2-way cartridge valves - directional function ra cartridge ... · pdf file2-way cartridge...
TRANSCRIPT
RA 21 010/06.98
1/36
Sizes 16 to 160 up to 6,604 GPM (25,000 L/min) up to 6,092 PSI (420 bar)
2-way cartridge valves - directional functionCartridge valve model LC...Control cover model LFA...
K 3311/10 K 3315/10
Features:– Valve poppet with or without damping
nose
– 2 area ratios
– 4 different control spring options
– 4 stroke limiting options
– Control cover with built-in poppet valve
– Control cover with built-in shuttle valve
– Control cover for mounting directionalspool valves with or without built-inshuttle valve
– Control cover for mounting directionalpoppet valves with or without built-inshuttle valve
K 3314/3
RA21 010/06.98Replaces: 81 010
Contents
Description Page
Functional description 2
Cartridge valve model LC:
– Ordering details 2
– Installation dimensions 3; 4
– Technical data 5; 6
– Operating curves 7
– Spare parts:
• Seal kits 7
• Compression springs 8
Control cover model LFA:
– Ordering details
• Model code 9
• Pilot valves 10
• Basic functions 10
– Orifices 11
– Spare parts
• R-rings 11
• Seal kits 12
• Mounting bolts 12
Cartridge valve model LC..., series 6X; 2X(sizes 40 to 160)
H/A 5455/96
Cartridge valve model LC..., series 7X(sizes 16 to 32)
Control cover model LFA...D.6X/ Control cover model LFA...WE...
Description Page
Ordering details, symbols and control cover unit dimensions:
– Model ...D... 13
– Model ...H... 14; 15
– Model ...G... 16; 17
– Models ...R...; ...RF...; ...R2... 18; 19
– Model ...WE... 20; 21
– Models ...WEM...; ...WE.8... 22; 23
– Models ...WECA..; ...WEA9... 24; 25
– Model ...GW... 26; 27
– Model ...KW... 28; 29
– Model ...E... 30
– Model ...EH2... 31
– Model ...EW... 32; 33
Inductive limit switch:
– Electrical connections 34
– Plug-in connector 35
RA 21 010/06.98
2/36
Nominal size 16 = 16Nominal size 25 Series 7X = 25Nominal size 32 = 32Nominal size 40 = 40Nominal size 50 = 50Nominal size 63 Series 6X = 63Nominal size 80 = 80Nominal size 100 =100Nominal size 125 =125Nominal size 160 Series 2X =160
Area ratio 2:1 (annulus area = 50%) = AArea ratio 14.3:1 (annulus area = 7%) = B
Cracking pressure approx. 0 PSI (0 bar) (without spring) = 00Cracking pressure approx. 7.25 PSI (0.5 bar) = 05Cracking pressure approx. 14.5 PSI (1.0 bar) = 10Cracking pressure approx. 29 PSI (2 bar) = 20Cracking pressure approx. 43.5 PSI (3 bar) (only size 125) = 30Cracking pressure approx. 58 PSI (4 bar) = 401) For exact values. see page 5 and 6
Functional description, section
2 way cartridge valves are designed as inserts for compactmanifold control blocks. The "logic" cartridge with ports A and B isinstalled within a cavity with dimensions conforming toDlN ISO 7368. A cover is mounted above the insert which functionsas a seal and control interface for the valve poppet. Dependent ontype of cover and optional pilot valve, the cartridge valve canperform directional, throttle, pressure or combinations of thesefunctions. The circuit designer can select type and size of cartridgevalve with respect to given flows within an application. Aneconomical use of space, reduction of external fluid connectionscan be achieved via logic systems.
Directional Function2 way cartridge valves consists basically of the cover (LFA...)...(1)and insert (LC...)...(2). The cover contains the control drillings,orifices, shuttles, and external directional valves as determined onspecific model types. Stroke limiting functions and directionalvalve pilot functions are also available for throttling and/orswitching functions. The insert (2) includes a bushing (3)..cap (4),sizes 16 ... 32, and a poppet (5). The poppet (5) may include adampening nose (6) or not (7). The control spring (8) provides abiasing force to close the poppet as forces A1 + A2 correspondsX = A3.
Function2 way cartridge valves are similar to check valves where a biasingspring tries to hold a poppet closed against a flow stream untilsufficient forces exist to open the poppet. Rexroth defines area A1as 100%. The annulus at "B", area A2, can be either 7% or 50%dependent on model selected. An area ratio between A1: A2 canbe either 2:1 or 14.3:1. Area A3 is the sum of A1 and A2 and ispiloted from the source "x". The pilot signal can originate from "A","B" or other external source. Since A1 + A2 equals A3, the biasing
no code = NBR sealsV = FPM seals
(other seals on request)
Attention!The compatibility of the seals andfluid has to be taken into account!
7X = (sizes 16 to 32) Series 70 to 79(70 to 79: unchanged
installation and connection dimensions)6X = (sizes 40 to 100) Series 60 to 69
(60 to 69: unchangedinstallation and connection dimensions)
2X = (sizes 125 and 160) Series 20 to 29(20 to 29: unchanged
installation and connection dimensions)
E = Valve poppet without damping noseD = Valve poppet with damping nose
LC
B
A
Area ratio
A1 : A2 = 2 : 1
Version …A..E../…
B
A
Area ratio
A1 : A2 = 14.3 : 1
Version…B..E../…
B
A
B
A
Area ratio
A1 : A2 = 2 : 1
Version…A..D../…
Area ratio
A1 : A2 = 14.3 : 1
Version…B..D../…
Symbols: cartridge valves (for versions see ordering details)
Ordering details: cartridge valve (without control cover)
1)
Without damping nose With damping nose
spring is necessary to close the poppet in the event all hydraulicforces are balanced.
Basically:Pressure upon areas A1 and A2 open the valve. Pressure uponarea A3 plus the spring close the valve. The resultant force (ofopening and closing forces) determines the spool position (5; 7)of the 2-way cartridge valve.
2-way cartridge valves may flow A to B or B to A. When the pilotoil for area A3 is obtained from port B external port A is closed,leak free.
Model LFA…D../FX..
Model LC.. .. ../..AB
ED
X**X
XB
A
A1 100%
A2 7% (50%)
A3 ↓ 107% (150%)
↓
↓
X
1
43
2
8
6
5; 7
B
A
RA 21 010/06.98
3/36
R 8max
R 16max
R0.0079 max.
R0.039
Ø62H110.
177+
0.00
4
Ø1,58 max(X,Y,Y1)
R 20zR 12z
ØD2
ØD4H70,05 A
ØD
3(D
3*)
H8
H1(
H1*
)
A
x
ØD1H7
WT
z
15° A
y
15°
z
H7
H6 H3±
0.00
39H
5
H9
By
H2+
0.00
39
7 1
17423
Cavity and porting pattern to DIN 24 342 (with the exception of sizes 125 and 160):dimensions in English Units (see table on Page 4, top)
Z1
X Y
Z2
L2±0
.011
8
L1
8xD5; H4
ØD7H13; 0.39 (10)
ØD6 max.(X, Y, Z1, Z2)
35° 22.5°
45°5
Size 125
Sizes 80, 100
ØD7H13; 0.39 (10)
L1
L5±0.0079
L2±0.0079
Z1
X Y
Z2
L3±0
.007
9
L1
L4±0
.007
9L4
±0.0
079
L4±0.0079L4±0.0079ØD6 max.
(X, Y, Z1, Z2)
4x D5; H4†
L2±0
.007
9
5
6Sizes 16 to 63
Size 160
Y1
XY
Ø0.354;0.39
12xM42; 2.91 Ø0.354;0.39
45°
1,77±0.0079
45°
2,36±0.0079
8.47
±0.0
079
8.47
±0.0
079
15.7
5±0.
0118
18.9
22.5°
22.5
°
45°
45°
5
5
Y1
X
Y
11.8
1±0.
0118
14.9
6
Ø9; 0.35 (9)
Ø1.26 max.(X, Y, Y1)
Ø0.35;0.398xM36; 2.44
22.5°
45°
1.18±0.0079
45°
1.77±0.0079
6.5±
0.00
796.
5±0.
0079
5
= Rmax4 = Rmax8 = Rz10x y z
1 Depth of fit
2 Reference dimension
3 For diameters of port B other than ØD3 or (ØD3*), thedistance from the cover mounting surface to center of theport must be calculated.
4 Port B may be moved about the central axis of port A.However, care must be taken that the mounting holes andcontrol holes are not damaged.
5 Locating pin holes
6 Note on porting pattern size 1 Length L1 (holes on x–y axis)is 3.15 inches in control covers with built on directional valve.
7 With Ø ≤ 1.77 inches → fit permissible!+0.0154 0
RA 21 010/06.98
4/36
Size 16 25 32 40 50 63 80 100 125 160ØD1 1.26 1.77 2.36 2.95 3.54 4.72 5.71 7.09 8.86 11.8ØD2 0.63 0.98 1.26 1.58 1.97 2.48 3.15 3.94 5.91 1) 7.87 1)
ØD3 0.63 0.98 1.26 1.58 1.97 2.48 3.15 3.94 4.92 7.87(ØD3*) 0.98 1.26 1.58 1.97 2.48 3.15 3.94 4.92 5.91 9.84 1)
ØD4 0.98 1.34 1.77 2.17 2.68 3.54 4.33 5.31 7.87 10.63ØD5† 5/16" 1/2" 5/8" 3/4" 3/4" 1-1/4" 1" 1-1/4" – –ØD6 1) 0.158 0.236 0.315 0.394 0.394 0.472 0.63 0.787 – –ØD7H13 0.158 0.236 0.236 0.236 0.315 0.315 0.394 0.394 – –
H1 1.34 1.73 2.05 2.52 2.84 3.74 5.12 6.1 7.56 10.55(H1*) 1.16 1.6 1.89 2.32 2.58 3.41 4.72 5.59 7.09 9.57H2 2.21 2.84 3.35 4.13 4.8 6.1 8.07 9.65 11.8+0.006 16.7+0.006
H3 1.69 2.28 2.76 3.43 3.94 5.12 6.89±0.008 8.27±0.008 10.12±0.02 14.57±0.02
H4 0.79 0.984 1.38 1.77 1.77 2.56 1.97 2.48 – –H5 0.433 0.472 0.512 0.591 0.669 0.787 0.98 1.14 1.22 1.77H6 0.079 0.098 0.098 0.118 0.118 0.158 0.197 0.197 0.28±0.02 0.32±0.02
H7 0.787 1.18 1.18 1.18 1.38 1.58 1.58 1.97 1.58 1.97H8 0.079 0.098 0.098 0.118 0.158 0.158 0.197 0.197 0.217±0.008 0.22±0.008
H9 0.012 0.039 0.059 0.098 0.098 0.118 0.177 0.177 0.079 0.079L1 2.56/3.15 3.35 4.02 4.92 5.51 7.09 9.84 11.8 – –L2 1.81 2.28 2.76 3.35 3.94 4.92 7.87 9.65 – –L3 0.91 1.14 1.38 1.67 1.97 2.46 – – – –L4 0.98 1.3 1.61 1.97 2.28 2.95 – – – –L5 0.413 0.63 0.669 0.91 1.18 1.5 – – – –W 0.002 0.002 0.004 0.004 0.004 0.0079 0.0079 0.0079 0.0079 0.0079
1) max. dim.† For applications with UNC thread bolts, use inch value.
Cavity and porting pattern to DIN 24 342 (with the exception of sizes 125 and 160):dimensions in English Units (inches)
Cavity and porting pattern to DIN ISO 7368 (with the exception of sizes 125 and 160):dimensions in Metric Units (millimeters)
Size 16 25 32 40 50 63 80 100 125 160ØD1 32 45 60 75 90 120 145 180 225 300ØD2 16 25 32 40 50 63 80 100 150 1) 200 1)
ØD3 16 25 32 40 50 63 80 100 125 200(ØD3*) 25 32 40 50 63 80 100 125 150 250 1)
ØD4 25 34 45 55 68 90 110 135 200 270ØD5 M8 M12 M16 M20 M20 M30 M24 M30 – –
ØD6 1) 4 6 8 10 10 12 16 20 – –ØD7H13 4 6 6 6 8 8 10 10 – –
H1 34 44 52 64 72 95 130 155 192 268(H1*) 29.5 40.5 48 59 65.5 86.5 120 142 180 243H2 56 72 85 105 122 155 205 245 300+0.15 425+0.15
H3 43 58 70 87 100 130 175±0.2 210±0.2 257±0.5 370±0.5
H4 20 25 35 45 45 65 50 63 – –H5 11 12 13 15 17 20 25 29 31 45H6 2 2.5 2.5 3 3 4 5 5 7±0.5 8±0.5
H7 20 30 30 30 35 40 40 50 40 50H8 2 2.5 2.5 3 4 4 5 5 5.5±0.2 5.5±0.2
H9 0.5 1 1.5 2.5 2.5 3 4.5 4.5 2 2L1 65/80 85 102 125 140 180 250 300 – –L2 46 58 70 85 100 125 200 245 – –L3 23 29 35 42.5 50 62.5 – – – –L4 25 33 41 50 58 75 – – – –L5 10.5 16 17 23 30 38 – – – –W 0.05 0.05 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2
1) max. dim.
RA 21 010/06.98
5/36
R 8max
R 16max
R0.2 max.R1
Ø62H114,
5+0.
1
Ø40 max(X,Y,Y1)
R 20zR 12z
ØD2
ØD4H70.05 A
ØD
3(D
3*)
H8
H1(
H1*
)
A
x
ØD1H7
WT
z
15° A
y15
°
z
H7
H6 H
3±0.
