1111 site plan - africa architecture | make place in africa for...

6
UP 1 2 3 4 5 6 7 8 A B C Courtyard PROPOSED New House Retainin g Wall 5m Building l ine 2,5m Building line Boundary Line 5m B ui ld i ng lin e 2,5m Buil din g l ine Bo un d ary Line 5m Building line 2,5m Building line Bo undary Line 9 2m Servetude 2m S e r v etude 2m Servetude 2m S er v e tud e 2 , 5m Build in g lin e 5 m Bui l d ing l i n e 10500 25140 404 8 0 37 19 0 ERF 750 REMAINDER OF CLARENS 578 ERF 752 Clarens Extension 7 ERF 751 A B C D E Electric Box Le Roux Street No Obstruction To Entrance 5205 Retaining wall R etai n i n g wa l l Retaining wall Re t a in i n g w all 5544 Slate tiles Slate tiles Slate tiles Slate tiles Water channel Water channel Water channel 1800 mm x 22 0mm Thick bag plastered brick b oundary wall 1800m m x 2 2 0mm T hick ba g p laste red b rick bou n dary w al l 1800mm x 2 20mm Thick b ag plastere d brick b ou nd ary wall Bou n d a ry L i n e 18 00 mm x 2 2 0 mm Thi ck b ag p l a s t e re d b ri c k bo un da ry w a l l Halfbrick paving Halfbrick paving Lightweight steel roof structure Water channel PROJECT NUMBER DRAWN PROJECT ARCHITECT SCALE DRAWING NUMBER DATE - DRAWING DESCRIPTION PROJECT DESCRIPTION 5 GUILD HOUSE 239 BRONKHORST STREET NIEW MUCLENEUK 0181 SOUTH AFRICA PO.BOX. 1852 GROENKLOOF, 0027 TEL: (012) 460 3226/7/8 FAX: (012) 346 4168 E-MAIL: [email protected] ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH THE NATIONAL BUILDING REGULATIONS (ACT NO 103 OF 1977) INCLUDING ALL AMMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES. ALL LEVELS DIMENSIONS AND STEPS ARE TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK. ANY INDISTINCTNESS OR INDISCREPANCIES MUST IMMEDIATELY BE POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE. DRAWINGS ARE NOT TO BE SCALED FOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TO ENCROACH BOUNDARY ALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUT BY A REGISTERED TRADESMAN BRICKFORCE IS TO BE INSTALLED EVERY 5 COURSES OF BRICKWORK PROVIDE DPC TO WALL AT SLAB LEVEL, UNDER ALL CILLS AND TO ALL CHANGES IN FLOOR LEVELS ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OF SANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCAL AUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS. PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT GROUND LEVEL. MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40. PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS. PROVIDE A.E. TO FOOT OF ALL SOIL STACKS. I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES. ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN CONCRETE OF MINIMUM 100mm THICKNESS ALL ROUND PIPE. 0 - 0.75 SQM 3mm GLASS 0,75 - 1,5 SQM 4mm GLASS 1,5 - SQM 6mm GLASS WINDOWS AND SIDELIGHTS LOWER THAN 300mm FROM FLOOR 6MM SAFETY GLASS. SLIDING OR FRENCH DOORS 6MM SAFETY GLASS WITH SAFETY INDICATORS GENERAL NOTES: REVISION NO. Tender Drawings DRAINAGE NOTES: GLASS NOTES: 20361/2/ Morne Pienaar PrArch7241 Inge Raubenheimer Jaco Botha 0 1 : 100 2017/05/25 12:13:32 PM Site Plan 20 352 Proposed New House, ERF 751, Extension 7, Clarens 2014-06-26 1100 1 : 100 1 1 1 Site Plan NORTH

