1350 ashley river road

8
WEST ASHLEY, SC 29407 1350 ASHLEY RIVER ROAD MARK MATTISON, II CCIM, SIOR +1 843 437 1545 [email protected] WWW.BRIDGE-COMMERCIAL.COM WILL CROWELL +1 504 975 1099 [email protected] CLASS A OFFICE SPACE FOR LEASE 4 PARKING SPACES / 1,000 SF NEARBY AMENITIES QUICK ACCESS TO DOWNTOWN 2,660 RSF - 6,443 RSF AVAILABLE COLBY FARMER +1 978 998 9243 [email protected]

Upload: others

Post on 14-Feb-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

WEST ASHLEY, SC 29407

1350 ASHLEY RIVER ROAD

MARK MATTISON, II CCIM, SIOR+1 843 437 [email protected]

WWW.BRIDGE-COMMERCIAL.COM

WILL CROWELL+1 504 975 [email protected]

CLASS AOFFICE SPACE

FOR LEASE

4 PARKING SPACES / 1,000 SF

NEARBYAMENITIES

QUICK ACCESSTO DOWNTOWN

2,660 RSF -6,443 RSFAVAILABLE

COLBY FARMER+1 978 998 [email protected]

1350 ASHLEY RIVER ROAD

FOLLY RD

FOLLY RD

17

61

LOCATION + NEARBY AMENITIES

Quick access + amenities

WWW.BRIDGE-COMMERCIAL.COM

WEST ASHLEY GREENWAYWEST ASHLEY GREENWAY

17

FOLLY RD

FOLLY RD

RESTAURANTSAl Di LaBlackwood SmokehouseCalifornia DreamingClean JuiceEast Bay DeliHubeeDee’sHome Team BBQJason’s DeliKaminsky’sMellow MushroomMex1Moe’s Southwest GrillNormandy FarmsPanera BreadPearl’s Oyster BarSalty Mike’sStarbucksTCBY

The RoostThe Taco SpotTriangle Char & BarVerdeYe Ole Fashioned

RETAIL/SERVICESAT&TBank of AmericaBarnes & NobleBelk’sBluewater C-StoreCostcoCVSDick’s Sporting GoodsEarth FareF45 GymHalf Moon OutfittersHyLo Fitness

Harris TeeterIn and Out Car WashOrange Theory FitnessPetcoPinnacle FinancialTargetTJ MaxxSouth State BankStaplesUrban NirvanaWest MarineWhole FoodsYoga

HOTELSCambriaFairfield InnHilton Garden InnHoliday Inn Express

LaQuinta InnMariottMariott CourtyardMarriott Residence Inn

OTHER35 Folly Luxury ApartmentsPorter Gaud SchoolRipley Light MarinaWest Ashley GreenwayAshley River Bike-Pedestrian Bridge (Coming 2023)

1350 ASHLEY 1350 ASHLEY RIVER ROADRIVER ROAD

1 mi

1350 ASHLEY 1350 ASHLEY RIVER ROADRIVER ROAD

MT. MT. PLEASANTPLEASANT

DANIELDANIELISLANDISLAND

NORTHNORTHCHARLESTONCHARLESTON

WEST WEST ASHLEYASHLEY

DOWNTOWNDOWNTOWNCHARLESTONCHARLESTON

1350 ASHLEY RIVER ROADEXAMPLE FINISHED SUITEWOW! FIBER INTERNET AVAILABLE

New modern finishes throughout

2

3

1

4

CB D E F G

99''--00"" 1111''--66"" 1111''--55 33//44"" 99''--00""

1122''--

99""

1100''--

00""

2200''--00""

1100''--00""

1144''--00""

2200''--

00""

1155''--00""

WOR

K AR

EA

TELE. RM

SMALL CONFERENCE ROOM

KITC

HEN CONFERENCE ROOM

55''--77 11//44""

2200''--00""

1155''--

44 11//

22""

1122''--00""

99''--66

""99''

--66""

STORAGE

OFFICE OFFICEOFFICE OFFICE

BREAK ROOM/COPY

1100''--

00""1188

''--88""

44''--11

11//22

""

1166''--88 33//44""

BREAK OUT ROOM

OFFICE

1100''--00""

OFFICE

OFFICE

RECEPTION

RECEPTION RECEPTION

A

CONFERENCE ROOM

1144''--66""

