. USE TYPE BCUP, COPPER-PHOSPHORUS ALLOY FOR JOINING COPPER SOCKETFITTINGS WITH COPPER PIPE.
2. USE TYPE BAG, CADMIUM-FREE SILVER ALLOY FOR JOINING COPPER WITHBRONZE OR STEEL.
COL COLUMN CONC CONCRETECRAC COMPUTER ROOM UNITCU CONDENSING UNITDB DRY BULBDC DRY COOLERDDC DIRECT DIGITAL CONTROLDIA DIAMETERDP DIFFERENTIAL PRESSUREDX DIRECT EXPANSIONEA EACH OR EXHAUST AIREAT ENTERING AIR TEMPERATUREEF EXHAUST FANEWT ENTERING WATER TEMPERATUREEXP EXPANSIONF FAHRENHEITFA FACE AREAFD FIRE DAMPERFP FAN POWEREDFPM FEET PER MINUTE
LF LINEAR FEETLH LATENT HEATLVR LOUVERLWT LEAVING WATER TEMPERATUREMBU THOUSAND BTUHMFR MANUFACTURERMIN MINIMUMMOD MOTOR OPERATED DAMPERMVD MANUAL VOLUME DAMPERN/A NOT APPLICABLENC NOISE CRITERIANOM NOMINALNTS NOT TO SCALEOA OUTSIDE AIROD OUTSIDE DIAMETERP PUMPPH PHASE (ELECTRICAL)PLBG PLUMBING
TOD TOP OF DUCTTYP TYPICALU HEAT TRANSFER COEFFICIENTUCD UNDERCUT DOORUH UNIT HEATERV VOLTSVAV VARIABLE AIR VOLUMEVFD VARIABLE FREQUENCY DRIVEVOL VOLUMEW WATTWB WET BULBWC WATER COLUMNWPD WATER PRESSURE DROP
BDD BACK DRAFT DAMPER WITHAIR FLOW INDICATION
M1.1 1ST FLOOR - MECHANICAL PLAN x
27. EACH BRANCH DUCT SERVING A DIFFUSER SHALL HAVE A MANUAL BALANCING DAMPER INSTALLEDAT MAIN DUCT TAKE-OFF REGARDLESS OF DRAWING OMISSION.
NEW FLEXIBLE DUCTWORK
N E
EXISTING DUCTWORK TO NEWDUCTWORK CONNECTION
24x12
24x12
24x12
SQUARE DUCT TAKE OFF, TOP
SQUARE DUCT TAKE OFF, BOTTOM
SQUARE DUCT TAKE OFF, TOP
SQUARE DUCT TAKE OFF, BOTTOM
RND ELBOW 45°, RADIUS24"
SQ ELBOW 45°, RADIUS24x24
SQ ELBOW 45°, MITERED24x24
SQ TO RND CONCENTRICTRANSITION IN DROP
SQ TO RND CONCENTRICTRANSITION IN RISE
SQ TO SQ ECCENTRIC TRANSITION
SQ TO SQ CONCENTRIC TRANSITION
SQ TO RND ECCENTRIC TRANSITION
SQ TO RND CONCENTRICTRANSITION
24x12
24x12
24x12
24"
24"
RND ELBOW 45°, RADIUS24"
RND ELBOW 90°, MITERED
RND ELBOW 90°, RADIUS
SQUARE ELBOW, NOTURNING VANES
RND DUCT ELEVATION CHANGE, UP
RND DUCT ELEVATION CHANGE,DOWN
NEW DUCTWORK WITH LINER
ROUND DUCT TAKE OFF
24"DUCTWORK DIMENSION LABEL(24" DIAMETER)
24x12DUCTWORK DIMENSION LABEL(24" WIDTH x 12" HEIGHT)
SQUARE DUCT TAKE OFF, SIDE
SQ DUCT ELEVATION CHANGE, 90°UP
SQ DUCT ELEVATION CHANGE, 90°DOWN
NEW RIGID DUCTWORK
EXISTING DUCTWORK TO BEDEMOLISHED
EXISTING DUCTWORK TO REMAIN
SQUARE ELBOW WITH DOUBLETHICKNESS TURNING VANES
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
M1.3 x
M1.4 x
M1.5 ROOF - MECHANICAL PLAN
M2.1 MECHANICAL SCHEDULES 1 OF 2
M2.2 MECHANICAL SCHEDULES 2 OF 2
2ND FLOOR - MECHANICAL PLAN
3RD FLOOR - MECHANICAL PLAN
4TH FLOOR - MECHANICAL PLAN
x
x
x
M3.1 MECHANICAL DETAILS 1 OF 2 x
xM3.2 MECHANICAL DETAILS 2 OF 2
Ø
M1.5 MECHANICAL ENLARGEMENT PLANS x
D W
RE
F.D
W
UP
RD4RD3 RD5 RD6
RD7
RD1 RD2RD8 RD9
CL
A0.7
A.07
A.06
A.05
12.5 11.8
VAN
~4'-6
"
DEPT
H
~4'-0
"D
EP
TH
5'-0"
DEPT
H
3'-6
"D
EP
TH
POOL
PTAC-11
PTAC-11
PTAC-11
PTAC-1
1
S
CFM2502410 A
(TYPICAL OF 8)
36x42 B
CCFM165
48" x 2 Slot
(TYPICAL OF 6)10"∅
CCFM165
48" x 2 Slot
(TYPICAL OF 3)10"∅
CCFM165
48" x 2 Slot
(TYPICAL OF 3)10"∅
12x12 12x12
32x2
0
CFM2002408 A
CFM1502408 ACFM 50
2406 A CFM1502408 A
CFM2502410 A24x12 D
24x12 D
12x24 D
16x1
2
12x12
CFM2502410 A
CFM1502408 A
CFM 502406 A
CFM1802408 A
CFM4002410 A
CFM4102410 A
12x12
24x24 D
CFM19524x12 D
12x24 D
CFM4102410 A
CCFM250
48" x 2 Slot10"∅
CCFM150
48" x 2 Slot10"∅
CFM1002406 A
CFM1502408 A
CCFM225
48" x 2 Slot10"∅
CCFM225
48" x 2 Slot10"∅
CCFM225
48" x 2 Slot10"∅
CCFM225
48" x 2 Slot10"∅
(TYPICAL OF 3)
10"∅
CCFM250
48" x 2 Slot10"∅
(TYPICAL OF 4)
CCFM250
48" x 2 Slot10"∅
(TYPICAL OF 4)
18x1
2
24x24 D
CCFM250
48" x 2 Slot10"∅
(TYPICAL OF 8)
24x24 D
14"∅CFM380
2412 A
(TYPICAL OF 5)
PTAC-11
PTAC-11
PTAC-1
1
PTAC-1
1
PTAC-11
PTAC-11
PTAC-1
1
CFM50024x24 D
CFM17524x12 D
CFM 7524x12 D
18x10
CFM 7524x12 D
CFM19524x24 D
CFM1502408 A
CFM19524x24 D
10"∅
8"∅
CFM1552408 A
375
10x10
10"∅
(TYPICAL OF 2)
10"∅
6"∅
10"∅
10"∅
10x8
6"∅
6"∅
6"∅
6"∅
6"∅
16x10
6"∅
8"∅
CFM1552408 A
8"∅
6"∅
6"∅
10"∅10"∅
8"∅
8"∅
S
S
S
S
EWH-17
EWH-27
10"∅
M
5
4
HP-8HP-7HP-6HP-5HP-4
HP-3HP-2HP-1
AHU-1 AHU-2
AHU-3 3
AHU-4 3
3
AHU-8
11
11
11 11
11
1111
11
8
9
EUH-110
S
S
S
FD
FD
FD
FD
FD
FD
FD FD FDFDFD
FD FD
FD
FD
FD
FD
FD
FDFD
FD
FD
FD
FD FD FD
FD
FSD FSD
FD FD
FDFD
FD
FD
FD
FD
FD
EWH-5
13
14
6"AFF
24x12 D(TYPICAL OF 2)
10"∅
8"∅C.O.
C.O.
C.O
.
C.O.
C.O.
