2006 02 · sok adp40 £19.95 48 sok adp50 £19.95 48 sok adp60 £29.95 48 sok adp65 £33.95 48 sok...

17
2006 02 www.socketandsee.co.uk

Upload: others

Post on 27-Jan-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

200602www.socketandsee.co.uk

Put us to the Test!Socket & See are committed toproviding the easiest to usetesters on the market.

All our testers are guaranteedagainst manufacturing defect fortwo years from date of purchase.

Quality and ValueSocket & See and MajorTech are dedicatedto producing professional testers at pricesthat make sense!

Designed for you!With our unique Socket & See values ourtesters have been designed for both theprofessional and newly qualified tradesman- Electricians, Plumbers, HVAC Engineers,for the tests you need to carry out every day.

Distributor Freephone Sales Order Fax

0800 7831385Visit our websites

www.socketandsee.co.ukwww.major-tech.co.uk

e-mail: [email protected] Tel: +44 (0)1256 864100Fax: +44 (0)1256 864164

Socket & See (A division of the Kew TechnikGroup of companies)

Prices: All prices shown in this brochure exclude VAT and are effective from 1 June 2006

Before, I didn’t think we would be finished with our task until the end of March. Now, with the Fuse Finder on the job, we should be wrapping up in a couple of weeks.

Floyd H. Rodgers Director of Circuit Study, The Woodstock Opera House, USA

A week ago I was busy testing and repairing some electricalproblems at our garage. I was finished, for the day and was almoston my way home. I was just tidying up the DB box and pushing awire into place, when there was a BIG flash!!! When I opened my

eyes, the pair of long-nose pliers was lying about 6m from me. I do not know how it got out of my hand, but I was happy that it was OUT, and that I was still alive…Lucky...? Although luck counts, I think it is because I bought a KEW TECHNIK tool!Thank you for saving my life.

G Stander South Africa

BEFORE

AFTER

Kew Technik is QualityAssured to ISO 9001

New to Part P or Experienced Electrician?There is a simple grouping of Socket & See testers to point you inthe right direction. If we take Insulation/Continuity testers as anexample:

PDIT 360 is an easy to use tester ideally suited to new comers toelectrical testing and covers all the major tests required by the16th Edition to meet Part P requirements.

DIT 400 PLUS is also easy to use, but has 3 extra features theexperienced electrician will value:-

In addition to 250 and 500 volt insulation testing it has a 1000volt range for testing in Industrial situations. SFS (Super FastSystem) is a new go-no-go fast test - ideal for testing at the ‘build stage’ of a property, thus saving time and money. It is alsosupplied complete with an SS 130, 13A socket interface whichmeans not having to take the socket off the wall for testing.

I found Fuse Finder really useful, and it is something I wouldmake a lot of use of.