LARGE OFFICE

WORK AREA WORK AREA

CONFERENCE ROOM

STORAGE/IT

BREAK ROOM/COPY

1122''--

99""3344

''--77""

1155''--

55""

5522''--77 33//44""

77''--33 11//44"" 1100''--22""

1199''--44"" 1100''--00""

4477''--

99""1155

''--55""

77''--44""

1122''--

1100""

88''--00"" 88''--66 11//44"" 88''--00""

2299''--77 33//44"" 1144''--1111""

4422''--33""

2233''--

55 33//

44""

SUITE 100

SUITE 400

SUITE 200

SUITE 300

SUITE 500 SUITE 600

3/31

/202

0 11

:33:

50 P

M

Jeff Reed

1350 Ashley River Road FLOOR PLAN OPTION 1

1/8" = 1'-0"A505

1 FLOOR PLAN

1350 ASHLEY RIVER ROAD

WWW.BRIDGE-COMMERCIAL.COM

Bridge Commercial makes no guarantees, representations or warranties of any kind, expressed or implied, including warranties of content, accuracy and reliability. Any interested party should do their own research as to the accuracy of the information. Bridge Commercial excludes warranties arising out of this document and excludes all liability for loss and damages arising out of this document.

POTENTIAL DEMISING PLAN: ±2,660 RSF - ±6,443 RSFSUITE 400 - ±2,660 RSFSUITE 500 - ±3,783 RSF

ASHLEY RIVER ROAD

LEASED

LEASED

LEASED

LEASED

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

1350 ASHLEY RIVER ROAD

WWW.BRIDGE-COMMERCIAL.COM

Bridge Commercial makes no guarantees, representations or warranties of any kind, expressed or implied, including warranties of content, accuracy and reliability. Any interested party should do their own research as to the accuracy of the information. Bridge Commercial excludes warranties arising out of this document and excludes all liability for loss and damages arising out of this document.

POTENTIAL DEMISING PLAN: ±2,660 RSF - ±6,443 RSFSUITE 400 - ±2,660 RSFSUITE 500 - ±1,892 RSFSUITE 550 - ±1,892 RSF

ASHLEY RIVER ROAD

SUITE 500SUITE 500

SUITE 400SUITE 400

SUITE 550SUITE 550

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

7'-9 1/2"3'-8"

3'-8"4'-0"

4'-8"4'-0"

3'-9 1/2"9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM

A101

FIRST FLOORPLAN

18034

1350 Ashley River RoadJeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTH N

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

POTE

NTI

AL D

EMIS

ING

WAL

LS

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

LEASED

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

71/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

LEASED

LEASED

LEASED

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

SUITE 500SUITE 500

SUITE 200

SUITE 400SUITE 400

SUITE 450SUITE 450

SUITE 550SUITE 550

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

7'-9 1/2"3'-8"

3'-8"4'-0"

4'-8"4'-0"

3'-9 1/2"9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM

A101

FIRST FLOORPLAN

18034

1350 Ashley River RoadJeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTH N

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

SUITE 300

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

LEASED

SUITE 650

LEASED

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

1350 ASHLEY RIVER ROAD

WWW.BRIDGE-COMMERCIAL.COM

Bridge Commercial makes no guarantees, representations or warranties of any kind, expressed or implied, including warranties of content, accuracy and reliability. Any interested party should do their own research as to the accuracy of the information. Bridge Commercial excludes warranties arising out of this document and excludes all liability for loss and damages arising out of this document.

SUITE 500 - ±1,892 RSF

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

SUITE 500SUITE 500

SUITE 200

SUITE 400SUITE 400

SUITE 450SUITE 450

SUITE 550SUITE 550

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

10'-0"4'-0"

7'-9 1/2"3'-8"

3'-8"4'-0"

4'-8"4'-0"

3'-9 1/2"9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM

A101

FIRST FLOORPLAN

18034

1350 Ashley River RoadJeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTH N

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB -BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB -BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB -BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB -BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1EQ1EQ2EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1SF1SF1SF1SF1SF1

8'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

10'-0"

4'-0"

7'-9 1/2"

3'-8"

3'-8"

4'-0"

4'-8"

4'-0"3'-9 1/2"

9'-5 1/2"

14'-10"

109'-10 1/2"

52'-9"29'-9 1/2"14'-11"

01

01

01

01

01

010101010101

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB -BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB -BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"13'-4"4'-0"4'-8"4'-0"69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

CORRIDOR001

CORRIDOR001

63'-10 1/2"

43'-10 1/4"