16
18
19
20
20
20EDH-1
21
CFM1002406 A
11
11
1111 11
11
11
11
11
11
24x12 D(TYPICAL OF 2)
10"∅ 10"∅FD FD FD FD
AHU-7
AHU-6
AHU-5
3
3
12x10
FSD
FSDFSD
FSD
13
M1.1
1SCALE: 1/8"= 1'-0"
MECHANICAL - HVAC - 1ST FLOORAEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.1
HVAC1ST FLOOR
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.
HVAC SHEET NOTES - UNREFERENCED
1
HVAC SHEET NOTES - REFERENCED
2
3
4
5
MOUNT CONDENSING UNIT AT GRADE ON 6" THICK RE-INFORCED CONCRETE PAD• PAD EXTENDS 6" ON EVERY SIDE OF UNIT.• MAINTAIN 36" CLEARANCE TO ELECTRICAL ACCESS PANELS.• ROUTE REFRIGERANT PIPING FROM CONDENSING UNIT UP IN EXTERIOR WALL (OR CHASE) AND TO CORRESPONDING A/C UNIT.• MINIMIZE PIPING EXPOSED ON EXTERIOR.• SEAL ALL PENETRATIONS TO EXTERIOR WEATHER TIGHT.• MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES BETWEEN UNITS.
FLOOR MOUNTED VERTICAL AC UNIT• MOUNT A/C UNIT ON 1/4" NEOPRENE ISOLATOR ON 24" HIGH RETURN AIR PLENUM AND CONFIGURE FOR BOTTOM RETURN.• CONNECT SA DUCT WITH FLEXIBLE CONNECTION.• ROUTE CONDENSATE DRAIN LINE TO SPILL IN FLOOR DRAIN SHOWN ON PLUMBING DRAWINGS• CONFIGURE UNIT IN SPACE TO ALLOW MFG SERVICE CLEARANCES & FILTER ACCESS.
DRYER VENTILATION SYSTEM• EXTEND 10" ROUND DRYER VENT FROM COMMERCIAL-TYPE CLOTHES DRYER TO COMMON LOUVER IN EXTERIOR WALL.• WRAP VENT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE BARRIER DUCT WRAP OR LIKE MATERIAL TO WITHSTAND
DRYER VENT HEAT.• DRYER VENTS TERMINATE AT 42x24 WALL LOUVER. SLEEVE AND SEAL PENETRATION WEATHER TIGHT.• LOUVER SIZED TO PROVIDE A FREE AREA OF 3.30ft2 TO ALLOW 2760CFM EXHAUST AT 850FPM. (920CFM PER DRYER x 3)• LOUVER BASED ON MANUFACTURER: UNITED ENERTECH MODEL: FL-D-4• VENTS TO BE SINGLE WALL GALVANIZED STEEL MIN. 0.0195 INCHES THICK.• INSTALL ESCUTCHEON PLATE AT PENETRATION OF ROOM SURFACES.• REVIEW MANUFACTURER'S VENTING REQUIREMENTS BEFORE COMMENCING WORK.• DRYER VENTS ARE TO HAVE SMOOTH INTERIOR SURFACES.• RIVET ALL CONNECTIONS & MAINTAIN CODE REQUIRED CLEARANCES.
PROVIDE ONE (1) 36x12 WALL LOUVER TO PROVIDE COMBUSTION/VENTILATION AIR FOR DRYERS.• MOUNT LOUVER 6" BELOW CEILING/ROOF STRUCTURE.• SLEEVE BUILDING PENETRATION AND SEAL WEATHER TIGHT.• LOUVER DESIGN BASED ON UNITED ENERTECH MODEL FL-D-4. PROVIDE MOTORIZED DAMPER INTERLOCKED WITH DRYERS FOR
SIMULTANEOUS OPERATION.• DAMPER SHALL ACTUATE FULLY OPEN UPON A MINIMUM OF ONE DRYER ACTIVATION.• EXACT LOUVER LOCATION IS TO BE COORDINATED WITH ARCHITECTURAL.• LOUVER IS SIZED TO ALLOW 135.0 SQinch (0.94 SQft) OF FREE AREA FOR LOUVER AS REQUIRED BY INT FUEL GAS CODE (304.6.2)
(1 SQinch OF FREE AREA PER 3,000 btuh OF COMBUSTION AT A TOTAL INPUT LOAD OF 405,000 btuh) (135,000 btuh PER DRYER X 3)• PROVIDE COMPLETE WITH BUG SCREEN.
PROVIDE SERVICEABLE LINT TRAP IN DRYER EXHAUST DUCT RISE. (TYPICAL OF 3)• LINT TRAP TO BE MAKE: LINT LASSO MODEL: LLA• PROVIDE COMPLETE WITH OVER PRESSURE MONITORING STATION TO INSURE
PROPER DRYER WORKING ORDER.
MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON A DETECTION OF SPACE TEMPERATURE TO BE DETERMINED BY OWNER.
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 10"∅ SUPPLY• 10"∅ EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 30x12 SUPPLY• 24x14 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
ELECTRIC UNIT HEATER• SUSPEND HEATER FROM STRUCTURE UTILIZING VIBRATION ISOLATION KIT.• MOUNT THERMOSTAT/CONTROLER IN ROOM AS SHOWN.• HEATER SHALL ENERGIZE UPON 45° SPACE DETECTION.
CABLE CONTROLLED BALANCING DAMPER (SEE DETAIL)• INSTALL PER MANUFACTURERS SUGGESTED GUIDELINES• TYPICAL OF ANY APPLICATION WHERE ACCESS TO MANUAL DAMPER IS RESTRICTED OR UNDESIRED.
2
MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE
HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.
6
7
8
9
10
11
SUSPEND EXHAUST FAN FROM STRUCTURE UTILIZING VIBRATION ISOLATION HANGERS.• ROUTE DUCT TO LOUVER/BRICK VENT IN EXTERIOR WALL.
12x12 LOUVER IN EXTERIOR WALL TO PROVIDE VENTILATION AIR INTAKE, SLEEVE AND SEAL BUILDINGPENETRATION WEATHER TIGHT.• LOUVER IS TO BE UNITED ENERTECH MODEL FL-D-4 SIZED TO PROVIDE A FREE AREA OF 0.32sqft.
FOR 50cfm.
MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON DETECTION OF 45°F SPACE TEMPERATURE &
DE-ENERGIZE AT 55°F.
12
13
14
DRYER VENT ASSEMBLY• 4" DRYER VENT OUT TO WALL CAP.• PROVIDE BOOSTER FAN AND ASSOCIATED LINT TRAP PRIOR TO FAN AT APPROXIMATELY THIS LOCATION.• INSTALL LINT TRAP & FAN IN A MANNER TO ALLOW SERVICE/CLEAN OUT.• BOOSTER FAN TO BE MANUFACTURER: FANTECH MODEL: DBF4XL.• FAN OPERATES VIA PRESSURE SWITCH TO RUN IN SEQUENCE WITH DRYER.
15
DISHWASHER HOOD ASSEMBLY• AT DISHWASHER EXHAUST HOOD (BY OTHERS), EXTEND 12"∅ DUCT FROM HOOD TO
ROOF MOUNTED EXHAUST FAN ON CURB, ROOF CURB TO OFFSET ROOF SLOPE.
AT RANGE HOOD ASSEMBLY, PROVIDED BY OTHERS• CONNECT 29x10 EXHAUST DUCT TO HOOD EXHAUST OPENING (3070 CFM).• CONNECT 3 - 28"x12" DUCTS TO HOOD MAKE UP AIR OPENINGS (2456 CFM TOTAL). PROVIDE MANUAL
VOLUME DAMPER IN EACH DROP FOR PROPER SYSTEM BALANCING.• EXTEND MAKEUP AIR DUCT TO CURB MOUNTED SUPPLY FAN ON ROOF, CURB TO OFFSET ROOF SLOPE.• EXTEND 40x12 EXHAUST DUCT TO ROOF MOUNTED EXHAUST FAN, CURB TO OFFSET ROOF SLOPE.• ALL HOOD DUCTWORK TO BE CONSTRUCTED OF STEEL NOT LESS THAN 0.030 INCH NO.22 GAGE IN
THICKNESS, STAINLESS STEEL NOT LESS THAN 0.024 INCH NO. 24 GAGE IN THICKNESS, COPPER SHEETSWEIGHING NOT LESS THAN 24 OUNCES PER SQUARE FOOT OR OF OTHER APPROVES MATERIAL GAGE.WELD ALL DUCT LIQUID TIGHT. WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUALTO 3M FIRE BARRIER DUCT WRAP.
