1394_tct
TRANSCRIPT
-
8/13/2019 1394_TCT
1/2pag.128 - Product range 2010
* Units Series
Unit type
TCT-H horizontalunit
TCT-V verticalunit
Configuration
2R with 2-row coil
4R with 4-row coil
6R with 6-row coil
4-2R 4 pipes systems with 4+2-row
coil
6-2R 4 pipes systems with 6+2-row
coil
* Unit specifications
Large capacity fan coil, complying with
Machine Directive 89/392 EEC and
amendments 91/368 EEC, 93/44 EEC,
93/68 EEC, Low-Voltage Directives 72/23
EEC and Electromagnetic Compatibility Di-
rectives EMC 89/36 EEC.
Fan coil unit terminal for the treatment of
room air in the summer season (coil supplied
with cold water) and in winter (coil supplied
with hot water).
These units are suitable for indoor installa-
tion, very compact and amply configurable
to meet the requirements of highly qualified
designers.
The careful design of the main components,refined styling and the versatility of the pro-
duct make it suitable for any type of installa-
tion in commercial or industrial context.
Installation therefore only requires the electri-
cal and hydraulic connections.
Construction characteristics of versions
SUPPORT STRUCTURE: the frame of
the units is in UNI9006/1 Anticorodal 63
extruded aluminium alloy profiles, con-
nected with three-way joints in preloaded
nylon and sandwich closure panels, with
exposed side in white-grey pre-painted
steel and internal side in galvanised steel
sheet; unit thermal insulation/soundpro-
ofing is obtained through the injection of
polyurethane of density not less than 45
kg/m3.
AIR FILTER: removable sideways, it can
be regenerated simply by washing, and is
G3 efficiency class.
HEAT EXCHANGE COIL: made with
copper pipes arranged in staggered rows
and with corrugated aluminium finning,
locked by mechanical expansion of the pi-
pes. Complete with water inlet/outlet ma-
nifolds. The coil holding section provided
for on the TCT units is arranged to house
heating and/or cooling coils: the section
is designed to hold two coils in horizontal
and vertical models. The hot water coils
are 2-row or 4-row whereas for cooling
they can be 4-row or 6-row with chilled
water. The standard executions provide
for oblique fitting of the cooling coil in ver-
tical models and horizontal fitting of the
heating coil, and vertical fitting of both
coils in horizontal models.CONDENSATE TRAY: in stainless steel
sheet, complete with section for connec-
tion to the discharge line.
FAN MOTOR: ventilating section desig-
ned to limit fan noise as much as possible.
The motor-fan assembly is isolated from
the structure by means of suitable shock-
absorbers on the base and is complete
with neoprene vibration-mounting joint.
The centrifugal fans installed are dual-
intake with forward blades, statically and
dynamically balanced. Coupled-type fansare installed for sizes 100, 130 and 175.
Motor-fan coupling is by means of varia-
ble-pitch pulleys and V belts for all sizes.
Careful selection has enabled high effi-
ciencies to be obtained. The electric mo-
tors are 4-pole, externally ventilated and
class F isolated with IP55 protection ra-
ting, fixed on special guides enabling belt
tension adjustment. The use of variable-
pitch drive pulleys enables the number of
revolutions and therefore the pressure to
be adjusted to system requirements.
* Main accessories/Options
Inlet grill
Air inlet damper
Inlet plenum for vertical execution
Plenum with 1 damper
Plenum with 2 dampers
Outlet plenum
> TCT LARGE CAPACITY FAN COIL
-
8/13/2019 1394_TCT
2/2Product range 2010 - pag.129
Model 30 50 70 100 130 180
A mm 1180 1420 1660 1780 1940 2300
B mm 770 770 770 920 1100 1100
C/H mm 1290 1290 1290 1290 1290 1290
C/V mm 1540 1540 1540 1830 2010 2090
D1 mm 418 505 625 222 383 392
D2 mm 418 505 625 428 427 568
E mm 344 410 410 1130 1130 1340
F mm 304 354 354 354 354 417
G/H mm 360 390 390 390 390 410
G/V mm 150 150 150 105 105 105
I mm 700 700 700 850 1030 1030
L mm 1110 1350 1590 1710 1870 2230
UNIT TCT/H - TCT/V 30 50 70 100 130 180
Air flow (MIN MAX) 2300-3800 3900-6700 6300-8100 8200-11000 11000-15000 15000-20000 m3/h
Air flow rate nominal 3000 5300 7200 9600 13000 17500 m3/h
Total static pressure () 150-370 180-350 250-340 250-375 260-350 250-400 Pa
Sound pressure level(*) 58 73 70 68 71 69 dB(A)
Horizontal unit weight TCT-H 197 240 260 360 380 580 Kg
Vertical unit weight TCT-V 220 268 290 380 410 550 Kg
FanPower input 0,75 1,5 2,2 2,2 4 5,5 kW
N Fans / Poles 1/4 1/4 1/4 1/4 1/4 1/4 n
Power supply 400 / 3 / 50 V/ph/Hz
TCT 2R 30 53 72 95 130 175
Heating Capacity (*) 35,2 53 69,9 95,8 130 178 kW
Water flow rate 3,09 4,66 6,13 8,42 11,3 15,6 m3/h
Water pressure drop 9 4 8 10 12 23 kPa
Air pressure drop 18 32 38 35 35 39 Pa
Water connection 11/2 11/2 11/2 11/2 11/2 11/2 Gas
TCT 4R 30 50 70 100 130 180
Heating
Heating Capacity (*) 52,7 84,8 112 153 206 283 kW
Water flow rate 4,63 7,44 9,91 13,4 18,1 24,8 m3/h
Water pressure drop 15 15 27 33 41 45 kPa
Air pressure drop 32 52 57 51 53 58 Pa
Cooling
Cooling capacity total/sens (**) 31,2 / 17,8 46,5 / 27 62,7 / 36,4 86,9 / 50,5 117 / 68,1 161 / 91,8 kW
Water flow rate 5,2 7,8 10,5 14,5 19,6 26,9 m3/h
Water pressure drop 24 20 35 40 45 80 kPa
Air pressure drop 51 75 90 82 85 86 Pa
Water connection 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 Gas
TCT 6R 30 50 70 100 130 180
Cooling capacity total/sens (**) 36,2 / 19,9 60,7 / 34 78,3 / 43,9 108 / 60,6 146 / 81,8 200 / 110 kW
Water flow rate 6 10,1 13,1 18,1 24,4 33,5 m3/h
Water pressure drop 15 42 27 35 44 71 kPaAir pressure drop 60 90 95 95 96 90 Pa
Water connection 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 2 Gas
Dimensions
() Inlet air 0 C, water IN/OUT 70/60 C. max speed air fow.
() Inlet air 32 C, RH 50%. water IN/OUT 7/12 C. max speed air fow.
(*) Referred to the fan: deduct the pressure drop of the
selected components in order to get the external static pressure.
(**) Sound pressure level: data referred to 1,5 metres from inlet in free field. Theactual operation noise level generally differs from the values shown in the table,depending on operating conditions, reflected noise and surrounding noise.
> TCT LARGE CAPACITY FAN COIL