Upload: lamdat

Post on 22-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

UP

1 2 3 4 5 6 7 8

A

B

C

Courtyard

PROPOSEDNew House

Reta

inin

g W

all

5m

Build

ing li

ne

2,5

m B

uild

ing li

ne

Boundary

Lin

e

5m Building line

2,5m Building line

Boundary Line

5m

Build

ing li

ne

2,5

m B

uild

ing li

ne

Boundary

Lin

e

9

2m

Serv

etu

de

2m Servetude

2m

Serv

etu

de

2m Servetude

2,5m Building line

5m Building line

1050

0

25140

40480

37190

ERF 750

REMAINDER OFCLARENS 578

ERF 752

ClarensExtension 7

ERF 751

A

B

C

D

E

ElectricBox

Le

Rou

x S

tree

t

No O

bstr

uction

To E

ntr

ance

5205

Retaining wallRetaining wall

Retaining wallRetaining wall

5544

Slate tiles

Slate tiles

Slate tiles

Slate tiles

Water channel

Water channel

Wate

r channel

1800m

m x

220m

m T

hic

k b

ag p

last

ere

d b

rick

boundary

wall

1800mm x 220mm Thick bag plastered brick boundary wall

1800m

m x

220m

m T

hic

k bag p

last

ere

d b

rick

boundary

wall

Boundary Line

1800mm x 220mm Thick bag plastered brick boundary wall

Halfbrick paving

Halfbrick paving

Lig

htw

eig

ht ste

el ro

of str

uctu

re

Water channel

PROJECT NUMBERDRAWNPROJECT ARCHITECT

SCALE

DRAWING NUMBER

DATE-

DRAWING DESCRIPTION

PROJECT DESCRIPTION

5 GUILD HOUSE239 BRONKHORSTSTREETNIEW MUCLENEUK 0181SOUTH AFRICAPO.BOX. 1852GROENKLOOF, 0027

TEL: (012) 460 3226/7/8FAX: (012) 346 4168

E-MAIL: [email protected]

ALL MATERIALS AND CONSTRUCTION MUST COMPLYWITH THE NATIONAL BUILDING REGULATIONS(ACT NO 103 OF 1977) INCLUDING ALLAMMENDMENTS AS WELL AS THE BY-LAWS OF THELOCAL AUTHORITIES.

ALL LEVELS DIMENSIONS AND STEPS ARE TO BE CHECKEDAND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK.

ANY INDISTINCTNESS OR INDISCREPANCIES MUSTIMMEDIATELY BE POINTED OUT TO THE ARCHITECTFOR RECTIFICATION OR EXPLANATION BEFORE ANYCONSTRUCTION CAN COMMENCE.

DRAWINGS ARE NOT TO BE SCALEDFOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TOENCROACH BOUNDARYALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUTBY A REGISTERED TRADESMAN

BRICKFORCE IS TO BE INSTALLED EVERY 5 COURSES OFBRICKWORKPROVIDE DPC TO WALL AT SLAB LEVEL, UNDER ALL CILLSAND TO ALL CHANGES IN FLOOR LEVELS

ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OFSANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCALAUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS.

PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLEMARKERS AT GROUND LEVEL.MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40.PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS.PROVIDE A.E. TO FOOT OF ALL SOIL STACKS.I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES.ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TOBE ENCASED IN CONCRETE OF MINIMUM 100mm THICKNESS ALLROUND PIPE.

0 - 0.75 SQM 3mm GLASS0,75 - 1,5 SQM 4mm GLASS1,5 - SQM 6mm GLASS

WINDOWS AND SIDELIGHTS LOWER THAN 300mm FROM FLOOR6MM SAFETY GLASS. SLIDING OR FRENCH DOORS 6MM SAFETYGLASS WITH SAFETY INDICATORS

GENERAL NOTES:

REVISION NO.

Tender Drawings

DRAINAGE NOTES:

GLASS NOTES:

20361/2/

Morne PienaarPrArch7241

Inge RaubenheimerJaco Botha

0

1 : 100

2017/0

5/2

5 1

2:1

3:3

2 P

M

Site Plan

20 352

Proposed New House, ERF751, Extension 7, Clarens

2014-06-26

1100

1 : 1001111 Site Plan

NORTH

Living RoomSlate Tiles

KitchenSlate Tiles

Court YardSlate Tiles

1 2 3 4 5 6 7 8

A

B

C

Bosca oven

2

4100

2

4100

Broomcloset

Fridge& Freezer

OpenShelves

9

12

3

4

5

6

7

8

9

10

11

1 2 3 4 5 6

1 2 3 4 5 6

1

4100

1

4100

1791.650

1791.480

12

3

4

5

6

1792.330

1792.8501793.150

Slate tiles

Slate tiles

Slate tiles

Water Channel

Water Channel

Wate

r C

hannel

Wate

r C

hannel

Spiral steel staircase toroof area according toengineer specifications

Patio 02Slate Tiles

Patio 01Slate Tiles

pb

Sink

Downpipe into channel

1791.820

1791.990

1792.160

1792.330

1792.500

Water Spout

Water Channel

Water Channel

Water Channel

Water Channel

Water Channel

Water Channel

Wate

r C

hannel

Project Number

Sheet Number

Date

Ground Floor Plan 20 352

2100

05/27/14

Proposed New House, ERF 751, Extension 7,Clarens

1 : 501111 Ground Floor Level

NORTH

NORTH

Bathroom 01Slate Tiles

1 2 3 4 5 6 7 8

A

B

C

Stair

S

2

4100

2

4100

9

21

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Built in bench

1

4100

1

4100

Bedroom 01Slate Tiles

Spiral steel staircase toroof area according toengineer specifications

1795.050

Double

Volu

me

Balcony 01Slate Tiles

Balcony 02Slate Tiles

Bosca oven

whb

B

Downpipe into channel

Mild steel cat ladder tomezzanine level as perarchitects details acc. toengineer specifications

1 2

B

C

2

4100

1

4100

Bunk BedroomTimber Floor

Mild steel cat ladder tomezzanine level as perarchitects details acc. toengineer specifications

573

N01

WT08

Project Number

Sheet Number

Date

First Floor Plan 20 352

2101

06/02/14

Proposed New House, ERF 751, Extension 7,Clarens

1 : 501111 First Floor Level

NORTH

1 : 502222 Mezzanine Level

NORTH

1 2 3 4 5 6 7 8

A

B

C

2

4100

2

4100

9

1

4100

1

4100

1000mm High steel balustrade on top of upstand beam

1000m

m H

igh s

teel balu

str

ade o

n top o

f upsta

nd b

eam

1000m

m H

igh s

teel balu

str

ade o

n top o

f upsta

nd b

eam

680m

m H

igh b

rick p

ara

pet w

all

680m

m H

igh b

rick p

ara

pet w

all

680mm High brick parapet wall

Reinforced concrete roofslab according to engineerspecifications

Mild steel channel withdrip chain acc. toarchitects detaill

Fall

Fall

Fall

100mm pipe through upstand

Concrete water spoutacc. to architects details

Water channel

Water channel

Wate

r channel

Wate

r channel

1798.620

1791.480

Project Number

Sheet Number

Date

Roof Plan 20 352

2400

06/02/14

Proposed New House, ERF 751, Extension 7,Clarens

1 : 501111 Roof Plan

NORTH

First Floor Level

1795050

123456789

Lower Ground Floor

1791480

Roof Level

1798620

Ground Floor Level

1792500

First Floor Level

1795050

ABC

Roof Level

1798620

Ground Floor Level

1792500

First Floor Level

1795050

1 2 3 4 5 6 7 8 9

Roof Level

1798620

A B C

Lower Ground Floor

1791480

Lower First Floor

1795050

Roof Level

1798620

PROJECT NUMBERDRAWNPROJECT ARCHITECT

SCALE

DRAWING NUMBER

DATE-

DRAWING DESCRIPTION

PROJECT DESCRIPTION

5 GUILD HOUSE239 BRONKHORSTSTREETNIEW MUCLENEUK 0181SOUTH AFRICAPO.BOX. 1852GROENKLOOF, 0027

TEL: (012) 460 3226/7/8FAX: (012) 346 4168

E-MAIL: [email protected]

ALL MATERIALS AND CONSTRUCTION MUST COMPLYWITH THE NATIONAL BUILDING REGULATIONS(ACT NO 103 OF 1977) INCLUDING ALLAMMENDMENTS AS WELL AS THE BY-LAWS OF THELOCAL AUTHORITIES.

ALL LEVELS DIMENSIONS AND STEPS ARE TO BE CHECKEDAND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK.

ANY INDISTINCTNESS OR INDISCREPANCIES MUSTIMMEDIATELY BE POINTED OUT TO THE ARCHITECTFOR RECTIFICATION OR EXPLANATION BEFORE ANYCONSTRUCTION CAN COMMENCE.

DRAWINGS ARE NOT TO BE SCALEDFOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TOENCROACH BOUNDARYALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUTBY A REGISTERED TRADESMAN

BRICKFORCE IS TO BE INSTALLED EVERY 5 COURSES OFBRICKWORKPROVIDE DPC TO WALL AT SLAB LEVEL, UNDER ALL CILLSAND TO ALL CHANGES IN FLOOR LEVELS

ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OFSANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCALAUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS.

PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLEMARKERS AT GROUND LEVEL.MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40.PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS.PROVIDE A.E. TO FOOT OF ALL SOIL STACKS.I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES.ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TOBE ENCASED IN CONCRETE OF MINIMUM 100mm THICKNESS ALLROUND PIPE.