1H
5
H9
By
H2+
0.1
7 1
17423
Z1
X Y
Z2
L2±0
.3
L1
8xD5; H4
ØD7H13; 10
ØD6 max.(X,Y,Z1,Z2)
35° 22,5°
45°5
Size 125
Sizes 80, 100
L1
L5±0.2
L2±0.2
Z1
X Y
Z2
L3±0
.2
L1
L4±0
.2L4
±0.2
L4±0.2L4±0.2 ØD6 max.(X,Y,Z1,Z2)
4x D5; H4ØD7H13; 10
L2±0
.2
5
6Sizes 16 to 63
Size 160
Y1
XY
Ø9;10
12xM42; 74 Ø9;10
45°
45±0.2
45°
60±0.2
215±
0.2
215±
0.2 40
0±0,
3
480
22.5°
22.5
°
45°
45°
5
5
Y1
X
Y
300±
0.3
380
Ø9;10
Ø32 max.(X,Y,Y1)
Ø9;10 8xM36; 62
22.5°
45°
30±0.2
45°
45±0.2
165±
0.2
165±
0.2
5
= Rmax4 = Rmax8 = Rz10x y z
Cavity and porting pattern to DIN ISO 7368 (with the exception of sizes 125 and 160):dimensions in Metric Units (see table on Page 4, bottom)
1 Depth of fit
2 Reference dimension
3 For diameters of port B other than ØD3 or (ØD3*), thedistance from the cover mounting surface to center of theport must be calculated.
4 Port B may be moved about the central axis of port A.However, care must be taken that the mounting holes andcontrol holes are not damaged.
5 Locating pin holes
6 Note on porting pattern size 1 Length L1 (holes on x–y axis)is 80 mm in control covers with built on directional valve.
7 With Ø ≤ 45 mm → fit H8 permissible!
RA 21 010/06.98
6/36
Nominal size 16 25 32 40 50 63 80 100 125 160
Area A1 in in2 LC..A.. 0.293 0.66 1.05 1.43 2.57 3.55 5.88 9.86 14.73 24.89
LC..B.. 0.412 0.888 1.47 2.01 3.55 4.99 8.18 13.81 20.72 34.84
Area A2 in in2 LC..A.. 0.147 0.293 0.526 0.715 1.25 1.75 2.92 4.87 7.44 12.38
LC..B.. 0.028 0.067 0.104 0.14 0.268 0.31 0.611 0.915 1.441 2.43
Area A3 in in2 LC..A.. 0.44 0.955 1.578 2.147 3.818 5.3 8.795 14.73 22.17 37.28LC..B..
Stroke in inches LC..E.. 0.354 0.46 0.551 0.472 0.63 0.748 0.945 1.181 1.496 4.969
LC..D.. 0.354 0.46 0.551 0.63 0.787 0.945 1.181 1.496 1.89 2.556
Control volume in in3 LC..E.. 0.156 0.44 0.873 1.013 2.404 3.966 8.3 17.4 33.2 73.4
LC..D.. 0.156 0.44 0.873 1.355 3.008 5.004 10.37 22.03 41.9 95.37
Theoretical pilot flow at a LC..E.. 4.068 11.44 22.72 26.42 62.35 103 215.6 451.7 862.3 1907
switching time of 10 ms in GPM LC..D.. 4.068 11.44 22.72 35.14 78.2 130 269.5 572.2 1089 2477
Weight in lbs Cartridge valve 0.551 1.102 2.42 3.967 8.375 15.43 28.65 29.51 96.98 165.3
Control cover 2.645 5.069 8.816 16.31 23.14 46.28 59.51 92.57 176.3 330.6
Cracking pressure in PSI LC..A 00.. 0.29 0.363 0.725 0.725 0.725 1.015 1.015 1.45 2.18 2.18
LC..A 05.. 5.076 5.076 5.221 6.237 6.527 6.092 6.382 6.238 6.238 6.528
LC..A 10.. 10.15 9.863 10.44 12.62 12.62 12.33 12.76 12.76 12.76 –
LC..A 20.. 29.44 31.62 30.75 25.09 25.24 24.66 25.38 25.38 25.53 28.14
LC..A 30.. – – – – – – – – 29.73 –
LC..A 40.. 50.76 56.67 55.12 50.62 48.59 48.15 45.4 44.09 – –
LC..B 00.. 0.203 0.29 0.508 0.508 0.508 0.725 0.725 1.015 1.45 1.45
LC..B 05.. 3.636 3.77 3.77 4.496 4.64 4.35 4.496 4.496 4.496 4.64
LC..B 10.. 7.11 7.252 7.397 8.99 9.14 8.85 9.14 9.14 8.99 –
LC..B 20.. 20.89 23.5 22.05 17.99 18.28 17.55 18.28 18.13 18.13 20.31
LC..B 30.. – – – – – – – – 21.03 –
LC..B 40.. 35.97 42.06 39.16 36.26 35.24 34.23 32.63 31.47 – –
LC..A 00.. 0.58 0.725 1.45 1.45 1.45 2.03 2.03 2.9 4.35 4.79
LC..A 05.. 10 11.31 10.44 12.47 13.49 12.33 12.76 12.76 12.47 13.2
LC..A 10.. 20.02 22.19 20.6 25.24 26.11 25.1 25.67 25.82 25.1 –
LC..A 20.. 58.74 71.22 61.64 50.18 52.2 49.89 51.2 51.34 50.76 56.57
LC..A 30.. – – – – – – – – 58.02 –
LC..A 40.. 101 126.8 110.2 101.5 100.1 97.18 91.38 89.93 – –
LC..B 00.. 3.48 3.626 7.252 7.252 7.252 11.6 10.15 14.5 21.76 21.76
LC..B 05.. 53.52 49.3 52.8 59.47 62.37 68.17 60.92 66.72 63.82 66.72
LC..B 10.. 107.8 97.03 105 118.9 121.8 139.2 121.8 136.3 129.1 –
LC..B 20.. 308.9 311.8 313.3 237.9 242.2 275.6 245.1 271.2 259.6 290.1
LC..B 30.. – – – – – – – – 300.2 –
LC..B 40.. 530.9 555.5 559.9 481.5 467 536.7 438 471.4 – –
2-way cartridge valve - directional function
Dire
ctio
n of
flow
A to
BD
irect
ion
of fl
ow
B to
A
Technical data (for applications outside these parameters, please consult us!) (Dimensions in English Units)Pressure fluid Mineral oil (HL, HLP) to DIN 51 524 1);
Fast bio-degradable pressure fluids to VDMA 24 5681) suitable for NBR and FPM seals (also see RA 90 221); HETG1); HEPG (polyglycol) 2);2) only suitable for FPM seals HEES (synthetic ester) 2); other fluids on request
Pressure fluid - temperature range °F – 4 to + 176
Viscosity range SUS 35 to 1760
Degree of contamination Maximum permissible degree of contamination of the fluid is toNAS 1638 class 9. Therefore, we recommend a filter with aminimum retention rate of ß
10 ≥ 75.
Max. operating pressure PSI 6092 (without built-on directional valve)for connections A, B, X, Z1, Z2 4569/5076/6092: p
max of the built-on directional spool valve
6092 pmax
of the built-on directional poppet valve
Operating pressure for connections Y PS Dependant up on to the tank pressure of the pilot valve
RA 21 010/06.98
7/36
Nominal size 16 25 32 40 50 63 80 100 125 160
Area A1 in cm2 LC..A.. 1.89 4.26 6.79 9.24 16.6 22.9 37.9 63.6 95 160.6
LC..B.. 2.66 5.73 9.51 12.95 22.9 32.2 52.8 89.1 133.7 224.8
Area A2 in cm2 LC..A.. 0.95 1.89 3.39 4.61 8.03 11.3 18.84 31.4 48 79.9
LC..B.. 0.18 0.43 0.67 0.9 1.73 2 3.94 5.9 9.3 15.7
Area A3 in cm2 LC..A.. 2.84 6.16 10.18 13.85 24.63 34.2 56.74 95 143 240.5LC..B..
Stroke in cm LC..E.. 0.9 1.17 1.4 1.2 1.6 1.9 2.4 3 3.8 5
LC..D.. 0.9 1.17 1.4 1.6 2 2.4 3 3.8 4.8 6.5
Control volume in cm3 LC..E.. 2.56 7.21 14.3 16.6 39.4 65 136 285 544 1203
LC..D.. 2.56 7.21 14.3 22.2 49.3 82 170 361 687 1563
Theoretical pilot flow at a LC..E.. 15.4 43.3 86 100 236 390 816 1710 3264 7218
switching time of 10 ms in L/min LC..D.. 15.4 43.3 86 133 296 492 1020 2166 4122 9378
Weight in kg Cartridge valve 0.25 0.5 1.1 1.8 3.8 7 13 27 44 75
Control cover 1.2 2.3 4 7.4 10.5 21 27 42 80 150
Cracking pressure in bar LC..A 00.. 0.02 0.025 0.05 0.05 0.05 0.07 0.07 0.1 0.15 0.15
LC..A 05.. 0.35 0.35 0.36 0.43 0.45 0.42 0.44 0.43 0.43 0.45
LC..A 10.. 0.7 0.68 0.72 0.87 0.87 0.85 0.88 0.88 0.88 –
LC..A 20.. 2.03 2.18 2.12 1.73 1.74 1.7 1.75 1.75 1.76 1.94
LC..A 30.. – – – – – – – – 2.05 –
LC..A 40.. 3.5 3.9 3.8 3.49 3.35 3.32 3.13 3.04 – –
LC..B 00.. 0.014 0.02 0.035 0.035 0.035 0.05 0.05 0.07 0.1 0.1
LC..B 05.. 0.25 0.26 0.26 0.31 0.32 0.3 0.31 0.31 0.31 0.32
LC..B 10.. 0.49 0.5 0.51 0.62 0.63 0.61 0.63 0.63 0.62 –
LC..B 20.. 1.44 1.62 1.52 1.24 1.26 1.21 1.26 1.25 1.25 1.4
LC..B 30.. – – – – – – – – 1.45 –
LC..B 40.. 2.48 2.9 2.7 2.5 2.43 2.36 2.25 2.17 – –
LC..A 00.. 0.04 0.05 0.1 0.1 0.1 0.14 0.14 0.2 0.3 0.33
LC..A 05.. 0.69 0.78 0.72 0.86 0.93 0.85 0.88 0.88 0.86 0.91
LC..A 10.. 1.38 1.53 1.42 1.74 1.8 1.73 1.77 1.78 1.73 –
LC..A 20.. 4.05 4.91 4.25 3.46 3.6 3.44 3.53 3.54 3.5 3.9
LC..A 30.. – – – – – – – – 4 –
LC..A 40.. 6.96 8.74 7.6 7 6.9 6.7 6.3 6.2 – –
LC..B 00.. 0.24 0.25 0.5 0.5 0.5 0.8 0.7 1 1.5 1.5
LC..B 05.. 3.69 3.4 3.64 4.1 4.3 4.7 4.2 4.6 4.4 4.6
LC..B 10.. 7.43 6.69 7.24 8.2 8.4 9.6 8.4 9.4 8.9 –
LC..B 20.. 21.3 21.5 21.6 16.4 16.7 19 16.9 18.7 17.9 20
LC..B 30.. – – – – – – – – 20.7 –
LC..B 40.. 36.6 38.3 38.6 33.2 32.2 37 30.2 32.5 – –
2-way cartridge valve - directional function
Dire
ctio
n of
flow
A to
BD
irect
ion
of fl
ow
B to
A
Pressure fluid Mineral oil (HL, HLP) to DIN 51 524 1);Fast bio-degradable pressure fluids to VDMA 24 568
1) suitable for NBR and FPM seals (also see RA 90 221); HETG1); HEPG (polyglycol) 2);2) only suitable for FPM seals HEES (synthetic ester) 2); other fluids on request
Pressure fluid - temperature range °C – 20 to + 80Viscosity range mm2/s 2.8 to 380
Degree of contamination Maximum permissible degree of contamination of the fluid is toNAS 1638 class 9. Therefore, we recommend a filter with aminimum retention rate of ß10 ≥ 75.
