Contents

Overview��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3Contacts ....................................................................................................................................................................3

POE 12 VDC Strike (Fail Safe) ���������������������������������������������������������������������������������������������������������������������������������������������4

POE 12 VDC Strike (Fail Safe) - COE BA ����������������������������������������������������������������������������������������������������������������������������5

POE 24 VDC Mag Lock (Fail Safe) Local Sounder�������������������������������������������������������������������������������������������������������������6

POE 24 VDC Mag Lock (Fail Safe) with External Power ���������������������������������������������������������������������������������������������������7

POE 12 VDC Strike (Fail Secure) �����������������������������������������������������������������������������������������������������������������������������������������8

External Power 12 VDC (Fail Secure) Strike - UL Configuration ��������������������������������������������������������������������������������������9

POE 12 VDC Lock - Fire Relay�������������������������������������������������������������������������������������������������������������������������������������������10

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved. page 3 January 2011

Overview

This application note provides wiring details for connecting the EdgePlus to extraneous devices. The following diagrams are for example only, and are not intended as a recommendation by HID Global.

CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de-energized due to magnetic field collapse� It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling relay contacts� Go to support�hidglobal�com, see Solution 891 - How do I wire a High In-Rush Current locking device to VertX/Edge/Edge Solo?�

• Local Sounder Exit Alarm

• Wiegand or PIN Card Reader

• REX Egress I.R.

• Remote Egress Button

• Door Position Switch

• Electric Door Strike

• Customer Owned Burglar Alarm

• Altronix Power Supply

• Securitron Power Supply

• 24 VDC Locking Device

• 12 VDC Locking Device

• Fire Alarm System Relay

ContactsAmericasHID Global Corporation (California, USA)Email: [email protected] Main: (949) 598-1600 Support: 1-800-237-7769 Fax: (949) 598-1690 Europe, Middle East and AfricaHID Global Corporation, Ltd. (Haverhill, UK)Email: [email protected]: +44 (0) 1440 714 850 Support: +44 (0) 1440 711 822 Fax: +44 (0) 1440 714 840 Asia-PacificHID Global Corporation Asia Pacific Ltd. (Hong Kong)Email: [email protected] Main: (852) 3160 9800 Support: (852) 3160 9802Fax: (852) 3160 4809

Note: For optimal quality, print the following diagrams on A.3, or B (Ledger) size paper.

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

EdgePlusPoE 12 VDC Strike (Fail Safe)

Field Wiring

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

Door PositionSwitch

Electric Door Strike(Fail-safe)

POE Switch or Midspan Injector Powered

Local SounderExit Alarm(Optional)

REX Egress I.R.

page 4

POE 12 VDC Strike (Fail Safe)

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

EdgePlusPoE 12 VDC Strike (Fail Safe)

Customer Owned Equipment (COE) BAField Wiring

Customer Owned Burglar Alarm System

POE Switch or Midspan Injector Powered

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

Remote Egress Button(Optional)

Door PositionSwitch

Electric Door Strike(Fail-safe)

page 5

POE 12 VDC Strike (Fail Safe) - COE BA

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

POE Switch or Midspan Injector Powered

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

Remote Egress Button(Optional)

Door PositionSwitch

24 VDC Locking Device(Fail-safe)

Local SounderExit Alarm(Optional)

Altronix AL1024ULACMCB Power Supply

PoE 24 VDC Magnetic Lock (Fail Safe) Local Sounder Field Wiring

page 6

POE 24 VDC Mag Lock (Fail Safe) Local Sounder

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

REX (Request to Exit) Egress I.R.

Door PositionSwitch

24 VDC Locking Device(Fail-safe)

Altronix AL1024ULACMCB Power Supply

EdgePlusPoE 24 VDC Mag. Lock (Fail Safe) External Power

Field Wiring

POE Switch or Midspan Injector Powered

page 7

POE 24 VDC Mag Lock (Fail Safe) with External Power

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

POE Switch or Midspan Injector Powered

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

Door PositionSwitch

Electronic Door Strike(Fail-secure)

Edge PlusPoE 12 VDC Strike (Fail Secure)

Field Wiring

REX (Request to Exit) Egress I.R.

page 8

POE 12 VDC Strike (Fail Secure)

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved.

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

EdgePlusExternal Powered

12 VDC (Fail Secure) StrikeUL Configuration

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000.

Door PositionSwitch

12 VDC Locking Device(Fail-Secure)

External provided by UL listed power supply

Remote Egress Button (Optional)

Local Sounder Exit Alarm(Optional)

Securitron BPSM-12-6Power Supply

page 9

External Power 12 VDC (Fail Secure) Strike - UL Configuration

© 2008 - 2011 HID Global Corporation. All rights reserved.January 2011

Edge Connections - AN0108, B.0

© 2008 - 2011 HID Global Corporation. All rights reserved. page 10

RLY 1 PWR

RLY 2 PWRPoE PWR

Tamper

Wiegand or PIN Card ReaderOnly use reader for 82000 and 83000

Fire Alarm System Relay

POE Switch or Midspan Injector Powered

EdgePlusPoE 12 VDC Lock (Fire Relay)

Field Wiring

POE 12 VDC Lock - Fire Relay