0 - 0.75 SQM 3mm GLASS0,75 - 1,5 SQM 4mm GLASS1,5 - SQM 6mm GLASS

WINDOWS AND SIDELIGHTS LOWER THAN 300mm FROM FLOOR6MM SAFETY GLASS. SLIDING OR FRENCH DOORS 6MM SAFETYGLASS WITH SAFETY INDICATORS

GENERAL NOTES:

REVISION NO.

Tender Drawings

DRAINAGE NOTES:

GLASS NOTES:

20361/2/

Morne PienaarPrArch7241

Inge RaubenheimerJaco Botha

0

1 : 100

2017/0

5/2

5 2

:35:0

1 P

M

Elevation

20 352

Proposed New House, ERF751, Extension 7, Clarens

2014-06-26

3100

1 : 1001111 North Elevation

1 : 1002222 East Elevation

1 : 1003333 South Elevation

1 : 1004444 West Elevation

Ground Floor Level

1792500

First Floor Level

1795050

Foundation Level

1790880

1 2 3 4 5 6 7 8 9

Lower Ground Floor

1791480

KitchenSlate Tiles

Bathroom 01Slate Tiles

Bedroom 01Slate Tiles

Roof Level

1798620

Mezzanine Level

1797575

Bunk BedroomTimber Floor

Foundation Level

1790880

A B C

Lower Ground Floor

1791480

Lower First Floor

1795050

Roof Level

1798620

Mezzanine Level

1797575

Bedroom 01Slate Tiles

Bathroom 01Slate Tiles

Bunk BedroomTimber Floor

KitchenSlate Tiles

Living RoomSlate Tiles

Balcony 02Slate Tiles

Patio 02Slate Tiles

PROJECT NUMBERDRAWNPROJECT ARCHITECT

SCALE

DRAWING NUMBER

DATE-

DRAWING DESCRIPTION

PROJECT DESCRIPTION

5 GUILD HOUSE239 BRONKHORSTSTREETNIEW MUCLENEUK 0181SOUTH AFRICAPO.BOX. 1852GROENKLOOF, 0027

TEL: (012) 460 3226/7/8FAX: (012) 346 4168

E-MAIL: [email protected]

ALL MATERIALS AND CONSTRUCTION MUST COMPLYWITH THE NATIONAL BUILDING REGULATIONS(ACT NO 103 OF 1977) INCLUDING ALLAMMENDMENTS AS WELL AS THE BY-LAWS OF THELOCAL AUTHORITIES.

ALL LEVELS DIMENSIONS AND STEPS ARE TO BE CHECKEDAND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK.

ANY INDISTINCTNESS OR INDISCREPANCIES MUSTIMMEDIATELY BE POINTED OUT TO THE ARCHITECTFOR RECTIFICATION OR EXPLANATION BEFORE ANYCONSTRUCTION CAN COMMENCE.

DRAWINGS ARE NOT TO BE SCALEDFOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TOENCROACH BOUNDARYALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUTBY A REGISTERED TRADESMAN

BRICKFORCE IS TO BE INSTALLED EVERY 5 COURSES OFBRICKWORKPROVIDE DPC TO WALL AT SLAB LEVEL, UNDER ALL CILLSAND TO ALL CHANGES IN FLOOR LEVELS

ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OFSANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCALAUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS.

PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLEMARKERS AT GROUND LEVEL.MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40.PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS.PROVIDE A.E. TO FOOT OF ALL SOIL STACKS.I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES.ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TOBE ENCASED IN CONCRETE OF MINIMUM 100mm THICKNESS ALLROUND PIPE.

0 - 0.75 SQM 3mm GLASS0,75 - 1,5 SQM 4mm GLASS1,5 - SQM 6mm GLASS

WINDOWS AND SIDELIGHTS LOWER THAN 300mm FROM FLOOR6MM SAFETY GLASS. SLIDING OR FRENCH DOORS 6MM SAFETYGLASS WITH SAFETY INDICATORS

GENERAL NOTES:

REVISION NO.

Tender Drawings

DRAINAGE NOTES:

GLASS NOTES:

20361/2/

Morne PienaarPrArch7241

Inge RaubenheimerJaco Botha

0

1 : 50

2017/0

5/2

6 9

:59:4

4 A

M

Sections AA - BB

20 352

Proposed New House, ERF751, Extension 7, Clarens

2014-06-26

4100

1 : 501111 Section AA

1 : 502222 Section CC