Max. operating pressure bar 420 (without built-on directional valve)for connections A, B, X, Z1, Z2 315 / 350 / 420 : p
max of the built-on directional spool valve
420 pmax
of the built-on directional poppet valve
Operating pressure for connections Y bar Dependant to the tank pressure of the pilot valve
Technical data (for applications outside these parameters, please consult us!) (Dimensions in Metric Units)
RA 21 010/06.98
8/36
Directional valve functionWith damping nose
Flow qv in GPM (L/min)
With damping nose
With damping nose
Without damping nose
Without damping nose
Without damping nose
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
Operating curves, measured at ν = 190 SUS (41 mm2/s) and t = 122 °F (50°C)
Seal kit Part numberfor NBR FPM
LC 63 ... 6X 00314057 00314066LC 80 ... 6X 00314058 00314067
LC 100 ... 6X 00314059 00314068LC 125 ... 2X 00314060 00314069LC 160 ... 2X 00314497 00314388
Seal kits for cartridge valves model LC... (sizes 16 to 160)
Seal kit Part numberfor NBR FPM
LC 16 .. 7X/… 00313104 00313107LC 25 .. 7X/… 00313105 00313108LC 32 .. 7X/… 00313106 00313109LC 40 .. 6X/… 00314055 00314064LC 50 .. 6X/… 00314056 00314065
Flow qv in GPM (L/min)
Flow qv in GPM (L/min) Flow qv in GPM (L/min)
Flow qv in GPM (L/min) → Flow qv in GPM (L/min) →
size 16 size 25 size 32
size 40 size 50
size
63
size 16 size 32
size 40 size 50 size 63
size 80 size 100 size 160size 125 size 80 size 100 size 125
size
160
0
(2)
(4)
(6)
(8)
(10)
(200) (400) (600) (800) (1,000) (1,200)
29
58
87
116
145
0
53 106 159 212 265 318
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
0 (500) (1,000) (1,500) (2,000) (2,500) (3,000)
(2)
(4)
(6)
(8)
(10)
0
132 264 396 528 660 792
29
58
87
116
145
0 (500) (1,000) (1,500) (2,000) (2,500) (3,000)
(2)
(4)
(6)
(8)
(10)
0
29
58
87
116
145
132 264 396 528 660 792
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
29
58
87
116
145
0 (2,000) (6,000) (10,000) (14,000) (18,000)
(2)
(4)
(6)
(8)
(10)
(4,000) (8,000) (12,000) (16,000) (20,000)
0
530 1,590 2,650 3,710 4,7701,060 2,120 3,180 4,240 5,300
(2)
(4)
(6)
(8)
(10)
0 (2,000) (6,000) (10,000) (14,000) (18,000)(4,000) (8,000) (12,000) (16,000) (20,000)
0
29
58
87
116
145
530 1,590 2,650 3,710 4,7701,060 2,120 3,180 4,240 5,300
0
(2)
(4)
(6)
(8)
(10)
(200) (400) (600) (800) (1,000) (1,200)0
29
58
87
116
145
53 106 159 212 265 318
size 25
RA 21 010/06.98
9/36
Compression springs for cartridge valves model LC... (size 16 to 160): dimensions in inches
* A or B; ** E or D
Size Model Spring dimensions Partin inches no.
16 LC 16 * 05 ** 7X 0.413/0.032x1.654/0.276 00002110LC 16 * 10 ** 7X 0.413/0.039x1.654/0.335 00002111LC 16 * 20 ** 7X 0.402/0.051x1.595/0.315 00062747LC 16 * 40 ** 7X 0.394/0.063x1.504/0.354 00062753
25 LC 25 * 05 ** 7X 0.63/0.055x2.402/0.413 00002114LC 25 * 10 ** 7X 0.622/0.063x2.402/0.374 00002115LC 25 * 20 ** 7X 0.602/0.089x2.165/0.315 00062762LC 25 * 40 ** 7X 0.587/0.106x2.102/0.335 00062764
32 LC 32 * 05 ** 7X 0.807/0.071x3.11/0.453 00002116LC 32 * 10 ** 7X 0.787/0.079x3.11/0.374 00002117LC 32 * 20 ** 7X 0.772/0.11x0.736/0.295 00062813LC 32 * 40 ** 7X 0.768/0.126x2.795/0.335 00062783
40 LC 40 * 05 ** 6X 1.083/0.098x4.252/0.532 00002119LC 40 * 10 ** 6X 1.083/0.11x4.252/0.413 00002120LC 40 * 20 ** 6X 1.063/0.126x4.252/0.374 00002121LC 40 * 40 ** 6X 1.024/0.158x4.1/0.433 00002122
50 LC 50 * 05 ** 6X 1.417/0.126x5.118/0.413 00002123LC 50 * 10 ** 6X 1.398/0.142x5.118/0.354 00002124LC 50 * 20 ** 6X 1.358/0.177x5.118/0.472 00002125LC 50 * 40 ** 6X 1.319/0.221x4.606/0.394 00002126
Size Model Spring dimensions Partin inches no.
63 LC 63 * 05 ** 6X 1.713/0.142x6.496/0.354 00002354LC 63 * 10 ** 6X 1.693/0.158x6.496/0.276 00002355LC 63 * 20 ** 6X 1.654/0.197x6.457/0.354 00002358LC 63 * 40 ** 6X 1.595/0.248x6.22/0.433 00002361
80 LC 80 * 05 ** 6X 2.244/0.197x7.874/0.413 00002357LC 80 * 10 ** 6X 2.224/0.221x7.874/0.335 00002359LC 80 * 20 ** 6X 2.165/0.276x7.913/0.453 00002362LC 80 * 40 ** 6X 2.087/0.354x6.93/0.394 00002365
100 LC 100 * 05 ** 6X 2.913/0.276x9.843/0.551 00002363LC 100 * 10 ** 6X 2.874/0.315x9.882/0.492 00002364LC 100 * 20 ** 6X 2.835/0.354x9.882/0.413 00002366LC 100 * 40 ** 6X 2.717/0.453x8.74/0.394 00002367
125 LC 125 * 05 ** 2X 3.386/0.315x12.13/0.492 00011090LC 125 * 10 ** 2X 3.346/0.354x12.21/0.413 00002649LC 125 * 20 ** 2X 3.168/0.433x12.21/0.492 00002454LC 125 * 30 ** 2X 3.15/0.551x10.04/0.394 00002650
160 LC 160 * 05 ** 2X 4.429/0.394x16.46/0.453 00011097LC 160 * 20 ** 2X 4.17/0.63x14.37/0.433 00011232
Compression springs for cartridge valves model LC... (size 16 to 16): dimensions in millimeters
* A or B; ** E or D
Size Model Spring dimensions Partin inches no.
16 LC 16 * 05 ** 7X 10.5 / 0.8 x 42 / 7 00002110LC 16 * 10 ** 7X 10.5 / 1 x 42 / 8.5 00002111LC 16 * 20 ** 7X 10.2 / 1.3 x 40.5 / 8 00062747LC 16 * 40 ** 7X 10 / 1.6 x 38.2 / 9 00062753
25 LC 25 * 05 ** 7X 16 / 1.4 x 61 / 10.5 00002114LC 25 * 10 ** 7X 15.8 / 1.6 x 61 / 9.5 00002115LC 25 * 20 ** 7X 15.3 / 2.25 x 55 / 8 00062762LC 25 * 40 ** 7X 14.9 / 2.7 x 53.4 / 8.5 00062764
32 LC 32 * 05 ** 7X 20.5 / 1.8 x 79 / 11.5 00002116LC 32 * 10 ** 7X 20 / 2 x 79 / 9.5 00002117LC 32 * 20 ** 7X 19.6 / 2.8 x 69.5 / 7.5 00062813LC 32 * 40 ** 7X 19.2 / 3.2 x 71 / 8.5 00062783
40 LC 40 * 05 ** 6X 27.5 / 2.5 x 108 / 13.5 00002119LC 40 * 10 ** 6X 27.5 / 2.8 x 108 / 10.5 00002120LC 40 * 20 ** 6X 27 / 3.2 x 108 / 9.5 00002121LC 40 * 40 ** 6X 26 / 4 x 104 / 11 00002122
50 LC 50 * 05 ** 6X 36 / 3.2 x 130 / 10.5 00002123LC 50 * 10 ** 6X 35.5 / 3.6 x 130 / 9 00002124LC 50 * 20 ** 6X 34.5 / 4.5 x 130 / 12 00002125LC 50 * 40 ** 6X 33.5 / 5.6 x 117 / 10 00002126
Size Model Spring dimensions Partin inches no.
63 LC 63 * 05 ** 6X 43.5 / 3.6 x 165 / 9 00002354LC 63 * 10 ** 6X 43 / 4 x 165 / 7 00002355LC 63 * 20 ** 6X 42 / 5 x 164 / 9 00002358LC 63 * 40 ** 6X 40.5 / 6.3 x 158 / 11 00002361
80 LC 80 * 05 ** 6X 57 / 5 x 200 / 10.5 00002357LC 80 * 10 ** 6X 56.5 / 5.6 x 200 / 8.5 00002359LC 80 * 20 ** 6X 55 / 7 x 201 / 11.5 00002362LC 80 * 40 ** 6X 53 / 9 x 176 / 10 00002365
100 LC 100 * 05 ** 6X 74 / 7 x 250 / 14 00002363LC 100 * 10 ** 6X 73 / 8 x 251 / 12.5 00002364LC 100 * 20 ** 6X 72 / 9 x 251 / 10.5 00002366LC 100 * 40 ** 6X 69 / 11.5 x 222 / 10 00002367
125 LC 125 * 05 ** 2X 86 / 8 x 308 / 12.5 00011090LC 125 * 10 ** 2X 85 / 9 x 310 / 10.5 00002649LC 125 * 20 ** 2X 83 / 11 x 310 / 12.5 00002454LC 125 * 30 ** 2X 80 / 14 x 255 / 10 00002650
160 LC 160 * 05 ** 2X 112.5 / 10 x 418 / 11.5 00011097LC 160 * 20 ** 2X 106 / 16 x 365 / 11 00011232
RA 21 010/06.98
10/36
Nominal size Model Series
16 25 32 40 50 63 80 100 125 160 A B P T X F Z1x x x 7X
x x x x x 6Xx x 2X
x Dx x x x x x x x x x D F xx x x x H1 F xx x x x x x x x x x H2 F xx x x x H3 F xx x x x x x x x H4 F xx x x x x x x x G x x x
x x x x x x x R x x x
x x RF x x xx x x x x R2 x x x
x x x x x x x x WEA x x xx x x x x x x x WEB x x xx x x WEMA x x x
x x x x x WEA8 x x xx x x WEMB x x x
x x x x x WEB8 x x xx x x WECA x x x x
x x x x x WEA9 x x x xx x x x x x x x GWA x x xx x x x x x x x GWB x x xx x x x x x x x KWA x x x xx x x x x x x x KWB x x x xx x x x x x E x x D Q . G24 F xx x x x x x EH2 x x D Q . G24 F xx x x x x x EWA x x D Q . G24 x x xx x x x x x EWB x x D Q . G24 x x x
Area
ratio
Cra
ckin
gpr
essu
re
Dam
ping
Rem
ote
cont
rol p
ort
Electricalmonitoringof closedposition Pr
essu
reflu
idO
rder
ing
deta
ils c
an b
e fo
und
on th
e pa
ges
cove
ring
the
indi
vidu
al c
ontr
olco
ver
varia
tions
LFA1 2 3 4 1) 5 2) 6 3) 7 4) 8 9 10 11 12 13 14 15 16 17
x = available
1) 7X = series 70 to 79,6X = series 60 to 69 and2X = series 20 to 29 : (installation andconnection dimensions remain unchanged)
2) CA = 2 : 1 (area ratio A1 : A2)CB = 14.3 : 1 (area ratio A1 : A2)CD = 0 %
In control covers with electrical monitoringof the closed position (incl. limit switch) themodel code includes the model of the controlcover and that of the cartridge valve.3) 10 = 14.5 PSI (1.0 bar) cracking pressure
20 = 29 PSI (2.0 bar) cracking pressure40 = 58 PSI (4.0 bar) cracking pressure
4) D = Valve poppet of cartridge element with damping nose5) Sequence of orifices when ordering and for representation in
symbols and on circuits.
See pages on individual control covers and page 11 forfurther information (orifice characteristic curves).
Symbol incircuit
Symbol inordering code
This orifice is a selected orifice. Ifrequired, the correct model codemust be entered with the orifice -diameter in 1/10 mm in the orderingcode.
Example: A12 = orifice with diameter1.2 mm in port A.
For pilot valves see page 10!
A12A1.2
General notes on the ordering details for control covers5)
Orifices in port
Symbol incircuit
Symbol inordering code
X12
This orifice is an installed orifice, it isstandard type code is required.(orifice - diameter in 1/10 mm)
Symbol incircuit
Symbol inordering code
This orifice is drilled. Type code isrequired. (orifice - diameter in mm)
Ø 0.047 in (1.2 mm)
RA 21 010/06.98
11/36
Note:By combining a 2-way cartridge valve with a pilot valve, variousvalve functions may be created. The following components, withporting pattern D03 (up to size 63) and D05 (size 80 to 100)DIN 24 340 may be considered.
Pilot valves must be ordered separately.For further details see relevant data sheet.Valve mounting bolts are included within the control cover scopeof supply.
General notes on the ordering details for control covers (pilot valves)
XB
A
Z1Z.. X..
Z2
XB
A
Z1
Z12X..
YF**
Symbols (basic symbols)LFA..D../F..Control cover with remote control portSizes 16 to 160
LFA..G../...Control cover with built-in shuttle valveSizes 16 to 100
LFA..H2-../F...Control cover with stroke limiter,with remote control portSizes 16 to 160
X**X
XB
A
X**X
XB
A
LFA..R../...Control cover with integrated hydraulicallyoperated pilot valve (directional poppet valve)Sizes 25 to 100
LFA..WEMA-7X/...; LFA..WEA8-6X/...Control cover for mounting a directionalspool or poppet valve with control port forswitching a 2nd valveSizes 16to 63
XB
A
Y
A
a
B
P TP** T**
F**Z2 Z1X
B
A
Y
A
a
B
P TP** T** A**
LFA..WECA-7X/...; LFA..WEA9-6X/...Control cover for mounting a directionalspool valve as a check valve circuitSizes 16 to 100
LFA..KWA../...Control cover for mounting a directional spoolor poppet valve, with built-in shuttle valve asa check valve circuitSizes 16to 100
LFA..GWA../...Control cover for mounting a directional spoolor poppet valve, with built-in shuttle valveSizes 16 to 100
XB
A
Y
A
a
B
P TP** T**A** B**
Z1 XB
A
Y
A
a
B
P TP** T** A**
Z1B
A
Y
A
a
B
P TP.. A**
Z1X..
