13.0 revised renderings
TRANSCRIPT
e howell st
belmont ave
boylston ave
olive st e
13.0 REVISED Renderings
The SW on E HOWELL ST. Vertical board & batten charred cedar bookended by large expanses of operable glazing runs up the length of the main facade. At street level a metal fence continues on top of a landscaped wall along the front-yard property line. Rose vines grow on the fence to screen private from public, and just behind the wall lives a small urban garden.
611 E Howell St Seattle WA 98112 - REVISED Design Recommendation Packet - DPD Project #3016271 Pg. 20
e howell st
belmont ave
boylston ave
olive st e
The E HOWELL ST ENTRY is delineated by an antique lantern below a simple, vertically oriented building sign. An illuminated, permeable brick-paved entry courtyard will be visible from the sidewalk through a secure, semi-transparent entry gate. A metal fence continues on top of a landscaped wall along the front-yard property line. Rose vines grow on the fence to screen private from public, and just behind the wall lives a small urban garden.
13.0 REVISED Renderings
611 E Howell St Seattle WA 98112 - REVISED Design Recommendation Packet - DPD Project #3016271 Pg. 21
e howell st
belmont ave
boylston ave
olive st e
E HOWELL ST ENTRY COURTYARD The Eastward shift of the proposed building creates a comfortable space between the proposed building and The Granada Apartments. This space serves as the entry courtyard for the proposed building and will be visible from Howell Street through a transparent gate, adding a sense of openness to the street.
13.0 REVISED Renderings
611 E Howell St Seattle WA 98112 - REVISED Design Recommendation Packet - DPD Project #3016271 Pg. 23
4
C
1
3
2
BA
11'-1 3/4"
11'-1 3/4" 11'-1 3/4"
11'-1 3/4" 11'-1 3/4"
7'-2"7'-2"
7'-2"7'-2"
11'-1 3/4"
7'-2"7'-2"
7'-2"7'-2"
EQEQ
EQ
LED LIGHTING TAPEBELOW UPPER KITCHEN
CABINETS, TYP
SDSD
SDSD
SD
EQ EQ
9'-2
7/8"
EQ EQ
CENTEREDON SINK,TYP
EQEQ
SDSD
SDSD
CENTEREDON SINK,
TYP
KITCHEN202C
KITCHEN201C
WC201B
WC202B
FOYER202A
FOYER201A
STORAGEG200B
LOBBY200A
STAIRG100B
FOYER204A
FOYER203A
WC204B
WC203B
LIVING /SLEEPING
203D
LIVING /SLEEPING
202D
LIVING /SLEEPING
201D
LIVING /SLEEPING
204D
KITCHEN203C
KITCHEN204C
LAUNDRY200C
SEE 2/A130 FORCEILING INFORMATIONON HIGH CEILING
SEE 2/A130 FORCEILING INFORMATIONON HIGH CEILING
8x10 GLULAM PERSTRUCTURAL
8x10 GLULAM PERSTRUCTURAL
SEE 2/A130 FORCEILING INFORMATION
ON HIGH CEILING
SEE 2/A130 FORCEILINGINFORMATION ONHIGH CEILING
4
C
1
3
2
BA
8'-3 3/4" 8'-3 3/4"
7'-2"
7'-2"
7'-2"
