SUBMITTAL © 2017 Ingersoll Rand All Rights Reserved TAG: _________________________________ 15 SERIES Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA M4MCW1509A-SUB-1B Specifications MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity (Btu/h): Minimum Cooling Capacity (@95F) (Btu/h): Maximum Cooling Capacity (@95F) (Btu/h): Total Capacity (W) (High/Standard/Low): Rated Power Input (W) Nominal Input Current (A) SEER Air Flow Volume (CFM) (H/M/L) Dehumidifying Volume (pt./h) EER (@95F) Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) Fan Motor RLA(A) Evaporator Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (D) x coil width (W) (inch) Output of Swing Motor (W) Fuse (A) Sound Power Level dB (A)(SH/H/M/L) Sound PRESSURE Level dB (A)(SH/H/M/L) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Outdoor Unit Compressor Type Compressor Oil L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Throttling Method Working Temp Range (°F) Condenser Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (H) x coil width (W) (inch) Fan Motor Speed (rpm) Output of Fan Motor (W) Fan Motor RLA (A) Air Flow Volume of Outdoor Unit (CFM) Fan Diameter (inch) Defrosting Method Sound Power Level dB (A) Sound PRESSURE Level dB (A) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Refrigerant Charge (oz) MCA MOP Connection Pipe Gas additional charge(oz/ft) Outer Diameter Liquid Pipe (inch) Outer Diameter Gas Pipe (inch) Max Height Distance (ft) Max Length Distance (ft) 1 Sound PRESSURE Level @ 3.3 ft. dB(A) M4MCW1509A / M4TCS1509A 208 / 230 / 1 60Hz 9000 3100 9600 2800 / 2600 / 900 900 4.0 15.0 310 / 280 / 240 / 170 1.69 10.0 M4MCW1509A1N0A 1350 / 1200 / 1050 / 750 0.20 Aluminum Fin-Copper Tube 1/5 2 - 1/18 23 × 7/8 × 10 1/2 1.5 3.15 53 / 49 / 45 / 39 43 / 38 / 34 / 28 31 1/9 x 10 5/6 x 7 7/8 34 x 10 2/3 x 14 4/9 19.8 / 24.2 M4TCS1509A11NA Swing Rotary DAPHNE FVC50K (PVE Oil) 16.5 6.60 845 Capillary 0 - 115 Aluminum Fin-Copper Tube 2/7 1 - 1/18 28 × 3/4 × 20 820±20 30 0.37 942 15 3/4 Automatic Defrosting 62 52 30 5/9 x 21 1/4 x 12 3/5 33 1/2 x 14 2/7 x 23 3/7 66.2 / 71.7 24.7 9.0 15.0 0.2 1/4 3/8 65 100

Upload: others

Post on 31-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • SUBMITTAL

    © 2017 Ingersoll Rand All Rights Reserved

    TAG: _________________________________

    15 SERIES

    Single Zone Mini-SplitInverter System

    M4MCW1509A1N0AM4TCS1509A11NA

    M4MCW1509A-SUB-1B

    Specifications

    MODEL - Cooling Only

    RATED Volts/PHFrequency (Hz)Rated Cooling Capacity (Btu/h):Minimum Cooling Capacity (@95F) (Btu/h):Maximum Cooling Capacity (@95F) (Btu/h):Total Capacity (W) (High/Standard/Low):Rated Power Input (W)Nominal Input Current (A)SEER Air Flow Volume (CFM) (H/M/L)Dehumidifying Volume (pt./h)EER (@95F)

    Indoor UnitFan Motor Speed (r/min) (SH/H/M/L)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound Power Level dB (A)(SH/H/M/L)Sound PRESSURE Level dB (A)(SH/H/M/L) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

    Outdoor UnitCompressor TypeCompressor OilL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

    Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

    1 Sound PRESSURE Level @ 3.3 ft. dB(A)

    M4MCW1509A / M4TCS1509A

    208 / 230 / 1 60Hz900031009600

    2800 / 2600 / 9009004.015.0

    310 / 280 / 240 / 1701.6910.0

    M4MCW1509A1N0A1350 / 1200 / 1050 / 750

    0.20 Aluminum Fin-Copper Tube

    1/5 2 - 1/18

    23 × 7/8 × 10 1/2 1.53.15

    53 / 49 / 45 / 3943 / 38 / 34 / 28

    31 1/9 x 10 5/6 x 7 7/8 34 x 10 2/3 x 14 4/9

    19.8 / 24.2

    M4TCS1509A11NASwing Rotary

    DAPHNE FVC50K (PVE Oil)16.56.60845

    Capillary0 - 115

    Aluminum Fin-Copper Tube2/7

    1 - 1/18 28 × 3/4 × 20

    820±2030

    0.37942

    15 3/4Automatic Defrosting

    6252

    30 5/9 x 21 1/4 x 12 3/533 1/2 x 14 2/7 x 23 3/7

    66.2 / 71.724.79.015.0

    0.21/43/865100

  • Unit DimensionsW D

    H

    3 1/262 1/8 2 1/8

    6 5/8 18 3/16 6 5/16

    Φ2 3/16 Φ2 3/16

    MODEL W H D09K 31 1/8 10 5/6 7 7/812K 33 1/4 11 3/8 8 1/4

    09K

    Unit: inch

    9K

    30 9/16

    21 1

    /4

    12 3/5

    82

    11 1

    /4

    20

    10 1/8

  • Air Velocity Patterns for High WallMax Horizontal Distance

    Unit: ft. (m)Model Cooling Mode Heating Mode

    M4MCW1509A 13.1 (4) N/A

    Clearance Requirements

    valve cover

    Space to the wal l

    Space to the ceiling

    Space to the wall

    Space to the wall

    Air outlet side Space to the floor

    or moreor more

    6 in. or more 6 in. or more

    12 in. or more

    20 in. or more

    20 in

    . or m

    ore

    12 in

    . or m

    ore

    or mo

    re

    .ni97

    or more

    Space to the obstruction

    Air outlet side

    Space to the wall

    Air inlet side

    The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures

    6 in.

    66in.

    118 in.

    NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m).

  • Performance Data

    Cooling Capacity 9,000 (Bthu/h) M4MCW1509A1/M4TCS1509A

    Capacities in these performance tables reflect normal operation at the temperatures indicated. See specification tables above for certified values under prescribed test conditions.

    DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 4400 3550 4750 3750 5250 4250 5600 44005 ‐15 4900 3900 5100 4050 5800 4600 5950 4750

    14 ‐10 5600 4400 5950 4750 6800 5450 6950 560023 ‐5 6100 4900 6650 5250 7650 6100 8000 645032 0 6450 5100 6800 5450 7650 6100 8000 630041 5 6650 5250 6950 5600 8000 6300 8350 665050 10 6950 5450 7300 5800 8350 6650 8700 680059 15 7500 6100 8000 6450 8850 7150 9700 780068 20 8500 6950 9000 7500 9700 8000 10400 850077 25 8500 6950 9000 7300 9550 7800 10200 835086 30 8000 6650 8500 7150 9350 7650 10050 835095 35 7650 6300 8150 6800 8850 7500 9700 8150

    104 40 7150 6100 7650 6450 8700 7300 9350 7800113 45 6800 5800 7300 6300 8350 6950 9000 7650

    Outdoor 68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)Coil air 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

  • 06/17

    The manufacturer has a policy of continuous product and product data improvement and it reserves the right

    to change design and specifications without notice.

    Mechanical Specifications

    Mini-Split Outdoor Unit

    General

    This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for out-door application.

    Unit Casing

    The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.

    Refrigerant Controls

    Refrigeration system controls include condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard

    Compressor

    The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise.

    Condenser Coil

    The coil shall consist of aluminum finned coils brazed to copper tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing.

    Low Ambient Cooling

    Matched Ameristar ductless products, have cooling capabilities at outdoor ambi-ent temperatures as low as 0° F.

    Mini-Split Indoor High Wall

    General

    The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed.

    Unit Casing

    Casing shall be provided with knockouts on the right, and left of the unit to facilitate pip-ing and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electri-cal terminal strip.

    Discharge Airflow and Distribution System

    Unit shall have auto swing, dual horizon-tal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle.

    Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow.

    Controls

    Units shall have the capability to be con-trolled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option.

    Remote Controller

    The unit shall have a wireless infrared re-mote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance.

    The wireless controller is included with all units.

    Healthy Filters

    The unit shall have an active carbon and catechin filter with the unit.The filters need to be cleaned at least once a year.