Mark Wildish Burdock Electrical, UK

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

ContentsInsulation/Continuity Testers . . . . . . . . .3/4

Multifunction Loop Testers . . . . . . . . . .5-12

Multifunction RCD Testers . . . . . . . . .13/14

Test Kits . . . . . . . . . . . . . . . . . . . . . . .16/17

Digital Multimeters . . . . . . . . . . . . . . .18-20

Clamp Meters . . . . . . . . . . . . . . . . . . .21-23

Test Leads . . . . . . . . . . . . . . . . . . . . . .23-26

13A Socket Testers . . . . . . . . . . . . . . .27-33

Industrial Socket Testers . . . . . . . . . . .34-38

Phase Testers . . . . . . . . . . . . . . . . . . . .39-41

Fuse Finders . . . . . . . . . . . . . . . . . . . .42-46

Dead Circuit Finder . . . . . . . . . . . . . . . . . .47

Carrying Cases . . . . . . . . . . . . . . . . . . . . .48

Socket Tester Adaptors . . . . . . . . . . . . . . .48

Voltage Testers . . . . . . . . . . . . . . . . . .49/53

Socket Opener . . . . . . . . . . . . . . . . . . . . .48

Test Documentation . . . . . . . . . . . . . . . . .49

Thermometers . . . . . . . . . . . . . . . . . . . . . .50

Temperature Probes . . . . . . . . . . . . . . . . .51

Temperature Monitoring Kits . . . . . . . . . .51

Light Meter . . . . . . . . . . . . . . . . . . . . . . . .52

Ultra-sonic Distance Meter . . . . . . . . . . .52

STEP BY STEP

AVAILABLEGUIDE

Model No. Price Page

DCF 200 £149.95 47

DIT 400 £189.95 4

DIT 400 PLUS £199.95 4

DL 420 £199.95 11

DL 420 PLUS £229.95 12

EIC 002 £14.95 49

EPF 10 £9.95 40

EPF 20 £14.95 40

EPF 30 £29.95 40

FFCB 100EU £54.95 43

FFCB 100UK £54.95 43

FFCB 1130UK £129.95 45

FFCB 1140UK £149.95 46

FFCB 200EU £99.95 44

FFCB 200UK £99.95 44

FFR HLT £5.95 41

IECP UKA £4.95 25

IT 001 £14.95 26

ITLS 400 £34.95 15/24

ITLS 440 £29.95 25

ITLS 450 £29.95 25

ITS 003 £14.95 49

KTVT 100 £14.95 53

MEW 001 £14.95 49

MT 130 £59.95 52

MT 1879A £84.95 20

MT 1887A £105.95 20

MT 2002PA £259.00 23

MT 21A £31.95 19

MT 22A £41.95 19

MT 24A £52.95 19

MT 2434 £249.00 23

Model No. Price Page

MT 400 £14.95 53

MT 470 £39.95 53

MT 630 £59.95 50

MT 632 £79.95 50

MT 650 £159.00 51

MT 651 £14.95 50

MT 652 £179.00 51

MT 660 £6.95 51

MT 670 £29.95 51

MT 672 £24.95 51

MT 675 £29.95 51

MT 680 £29.95 51

MT 685 £29.95 51

MT 690 £79.95 51

MT 694 £89.95 50

MT 695 £139.95 50

MT 730 £69.95 22

MT 770 £89.95 22

MT 777 £159.95 22

MT 940 £39.95 52

NCT 0314 £4.95 49

NCT 0316 £4.95 49

PDIT 360 £179.95 3

PDL 200 £79.95 6/33

PDL 234 £89.95 7

PDL 234 PLUS £119.95 8

PDL 310 £179.95 9

PDL 310 PLUS £199.95 10

PDRC 380 £179.95 14

PIR 004 £14.95 49

PKIT 300 £549.00 17

SBX 4AA £2.95 48

Model No. Price Page

SOK A20 £19.95 26

SOK ADP40 £19.95 48

SOK ADP50 £19.95 48

SOK ADP60 £29.95 48

SOK ADP65 £33.95 48

SOK 12 £9.95 29

SOK 13SO £0.49 48

SOK 22 £14.95 29

SOK 32 £19.95 29

SOK 40/16HD £29.95 36

SOK 40/32HD £34.95 36

SOK 42EU £29.95 31

SOK 42UK £29.95 31

SOK 420EU £89.95 32

SOK 420UK £89.95 32

SOK 50/16HD £29.95 35

SOK 50/32HD £34.95 35

SOK 60/TCN £64.95 38

SOK 60/16HD £54.95 37

SOK 60/32HD £59.95 37

SOK 605/16 £29.95 48

SOK 605/32 £33.95 48

SOK 65/16HD £59.95 37

SOK 65/32HD £64.95 37

SOK 72EU £69.95 41

SS 130 £14.95 26

TECC 10 £14.95 48

TECC 30 £29.95 48

TECC 40 £19.95 48

TECC 50 £29.95 48

A-Z Listing

FREE

INSULATION LOOP

SEE OUR KEW TECHNIKTOOLS CATALOGUE

RCD

Easy step by step guides to successfulPart P testing are available by mail oronline at www.socketandsee.co.uk