X
LFA..E../...DQ.G24FControl cover with electrical monitoringof closed position including cartridgeelementSizes 16 to 63
LFA..EH2-../…DQ.G24FControl cover with electrical monitoring ofclosed position and stroke limiter includingcartridge elementSizes 16 to 63
X**X
XB
A
X**X
XB
A XB
A
Y
A
a
B
P TP** T** A**
LFA..WEA../...Control cover for mounting a directionalspool or poppet valveSizes 16 to 100
Control cover with electrical monitoring ofclosed position, for mounting a directionalspool valveSizes 16to 63
LFA..EWA../…DQ.G24…
Page 13 Pages 14; 15 Pages 16; 17
Pages 18; 19 Pages 20; 21 Pages 22; 23
Pages 24; 25 Pages 26; 27 Pages 28; 29
Page 30 Page 31 Pages 32; 33
AB
Size
4WE 6 D…6X/E WE , WE 8, GW ,
KW , EW, WEM
3WE 6 A…6X/E WEA 9, WECA
4WE 10 D…3X/C
3WE 10 A…3X/C WEA 9
Control covermodel
Directional spoolvalve (wet pin)
Datasheet no.
6 23 178
AB
AB
WE , GW , KWAB
AB
ABAB
AB
10 23 316
Size
M-3SED 6 ../350… 22 049 WEA, WEA8, GWA
M-3SEW 6 ../420… 22 058 KWA, EWA, WEMA
M-3SED 10 ../350… 22 045 WEA, GWA
M-3SEW 10 ../420… 22 075 KWA
Control covermodel
Directional poppetvalve
Datasheet no.
6
10
UCUCUCUC
RA 21 010/06.98
12/36
Standard Thread Part numberorifice for Orifice
size dia. inches (mm) M6 tapered M8 x 1 tapered G 3/8 G 1/2
0.020 (0.5) 00157933 – – –
0.023 (0.6) 00157934 – – –
0.028 (0.7) 00157931 – – –
16 0.032 (0.8) 00152276 00136843 00159043 –
25 0.039 (1.0) 00149335 00136842 00159033 00139115
32; 40 0.047 (1.2) 00152286 00139101 00159032 00150714
50 0.059 (1.5) 00148823 00133712 00159031 00139117
63 0.071 (1.8) 00157932 00150953 00159030 00159026
80 0.079 (2.0) 00156650 00137299 00159029 00148352
100 0.098 (2.5) 00157929 00137445 00146259 00148353
0.118 (3.0) 00181894 00144761 00149044 00148361
0.138 (3.5) – 00136079 00146258 00159027
0.158 (4.0) – 00802480 00149052 00149939
0.197 (5.0) – – 00152287 00143775
0.236 (6.0) – – 00135774 00147875
0.315 (8.0) – – – 00159028
Plug 00023986 00003443 00006325 00006445
0,02(0,5)
0,024(0,6)
0,028(0,7)
0,032(0,8)
0,039(1)
0,047(1,2)
0,059(1,5)
0,071(1,8)
0,079(2)
0,098(2,5)
0,118(3)
0,158(4)
0,197(5)
0,236(6)
0,315(8)
0,138(3,5)
(0,05) (0,1) (0,2) (0,5)
(1)
(2) (3) (4) (5) (10) (15) (20) (30)(40)(50) (100)
(0,25)(0,35)
(0,5)(0,7)
(1,4)(2)
(3)(4)(5)
(10)
(20)(30)(40)(50)
(100)
(200)
(300)(400)
14,5
3,635,087,2510,2
20,329
43,558
72,5
145
290435580725
1450
2901
43515802
0,01 0,03 0,053 0,132 0,528 0,791,06
1,32 2,643,96
5,287,93
10,5713,21
26,42
Operating curves for the selection of orifices
Part numbers for orifices and plugs
Flow qv in GPM (L/min)
Size Dimensions Part numberin inches (mm) NBR FPM
R-ring 16 0.331 x 0.055 x 0.07 (8.41 x 1.4 x 1.78) 00025407 0002540825 0.386 x 0.059 x 0.07 (9.81 x 1.5 x 1.78) 00017453 0001761032 0.44 x 0.063 x 0.07 (11.18 x 1.6 x 1.78) 00017455 00017611
40, 50 0.504 x 0.095 x 0.103 (12.81 x 2.4 x 2.62) 00017457 0001761763 0.737 x 0.103 x 0.103 (18.72 x 2.62 x 2.62) 00024445 0002444680 1.046 x 0.139 x 0.139 (26.57 x 3.53 x 3.53) 00017466 00017630100 1.36 x 0.139 x 0.139 (34.52 x 3.53 x 3.53) 00017472 00017633
O-ring 125 1.609 x 0.139 (40.87 x 3.53) 00009376 00009505160 2.1 x 0.21 (53.35 x 5.33) 00009264 00009263
Thread Orifice - dia.inches (mm)
M6 taper 0.02 to 0.118(0.5 to 3.0)
M8x1 taper 0.03 to 0.158(0.8 to 4.0)
G 3/8 0.03 to 0.236(0.8 to 6.0)
G 1/2 0.039 to 0.315(1.0 to 8.0)
"G" pipe thread to ISO228/1
1) Possible orifice - diameterin relation to the thread size
Orifices - dia. in inches (mm) 1)
Pre
ssur
e di
ffere
ntia
l ∆p
in P
SI (
bar)
Dimensions of R-rings (O-rings) for ports X, Y, Z1, Z2 (included within the scope of supply)
RA 21 010/06.98
13/36
Size Part number16 25 32
Seal kit for NBR FPM NBR FPM NBR FPM
…D..; ..D../F..WE..; ..WEM..; ..WEC.. 00313758 00313759 00313760 00313761 00313762 00313763
..H.-../F.. 00313951 00313952 00313953 00313954 00313800 00313801
..G..; ..GW..; ..KW.. 00313961 00313962 00313804 00313805 00313808 00313809
..R..; ..RF-.. 00313996 00313997 00313998 00313999
..E../F.. 00313830 00313831 00312829 00312831 00313838 00313839
..EH2-.. 00313857 00313858 00313834 00313835 00313861 00313862
..EW.. 00312199 00312200 00312194 00312195 00312196 00312204
Size Part number40 50 63
Seal kit for NBR FPM NBR FPM NBR FPM
..D../F;
..WE..; ..WE.8..; ..WE.9.. 00313863 00313864 00313863 00313864 00313865 00313866
..H.-../F.. 00313867 00313868 00313869 00313870 00313871 00313872
..G..; ..GW..; ..KW.. 00313873 00313874 00313875 00313876 00313877 00313878
..R..; ..R2-.. 00310836 00310837 00310836 00310837 00310840 00310841
..E../F.. 00312005 00312006 00312007 00312008 00312597
..EH2-.. 00312163 00312164 00314422 00312185
..EW.. 00311547 00311548 00312095 00313150 00314423
Tight.Size Cover Qty. UNC Metric torque
lb-ft (Nm)
16 WEA, WEB, GWA, 4 5/16" – 1-3/4" M8 x 45 25 (32)GWB, SEA, GSA, US00 833 372 US00 835 099KWA, KWB
EH2 4 – M8 x 80 25 (32)
EWA, EWB 4 M8 x 85 25 (32)
** 4 5/16" – 1-1/2" M8 x 40 25 (32)US00 833 371
25 EH2, EWA, EWB 4 – M12 x 90 80 (110)
** 4 1/2" – 2" M12 x 50 80 (110)US00 833 846
32 EH2, EWA, EWB 4 – M16 x 110 200 (270)
** 4 5/8" – 2-1/4" M16 x 60 200 (270)US00 835 180
40 E, EH2, EWA, EWB 4 – M20 x 140 385 (520)
H1, H2 4 3/4" – 3-1/2" M20 x 90 385 (520)
** 4 3/;4" – 2-3/4" M20 x 70 385 (520)US00 835 240
50 H2, H4 4 7/8 – 4-3/4" M20 x 120 385 (520)** All other standard coversNote: SAE grade 8 or better, metric bolts greater than DIN 912-10.9
Mounting Bolts - S.H.C.S. to DIN 912-10.9
Seal kits for control covers model LFA .../...
Size Part number80 100 125 160
Seal kit for NBR FPM NBR FPM NBR FPM NBR FPM
..D../F; 00312785 00312814 00312786 00312815 00314074 00310850 00310868 00310869
..WE.. 00314824 00314825 00314836 00314837
..H1-..; ..H2-.. 00314816 00314817 00314828 00313829 00314840 00314841 00314498 00314499
..H3-..; ..H4-.. 00314818 00314819 00314830 00314831
..G..; ..GW..; ..KW..-.. 00314826 00314827 00314838 00314839
..R..; ..R2-.. 00314822 00314823 00314834 00314835
Tight.Size Cover Qty. UNC Metric torque
lb-ft (Nm)
50 E 4 – M20 x 140 385 (520)
EH2, EWA, EWB 4 – M20 x 160 385 (520)
** 4 7/8" – 3-1/4" M20 x 80 385 (520)US00 835 692
63 H2, H4 4 1-1/4" – 5-1/2" M30 x 140 1300US00 835 695 (1800)
E 4 – M30 x 180 1300 (1800)
EH2, EWA, EWB 4 – M30 x 200 1300 (1800)
** 4 1-1/4" – 4" M30 x 100 1300 (1800)US00 833 693
80 H2, H4 8 – M24 x 120 665 (900)
** 8 – M24 x 100 665 (900)
100 D, WEA, WEB 8 – M30 x 100 1300 (1800)
** 8 – M30 x 120 1300 (1800)
125 D, H2 8 – M36 x 160 2290 (3100)
160 D, H2 12 – M42 x 220 3690(5000)
RA 21 010/06.98
14/36
0.158 (4)
D2/
T1
H2H
1H
3
X**
D3
H4
D1
X
4
3
0.158 (4)
D1/
T1
H2
H1
H3
X
X**
D2
X
L2
L10.
079
(2)
H4
1
4 2
Size 16 25 32 40 50 63
D1* SAE-4; SAE-6; SAE-6; SAE-8; SAE-8; SAE-12;7/16–20 9/16–18 9/16–18 3/4–16 3/4–16 1-1/6–12(G 1/8) (G 1/4) (G 1/4) (G 1/2) (G 1/2) (G 3/4)
D2 2) M6 M6 M6 M8x1 M8x1 G 3/8
H1 1.06 (27) 1.18 (30) 1.38 (35) 2.36 (60) 2.68 (68) 3.23 (82)
H2 0.47 (12) 0.63 (16) 0.63 (16) 1.18 (30) 1.26 (32) 1.58 (40)
H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)
H4 0.32 (8) 0.47 (12) 0.63 (16) – – –
L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)
L2 1.28 (32.5) 1.67 (42.5) 1.97 (50) 2.84 (72) 3.15 (80) 3.54 (90)
T1 0.32 (8) 0.47 (12) 0.47 (12) 0.55 (14) 0.55 (14) 0.63 (16)
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Name plate for sizes 80, 100, 125, 1604 Port X optionally as a threaded connection
Nominal size16 25 32 40 50 63 80 100 125 160
xx x x x x x x x x x F X**
LFA D –
Control cover with or without remote control connection model ..D..; ..D../F.. : dimensions ininches (millimeters)
Sizes 16 to 63
1 2 3 41) 9 14 17
Orifice in port +Ø in 0.004 in
(1/10 mm)
Remotecontrol
port
Orifice possible, if required state details1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63, 80, 100)2X = series 2X (sizes 125, 160)
LFA.16D-7X/... LFA..D../F.. LFA..D../FX**
XB
A
X
XB
A
X**X
XB
A
Sizes 80 to 160
Size 80 100 125 160
D1 9.84 (250) 11.8 (300) 14.96 (380) 18.9 (480)
D2* SAE-12; SAE-16; SAE-20; SAE-20;1-1/16–12 1-5/16–12 1-5/8–12 1-5/8–12
(G 3/4) (G 1) (G 1 1/4) (G 1 1/4)
D32) G 3/8 G 1/2 G 1 G 1
H1 2.76 (70) 2.95 (75) 4.13 (105) 5.79 (147)
H2 1.38 (35) 1.58 (40) 1.97 (50) 2.76 (70)
H3 1.77 (45) 2.07 (52.5) 2.4 (61) 2.91 (74)
H4 – 0.95 (24) 1.22 (31) 1.65 (42)
T1 0.63 (16) 0.71 (18) 0.79 (20) 0.79 (20)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
2) For orifice ordering details see page 12.* SAE dimensions for LFA…/.../12 covers.
2) For orifice ordering details see page 12.* SAE dimensions for LFA…/.../12 covers.
RA 21 010/06.98
15/36
Nominal size16 25 32 40 50 63
x x x x F X**x x x x x x F X**x x x x F X**x x x x x x F X**
LFA – F
Sizes 16 to 63
1 2 3 41) 9 14 17
Orifice possible, if required, state details1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)
Adjust-ment
Remotecontrol
portH1
LFA.H.-../F
LFA.H.-../FX**
H4H3H2
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Port X optionally as a threaded
connection4 Hexagon 21 A/F5 Internal hexagon 19 A/F6 Hexagon 6 A/F7 Hexagon 5 A/F (lock nut)8 Scale9 Adjustment "H1" (sizes 16 to 40)10 Adjustment "H2" (sizes 16 and 25)11 Adjustment "H2" (sizes 32 to 63)12 Adjustment "H3" (sizes 16 to 40)13 Adjustment "H4" (sizes 16 to 40)14 Adjustment "H4" (sizes 50 and 63)
X
XB
A
X**X
XB
A
Orifice in port +dia. in 0.004 in
(1/10 mm)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Control cover with stroke limiter, with remote control connection model ..H.. : dimensions ininches (millimeters)
2) For orifice ordering details see page 12.* SAE dimensions for LFA…/.../12 covers.