  • SUBMITTAL

    © 2017 Ingersoll Rand All Rights Reserved

    TAG: _________________________________

    15 SERIES

    Single Zone Mini-SplitInverter System

    M4MCW1512A1N0AM4TCS1512A11NA

    M4MCW1512A-SUB-1B

    Specifications

    MODEL - Cooling Only

    RATED Volts/PHFrequency (Hz)Rated Cooling Capacity (Btu/h):Minimum Cooling Capacity (@95F) (Btu/h):Maximum Cooling Capacity (@95F) (Btu/h):Total Capacity (W) (High/Standard/Low):Rated Power Input (W)Nominal Input Current (A)SEER Air Flow Volume (CFM) (H/M/L)Dehumidifying Volume (pt./h)EER (@95F)

    Indoor UnitFan Motor Speed (r/min) (SH/H/M/L)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound Power Level dB (A)(SH/H/M/L)Sound PRESSURE Level dB (A)(SH/H/M/L) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

    Outdoor UnitCompressor TypeCompressor OilL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

    Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

    1 Sound PRESSURE Level @ 3.3 ft. dB(A)

    M4MCW1512A / M4TCS1512A

    208 / 230 / 1 60Hz12000370012500

    3600 / 3500 / 110013005.815.0

    390 / 310 / 240 / 1902.969.25

    M4MCW1512A1N0A1350 / 1200 / 1000 / 800

    0.31 Aluminum Fin-Copper Tube

    1/5 2 - 1/18

    25 × 7/8 × 12 1/16 1.53.15

    55 / 49 / 45 / 3945 / 39 / 35 / 29

    33 1/4 x 11 3/8 x 8 2/936 1/4 x 11 x 15

    23.1 / 28.7

    M4TCS1512A11NASwing Rotary

    DAPHNE FVC50K (PVE Oil)16.56.60845

    Capillary0 - 115

    Aluminum Fin-Copper Tube 2/7

    2 - 1/18 28 × 1 1/2 × 20

    820±2030

    0.37942

    15 3/4Automatic Defrosting

    6353

    30 5/9 x 21 1/4 x 12 3/533 1/2 x 14 2/7 x 23 3/7

    70.6 / 76.130.09.015.0

    0.21/43/865100

  • Unit Dimensions

    W D

    H

    Φ2 3/16 Φ2 3/16

    4 11/16 21 5/16 7 1/4

    3 5/165

    1 3/8 1 3/8

    MODEL W H D09K 31 1/8 10 5/6 7 7/812K 33 1/4 11 3/8 8 1/4

    12K

    Unit: inch

    12K

    30 9/16

    21 1

    /4

    12 3/5

    82

    11 1

    /4

    20

    10 1/8

  • Air Velocity Patterns for High WallMax Horizontal Distance

    Unit: ft. (m)Model Cooling Mode Heating Mode

    M4MCW1512A 29.5 (9) N/A

    Clearance Requirements

    valve cover

    Space to the wal l

    Space to the ceiling

    Space to the wall

    Space to the wall

    Air outlet side Space to the floor

    or moreor more

    6 in. or more 6 in. or more

    12 in. or more

    20 in. or more

    20 in

    . or m

    ore

    12 in

    . or m

    ore

    or mo

    re

    .ni97

    or more

    Space to the obstruction

    Air outlet side

    Space to the wall

    Air inlet side

    The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures

    6 in.

    66in.

    118 in.

    NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m).

  • Performance Data

    Cooling Capacity 12,000 (Bthu/h) M4MCW1512A1/M4TCS1512A

    Capacities in these performance tables reflect normal operation at the temperatures indicated. See specification tables above for certified values under prescribed test conditions.

    Cooling 12K

    DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 5100 4000 5350 4200 6650 5200 6550 51005 ‐15 6100 4800 6450 5050 7700 6000 7750 6100

    14 ‐10 7650 6000 8100 6350 9150 7150 9500 745023 ‐5 7850 6150 8300 6500 9500 7450 9900 775032 0 8400 6600 9000 7050 10300 8050 10750 840041 5 10200 8000 10900 8550 11950 9350 13050 1020050 10 11550 9050 12250 9600 13100 10300 14050 1105059 15 11400 8950 12150 9500 13000 10200 13900 1090068 20 11150 8700 11850 9300 12850 10100 13700 1075077 25 10850 8500 11550 9050 12650 9900 13550 1060086 30 10550 8300 11300 8850 12400 9700 13350 1045095 35 10250 8050 11000 8600 12050 9450 13150 10300

    104 40 9750 7650 10500 8200 11700 9200 12650 9900113 45 9250 7250 10000 7800 11200 8800 12150 9500

    82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

    Outdoor Coil air

    68F DB (20C) 73F DB (23C) 80F DB (27C)

  • 06/17

    The manufacturer has a policy of continuous product and product data improvement and it reserves the right

    to change design and specifications without notice.