1

Conte

nts

Insulation/Continuity Testers

Insulation/Continuity Testers

www.socketandsee.co.uk2

DIT 400 16th Edition

Insulation/Continuity Tester

£189.95

PDIT 360 Part P 16th Edition

Insulation/Continuity Tester

£179.95

PRODUCT

FEATURES

PRICE

DIT 400 PLUS 16th Edition

Insulation/Continuity Tester

Includes high quality test leads � � �

5000 tests (@ 500V) from 4 AA cells � � �

Continuity test with full 200mA output � � �

Test lead null � � �

Insulation Test with full 1mA output � � �

250 Volt test � � �

500 Volt test � � �

1000 Volt test � �

SFS (Super Fast System) Insulation and Continuity � �

SS 130 13A Socket Interface �

£199.95

Insu

lation/C

ontin

uity Testers

Insu

lation/C

ontinuity

Test

ers

3

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

PDIT 360Part P Insulation/ContinuityTesterFull Part P verification

Additional/spare Test Leads available - see page 23-25

WHAT’S INCLUDED

PDIT 360 Part P Insulation/ Continuity Tester £179.95

IT 001 Test Lead Kit Included

PDITINS 360 Instruction Manual Included

TECC 10 Carrying Case Included

PDIT 360 £179.95

� 2 way-250, and 500 Volt insulation plus full 200mA continuity test

� Continuity measurement up to 10KΩ

� Uses only 4 x AA alkaline batteries giving over 5000 tests at 500V

� Supplied complete with quality test leads, carrying case and manual

� Fully protected against accidental live voltage contact up to 600V AC

� Null Function to eliminate lead resistance up to 2Ω

� Intelligent auto shut off to preserve battery life

16TH EDITION COMPLIANCE413-02-12 & Table 41C Measurement of R1 + R2

413-04-01 to 07 Protection by non-conducting walls and floors713-02 Continuity of protective conductors713-03 Continuity of ring final circuit conductors713-04-01 to 04 Insulation resistance713-05-01 & 02 Site applied insulation713-08-01 & 02 Insulation of non-conducting walls and floors713-09 Polarity

NEWVERIFICATION

PARTEDITION FULLY CERTIFIED

BS EN61557

GUIDE INCLUDED

STEP BY STEP

Insulation Test RangesAccuracyTest Voltage Ranges (Auto Range) Tolerance (@200C)

0.01 to 9.99MΩ ± 3% ± 1 digit250V 10.0 to 99.9MΩ ± 3% ± 1 digit

100 to 199MΩ ± 6% ± 1 digit0.01 to 9.99MΩ ± 3% ± 1 digit

500V 10.0 to 99.9MΩ ± 3% ± 1 digit100 to 199MΩ ± 3% ± 1 digit200 to 500MΩ ± 6% ± 1 digit

Output VoltageVoltage Load Output Current Tolerance250 250kΩ 1mA -0% +20%500 500kΩ 1mA -0% +20%Short circuit current (in to 2kΩ) <2mATypical Test Time (10MΩ) <2 sec

Continuity Test RangesAccuracy Ranges (Auto Range) Tolerance (@ 200C)0.00 to 9.99Ω ± 3% ± 2 digits10.0 to 99.9Ω ± 3% ± 2 digits100 to 999Ω ± 3% ± 2 digits1000 to 9999Ω ± 3% ± 2 digitsOpen Circuit Voltage >4V, <10VShort Circuit Current >200mAZero offset Adjust (Test Lead Null) 2ΩTypical Test Time (2Ω) <2 sec

Power4 x AA alkaline batteries (not included)Battery Life (BS EN 61557) >5000 tests @ 500V test voltage

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . 80% @ 310C to 50% @ 400CSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157mm x 89mm x 39mmWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400g

Insulation/Continuity Testers

www.socketandsee.co.uk4

DIT 400 PLUS16th Edition DigitalInsulation/Continuity TesterFull 16th Edition Certification

� New patented Super Fast System (SFS®) gives super fast time saving results

� As well as saving time, SFS greatly extends battery life

� 3 way-250, 500 and 1000 Volt insulation plus full 200mAcontinuity test

� Continuity measurement resolution 0.01Ω

� Uses only 4 x AA alkaline batteries giving over 5000 tests at 500V

� Supplied complete with quality test leads, carrying case and manual

� Fully protected against accidental live voltage contact up to 600V AC

� Null Function to eliminate lead resistance up to 2Ω

� Intelligent auto shut off to preserve battery life

Insu

lation/C

ontin

uity Testers

Insulation Test RangesAccuracy (Cert mode)Test Voltage Ranges (Auto Range) Tolerance (@200C)