• INTERLOCK KSF-1 AND KEF-1 WITH HOOD FOR SIMULTANEOUS OPERATION WHILE HOOD IS ENERGIZED.
• EXHAUST DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.
GREASE CLEAN OUT DOORS (TYPICAL)• PROVIDE IN EXHAUST DUCT, SPACE NO MORE THAN 20 FEET APART AND NO MORE THAN
10 FEET FROM CHANGES IN DIRECTION.• CLEAN OUT DOOR SHALL NOT BE CLOSER THAN 1 INCH FROM THE EDGES OF DUCT AND BE
CONSTRUCTED OF MATERIALS TO MATCH GREASE DUCT IN GAGE AND TYPE.• DOOR GASKET AND SEALING MATERIALS SHALL BE RATED FOR NOT LESS THAN 1500°F.
EXHAUST DUCT CONTINUES TO ROOF MOUNTED EXHAUST FAN• SEE SHEET 2ND FLOOR FOR CONTINUATION.• EXHAUST DUCT FROM HOOD SHALL BE FREE OF FIRE DAMPER AS REQUIRED BY CODE.• WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE
BARRIER DUCT WRAP.• DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.
16
17
18
19
DUCT UP TO ROOF MOUNTED EQUIPMENT20
DUCT MOUNTED ELECTRIC HEATER• INSTALL IN A MANNER TO ALLOW SERVICE CLEARANCES.• HEATER SHALL ENERGIZE UPON A 40°F AIR STREAM TEMPERATURE.
21
UP
DN
UP
DN
KING
201QQ
203QQ
205KING - HEARING
207KING
209KING
211
KING
213KING
215QQ
219KING
221KING
223KING
225QQ
227
QQ - HEARING
229KING
231KING
233
202
ACC. KING
HEARING
204KING
206
KING
208
KING
210
ACC. QQ INLINE
SUITE
216
218QQ
220
KING
222
KING - HEARING
224QQ
226KING
228KING
230
217
912
ELECTRICAL
2005
LINEN
2004
KING
214
COMPUTER/
COMM ROOM
2006
ICE
2003
RD3 RD4 RD5 RD7
STAIR 1
S1STAIR 2
S2
ELEVATOR
LOBBY
2001CORRIDOR EAST
2000CORRIDOR WEST
2002CL
10.210.8
A.04
A.07
A.06
A.03
A.05
12.5
11.8
11.8
PTAC-11
PTAC-11
CFM10012x12 F
CFM15012x12 E
CFM12512x12 F
CFM15012x12 E
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-1
6
12x8
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-2
6PTAC-1
1
PTAC-11
PTAC-11
PTAC-1
1
PTAC-1
1
PTAC-11
PTAC-1
PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
FSD FSD
FSD FSD
FD FD
14x6
12x10
CD
CDCDCDCD
CDCDCDCDCDCD
CD
CD CD
2
3
5
FSD
FSD
FSD
FSD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FDFD FDFDFD
FDFD
FD FD
HW-CU-1 HW-CU-2
18x12
KEF-1DEF-1
KSF-1
1 PTAC-1 1
PTAC-11 PTAC-1 1
7
77
88
FD
CFM3002410 A
CFM2702410 A
M1.2
1SCALE: 1/8"= 1'-0"
MECHANICAL - HVAC - 2ND FLOOR
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.2
HVAC2ND FLOOR
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.
HVAC SHEET NOTES - UNREFERENCED
1
HVAC SHEET NOTES - REFERENCED
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x20 SUPPLY• 22x20 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE
HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.
2
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x12 SUPPLY• 24x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
3
DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.
4
EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)
5
6 INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.
7 CURB MOUNTED FAN• INSTALL FAN LEVEL ON ROOF CURB, CURB IS TO OFFSET ANY ROOF SLOPE.• INTERLOCK FAN WITH ASSOCIATED KITCHEN HOOD FOR SIMULTANEOUS OPERATION.
CONDENSING UNITS• MOUNT UNITS LEVEL ON METAL EQUIPMENT RAILS.• RAILS ARE TO BE CONSTRUCTED OF A MATERIAL TO WITHSTAND WEATHERING/RUSTING• ROUTE REFRIGERANT LINES TO CORRESPONDING INDOOR UNIT UTILIZING THE SHORTEST RUN POSSIBLE WHILE
MAINTAINING PROPER MECHANICAL STANDARDS.• SUPPORT REFRIGERANT LINES OFF ROOF WITH POLYMER BLOCKS.• REFRIGERANT LINES ARE TO PENETRATE BUILDING THROUGH CURBED PITCH POCKET SEALED WEATHER TIGHT.
8
DN UP DNUP
KING
333KING
331QQ - HEARING
329 QQ
327
KING
325KING
323KING
321
319ACC. QQ
317
KING
315KING - WIDE
313
KING
311KING
309KING - HEARING
307QQ
305QQ
303
KING
301
QQ - HEARING
302ACC. KING
304
KING
306KING
308KING
310KING
314
ACC. QQ INLINE
SUITE
316
318
320
KING
322KING - HEARING
324
326KING
328KING
330
ELECTRICAL
3005
LINEN
3004
COMPUTER/
COMM ROOM
3006
ICE
3003
ELEVATOR
LOBBY
3001COORIDOR EAST
3000CORRIDOR WEST
3002
STAIR 2
S2
STAIR 1
S1
KING
314
TYP. TYP.
TYP.
TYP.
EWH-47
EWH-37
PTAC-11
PTAC-1
1
CFM10012x12 F
CFM15012x12 E
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-3
6
12x8
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-4
6PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-11
PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-1
1PTAC-1
1PTAC-1
1
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
FSD FSD
FSD FSD
FD FD
14x6
12x10
CD
CDCDCD
CDCD
CD CD
2
3
5
FSD
FSD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD FDFDFD
FDFD
FD FD
CFM15012x12 E
CFM12512x12 F
CD
FSD
FSD FD
18x12
FD
CFM3002410 A
CFM2702410 A
M1.3
1SCALE: 1/8"= 1'-0"
MECHANICAL - HVAC - 3RD FLOOR
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.3
HVAC3RD FLOOR
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.
HVAC SHEET NOTES - UNREFERENCED
1
HVAC SHEET NOTES - REFERENCED
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x24 SUPPLY• 24x24 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE
HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.
2
3
DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.
4
EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)
5
6
7
INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.
MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON A DETECTION OF SPACE TEMPERATURE TO BE DETERMINED BY OWNER.
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 36x12 SUPPLY• 36x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
DNDN
KING
433KING
431
429QQ
427KING
425KING
423KING
421QQ
419QQ
417
KING
415KING
413
KING
411KING
409KING
407QQ
405QQ
403KING
401
QQ - HEARING
402QQ
404KING
406KING
408
KING
410
QQ INLINE SUITE
- HEARING
416
418QQ
420KING
422KING
424QQ
426KING
428KING
430
ELECTRICAL
4005
LINEN
4004
COMPUTER/
COMM ROOM
4006
ELEVATOR
LOBBY
4001 CORRIDOR EAST
4000
ICE
4003
CORRIDOR WEST
4002
STAIR 2
S2
STAIR 1
S1
KING
414
TYP. TYP.
TYP.
TYP.
A0.7
ROOF LADDER
PTAC-11
PTAC-11
CFM3002410 A
CFM15012x12 E
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-5
6
CFM2702410 A
12x8
CFM 5012x12 E
TYPICAL OF ALLGUEST ROOMS
CFM 5512x12 F
TYPICAL OF ALL GUESTRESTROOM EXHAUST
HWFC-6
6PTAC-1
1
PTAC-11
PTAC-11
PTAC-1
1
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-1
1
PTAC-1
1
PTAC-1
1
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
PTAC-11
FSD FSD
FSD FSD
FD FD
14x6
12x10
CD
CDCDCD
CD
CD
CD CD
2
3
5
FSD
FSD
FD
FD
FD
FD
FD FD
FD
FD
FDFD FDFDFD
FDFD
FD FD
CFM15012x12 E
CFM12512x12 F
CD
FSD
FSD FD
18x12
FD
M1.4
1SCALE: 1/8"= 1'-0"
MECHANICAL - HVAC - 4TH FLOOR
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.4
HVAC4TH FLOOR
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.
