1401 east broad street richmond, virginia 23219 …...design (scan01.tif, enclosed for reference)...

6
1200 New Jersey Avenue, SE. Washington, DC 20590 March 27, 2008 In Reply Refer To: HSSD/B-151 Bryant L. Lowery, P.E. Special Design Engineer Location and Design Division Virginia Department of Transportation 1401 East Broad Street Richmond, Virginia 23219 Dear Mr. Lowery: This letter is in response to your request for Federal Highway Administration (FHWA) acceptance of a roadside safety device for use on the National Highway System (NHS). Name of device: Permatile Precast Concrete Barrier 10 foot length Type of device: Portable concrete barrier Test Level: NCHRP Report 350 TL-3 Prior Testing conducted by: Texas Transportation Institute (TTI) Date of request: March 14, 2008 You requested that we find this device acceptable for use on the NHS under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.” Requirements Roadside safety devices should meet the guidelines contained in the NCHRP Report 350, "Recommended Procedures for the Safety Performance Evaluation of Highway Features". FHWA Memorandum “Action: Identifying Acceptable Highway Safety Features” of July 25, 1997, provides further guidance on crash testing requirements of longitudinal barriers. Description You requested formal acceptance of the Virginia Department of Transportation (VDOT) 10 foot F-shape Concrete Barrier with the pin and loop positive connection. A 20 foot version of this design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance Letter B-54 dated May 18, 1999. Permatile Concrete Products Company manufactured and supplied this barrier that was tested by TTI under NCHRP report 350 Test 3-11, Contract No. T99011 and Project No. 402041. The drawings “Scan02.tif” and “Scan03.tif” include the details of the 10' version and are enclosed for reference. Archived - For Research and Historical Purposes Only

Upload: others

Post on 02-Jun-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

1200 New Jersey Avenue, SE. Washington, DC 20590

March 27, 2008

In Reply Refer To: HSSD/B-151

Bryant L. Lowery, P.E. Special Design Engineer Location and Design Division Virginia Department of Transportation 1401 East Broad Street Richmond, Virginia 23219 Dear Mr. Lowery: This letter is in response to your request for Federal Highway Administration (FHWA) acceptance of a roadside safety device for use on the National Highway System (NHS). Name of device: Permatile Precast Concrete Barrier 10 foot length Type of device: Portable concrete barrier Test Level: NCHRP Report 350 TL-3 Prior Testing conducted by: Texas Transportation Institute (TTI) Date of request: March 14, 2008 You requested that we find this device acceptable for use on the NHS under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

Requirements

Roadside safety devices should meet the guidelines contained in the NCHRP Report 350, "Recommended Procedures for the Safety Performance Evaluation of Highway Features". FHWA Memorandum “Action: Identifying Acceptable Highway Safety Features” of July 25, 1997, provides further guidance on crash testing requirements of longitudinal barriers.

Description

You requested formal acceptance of the Virginia Department of Transportation (VDOT) 10 foot F-shape Concrete Barrier with the pin and loop positive connection. A 20 foot version of this design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance Letter B-54 dated May 18, 1999. Permatile Concrete Products Company manufactured and supplied this barrier that was tested by TTI under NCHRP report 350 Test 3-11, Contract No. T99011 and Project No. 402041. The drawings “Scan02.tif” and “Scan03.tif” include the details of the 10' version and are enclosed for reference.

Archived - For

Research and

Historical Purposes

Only

Page 2: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

2

Crash Testing

The 20-foot long version of the VDOT barrier was successfully crash tested as noted above. Through the observation of crash testing of numerous portable concrete barrier segments of varying lengths over the years FHWA has learned that the length of the barrier plays little, if any, role in the successful performance. As long as the steel reinforcing and the integrity of the end connections are maintained, the shorter barrier length will be acceptable for use.

Findings

The 10-foot long VDOT barrier described above and detailed in the enclosed drawings is acceptable for use on the NHS under the range of conditions that the 20-foot barrier was tested, when proposed by a State.

Please note the following standard provisions that apply to FHWA letters of acceptance:

• This acceptance is limited to the crashworthiness characteristics of the devices and does not cover their structural features, nor conformity with the Manual on Uniform Traffic Control Devices.

• Any changes that may adversely influence the crashworthiness of the device will require a new acceptance letter.

• Should the FHWA discover that the qualification testing was flawed, that in-service performance reveals unacceptable safety problems, or that the device being marketed is significantly different from the version that was crash tested, we reserve the right to modify or revoke our acceptance.

• You will be expected to supply potential users with sufficient information on design and installation requirements to ensure proper performance.