0.01 to 9.99MΩ ± 3% ± 1 digit250V 10.0 to 99.9MΩ ± 3% ± 1 digit

100 to 199MΩ ± 6% ± 1 digit0.01 to 9.99MΩ ± 3% ± 1 digit

500V 10.0 to 99.9MΩ ± 3% ± 1 digit100 to 199MΩ ± 3% ± 1 digit200 to 500MΩ ± 6% ± 1 digit0.01 to 9.9MΩ ± 3% ± 1 digit

1000V 10.0 to 99.9MΩ ± 3% ± 1 digit100 to 399MΩ ± 3% ± 1 digit400 to 999MΩ ± 6% ± 1 digit

Output Voltage (Cert and SFS mode)Voltage Load Output Current Tolerance250 250kΩ 1mA -0% +20%500 500kΩ 1mA -0% +20%1000 1MΩ 1mA -0% +20%Short circuit current (in to 2kΩ) <2mATypical Test Time (cert mode) (10MΩ) <2 secTypical Test Time (SFS mode) (10MΩ) <1 secSFS Threshold 2MΩ

Continuity Test RangesAccuracy (Cert mode) Ranges (Auto Range) Tolerance (@ 200C)0.00 to 9.99Ω ± 3% ± 2 digits10.0 to 99.9Ω ± 3% ± 2 digits100 to 999Ω ± 3% ± 2 digits1000 to 9999Ω ± 3% ± 2 digitsOpen Circuit Voltage >4V, <10VShort Circuit Current >200mAZero offset Adjust (Test Lead Null) 2ΩTypical Test Time (Cert mode) (2Ω) <2 secTypical Test Time (SFS mode) (2Ω) <1 secSFS Threshold 10Ω

Power4 x AA alkaline batteries (not included)Battery Life (BS EN 61557) >5000 tests @ 500V test voltage

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . 80% @ 310C to 50% @ 400CSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157mm x 89mm x 39mmWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400g

NEWEDITION FULLY CERTIFIED

BS EN61557

SUPER FASTSYSTEM

16TH EDITION COMPLIANCE413-02-12 & Table 41C Measurement of R1 + R2

413-04-01 to 07 Protection by non-conducting walls and floors713-02 Continuity of protective conductors713-03 Continuity of ring final circuit conductors713-04-01 to 04 Insulation resistance713-05-01 & 02 Site applied insulation713-08-01 & 02 Insulation of non-conducting walls and floors713-09 Polarity

Additional/spare Test Leads available - see page 23-25

ContentsDIT 400 16th Edition Insulation

Continuity Tester £189.95

SS 130 Socket Interface £14.95

IT 001 Test Lead Kit Included

DITINS 400 Instruction Manual Included

TECC 10 Carrying Case Included

£204.90

DIT 400 PLUS £199.95with SS 130 Socket Interface

ALSO AVAILABLE

DIT 400 (SS 130 not included) £189.95

KITSAVERPRICE

IT 001 SS 130

WHAT’SIN THE KIT

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

Loop T

este

rs

Loop Testers

5

PDL 310 PLUS

Multifunction Loop Test Kit

£199.95

DL 420M

ultifunction 16th Edition Loop Test

£199.95

DL 420 PLUS

Multifunction 16th Edition Loop Test Kit

£229.95

PDL 310

Multifunction Loop Tester

£179.95

PDL 234 PLUS

Multifunction Part P Loop Test Kit

£119.95

PDL 234

Multifunction Part P Loop Tester

£89.95

PDL 200

Multifunction Part P Loop Tester

£79.95

No-trip Loop test � � � � � � �

Measures mains voltage � � � � � � �

Correct socket wiring test � � � � � � �

Correct Polarity safety test � � � � � � �

Circuit verification � � � � � � �

Direct LED readout of results � � �

Digital (LCD) readout of result � � � �

Measures PFC (Prospective Fault Current) � � � �

Uses impedance measurement for Loop/PFC � �

Measures voltage phase - neutral � � � � � � �

Measures voltage phase - earth & neutral - earth � �

Supplied with ITLS 400 fused test lead set � � �

PRODUCT

FEATURES

PRICE

Loop Testers

www.socketandsee.co.uk

Wiring TestDetects missing E or N (>15kΩ)Detects L-E or L-N swapDetects Live - Earth/Neutral reversal by use of Polarity Test PadFault indicated by chart on front of instrumentPhase voltage measurement accuracy 1% and displayed on 3 LED’s