3) Only valid for adjustments “H3” and “H4”.A/F = Across Flats
Size 16 25 32 40 50 63
D1* SAE-4; SAE-6; SAE-6; SAE-8; SAE-8; SAE-12;7/16–20 9/16–18 9/16–18 3/4–16 3/4–16 1-1/6–12(G 1/8) (G 1/4) (G 1/4) (G 1/2) (G 1/2) (G 3/4)
D2 2) M6 M6 M6 M8x1 M8x1 G 3/8ØD3 2.05 (52) 3.15 (80) 3.15 (80) 4.92 (125) – –H1 1.38 (35) 1.58 (40) 2.95 (75) 2.36 (60)3) 3.15 (80) 2.36 (60)3) 2.68 (68) 3.23 (82)H2 0.47 (12) 0.63 (16) 0.63 (16) 1.18 (30) 0.87 (22)3) 1.26 (32) 1.58 (40)H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)
H4 max 3.54 (90) 3.74 (95) 4.72 (120) 5.35 (136) – –H5 max 2.99 (76) 3.15 (80) 3.94 (100) 4.53 (115) 5.31 (135) 6.1 (155)H6 max 5.51 (140) 5.71 (145) 7.09 (180) 7.68 (195) – –H7 max 4.53 (115) 4.72 (120) 6.1 (155) 6.69 (170) 7.4 (188) 8.07 (205)
L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L2 1.28 (32.5) 1.67 (42.5) 1.97 (50) 2.5 (62.5)3) 2.84 (72) 3.15 (80) 3.54 (90)T1 0.32 (8) 0.47 (12) 0.47 (12) 0.55 (14) 0.55 (14) 0.63 (16)
1A/F – – 0.39 (10) 0.47 (12) 0.67 (17) 0.75 (19)2A/F – – 1.06 (27) 1.42 (36) 1.81 (46) 2.17 (55)
1 32
X
6 45
0.158 (4)
D1/
T1
H2
H5
XX**
D2
L2
L10.
079
(2)
H4
H1 Ø 1.5 (38) H
5
1A/F
2A/F
H6
0.71
(18
)
H3
H7
Ø 1.81 (46)
H7 2.
48 (
63)
Ø 2.76 (70)
0.039 (1)
Ø 1.58 (40)1.
1 (2
8)
Ø D3
3 2
1
85
14
7
13
9 4 4 106 11 12
Adjustment "H1"
Adjustment "H4"
Adjustment "H2"
Adjustment "H3"
RA 21 010/06.98
16/36
X
X
012 9 8
0.158 (4)
D2/
T1
H2H
1H
3
X**D3
H5
D1
H4
max
. H7
2A/F
1A/F
H5
H6
max
. H7
495
6
1
2
7 83
Nominal size80 100 125 160
x x x x H2 F X**x x H4 F X**
LFA – F1 2 3 41) 9 14 17
Orifice in port +dia. in 0.004 in
(1/10 mm)
Remotecontrol port
Orifice possible, if required, state details1) 6X = series 6X (sizes 80, 100)
2X = series 2X (sizes 125, 160)
Adjust-ment
LFA.H.-../F.. LFA.H.-../FX**
X
XB
A
X**X
XB
A
Adjustment "H2" Adjustment "H4"
Size 80 100 125 160D1 9.84 (250) 11.8 (300) 14.96 (380) 18.9 (480)D2* SAE-12; SAE-16; SAE-20; SAE-20;
1-1/16–12 1-5/16–12 1-5/8–12 1-5/8–12(G 3/4) (G 1) (G1 1/4) (G1 1/4)
D3 2) G 3/8 G 1/2 G 1 G 1H1 4.49 (114) 5.2 (132) 6.69 (170) 8.86 (225)H2 1.38 (35)0.95 (24)3) 1.38 (35) 1.97 (50) 2.76 (70)H3 1.77 (45) 2.07 (52.5) 2.4 (61) 2.91 (74)H4 2.99 (76) 3.48 (88.5) 3.94 (100) 5.79 (147)H5 5.39 (137) 6.18 (157) 7.68 (195) 13.4 (340)H6 9.02 (229) 9.72 (247) – –H7 1.18 (30) 1.52 (38) 1.89 (48) –T1 0.63 (16) 0.71 (18) 0.79 (20) 0.79 (20)
1A/F 2.95 (75) 2.95 (75) 3.74 (95) –2A/F4) 0.95 (24) 1.06 (27) 1.06 (27) –
Control cover with stroke limiter, with remote control connection model ..H.. : dimensions ininches (millimeters)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Sizes 80 to 160
1 Name plate2 Port X optionally as a threaded
connection3 Internal hexagon 32 A/F4 Internal hexagon 14 A/F
5 Internal hexagon 5 A/F6 Hexagon 8 A/F (lock screw)7 Adjustment "H2" (sizes 80 to 125)8 Adjustment "H2" (size 160)9 Adjustment "H4" (sizes 80 and 100)
2) For orifice ordering details see page 12.* SAE dimensions for LFA…/.../12 covers.
3) Only valid for adjustment “H4”.A/F = Across Flats
RA 21 010/06.98
17/36
Size Orifice in portX Z1
16 dia. 0.047 (1.2) dia. 0.047 (1.2)
25 dia. 0.059 (1.5) dia. 0.059 (1.5)
32 dia. 0.079 (2.0) dia. 0.079 (2.0)
40 X0.472 (12) Z0.472 (12)
50 X0.591 (15) Z0.591 (15)
63 X0.709 (18) Z0.709 (18)
Z1
Z2
G 1/2;0.53 (14)
D2
D2
G 1/2;0.53 (14)
L4
H2
H1
H3
X
D1
X
L2
L10.
079
(2)
Z1
L3L5
0.15
8 (4
)0.
158
(4)
H5
H4
54
2
3
LFA G –
Sizes 16 to 63
1 2 3 41) 14 16 17
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Ports Z1 and Z2 optionally as a threaded connection
for sizes 50 and 634 Shuttle valve5 D2 for sizes 16 to 40
Size 16 25 32 40 50 63D1 dia. 0.047 dia. 0.059 dia. 0.079 M6 M8x1 M8x1
(dia. 1.2) (dia. 1.5) (dia. 2.0)D2 dia. 0.047 dia. 0.059 dia. 0.079 M6 M8x1 M8x1
(dia. 1.2) (dia. 1.5) (dia. 2.0)H1 1.38 1.18 1.38 2.36 2.68 3.23
(35) (30) (35) (60) (68) (82)H2 0.67 0.67 0.85 1.18 1.26 1.58
(17) (17) (21.5) (30) (32) (40)H3 0.59 0.95 1.1 1.26 1.34 1.97
(15) (24) (28) (32) (34) (50)H4 – 0.47 0.63 – – –
– (12) (16) – – –H5 – – – – 1.26 1.58
– – – – (32) (40)L1 2.56 3.35 3.94 4.92 5.51 7.09
(65) (85) (100) (125) (140) (180)L2 1.44 1.79 1.97 2.46 2.91 3.54
(36.5) (45.5) (50) (62.5) (74) (90)L3 – – – – 2.84 3.11
– – – – (72) (79)L4 – – – – 2.84 3.54
– – – – (72) (90)L5 0.098 0.079 – – 0.236 0.079
(2.5) (2) – – (6) (2)
6
Control cover with built-in shuttle valve model ..G.. : dimensions in inches (millimeters)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
does not appearin the model
code1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)
Drilled orifice – dia. in inches (mm)
Standard orifice – dia. in 0.004 inches (1/10 mm)
XB
A
Z1Z.. X..
Z2
Z1 Z2
XB
A
Z1Z12 X12
Z2XB
A
Z1 Z2
LFA..G-7X/...Sizes 16 to 32
LFA..G-6X/...Size 40
LFA..G-6X/...Sizes 50 and 63
RA 21 010/06.98
18/36
XB
A
Z1Z20 X20
Z2
Z1 Z2
M
F**
LFA G – 6X
Control cover with built-in shuttle valve model ..G.. : dimensions in inches (millimeters)
Sizes 80 and 100
1 2 3 4 14 15 16 17
Orifice in portSize + dia. in 0.004 in (1/10 mm)
X F Z180 X0.79 (20) F** Z0.79 (20)
100 X0.79 (20) F** Z0.79 (20)
1 Name plate2 Test point3 Port Z1 optionally as a threaded connection4 Port Z2 optionally as a threaded connection5 Shuttle valve
LFA..G-6X/...
Size 80 100D1 9.84 (250) 11.8 (300)H1 3.15 (80) 2.95 (75)H2 1.77 (45) 1.69 (43)H3 1.77 (45) 2.07 (52.5)H4 0.158 (4) 0.925 (23.5)L1 2.87 (73) 3.8 (96.5)
Standard orifice – does not appear in the model code
Orifice possible, if required state details
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
X M
Z1
Z2
X
H1
H3
M8 x 1
H4
D1
L1
G 1/4; 12
H2
M8 x 1
Z1
Z2
G 1/2; 0.551 (14)
Ø 1.34 (34); 0.118 (3)
H2
0.11
8 (3
)
M8 x 1
Ø 1.34 (34); 0.118 (3)
G 1/2; 0.551 (14)
0.11
8 (3
)3
2
4 1
5
RA 21 010/06.98
19/36
Size 25 32 40 50 63D13) M6 M6 M8x1 M8x1 M8x1D2 3) M6 M6 M8x1 M8x1 M8x1H1 1.58 1.97 2.36 2.68 3.23
(40) (50) (60) (68) (82)H2 0.79 1.02 1.3 1.26 1.58
(20) (26) (33) (32) (40)H3 0.79 1.02 1.26 1.34 1.97
(20) (26) (32) (34) (50)L1 3.35 3.94 4.92 5.51 7.09
(85) (100) (125) (140) (180)L2 R 0.079 0.039 1.06 0.95 0.73
(2) (1) (27) (24) (18.5)L2 RF; R2 0.73 0.69 1.06 0.95 0.73
(18.5) (17.5) (27) (24) (18.5
Sizes 25 to 63
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Port Z1 optionally as a threaded connection for size 634 Port Y optionally as a threaded connection for size 635 D1 for size 16 to 506 D1 for size 63
3) For orifice ordering details see page 11.4) Pressure in port Y max. 72.5 PSI (5 bar)
Area relationship =A Z1 3A X 1
RFLFA..R2-../..Sizes 25 to 50
LFA..R-../..Sizes 25 to 50
LFA63R2-6X/..Size 63
LFA63R-6X/..Size 63
4) 4) 4) 4)XB
A
Z1
Z12
Y
F**X..X
B
A
Z1
Z12
YF**
Z1
Y
X10X
B
A
Z1
Z12
YF**X..
XB
A
Z1
Z12
YF**
Z1
Y
X10
Standard orifice – does not appear in the model code
Orifice possible, if required state details1) 7X = series 7X (sizes 25, 32)
6X = series 6X (sizes 40, 50, 63)2) Directional poppet valve with spring return
Control cover wih integral poppet valve models ..R..; ..RF..; ..R2.. : dimensions in inches(millimeters)
LFA –1 2 3 41) 14 15 16 17
Orifice in portSize Model + dia in 0.004 (1/10 mm)
X F Z125 R X0.39 (10) F** Z0.47 (12)32 R X0.47 (12) F** Z0.47 (12)40 R X0.59 (15) F** Z0.47 (12)50 R X0.59 (15) F** Z0.47 (12)63 R X0.71 (18) F** Z0.47 (12)25 RF2) X0.39 (10) F** Z0.47 (12)32 RF2) X0.47 (12) F** Z0.47 (12)40 R22) X0.59 (15) F** Z0.47 (12)50 R22) X0.59 (15) F** Z0.47 (12)63 R22) X0.71 (18) F** Z0.47 (12)
3
4
1
2
Z1
H2
H1
H3
X
XL10.
079
(2)
Z1
0.15
8 (4
)L2
F
D2
1.58
(40
)
Y
G 1/4; 0.47 (12)
2.99
(76
)
G 1/2; 0.55 (14)
0.158 (4)
D1
D1 6
5
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
20/36
H1
H3
D1
X Y
X Y Y
Z1
M8 x 13)
0.15
8 (4
)
H2
L2
0.23
6 (6
)
L1
G 1/4; 0.47 (12)
M8x13)
D2
2
13
F**
G 1/4; 0.47 (12)
1 Name plate2 Port Z1 optionally as a threaded connection3 Port X optionally as a threaded connection
3) For orifice ordering details see page 11.4) Pressure in port Y max. 72.5 PSI (5 bar)
Size 80 100D1 9.84 (250) 11.8 (300)D2 G1/4; 0.47 (12) G1/2; 0.55 (14)H1 3.15 (80) 3.54 (90)H2 1.42 (36) 1.77 (45)H3 1.77 (45) 2.07 (52.5)L1 2.05 (52) 2.91 (74)L2 0.83 (21) 0.67 (17)L3 0.236 (6) 0.197 (5)
Area relationship =A Z1 3A X 1
Control cover wih integral poppet valve models ..R.., ..R2.. : dimensions in inches (millimeters)
Standard orifice – does not appear in the model code
Orifice possible, if required state details2) Directional poppet valve with spring return
Sizes 80 and 100
LFA – 6X1 2 3 4 14 15 16 17
Orifice in portSize Model + dia in 0.004 (1/10) mm
X F Z180 R X0.79 (20) F** Z0.47 (12)
100 R X0.98 (25) F** Z0.47 (12)80 R22) X0.79 (20) F** Z0.47 (12)
100 R22) X0.98 (25) F** Z0.47 (12)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Y4)XB
A
Z1
Z12
F**
Z1
Y
X..X
B
A
Z1
Z12
Y4)F**
Z1
Y
X..