    Mechanical Specifications

    Mini-Split Outdoor Unit

    General

    This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for out-door application.

    Unit Casing

    The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.

    Refrigerant Controls

    Refrigeration system controls include condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard

    Compressor

    The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise.

    Condenser Coil

    The coil shall consist of aluminum finned coils brazed to copper tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing.

    Low Ambient Cooling

    Matched Ameristar ductless products, have cooling capabilities at outdoor ambi-ent temperatures as low as 0° F.

    Mini-Split Indoor High Wall

    General

    The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed.

    Unit Casing

    Casing shall be provided with knockouts on the right, and left of the unit to facilitate pip-ing and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electri-cal terminal strip.

    Discharge Airflow and Distribution System

    Unit shall have auto swing, dual horizon-tal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle.

    Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow.

    Controls

    Units shall have the capability to be con-trolled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option.

    Remote Controller

    The unit shall have a wireless infrared re-mote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance.

    The wireless controller is included with all units.

    Healthy Filters

    The unit shall have an active carbon and catechin filter with the unit.The filters need to be cleaned at least once a year.

  • SUBMITTAL

    © 2017 Ingersoll Rand All Rights Reserved

    TAG: _________________________________

    15 SERIES

    Single Zone Mini-SplitInverter System

    M4MCW1518A1N0AM4TCS1518A11NA

    M4MCW1518A-SUB-1B

    Specifications

    MODEL - Cooling Only

    RATED Volts/PHFrequency (Hz)Rated Cooling Capacity (Btu/h):Minimum Cooling Capacity (@95F) (Btu/h):Maximum Cooling Capacity (@95F) (Btu/h):Total Capacity (W) (High/Standard/Low):Rated Power Input (W)Nominal Input Current (A)SEER Air Flow Volume (CFM) (H/M/L)Dehumidifying Volume (pt./h)EER (@95F)

    Indoor UnitFan Motor Speed (r/min) (SH/H/M/L)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound Power Level dB (A)(SH/H/M/L)Sound PRESSURE Level dB (A)(SH/H/M/L) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

    Outdoor UnitCompressor TypeCompressor OilL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

    Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

    1 Sound PRESSURE Level @ 3.3 ft. dB(A)

    M4MCW1518A / M4TCS1518A

    208 / 230 / 1 60Hz

    18000710020000

    5800 / 5200 / 210018008.015.0

    470 / 400 / 340 / 2803.89.0

    M4MCW1518A1N0A1350 / 1200 / 1050 / 900

    0.30 Aluminum Fin-Copper Tube

    2/7 2 - 1/18

    28 1/7 × 1 × 122.53.15

    56 / 52 / 49 / 4546 / 42 / 39 / 35

    38 1/5 x 11 4/5 x 8 5/641 x 15 x 12 3/5

    29.8 / 36.4

    M4TCS1518A11NARotary

    RB68EP (POE Oil)16.512.081440

    Capillary0 - 115

    Aluminum Fin-Copper Tube2/7

    1 - 1/1834 5/7 × 6/7 × 26

    80060

    0.521883

    20 1/2Automatic Defrosting

    6656

    37 3/5 x 27 5/9 x 15 3/540 1/2 x 18 x 29 1/2

    90.4 / 100.335.316.025.0

    0.21/41/265130

  • Unit DimensionsW D

    H

    24 77 3/16

    5 1/27 1/2

    1 1/2

    Φ2 3/16 Φ2 3/16

    Unit: inch

    18K

    Models W H D18K 38 1/4 11 13/16 8 7/824K 42 1/2 12 13/16 9 11/16

    Unit: inch

    3513 3/8

    27 9

    /16

    15 5/8 38

    14 5

    /16

    22

  • Air Velocity Patterns for High WallMax Horizontal Distance

    Unit: ft. (m)Model Cooling Mode Heating Mode

    4MYW1618 30.2 (9.2) N/A

    Clearance Requirements

    valve cover

    Space to the wal l

    Space to the ceiling

    Space to the wall

    Space to the wall

    Air outlet side Space to the floor

    or moreor more

    6 in. or more 6 in. or more

    12 in. or more

    20 in. or more

    20 in

    . or m

    ore

    12 in

    . or m

    ore

    or mo

    re

    .ni97

    or more

    Space to the obstruction

    Air outlet side

    Space to the wall

    Air inlet side

    The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures

    6 in.

