    11 unique Points of Yamazen Flash Systems

    1 Yamazens proprietary Rf Gradient has been designed to elute the target

    compound at 4-CV minimizing the run time, solvent use and waste disposal

    while achieving the good sample separations. Less solvent use means less

    costs to acquire solvent and dispose waste, and its Eco-friendly. The sample

    elution at 4-CV is equivalent to eluting the sample at the speed of Rf 0.25,

    which is a proven fact that good separations are achieved in the normal phase

    silica column chromatography.

    2 Yamazen UV detectors provide a broad detection range from 0.04 O.D. to 4.0

    O.D. Thus, any samples ranging from thin and low UV absorbance samples to

    thick and high UV absorbance samples can be well detected and collected

    without any loss.3 Yamazen is the one and only company that have successfully transferred the

    method from TLC to column chromatography. Yamazen silica columns well

    correlate with the world famous Merck TLC. Just enter the TLC Rf value of the

    target compound and the solvent mixture ratio, and the optimized Gradient

    method to elute the target compound at 4-CV (or at the eluting speed of

    Rf0.25) will be automatically developed. There are companies who use

    spherical silica packed columns. Those columns will not correlate with TLC,

    because the TLC has irregular silica on it, and not spherical silica.

    4 Benefits of using Inject Column: It contributes to the better sample purification

    and separation to use an Inject Column as a sample-loading column together

    with a main separation column like Yamazen Universal Column, which makes

    the downsizing of a column possible. An Inject Column also eliminates the

    harmful effect (co-eluting of the sample) caused by highly polar solvent when it

    is used to dissolve a tough-to-dissolve sample.

    5 Sample loading software: Just input TLC Rf values of the target compound and

    the nearest impurity, and the maximum sample load for each selected column

    will be automatically calculated and displayed. Its an excellent tool to quickly

    choose the best-suited column for the sample. Scale up and down can be

    done freely.

    6 Ultra Slow Gradient (0-3% over 30 minutes): Mixture of polar solvents needs to

    be precisely controlled when purifying samples of which Rf value change

    largely by the amount of polar solvent like chloroform and methanol. Equipped

    with the upgraded firmware along with the high precision valves, the ultra slow

  • 7/28/2019 11 Unique Points..

    2/3

    11 unique Points of Yamazen Flash Systems

    gradient is available with Yamazen systems. Running on the gradient, sample

    bands become narrower to achieve a great purification, and the eluting position

    can be controlled precisely.7 Parallel detection between UV detector and ELSD or RI detector is possible

    with Yamazen flash systems (Option). The ELSD-100X offers a wide dynamic

    range and the ability to handle high concentrations of samples, which is critical

    for the flash purifications. It is of the stand-alone compact design and add-on

    device: The smallest footprint available in industry. The RI detector, RI-31

    features that the baseline gets stabilized fast, and chromatography can be

    done at high flow rate up to 100ml/min. Using both an UV detector and anELSD or a RI detector boosts productivity and efficiency since each detector

    can be used for the compounds on which it works best.

    8 Toluene can be used as an elution solvent with Yamazen flash systems. When

    running with elution solvents such as hexane/ethyl acetate or

    chloroform/methanol, condensed ring aromatic compounds or compounds with

    many aromatic rings to be used to develop organic electronic industrial

    materials such as organic electro-luminescence can be crystallized or many

    not be retained by solid phase of a separation column long enough. This will

    result in poor separations. In that case, the sample separation will be improved

    by using toluene as one of the elution solvents. A wide detection range of

    Yamazen UV detectors allows Toluene to use as a elution solvent.

    9 TLC Image Reader, Cat No. A272, RE-X10 (Option): Rf input directly from the

    TLC image is possible! Place the TLC plate on the TLC Image Reader. Just

    with a few clicks on the monitor, the TLC image is shot, stored, and Rf values

    of the target compounds are automatically calculated. Rf values are then

    entered as parameters to use for Automatic Method Setup and also for the

    sample loading software.

    Equipped with a built-in UV light source and a camera.

    By shooting the TLC plate and clicking the target compound on the TLC

    plate, the Rf value of the target compound will be calculated and the

    optimized chromatography method will be developed automatically.

    The TLC plate is displayed on the screen during run. Compound spots

    on the TLC plate and the compound peaks both are displayed on the

  • 7/28/2019 11 Unique Points..

    3/3

    11 unique Points of Yamazen Flash Systems

    screen.

    Both the photographic image of the TLC plate and the purification are

    saved as a data file.

    Click the target compound and the nearest impurity on the TLC plate,

    and the maximum sample load for each column will be automatically

    calculated. Thus, enabling the chemists to choose the best-suited

    column for their sample.

    10

    Real Time Pressure Monitor: The precision pressure mater makes it possible

    to do real time monitoring of the pressure building up inside the column. When

    pressure hits the preset limit, the pump will stop as quickly as a flash, which

    will protect the system from being damaged. Highly responding pressure

    moderation system (PMS) prevents disposable plastic column and glass

    column from bursting, and allows the sample run to continue. Yamazen's motto

    is "Safety First!

    11 External Nozzle Cleaning System (Option): External Nozzle Cleaning System

    removes the crystallized samples accumulated on the outside of the

    fraction nozzles and cleans well. Cross contamination is a big concern in

    flash chromatography. This system cleans outside of the fraction nozzles

    as well as inside. Thus, pure fractions will always be collected. This

    device keeps entire solvent lines always clean. (Patent No. 4551364)