12 tee with (3) 4 return nozzle accelerator nozzleriverflowpumps.com/lazyriver/lazy river con...

6
CONSTRUCTION GUIDE LAZY RIVER PUMP SYSTEM PRELIMINARY SYSTEM LAYOUT 1 1 2 3 3 PUMP LOCATION PUMP LOCATION LAZY RIVER 1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN) PRELIMINARY SITE LAYOUT AND PUMP LOCATION 2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE %$6(' 21 )$&725< ),77,1*6 68&+ $6 (/%2:6 21/< 527$7( 3803 TEE TO MEET RETURN PIPE ANGLE. 3 DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS (/%2:6 21/<527$7( 68&7,21 (/%2: $6 1(('(' 72 0((7 SUCTION PIPING ANGLE. NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE. PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING SYSTEM LAYOUT. 4 DIG 4' WIDE X 4' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT 4 4 4 4 12" TEE WITH (3) 4" RETURN NOZZLE 10" OR 12" PIPE RETURN WITH ACCELERATOR NOZZLE 4'-0" 4'-0" PAGE 1 OF 6

Upload: others

Post on 21-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

33.0°

1

4

7

.0

°

4

5

.

0

°

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PRELIMINARY SYSTEM LAYOUT

33.0°

1

1

2

3

3

PUMP LOCATION

PUMP LOCATION

LAZY RIVER

1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN)

PRELIMINARY SITE LAYOUT AND PUMP LOCATION

2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE

BASED ON FACTORY FITTINGS SUCH AS 11.25°, 22.5°, 45°, 90° ELBOWS ONLY. ROTATE PUMP

TEE TO MEET RETURN PIPE ANGLE.

3 DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION

OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS

11.25°, 22.5°, 45°, 90° ELBOWS ONLY.ROTATE 12" SUCTION 90° ELBOW AS NEEDED TO MEET

SUCTION PIPING ANGLE.

NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING

REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT

IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE.

PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING

SYSTEM LAYOUT.

4

5

.

0

°

4 DIG 4' WIDE X 4' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT

4

4

4

4

12" TEE WITH

(3) 4" RETURN NOZZLE

10" OR 12" PIPE RETURN WITH

ACCELERATOR NOZZLE

4

'

-

0

"

4

'

-

0

"

PAGE

1 OF 6

Page 2: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

10

"

3'-0

" T

O 4

'-0

"

1'-3

"

2"

4"

1'-3

1

2

"

2"

4"

1'-3

1

2

"

PIPING INSTALLATION

4

5

.

0

°

4

5

.

0

°

10

"

3'-6

" T

O 4

'-0

"

2"

4"

10

1

2

"

22.5°

22.5°

2"

4"

10

1

2

"

1 12" TEE WITH (3) 4" RETURN NOZZLES TO BE SET 10" BELOW WATER LINE TO TOP RETURN

1

2

2

ROTATE PUMP RETURN TEE AS NEEDED TO MEET RETURN PIPING ANGLE

STRAIGHT RETURN PIPE WITH ACCELERATOR NOZZLE IS TO BE SET 10" BELOW WATER LINE TO

TOP OF PIPE

3

PLACE PUMP AND 90° SUCTION FITTING AT APPROPRIATE HEIGHT TO MEET RETURN PIPING

ELEVATION. DRY FIT ALL PIPING FOR PROPER FIT AND ALIGNMENT BEFORE GLUEING IN PLACE.

SUCTION PIPING TO 90° ELBOW IS TO BE PIPED USING ONLY FACTORY FITTINGS SUCH AS 11.25°,

22.5°, 45°, 90° ELBOWS AS NEEDED.

4

DRY FIT ALL PIPING FROM RETURN TO PUMP & FROM PUMP TO SUCTION BOXES BEFORE

GLUEING IN PLACE.

5

6

6

33.0°

1

4

7

.0

°

4

5

.

0

°

4

'

-

0

"

4

'

-

0

"

1

12" TEE WITH

(3) 4" RETURN NOZZLE

10" OR 12" PIPE RETURN WITH

ACCELERATOR NOZZLE

2

44

3 3

7

7

7

POUR 3' X 3' X 4" THICK SLAB 2" BELOW BOTTOM FLANGE FOR PUMP SUPPORT PAD.6

7

7

3'-0

" T

O 4

'-0

"

3'-6

" T

O 4

'-0

"

5

5

55

5

5

55

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

4

4

12" TEE WITH

(3) 4" RETURN NOZZLE

10" OR 12" PIPE RETURN WITH

ACCELERATOR NOZZLE

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

2 OF 6

REFER TO IMAGE 5 ON PG. 4

REFER TO IMAGE 2 & 4 ON PG. 4

REFER TO IMAGE

2 & 4 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

10" OR 12" PIPE RETURN

Page 3: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

TOP

FRONT SIDE

DUAL SUCTION

GUNITE

APPLICATION

FRONT SIDE

TOP

12 X 5

ACCLERATOR

NOZZLE

10 X 4

ACCLERATOR

NOZZLE

FRONT BACK

TOP

12" TEE

WITH (3) 4"

RETURNS

TOP

FRONT SIDE

VARIABLE SPEED

DRIVE

TOP

FRONT SIDE

VARIABLE SPEED

DRIVE COVER

IN PIPE

IN PIPE

OF 63

RIVERFLOW PUMP

REFER TO IMAGE

1,3,5 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

REFER TO IMAGE

2,4,5 ON PG. 4

Page 4: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 64

1 2

34

5

Page 5: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 65

1 2

3

4

Page 6: 12 TEE WITH (3) 4 RETURN NOZZLE ACCELERATOR NOZZLEriverflowpumps.com/lazyriver/LAZY RIVER CON DOC-031315.pdf · vertical pump installation scale n.t.s. critical note: this system

WATER LINE

VERTICAL PUMP INSTALLATION

SCALE N.T.S.

CRITICAL NOTE:

THIS SYSTEM IS A FLOODED SUCTION SYSTEM. TO MAINTAIN FLOODED SUCTION

PUMP INSTALLATION MUST ADHERE TO MAXIMUM HEIGHT IN RELATION TO

WATER LINE.

VERTICAL INSTALLATION:

PUMP FLANGE GASKET MUST MEET MAXIMUM HEIGHT AT WATER LINE OR

LOWER. PIPE FITTINGS ARE REQUIRED TO MAINTAIN RETURN @ 10" BELOW

WATER LEVEL. REFER TO SECTIONS AND PLANS FOR PUMP ELEVATION AND

REQUIRED FITTINGS AS PER PROJECT APPLICATION.

12" SUCTION

PIPE FROM

MAIN DRAIN

BOXES

RIVER

BEAM

10" OR 12"

RETURN PIPE

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 66

MAXIMUM PUMP

HEIGHT WITH TOP

OF BOTTOM

FLANGE AT OR

BELOW WATER

LINE