    66in.

    118 in.

    NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m).

  • Performance Data

    Cooling Capacity 18,000 (Bthu/h) M4MCW1518A1/M4TCS1518A

    Capacities in these performance tables reflect normal operation at the temperatures indicated. See specification tables above for certified values under prescribed test conditions.

    Cooling 18K

    DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 9450 7400 9850 7700 11200 8750 11850 93005 ‐15 10300 8050 10850 8500 12250 9600 12650 9900

    14 ‐10 11950 9350 12600 9900 14250 11150 14650 1150023 ‐5 13100 10250 14000 10950 16050 12550 16500 1295032 0 13550 10650 14500 11400 16650 13050 17150 1345041 5 14100 11050 15050 11800 17250 13550 17800 1395050 10 14600 11450 15650 12250 17900 14050 18450 1445059 15 15850 12450 17000 13300 18600 14550 19150 1500068 20 18000 14100 19100 14950 20400 16000 21050 1650077 25 17750 13900 18900 14800 20250 15850 20850 1635086 30 16900 13250 18000 14100 19650 15400 20250 1585095 35 16000 12500 16300 12800 18750 14700 19300 15100

    104 40 15200 11900 15550 12200 17350 13600 17900 14000113 45 14450 11300 15000 11750 16150 12650 16600 13000

    82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

    Outdoor Coil air

    68F DB (20C) 73F DB (23C) 80F DB (27C)

  • 06/17

    The manufacturer has a policy of continuous product and product data improvement and it reserves the right

    to change design and specifications without notice.

    Mechanical Specifications

    Mini-Split Outdoor Unit

    General

    This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for out-door application.

    Unit Casing

    The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.

    Refrigerant Controls

    Refrigeration system controls include condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard

    Compressor

    The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise.

    Condenser Coil

    The coil shall consist of aluminum finned coils brazed to copper tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing.

    Low Ambient Cooling

    Matched Ameristar ductless products, have cooling capabilities at outdoor ambi-ent temperatures as low as 0° F.

    Mini-Split Indoor High Wall

    General

    The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed.

    Unit Casing

    Casing shall be provided with knockouts on the right, and left of the unit to facilitate pip-ing and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electri-cal terminal strip.

    Discharge Airflow and Distribution System

    Unit shall have auto swing, dual horizon-tal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle.

    Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow.

    Controls

    Units shall have the capability to be con-trolled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option.

    Remote Controller

    The unit shall have a wireless infrared re-mote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance.

    The wireless controller is available for all units.

    Healthy Filters

    The unit shall have an active carbon and catechin filter with the unit.The filters need to be cleaned at least once a year.

  • SUBMITTAL

    © 2017 Ingersoll Rand All Rights Reserved

    TAG: _________________________________

    15 SERIES

    Single Zone Mini-SplitInverter System

    M4MCW1524A1N0AM4TCS1524A11NA

    M4MCW1524A-SUB-1B

    Specifications

    MODEL - Cooling Only

    RATED Volts/PHFrequency (Hz)Rated Cooling Capacity (Btu/h):Minimum Cooling Capacity (@95F) (Btu/h):Maximum Cooling Capacity (@95F) (Btu/h):Total Capacity (W) (High/Standard/Low):Rated Power Input (W)Nominal Input Current (A)SEER Air Flow Volume (CFM) (H/M/L)Dehumidifying Volume (pt./h)EER (@95F)

    Indoor UnitFan Motor Speed (r/min) (SH/H/M/L)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound Power Level dB (A)(SH/H/M/L)Sound PRESSURE Level dB (A)(SH/H/M/L) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

    Outdoor UnitCompressor TypeCompressor OilL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x depth (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

    Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

    1 Sound PRESSURE Level @ 3.3 ft. dB(A)

    M4MCW1524A / M4TCS1524A

    208 / 230 / 160Hz22000860023200

    6600 / 6400 / 2500226010.015.0

    700 / 640 / 580 / 5205.39.75

    M4MCW1524A1N01250 / 1100 / 900 / 800

    0.32 Aluminum Fin-Copper Tube

    2/7 2 - 1/17

    33 1/4 × 1 × 13 1/2 2.53.15

    58 / 54 / 50 / 4648 / 44 / 40 / 36

    42 4/9 x 12 4/5 x 9 2/345 1/5 x 16 1/4 x 13 7/9

    37.5 / 45.2

    M4TCS1524A11NRotary

    RB68EP (POE Oil)25

    11.291440

    Capillary0 - 115

    Aluminum Fin-Copper Tube3/8

    2 - 1/1833 1/3 × 1 3/4 × 26

    800600.4

    1883 20 1/2

    Automatic Defrosting6959

    37 3/5 x 27 5/9 x 15 3/540 1/2 x 18 x 29 1/2

    103.6 / 113.656.4515.025.0

    0.21/45/865130

  • Unit DimensionsW D

    H

    3 1/86

    1 11/16

    8 1/8 27 7 5/16

    Φ2 3/4 Φ2 3/4

    Unit: inch

    24K

    Models W H D18K 38 1/4 11 13/16 8 7/824K 42 1/2 12 13/16 9 11/16

    Unit: inch

    3513 3/8

    27 9

    /16

    15 5/8 38

    14 5

    /16

    22

  • Air Velocity Patterns for High WallMax Horizontal Distance

    Unit: ft. (m)Model Cooling Mode Heating Mode

    M4MCW1524 31.2 (9.5) N/A

    Clearance Requirements

    valve cover

    Space to the wal l

    Space to the ceiling

    Space to the wall

    Space to the wall

    Air outlet side Space to the floor

    or moreor more

    6 in. or more 6 in. or more

    12 in. or more

    20 in. or more

    20 in

    . or m

    ore

    12 in

    . or m

    ore

    or mo

    re

    .ni97

    or more

    Space to the obstruction

    Air outlet side

    Space to the wall

    Air inlet side

    The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures

    6 in.

    66in.

    118 in.

    NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m).

  • Performance Data

    Cooling Capacity 24,000 (Bthu/h) M4MCW1524A1/M4TCS1524A

    Capacities in these performance tables reflect normal operation at the temperatures indicated. See specification tables above for certified values under prescribed test conditions.

    Cooling 24K

    DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 10850 8500 11350 8900 12850 10050 13100 102505 ‐15 12100 9500 12800 10000 14450 11300 14850 11650

    14 ‐10 14050 11000 14850 11650 16750 13150 17250 1350023 ‐5 15400 12050 16450 12900 18850 14800 19450 1525032 0 15950 12500 17100 13400 19600 15350 20150 1580041 5 16550 13000 17700 13900 20300 15900 20900 1640050 10 17200 13450 18400 14400 21050 16500 21700 1700059 15 18650 14650 19950 15650 21850 17150 22550 1765068 20 21150 16550 22450 17600 24000 18800 24750 1940077 25 20900 16400 22250 17400 23800 18650 24500 1920086 30 19850 15550 21200 16600 23150 18150 23800 1865095 35 18800 14750 19200 15050 22050 17250 22700 17800

    104 40 17900 14000 18300 14300 20450 16000 21050 16500113 45 16950 13300 17600 13800 18950 14850 19550 15300

    82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

    Outdoor Coil air

    68F DB (20C) 73F DB (23C) 80F DB (27C)

  • 06/17

    The manufacturer has a policy of continuous product and product data improvement and it reserves the right

    to change design and specifications without notice.

    Mechanical Specifications

    Mini-Split Outdoor Unit

    General

    This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for out-door application.

    Unit Casing

    The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.

    Refrigerant Controls

    Refrigeration system controls include condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard

    Compressor

    The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise.

    Condenser Coil

    The coil shall consist of aluminum finned coils brazed to copper tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing.

    Low Ambient Cooling

    Matched Ameristar ductless products, have cooling capabilities at outdoor ambi-ent temperatures as low as 0° F.

    Mini-Split Indoor High Wall

    General

    The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed.

    Unit Casing

    Casing shall be provided with knockouts on the right, and left of the unit to facilitate pip-ing and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electri-cal terminal strip.

    Discharge Airflow and Distribution System

    Unit shall have auto swing, dual horizon-tal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle.

    Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow.

    Controls

    Units shall have the capability to be con-trolled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option.

    Remote Controller

    The unit shall have a wireless infrared re-mote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance.

    The wireless controller is included with all units.

    Healthy Filters

    The unit shall have an active carbon and catechin filter with the unit.The filters need to be cleaned at least once a year.