15 Stout Street Rejuvenating
Wellingtons most iconic buildingJason Quinn, GSAP, COR Associates
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
2/10
15 Stout Street
Tenant
Ministry of Business,Innovation and EmploymentOwner
Argosy Property LimitedSize
19,319 m2NLA per NZGBC
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
3/10
Design-Build Team Set our goal & it became another requirement
Main Contractor:McKee-Fehl Constructors LtdArchitect:Warren and Mahoney Architects LtdMechanical:COR Associates Ltd / Aquaheat Industries LtdStructural:Aurecon Group NZ
Electrical: Pacific Consultants / Frank Millar & Co.Plumbing:Michael Stretton Ltd / Professional Plumbing Solutions LtdFire:Aquaheat Industries Ltd / Holmes FireGreen Star Accredited Professional:COR Associates LtdTenant Representative: The Building Intelligence Group
Owner:Argosy Property Management LtdIndependent Commissioning Agent / Building Tuning: ECOsystems LtdBMS:Aquaheat Industries Ltd / Building Automation Systems LtdMechanical Commissioning: MK Lawson LtdAcoustics:Marshall Day Acoustics
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
4/10
Heritage Building 1939
Good fundamentals: structure, faade, goodglazing ratioImproved fundamentals: form factor, removedskylights, insulated new faade, highperformance atrium glazing and new windows.Issues: bronze single pane windows, copper
gutters, space external for visitor bicycles
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
5/10
Green Star Rating Points
45-59'Best Practice'
60-74'New ZealandExcellence
75-100'WorldLeadership'
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
6/10
Innovation
(3 out of 5)
Seismic in-situtesting
Temperzone multi-
fan EC fan coil
Advancedtemperature
setback controls
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
7/10
Designed to reduce impact
Insulation and glazing selected for performance
Atrium double glazed spectrally selective glass decreasedcooling and increased heating
LV8 standard low-e double glazing with low conductivity thermalspacers
Heat recovery ventilation provides 22 kWh/m2
annuallyremaining heating requires only 30 kWh/m2
Intelligent lighting control throughout the building dimming, occupancy sensors linked to BMS
Building Tuning: optimum start, airflows, cooling Measured water use reduced by 64%, ~consumption 360
L/m2annually (9% showers used quite a bit)
Measured energy use reduced by 46%, ~170 NZ homes
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
8/10
Indoor Environmental Quality Designed for excellent air quality
Used low VOC emitting materials in ceiling tiles,timber, carpets, fabrics, paint and adhesives
Dedicated tenant utility area exhaust risers
Outside air rates 2.5x NZBC for NZGBC design loading
CO2 monitoring and control system
Designed for visual comfort
Good surface illuminance levels
External views of the harbour and sky through atrium Intelligent lighting auto dimming tuned to satisfy
occupants
-
7/23/2019 15 Stout St Green Room Presentation Jason Quinn
9/10
Lessons Learned
Wellington Auckland Green star is flexible -
both good & bad
Suppliers are getting
better: Steel & PVC Paperwork wasnt as
integrated as it couldvebeen - documentation
chasing was required NABERSNZ retrofitted
-