17. virtual connect stefan jönsson.ppt
TRANSCRIPT
![Page 1: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/1.jpg)
© 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice
Technology for better business outcomes
Virtual ConnectStefan Jönsson – Hewlett-PackardInfrastructure Solution Architect
![Page 2: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/2.jpg)
2
Why Virtual Connect is vital to you!Virtual Connect is foundational
• Foundation for:−HP’s (and your) future data center transformation
business and HP virtualization strategy — No VC means no AI
−Insight Dynamics — VSE, managing physical and logical servers (no VC and ID doesn’t work and you don’t sell it)
−HP BTO software
![Page 3: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/3.jpg)
HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class Blade System
and
HP NC532m Dual Port Flex-10 10GbE Multifunction BL-c Adapter
![Page 4: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/4.jpg)
4
Traditional blade servers need too many modules & mezz cards!
DualLOM
QuadNIC
8Interconnect Modules
Net 2 Net 3 Net 4Net 1
4Redundant networks
8NICs require
QuadNIC
DualNIC 2
Mezz cards
![Page 5: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/5.jpg)
Introducing the next Virtual Connect breakthroughVirtual Connect Flex-10 technology• 4X more I/O connections per server
− Dual-channel 10Gb Flex-10 NIC onboard delivers 8 FlexNICs on the motherboard
− 24 FlexNIC connections per server via expansion slots
− 100% hardware-level performance− User-adjustable bandwidth from 100Mb to 10Gb
for each FlexNIC
• Virtual Connect Flex-10 technology− Delivered in the Virtual Connect Flex-10 module− VC Flex-10 reduces cables and simplifies NIC
creation, allocation and management
• Save money at every turn− Lowest cost solution for 4 or more NICs− Lowest power consumption for 6 or more NIC – up
to 270w savings per enclosure
HP Virtual Connect Flex-10Ethernet module
![Page 6: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/6.jpg)
VC Flex-10 drops Mezz & Modules by 75%!
Dual Flex-10Controller
8 2Interconnect Modules
4Redundant networks
8NICs require
2 0Mezz cards
Net 2 Net 3 Net 4Net 1
![Page 7: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/7.jpg)
Expandable to 4x more NIC connections than any other server blade
NICconnections
Up toVirtualConnectFlex-10
VirtualConnectFlex-10
VirtualConnectFlex-10
Built-in LOM
Optional Mezz Card
Optional Mezz Card
Easy and cost effective to add more NICs to support more virtual servers ( )
![Page 8: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/8.jpg)
First ever to provide precise control over bandwidth per NIC connection
Fine-tune the speed of each network connection
So you can set and prioritize performance for each VM channel
In 100Mb increments
from 100Mb to 10Gb
( )
VirtualConnectFlex-10
VirtualConnectFlex-10
![Page 9: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/9.jpg)
HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class Blade System
Item Description
1 1x 10GBASE CX4 Ethernet or 1x SFP+ module (X1)
2 Part number and status indicators
3 5x SFP+ modules (X2-6) (1GbE or 10 GbE)
4 2x crosslinks (midplane) or 2X SFP+ module (X7-8)
5 Recessed module reset button
1 2 3 4 5
Midplane: 16x 10GBASE-KR Ethernet - connects to one (1Gb or 10Gb) NIC in each half-height blade bay
2x 10Gb Ethernet - Crosslink between adjacent Virtual Connect Ethernet modules
Management interfaces to Onboard Administrator
![Page 10: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/10.jpg)
HP NC532m• Supported per ProLiant c-Class
server, in mezzanine slots 1, 2, or 3 (full-height servers) or slots 1, 2 (half-height servers)
• Type I adapter fits all server mezzanine slots for maximum flexibility
• Supports HP exclusive Flex-10 technology
• IEEE 802.1p QoS 802.3x flow control, and 802.3ap 10GBase-KR
• 9K Jumbo frames• Dual 10Gb ports offer the most
bandwidth of any adapter card• Set any bandwidth from 100Mb