HVAC SHEET NOTES - UNREFERENCED
1
HVAC SHEET NOTES - REFERENCED
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 26x26 SUPPLY• 26x26 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE
HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.
2
OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 42x12 SUPPLY• 40x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.
3
DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.
4
EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)
5
6 INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.
RD1 RD2 RD3 RD4 RD5 RD6 RD7 RD8 RD9
OF1 OF2 OF3 OF4 OF5 OF6 OF7 OF8 OF9
M MMAU-2
2
HW-CU-3
HW-CU-4
HW-CU-5
HW-CU-6
28x2
0
SDT
SDT
SDT
SDT
M1.5
1SCALE: 1/8"= 1'-0"
MECHANICAL - HVAC - ROOF
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.5
HVACROOF
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.
HVAC SHEET NOTES - UNREFERENCED
1
HVAC SHEET NOTES - REFERENCED
2
68x16 LOUVER WITH AT LEAST 3 SQUARE FEET OF FREE AREA FOR EACH CAR FOR ELEVATOR SHAFT RELIEF• COORDINATE LOCATION WITH ARCHITECTURAL.• MODEL BASED ON RUSKIN ELC445D.• PROVIDE LOUVERS WITH MOTORIZED DAMPERS TIED INTO THE FIRE ALARM SYSTEM.• SLEEVE AND SEAL AROUND LOUVER WEATHER TIGHT• PROVIDE COMPLETE WITH BUG SCREEN
3
4
VERTICAL SUPPLY / EXHAUST DUCTS DOWN INTO CHASE THROUGH ROOF CURB.• OFFSET/TRANSITION DUCTWORK IN CURB TO ALLOW PROPER ENTRY INTO CHASE
MOUNT MAU UNIT AS SHOWN ON FACTORY ROOF CURB (MIN. 24" HIGH).• MAINTAIN 36" CLEARANCE TO ELECTRICAL ACCESS PANELS.• SUPPLY DUCT IS TO BE SIDE DISCHARGE FROM CURB, ROUTE TO CURBED ROOF PENETRATION AS SHOWN.• EXHAUST DUCT IS TO BE SIDE DISCHARGE FROM CURB, ROUTE TO CURBED ROOF PENETRATION AS SHOWN.• ROUTE FULL SIZE CONDENSATE DRAIN TO SPILL ON ROOF. SLOPE CONDENSATE LINE 1/8" AWAY FROM UNIT.• PROVIDE CURB EXTENSION AS NEEDED TO TRANSITIONS DUCTS INTO CHASE BELOW.• INSTALL FIRE/SMOKE DETECTORS IN SUPPLY AND EXHAUST AIR STREAMS AS REQUIRED BY CODE/NFPA. DETECTORS SUPPLIED BY MECHANICAL
CONTRACTOR AND INSTALLED/WRIED BY ELECTRICAL CONTRACTOR.
CURB MOUNTED GRAVITY RELIEF ON TOP OF LINEN CHUTE• MOUNT CAP LEVEL ON ROOF CURB TO OFFSET ANY SLOPE• MAP MFG: GREENHECK MODEL: GRSR-24• PROVIDE COMPLETE WITH BUG SCREEN• 10'-0"∅ CLEARANCE TO FRESH AIR INTAKE RADIUS SHOWN
5 CONDENSING UNITS• MOUNT UNITS LEVEL ON METAL EQUIPMENT RAILS.• RAILS ARE TO BE CONSTRUCTED OF A MATERIAL TO WITHSTAND WEATHERING/RUSTING• ROUTE REFRIGERANT LINES TO CORRESPONDING INDOOR UNIT UTILIZING THE SHORTEST RUN POSSIBLE WHILE MAINTAINING PROPER
MECHANICAL STANDARDS.• SUPPORT REFRIGERANT LINES OFF ROOF WITH POLYMER BLOCKS.• REFRIGERANT LINES ARE TO PENETRATE BUILDING THROUGH CURBED PITCH POCKET SEALED WEATHER TIGHT.
6 EXPOSED EXHAUST DUCT ON ROOF.• DUCT EXITS ROOF CURB HORIZONTALLY THROUGH CUSTOM OPENING.• SUPPORT DUCT OFF ROOF WITH STEEL FRAME SPACED A MINIMUM 48" ON CENTER AND AT EACH ELBOW.• SEE DUCT SUPPORTS OFF ROOF DETAIL FOR CLARITY.• DUCT SHALL BE INSULATED WITH A MINERAL-FIBERBOARD, 3 INCHES THICK, 3-LB/CU. FT. NOMINAL DENSITY. INSTALL
WEATHER RESISTANT JACKET OVER INSULATION MATERIAL. FOR INSULATION WITH FACTORY-APPLIED JACKET, INSTALL THEFIELD-APPLIED JACKET OVER THE FACTORY-APPLIED JACKET. DUCTS AND PLENUMS, EXPOSED, UP TO 48 INCHES IN DIAMETEROR WITH FLAT SURFACES UP TO 72 INCHES: ALUMINUM, SMOOTH MINIMUM 0.020 INCHES THICK.
• DUCT ENTERS TOP OF CHASE VIA CURBED POCKET SEALED WEATHER TIGHT, TRANSITION DUCT AS REQUIRED TO MATCHDROP IN CHASE PRIOR TO CHASE PENETRATION.
RD7
36x42 B
32x2
0
26x1
2
10"∅
26x1
4
AHU-42
AHU-8
EUH-111
FD
FD
FD
FD
FD
FD
FD FD FD FD
AHU-7
AHU-6
AHU-5
3
3
3
3
14x1
0
26x12
26x12
14x12
16x12
SDT
SDT
SDT
SDT
SDT
SDT
SDT
SDT
SDT
2
SDT
4
RD4RD3
A0.7
22x14
20x20
24x24 D
22x1
4
20x20
18x1
414
x14
CFM3802412 A
(TYPICAL OF 5)
10"∅6"∅
AHU-1
FD FD FD
22x1
4
40x1
2
30x12
C.O.
C.O.
C.O.
C.O.
6
7
8
9
EDH-1
10
CFM1002406 A
FD
24x24 D
AHU-3AHU-2
14x10
10x1010"∅
FD
20x20
FD FD
24x24 D
FD
FD
14"∅
5
SDT
SDT
SDT
SDT
SDT
SDT
KEF-1DEF-1
KSF-113
C.O.
9
9
1313
S
M1.6
1SCALE: 1/4"= 1'-0"
MECHANICAL - ENLARGEMENT PLAN A
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M1.6
ENLARGEMENTPLANS
a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.
b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.
c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.
d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.
e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.
f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.
HVAC SHEET NOTES - UNREFERENCED
M1.6
2SCALE: 1/4"= 1'-0"
MECHANICAL - ENLARGEMENT PLAN
1
HVAC SHEET NOTES - REFERENCED
2
3
4
5
FLOOR MOUNTED VERTICAL AC UNIT• MOUNT A/C UNIT ON 1/4" NEOPRENE ISOLATOR ON 24" HIGH RETURN AIR PLENUM AND CONFIGURE FOR BOTTOM RETURN.• CONNECT SA DUCT WITH FLEXIBLE CONNECTION.• ROUTE CONDENSATE DRAIN LINE TO SPILL IN FLOOR DRAIN SHOWN ON PLUMBING DRAWINGS• CONFIGURE UNIT IN SPACE TO ALLOW MFG SERVICE CLEARANCES & FILTER ACCESS.• CONFIGURE UNIT FOR BOTTOM RETURN WITH TOP DISCHARGE.
ELECTRIC UNIT HEATER• SUSPEND HEATER FROM STRUCTURE UTILIZING VIBRATION ISOLATION KIT.• MOUNT THERMOSTAT/CONTROLER IN ROOM AS SHOWN.• HEATER SHALL ENERGIZE UPON 45° SPACE DETECTION.
