12.heat excanger
DESCRIPTION
Heat ExchangerTRANSCRIPT
![Page 1: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/1.jpg)
Heat Exchanger
Sistem Permesinan
1
References :• Introduction to Marine Engineering
• Marine Auxiliary Machinery• Maritime Engineering Reference
Handbook• Marine engineering
Dedi Budi Purwanto ST.,MT.
![Page 2: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/2.jpg)
Introduction
At different temperature and thermal contact
Transfer thermal energy
Between two or more fluids
Between a solid
surface and a fluid
Between solid
particulates and a fluids
Heat exchanger
Components fluids stream
Single Multiple
Typical applications
Heating (Evaporation)
Cooling (Condensatio
n)
2
![Page 3: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/3.jpg)
Introduction Design consideration:
Corrosion
Fouling
Fluid temperature
Operating pressures
Pressure drop
Viscosity
flow rate
Material of Construction
Cooper
Best heat transfer performance of all metal
High thermal conductivity
Relatively poor corrosion resistance
Brass (an alloy cooper & zinc)
Is stronger than cooper while still retaining high thermal conductivity
Suffer from corrosion
Aluminum
Is a lightweight metal and has high heat transfer efficiency at a comparatively low cost
corrosion resistance
Stainless steel
Excellent corrosion resistance
Lower heat transfer efficiency
expensive
3
![Page 4: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/4.jpg)
Types of Heat Exchangers According to the heat transfer
process
In indirect contact heat transfer
In direct contact heat transfer
According to construction
the heat exchanger may incorporate shell & tube, plated, spiral, or air-cooled construction.
According to flow arrangements
the heat exchanger may be either single pass or multi-pass. It may incorporate cross-flow, counter-flow, or co-current flow
According to the number of fluids
the heat exchanger may incorporate two, three, or more than three heat transfer fluids in the system.
According to heat transfer mechanism
the heat exchanger uses single-phase convection, two-phase convection, and/or radioactive heat transfer on each side of the exchange
According to process function
Condenser, chiller, heater, coolers
4
![Page 5: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/5.jpg)
According to Transfer processes
Wet surface direct evaporative coolers typically use pump circulating water system to keep the media wet
In a typically indirect evaporation air cooler, the essential element is a heat exchanger in which dry air contact heat exchange surface whose other sides are cooled evaporative
5
![Page 6: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/6.jpg)
According to Construction
6
![Page 7: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/7.jpg)
Tubular heat exchanger The configuration give a large surface area in a small volume
Flexibility design : Easily by changing the tube diameter, length and arrangement
Design for high pressure
Easily cleaned
7
![Page 8: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/8.jpg)
Tube pattern
Recommended tube pitch (distance between tube centre) is 1.25 times the tube outside diameter
Tube arrangement
8
![Page 9: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/9.jpg)
Tube Design1. Finned tube2. Surface tube3. Straight tube4. U – tube
9
![Page 10: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/10.jpg)
Shell type (pass arrangement)
a. One pass shell (E shell)
b. Split flow (G shell)
c. Divided shell (J shell)
d. Two pass shell with longitudinal baffle (F shell)
e. Double split flow (H shell)
10
![Page 11: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/11.jpg)
Baffle
The choice baffle type, spacing, and cut is determinate largely by flow rate, desired heat transfer rate, allowable pressure drop, tube support
Flow induced vibration Spacing used ranged from 0.2 to 1.0 shell diameter
Optimum spacing will usually be between 0.3 to 0.5 time the shell diameter
11
![Page 12: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/12.jpg)
Plate heat exchanger Cannot accommodate very high pressure, temperature.
Lower fouling due to high turbulence in the exchanger
Higher heat transfer efficiency
Material selection is critical due to the thin wall thicknesses
They can easily be taken apart into their individual component for cleaning, inspection, and maintenance
12
![Page 13: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/13.jpg)
There are three main types of plated heat exchangers
plate and frame heat exchangers,
consist of a number of corrugated metal plates in mutual contact
spiral plate heat exchangers, and
are a type of welded plate heat exchanger with two parallel curved (spiral shaped) metal plates.
These plates create extremely high turbulent flow in a counter-current pattern. can be used with high-viscosity fluids.
plate coil heat exchangers.
hybrid of tube heat exchangers and plate heat exchangers.
13
![Page 14: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/14.jpg)
14
![Page 15: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/15.jpg)
Extended surface heat exchanger Large heat transfer surface area
Type
Tube fin
Plate fin
15
![Page 16: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/16.jpg)
Regenerative Is a storage type heat exchanger
16
![Page 17: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/17.jpg)
According to Flow Arrangement Particular flow arrangement is dependent:
Required exchanger affectivities
Available pressure drop
Minimum & maximum velocity
Allowable thermal stresses,
Temperature levels
Piping considerations
17
![Page 18: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/18.jpg)
Single pass exchanger Counter flow
Parallel flow
18
![Page 19: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/19.jpg)
Single pass exchanger Cross flow
19
![Page 20: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/20.jpg)
Multi pass exchanger Multiphase cross flow
Multiphase shell & tubes
Multiphase plate
20
![Page 21: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/21.jpg)
According to Process Function
21
![Page 22: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/22.jpg)
Chiller Chilled water temperatures can
range from 35 to 45 degrees Fahrenheit (1.5 to 7 degrees Celsius)
22
![Page 23: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/23.jpg)
Typical water-cooled chiller system Indirect water-side economizer
23
![Page 24: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/24.jpg)
24
Condenser condensing the exhaust steam
from a steam and transferring the waste heat away from the power station.
The function of the condenser is to condense exhaust steam from the steam turbine by rejecting the heat of vaporization to the cooling water passing through the condenser
![Page 25: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/25.jpg)
25
Types of condensers
a) air-cooled
b) water-cooled
c) evaporative
![Page 26: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/26.jpg)
26
Air cooled heat exchangers may be either forced draft or induced draft.
Forced draft heat exchangers "force" or push air through the unit by installing fans at the inlet below the tube bundle
Induced draft heat exchangers pull air through the unit by installing fans at the outlet above the tube bundle
Coolers
![Page 27: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/27.jpg)
Cathodic Protection Reducing the corrosion rate of a metal.
The principle is based on “Supplying electrons to the base material”
Material cathodic
Zinc
Aluminium
Magnesium
27
![Page 28: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/28.jpg)
Aplikasi di Kapal Lubricating Oil Cooler
28
![Page 29: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/29.jpg)
29
FO & LO heater
![Page 30: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/30.jpg)
30
Hot Water Heater
![Page 31: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/31.jpg)
31
![Page 32: 12.Heat Excanger](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf8f18550346703b98e42e/html5/thumbnails/32.jpg)