111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
DESCRIPTION
111TRANSCRIPT
-
CASE STUDY
COMMERCIAL COMPLEX
SAKET
-
LOCATION
-
INTRODUCTION It is a commercial cum recreational hub located in Saket, South Delhi.
PLOT AREA:15884.5SQ.M
BUILT UP AREA:62862 SQ.M
COMMERCIAL:24281SQ.M
RETAIL:8498SQ.M
LANDSCAPED AREA:15782SQ.M
It was opened in 2007 for public.
It is planned such that the district centre
consists of 1,500,000 sq ft (140,000 m2) of
retail space boasting of top Indian and
international brands, two multiplexes and a
five star hotel.
There are six functional malls:
1. Select Citywalk,
2. Office buildings
3. DLF place
4. hotel-hilton inn
5. multiplex
6. Open air theatre
-
ACCESSIBILITY
MALVIYA NAGAR METRO STATION 1.5KM
-
SAKET METRO STATION 3.1 KM
-
SITE PLAN
It is easily accessible through PUBLIC TRANSPORT i.e. DTC buses, Metro rail, Auto rickshaws,
And through private vehicles.
There is problem in crossing of road as no Pedestrian facility like FOB,
Subway is provided near
by to it. So, number of modal conflicts are more
-
CONCEPT
COURTYARD PLANNING
INTROVERT PLANNING
-
Select citywalk is spread over 6
acres. and includes a multiplex,
serviced apartments, offices and
public spaces
The planning of the SELECT
CITYWALK mall is divided into 4
categorization-
a. Family & tradition space
b. Celebration (centre-stage)
c. High- voltage (youth)
d. Open plaza/landscaped area
(ground floor)
BUT, the actual planning is
different from concept
planning.
CONCEPT- SELECT CITY WALK
-
GROUND FLOOR PLAN
Most visited
retail shops (like
Pantaloons, Food
bazaar, ) are
located in front
for better pick
and drop of
items.
Services
offered:
a. Car wash
b. Privileged
parking for
senior
citizens
c. Valet parking
d. Taxi services
e. Kids zone
area
f. Hotel facility
g. Cinemas
h. Food Court
i. Open plaza
j. Weekly
markets
-
FIRST FLOOR PLAN On first floor,
kids oriented
area like mother
care is provided.
Pantaloons is
given in front as
most visited
retail shop.
Multiplex
cinemas are
accessed through
this floor.
SAKET
Multiplex have 6
cinemas
consisting of 2
Gold class
cinemas catering
high net worthy
individuals and
families.
-
SECOND FLOOR PLAN
On second
floor, FOOD
COURT, Several
dining spaces
with open
rooftops seating
and Hangout
space is
provided.
4 rest cinemas
are provided on
this floor.
-
PRINCIPLES OF DESIGN
Balanced plan
Contrast in color, shape and height
Rhythm in elevation
-
RELATION OF SITE TO ITS SURROUNDINGS
The
surroundings to
Saket District
Center is mostly
residential,
some of
commercial,
green spaces,
and public area.
DISTRICT CENTRE , SAKET , NEW
DELHI
-
RELATION OF DESIGN TO THE CLIMATE
-
LANDSCAPING
There is also a outdoor open plaza, Sanskriti, for art festivals, fairs,
exhibitions, performances, and al fresco dining. The plaza is
landscaped extensively in timber, water, stone and steel and has an openair amphitheater, along with trees and water features.
-
BUILDING MATERIAL USED
The entire complex is finished with combination of granite, composite
metallic cladding, Acrylic paint and structural glazing. The lower levels
of the building have been given a more transparent look with large
glazed part being offered to foyer/food court/retail. This has been
done also keeping in mind the commercial aspect for shops to have
maximum frontage and making the shops more visible and lively for
the crowd visiting the building.
The lower levels glazing is treated with granite bands making a striking bold impression
on the lower shopping level and also relates itself with the mall elevation.
-
1.Type of the Construction : RCC Frame structure.
2. External Finish Cladding -Granite, Texture paints, Composite metal.
3. Internal Wall Finish for- Plaster with desired paint finish, ceramic tiles the toilet.
4. Flooring : Marble, Granite Slabs, Vitrified Tiles.
5. Doors : Shutters of ply with TW frames and fire proof wherever required.
6. Windows : Aluminium Sections
WASH BASINS WITH GRANITE
TOP
-
ARCHITECTURAL LANGUAGE : MODERNISM
The term is often applied to the modernist movement at the turn of 20th
century. Using the principles of architecture design with rapid
technological advancements is the modernism. The concept of
modernism is a central theme in the efforts of 20th century modern
architecture. After the second world war, many architects continued the
modern architectural style for institutional and corporate buildings.
Some common themes of modern architecture includes:
Form follows function.
Simplicity and clarity of forms.
Visual emphasis on horizontal and vertical lines.
-
SERVICES
Fire fighting
Fire sprinkler system
It is an active fire protection measure, consisting of a water supply system , providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically only used in factories and large commercial buildings, home and small building systems are now available at a cost-effective price.
