Total system
Battery charging discharging Pv cellRESULTSTIMECharacyeristics
0-1s1) Solar energy with full irradiance2) Wind Turbine tends towards base speed of 12ms after 0.5 s3) Battery gives partial supply to load4) Load is 10 KW
1-2s1) Wind achieves 5.6 KW2) Battery stores 5 KW
2-3s1) Solar Energy Reduced by 15 2) Battery stores 3.5 KW
3-4s1) Wind speed decreases by 25 to 9ms2) Battery gives partial supply to load
4-5s1) Load is increased by 40 2) Battery is responsible to overcome 40 load demand
5-6sLoad demand comes to previous point
TABLE 7.2 Verbal Description Of Solar PanelPROPERTYDETAILS
Company NameZhejiang Trunsun Solar Co., Ltd.(China)
Size of cells156 mm 156 mm
Weight19 Kg
Operating Temperature40 to 80
ModuleTSP 215
No. of modules2
TABLE 7.3 Ratings Of Solar PanelPANEL MODELOPENCIRCUITVOLTAGE()MAXIMUMPOWERVOLTAGE()SHORTCIRCUITCURRENT()MAXIMUMPOWERCURRENT()
TSP 22036.60 V29.7 V7.52 A6.73 A
TSP 20536.60 V30.0 V7.75 A6.83 A
TSP 21036.60 V30.0 V7.75 A7.00 A
TSP 21536.90 V30.3 V8.01 A7.10 A
The values yielded for the solar panel are:Open circuit voltage = 36.9 MPPT voltage= 30.3 VShort Circuit Current = 8.01 AMPPT current = 7.10 ANo. of cells in a row = 11No. of cells in PV array 22 cellsOpen Circuit Voltage of PV array VMPPT voltage of PV array 666.6 V ~ 666 VPercentage of Error in accomplishing MPPT MPPT Voltage = Preferred DC Link voltage 640 VMaximum ower from single cell = = 30.3 7.10 Maximum Power from single row Maximum Power acquired from single module W Total Maximum Power acquired from two modules = ( 2 ) W
Maximum Irradiance = 1000Maximum Power at Maximum Irradiance WPercentage of irradiation came down after 2 s remainingAmount of Solar Power cut down W
The values yielded for the wind system are:N=Where, f The output frequency of PMSGP Number of poles = 4NSynchronous speed for that frequency N= = 1500 rpm (revolutions per minute)Conversion into radians per second rads1500 rpm 1500 157 radsNominal mechanical output power of wind turbine = 8500 WPower = Base Torque = = = 54.14 JActual Torque = Tm(p.u) Base TorqueBattery System:Maximum SOC required to be obtained after charging = 80 %Starting SOC = 60%Maximum Power Rating for Battery Storage = 5 KWLoadMaximum Load demand from 1-6 sec except 4-5 sec = 10 KWMaximum Load demand from 4-5 sec = 15 KWTime at which the Circuit Breaker closes switch to give current to load = [4 5] sec
TABLE 7.4 Ratings of Polycrystalline Solar Panel TSP 230
ModulePolycrystalline Solar Panel TSP 230
EncapsulationGlass/PVB/Cells/PVB/Glass
Size and Number of cells125mm125mm
Maximum power180w
Maximum power voltage(Vmp)36.00V
Maximum power current(Imp)5.00A
Open circuit voltage(Voc)43.20V
Short circuit current(Isc)5.80A
Model size(mm)1700*860*9mm
Weight38kgs
Operating Temperature40C to+85C
TABLE 7.5 Ratings of BIPV Double Glass Solar Panel TSBM 180
ModuleBIPV Double Glass Solar Panel TSBM 180
EncapsulationGlass/EVA/Cells/EVA/TPT
Size and Number of cells125mm125mm
Maximum power230Wp
Maximum power voltage(Vmp)30.00V
Maximum power current(Imp)7.67A
Open circuit voltage(Voc)36.00V
Short circuit current(Isc)8.59A
Model size(mm)163899150
Weight21.5Kg
Operating Temperature-40C to 85C
The working performance of different solar panel models is represented through simulation results. The difference in the output occurs due to the differed voltage and current ratings of the panel. The derived voltage voltage and current ratings depend on the physical conditions prevailing in its vicinity and on its physical characteristics.
91
Fig 7.1 Load Sharing Action Performed by the Hybrid Energy Energy in Polycrystalline Solar Panel TSP 215
Fig 7.2 Load Sharing Action Performed by the the Hybrid Energy Energy in BIPV Double Glass Solar Panel TSBM 180
Fig 7.3 Load Sharing Action Performed by the the Hybrid Energy Energy in Polycrystalline Solar Panel TSP 230
TABLE 7.6 Load Sharing Between Solar & Wind Systems Supported By BatteryTIME(sec)LOAD() WSOLAR() WWIND() WBATTERYPOWER() WBATTERYACTIONREMARKS
0 00.8 s0.08SupplyingG < L
0.03 0.8 s0.05
0560.5ChargingG > L
0.563.4ChargingG > L
0.20.02SupplyingG L
0.24.2SupplyingG < L
0.20.02SupplyingG L
SIMULATED GRAPHS: The load demand to fulfill is 10 KW throughout the time scale except at 4 to 5 sec when it increases to 14 KW. Solar energy drops its irradiance to 15 % from 2 sec. Wind turbine initially rotating at 5m/s excels to base speed 12m/s after 0.5 sec. Its rotating speed is decreased to 25 % of its base speed. All these conditions are clearly observed in the below graph.The Maximum Voltage is of PV Array is observed at around 640 V. the curve below explains that the varying irradiance is the deciding factor of the maximum voltage derived.TABLE 7.7 Major Landmarks of Proposed Hybrid System
TIMESOLAR ENERGYWINDENERGYBATTERYLOAD
0-1Speed Tends Towards Base Speed
1-2SignificantCharging
2-3Irradiance DropSpeed falls
3-4
4-5Mainstay Load SharingAdditional Load Attached
5-6
Fig 7.4 Phase Voltage observed at the PV array
Fig 7.6 The load current supplied to the load is sinusoidal in nature as depicted in the simulation
Fig 7.7 Three Phase Voltage Supplied To The Load By The Inverter
Fig 7.8 AC Line Voltage and Phase Voltage Given By The Inverter
TABLE 7.8 Inverter Output VoltageTIMEPHASE VOLTAGE
1 s230
2 s230
3 s230
4 s230
5 s230
6 s230