11
12 DRYER VENT ASSEMBLY• 4" DRYER VENT OUT TO WALL CAP.• PROVIDE BOOSTER FAN AND ASSOCIATED LINT TRAP PRIOR TO FAN AT APPROXIMATELY THIS LOCATION.• INSTALL LINT TRAP & FAN IN A MANNER TO ALLOW SERVICE/CLEAN OUT.• BOOSTER FAN TO BE MANUFACTURER: FANTECH MODEL: DBF4XL.• FAN OPERATES VIA PRESSURE SWITCH TO RUN IN SEQUENCE WITH DRYER.
DISHWASHER HOOD ASSEMBLY• AT DISHWASHER EXHAUST HOOD (BY OTHERS), EXTEND 12"∅ DUCT FROM HOOD TO
ROOF MOUNTED EXHAUST FAN ON CURB, ROOF CURB TO OFFSET ROOF SLOPE.
AT RANGE HOOD ASSEMBLY, PROVIDED BY OTHERS• CONNECT 29x10 EXHAUST DUCT TO HOOD EXHAUST OPENING (3070 CFM).• CONNECT 3 - 28"x12" DUCTS TO HOOD MAKE UP AIR OPENINGS (2456 CFM TOTAL). PROVIDE MANUAL
VOLUME DAMPER IN EACH DROP FOR PROPER SYSTEM BALANCING.• EXTEND MAKEUP AIR DUCT TO CURB MOUNTED SUPPLY FAN ON ROOF, CURB TO OFFSET ROOF SLOPE.• EXTEND 40x12 EXHAUST DUCT TO ROOF MOUNTED EXHAUST FAN, CURB TO OFFSET ROOF SLOPE.• ALL HOOD DUCTWORK TO BE CONSTRUCTED OF STEEL NOT LESS THAN 0.030 INCH NO.22 GAGE IN
THICKNESS, STAINLESS STEEL NOT LESS THAN 0.024 INCH NO. 24 GAGE IN THICKNESS, COPPER SHEETSWEIGHING NOT LESS THAN 24 OUNCES PER SQUARE FOOT OR OF OTHER APPROVES MATERIAL GAGE.WELD ALL DUCT LIQUID TIGHT. WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUALTO 3M FIRE BARRIER DUCT WRAP.
• INTERLOCK KSF-1 AND KEF-1 WITH HOOD FOR SIMULTANEOUS OPERATION WHILE HOOD IS ENERGIZED.
• EXHAUST DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.
GREASE CLEAN OUT DOORS (TYPICAL)• PROVIDE IN EXHAUST DUCT, SPACE NO MORE THAN 20 FEET APART AND NO MORE THAN
10 FEET FROM CHANGES IN DIRECTION.• CLEAN OUT DOOR SHALL NOT BE CLOSER THAN 1 INCH FROM THE EDGES OF DUCT AND BE
CONSTRUCTED OF MATERIALS TO MATCH GREASE DUCT IN GAGE AND TYPE.• DOOR GASKET AND SEALING MATERIALS SHALL BE RATED FOR NOT LESS THAN 1500°F.
EXHAUST DUCT CONTINUES TO ROOF MOUNTED EXHAUST FAN• SEE SHEET 2ND FLOOR FOR CONTINUATION.• EXHAUST DUCT FROM HOOD SHALL BE FREE OF FIRE DAMPER AS REQUIRED BY CODE.• WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE
BARRIER DUCT WRAP.• DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.
DUCT UP TO ROOF MOUNTED EQUIPMENT
DUCT MOUNTED ELECTRIC HEATER• INSTALL IN A MANNER TO ALLOW SERVICE CLEARANCES.• HEATER SHALL ENERGIZE UPON A 40°F AIR STREAM TEMPERATURE.
DUCT MOUNTED SMOKE DETECTOR• PROVIDE DUCT MOUNTED SMOKE DETECTOR IN RETURN DUCT PRIOR TO MIXING WITH OUTDOOR AIR.• PROVIDE DUCT MOUNTED SMOKE DETECTOR IN SUPPLY PRIOR TO ANY TAKE OFFS
PROVIDE BALANCING DAMPERS IN RETURN AND OUTDOOR AIR DUCTS AS SHOWNTO ALLOW PROPER BALANCING OF RETURN/OUTDOOR AIR.
OUTDOOR AIR DUCT, SEE FIRST FLOOR MECHANICAL PLAN FOR CONTINUATION
6
7
8
9
10
13 ROOF MOUNTED EQUIPMENT SHOWN FOR CLARITY
14 WALL MOUNTED RETURN GRILLE• INSTALL GRILLE AT A MINIMUM OF 6" A.F.F.• ROUTE RETURN DUCT FROM GRILLE TO BOTTOM RETURN OF UNIT.
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M2.1
SCHEDULES
OPTIONS-ACCESSORIES-NOTES
2. PROVIDE SINGLE POINT CONNECTION.
5. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT.
3. ACCEPTABLE MANUFACTURERS: CARRIER, TRANE, YORK, LENNOX
4. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT.
HEAT PUMPHEATING CAPACITY
(MBH)
1. PROVIDE COMPLETE WITH PROGRAMMABLE T'STATNOTES:
3. ACCEPTABLE MANUFACTURERS: CARRIER, TRANE, YORK, LENNOX
1. PROVIDE COMPLETE WITH COIL GUARDS
MARK
AHU-1
NOTES:
CFMSUPPLY
COOLING
(MBH)
CAPACITY
MOCPVOLT.-PH.-CY.
BACKUP ELECTR.RESIST. HEATING
KW
ELECTRICAL
MCAMANUFACTURER & MODEL
OPTIONS-ACCESSORIES-NOTES
ELECTRICAL
VOLT.-PH.-CY.INDOOR UNIT
HP-1
REFRIG. PIPING
SUCTION LIQUIDMANUFACTURER & MODEL
SPLIT SYSTEM HEAT PUMP - OUTDOOR UNIT SCHEDULE
SPLIT SYSTEM HEAT PUMP - INDOOR UNIT SCHEDULE
AHU-2
TOTAL
COOLING
(MBH)
CAPACITYSENSIBLE
EER
HP-2
COOLINGCAPACITY
(MBH)
HEATINGCAPACITY
(MBH)
AHU-3
HP-3
AHU-4
HP-4
7. PROVIDE UNIT WITH DUCT MOUNTED SMOKE DETECTORS IN SUPPLY AND RETURN DUCTS OF UNIT. DETECTORS TO BE PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR.
6. PROVIDE UNIT WITH AUXILIARY CONDENSATE DRAIN PAN UTILIZING SHUT DOWN FLOAT SWITCH. PROVIDE COMPLETE WITH CONDENSATE DRAIN PUMP CAPABLE OF ACHIEVING PROPER FLOW AS INDICATED BY DRAWINGS.
5. DURING AUXILIARY HEATING MODE OUTDOOR UNIT SHALL DE-ENERGIZE TO PREVENT SIMULTANEOUS OPERATION OF ACCESSORY HEAT AND HEAT PUMP.
9. WRAP UNITS WITH FOIL FACED FIBERGLASS OR CLOSED CELL ELASTOMERIC INSULATION. WRAP IN A MANNER TO ALLOW OPERATION/ACESS OF ALL FILTERS, CONTROL PANELS, ACCESS DOOR, S ETC.
8. DURING AUXILIARY HEATING MODE OUTDOOR UNIT SHALL DE-ENERGIZE TO PREVENT SIMULTANEOUS OPERATION OF ACCESSORY HEAT AND HEAT PUMP.
4. PROVIDE WITH FILTER RACK AND 1" THICK PLEATED-MEDIA DISPOSABLE FILTERS, EQUAL TO FARR 30/30.
HP-5
AHU-5
OUTDOORUNIT
MIN. O.A.AIR CFM
EXT. S.P.(IN. W.G.)
MCA MOCPMARK
KEF-1
NOTES:
DISCHARGE
VENTILATING FAN SCHEDULE
MODEL/CAT#DESIG. MFGR. TYPE H 2OCFMS.P.
h.p. / wattsMIN.
