Read and save these
IMPORTANT:Installer: Leave InstallationInstructions with the homeowner,Homeowner: Keep InstallationInstructions for future reference,Save installation Instructions for localelectrical inspector's use,
Write down the model and serial numbersbefore installing cooktop,
Both numbers are on the model/serialrating plate, located on the underside ofthe cooktop burner box,
Model #
Serial # Part No, 3191827 Rev, B
Befere you start°°°Your safety and the safety ofothers are very important.
We have provided many importantsafety messages in this manual andon your appliance. Always read andobey all safety messages.
This is the safety alertsymbol.This symbol alerts you to
potential hazards that can kill or hurtyou and others.
All safety messages will follow thesafety alert symbol and either theword "DANGER" or "WARNING".These words mean:
You can be killed or seriouslyinjured if you don't immediatelyfollow instructions.
You can be killed or seriouslyinjured if you don't followinstructions.
All safety messages will tell youwhat the potential hazard is, tell youhow to reduce the chance of injury,and tell you what can happen if theinstructions are not followed.
Important: Observe aH governingcodes and ordinances.
WARNING: _f theinformation in this manua_is not followed exactly, afire or expRosion may resultcausing property damage,persona_ injury or death.
m Do not store or use
gasoline or otherflammable vapors and_iquids in the vicinity ofthis or any otherappliance.WHAT TO DO _FYOUSMELL GAS
o Do not try to _ight anyappliance.
o Do not touch anyeRectrica[ switch.
o Do not use any phone inyour building.
o _mmediatemy cam[yourgas supplier from aneighbor's phone. Followthe gas supp_[er'sinstructions.
o _f you cannot reach yourgas supplier, call the firedepartment.
_nstaHation and service
must be performed by aquamified installer, serviceagency or the gassupplier.
Note: This cooktop is manufactured foruse with Natural gas. To convert toLR/Propane gas, see instructions in theGas Conversion Kit provided in literaturepackage.
Proper gas suppJy connection must beavailable. See "Gas supply requirements,"Page 4.
Proper installation is your responsibility.Have a qualified technician install thiscooktop.Make sure you have everythingnecessary for correct installation. It is theresponsibility of the installer to complywith the installation clearances specifiedon the model/serial rating plate. Themodel/serial rating plate can be found onthe underside of the cooktop burner box.
Check location where cooktop will beinstalled. The location should be awayfrom strong draft areas, such as windows,doors and strong heating vents or fans.
Do not obstruct flow of combustion andventilation air.
All openings in the wall or floor where thecooktop is to be installed must be sealed.
When installing a cooktop under existingcabinets and the installation does not
meet the minimum cabinet clearances,
install a range hood above the cooktop toavoid burn hazards.
Electdcat ground is required. See"Electrical Requirements," Pages 4-5.
It is the customer's responsibility:
To contact a qualified electricalinstaJJer.To assure that emectrical installation is
adequate and in conformance withNationam EJectrical Code, ANSJ/NFPA70 -- latest edition*, or CanadianElectrical Code, C22.1 -1982 and C22.2No. 01982 (or Jatest edition)** and aHlocal codes and ordinances.
Copies of the standards listed may be obtainedfrom:
*National Fire Protection Association
One Batterymarch ParkQuincy, Massachusetts 02269
** CSA Bntemational6501 East Pmeasant Valley Rd.C_eveJand, OH 44131-8575
neededfer
pencil
Countertop opening dimensions thatare shown must be used. Givendimensions provide required clearances.Mobite home installation: Theinstallation of this cooktop must conformto the Manufactured Home Constructionand Safety Standards, Title 24 CFR, Part3280 (formerly the Federal Standard forMobile Home Construction and Safety;Title 24 HUD part 280); or when suchstandard is not applicable, the Standardfor Manufactured Home Installations(Manufactured Home Sites, Communitiesand Setups), ANSI A225.1 -- latestedition*, or with local codes.
in Canada, the installation of this cooktopmust conform with the current standardsCAN/CSA-Z240 -- latest edition**, or withlocal codes.
1" (2.5 sin} min,space betweenadjacent cooktops
Do eat seal
25" (63.5 crn) min,=deep caantertop Usrequired
,°Gas Hne apenUeg--Walh anywhere 5""(12.7 crn)below endersUdnofcouetertep, Cabinet floor:anywhere within 6" (15,2 cm)of rear wall is recommended,
*NOTE: 24" (61 cm) min. clearance if bottomof wood or metal cabinet is protected by not tessthan 1/4" (0.6 cm) flame retardant mittboardcovered with not tess than No. 28 MSG sheetsteel, 0.015" (0.04 cm) stainless steel, or 0.024"(0.06 cm) aluminum or 0.020"(0.05 cm) copper.