LFA..R2-6X/..Sizes 80 and 100
LFA..R-6X/..Sizes 80 and 100
RA 21 010/06.98
21/36
4WE 6 D../… 4WE 6 D../…
XB
A
Y
A B
P TP** T** A**
XB
A
Y
A B
P TP** T** B**
XY
XB
A
Y
A B
P TP** T** A**
XY
LFA..WEA-6X/…Sizes 40 to 63
LFA..WEB-6X/…Sizes 40 to 63
LFA..WEA-7X/…Sizes 16 to 32
XB
A
Y
A B
P TP** T** B**
LFA..WEB-7X/…Sizes 16 to 32
Directional poppet valveUM-3SEW 6 ../…C
A
H2
H1
H3
XL10.
079
(2)
Y
Y
L4
X
B A
A
P
T
1.28
(32
.5)
L3
L5
M6
L20.158 (4)
M6
L6 1.6 (40.5)
B
1
2
1.22
(31)
3
4
0.158 (4)
SA
E-8
; 1/4
–16
[G 1
/2; 0
.55
(14)
]
SA
E-8
; 1/4
–16
[G 1
/2; 0
.55
(14)
] Directional valve4WE 6 D../…M-3SEDG...
1 Name plate for sizes16, 25, 32
2 Name plate for sizes40, 50, 63
3 Ports X and Yoptionally as athreaded connectionfor sizes 40, 50, 63
4 Valve mountingbolts are includedwithin the scope ofthe control coversupply
A
P T
M-3SED 6 U../350…
M-3SEW 6 U../420…
M-3SED 6 C../350…
M-3SEW 6 C../420…
A
P Ta
A
P T
Orifice in portNominal size Model (dia. in 1/10 mm)
16 25 32 40 50 63 A B P T
x x x x x x WEA A** P** T**x x x x x x WEB B** P** T**
LFA –
1 2 3 41) 10 11 12 13 17
Sizes 16 to 63
Size 16 25 32 40 50 63H1 1.58 1.58 1.97 2.36 2.68 3.22
(40) (40) (50) (60) (68) (82)H2 – – – 1.18 1.26 1.58
– – – (30) (32) (40)H3 0.59 0.95 1.1 1.26 1.34 1.97
(15) (24) (28) (32) (34) (50)L1 2.59 3.35 3.94 4.92 5.51 7.09
(65) (85) (100) (125) (140) (180)L2 3.15 3.35 3.94 4.92 5.51 7.09
(80) (85) (100) (125) (140) (180)L3 – – – 2.84 3.15 3.98
– – – (72) (80) (101)L4 – – – 2.09 2.36 3.11
– – – (53) (60) (79)L5 0.67 1.06 1.36 1.85 2.15 2.93
(17) (27) (34.5) (47) (54.5) (74.5)L6 0.28 0.93 1.22 1.71 2.01 2.8
(7) (23.5) (31) (43.5) (51) (71)
For orifice ordering details see page 12.
Orifice possible, if required state details1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)
Control cover for mounting a directional spool or poppet valve model ..WE .. : dimensions in inches (millimeters)AB
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
22/36
For orifice ordering details see page 12.
1 Name plate3 Ports X and Y optionally as a threaded connection4 Valve mounting bolts are included within the
scope of the control cover supply5 Plug for model .. WEB..6 Plug for model .. WEA..
Size 80 100D1 9.84 (250) 11.8 (300)H1 3.15 (80) 3.94 (100)H2 1.18 (30) 0.95 (24)H3 1.77 (45) 2.07 (52.5)H4 1.77 (45) 2.17 (55)L3 0.39 (10) 0.51 (13)L4 1.18 (30) 1.1 (28)
Control cover for mounting a directional spool or poppet valve model ..WE .. : dimensions in inches (millimeters)AB
Orifice possible, if required state details
Orifice in portNominal size Model (dia. in 0.004 (1/10 mm)
80 100 A B P Tx x WEA A** P** T**x x WEB B** P** T**
LFA – 6X1 2 3 4 10 11 12 13 17
A
P Ta
A
P Ta
M-3SED 10 C../350…
M-3SEW10 C../420…
A
P T
M-3SED 10 U../350…
M-3SEW10 U../420…
LFA..WEA-6X/…Sizes 80 and 100
LFA..WEB-6X/…Sizes 80 and 100
XB
A
Y
A B
P TP** T** A**
XY
a
XB
A
Y
A B
P TP** T** B**
XY
a
4WE 10 D../…
A
H2H
1
D1
X
X YB T
PA
0.079 (2)
H4
Ø 3
4; 0
.158
(4)
M8 x 1
L3
1.063 (27)
2.13 (54)
1.81
(46
)
L4
M8 x 1
H3
L3
5
6
3
4
1
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
Ø 3
4; 0
.158
(4)
0.079 (2)
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
Directional poppet valveUM-3SEW 10 ../…C
Directional valve4WE 10 D../…M-3SED10....
Sizes 80 and 100
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
23/36
Sizes 16 to 63
1 Name plate for models 16, 25, 322 Name plate for models 40, 50, 633 Ports X, Y, Z1 and Z2 optionally as a threaded connection
for sizes 40, 50, 634 Valve mounting bolts are within the scope of the control
cover supply5 Plug M6 for ..WEMB... or ..WEB8-...6 Plug M6 for ..WEMA... or ..WEA8-...
For orifice ordering details see page 12.
4WE 6 D../… 4WE 6 D../…
XB
A
Y
A B
P TP** T**
F**Z1 Z2
Z1
X Z2
Y
LFA..WEB8-6X/…Sizes 40 to 63
XB
A
Y
A B
P TP** T**
F**Z2 Z1
LFA..WEMA-7X/…Sizes 16 to 32
XB
A
Y
A B
P TP** T**
F**Z1 Z2
LFA..WEMB-7X/…Sizes 16 to 32
XB
A
Y
A B
P TP** T**
F**Z2 Z1
Z2
X Z1
Y
LFA..WEA8-6X/…Sizes 40 to 63
Directional poppet valveUM-3SEW 6 ../…C
Size 16 25 32 40 50 63H1 2.56 (65) 1.58 (40) 1.97 (50) 2.36 (60) 2.68 (68) 3.23 (82)H2 – – – 1.18 (30) 1.26 (32) 1.58 (40)H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)H4 – – – 1.18 (30) 1.26 (32) 2.36 (60)L1 2.56 (65) 3.35 (85) 3.94 (100) 4.9 (125) 5.51 (140) 7.1 (180)L2 3.15 (80) 3.35 (85) 3.94 (100) 4.9 (125) 5.51 (140) 7.1 (180)L3 – – – 2.09 (53) 2.36 (60) 3.11 (79)L4 0.67 (17) 1.06 (27) 1.36 (34.5) 1.85 (47) 2.15 (54.5) 74.5L5 0.28 (7) 0.93 (23.5) 1.22 (31) 1.7 (43.5) 2.01 (51) 71L6 – – – 2.84 (72) 3.15 (80) 101
A
P Ta
A
P T
M-3SED 6 C../350…
M-3SEW 6 C../420…
A
P T
M-3SED 6 U../350…M-3SEW 6 U../420…
Orifice possible, if required state details
1) 7X = series 7X (sizes 16, 25, 32)6X = series 6X (sizes 40, 50, 63)
A
H2
H1
H3
X
L10.
079
(2)
Y
Y
L3
X
B A
A
P
T
1.28
(32
.5)
L6
L4
M6
L2
0.158 (4)
0.158 (4)
L5
1.6 (40.5)
H4
H2
B
Z1
0.07
9 (4
)
L6
0.15
8 (4
)
1.22
(31)
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
L3
1
2
5
4
6Directional valve4WE 6 D../...M-3SED....
3
LFA –1 2 3 41) 12 13 15 17
Orifice in portNominal size Model (dia. in 0.004 (1/10 mm)
16 25 32 40 50 63 P T Fx x x WEMA P** T** F**x x x WEMB P** T** F**
x x x WEA8 P** T** F**x x x WEB8 P** T** F**
Control cover for mounting a directional spool or poppet valve models ..WEM ...; WE 8... : dim. in inches (millimeters)AB
AB
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
24/36
Sizes 80 and 100
For orifice ordering details see page 12.
LFA.WEA8-6X/…Sizes 80, 100
LFA.WEB8-6X/…Sizes 80, 100
XB
A
Y
Aa
B
P TP** T** A**
XY
XB
A
Y
Aa
B
P TP** T** B**
XY
4WE 10 D../…
Directional poppet valveUM-3SEW 10 ../…C
1 Name plate3 Ports X, Y, Z1 and Z2 optionally as a
threaded connection G 1/2; 144 Valve mounting bolts are included within
the scope of the control cover supply5 Plug for ...WEB8-...6 Plug for ...WEA8-...
Size 80 100D1 9.84 (250) 11.8 (300)H1 3.15 (80) 3.94 (100)H2 1.65 (42) 2.17 (55)H3 1.77 (45) 2.07 (52.5)H4 1.02 (26) 1.38 (35)L3 0.39 (10) 0.51 (13)L4 0.39 (10) 0.37 (9.5)L5 1.18 (30) 1.06 (27)
A
0.079 (2)
H2H
1
D1
X
X YB T
PA
Ø 1
.34
(34)
; 0.1
58 (4
)
H2
M8 x 1
L3
1.063 (27)
2.13 (54)
1.81
(46
)L5
M8 x 1
H3
L3
5
6
3
Z1
Z2
H4
L4L4
4
1
Ø 1
.34
(34)
; 0.1
58 (4
)
0.079 (2)
Directional valve4WE 10 D../…M-3SED10...
A
P Ta
A
P Ta
M-3SED 10 C../350…
M-3SEW 10 C../420…
A
P T
M-3SED 10 U../350…
M-3SEW 10 U../420…
Nominal Orifice in portsize Model (dia. in 0.004 in (1/10 mm)
80 100 P T Fx x WEA8 P** T** F**x x WEB8 P** T** F**
LFA – 6X1 2 3 4 12 13 15 17
Oifice possible, if required state details
Control cover for mounting a directional spool or poppet valve models WE 8... : dimensions in inches (millimeters)AB
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
25/36
Orifice in portNominal size Model (dia. in 0.004 in (1/10 mm)
16 25 32 40 50 63 A B P T
x x x WECA A** B** P** T**x x x WEA9 A** B** P** T**
LFA –1 2 3 41) 10 11 12 13 17
Sizes 16 to 63
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Ports X, Y and Z1 optionally as a threaded connection for
sizes 40, 50, 634 Valve mounting bolts are included within the scope of
the control cover supply
XB
A
Y
A B
P TP** T**A** B**
Z1 XB
A
Y
A B
P TP** T**A** B**
Z1
Z1X
Y
3WE 6 A../…
LFA..WECA-7X/…Sizes 25 to 32
LFA..WEA9-6X/…Sizes 40 to 63
Control cover for mounting a directional spool valve models ..WECA...; WEA9... : dim. in inches (millimeters)
LFA16WECA-7X/…Size 16
XB
A
Y
A B
P TP** T**A** B**
Z1 Z2
2
3
1 3
A
H2
H1
H3
XL10.
079
(2)
Y
Y
L3
X
B A
AP
T1.28
(32
.5)
L6
L4
M6
L2
0.158 (4)
M6
L5 1.6 (40.5)
B
Z1
L7
0.15
8 (4
)
H4
H2
1.22
(31)
0.158 (4)
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
Directional spool valve
3WE 6 A../…
4NG 16 25 32 40 50 63H1 1.58 1.58 1.97 2.36 2.68 3.23
(40) (40) (50) (60) (68) (82)H2 – – – 1.18 1.26 1.58
– – – (30) (32) (40)H3 0.59 0.95 1.1 1.26 1.34 1.97
(15) (24) (28) (32) (34) (50)H4 – – – 1.18 1.26 2.36
– – – (30) (32) (60)L1 2.56 3.35 3.94 4.92 5.51 7.09
(65) (85) (100) (125) (140) (180)L2 3.15 3.35 3.94 4.92 5.51 7.09
(80) (85) (100) (125) (140) (180)L3 – – – 2.09 2.36 3.11
– – – (53) (60) (79)L4 0.67 1.06 1.36 1.85 2.15 2.93
(17) (27) (34.5) (47) (54.5) (74.5)L5 0.28 0.93 1.22 1.71 2.01 2.8
(7) (23.5) (31) (43.5) (51) (71)L6 – – – 2.46 2.76 3.54
– – – (62.5) (70) (90)L7 – – – 2.84 3.15 3.98
– – – (72) (80) (101)
For orifice ordering details see page 12.
Orifice possible. if required state details1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
26/36
Size 80 100
D1 9.84 (250) 11.8 (300)H1 3.15 (80) 3.94 (100)H2 1.18 (30) 1.58 (40)H3 1.77 (45) 2.07 (52.5)H4 1.18 (30) 2.76 (70)L2 0 0.24 (6)L3 0.24 (6) 0.24 (6)L4 0.24 (6) 0.24 (6)L5 0.91 (23) 0.75 (19)
Control cover for mounting a directional spool valve model ..WEA9.. : dimensions in inches (millimeters)
Sizes 80 and 100
For orifice ordering details see page 12.