LEVELRPMFAN SONE
OPTIONS-ACCESSORIES-NOTES
1. PROVIDE COMPLETE WITH ROOF CURB, CURB TO OFFSET ANY ROOF SLOPE.2. PROVIDE COMPLETE WITH BUG SCREEN.3. INTERLOCK KEF-1 & KSF-1 WITH COOKING HOOD TO RUN SIMULTANEOUSLY.4. INTERLOCK DEF-1 WITH DISH HOOD TO RUN SIMULTANEOUSLY.5. FAN TO RUN CONTINUOUSLY.6. INTERLOCK FAN WITH LIGHTSWITCH.
2. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZING CALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.
ELECTRIC HEATER SCHEDULE
MFR.
EWH-1
MARK MODEL # VOLTS/PH.KW MOUNTING REMARKS
NOTES:
OPTIONS-ACCESSORIES-NOTES
EWH-2
EWH-3
EWH-4
1. PROVIDE WITH WALL RECESSED MOUNTING KIT.2. PROVIDE WITH HANGING KIT COMPLETE WITH VIBRATION ISOLATION ACCESSORIES.
VOLTS/ PH
MOCPTOTAL CAPACITY SENSIBLETOTAL CAPACITY wbdb VOLT.-PH.-CY.MCA
ELECTRIC
MAU-1
SERVICEMANUFACTURER & MODELSYSTEM MBHCOIL EAT
COOLING CAPACITIES
NO.EQUIPMENT
GAS FIRED ROOF MOUNTED MAKE UP AIR UNIT WITH DX COOLING
FAN(HP)
MAU-2
OPTIONS-ACCESSORIES-NOTESFAN(HP) (MBH)
INPUTEXT. S.P.(IN. W.G.)
SUPPLYAIR (CFM)
EXHAUSTAIR (CFM)
EXT. S.P.(IN. W.G.)
SUPPLY FAN SECTION EXHAUST FAN SECTION GAS HEATUNIT
WEIGHT(LBS)
wbdb
COIL LAT
dbLAT
HOT GAS RE-HEAT
TC(MBH)
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
FIELD MOUNTED CONTROLS SHALL INCLUDE A DUCT MOUNTED LEAVING AIR STAT AND A WALL MOUNTED STAT (SEE PLANS FOR LOCATION)ALL UNIT MOUNTED CONTROLS FOR COMPLETE OPERATION SHALL BE INSTALLED BY THE EQUIPMENT MANUFACTURER
13. UNIT SHALL INCLUDE INTEGRAL NON-FUSED DISCONNECT14. DUCT MOUNTED SMOKE DETECTORS PROVIDED BY ELECTRICAL, INSTALLED BY MECHANICAL15. UNIT SHALL INCLUDE A 30" HIGH FACTORY ASSEMBLED AND INSULATED ROOF CURB/PLENUM WITH VIBRATION ISOLATION RAILS16. UNIT SHALL BE AHRI LISTED AND CERTIFIED (COIL ONLY CERTIFICATION NOT ACCEPTABLE)17. COMPRESSORS SHALL HAVE 5 YEAR WARRANTY (PARTS ONLY)18. PROVIDE UNIT WITH DUCT MOUNTED SMOKE DETECTORS IN SUPPLY AND RETURN DUCTS OF UNIT. DETECTORS TO BE PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR.
MAXTEMP
RISE °F
19. PROVIDE HURRICANE CLIPS FOR ALL MAU ROOFTOP UNITS AND CURBS. SEE DETAIL ON M203.
HP-6
HP-7
AHU-6
AHU-7
AHU-1 ALL
AHU-6 ALL
HP-1
HP-6
AHU-2 ALL
AHU-4 ALL
HP-2
HP-4
AHU-5 ALL
AHU-7 ALL
HP-5
HP-7
AHU-3 ALL
HP-3
HP-8
AHU-8
AHU-8 ALL
HP-8
(MBH)OUTPUT
GUEST ROOM - OUTSIDE AIR / EXHAUST
GUEST ROOM - OUTSIDE AIR / EXHAUST
GREENHECK
MARKEL
MARKEL
MARKEL 3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1
MARKEL
EUH-1 REZNOR EGEB-5 5 208/1 SUSPENDED SUSPENDED FROM STRUCTURE W/ INTERGRAL T'STAT 2
3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1
3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT
3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT
1
1
EWH-5 MARKEL 3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1
CARRIER / FX4DNF061 2000 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0375
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2 208/3 21.1 30
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0400
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0425
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0265
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300
CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2
2000
2000
2000
2000
2000
2000
ELECTRIC DUCT HEATER SCHEDULE
ITEM MANUFACTURER MODEL NO. CFM KW STEPS VOLTS/ᴓ DIMENSIONS TEMP RISE (°F) NOTES
EDH-1 MARKEL HF 2456 23 2 208/3 30"W x 12"H 30 1
NOTES:1. INSERT TYPE WITH BUILT-IN FAN INTERLOCK, OVERTEMPERATURE CONTROL, CONTROL CONTACTOR, AND DUCT MOUNTED T-STAT.2. HEATER TO ENERGIZE AT 40°F AIR STREAM DETECTION.
208/3
208/3
208/3
208/3
208/3
208/3
KSF-1 GREENHECK
DEF-1 GREENHECK
CUBE-200 ROOF VERTICAL 3070 1.0 1.0 208/1 961 14.8
SAF-112 ROOF VERTICAL 2456 0.75 3/4 208/1 875 19.5
CUBE-101 ROOF VERTICAL 525 0.5 1/4 208/1 1162 5.8
1,2,3
1,2,3
1,2,4
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
CARRIER / FX4DNF025 800 0.5 23.0 17.38 22.3 3.8 208-1-60 26.0 30.0150
CARRIER / 25HCD424 22.3 23.0 12.0 NOTE 2 NOTE 2 208/1 17.7 25
21.1 30
21.1 30
21.1 30
21.1 30
21.1 30
21.1 30
STEEL
ALUM
ALUM
OPPOSED BLADE DAMPER
N/A
350RS
TMS
50F
24x24 LAY-IN/SURFACE MOUNTED SUPPLY DIFFUSER, ROUND NECK
EGGCRATE STYLE RETURN / TRANSFER GRILLE
SURFACE MOUNTED RETURN GRILLE N/A
FINISHAIR CONTROL MATERIAL
AIR DISTRIBUTION SCHEDULE
MODEL/CAT#DESCRIPTION
TITUS
TITUS
MFGR.
NOTES:
DESIG. OPTIONS-ACCESSORIES-NOTES
TITUS
1. ACCEPTABLE MANUFACTURERS: METALAIRE, ANEMOSTAT, OR BY ENGINEER2. PROVIDE COMPLETE WITH ALL CLIPS, MARGINS AND HARDWARE FOR INSTALLATION TYPE. CONTRACTOR/MFG REP SHALL EXAMINE DRAWINGS TO DETERMINE INSTALLATION TYPE.3. COORDINATE COLOR WITH ARCHITECT.4. SEE DRAWING FOR CONNECTION SIZE.
ALUMTBD-10 N/A 1,2,4TITUS HIGH ADJUSTABLE CAPACITY LINEAR SLOT WITH 10" or 8" INLET (2 x 1.5" SLOT WIDTH 4'-0" LONG)
3
3
3
3
A
B
D
C
E
1,2,4
1,2,4
1,2,4
F
TITUS
TITUS ALUM250-AASURFACE MOUNTED SUPPLY GRILLE (4 WAY THROW) N/A 3 1,2,4
ALUM350RSSURFACE MOUNTED RETURN GRILLE N/A 3 1,2,4
CARRIER / 62DCF020-S4B31FTD34020 3550 2.0 3.02.0 5 300 201.6 74.6 112.6 25.7 101 70 50.9 50.9 192.14 188.56 2500208/3100 125
CARRIER / 62DCJ024-V4B31G8D35805 4260 2.0 5.02.0 10 600 403.2 95.2 139.2 22.1 101 70 57.1 56.8 238.64 238.55 4000208/3120 150
ALL
ALL
GREENHECK SP-A70 CEILING 50 0.20 850115/120 watts 1.3 6HORIZONTALEF-2
GREENHECK SP-A70 CEILING 50 0.20 850115/120 watts 1.3 5HORIZONTALEF-1
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M2.2
SCHEDULES
VOLTSOA CFMCFMOUTDOORMANUFACTURERMARK
DUCTLESS A/C SCHEDULE - COOLING ONLY
INDOOR COOLING (MBH)INDOOR
1. SANYO OR MITSUBISHI ARE ACCEPTABLE ALTERNATIVES.2. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR.3. PROVIDE WITH MOUNTING KIT COMPATIBLE WITH WALL MOUNTING APPLICATION.