• We expect you will wish to have suppliers of this device certify that the hardware furnished has essentially the same chemistry, mechanical properties, and geometry as that submitted for acceptance, and that it will meet the crashworthiness requirements of the FHWA and the NCHRP Report 350.

• To prevent misunderstanding by others, this letter of acceptance is designated as number B-151 and shall not be reproduced except in full. This letter and the test documentation upon which it is based are public information. All such letters and documentation may be reviewed at our office upon request.

Archived - For

Research and

Historical Purposes

Only

Page 3: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

3• This acceptance letter shall not be construed as authorization or consent by the FHWA to

use, manufacture, or sell any patented device for which the applicant is not the patent holder. The acceptance letter is limited to the crashworthiness characteristics of the candidate device, and the FHWA is neither prepared nor required to become involved in issues concerning patent law. Patent issues, if any, are to be resolved by the applicant.

Sincerely yours, David A. Nicol, P.E. Director, Office of Safety Design Office of Safety

2 Enclosures

FHWA:HSSD:NArtimovich:dp:x61331:03/27/08 S:/Directory Folder/Artimovich/B151PermtileVirginia.doc cc: Reader-HSA, NArtimovich-HSSD

Archived - For

Research and

Historical Purposes

Only

Page 4: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

NOTE: ALL NOTES SHOWN ON MB-7D PC SHALL APPLY TO THISBARRIER SHAPE.

2'

A

---------~"

A'4 lIAR

PLAN VIEW

I"

2'-Oa'-0"

'4 lIAR

rr-T

-::e:=-e:'i:"''''''''''''''''''''''''5.'5.s'''''' =.. 't ==== ;:;:;;::=====..'"-= =.."" I 8"

:- - [~4-~~~:---==========f:===--===============~==~=1 1I u 10"R U '0 lIAR n

1

"-0"n u .

====~=~=======~=========!===-=====~=======~=~====

4"4" 2" Ii"

2"2" 3"

ELEVATION VIEW

-.PRECAST TRAFFIC BARRIER SERVICE CONCRETE

CONNECTOR

'0

SECTION A-A

2'-8"

ij;7"

J" Ii"

END VIEW

."7D PC

2" MINIMUM

-,

". - - - "\...l

CONCRETE PRODUCTS COMPANYP.o... 204t. 100 ~ AD8d.8IIIIaI, VAJJN. 242103

(27I)-.aaz FAX:(271)~20

Archived - For

Research and

Historical Purposes

Only

Page 5: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

'--""

NOTES:1. ALL CONCRETE - 27.50 I.Apa (4000 p.l) UIN. COUPRESSIVE STREN<mi AT 28 tV.YS. 7. CU~,!.,t~ ~ lOOP POSITIVECONNECJ10N HARDWAREStW.L CONFOR'" TO2. ALL STEEL REINFORCDAENTSHAI..LCONfORM TO AS1\f 1.615/.4 CRACE 420 (CRACE 60) ''''''''''' V.D.O.T. SPEClACA110NS. FOR f>OSI"NECOtINEcmoH DETNI.$ AND3. UINIUUUClEARCONCRETECOVEROYERALL STEELSI-WJ. 8E 60mm (2"). . P!lENSlONS SEE SPECIAlDESIONDRAWINONO. 1.-105 Ie STD. DWO.NO.4. REFLECTNE BARRIERDEUNEATORSIZE,COlOR,ANDSPACINCTO BE IN 8 1I:,..:;l~S (SHEET 1 01 4) or V.D.O.T. ROAD AND BRIDGESTANDAADs Ie SPECS.

ACCORDANCEWITHPREVNUNG D.O.T. SPECIACATIONS. . """""ER DESIGN AND IAANUFACTUREMEETS OR EXC£EDS REQUIREMENTSOf'5. REFlECTIVEBARRIERDEUNEATORSFURNISHEDAND INSTALLEDBY OTHERS. V.D.O.T. STD. owe. NO. MB-7D PC. (SPECIFICA11ONREfERENCE 105. 612)6. 200mm X 300mm BARRIERVERTICAL PANas UAY 8E ADOED TO TOP 8. UNIT WEIGHT: 6100mm UNIT - 4,318 kg "

BARRIERIS REQUIRED. (20'-0" uNIt - 8500 lb..)