XB
A
Y
A B
P TP** T**A** B**
Z1
Z1X
Y
3WE 10 A../…
LFA..WEA9-6X/…Sizes 80, 100
Directional spool valve
3WE 10 A…
1 Name plate3 Ports X, Y and Z1 optionally as a threaded
connection SAE-8; 3/4-16 [G 1/2; 0.55 (14)]4 Valve mounting bolts are included within
the scope of the control cover supply
A
H2
H1
D1
X
X YB T
PA
Ø 1
.34
(34)
; 0.1
58 (
4)
0.079 (2)
H2
M8 x 1
L2
1.06 (27)
2.13 (54)
1.81
(46
)
L5
M8 x 1
H3
L3
1
3
Z1
H4
L4
4
Ø 1
.34
(34)
; 0.1
58 (
4)
0.079 (2)
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
Orifice in portModel (dia in 0.004 (1/10 mm)
80 100 A B P T
x x WEA9 A** B** P** T**
LFA – 6X1 2 3 4 10 11 12 13 17
Nominalsize
Orifice possible, if required state details
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
27/36
Directional poppet valveUM-3SEW 6 ../…C
A
H4
H1
H3
XL10.
079
(2)
Y
Y
L4
X
B A
AP
T1,28
(32
.5)
L3
L71.
22 (3
1)
M6
L2
0.158 (4)
L6 1,6 (40.5)
B
Z1
L5
0.15
8 (4
)
H2
0.158 (4)
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
7
6
2
1
5
3
3
4
Directional valve4WE 6 D../…M-3SED6....
Control cover for mounting a directional spool or poppet valve model ..GW .. : dim. in inches (mm)
Sizes 16 to 63
AB
For orifice ordering details see page 12.
4WE 6 D../…4WE 6 D../…
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40, 50, 633 Ports Y and Z1 optionally as a threaded connection for sizes
40, 50, 634 Valve mounting bolts are included within the scope of the
control cover supply5 Plug M6 for ..GWB..6 Plug M6 for ..GWA..7 Shuttle valve
1) 7X = series 7X (sizes 16, 25, 32)6X = series 6X (sizes 40, 50, 63)
Orifice possible, if required state details
XB
A
Y
Aa
B
P TP** T** A**
Z1 XB
A
Y
Aa
B
P TP** T** B**
Z1Z1
Y
XB
A
Y
Aa
B
P TP** T** A**
Z1Z1
Y
XB
A
Y
Aa
B
P TP** T** B**
Z1
LFA..GWB-6X/…Sizes 40 to 63
LFA..GWA-7X/…Sizes 16 to 32
LFA..GWB-7X/...Sizes 16 to 32
LFA..GWA-6X/…sizes 40 to 63
A
P Ta
A
P T
M-3SED 6 C../350…
M-3SEW 6 C../420…
A
P T
M-3SED 6 U../350…M-3SEW 6 U../420…
Orifice in portNominal size Model (dia. in 0.004 in (1/10 mm)
16 25 32 40 50 63 A B P T
x x x x x x GWA A** P** T**x x x x x x GWB B** P** T**
LFA –1 2 3 41) 10 11 12 13 17
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Size 16 25 32 40 50 63H1 1.58 (40) 1.58 (40) 1.97 (50) 2.36 (60) 2.68 (68) 3.23 (82)H2 – – – 1.18 (30) 1.26 (32) 1.58 (40)H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)H4 0.67 (17) 0.67 (17) 0.85 (21.5) 1.18 (30) 1.26 (32) 1.65 (42)L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L2 3.15 (80) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L3 1.44 (36.5) 1.79 (45.5) 1.97 (50) 2.46 (62.5) 2.84 (72) 3.54 (90)L4 – – – 2.09 (53) 2.36 (60) 3.11 (79)L5 – – – 2.46 (62.5) 2.76 (70) 3.54 (90)L6 0.28 (7) 0.93 (23.5) 1.22 (31) 1.71 (43.5) 2.01 (51) 2.8 (71)L7 0.67 (17) 1.06 (27) 1.36 (34.5) 1.85 (47) 2.15 (54.5) 2.93 (74.5)
RA 21 010/06.98
28/36
Control cover for mounting a directional spool or poppet valve model ..GW .. : dim. in inches (mm)
Sizes 80 and 100
AB
1 Name plate3 Ports X and Y optionally as a threaded connection4 Valve mounting bolts are included within the scope
of the control cover supply5 Plug for model .. GWB..6 Pug for model .. GWA..7 Shuttle valve8 Test point
XB
A
Y
Aa
B
P TP** T** A**
Z1
M YX
XB
A
Y
Aa
B
P TP** T** B**
Z1
M YX
LFA..GWA-6X/…Sizes 80 and 100
LFA..GWB-6X/…Sizes 80 and 100
4WE 10 D../…
Directional poppet valveCM-3SEW 10 ../…U
For orifice ordering details see page 12.
Size 80 100D1 9.84 (250) 11.8 (300)H1 3.15 (80) 3.94 (100)H2 1.02 (26) 1.58 (40)H3 1.77 (45) 2.07 (52.5)H4 1.02 (26) 2.17 (55)L1 2.91 (74) 3.8 (96.5)L3 0.37 (9.5) 0.51 (13)L4 1.14 (29) 1.1 (28)L5 0.41 (10.5) 0.51 (13)
A
0.079 (2)
H2H
1H
3
D1
X
X YB T
PA
Ø 1
.34
(3 4
); 0.
158
(4)
0.079 (2)
H4Ø
1.3
4 (3
4);
0.15
8 (4
)
M8 x 1
L1
1.06 (27)
2.13 (54)
L5
1.81
(46
)
L4
M8 x 1
Y
Z1
B A
M
G 1/4
M8 x 1
L3S
AE
-8; 3
/4–1
6[G
1/2
; 0.5
5 (1
4)]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
56
3
8
7
1
4
Directional valve4WE 10 D../…M-3SED10....
Orifice possible, if required state details
A
P Ta
A
P Ta
M-3SED 10 C../350…
M-3SEW 10 C../420…
M-3SED 10 U../350…
M-3SEW 10 U../420…
A
P T
Orifice in portModel (dia in 0.004 in (1/10 mm)
80 100 A B P T
x x GWA A** P** T**x x GWB B** P** T**
LFA – 6X1 2 3 4 10 11 12 13 17
Nominalsize
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
RA 21 010/06.98
29/36
H2
H1
H3
XL10.
079
(2)
Y
Y
L4
X
B A
AP
T1.28
(32
.5)
L3
L5
L2
0.158 (4)
L6
B
Z1
L7
0.15
8 (4
)H
4H5
M6
M6
1.22
(31)
0.158 (4)
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
B
A
Y
Aa
B
P TP10 B**
Z1 XX..
B
A
Y
Aa
B
P TP10 A**
Z1 XX..
Control cover for mounting a directional spool or poppet valve model ..KW .. : dim. in inches (mm)AB
Sizes 16 to 63
4 WE 6 D ../…
LFA..KWA-7X/…Sizes 25 and 32
4WE 6 D../…
LFA..KWB-7X/…Sizes 25 and 32
9
6 2
3
1 5
Directional valve4WE 6 D../…M-3SED6....
A
P T
aA
P Ta
M-3SEW 6 C../420…
A
P TM-3SED 6 U../350…
M-3SEW 6 U../420…
For item descriptionsee page 30
7
4
Directional poppet valveUM-3SEW 6 ../…C
Size 16 25 32 40 50 63H1 1.58 (40) 1.58 (40) 1.97 (50) 2.36 (60) 2.68 (68) 3.23 (82)H2 0.67 (17) 0.67 (17) 0.85 (21.5) 1.18 (30) 1.26 (32) 1.65 (42)H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)H4 – – – 1.18 (30) 1.26 (32) 1.18 (30)H5 – – – 1.18 (30) 1.97 (50) 2.36 (60)L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L2 3.15 (80) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L3 1.44 (36.5) 1.79 (45.5) 1.97 (50) 2.46 (62.5) 2.84 (72) 3.54 (90)L4 – – – 2.09 (53) 2.36 (60) 3.11 (79)L5 0.67 (17) 1.06 (27) 1.36 (34.5) 1.85 (47) 2.15 (54.5) 74.5L6 0.28 (7) 0.93 (23.5) 1.22 (31) 1.71 (43.5) 2.01 (51) 2.8 (71)L7 – – – 2.46 (62.5) 2.76 (70) 3.54 (90)
B
A
Y
Aa
B
P TP.. B**
Z1X..
X
YZ1
LFA..KWB-6X/…Sizes 40 to 63
B
A
Y
Aa
B
P TP.. A**
Z1
X..
X
YZ1
LFA..KWA-6X/…Sizes 40 to 63
XB
A
Z1X12
Y
B**P10
LFA16KWB-7X/…Size 16
XB
A
Z1X12
Y
A**P10
LFA16KWA-7X/…Size 16
For orifice ordering details see page 12.
M-3SED 6 C../350…
Orifice in portSize Model (dia in 1/10 mm)
A B P X
16 A** P0.39 (10) X0.47 (12)25 A** P0.39 (10) dia.0.059 (1.5)32 A** P0.39 (10) dia.0.079 (2.0)40 A** P0.47 (12) X0.47 (12)50 A** P0.59 (15) X0.59 (15)63 A** P0.71 (18) X0.71 (18)
16 B** P0.39 (10) X0.47 (12)25 B** P0.39 (10) dia.0.059 (1.5)32 B** P0.39 (10) dia.0.079 (2.0)40 B** P0.47 (12) X0.47 (12)50 B** P0.59 (15) X0.59 (15)63 B** P0.71 (18) X0.71 (18)
KWA
KWB
LFA –1 2 3 41) 10 11 12 14 17
12 SAE threaded external connectionsand UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Orifice hole (dia. in mm)
Standard orifice (dia. in 1/10 mm)
Orifice possible, if required state details(dia. in 1/10 mm)
Does not appearin the model code
1) 7X = series 7X (sizes 16, 25, 32)6X = series 6X (sizes 40, 50, 63)
RA 21 010/06.98
30/36
Control cover for mounting a directional spool or poppet valve model ..KW .. : dimensions in inches (mm)
Sizes 80 and 100
AB
B
A
Y
A
a
B
P TP20 A**
Z1
X20
X
YZ1
M
B
A
Y
A
a
B
P TP20 B**
Z1
X20
X
YZ1
M
4WE 10 D../…
LFA..KWA-6X/…Sizes 80 and 100
LFA..KWB-6X/…Sizes 80 and 100
A
P Ta
A
P Ta
1 Name plate for sizes 16, 25, 322 Name plate for sizes 40 to 1003 Ports Y and Z1 optionally as a threaded connection
for sizes 50, 634 Valve mounting bolts are included within the scope of
the control cover supply5 Plug ..KWB..6 Plug ..KWA..7 Shuttle valve9 M6 for sizes 16 and 40, M8 x 1 for sizes 50 and 63
M-3SED 10 C../350…
M-3SED 10 U../350…
M-3SEW 10 U../420…
A
P T
M-3SEW 10 C../420…
For orifice ordering details see page 12.
Size 80 100D1 9.84 (250) 11.8 (300)H1 3.94 (100) 4.33 (110)H2 0.77 (19.5) 1.06 (27)H3 1.77 (45) 2.07 (52.5)H4 2.36 (60) 2.76 (70)H5 2.05 (52) 2.44 (62)L1 2.17 (55) 2.17 (62)L3 0.26 (6.5) 0.2 (5)L6 0.26 (6.5) 0.079 (2)
A
H2
H1
H3
D1
X
X YBT
PA
0.079 (2)
H4
Ø 1
.34
(34)
; 0.1
58 (
4)
L3
1.06 (27)
2.13 (54)
1.81
(46
)0.59
(15
)
M8 x 1
Y
Z1
B A
M
L1
M8 x 1
M8 x 1
H5
0.079 (2)
L6
G 3/8
Ø 1.34 (34); 0.158 (4)
5
2
6
7
4
SA
E-8
; 3/4
–16
[G 1
/2; 0
.55
(14)
]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
SAE-8; 3/4–16[G 1/2; 0.55 (14)]
Directional valve4WE 10 D../…M-3SED10....
Directional poppet valveCM-3SEW 10 ../…U
Orifice in port (dia inModel 0.004 (1/10 mm)
80 100 A B P T X
x x KWA A** P0.79 (20) T** X0.79 (20)x x KWB B** P0.79 (20) T** X0.79 (20)
Nominalsize
1 2 3 4 10 11 12 13 14 17
LFA – 6X12 SAE threaded external connections
and UNC mounting bolts – BSP version
No code = NBR sealsV = FPM seals
(other seals on request)
Attention! The compatibility of the seals andpressure fluid has to be taken into account!
Orifice possible, if required state details
Standard orifice – does not appear in the model code
RA 21 010/06.98
31/36
X
XB
A
X**
Control cover with electrical monitoring of the closed position model ..E..(monitoring of closed spool position): dimensions in inches (millimeters)Technical data and notes are valid for all control covers withelectrical monitoring (..E.., ..EH2-.., ..EWA.., ..EWB..).
The solid state limit switch with integral amplifier switches when theclosed position is reached. This limit switch has the followingadvantages:
– No dynamic seals– Direct monitoring of the closed switched position of the valve– Long service life– Control cover and cartridge valve are included in the model
code– p
max = 5802 PSI (400 bar).
Size 16 25 32 40 50 63D1 G 1/8 G 1/4 G 1/4 G 1/2 G 1/2 G 3/4H1 1.97 (50) 1.97 (50) 2.76 (70) 4.72 (120) 5.12 (130) 5.91 (150)H2 0.47 (12) 0.63 (16) 0.63 (16) 3.54 (90) – –H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)T1 0.32 (8) 0.47 (12) 0.47 (12) 0.55 (14) 0.55 (14) 0.63 (16)
For orifice ordering details see page 12.