<207V AC LOW207-253V AC STANDARD>253V AC HIGH

Loop TestContinuous reading loop resistance (Rl + Re) with result displayed on 5 LED’sTest current <15mA at 253V AC

Range<1Ω<2Ω<20Ω<200Ω>200Ω

Each breakpoint has an accuracy of ± 10%Test stops within 30ms if measured EARTH potential >25V AC and ‘Earth Fault’ indication displayed

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . 80% @ 310C to 50% @ 400CSize . . . . . . . . . . . . . . . . . . . . . . . . . . 140mm x 80mm x 31mm with fixed leadWeight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250g

StandardsCE MarkedComplies with BS EN 61010-1: 300V Cat IIIComplies with BS EN 61326 (with amendment A1)

PDL 200Multifunction Part P Loop TesterEasy to use Part P verification

� 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Accurate mains voltage measurement to latest BS 7697, HD 472 S1

� Built in proven SOK 32 correct wiring indication - see page 30for complete fault indication chart

� Unique Socket & See Polarity test gives ultimate overallsystem safety check

� Carrying case included

NEWVERIFICATION

PARTGUIDE INCLUDED

STEP BY STEP

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

Loop Testers

6

WHAT’S INCLUDED

PDL 200 Part P Loop Tester £79.95

PDLINS 200 Instruction Manual Included

TECC 10 Carrying Case Included

PDL 200 £79.95

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

PDL 234Multifunction Part P Loop TesterEasy to use Part P verification

7

Loop T

este

rs

� 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Accurate mains voltage measurement to latest BS 7697, HD 472 S1

� Built in proven SOK 32 correct wiring indication - see page 30for complete fault indication chart

� Unique Socket & See Polarity test gives ultimate overallsystem safety check

� Carrying case included

NEWVERIFICATION

PARTGUIDE INCLUDED

STEP BY STEP

AS USED BY...

BritishGas

Additional/spare Test Leads available - see page 23-25

WHAT’S INCLUDED

PDL 234 Part P Loop Tester £89.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 234 Instruction Manual Included

TECC 10 Carrying Case Included

PDL 234 £89.95

Wiring TestDetects missing E or N (>15kΩ)Detects L-E or L-N swapDetects Live - Earth/Neutral reversal by use of Polarity Test PadFault indicated by chart on front of instrumentPhase voltage measurement accuracy 1% and displayed on 3 LED’s

<207V AC LOW207-253V AC STANDARD>253V AC HIGH

Loop TestContinuous reading loop resistance (Rl + Re) with result displayed on 5 LED’sTest current <15mA at 253V AC

Range<1Ω<2Ω<100Ω<200Ω>200Ω

Each breakpoint has an accuracy of ± 10%Test stops within 30ms if measured EARTH potential >25V AC and ‘Earth Fault’ indication displayed

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . 80% @ 310C to 50% @ 400CSize . . . . . . . . . . . . . . . . . . . . . . . . . . 140mm x 80mm x 31mm with fixed leadWeight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250g

StandardsCE MarkedComplies with BS EN 61010-1: 300V Cat IIIComplies with BS EN 61326 (with amendment A1)

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

Loop Testers

www.socketandsee.co.uk

Loop Testers

8

PDL 234 PLUSMultifunction Part P Loop Testing KitEverything you need for Part P compliance

WHAT’SIN THE KIT

ContentsPDL 234 Part P Loop Tester £89.95

ITLS 400 Fused Test Lead Set £34.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 234 Instruction Manual Included

TECC 10 Carrying Case Included

£124.90

IECP UKA ITLS 400

� 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Accurate mains voltage measurement to latest BS 7697, HD 472 S1

� Built in proven SOK 32 correct wiring indication - see page 30for complete fault indication chart

� Unique Socket & See Polarity test gives ultimate overallsystem safety check

� Carrying case included

NEWVERIFICATION

PARTGUIDE INCLUDED

STEP BY STEP

AS USED BY...