30" (76.2 cm) min. clearance between top ofcooking platform and bottom of an unprotectedwood or metal cabinet.
Groundedoutlet --Locatewithin24"(61crn)of right rearcareer
of cutout,
15"
(38.1 era)
38"
(76.2 era)
e o @ @
13-3/4" 19" 15" 2-1/8"(34.9crn) (48.3crn) (38.1crn) (5.4crn)
29"
(73.7crn}
35-1/4"(89.5crn)
42-3/4"(108.6crn)
19 _
(48.3cm)
19 _
(48.3crn)
19 _
(48.3cm)
30 '_
(78.2cm)
38 _
(91.4crn)
42"
(108.7cm)
2-1/8"(5.4crn)
2-1/8"(5.4crn)
2-1/8"(5.4crn)
2-7/8" 5-5/8"(7,3cm) (14,3cm)
5-5/8"(7:3 cm) (14,3crn)
(7:3cm) (14,3cm)
1iq/2",7:3cm) (2&4cm)
Base cabinet size:
CooktopSize Min. Base CabinetReqnired
15" (38.1 cm) 15" (38.1 crn)
30" (76.9 cm) 30" (78.2 crn)
36" (91.4 cm) 36" (91.4 crn)
43" (109.2 cm) 44" (111.8 crn)
If cabinet has a drawer, a 4" (10.2 cm)depth clearance from the countertop tothe top of the drawer (or other obstruction)in base cabinet is required. The drawerdepth may need to be shortened to avoidinterfering with the regulator.
G8$ $U
Explosion Hazard
Use a new AGA or CSA approvedgas supply line.Install a shut-off valve.
Securely tighten a_t gascon nections.
If connected to LP, have aqualified person make sure gaspressure does not exceed 14"water column.
Examples of a quamified personinclude licensed heatingpersonnel, authorized gascompany personnel_ andauthorized service personnelFailure to do so can result indeath, explosion, or fire.
Observe all governing codes andordinances,Important: Cooktop must be connectedto a regulated gas supply,
A RThis installation must conform with
local codes and ordinances. In theabsence of local codes, installations mustconform with American NationalStandard, National Fuel Gas Code ANSIZ22&1 --latest edition** or CANI --B149.1 or 2**.
BE Input ratings shown on the
model/serial rating plate are for elevationsup to 2,000 feet (610 m). For elevationsabove 2,000 feet (610 m), ratings arereduced at a rate of 4% for each 1,000feet (305 m) above sea level.
EThe cooktop is equipped for usewith NATURAL gas. It is design-certifiedby CSA International for NATURAL andLR gases with appropriate conversion.The model/serial rating plate, located onthe underside of the burner box, hasinformation on the type of gas that can beused. If this information does not agreewith the type of gas available, check withthe local gas supplier. See Page 2 for LRgas conversion instructions.
mProvide a gas supply line of 3/4"rigid pipe to the cooktop location. Asmaller size pipe on long runs may resultin insufficient gas supply. Pipe-jointcompounds, suitable for use with L.R gas,must be used. With LR gas, piping ortubing size can be 1/2" minimum. LR gassuppliers usually determine the size andmaterials used on the system.
E mIf local codes permit, a new AGA or
CSA design-certified, 4-5 foot (! .2-1.5 m)long, 1/2" or 3/4" I.D., flexible metalappliance connector is recommended forconnecting this cooktop to the gas supplyline. Do Not kink or damage the flexibleconnector when moving the cooktop. Thepressure regulator has 3/8" female pipethreads. You will need to determine thefittings required, depending on the size ofyour gas supply line, flexible metalconnector and shutoff valve.
shnt0ftvalve___"open" pnniti0n _
tnc00kt0p.\__/ _-_J gas supply
F lineEThe supply line shall be equipped
with an approved shutoff valve. This valveshould be located in the same room asthe cooktop and should be in a locationthat allows ease of opening and closing.Do Not block access to the shutoff valve.The valve is for turning on or shutting offgas to the appliance.