8'-3 3/4"
8'-3 3/4"
8'-3 3/4"8'-3 3/4"
EQEQ
EQ EQ
SEE 5/A-5041'-11"
EQ EQ
EQEQ
EQ EQ
LED LIGHTING TAPEBELOW UPPER KITCHEN
CABINETS, TYP
LED LIGHTINGTAPE
WITHIN STEELPICTURE RAIL
SEE 1/A-501
LED LIGHTING TAPEWITHIN STEEL PICTURE RAIL
SEE 1/A-501
EQEQ
LED LIGHTING TAPEBEHIND WALL DIFFUSERVERTICALLY ORIENTED
SD
SD
SD
SD
CENTERED ONSINK, TYP
SD
SD
SD
CENTEREDON SINK,
TYP
SD
SD
WALL-MOUNTED
SD
EQ EQ
EQEQ
EQEQ
EQEQ
EQ EQ
BASEMENTBICYCLE /STORAGEG100G
BASEMENTMECHANICAL /ELECTRICAL
G100F
MAIN LOBBYG100A
MAILG100C
LAUNDRY/STORAGEG100H
WCG102B
FOYERG102A
WCG101B
TYPE BACCESIBLE
UNITG102D
KITCHENG102C
STAIRG100B
LIVING /SLEEPINGG101D
4
C
1
3
2
BA
7'-2"7'-2"
7'-2"7'-2" LED LIGHTING TAPEBELOW UPPER KITCHENCABINETS, TYP
SD
SD
SD
SD
SDSD
SDSDCENTEREDON SINK,TYP
EQEQ
EQEQ
EQ EQ
EQ EQ
EQEQ
EQ
LOBBY500A
STORAGE500B
LAUNDRY500C
WC501B
WC502B
KITCHEN502C
KITCHEN501C
FOYER501A
FOYER502A
LIVING /SLEEPING
502D
LIVING /SLEEPING
501D
BENT STEELAWNING
SEE 2/A130 FORCEILING INFORMATIONON HIGH CEILING
8x10 GLULAM PERSTRUCTURAL
Job No.:
Drawn By:
Checked by:
Filename:
Date:
1
0
S
O
U
T
H
C
E
D
A
R ,
S
P
O
K
A
N
E ,
W
A .
9
9
2
0
4T
E
L E
P
H
O
N E
:
( 5
0
9 )
8 3
8
-
8 6
8
1
F A
X :
(
5 0
9
) 8
3
8 -
2
1
9 4
REVISIONS
C:\L
ocal
Rev
it Fi
les\
2131
7 AR
BOL
LOFT
S-C
ENTR
AL-R
14 fo
r REC
PAC
KET
(DET
ATC
HED
)_an
ewm
an.rv
t
21317
AN/YL
LH
A-131
12/15/2014
REFLECTEDCEILING PLANS
THE
ARBO
L LO
FTS
611 E
How
ell S
t Sea
ttle,
WA
9812
2
MUP CORRECTION CYCLE #2
SCALE: 1/4" = 1'-0"2 RCP - Levels 2, 3, 4, 5SCALE: 1/4" = 1'-0"1 RCP - Ground
SCALE: 1/4" = 1'-0"3 RCP - Levels 5 & Roof
# Date Description
2 12/3/14 Revision 2
2
2
DW
REF. REF.
DW
WD
4
C
1
3
2
BA
A-2011
A-2002
1A-300
1A-300
2A-300
2A-300
2A-301
2A-301
3A-301
3A-301
1A-301
1A-301
IPE PALETTE ROOFDECKING OVER
MEMBRANE ROOFING
W1A
IW3
W1A
W1B
W2
W1B
W1A
WC502B
WC501BFOYER
502AFOYER501A
KITCHEN501C
KITCHEN502C
LIVING /SLEEPING
502D
LOBBY500A
STAIRG100B
ROOF DECK700C
LAUNDRY500C
LIVING /SLEEPING
501D
1/4" : 1'
WALL MOUNTEDRADIATOR
BENT STEELAWNING
STEPS UP
1'-0"
6'-0
"
HOSEBIBB
EQEQ
EQEQ
EQ
EQ EQ EQ EQ EQ
AGS STAINLESS INC.CLEARVIEW RAILINGW/ ROUND TOP RAILFACE-MOUNTED TO
INSIDE OF PARAPET(SEE A-501)
SHIP'S LADDERTO STORAGE AREA, TYP.
DNROOF HATCH
TYP. HANDRAIL36" AFF EXTEND12" PASS UPPERAND LOWER TREAD
CONT. HANDRAILAT CENTER WALL
A-5068
TYP
A-5068
TYP
42"H GUARDRAIL
A-5067
STORAGE500B
2'-0
"2'-6
"1'-
2 1/2"
1/4" : 1'
4
C
1
3
2
BA
A-2001
A-2011
A-2002
1A-300
1A-300
2A-300
2A-300
2A-301
2A-301
3A-301
3A-301
1/4" : 1'
18" x 18" ROOF HATCH
FALL ARRESTANCHOR, TYP.