52'-7 1/4"8'-0"18'-9 1/4"

21'-1"10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/26/2019 8:32:45 PM A101

FIRST FLOORPLAN

18034

1350 Ashley River Road

Jeff Reed

12.4.2018

PERMIT SET

1350 Ashley River Road,

Charleston SC, 29407

1/8" = 1'-0" A101

1FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

NameOccupancy TypeAreaArea PerOccupantOccupant Load

COREBUSINESS AREA2043 SF100 SF21

SUITE 100BUSINESS AREA2356 SF100 SF24

SUITE 200BUSINESS AREA677 SF100 SF7

SUITE 300BUSINESS AREA922 SF100 SF10

SUITE 400BUSINESS AREA2323 SF100 SF24

SUITE 500BUSINESS AREA3304 SF100 SF34

SUITE 600BUSINESS AREA2498 SF100 SF25145

OCCUPANT LOAD

LEGEND

DESCRIPTIONRENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEMNOT SPRINKLEREDBUILDING AREA14,123 SFNUMBER OF STORIES1 STORYCONSTRUCTION TYPEIII-BSEISMIC DESIGNCATEGORY

D

ZONINGLB - LIMITED BUSINESSFLOOD ZONEXFIRE ALARMNONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No.DescriptionDate

SUITE 300

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

LEASED

SUITE 650

LEASED

1350 ASHLEY RIVER ROAD

WWW.BRIDGE-COMMERCIAL.COM

Bridge Commercial makes no guarantees, representations or warranties of any kind, expressed or implied, including warranties of content, accuracy and reliability. Any interested party should do their own research as to the accuracy of the information. Bridge Commercial excludes warranties arising out of this document and excludes all liability for loss and damages arising out of this document.

SUITE 550 - ±1,892 RSF

INTERIOR BATHROOM AND CORRIDOR RENOVATION PREVIOUSLY PERMITTED SEPARATELY

BUSINESS SUITEB - BUSINESS AREASAREA: 2356 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 100

2.40"

12 OCCPTS.

46"

BUSINESS SUITEB - BUSINESS AREASAREA: 2323 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 24

SUITE 400

BUSINESS SUITEB - BUSINESS AREASAREA: 677 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 7

SUITE 200

BUSINESS SUITEB - BUSINESS AREASAREA: 922 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 10

SUITE 300

01

02

03

0405

06

HATCHED AREA NOT IN SCOPE

SF1

EQ1 EQ1 EQ2 EQ2

STORAGE004

JAN.003

MENS002

WOMENS005

SF1

SF1

SF1

SF1

SF1

SF1 SF1 SF1 SF1 SF1 SF1

8'-0

"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

10'-

0"4'

-0"

7'-9

1/2

"3'

-8"

3'-8

"4'

-0"

4'-8

"4'

-0"

3'-9

1/2

"9'

-5 1

/2"

14'-

10"

109'

-10

1/2"

52'-9" 29'-9 1/2" 14'-11"

01

01

01

01

01

01 01 01 01 01 01

CONF. ROOM303

SUITE 300301

STO.302

BUSINESS SUITEB - BUSINESS AREASAREA: 3304 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 34

SUITE 500BUSINESS SUITEB - BUSINESS AREASAREA: 2486 SFAREA PER OCCUPANT: 100 SFOCCUPANT LOAD: 25

SUITE 600

3'-8" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 13'-4" 4'-0" 4'-8" 4'-0" 69'-0"

SUITE 400401

SUITE 500501

SUITE 600601

SUITE 200201

2.40"

12 OCCPTS.

68"

2.40"

12 OCCPTS.

68"

2.40

"

12 O

CCPT

S.

68"

CORRIDOR001

CORRIDOR001

63'-

10 1

/2"

43'-

10 1

/4"

52'-7 1/4" 8'-0" 18'-9 1/4"

21'-1" 10'-8"

CORE

1. ALL DIMENSIONS ARE TO FACE OF FRAMING, CENTER OF OPENINGS IN FRAMED WALLS, EDGE OF MASONRY OPENINGS, EDGE OF SLAB, AND COLUMN LINES UNLESS NOTED OTHERWISE.

2. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES GREATER THAN 2" PRIOR TO FRAMING WALLS.