G.if rigid pipe __
is used as a gassupply line, a combination of pipe Illfittings must be used to obtain an in-lineconnection to the cooktop. All strainsmust be removed from the supply andfuel lines so cooktop will be level and inline.
mThe regulator must be checked ata minimum 1-inch (2.5 cm) water columnabove the set pressure. The inlet pressureto the regulator should be as follows foroperation and checking the regulatorsetting:
NATURAL GAS:Set pressure 4 inches (10.2 cm).Supply pressure 7-14 inches (17.8 cmto 35.5 cm) maximum.L.P. GAS:Minimum pressure 10 inches (28.4 cm).Supply pressure 14 inches (38.8 cm).
mLine pressure testing:Testing above 1t2 psi (3.8 kPa)(14 inches (38.6 cm)) W.C. (gauge)The cooktop and its individual shutoffvalve must be disconnected from the gassupply piping system during any pressuretesting of that system at test pressuresgreater than 1/2 psig (3.5kPa).
Testing below 1t2 psi (3.8 kPa)(14 inches (38.6 cm)) WoC.(gauge) orlowerThe cooktop must be isolated from thegas supply piping system by closing itsindividual manual shutoff valve during anypressure testing of the gas supply pipingsystem at test pressures equal to or lessthan 1/2 psig (3.5 kPa).
Electrical Shock Hazard
Plug into a grounded 3-prongoutlet.
Do not remove ground prong.
Do not use an adapter.Failure to follow theseinstructions can result in death,fire, or emectricamshock.
tf codes permit and a separate groundwire is used, it is recommended that aqualified electrician determine that theground path is adequate.
Check with a qualified electrician ifyou are not sure whether the cooktopis properly grounded.Do Not ground to a gas pipe.
A 120-volt, 60-Hz, AC-only, 15-ampere,fused electrical supply is required. Atime-delay fuse or circuit breaker isrecommended. It is recommended that aseparate circuit serving only thisappliance be provided.
Electronicignitionsystemsoperatewithinwidevoltagelimits,butpropergroundandpolarityarenecessary.Inadditiontocheckingthattheoutletprovides120=voltpowerandiscorrectlygrounded,theoutletmustbecheckedbyaqualifiedelectriciantoseeif it is wired with correctpolarity. A wiring diagram is provided inthe literature package.
Important: This range is equipped withan electronic ignition system that will notoperate if plugged into an outlet that isnot properly polarized.
This appliance, when installed, must beelectrically grounded in accordance withlocal codes or, in the absence of localcodes, with the current CSA standardC22.1. Canadian Electrical Code Part 1.
Now start,,,With cooktop in kitchen.
Numbers
correspond to steps. 6.
Recommended ground methodFor your personal safety, this cooktopmust be grounded. This cooktop isequipped with a 3-prong ground plug. Tominimize possible shock hazard, the cordmust be plugged into a mating 3-prongground-type outlet, grounded inaccordance with the National ElectricalCode ANSI/NFPA 70 latest edition* orCanadian Electrical Code (CSA)** -- andlocal codes and ordinances. If a matingoutlet is not available, it is the personalresponsibility and obligation of the _
customer to have a properly polarized _- ->-_
and grounded, 3=prong outlet installed by
a qualified electrician.
3=pr0ngpolarized __
gr0und=type outlet
m Remove pressure regulator,3=pr0ng hardware package, burner grates andgroundplug caps from shipping package.
puv_ersupply cerd
E Remove foam shipping blocks andtape from cooktop. Untape power supplycord.
Copies of the standards listed above may beobtained from:
Lift entire cooktop up from cutout whenrepositioning cooktop in countertopopening to prevent scratching countertop.
*National Fire Protection AssociationOne Batterymarch ParkQuincy, Massachusetts 02269
** CSA International8501 East Pmeasant Valley Rd.C_eveJand, OH 44131-8575
3E Insert cooktop into countertop
opening. Center the cooktop in the cutout.Check that front edge of cooktop isparallel to front edge of countertop. Checkthat all required clearances are met. Usea pencil to outline the rear of the cooktopon the countertop. Remove the cooktopfrom the cutout and place upside downon a protected surface.
strip
4E Glass Cooktops Only:
Remove foam strip from literaturepackage. Apply foam strip around bottomof cooktop flush with edge.
front of ¢ooktop
5m Remove two screws from left and
right bottom edges of burner box. Placebrackets on top of burner box. Positionbrackets as shown and hand=tighten onescrew into each bracket.
m Reinsert the cooktop intocountertop opening. Check that cooktopis parallel to front edge of countertop. Liftentire cooktop to make adjustments.
saaktap saantertap/
' Iclamping screw
iburner " bracketbox
E SCrewsRotate brackets away from burnerbox. Install second screw into eachbracket and tighten brackets to burnerbox. Insert the 2-1/2" (6.4 cm) clampingscrews into the brackets. Use ascrewdriver to tighten clamping screwsagainst the underside of countertop.Do not overtighten screws.
m Install the pressure regulator withthe arrow on the regulator pointing uptoward unit and in a position where youcan reach the access cap.
