2 wire speed sensor - headwindsolutions.ca

4
Installation Instructions 2 WIRE SPEED SENSOR

Upload: others

Post on 07-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2 WIRE SPEED SENSOR - headwindsolutions.ca

Installation Instructions 2 WIRE SPEED SENSOR

Page 2: 2 WIRE SPEED SENSOR - headwindsolutions.ca

Step1

Drill and tap into bell housing directly over top of the ring gear if there isn’t a hole already available.

Page 3: 2 WIRE SPEED SENSOR - headwindsolutions.ca

Step 2

Thread magnetic sensor in until it touches the ring gear, then back off 1/2 - 3/4 turn and then tighten jam nut.

Page 4: 2 WIRE SPEED SENSOR - headwindsolutions.ca

Step 3

Wiring of speed sensor Run one wire from the speed sensor to the RPM terminal in the rev limiter box. Run the other wire from the speed sensor to the ground location. As the two wire speed sensor is a non-polarized AC sensor, either wire can be run to the RPM terminal and/or ground.

©2018 Headwind Solutions. All rights reserved. 1-844-304-7277

www.headwindsolutions.ca V1.01/17 May 2018