3. ALL EXTERIOR FRAMING WITHIN 18" OF THE GROUND OR THAT COMES IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED.

4. DOOR AND WINDOW OPENINGS SHOULD ALLOW FOR A MINIMUM OF 4" CLEARANCE OF THE JAMBS TO ACCOMODATE SELECTED INTERIOR TRIM, UNLESS OTHERWISE NOTED.

2.00"

10 OCCPTS.

36"

# OF OCCUPANTS

PROVIDED WIDTH

EGRESS ARROW

REQUIRED WIDTH (PER IBC 1005.3.2)

EXIT SIGN

FIRE EXTINGUISHER CABINET

Project Number

Issued for Review

Issued for Permit

Issued for Construction

WWW.THEMIDDLETONGROUP.NET

Revisions

11/2

6/20

19 8

:32:

45 P

MA101

FIRST FLOORPLAN

18034

1350

Ash

ley R

iver R

oad

Jeff R

eed

12.4.2018

PERMIT SET

1350

Ash

ley R

iver R

oad,

Char

leston

SC,

2940

7

1/8" = 1'-0"A101

1 FLOOR PLAN

TRUE NORTHN

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEY NOTES01 NEW STOREFRONT SYSTEM IN PUNCHED OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR 501T/501UT

FRAMING IN DARK BRONZE KYNAR FINISH.

02 NEW STOREFRONT SYSTEM INFILL AT EXISTING OPENINGS. KAWNEER THERMALLY BROKEN OR EQUAL IR501T/501UT FRAMING IN DARK BRONZE KYNAR FINISH. VERIFY DIMENSIONS OF EXISTING OPENINGS IN FIELD.

03 EXISTING CONCRETE SLAB SLOPES TO GRADE. POUR SELF-LEVELING CONCRETE TO LEVEL AND PREPARE SLABFOR FINISH SELECTION.

04 REPOUR SECTION OF SIDEWALK TO SLOPE TO GRADE FROM STOREFRONT 1:20 SLOPE MAX.

05 NEW LANDSCAPING IN EXISTING PLANT BEDS, REFER TO L200.06 FREESTANDING SIGNAGE TOWER, SEE A301. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND

FRAMING DETAILS.

Name Occupancy Type AreaArea PerOccupant Occupant Load

CORE BUSINESS AREA 2043 SF 100 SF 21

SUITE 100 BUSINESS AREA 2356 SF 100 SF 24

SUITE 200 BUSINESS AREA 677 SF 100 SF 7

SUITE 300 BUSINESS AREA 922 SF 100 SF 10

SUITE 400 BUSINESS AREA 2323 SF 100 SF 24

SUITE 500 BUSINESS AREA 3304 SF 100 SF 34

SUITE 600 BUSINESS AREA 2498 SF 100 SF 25145

OCCUPANT LOAD

LEGEND

DESCRIPTION RENOVATION OF EXISTING SINGLE STORY OFFICE BUILDING (ENCLOSE EXISTING ENTRY, PROVIDENEW OPENINGS, REPLACE EXISTING FENCE, PROVIDE NEW LANSCAPING)

OCCUPANCYCLASSIFICATION

B - BUSINESS

SPRINKLER SYSTEM NOT SPRINKLEREDBUILDING AREA 14,123 SFNUMBER OF STORIES 1 STORYCONSTRUCTION TYPE III-BSEISMIC DESIGNCATEGORY

D

ZONING LB - LIMITED BUSINESSFLOOD ZONE XFIRE ALARM NONE

* THIS PROJECT HAS BEEN DETERMINED TO NOT BE A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE PER THE DEFINITION PROVIDED IN SECTION 44 CFR 59.1 OF NFIP REGULATIONS OR 2015 IBC.

GENERAL INFORMATION

No. Description Date

Bridge Commercial makes no guarantees, representations or warranties of any kind, expressed or implied, including warranties of content, accuracy and reliability. Any interested party should do their own research as to the accuracy of the information. Bridge Commercial excludes warranties arising out of this document and excludes all liability for loss and damages arising out of this document.

BRIDGE COMMERCIAL25 Calhoun Street, Suite 220Charleston, SC 29401+1 843 535 8600www.bridge-commercial.com

1 3 5 0 A S H L E Y R I V E R R O A DW E S T A S H L E Y, S C 2 9 4 0 7

OFFICE SPACE FOR LEASE

WWW.BRIDGE-COMMERCIAL.COM

MARK MATTISON, II CCIM, SIOR+1 843 437 [email protected]

WILL CROWELL+1 504 975 [email protected]

COLBY FARMER+1 978 998 [email protected]