IMPORTANT: All connections must bewrench-tightened. Do Not makeconnections to the gas regulator too tight.Making the connection too tight maycrack the regulator and cause a gas leak.Do Not allow the regulator to turn on thepipe when tightening fittings.
adapter 3/8"
valve sampaund regulator
All connections must be wrench=tightened.
E Assemble flexible metal connector
from the gas supply pipe to the pressureregulator. You will need to determine thefittings required, depending on the size ofyour gas supply line, flexible metalconnector and shutoff valve.
pipe-joint compound madefor use with NATURAL and L.R gas. Ifflexible metal connector is used, becertain tubing is not kinked.
sbntaffvaleea__jnC)_"open" pasUfl
/ _ gas supplyHne
EOpen shutoff valve in the gassupply line. Wait a few minutes for gas tomove through the gas line.
m Leak testing of the applianceshall be conducted according to thefollowing instructions:
Use a brush and liquid detergent to testall gas connections for leaks. Bubblesaround connections will indicate a leak. Ifa leak appears, shut off gas valvecontrols and adjust connections. Thencheck connections again. NEVER TESTFOR GAS LEAKS WiTH A MATCH OROTHER FLAME. Clean all detergentsolution from cooktop.
3m Plug power supply cord into
grounded outlet.
Put burner caps on each burnerbase. Place burner grates over burnerbases and caps.
E_ectronic _gnition System minitial lightingCooktop burners use electronic igniters inplace of standing pilots. When thecooktop control knob is pushed in andturned to the "LITE" position, the systemcreates a spark to light the burner. Thissparking continues until the control knobis turned to the desired setting.
O
O0oo
"'9_/"7tH
1 5. Check operation of the cooktopburners. Push in and turn each controlknob to "LITE" position. The flame shouldlight within 4 seconds. Do Not leave theknob in the "LITE" position afterburner Hghtso
If burners do not light properly, turncontrol knob to the "OFF" position. Checkthat burner cap is in the proper position.Check that power supply cord is pluggedin and that circuit breaker or house fusehas not blown. Check that the shutoffvalve is in the "ON" position. Checkoperation again. If a burner does not lightat this point, contact your Whirlpool dealerfor assistance.
m Push in and turn each controlknob to the '%0" (or simmer) setting. The'%0" setting of each burner has beenfactory set to the lowest setting availableto provide reliable reignition of the burner.if it does not stay lit on the '%O" setting,check '%O"setting as follows:
a. Turn control to "LiTE" until burnerignites.
b. Quickly turn knob down to LOWESTPOSITION.
c. If burner goes out, readjust valve asfollows:
Remove the surface burner control knob.Insert a flat-blade screwdriver into thehollow valve stem and engage the slottedscrew. Flame size can be increased ordecreased by turning the screw. Adjustflame until you can quickly turn knob from"LITE" to LOWEST POSITION withoutextinguishing the flame. Flame should beas small as possible without going out.
If ceoktepnet operate:
_ Check that the circuit breaker is nottripped or the house fuse blown.
[_ Check that the power supply cord isplugged into the outlet.
[_ Check that gas valves are turned tothe "ON" position.
[_See Use and Care Guide fortroubleshooting list.
If you need
tf you have questions about operating,cteaning or maintaining your cooktop:
[_ Refer to Use and Care Guide.
[_ Call the Consumer AssistanceCenter. Check your Use and CareGuide for the number to call or callthe dealer from whom youpurchased this appliance. The dealeris listed in the Yellow Pages of yourphone directory under "Appliances --Household -- Major -- Service andRepair."
Maintain the quality built into yourcooktop by calling an authorizedservice company.To obtain the name and number of theauthorized service company:
[_ Contact the dealer from whom youpurchased your cooktop; or
[_] Look in the Yellow Pages of yourtelephone directory under"Appliances -- Household --Major -- Service and Repair;" or
[_ Call the Consumer AssistanceCenter. The number is listed in yourUse and Care Guide.
