2000/3000 liter vhp - chart industries,...
TRANSCRIPT
- 1 -
2000/3000 Liter VHP
Operating Manual Manual #10961999 - Addendum
- 2 -
TABLE OF CONTENTS 1 Overview 3 2 Illustrations & Parts Listings 4 3 Specifications 14 Revision Log Description
Rev A (12/03)
Initial product release
Rev B (8/11)
Added 3000 liter and top/bottom fill tanks and updated float models.
OVERVIEW 1
- 3 -
The Perma-Cyl 2000/3000 is an innovative design evolving from proven technology we have been using for years on our liquid cylinders and bulk storage tanks. What makes the Perma-Cyl design revolutionary is the fast fill capability, no loss/low loss fill with automatic fill termination, extended hold time and telemetry compatibility. When filled by an Orca, the Perma-Cyl vessel is designed to have an actual fill-time of three minutes or less (smaller models) with zero losses under normal conditions. The vessel will allow liquid to be held for long periods without venting, limiting product losses during periods of nonuse. The new Cyl-Tel gauge features an accurate user-friendly display and is “telemetry ready” to connect to Chart’s multiple telemetry platforms. This manual is an addendum to include the new Perma-Cyl 2000 & 3000 VHP models. For all filling, operating and safety instruction, please refer to the standard Perma-Cyl Operating Manual (PN 10961999). This cylinder was designed for the volume MicroBulk user in mind. The cylinder uses the most advanced pressure building and vaporization technology today. Below are the overall dimensions of the cylinder. Replacement parts and cylinder specifications are in the sections that follow.
ILLUSTRATIONS AND PARTS LISTING 2
- 4 -
PERMA-CYL 2000 VHP STD TOP FILL - DIMENSIONS/ COMPONENTS
TOP VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 5 -
FRONT VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 6 -
PERMA-CYL 2000 VHP TOP&BTM FILL - DIMENSIONS/ COMPONENTS
TOP VIEW
13
ILLUSTRATIONS AND PARTS LISTING 2
- 7 -
FRONT VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 8 -
PERMA-CYL 3000 VHP STD TOP FILL - DIMENSIONS/ COMPONENTS
TOP VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 9 -
FRONT VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 10 -
PERMA-CYL 3000 VHP TOP&BTM FILL - DIMENSIONS/ COMPONENTS
13
ILLUSTRATIONS AND PARTS LISTING 2
- 11 -
FRONT VIEW
ILLUSTRATIONS AND PARTS LISTING 2
- 12 -
PERMA-CYL 2000/3000 VHP STANDARD TOP FILL:
ITEM PART NO. DESCRIPTION 1 11656072 Check Valve 1” 600WOG
2 11051090 Check Valve 1/2” FPT x
1/2” FPT
3 1812702 Line Relief Valve (550PSI)
4 11529090 Line Strainer ½”
5 11635511 PB Regulator ½” 450 psi
6 13909811 Pressure Gauge (0-600
PSI)
7 11627651 5-Way Valve
8 15087831 Cyl-Tel Gauge
ITEM PART NO. DESCRIPTION 9 13462175 Check Valve ½”
WOG
10 11385111 Relief Valve (500PSI)
11 11526622 Rupture Disk (700PSI)
12 1712202 Rupture Disk
(700PSI)
13 10616790
ILLUSTRATIONS AND PARTS LISTING 2
- 13 -
PERMA-CYL 2000/3000 VHP STANDARD PRODUCT
CONNECTIONS: ITEM PART NO. DESCRIPTION
4010022 Outlet 3/8" MPT (INERT)
4010012 Outlet 3/8" MPT (OXY)
1110122 Connection 1/2” ODT x 1/2” (45° Flare-Inert)
1110912 Connection 5/8” ODT x
1/2” (45° Flare-OXY)
SPECIFICATIONS 3
- 14 -
* CO² = 450 SCF/H
Description 2000 Liter 3000 Liter
VHP Pallet VHP Pallet
Base Base
Capacity (liters)
Gross 2,042 Gross 2,911
Net 1,945 Net 2,707
MAWP psig 500 psig 500
bar 34.5 bar 34.5
Design Spec ASME SECTION VIII DIV I
Storage Capacity
Nitrogen SCF 47,847 SCF 66.592
Nm3 1,257 Nm3 1,750
Oxygen SCF 59,089 SCF 82,239
Nm3 1,553 Nm3 2,161
Argon SCF 57,786 SCF 80,425
Nm3 1,519 Nm3 2,115
Carbon Dioxide SCF 38,048 SCF 52,954
Nm3 1,000 Nm3 1,390
Thermal Performance
N
1%
(NER%/Day) O2 – Ar
CO2
0.62%
.3%
Gas Delivery Rate *
SCF/H 2,000 SCF/H 2,000
Nm3h 52.4 Nm3h 52.4
Dimensions
Diameter in 48 in 58
mm 1,219 mm 1,473
Tare Weight lbs 2,600 lbs 4,250
Kg 1,179 Kg 1,928
Height in 119-1/2 in 122-3/8
mm 3,035 mm 3,108