to 10Gb on up to four “Physical Function “ NICs per port
![Page 11: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/11.jpg)
10GbE c-Class Mezzanine Hardware Feature Summary
Model HP NC532m1 HP NC512m
10GbE protocol IEEE 10G-Base-KR IEEE 10G-Base-KX4
Network Controller Broadcom 57711 Netxen NX2031
Bus x8 PCI Express v2.0 (Gen2) x8 PCI Express 1.1
Ports (Mbps) 2 @ 1,000 or 10,000 2 @ 10,000,
Server Support All ProLiant c-Class with type I slots
Most ProLiant c-Class type II slots
Form Factor Type I card Type II card
Supported Interconnects
New 10 GbE KR Virtual Connect
Existing interconnects with 1Gb downlinks and 1GBE pass
thru
HP 10Gb Ethernet BL-c Switch
Maximum cards per server
3 per FH server 2 per HH server
1 per FH server, 1 per HH server
Supported Enclosures c3000 and c7000 c3000 and c7000
Server memory requirements
1GB minimum, up to server’s capacity
maximum
4GB minimum, 32GB max (Windows), 64GB max
(Linux)
![Page 12: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/12.jpg)
How Virtual Connect Flex-10 works
Each Flex10 Mezzanine has two 10Gb physical ports
Port 1
NIC
10Gb VC-EnetModule (Odd)
ServerBlade
Single lane of 10Gb/s Ethernet
for each Port
NIC NIC NIC
Port 2
NIC NIC NIC NIC
Flex10 LOM or Mezz Card
10Gb VC-EnetModule (Even)
Goes to separateinterconnect bays(Odd, Even)
![Page 13: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/13.jpg)
FlexNIC’s are hardware devices Configure network connectivity anytime
−For each NIC (PF), VC sets:• Bandwidth (0.1 to
10Gb/s)• Port type (NIC or iSCSI) • MAC address• vNet connection
10Gb VC-EnetModule (Odd)
ServerBlade
Port 1
NIC NIC NIC NIC
Port 2
NIC NIC NIC NIC
Flex10 LOM or Mezz Card
![Page 14: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/14.jpg)
Demo
14April 12, 2023
![Page 15: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/15.jpg)
One network configuration consolidates your network regardless of the number NICs/server
2 NICs
4 NICs
6 NICs
8 NICs
Simplify
the number of network configurations
![Page 16: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/16.jpg)
HP Virtual Connect family positioning
Virtual Connect Flex-10
Virtual Connect 1/10Gb-F
Virtual Connect 1/10Gb
Best for Virtual Servers and network consolidation
Mainstream high performance BladeSystem interconnect
Lowest cost, entry level Virtual Connect module
Network Connections • 16 x 10Gb downlinks midplane
• 2 x 10Gb cross connect• 1 x 10Gb copper uplinks CX-4• 8 x 10Gb SR, LR, or LRM fiber
uplinks SFP+• 1 management USB port• 1 internal interface to c-Class
Onboard Administrator Module
• 16 x 1Gb downlinks midplane• 1 x 10Gb cross connect• 1 x 10Gb copper uplinks CX-4• 2 x 10Gb SR or LR fiber uplinks
XFP• 2 x 1Gb SX or RJ-45 fiber uplinks
SFP• 4 x 1Gb 1000/100/10Gb
copper uplinks RJ-45• 1 management USB port• 1 internal interface to c-Class
Onboard Administrator Module
• 16 x 1Gb downlinks midplane
• 1 x 10Gb cross connect• 2 x 10Gb copper uplinks CX-
4• 8 x 1Gb 1000/100/10Gb
copper uplinks RJ-45 • 1 management USB port• 1 internal interface to c-
Class Onboard Administrator Module
Performance
• Line rate, full-duplex 240Gbps bridging fabric
• Less than 1s latency
• Line rate, full-duplex 62 Gbp/s bridging fabric
• Less than 4s latency
• Line rate, full-duplex 54 Gbp/s bridging fabric
• Less than 4s latency
Protocols 802.1AB, 802.1D, 802.1Q, IEEE 802.2, 802.3ad
Management
• Server Intuitive graphical user interface and setup wizards • Embedded SNMP v1, v2 • Command Line Interface • Any uplink port can be used as a dedicated mirrored port from the port(s)
Security • LDAP, SSL, Role-based management
![Page 17: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/17.jpg)
Supported Servers and NICs
• NICs− HP NC325m PCI Express Quad Port 1Gb Server Adapter 416585-B21
− HP NC326m PCI Express Dual Port 1Gb Server Adapter 406771-B21
− HP NC360m Dual Port 1GbE BL-c Adapter 445978-B21
− HP NC364m Quad Port 1GbE BL-c Adapter 447883-B21