3'-4
"
3'-0"
"SOLAR READINESS ZONE"PER 2012 SEATTLE
COMMERCIAL ENERGY CODESECTION C410
(40% OF FREE ROOF AREA)
ACTIVE SOLAR PANELSPER 2012 SEATTLECOMMERCIAL ENERGYCODE SECTION C410
ROOF EXHAUST FANSPER MECHANICAL
3'-0"
SPF PER MECH
R100
G-001A7
TO P
ROP
LINE
SOLA
R P
ANEL
S43'-8 1/8"
SCUPPER ANDCONDUCTOR HEAD PIPE PENETRATIONS
THROUGH ROOF
EQUIP. CURB W/ HIGH -SIDE CRICKET
NOTE: LOCATIONS ARE APPROXIMATE, CONTRACTOR TO PROVIDE LAYOUTFOR ARCHITECT'S APPROVAL PRIOR TO INSTALLATION.
ROOF PLAN LEGEND
1. REFERENCE & COORDINATE W/ MECHANICAL FOR TYPES & LOCATIONS OFEQUIPMENT CURBS & PENETRATION DETAILS.
2. NO ROOF PENETRATION BEYOND THOSE SHOWN IN DOCUMENTS W/O PRIORAUTHORIZATION FROM ARCHITECT - ASSUME 120 MISC CONDUIT PENETRATIONSOVER & ABOVE THOSE SHOWN, BOTH VERTICAL AND/OR HORIZONTAL.
3. VENT RISERS & EXHAUST SYSTEMS HAVE BEEN LOCATED TO MINIMIZECONTAMINATION OF MECHANICAL AIR INTAKE. THE GENERAL CONTRACTORSHALL BE RESPONSIBLE FOR FINAL COORDINATION. GC SHALL PROVIDECOORDINATION SHOP DRAWINGS.
4. AS PART OF THE ARCHITECT'S REVIEW OF COORDINATION SHOP DRAWINGS,THE ARCHITECT RESERVES THE RIGHT TO ADJUST FINAL PENETRATIONLOCATIONS TO WITHING 5' FEET OF ITEM SHOWN.
5. UNO, ROOFING ASSEMBLY IS TYPE R1. REFER TO DETAIL 4/A-530 FOREDGE CONDITION TYP. AT ALL WALLS, PARAPETS, CURBS, AND SLEEPERS.
GENERAL NOTES
CRICKET VALLEY, SLOPEDTO DRAIN AT MIN. 1/4"/1'-0"
CRICKET, SLOPE TO DRAINAT 1/8"/1'-0"
FIXED ROOF LADDER,REFER TO DETAIL
REFRIGERANT PIPINGPENETRATION ANDENCLOSURE
MIN.1' - 0"
ROOF DRAIN
CAGE LIGHTVXBR100DG
FALL ARREST ANCHORLOCATION - REFER TODETAIL 7/A-531
ROOF ACCESS HATCH
Job No.:
Drawn By:
Checked by:
Filename:
Date:
1
0
S
O
U
T
H
C
E
D
A
R ,
S
P
O
K
A
N
E ,
W
A .
9
9
2
0
4T
E
L E
P
H
O
N E
:
( 5
0
9 )
8 3
8
-
8 6
8
1
F A
X :
(
5 0
9
) 8
3
8 -
2
1
9 4
REVISIONS
21317
AN/YL
LH
A-103
12/15/2014
FLOOR PLANS -LEVEL 7 & ROOFPLAN
THE
ARBO
L LO
FTS
611 E
How
ell S
t Sea
ttle,
WA
9812
2
MUP CORRECTION CYCLE #2
SCALE: 1/4" = 1'-0"
Level 5 - Floor PlanSCALE: 1/4" = 1'-0"
Roof Plan
# Date Description
2 12/3/14 Revision 2
2
2
14.0 REVISED Exterior Lighting
Festoon / Cafe LightsSuspended overhead
Extra largeMission Inn LanternWall-mounted
Gooseneck Barn LightsWall-mounted
Cage LightsWall-mounted
1
2
3
4