BritishGas

PDL 234 PLUS £119.95

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

KITSAVERPRICE

See page 7 for Technical Specificationi

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

PDL 310Part P MultifunctionDigital Loop TesterPART P Loop Test measurement including Prospective Fault Current

� 4 in 1 digital tester - loop (including PFC), mains voltage,correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Instant readout of PFC (Prospective Fault Current)

� Built in proven SOK 32 correct wiring indication

� Accurate mains voltage measurement to latest BS7697

� Unique Socket & See Polarity test gives ultimate overallsystem safety check

� Carrying case included

NEWSMART LOOP TEST

SLTVERIFICATION

PARTEDITION FULLY CERTIFIED

BS EN61557

GUIDE INCLUDED

STEP BY STEP

9

Loop T

este

rs

Additional/spare Test Leads available - see page 23-25

WHAT’S INCLUDED

PDL 310 Part P Loop Tester £179.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 310 Instruction Manual Included

TECC 10 Carrying Case Included

PDL 310 £179.95

Wiring TestDetects missing E or N (>15kΩ)Detects L-E or L-N swapDetects Live - Earth/Neutral reversal by use of Polarity Test PadFault indicated by chart on front of instrumentPhase - Neutral voltage measurement ± 1% ± 1V

Loop TestNo trip mode 3 wire testing Phase - Neutral - Earth all connectedTest current <15mA at 253V ACRange Accuracy0.00 to 9.99Ω ± 5% ± 5 digits10.00 to 99.9Ω ± 4% ± 4 digits100.00 to 500Ω ± 4% ± 4 digits

PFC Measurement10A - 9.99kA This is a calculated measurement whose accuracy is

derived from the Loop Test result

Over Voltage Protection440V AC No damage - complete recovery

Power4 x AA batteries (not included)Battery life (BS EN 61557) > 10,000 test (or shelf life of batteries installed)

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . . 80% @ 31˚C to 50% @ 40˚CSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157mm x 89mm x 39mmWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400g

16TH EDITION COMPLIANCE 313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

713-12 Prospective fault current

Loop Testers

Loop Testers

www.socketandsee.co.uk10

PDL 310 PLUSMultifunction Part P Loop Testing Kit

WHAT’SIN THE KIT

ContentsPDL 310 Part P Loop Tester £179.95

ITLS 400 Fused Test Lead Set £34.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 310 Instruction Manual Included

TECC 10 Carrying Case Included

£214.90

� 4 in 1 digital tester - loop (including PFC), mains voltage, correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Instant readout of PFC (Prospective Fault Current)

� Built in proven SOK 32 correct wiring indication - see page 30for complete fault indication chart

� Accurate mains voltage measurement to latest BS 7697, HD 472 S1

� Unique Socket & See Polarity test gives ultimate overallsystem safety check

� Carrying case included

NEWSMART LOOP TEST

SLTVERIFICATION

PARTEDITION FULLY CERTIFIED

BS EN61557

GUIDE INCLUDED

STEP BY STEP

PDL 310 PLUS £199.95

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

713-12 Prospective fault current

KITSAVERPRICE

IECP UKA ITLS 400

See page 9 for Technical Specificationi

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

Loop T

este

rsDL 42016th Edition MultifunctionDigital Loop TesterThe ultimate 16th edition instrument

� 4 in 1 digital tester - loop (including PFC), mains voltage,correct wiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Instant readout of PFC (Prospective Fault Current)

� Built in proven SOK 32 correct wiring indication - see page 30for complete fault indication chart

� Accurate mains voltage measurement to latest BS7699

� Unique Socket & See Polarity test gives ultimate overall systemsafety check

� Carrying case included

� Uses true impedance technique for accurate measurement ofLoop and Prospective Fault Current (PFC) at origin

NEWSMART LOOP TEST

SLTIMPEDANCE

TRUE LOOP

EDITION FULLY CERTIFIED

BS EN61557

Additional/spare Test Leads available - see page 23-25

WHAT’S INCLUDED

DL 420 16th Edition Loop Tester £199.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 420 Instruction Manual Included

