108kw 135kva perkins 1106c-e66tag2

5
 Techni cal Specifi cation Gen-set model: R-P135 1 Generator Rating P.F Standb y Rating Prime Rating Voltage HZ Phase COS¢) Standby  Amp s KVA KW KVA KW 380 50 3 0.8 226 148.5 118 .8 135 108 400 50 3 0.8 214 148.5 118 .8 135 108 Prime Power (PRP):  Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97 eqv ISO8528; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales prom ises products. Each and every is strictly factory tested . Each generator set has been got through 2 hours load test for running 0%, 25% ,50%, 75% ,100% and 110% load. All protective devices and control function are simulated and checked before despatch Warranty is according to our standard conditions: 1000 hours operation time, or 12 months since the purchase date, or 15 months since the generator leave the factory. The time which is due first is used as the criterion. Design Standards  Conform Europe (CE)  China Compulsory Certificate (CCC)  ISO 8528-1995  GB/T2820-1997 Standard Features  Origin UK Perkins Engine, model 1106C-E66TAG2  Radiator 40°C Max, fans driven by belt, with safety guard  24V charge alternator  Coupled to Stamford Alternator UCI274E  Isolation Class H & IP23 Protection  Dry Type Air Filter, Fuel Filter, Oil Filter  Main line curcuit breaker  Standar d control panel  Batteries, Rack and Cable  Flexible exhaust pipe, Exhaust siphon, Flange, Muffler  User Manual & Electric Drawing Picture for reference

Upload: dave-wallace

Post on 02-Mar-2016

46 views

Category:

Documents


0 download

DESCRIPTION

Technical Data

TRANSCRIPT

7/18/2019 108kw 135kva Perkins 1106C-E66TAG2

http://slidepdf.com/reader/full/108kw-135kva-perkins-1106c-e66tag2 1/4

  Technical Specification Gen-set model: R-P135 

1

Generator Rating

P.F Standby Rating Prime RatingVoltage HZ Phase

(COS¢)

Standby

 Amps KVA KW KVA KW

380 50 3 0.8 226 148.5 118.8 135 108

400 50 3 0.8 214 148.5 118.8 135 108

Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, inaccordance with GB/T2820-97(eqv ISO8528); A 10% overload capability is available for a period of 1 hour within a

12-hour period of operation.

Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the

duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at

this rating.

Sales promises

products. Each and every is strictly factory tested . Each

generator set has been got through 2 hours load test for running 0%, 25% ,50%, 75% ,100% and 110% load. All protective

devices and control function are simulated and checked before despatch

Warranty is according to our standard conditions: 1000 hours operation time, or 12 months since the purchase date, or 15

months since the generator leave the factory. The time which is due first is used as the criterion.

Design Standards

  Conform Europe (CE)

  China Compulsory Certificate (CCC)

  ISO 8528-1995

  GB/T2820-1997

Standard Features

  Origin UK Perkins Engine, model

1106C-E66TAG2

  Radiator 40°C Max, fans driven by belt, with

safety guard

  24V charge alternator

  Coupled to Stamford Alternator UCI274E

  Isolation Class H & IP23 Protection

  Dry Type Air Filter, Fuel Filter, Oil Filter

  Main line curcuit breaker

  Standard control panel

  Batteries, Rack and Cable

  Flexible exhaust pipe, Exhaust

siphon, Flange, Muffler  User Manual & Electric Drawing Picture for reference

7/18/2019 108kw 135kva Perkins 1106C-E66TAG2

http://slidepdf.com/reader/full/108kw-135kva-perkins-1106c-e66tag2 2/4

  Technical Specification Gen-set model: R-P135 

2

 Appl ication Data

Installation Place Indoor (well ventilated)

 Ambient Temperature -25℃ to 45℃ (Heater is needed Below 5℃)

 Ambient Humidity Less than 80%

 Altitude Maximum 1,000m above sea Level

Engine Data

Manufacturer/Model UK origin PERKINS engine model 1106C-E66TAG2

Type6 cylinders,4 stroke, Turbocharged and air to air charge

cooled

Combustion system Direct inject

Cylinder Arrangement 6 in line

Displacement 6.6 L

Bore and Stroke 105*127 (mm)

Compression Ratio 16.2:1

Direction of rotation Anti-clockwise,viewed on flywheel

Rated RPM 1500RPM

Max Standby Power at rated RPM 133 KW /178 hp

Starting method Electric motor 14V

Fuel filter Full flow,cartridge type

Oil filter Full flow,cartridge typeGovernor Type Electronic

Fuel Consumption

100% (Prime Power) Load 209 g/kw.h

75% (Prime Power) Load 216 g/kw.h

50% (Prime Power) Load 219 g/kw.h

 Ai r In let

Mounted air filter and turgocharged

Fuel System

Fuel filter

Lubrication System

Flat-bottomed isolated aluminium sump

7/18/2019 108kw 135kva Perkins 1106C-E66TAG2

http://slidepdf.com/reader/full/108kw-135kva-perkins-1106c-e66tag2 3/4

  Technical Specification Gen-set model: R-P135 

3

Oil filter

Cooling System

24’’ belt-driven pusher fan and guards 

Radiator (incorporating air-to-air cooler + fuel cooler

Water pump

Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1395 Standards

 Al ternator Data

 Alternator Manufacturer StamfordNumber of Phase 3

Connection Type 3 Phase and 4 Wires,”Y” Type connecting

Number of pole 4

Power Factor 0.8

Protection Grade IP23

 Altitude ≤1000m

Cooling system IC01

Exciter Type Brushless, Self-Exciting

Insulation Class HWinding pitch 2/3

Rotor support type Single type

Voltage regulation +/-1%

 At no load <1.5%Total harmonic TGH/THC

On load <2%

Wave form NEMA (TIF) <50

Wave form IEC (THF) <2%

Generating Set Data

Voltage Regulation ≥±5%

Voltage Regulation, Stead State ≤±1%

Sudden Voltage Warp(100% Sudden Reduce) ≤±25%

Sudden Voltage Warp(Sudden Increase) ≤-20%

Voltage Stable Time(100% Sudden Reduce) ≤6s

Voltage Stable Time(Sudden Increase) ≤6s

Frequency Regulation, Stead State ≤5%

Frequency Waving ≤0.5%

Sudden Frequency Warp(100% Sudden Reduce) ≤+12%

General Data

7/18/2019 108kw 135kva Perkins 1106C-E66TAG2

http://slidepdf.com/reader/full/108kw-135kva-perkins-1106c-e66tag2 4/4

  Technical Specification Gen-set model: R-P135 

4

Sudden Frequency Warp(Sudden Increase) ≤-10%

Frequency Recovery Time(100% Sudden Reduce) ≤5s

Frequency Recovery Time(Sudden Increase) ≤5s

Options

Engine Fuel System Alternator

  Pre-Heater

  Battery Charger

  Remote Radiator

  Daily Fuel Tank

  Water Separator

  Fuel feed pump

  Anti Condensation Heater

  Permanent Magnet Generator(PMG)

  Drop CT( Paralleling)

Contro l Type Others

  Remote Control Panel

  Auto Transfer Switch(ATS)

  Paralleling System

  Weather Proof Type

  Sound attenuated Type

  Trailer Type

  Spare Part

  50℃ Radiator

  Exhaust Pipe Kits

Overall Dimension

Standard configuration

(Open Type)

Overall Size: L*W*H (mm)

2650mm*730mm*1650mmWeight: 1,700kgs

Standard configuration

(Slient or waterproof Type)

Overall Size: L*W*H (mm)

3300mm*1200mm*1490mm

Weight: 2200kg