HWFC-1/HW-CU-1
OPTIONS-ACCESSORIES
NOTES:
5. PROVIDE ACCESSORY LONG RUN REFRIGERANT LINE KIT.
VOLTSOUTDOOR
(MCA/MOCP) (MCA/MOCP)
6. MAIN POWER SUPPLIED TO OUTDOOR UNIT. FIELD SUPPLIED CONNECTION CABLE FROM OUTDOOR TO INDOOR SUPPLIES POWER TO INDOOR UNIT.
7. PROVIDE CONDENSATE PUMP INSTALLED INSIDE UNIT (REMOTE MOUNT UNACCEPTABLE)8. PROVIDE WITH LOW AMBIENT OPERATION KIT, WIND BAFFLE & CRANKCASE HEATER.
4. ROUTE CONDENSATE DRAIN LINES AS SHOWN ON PLUMBING PLANS.
HI - MED - LOW
9. COORDINATE OUTDOOR UNIT MOUNTING TYPE WITH PLANS. (HOUSE KEEPING PAD OR METAL WALL BRACKET)
HWFC-2/HW-CU-2
038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9
PACKAGE THROUGH-THE-WALL A/C UNIT
HEATING (BTUH)MARK MANUFACTURER MODEL NO. TH
COOLING (BTUH)ENTERINGAIR
db wbEER VOLT/PH
ELECTRCAL DATA
NOTES:
CFM
TOT OA
2. CONDENSATE IS TO BE ROUTED TO CONDENSATE DRAINS SHOWN ON PLUMBING DRAWINGS.
MCA MOCP
PTAC-1 208/111.36780 9.0 8.1310 - 16.5 20GREE ETAC09HP208V20
OPTIONS-ACCESSORIES
ALL
3. PROVIDE COMPLETE WITH FACTORY SUB-BASE, HARDWIRE KIT AND POWER DISCONNECT SWITCH. ACCOUNT FOR SUB-BASE HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.
ELECTRICHEATER
(KW)
3.0
WEIGHT(LBS)
145
47°
4. PTAC RISER BY PLUMBING CONTRACTOR, CONNECTION FROM PTACS TO RISER BY MECHANICAL.5. ACCEPTABLE ALTERNATES ARE AMANA & GE. (VERIFY 277 VOLTAGE AVAILABILITY PRIOR TO SUBMITTING)
1. PROVIDE WITH WALL SLEEVE, STANDARD GRILLE, UNIVERSAL DRAIN KIT REMOTE MOUNTED MANUAL T-STAT WITH TWO SPEED FAN CONTROL CAPABILITY.
6. PROVIDE WITH REMOTE MOUNTED MANUAL T-STAT WITH TWO SPEED FAN CONTROL CAPABILITY.
HWFC-3/HW-CU-3
HWFC-4/HW-CU-4
HWFC-5/HW-CU-5
HWFC-6/HW-CU-6
1 32 4 5 7CARRIER 8 9
038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9
1 32 4 5 7CARRIER 8 9
038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9
1 32 4 5 7CARRIER 8 9
038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500
038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500
038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500
038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500
6
6
6
6
6
6
6
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M3.1
DETAILS
TYPICAL BOTTOM OF DUCT DIFFUSER CONNECTIONSCALE: NONE
SUPPLY DUCT MAIN
FLEX DUCT WHEREREQUIRED (MAX.
LENGTH 6'-0")
FLEX DUCT SIZES SHALLMATCH NECK SIZES
OPPOSED BLADEDAMPER
DRAW BAND WITHSILICONE SEALER
HAND DAMPER
CEILINGDIFFUSER
COLLAR
CEILING
DRAIN PAN
CONDENSATE DRAIN DETAILSCALE: NONE
EACH DIMENSION ISEQUAL TO FAN NEGATIVE
STATIC PRESSURE
UNIONREMOVABLE CAP
FULL SIZE OFDRAINCONNECTION
APPROVED AIRGAP HEIGHT
LOCAL ROOF DRAIN,FLOOR DRAIN, OR
FLOOR SINK.
LEVELING LEG
FOUNDATION WALL
OUTSIDE WALL
EXTERIOR LOUVER ANDDAMPER
LOCKED CONTROL PANEL
WALL SLEEVE
PTAC UNIT
PACKAGED THROUGH THE WALL TERMINAL AC UNITSCALE: NONE
ELECTRIC WALL HEATER MOUNTING DETAILSCALE: NONE
6" THICK CONC. PAD - EXTEND6" BEYOND UNIT ALL AROUND
SIGHT GLASS WITHMOISTURE INDICATOR
FILTER-DRYERCONDUIT - POWERAND CONTROL
REFRIGERANT LIQUID LINE
REFRIGERANT SUCTIONLINE WITH INSULATION
CONDENSING UNIT
FAN GUARD
CONDENSING UNIT - SLAB MOUNTED AT GRADESCALE: NONE
BACK-SEATED REFRIGERANTVALVE
DUCT HANGER DETAILSSCALE: NONE
SHEET METAL SCREW
SECURE TO STRUCTUREABOVE AS RECOMMENDEDBY SMACNA
HANGER RODTYPE "B" 5/16" DIA.TYPE "C" 3/8" DIA.TYPE "D" 1/2" DIA.
FOR BRACING ANGLESSEE NOTES
NUT & WASHER ATEND OF ROD
TYPE "A"
TYPE "B", "C", "D"
MAX SIDE MAX SIDERIVET OR BOLT TOBOTH SIDES OF DUCT& A MIN. OF 1" BENEATH DUCT FORBOTH STRAPS
1" X 16 GAGALV. IRONSTRAP ORALUMINUM
(8 FT. MAX HANGER SPACING. ALSOPROVIDE 3 HANGERS AT EACH TAKE-OFFOR BRANCH.)
(8 FT. MAX HANGER SPACING )
NOTES:
1.) FOR SEVERAL DUCTS ON ONE HANGER, TYPE "B", "C",OR "D" MAY BE USED. SIZE OF HANGER WILL BE SELECTED ON SUM OF DUCT WIDTHS EQUAL TO MAXIMUMWIDTH OF DUCT SCHEDULE.
2.) SCHEDULE FOR ANGLES FOR BRACING: TYPE "B" -1-1/2 X 1-1/2 X 1/8 ANGLE, MAX. SPACING 8'-0"CENTERS; TYPE "C" - 1-1/2 X 1-1/2 X 3/16 ANGLE,MAX. SPACING 8'-0" CENTERS; TYPE "D" - 2 X 2 X 1/4ANGLE, MAX SPACING 4'-0" CENTERS.
DUCT SCHEDULE
DUCTDIMENSIONS(INCHES)
TYPEHANGER
AA
A/B
B
B
BCC
DOVER 96
85 " 9661 " 8455 " 60
43 " 54
31 " 42
19 " 30
13 " 18UP THRU 12
OPENING HEIGHT
TOP BLADE RIVETED
TO FRAME
SLEEVE
COLLARSTEEL BLADES WITHINTERLOCKING JOINTS
BLADE AND LINK
CINCH
FUSIBLE LINK
STEEL FRAME
ASSEMBLED
INTO WELDED
HOUSING
1" TYPICAL
3 SIDES
3/4" TYP.
3 SIDES
DUCT HEIGHT LESS
1/4" 100% FREE-
AREA
(DAMPER HEIGHT
IS 1/4" LESS)
3"
5"
FIRE DAMPER DETAILSCALE: NONE
DUCT SUPPORTS OFF ROOF DETAILSCALE: NONE
INSULATION
METAL DECK
SUPPORT
PROVIDE PITCH WITH INSULATIONMATERIAL FOR DRAINAGE
STRUCTURAL SHAPEAS PER SMACNA(ANGLE IRON OR PIPE)
SUPPORT LEGSWELD TO ANGLE (TYPICAL)
ANGLE IRON FASTENEDTO EQUIPMENT SUPPORT
COUNTER FLASHING HOOD
MEMBRANE ROOF
PREFABRICATEDEQUIPMENT
INVERTED ANGLE IRON
ANCHOR EQUIPMENT SUPPORTTO METAL DECK
DUCTWORK SUPPORTED AS PER SMACNA
SEAL ALL ANGLES WEATHER TIGHT
ANGLE IRON WELD TO PIPEOR ANGLE IRON (TYPICAL)
AT ROOF DUCT SUPPORT-INSULATEOVER ANGLE IRON SUPPORTS ANDSEAL ALL CORNERS OF ANGLES IN AWEATHER TIGHT MANNER
MIN
IMU
M
2'-0
"
INSULATED DOUBLE WALL SUPPLY ORRETURN DUCTWORK WITH WATER TIGHTSEAMS AND WEATHER RESISTANT FINISH.
