12v 80ah lvl80-12 - liven battery...12v 80ah lvl80-12 lvl series vrla battery specification: cells...

2
F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR 1.60V 196.50 146.50 84.78 49.75 29.81 21.89 17.78 15.01 10.03 8.53 4.37 1.65V 190.70 142.70 82.92 48.83 29.37 21.60 17.56 14.83 9.93 8.45 4.34 1.70V 183.00 137.60 80.46 47.61 28.79 21.21 17.26 14.60 9.79 8.34 4.29 1.75V 173.00 131.00 77.24 46.01 28.02 20.69 16.87 14.30 9.61 8.20 4.23 1.80V 160.30 122.60 73.06 43.91 27.01 20.02 16.36 13.89 9.37 8.00 4.15 1.85V 144.50 111.90 67.73 41.21 25.70 19.13 15.68 13.36 9.06 7.75 4.04 LVL80-12 12V 80AH LVL series VRLA battery Specification: www.liven-battery.com Cells Per Unit 6 Voltage Per Unit 12V Nominal Capacity 80.0Ah @10hour-rate to 1.80V per cell @25°C Weight Approx. 24.0Kg ±2% (52.91lbs) Internal Resistance Approx. 5.5mΩ Terminal R6.0 Max. Discharge Current 800A (5sec) Design Life 12 years (Float charging) Eurobat (20ºC): 10-12 years Long Life Recommended Maximum Charging Current 24.0A Standby Use Voltage 13.8V~13.9V @ 25°C Temperature Compensation: -3mV/°C/Cell Cycle Use Voltage 14.6V~14.8V @ 25°C Temperature Compensation: -4mV/°C/Cell Operating Temperature Range Discharge: -15°C~50°C Charge: -10°C~45°C Storage: -15°C~50°C Normal Operating Temperature Range 25°C±5°C Self Discharge LIVEN Valve Regulated Lead Acid (VRLA) batteries can be stored for up to 6 months at 25°C and then recharging is recommended. Monthly Self-discharge ratio is less than 3% at 25°C.Please charge batteries before using. Container Material A.B.S. UL94-HB, UL94-V0 Optional. Technical Drawing: LIVEN LVL Series AGM (Absorbent Glass Material) technology with gas recombination. VRLA (Valve Regulated Lead Acid Battery). Maintenance-Free Sealed Lead Acid Battery. Battery with 12 years design life in float service. Cycle use 1: Up to 260 cycles at 100% DOD. Cycle use 2: Up to 500 cycles at 50% DOD. Application: Length 350±1.5mm (13.8in) Width 167±1.5mm (6.57in) Height 182±1.5mm (7.17in) Total Height 182±1.5mm (7.17in) Dimensions: Constant Current Discharge (CC, Unit: A) at 25ºC (77ºF) Constant Power Discharge (CP, Unit: W/Battery) at 25ºC (77ºF) Telecommunications Uninterrupted Power Supplies Medical equipments Emergency backup power supply Alarm and security system Communication power supply DC power supply F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR 1.60V 2034.60 1560.00 937.80 566.52 344.04 254.58 207.84 176.16 119.28 102.06 52.44 1.65V 2026.20 1551.00 930.60 561.90 341.46 252.72 206.34 175.02 118.44 101.34 52.14 1.70V 1966.20 1509.00 908.40 549.78 335.76 248.82 203.34 172.68 117.00 100.08 51.60 1.75V 1893.00 1458.00 880.80 533.94 328.32 243.84 199.50 169.62 115.02 98.52 50.94 1.80V 1784.40 1383.00 841.80 512.04 318.12 236.76 194.10 165.36 112.44 96.30 49.98 1.85V 1636.20 1280.40 787.80 483.96 304.26 227.34 186.84 159.60 108.96 93.42 48.72

Upload: others

Post on 26-Jan-2021

12 views

Category:

Documents


0 download

TRANSCRIPT

  • F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR1.60V 196.50 146.50 84.78 49.75 29.81 21.89 17.78 15.01 10.03 8.53 4.371.65V 190.70 142.70 82.92 48.83 29.37 21.60 17.56 14.83 9.93 8.45 4.341.70V 183.00 137.60 80.46 47.61 28.79 21.21 17.26 14.60 9.79 8.34 4.291.75V 173.00 131.00 77.24 46.01 28.02 20.69 16.87 14.30 9.61 8.20 4.231.80V 160.30 122.60 73.06 43.91 27.01 20.02 16.36 13.89 9.37 8.00 4.151.85V 144.50 111.90 67.73 41.21 25.70 19.13 15.68 13.36 9.06 7.75 4.04