TECC 10 Carrying Case Included

DL 420 £199.95

11

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

713-12 Prospective fault current

Wiring TestDetects missing E or N (>15kΩ)Detects L-E or L-N swapDetects Live - Earth/Neutral reversal by use of Polarity Test PadFault indicated by chart on front of instrumentPhase - Neutral voltage measurement ± 1% ± 1VPhase - Earth voltage measurement ± 1% ± 1VNeutral - Earth voltage measurement ± 1% ± 1V

Loop TestNo trip mode 3 wire testing Phase - Neutral - Earth all connectedTest current <15mA at 253V ACRange Accuracy0.00 to 9.99Ω ± 5% ± 5 digits10.00 to 99.9Ω ± 3% ± 3 digits100.00 to 500Ω ± 3% ± 3 digits

High current mode 2 wire testing Phase-Neutral or Phase-Earth connectedusing true impedance measurement - auto test (hands free) is selectable.

Range Accuracy0.00 to 9.99Ω ± 3% ± 3 digits10.00 to 99.9Ω ± 3% ± 3 digits100.00 to 500Ω ± 3% ± 3 digits

PFC Measurement10A - 19.9kA This is a calculated result using the loop test

measurement but it will be inherently more accurate than traditional methods as the test is of impedance not solely resistance

Over Voltage Protection440V AC No damage - complete recovery

Power4 x AA batteries (not included)Battery life (BS EN 61557) > 10,000 test (or shelf life of batteries installed)

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00C to 400CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100C to 600COperating Humidity . . . . . . . . . . . . . . . . . . . . . . . 80% @ 31˚C to 50% @ 40˚CSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157mm x 89mm x 39mmWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400g

Loop Testers

Loop Testers

www.socketandsee.co.uk12

DL 420 PLUSMultifunction 16th EditionLoop Testing KitEverything you need for full Loop testing

WHAT’SIN THE KIT

ContentsDL 420 16th Edition Loop Tester £199.95

ITLS 400 Fused Test Lead Set £34.95

IECP UKA 13A Plug to IEC Female Connector Included

PDLINS 420 Instruction Manual Included

TECC 10 Carrying Case Included

£234.90

� 4 in 1 digital tester - loop (including PFC), mains voltage, correctwiring, correct polarity

� Patented no-trip loop test technology

� Fully protected against accidental phase to phase connection

� Instant readout of PFC (Prospective Fault Current)

� Built in proven SOK 32 correct wiring indication

� Accurate mains voltage measurement to latest BS7697

� Unique Socket & See Polarity test gives ultimate overall systemsafety check

� Carrying case included

� Uses true impedance technique for accurate measurement ofProspective Fault Current (PFC)

NEWSMART LOOP TEST

SLTIMPEDANCE

TRUE LOOP

EDITION FULLY CERTIFIED

BS EN61557

DL 420 PLUS £229.95

16TH EDITION COMPLIANCE313-01 Nature of supply (voltage measurement)

713-10 Earth electrode resistance

713-11 Earth fault loop impedance

713-12 Prospective fault current

KITSAVERPRICE

IECP UKA ITLS 400

See page 11 for Technical Specificationi

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

RCD

Tes

ters

13

RCD

Tes

ters

RCD Testers

13

PDRC 380

RCD Tester

£179.95

Tests 30mA and 100mA RCD’s �

Full manual test selection �

Auto test (automatic sequence) �

x 1 I n trip test �

x 5 I n (30mA RCD) fast trip test �

x 1/2 I n non trip test �

Clear read out with 0.1ms resolution �

PRODUCT

FEATURES

PRICE

RCD Testers & Test Leads

PDRC 380Part P MultifunctionDigital RCD TesterRCD Testing made simple!