INLINE EXHAUST FANS (TYP)
MOTOR
BELT GUARD
FLOWAIR
FLEXIBLE CONNECTION
DUCTWORK
STEEL SPRING AND RUBBERIN SHEAR TYPE VIBRATIONISOLATORS
MOUNTING BRACKET
ADJUSTABLE SHEAVEDRIVE PULLEY
FLOW
DUCTWORK
AIR
FLEXIBLE CONNECTION
ADJUSTABLE MOTOR MOUNT
3/8"O ALL THREADED STEEL RODSSUPPORT FROM BUILDING STRUCTURE LENGTH OF RODS TO SUIT SPACEAVAILABLE
FIRE DAMPER AT SUPPLY REGISTER/GRILLE DETAILSCALE: NONE
(COOLING SUPPLY ONLY)DUCT TO PREVENT SWEATINGEXTERNAL INSULATION ON
RETURN OR FUSIBLE LINK
FIRE DAMPER
RETURN AIR GRILLE ORSUPPLY REGISTER
FIRE RATED WALL
SUPPLY DUCT
ABOVE CEILING IN-LINE MOUNTED EXHAUST FAN DETAILSCALE: NONE
FACTORY SUB- BASE KIT
6" ABOVE FINISHED FLOOR (MINIMUM)
UNIT RECESSED IN WALLPER MFG GUIDELINES
ELECTRIC HEATER,RECESSED WALL MOUNTED
SEE DETAIL A
1/2"
1" MIN.1 1/2"
CEILING RADIATION DAMPER DETAILSCALE: NONE
CURB AND EQUIPMENT HURRICANE CLIP DETAILSCALE: NONE
BELOW GRADE
ABOVE GRADE
AEED,Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369
P.O. BOX 4934408 McCALLIE AVE
inc.
AEED JOB NO. 029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.
714
cher
ry s
treet
, cha
ttano
oga,
tenn
esse
e 37
402
p.42
3 63
4 08
06 f
.423
752
849
9 w
ww
.rive
r-st
-arc
hite
ctur
e.co
m
Release Date:Project No.:
3/31
/201
5 10
:17:
24 A
M
1205
5 G
ATE
WA
Y W
ES
T B
LVD
, EL
PA
SO
, TX
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZAR
AG
OZA
HO
TEL
PA
RTN
ER
S, L
LC
MECHANICAL
M3.2
DETAILS
NOTES:
1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.
2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.
3 STRAP HANGER REQUIRED IF BRANCH RUNOUT LENGTH IS GREATER THAN 4 FT.
4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. FLEXIBLE DUCT SHALL BE INSULATED.STRETCH FLEXIBLE DUCT TO A MINIMUM OF 90% OF ITS FULLY EXTENDED LENGTH.SEAL CONNECTIONS AIR TIGHT.
5 HARD ELBOW TO AIR TERMINAL CONNECTION.
6 COMPRESSION FITTING AT AIR TERMINAL CONNECTION.
7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.
12 3
4
5
67
NOTES:
1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.
2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.
3 STRAP HANGER REQUIRED IF BRANCH RUNOUT LENGTH IS GREATER THAN 4 FT.
4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. STRETCH FLEXIBLE DUCT TO A MINIMUM OF90% OF ITS FULLY EXTENDED LENGTH. SEAL CONNECTIONS AIR TIGHT.
5 HARD ELBOW TO AIR TERMINAL CONNECTION.
6 SHEET METAL PLENUM. PLENUM SHALL BE SAME SIZE AS GRILLE CONNECTION.
7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.
12 3
4
5
6
7
NOTES:
1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.
2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.
3 STRAP HANGER REQUIRED IF RUN OUT LENGTH IS GREATER THAN 4 FT.
4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. STRETCH FLEXIBLE DUCT TO A MINIMUM OF90% OF ITS FULLY EXTENDED LENGTH. SEAL CONNECTIONS AIR TIGHT.
5 SPIN IN CONICAL BRANCH TAP FITTING. BRANCH RUNOUT DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET.
6 SHEET METAL PLENUM. PLENUM SHALL BE SAME SIZE AS GRILLE CONNECTION.
7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.
12 3
5 6
7
TYPICAL SUPPLY AIR TERMINAL CONNECTION
TYPICAL AIR TERMINAL CONNECTIONLIMITED CLEARANCE APPLICATION
SCALE: NONE
SCALE: NONE
TYPICAL RETURN & EXHAUST AIR TERMINAL CONNECTIONSCALE: NONE
CEILING EXHAUST FAN DETAILSCALE: NONE
FLEXIBLE CONNECTION
SUPPORT FAN FROMSTRUCTURE ABOVE WITHTHREADED RODS &VIBRATION ISOLATORS
PROVIDE INTEGRAL GRILLEUNLESS OTHERWISE INDICATED
PROVIDE FAN COMPLETE WITH BACKDRAFT DAMPER AND WALL CAP
CURB MTD.EQUIPMENT
MATERIALROOFING
ROOF
DISTANCE EQUAL TOINSULATION THICKNESS
INSULATIONROOF
LOWEST POINT
DECK
FINISHED ROOF ATMINIMUM, 12" ABOVE
NOTE:1. COORDINATE FLASHING DETAIL WITH ROOFING SYSTEM PROVIDER
TYPICAL ROOF CURB DETAILSCALE: NONE
AS REQ'D
12"
AS R
EQ'D
45
1" MAX.
4"
16 GA. SHEETMETAL
DRILL & CAULKIN FIELD.
1"INSULATIONPROVIDE WASHER FOR WATERTIGHT CONNECTION.
PIPING THRU ROOF DETAILSCALE: NONE
NOTE:PIPES TO EXIT IN HORIZONTALARRANGEMENT ONLY. DO NOTSTACK PIPES OVER ONE ANOTHER.
THICKNESS FROM TOP OF ROOFTO TOP OF DECK.
COMBINATION FIRE/SMOKE DAMPERSCALE: NONE
CONTROLLED ROUND OR RECTANGULAR DAMPERS, AND CAN BE MOUNTED IN A WIDESYSTEM IS DESIGNED FOR USE WITH EXTERNALLY 1)
NOTES: LINEAR SLOT DIFFUSER
RIGID DUCTWORK
FLEXIBLE DUCTWORK
AND WIRE (50'-0"
RACK & PINION
FLEXIBLE CASING
MAXIMUM)
OPERATOR
MOUNTING BRACKET
VARIETY OF LOCATIONS INCLUDING CEILING JOISTS, LAY-IN CEILINGS, BEHIND GRILLES,SOCKET WRENCH
WITH PLENUM BOX
LOCKING
CABLE SHALL CONSIST OF 0.054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1/16" FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH.
LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE USED TO CONVERT ROTARY MOTION INTO PUSH-PULL MOTION.
CONTROL SHAFT SHALL BE "D"-STYLE FLATTENED 1/4" DIAMETER WITH 265° ROTATION PROVIDING 1-1/2" LINEAR TRAVEL CAPABILITY.
2)
3)
4)
ON OR INSIDE OTHER VARIOUS TYPES OF DIFFUSERS, ETC.
RECTANGULARROUND DAMPER OR
OPPOSED BLADE DAMPER
CABLE CONTROLLED DAMPER DETAILSCALE: NONE
ALL RELAYS, WIRING AND TRANSFORMERS REQUIRED TO INTERLOCKSMOKE DETECTOR WITH SMOKE DAMPER OPERATOR ARE THE
RESPONSIBILITY OF DIV. 15000