FIRE SPRINKLERS
-
Fire hose reel
system
The length of a fully extended fire
hose is 36 meters with a diameter
of 19mm (outside diameter). A
control nozzle attached to the
end of the hose enables the
operator to control the direction
and flow of water to the fire. All
fire hose reels come with a
plastic or solid brass hose reel
nozzle and mounting bracket.
FIRE HOSREEL BOX
INSIDE MALL
FIRE HOSE BOX OUTSIDE
MALL
-
FIRE EXTINGUISHER
A fire extinguisher is an active fire protection device used to extinguish or control small fires, often in emergency situations. Typically, a fire extinguisher consists of a hand-held cylindrical pressure vessel containing an agent which can be discharged to extinguish a fire.
-
HVAC
HVAC (Heating, Ventilating, and Air Conditioning) refers to technology of indoor or automotive environmental comfort. HVAC system design is a major sub discipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers).
HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and healthy building conditions are regulated with temperature and humidity.
AC DUCTING
-
6 systems are
provided for air
conditioning.
One system has
capacity of 600kt.
The capacity if hvac
such that in 1hour 6
quintal can be
freeze together.
Hvav after a period
of time gets
enormously heated
so to overcome this
situation
condensers are
used.
-
POWER BACKUP
POWER
TRANSEFAR
MER AREA
Generally 220v electricity is supplied
for household
purposes. same is in
the case of shops .but
in case of high voltage region 440v electricity
is required. For
example:- pumps etc.
Failure of transformer
lead to use of generators.
-
PHYSICALLY DISABLED FEATURES
APPROPRIATE RAMPS ARE
PROVIDED WITH
APPROPRIATE
RAILINGS.
SEPRATE TOILETS ARE
PROVIDED FOR
PHYSICALLY
CHALLENGED PEOPLE
ON EACH FLOOR.
-
PARKING
3 level basement parking
6000MM
CAR PARKING:1860MMX4340
RAMPS TO UPPER FLOORS
SLOPE 1:10
4960MM
CONCRETE TILE FLOORING
DRAINAGE
-
PARKING
PRIVELEGED PARKING FOR
DIFFERENTLY ABLED
PERSONS,SENIOR
CITIZENS,PREGNANT WOMEN
2500MM
5000MM
TWO WHEELER PARKING:
620X1550
-
STRUCTURAL COMPONENT
FRAMED STRUCTURE
COLUMN :600X600
-
STRUCTURAL COMPONENT
6000MM
80
00
MM
GRID SYSTEM
BEAM 600X600
-
SITE PLAN
-
SERVICES
STP :90 % WATER TREATED AND USED FOR LANDSCAPING AND FLUSHING
FIRE ROOM SIZE :89 FEET X 28 FEET, AREA:2500 SQ. FT
FIRE TANKS: 2 TANKS 225KL BASEMENT
OVERHEAD FIRE TANK: 130 KL
RAW WATER TANK :175 KL
SEWAGE TANK :125KL
DRINKING WATER TANK: 125KL (2 NO.)
HILTON
DOMESTIC
RAW WATER TANK:100 KL
SEWAGE TANK:65KL
DRINKING WATER TANK:65KL
FIRE TANK:25KL(OVERHEAD NO BASEMENT
BOILER ROOM SIZE:37 FEETX22 FEET
SALT CHARGE ROOM (STORAGE):40 FEETX 60 FEET
-
SERVICE
SERVICE LINES
YELLOW:GAS
SKY BLUE: AC
GREEN: WATER(DRINKING)
RED: FIRE
BLACK :SEWAGE
PARKING:
2 ENTRY,2 EXITS , RAMP WIDTH 8M
ELEVATOR LOBBY:2.5MX6.2M
OFFICE
2 LIFTS FOR OFFICE
4 PER BLOCK, 2 SERVICE LIFTS
CORRIDOR:4 FEET 9 INCH
DISTANCE BETWEEN FIRE STAIRCASES:73 FEET 9 INCHES
LIFT LOBBY :3M X 5M
-
SERVICES
I HIGH TENSION ROOM
3 TRANSFORMER ROOM :11000V
SIZE:17 FEET X 23 FEET
ELECTRICAL ROOM :2 NOS SIZE:10 FEET X 15 FEET
AHU ROOM:18 FEET X 27.5 FEET
SERVICE AREA: LIFTS +STAIRS=23 FEET X 27.5 FEET
HOTEL(SEVELTE):
G+5,82 ROOMS
PARKING: 3000
2 FIRE EXITS,2 GUEST LIFT , 1 SERVICE LIFT
2 ENTRIES / EXITS FOR THE HOTEL
OFFICE
2 BASEMENT :100 PARKING
SERVICES IN BASEMENT
G+6
OPEN AIR THEATRE:45 FEET X 20 FEET
-
TOILETS SHOPPING MALL
-
FIRE EXIT PLAN FIRE STAIRCASES DISTANCE
22.2M