BARRIERVER'IICN.PNfELS I' 6100mm' .10P00tW. IS REQUIR£I) In !mRRUP 111.\ _'10 IUR 1'1/.\ ./':'13 BAR (I". 3 STIRRUP

113 BAR'(#4)

119 BAR (16)

113S11RRUP (#4)

119 BAR (16)

"3 BAR (14)

600

64

785DRAINAGE SLOT

SECTION R1-R1- -Noscw1:-- PLAN VIEWNO SCALE

TOP CONNECTOR

RI

T 6100mm

113 STIRRUP(14)'M'. 3 PCS.

6S5

8to 810 450

--. 45

113 BAR (14)785

DfWW« StDT

~NOSCALEENDVIEW

NO 5CW.E NOTE: ALL I*£NSlOfG ME. If UIUAIETERS.

1IJ1.E: PRECAST TRAFFIC ~R SERVICE CO~V.D.O.T. STD. MB-7D PC (METRIC F-'STYLE)

DAm 8-1\-88PROOUCr;TRAme~P~1U ORDEftNO.

64

113 BAR (14)

--113 lIAR (#4) 76

. :2... , ,,CONCRETE PRQDIICTB COIIIIPANY

P.O. Box H. 100 8eIcon RoIIf'. BIIIkif. VAJIN. 242031.e00.882.Q32 FAX 1~(l-eGNI20

ORAWII 1M ROW I no NO: \OOT'/W.GWQER I am<ED tIY: CIR SQAL£:AS NOTEDCUSJOIoIER NO.

Archived - For

Research and

Historical Purposes

Only

Page 6: 1401 East Broad Street Richmond, Virginia 23219 …...design (Scan01.tif, enclosed for reference) was tested and accepted for use as a TL-3 NCHRP 350 temporary barrier in FHWA Acceptance

NOTES:1. All CONCRETE- 27.50 MpQ (4000 psi) MIN. COMPRESSIVE STRENGTHAT 28 DAYS 7. ALLPIN c!cLOOPPOSITIVECONNECTIONHARDWARE StW.L CONFORM TO2. ALLSTEELREINf'ORCEMENTSHAlLCONFORMTO ASTMA615M GRADE420 (GRADE 60) CURRENT V.D.O.T. SPECiFICATIONS.FOR POSIlVE CONNECTIONDETNLS AND3. MINIMUMClEAR CONCRETE COVER OIlER All STEEl SHALl. BE 50mm (2"). 'DIMENSIONS SEE sPECIAl. DESIGN DRAWINGNO. A-105 c!c STD. DWG. NO.4. REFLECTIVEBARRIERDEUNEATORSIZE. COLOR. AND SPACING TO BE IN MB-INS (SHEET 1 of 4) OF' V.D.O.T. Ro.\D AND BRIDGE STANDARDSa: SPECS.

ACCORDANCEWITH PREVNUNG D.O.T. SPEciFICATIONS. a. BARRIER DESIGNAND tAANUFACTUREMEETS OR EXCEEDS REQUIREMENTSOF5. REFLECTIVEBARRIERDEUNEATORSFURNISHEDANDINSTALlEDBY OJHERS. V.D.O.T.STD, DWG.NO. MB-7D pc. (SPECIFICATIONREFERENCE105. 512)6. 200mm X 300mm BARRIERVERTICALPANELSMAYBE ADOED TOTOP 9. UNITWEIGHT- 3050mmUNIT- 2,159 kg .

BARRIER1<S REQUIRED. (10'-0" UNIT - 4750 Ibl.)

I' 3050mm 'I113 BAR (14) .

113 STI~RUP(14) £119 BAR(18) ~13 STI~RUP(I~ 119 BAR(I6~ 113 STIRRUP(14)

eMRIER VERTICALPANElSOPT1OHAl. I<S REQUIRED

50MIN. PLAN VIEW

NO SCAlE

113 BAR(14)

119 BAR (16)

113 STIRRUP (14)

'19 BAR (18)

113 BAR (14)

600

84

785DRAINAGESLOT

SECTION R1-R1- - -NO-s&L£--TOP CONNECTOR

R1

3050mm113 STIRRUP (14)

TYP. 3 PCS. 113 BAR (14)

555

.

H ==~======~===F ;;;l'= ===~====--9F IF ----= -- -

ill II II I84 1

1

11 119 BAR (18) II II 84-

n II II

..L.- -'- 45

8tO

75

J

~J

110

U ~[lSIDE 100

125U131808

SIDE ELEVATIONNO SCAlE

'13 BAR('4)785

DRAINAGE SLOT

'13 BAR ('4) 75

END VIEWNO SCALE NOTE: AU. DIMENSIONS ARE IN MIWMETERS.

1ITl£: PRECAST TRAFFIC BARRIER SERVICE CONCRETE- (01V.D.O.T. STD. MB-7D PC (METRIC F-STYLE)

DA1£: 8-11-118

PRODUCT: TRAFFIC BARRIERCONfRACTOR:

PER~TIlE ORDER NO.

64