When you call, you will need:
[_The cooktop model number.
[_] The cooktop serial number.
Both numbers are listed on themodel/serial rating plate located on theunderside of cooktop burner box.
ing andmaintenanceIf removing the cooktop is necessary forcleaning or maintenance, shut off gassupply. Disconnect the gas and electricsupply. Remove the mounting brackets onthe right and left side of burner box. Afterdisconnecting the gas and electric supply,finish removing the unit for cleaning andservicing. Reinstall in reverse order andcheck gas connection for leaks.
THE POWER CORD ONTNIS APPLIANCE IS EQUIPPED
WITH ATHREE PRONGED (GROUNDING) PLUG WHICHMATES WITN STANDARD THREE PRONGED (GROUNDrNG)WALL RECEPTACLES
PLUG
NEUTRAL 5/15WIDE BLADE
120VAC 60 HzI PHASE
15 OR 20 AMP
ROUND BLADE
CONNECT
,250 TERMINALS
ELK _i
(NOT USED)
(NOT USED)
VALVESWITCHES
SWITCHES ON VALVES
ELECTRtC CIRCUtT
CLOSED WHEN KNOB IS
ROTATED 55 ° TO 95 °
COUNTER CLOCKWISE
FROM OFF
GRN OR GRNIY ii_GROUNDI
WHT
SPARKMODULE
[I
I
EC3 IL....... I
iGNITOR
ELECTRODES _ .........
YEL ORBRN
THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH ATNREE PRONGED (GROUNDING) PLUGWNmCNMATES WITH STANDARD THREE PRONGED (GROUNDING)WALL RECEPTACLES
PLUG
ROUND BLADE
120VAC 60 HzI PHASE
15 OR 20 AMP
CONNECT,250 TERMINALS
ELK
VALVE
SWITCHES
SWITCHES ON VALVES
ELECTRIC CIRCUIT
CLOSED WHEN KNOB IS
ROTATED 55 ° TO 95 °
COUNTER CLOCKWISE
FROM OFF
GRN OR GRN/Y I I GROUND
WNT
MODULE
I II I
I__ <_ YELORBRN
(41 PLACES
IGNITOR
ELECTRODES............1............
GROUNDROUND BLADE
Caution: Label aI_ wires prior to disconnection when servicing controls.Wiring errors can cause improper and dangerous operation.Verify proper operation after servicing.
THE POWER CORD ONTNIS APPLIANCE I$ EQUIPPED
WITH ATHREE PRONGED (GROUNDING) PLUG WHCNMATES WITH STANDARD THREE PRONGED (GROUNDrNG)WALL RECEPTACLES
PLUG
CONNECT.250 TERMINALS
BLK _
VALVE
SWITCHES
SWITCHES ON VALVES
ELECTRIC CIRCUIT
CLOSEDWHEN KNOB ISROTATED55° TO 95°COUNTER CLOCKWISEFROM OFF
NEUTRAL5/16WIDE BLADE
120VAC 60 HzI PHASE
15 OR 20 AMP
,GROUND
WHT
ELK
SPARKMODULE
[I
: [3[]
_E_
Eli]
Eli]B,.......
YEL ORBRN
(6) PLACES
±
iGNITORELECTRODES
Caution: Label aI_ wires prior to disconnection when servicing controM.Wiring errors can cause improper and dangerous operation.Verify proper operation after servicing.
Caution: Label aII wires prior to disconnection when servicing controls.WiNng errors can cause improper and dangerous operation.Verify proper operation after servicing.
GROUNDROUND BLADE
THE POWER CORD ON THIS APPUANCE _S EQUIPPED
W_TH A THREE PRONGED (GROUNDING) PLUG WHICHMATES WITH STANDARD THREE PRONGED (GROUNDING)WALL RECEPTACLES
BLK
PLUG
_ _.................NEUTRAL 5/!5
_/ WIDE BLADE
/\.L/
GRN OR GRN]Y
GRN OR GRN/Y
FROM OFF ELECTRODES
120VA¢ 60 HzI PHASE
15 OR 20 AMP
I,GROUND
If'GROUNDSPARK
±
Caution: Label aH wires prior to disconnection when servicing controls.Wiring errors can cause improper and dangerous operation.Verify proper operation after servicing.
Part No, 3191827 Rev, B@2000 Whirlpool Corporation Benton Harbor, Michigan 49022 Printed in U,S,A,