1 Name plate3 Port X optionally as a threaded port9 M8 x 1 for sizes 40 and 50, G 3/8 for size 6310 Limit switch ...QM (included within the model
code, see page 34)11 Plug-in connector K24 (must be ordered
separately, see page 34)12 Limit switch ...Q0 (included within the model
code, see page 35)13 Plug-in connector (included within the model
code, loose supply)14 Space required to remove plug-in connector
Sizes 16 to 63
Sizes 16 to 32
LFA..E-7X/C…DQM...Sizes 16 to 32
LFA..E-6X/C…DQ0...Sizes 40 to 63
X**X
XB
A
Sizes 40 to 63
H2H
1H
3
X
L1
max
. 2.9
5 (7
5)
0.158 (4)
X**
M8
D1/T1
H2H
1H
3
X
H5
L1
X**
D1/T1
1.77 (45)1.38 (35)0.63 (16)
3.86
(98
)
3
1
1110
14
13
9
112
Ø1.58 (40)
0.158 (4)
Limit switch
Connection, function, pin allocation see page 34.
Attention!The limit switch outputs are only protected against load shortcircuits.
The +24 V outlets are to be protected against short circuits.
Nominal size
16 25 32 40 50 63
x x x x x x
Area ratioA1:A2
CA = 2:1 2)
CB = 14.3:1 3)
Crackingpressure pÖ
10 =14.5 PSI1.0 bar
20 =29 PSI2.0 bar
40 =58 PSI4.0 bar
Orifice possible, if required statedetails (dia. in 0.004 inches (1/10 mm)
1) 7X = series 7X (sizes 16, 25, 32)6X = series 6X (sizes 40, 50, 63)
2) Annulus area = 50%3) Annulus area = 7%4) For sizes 16 to 325) For sizes 40 to 63
LFA E – D F1 2 3 41) 5 6 7 8 9 14 17
QMG24 4)
Q0G24 5)
No code = NBR sealsV = FPM seals
(other seals on request)
Attention!The compatibility of the seals and
pressure fluid has to be taken into account!
Orifice inport
(dia. in0.004 in
(1/10 mm)
X**
RA 21 010/06.98
32/36
X X
H2
H5
X
3.15 (80)
0.158 (4)
X**
D1/T1
H1
H3
H6
L1
M6
L2
0.07
9 (2
)
max. 2.95 (75)
H5
X H4
X**
D1/T1
H1
H3
H6
L1
3.15
(80
)0.
63 (
16)
L2
2.72 (69)
3.5 (89)
M8 x 1
1A/F
2A/F
12
1413
1110
1
153
2A/F
1A/F
1
Ø1.
58 (
40)
0.158 (4)
Sizes 16 to 63
Size 16 25 32 40 50 63D1 G 1/8 G 1/4 G 1/4 G 1/2 G 1/2 G 3/4H1 1.38 (35) 1.58 (40) 1.97 (50) 5.51 (140) 5.91 (150) 6.69 (170)H2 1.97 (50) 1.97 (50) 1.97 (50) – – –H3 0.59 (15) 0.95 (24) 1.1 (28) 1.26 (32) 1.34 (34) 1.97 (50)H4 0.98 (25) 0.98 (25) 0.98 (25) 1.18 (30) 1.3 (33) 1.18 (30)H5 4.96 (126) 5.12 (130) 5.91 (150) 6) 6.5 (165) 6) 7.68 (195) 6) 9.25 (235) 6)
H6 2.44 (62) 2.6 (66) 2.6 (66) 3.54 (90) 3.94 (100) 4.41 (112)L1 2.56 (65) 3.35 (85) 3.94 (100) 4.92 (125) 5.51 (140) 7.09 (180)L2 1.28 (32.5) 1.67 (42.5) 1.97 (50) 2.84 (72) 3.15 (80) 3.54 (90)T1 0.315 (8) 0.47 (12) 0.47 (12) 0.55 (14) 0.55 (14) 0.63 (16)
SW1 0.236 (6) 0.236 (6) 0.394 (10) 0.47 (12) 0.67 (17) 0.75 (19)SW2 0.83 (21) 0.83 (21) 1.06 (27) 1.42 (36) 1.81 (46) 2.17 (55)
6) max. dim.For orifice ordering details see page 12.
LFA..EH2-7X/C...DQM...Sizes 16 to 32
X**
XX
B
A
X**X
XB
A
LFA..EH2-6X/C...DQ0...Sizes 40 to 63
Sizes 16 to 32 Sizes 40 to 63
Control cover with electrical monitoring of the closed position and stroke limitermodel ..EH2-.. (monitoring of closed spool position): dimensions in inches (millimeters)
1 Name plate3 Port X optionally as a threaded connection10 Limit switch ...QM (included within the
model code, see page 34)11 Plug-in connector K24 (must be ordered
separately, see page 34)12 Limit switch ...Q0 (included within the model
code, for electrical data see page 35)13 Plug-in connector (included within the
model code, supplied as loose item)14 Space required to remove plug-in connector15* For size 16 (length)
Orifice possible, if required state details1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)2) Annulus area = 50%3) Annulus area = 7%4) For sizes 16 to 325) For sizes 40 to 63
No code = NBR sealsV = FPM seals
(other seals on request)
Attention!The compatibility of the seals and pressure
fluid has to be taken into account!
Nominal size
16 25 32 40 50 63
x x x x x x
Area ratioA1:A2
CA = 2:1 2)
CB = 14.3:1 3)
Crackingpressure pÖ
10 =14.5 PSI1.0 bar
20 =29 PSI2.0 bar
40 =58 PSI4.0 bar
LFA EH2– D F1 2 3 41) 5 6 7 8 9 14 17
QMG24 4)
Q0G24 5)
Orifice inport (dia.in 0.004 in(1/10 mm)
X**
*
RA 21 010/06.98
33/36
A
H2
X
H1
H3
L11.
28 (
32.5
)
0.07
9 (2
)
X Y
T
PB A
1.6 (40.5)L3 M6
B A
M6 M6
H4
Y
M6
L2
1110
56
1
max. 2.95 (75)
4
Ø1.
58 (
40)
Sizes 16 to 32
Sizes 16 to 63
1 Name plate 4 Valve mounting bolts are included
within the scope of the controlcover supply
5 Plug M6 for ..EWB... 6 Plug M6 for ..EWA...
4WE 6 D...
Directional valve4WE 6 D…M-3SED6....
Control cover with electrical monitoring of the closed position for mounting a directional spool orpoppet valve model ..EW .. (monitoring of closed spool position): dimensions in inches (millimeters)A
B
1) 7X = series 7X (sizes 16, 25, 32)
6X = series 6X (sizes 40, 50, 63)2) Annulus area = 50%3) Annulus area = 7%4) For sizes 16 to 325) For sizes 40 to 63
Directional poppet valveUM-3SEW 6 ../…C
Size 16 25 32H1 1.58 (40) 1.58 (40) 1.97 (50)H2 1.97 (50) 1.97 (50) 1.97 (50)H3 0.59 (15) 0.95 (24) 1.1 (28)H4 0.98 (25) 0.98 (25) 0.98 (25)L1 2.56 (65) 3.35 (85) 3.93 (100)L2 3.15 (80) 3.35 (85) 3.93 (100)L3 0.276 (7) 0.93 (23.5) 1.22 (31)L4 0.67 (17) 1.06 (27) 1.36 (34.5)
For orifice ordering details see page 12.
10 Limit switch ...QM (included within themodel code, see page 34)
11 Plug-in connector K24 (must be orderedseparately, see page 34)
XB
A
Y
A B
P TP** T** A**
LFA.EWB-7X/…Sizes 16 to 32
LFA.EWA-7X/…Sizes 16 to 32
XB
A
Y
A B
P TP** T** B**
No code = NBR sealsV = FPM seals
(other seals on request)
Attention!The compatibility of the seals and
pressure fluid has to betaken into account!
Orifice in port(dia. in 1/10 mm)
A B P T
A** P** T**B** P** T**
Nominal size Model
16 25 32 40 50 63
x x x x x x EWAx x x x x x EWB
LFA – D1 2 3 41) 5 6 7 8 10 11 12 13 17
Orifice possible, if required state details
Crackingpressure pÖ10 =14.5 PSI
(1.0 bar)20 =29 PSI
(2.0 bar)40 =58 PSI
(4.0 bar)
Area ratioA1: A2
CA = 2:1 2)
CB = 14.3:1 3)
QMG24 4)
Q0G24 5)
A
P T
A
P T
M-3SED 6 C../350…
M-3SEW 6 C../420…
A
P T
M-3SED 6 U../350…
M-3SEW 6 U../420…
RA 21 010/06.98
34/36
A
X
H1
H3
L1
3.15
(80
)0.
63 (
16)
1.28
(32
.5)
2.72 (69)
3.5 (89)
X Y
T
PB A
1.6 (40.5)L3
L41.
22 (
31)
M6
B A
M6 M6
Y H4
G 1/2; 0.551 (14)G 1/4; 0.47 (12) (NG 40)
0.158 (4) M6
56
3 3
14111 10
4
Sizes 40 to 63
For orifice ordering details see page 12.
1 Name plate3 Ports X and Y optionally as a threaded connection4 Valve mounting bolts are included within the scope of the
control cover supply5 Plug M6 for ..EWB...6 Plug M6 for ..EWA...
10 Limit switch ...Q0 (included within the model code,electrical data see page 34)
11 Plug-in connector (included within the model code,supplied as loose item)
14 Space required to remove plug-in connector
Size 40 50 63H1 4.72 (120) 5.12 (130) 5.91 (150)H3 1.26 (32) 1.34 (34) 1.97 (50)H4 1.18 (30) 1.18 (30) 1.18 (30)L1 4.92 (125) 5.51 (140) 7.09 (180)L3 1.71 (43.5) 2.01 (51) 2.8 (71)L4 1.85 (47) 2.15 (54.5) 2.93 (74.5)
Directional valve4WE 6 D…M-3SED6....
Control cover with electrical monitoring of the closed position for mounting a directional spool orpoppet valve model ..EW .. (monitoring of closed spool position): dimensions in inches (millimeters)A
B
Directional poppet valveUM-3SEW 6 ../…C
LFA.EWA-6X/…Sizes 40 to 63
XB
A
Y
A B
P TP** T** A**
a
X Y
A
P T
A
P T
XB
A
Y
A B
P TP** T** B**
a
X Y
LFA.EWB-6X/…Sizes 40 to 63
4WE 6 D...
M-3SED 6 C../350…
M-3SEW 6 C../420…
A
P T
M-3SED 6 U../350…
M-3SEW 6 U../420…
RA 21 010/06.98
35/36
Inductive limit switch model QM, electrical connections (for nominal sizes 16… 32 mm)
The electrical connection is via a 4-pin connector which has a M12x 1 connection thread.
The plug-in connector has to be separately ordered (see below).
PNP
0 V+ 24 V
321 4
NOpen
NClosed
The model QM inductive limit switch can beconnected either as normally closed or normallyopen.
Operating voltage: 24 V DC
(residual ripple < 10%)
Current consumption: max. 40 mA
Output loadrating: 400 mA (output to PNP 24 V =)
Temperature range: –4° F to +176° F (–20° C to +80° C)
Pin allocation: 1: +24V2: Normally closed (low resistance –
high resistance)3: 0 V4: Normally open (high resistance –
low resistance)
+ 20 %– 10 %
Load capacityto 400 mA
Plug-in connector for model QM inductive limit switch (must be ordered separately): dimensions in inches (millimeters)
Plug-in connector suits a K24 4-pin, M12 x 1 with threadedconnection, cable fitting Pg 9.
Part no. 00 031 155
Plug-in connector, K24 4-pin, M12 x 1 with moulded on PVC cable,118 inches (3m) long.
Cable cross section: 4 x 22 AWG (4 x 0.34 mm2)
Core identification: 1: brown2: white3: blue4: black
Part no. 00 064 381
1.63 (41.5)M
12 x
1
Ø0.
57 (
14.5
)
Plug-in contactson the limit switch
The limit switch does not have an earth connection!
2.13 (54)
M12
x 1
Ø0.
71 (
18)
1 2
34
M12
x 1
Ø0.
772
(19.
6)
1.35 (35)
appr
ox. 1
.58
(40)
Ø0.58 (14.8)
Plug-in connector suits a K24 4-pin, M12 x 1 with threadedconnection, cable fitting Pg 9, angled.
Housing can be rotated about the contact insert 4 x 90°.
Part no. 00 082 899
RA 21 010/06.98
36/36
Inductive limit switch model Q0. electrical connection (for nominal sizes ≥40 mm)
The electrical connection is via a plug-in connector model "Z"(red) and a Pg11 fitting.
Operating voltage: 24 V DC
(residual ripple < 10%)
Load rating: 400 mA (output to PNP 24 V =)
Temperature range: +14° F to +176° F (–10° C to +80° C)
Pin location: 1: 0 V2: Normally closed (low resistance –
high resistance)3: 24 V +4: Normally open (high resistance – low
resistance)
The limit switch does not have an earth connection!
+ 20 %– 10 %
PNP
0 V+ 24 V
3 2 14
NOpen
NClosed
The model Q0 inductive limit switch can be connectedeither as normally closed or normally open.
Note: Four pin connector (red) may be ordered via part number 0000 5538.
Load capacityto 400 mA
Mannesmann Rexroth Corporation Rexroth Hydraulics Div., Industrial, 2315 City Line Road, Bethlehem, PA 18017-2131 Tel. (610) 694-8300 Fax: (610) 694-8467Rexroth Hydraulics Div., Mobile, 1700 Old Mansfield Road, Wooster, OH 44691-0394 Tel. (330) 263-3400 Fax: (330) 263-3333
All rights reserved – Subject to revision Printed in U.S.A.