    LVL80-1212V 80AHLVL series VRLA battery

    Specification:

    www.liven-battery.com

    Cells Per Unit 6

    Voltage Per Unit 12V

    Nominal Capacity 80.0Ah @10hour-rate to 1.80V per cell @25°C

    Weight Approx. 24.0Kg ±2% (52.91lbs)

    Internal Resistance Approx. 5.5mΩ

    Terminal R6.0

    Max. Discharge Current 800A (5sec)

    Design Life 12 years (Float charging) Eurobat (20ºC): 10-12 years Long Life

    Recommended Maximum Charging Current 24.0A

    Standby Use Voltage 13.8V~13.9V @ 25°C Temperature Compensation: -3mV/°C/Cell

    Cycle Use Voltage 14.6V~14.8V @ 25°C Temperature Compensation: -4mV/°C/Cell

    Operating Temperature RangeDischarge: -15°C~50°C Charge: -10°C~45°C Storage: -15°C~50°C

    Normal Operating Temperature Range 25°C±5°C

    Self Discharge

    LIVEN Valve Regulated Lead Acid (VRLA) batteries can be stored for up to 6 months at 25°C and then recharging is recommended. Monthly Self-discharge ratio is less than 3% at 25°C.Please charge batteries before using.

    Container Material A.B.S. UL94-HB, UL94-V0 Optional.

    Technical Drawing:

    LIVEN LVL Series

    AGM (Absorbent Glass Material) technology with gas recombination. VRLA (Valve Regulated Lead Acid Battery). Maintenance-Free Sealed Lead Acid Battery.Battery with 12 years design life in float service.

    Cycle use 1: Up to 260 cycles at 100% DOD. Cycle use 2: Up to 500 cycles at 50% DOD.

    Application:

    Length 350±1.5mm (13.8in)Width 167±1.5mm (6.57in)Height 182±1.5mm (7.17in)Total Height 182±1.5mm (7.17in)

    Dimensions:

    Constant Current Discharge (CC, Unit: A) at 25ºC (77ºF)

    Constant Power Discharge (CP, Unit: W/Battery) at 25ºC (77ºF)

    • Telecommunications

    • Uninterrupted Power Supplies

    • Medical equipments

    • Emergency backup power supply

    • Alarm and security system

    • Communication power supply

    • DC power supply

    F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR1.60V 2034.60 1560.00 937.80 566.52 344.04 254.58 207.84 176.16 119.28 102.06 52.441.65V 2026.20 1551.00 930.60 561.90 341.46 252.72 206.34 175.02 118.44 101.34 52.141.70V 1966.20 1509.00 908.40 549.78 335.76 248.82 203.34 172.68 117.00 100.08 51.601.75V 1893.00 1458.00 880.80 533.94 328.32 243.84 199.50 169.62 115.02 98.52 50.941.80V 1784.40 1383.00 841.80 512.04 318.12 236.76 194.10 165.36 112.44 96.30 49.981.85V 1636.20 1280.40 787.80 483.96 304.26 227.34 186.84 159.60 108.96 93.42 48.72

  • www.liven-battery.com

    12V 80AH LVL series VRLA LVL80-12

    Discharge Characteristics Curve Charge Characteristic Curve For Standby Use

    Cycle Life In Relation To Depth Of Discharge Relationship Between Charging Voltage And Temperature

    Temperature Effects On Capacity Storage Characteristics

    Effect Of Temperature On Long Term Life Life Characteristics Of Standby Use

    V02 20/07

    (Not

    e) A

    ll ab

    ove

    info

    rmat

    ion

    shal

    l be

    chan

    ged

    with

    out p

    rior n

    otic

    e, L

    IVE

    N B

    atte

    ry re

    serv

    es th

    e rig

    ht to

    exp

    lain

    and

    upd

    ate

    the

    late

    st in

    form

    atio

    n.

    LVL80-12LVL80-12