− HP NC373m PCI Express Dual Port Multifunction Gigabit Server Adapter 406770-B21
− HP NC532m PCI Express Dual Port 10Gb Server Adapter 467799-B21
Servers 1Gb LOM 10Gb LOM 1Gb NIC 10Gb NIC
HP ProLiant BL260c G5 Yes N/A All HP NC532m
HP Proliant BL2x220c G5 Yes N/AAll Except:
HP NC325m, HP NC364mHP NC532m
HP ProLiant BL460c Yes N/A All HP NC532m
HP ProLiant BL465c Yes N/A All HP NC532m
HP ProLiant BL465c G5 Yes N/A All HP NC532m
HP ProLiant BL480c Yes N/A All HP NC532m
HP ProLiant BL680c G5 Yes N/A All HP NC532m
HP ProLiant BL685c Yes N/A All HP NC532m
HP ProLiant BL685 G5 Yes N/A All HP NC532m
HP Proliant BL495c G5 N/A Yes All HP NC532m
![Page 18: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/18.jpg)
VC Flex-10 Order, configuration & licensing• HP VC Flex-10 10Gb Ethernet
module− 455880-B21—HP Virtual Connect
Flex-10 10Gb Ethernet Module for c-Class BladeSystem
• CX4 cable− 444477-Bxx
• B21 HP .5m 10GbE CX4 Cable• B22 HP 1m 10GbE CX4 Cable• B23 HP 3m 10GbE CX4 Cable• B27HP 15m 10GbE CX4 Cable
• VC Flex-10 firmware rules− VC Flex-10 firmware is VC 2.00
− VC 2.00 supports Flex-10 and existing Virtual Connect modules in a single enclosure
− VC 1.3x firmware will be concurrently maintained for at least six months
• SFP+ connectors− 455883-B21— HP BladeSystem
10Gb SR SFP+− 455886-B21 — HP BladeSystem
10Gb LR SFP+ − 455889-B21 — HP BladeSystem
10Gb LRM SFP+
• SFP+ copper cable− 487649-B21 — HP 0.5m SFP+
10GbE Copper Cable− 487652-B21 — HP 1m SFP+
10GbE Copper Cable− 487655-B21 — HP 3m SPR+
10GbE Copper Cable− 487658-B21 — HP 7m SPR+
10GbE Copper Cable
![Page 19: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/19.jpg)
Making your customer successful with VC Care Pack Services Virtual Connect Flex-10
• Ensuring a successful configuration− HP Enhanced Network Installation and
Startup Service (UE603E): Configuration of VC domains, configure bandwidth for server profiles and “preferred” and “max” connection speeds for each net
− Other HW install services available• Customer training to ensure success
− Virtual Connect for HP BladeSystem – 2 day training care pack (H837S)
• Technical Support for issues− 24x7 4 hour onsite support – Virtual
Connect is covered as part of Enclosure HW Support care pack (UE479E for c7000)
![Page 20: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/20.jpg)
HP Virtual Connect 4Gb Fibre Channel Module for BladeSystem c-Class
![Page 21: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/21.jpg)
HP Virtual Connect 4Gb FC ModuleModel comparison
4Gb Virtual Connect FC Module 409513-B21
Virtual Connect 4Gb FC Module 409513-B22
Port Speed Up to 4Gb Up to 4Gb
Uplinks 4 4
NPIV Logins per Uplink
16255 (maximum of 128 per server)
NPIV Logins per Downlink
12 128 (4Gb HBA Max)
Min Oversubscription
4:1 4:1
SAN Fabrics Supported
4 4
Direct Fibre Channel
No No
SAN Monitoring Physical HBA Physical HBA
Management VCM, VCEM VCM, VCEMVC 1.30 or later required
![Page 22: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/22.jpg)
HP Virtual Connect 4Gb FC Module• 16x 4Gb FC – Connects to one HBA port in each HH blade
server bay
• Mgmt Interfaces to Onboard Administrator
4x 1/2/4 Gb FC (SFP)Connects to data center Fibre Channel switches
Port LEDsLink and Activity
Port Number & Status IndicatorsIndicates whether a port is configured (green) or highlighted (blue)
MidPlane
Module LEDsHealth and UID
![Page 23: 17. Virtual Connect Stefan Jönsson.ppt](https://reader035.vdocument.in/reader035/viewer/2022081422/5568e2bcd8b42a287a8b4b35/html5/thumbnails/23.jpg)
Server Side NPIV and Virtual Machines
VHBA-1
HBA
4Gb Virtual Connect FC
409513-B21
VHBA-2 VHBA-3
VM1 VM2 VM3
Single WWN
VHBA-1
HBA
Virtual Connect 4Gb FC
409513-B22
VHBA-2 VHBA-3
VM1 VM2 VM3
Single Port
Multiple WWNs
Server Blade Server Blade
Today – Target Side NPIV Only SAN Manager can only see Physical HBA
Server Side NPIV
SAN’s can see and manage VM HBA’s. Can provide QoS to specific VMs
Vol 2
Vol 3Vol 1