Additional/spare Test Leads available - see page 23-25

WHAT’S INCLUDED

PDRC 380 Part P RCD Tester £179.95

IECP UKA 13A Plug to IEC Female Connector Included

PDRCINS 380 Instruction Manual Included

TECC 10 Carrying Case Included

PDIT 360 £179.95

� Easy to use with auto sequence (not auto test) or manual override- you are in control of the test

� Auto sequence test in line with latest NICEIC recommendations -x 1, x 5, x 1/2

� Guaranteed to test all common types of 30mA and 100mA RCDs� Fully conforms with latest 16th edition and safety standards� Built in proven SOK 32 correct wiring indication -

see page 29 for complete fault indication chart� Accurate mains voltage measurement to latest

BS7697, HD 472 S1� Unique Socket and See polarity test gives ultimate

overall system safety check

NEWVERIFICATION

PARTEDITION FULLY CERTIFIED

BS EN61557

GUIDE INCLUDED

STEP BY STEP

www.socketandsee.co.uk

16TH EDITION COMPLIANCE713-13-01 Functional Testing

14

RCD

Testers

FeaturesType AC breakers30ma breakers x1/2 x1 x5 test currents100ma breakers x1/2, x1 test currentsUnlimited number of RCD testsRCD test polarity changeAuto / Manual test on both breakersFull socket test and mains polarity testComplies with EN61557 parts 1 and 6 (performance)Complies with EN61010 (safety)Complies with EN61326 (EMC)

RCD Test Range (to EN61557-6)Supply voltage 195V – 253V AC 50HzTest current accuracy (1/2 I) –0% to –10%Test current accuracy (I, 5I) +0% to +10%Trip time accuracy Up to 1 second +/-(1% + 1ms)

Over 1 second +/-(1% +10ms)

Voltage measurementRange 5V to 440V +/-(2% + 1V) over the working frequency range of 50Hz +/-0.5%

Socket testDetects opens, shorts, wrong wiring, phantom conditions, phase reversal, out of limits voltage.

Fault Touch VoltageTest terminated if >25V

Power4 x AA batteries ‘Alkaline’ recommendedBattery life 10,000 testsFitted fuse 32mm 0.25A (F) HBCSurvives 440V over voltage test rated for 1 minute.

EnvironmentalOperating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0˚C to 40˚CStorage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . -10˚C to +60˚COperating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93% RH @ 40˚CSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157mm x 89mm x 39mmWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400g

Call +44 (0)1256 864100Freefax Sales Order 0800 7831385

Test

Lea

ds

15

ITLS 400 IEC Fused Test Lead SetWHAT’S

IN THE KIT

ContentsIEC Female Connector to 2 x Fused Prods - 1 brown, 1 blue + 1 x 4mm green stackable connector

2 x Push on tips - 1 brown, 1 blue

3 x Push on crocodile clips - 1 brown, 1 blue, 1 green

KITSAVERPRICEITLS 400 £34.95

NEW

FUSED & TIPS

GS 38

SS 130 Socket Interface Connector

SS 130

£14.95This product is designed for use by trained personnel for testingpurposes only. It must not be used for any other purposes.

� Save time - leave the socket in place

� Safer - leave the socket in place

� No broken connections - leave the socket in place

� No damage to decoration - leave the socket in place

Advantage!The crocodile clips just pull off...

If you’ve been using croc clips at adistribution board, and now wantto test a luminaire you need to puton the probes to get into theconnecting strip for the luminaire.

New test leads.... and the probesjust click back on,it could not besimpler!

Changing from crocodile clips to probes, with new ITLS 400 leads to test a luminaire.

� The safe way to connect to distribution boards, busbars, luminaires and spur outlets

� Big leap forward in safety - no need to screw andunscrew prods and crocodile clips - just push on-pull off

� As well as advancing safety, new system gives big timesavings

� New harmonised colour system of phase-brown,neutral-blue (with gentle reminder at strain relief of oldred/black equivalents)

� Stackable earth crocodile clip means no more trying toget 2 crocodile clips onto the same measuring point

Advantage!Now you can simply connect,using just two croc clips, oneon the live and a singlecombined neutral/earthonto any other point.

Advantage!You are ready to go in an instant!

Advantage!Remove probes in an instant,click live croc clip back on.

Advantage!The connector has a small contactarea, so you’ll need to get twocroc clips onto the same point.With the new leads you can usethe ‘piggy back’ system. Neutralcombines with the earth meansjust one croc clip to connect.

Advantage!The fuses remain in theprobes at all times, thereforea good contact is alwaysassured.

Making a connection to a small connector area to measure, say Prospective Fault Current.35seconds