2013 high tech update - l973d1 973d - 2013 high tech update

61
2013 High Tech Update - L973D 1 973D - 2013 High Tech Update

Upload: chrystal-dixon

Post on 13-Jan-2016

228 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 1973D - 2013 High Tech Update

Page 2: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 2973D - 2013 High Tech Update

PicoScope Advance FeaturesPicoScope Advance Features

• Objectives

– Proficiency with PicoScope Advanced Features:• Triggers

• Rulers

• Masks

• Alarms

• Reference Waveforms

– Manipulate and Save Waveforms• Load and view saved waveforms

– Use of the Toyota Waveform Library• Load “Known Good” waveforms

• Compare “Known Good” waveforms to live data

Page 3: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 3973D - 2013 High Tech Update

PicoScope Software PicoScope Software

This is the Windows Command Bar that loads with PicoScope for TMS*.

It includes the Demo Device software

* With the PicoScope plugged into the computer.

Page 4: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 4973D - 2013 High Tech Update

PicoScope Software PicoScope Software

“PicoScope TMS” links to the PicoScope software with the

“Automotive” database and the “Demo” program.

“TMS Database Launcher” Links to the Lexus Waveform Database and

launches the PicoScope software with the link to that database.

Open the “Start” menu now and launch the “PicoScope TMS” Software.

Page 5: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 5973D - 2013 High Tech Update

PicoScope SoftwarePicoScope Software

Page 6: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 6973D - 2013 High Tech Update

PicoScope Screen DivisionsPicoScope Screen Divisions

Time 10 Divisions

V

olt

age

10

Div

isio

ns

Page 7: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 7973D - 2013 High Tech Update

PicoScope Screen DefaultsPicoScope Screen Defaults

The default position for “0” on the vertical axis is in the

center of the screen.

The default position for “0” on the horizontal axisis at the left of the screen.

Page 8: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 8973D - 2013 High Tech Update

PicoScope ScreenPicoScope Screen

If the “0” point on the vertical axis does not line up with a hash mark, the “0” position is indicated with a dash.

Page 9: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 9973D - 2013 High Tech Update

PicoScope ToolbarsPicoScope Toolbars

PicoScope Tool Bars

Scope Mode. This sets up PicoScope to operate as an oscilloscope. This is the default.

Auto Setup. Clicking on this icon sets up the timebase and signal range (voltage) to display the signal. This is usually a good starting point.

Home. Restores PicoScope to its default settings. Equivalent to the File > Startup Settings > Load Startup Settings command.

Timebase Control. Sets the time represented by a single division of the horizontal axis when the horizontal zoom control is set to x1

Horizontal Zoom Control. Usually set to x1. Used to stretch the waveform along the horizontal axis without changing the voltage scale.

Page 10: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 10973D - 2013 High Tech Update

PicoScope Channel ToolbarPicoScope Channel Toolbar

Channel Toolbar for Channel “A”.

Channel Options button. Opens the Channel Options menu with options for:•Probes•Resolution enhancement, •Scaling and filtering.

Range control. Sets up the scope device to capture signals over the specified range of values. In “Auto” PicoScope continually adjusts the vertical scale to the Waveform.

Coupling Control. Sets up the input circuitry.•AC coupling: Rejects frequencies below about 1 Hz. •DC coupling: Accepts all frequencies from DC to the scope's maximum bandwidth.

Page 11: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 11973D - 2013 High Tech Update

PicoScope ProbesPicoScope Probes

Channel Options Icon / Menu

Built-in probes. The built-in probes are supplied by Pico and do not change unless you download an authorized PicoScope update.

PicoScope Probes Menu

Page 12: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 12973D - 2013 High Tech Update

PicoScope ProbesPicoScope Probes

Hint: The Channel Options icon is greyed out when the Input

Range for the channel is “Off”.

Page 13: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 13973D - 2013 High Tech Update

Overrange IndicatorOverrange Indicator

Set the voltage range to 2 volts

Page 14: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 14973D - 2013 High Tech Update

Overrange IndicatorOverrange Indicator

This symbol indicates that the trace is off the screen.

The Overrange Indicator will appear

when the input exceeds the channel’s range

After observing the Overrange Indicator, set

the range on channel “A” back to “Auto”.

Page 15: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 15973D - 2013 High Tech Update

Choosing TriggersChoosing Triggers

Page 16: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 16973D - 2013 High Tech Update

Setting TriggersSetting Triggers

This is the Trigger Menu

The Trace will not startuntil the voltage level rises

by .215 volts

Page 17: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 17973D - 2013 High Tech Update

Set a Trigger to Stabilize the PatternSet a Trigger to Stabilize the Pattern

Click on “Auto”

Set a Trigger to stabilize the pattern

Drag the “Trigger Diamond” up from “0” volts to stabilize the trace

Page 18: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 18973D - 2013 High Tech Update

Stopping the TraceStopping the Trace

Start and Stop buttons

Hint: The trace can be started and stopped with the space

bar, but only if your last mouse click was on the white portion

of the screen.

Page 19: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 19973D - 2013 High Tech Update

PicoScope Toolbars (Continued)PicoScope Toolbars (Continued)

Samples Control. Sets the maximum number of samples that will be captured for each channel.

The Buffer Navigation Toolbar allows you to select a waveform from the waveform buffer.

The Buffer Navigation Button in the Button Navigation Toolbar allows quick navigation of saved waveforms in the buffer.

Waveform Number Indicator. Shows which waveform is currently displayed, and how many waveforms are currently in the buffer.

Page 20: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 20973D - 2013 High Tech Update

PicoScope Toolbars (Continued)PicoScope Toolbars (Continued)

Normal Selection Tool. Use this pointer to click buttons, drag and operate any other controls in the PicoScope window.

Hand tool. Use to click and drag the view to pan it vertically and horizontally when you are zoomed in.

Zoom-In or Zoom Out Tool. Turns the pointer into a zoom-in or zoom out tool.

Marquee Zoom Tool. Use it to draw a box (called a marquee) on the view and PicoScope will magnify that box to fill the view.

Zoom to full view. Resets the view to normal size. The view will no longer have scroll bars, and panning will no longer be possible.

Page 21: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 21973D - 2013 High Tech Update

Timebase RulersTimebase Rulers

Change the scaling on the NE waveform to 50%

To add the NE waveformTo the display, change channel

“D” to “Auto”

Page 22: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 22973D - 2013 High Tech Update

Timebase RulersTimebase Rulers

The timebase rulers display RPM and Hz here.

Page 23: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 23973D - 2013 High Tech Update

Horizontal (Voltage) RulersHorizontal (Voltage) Rulers

To display Injector Amps,Set channel “B” to “Auto”

Page 24: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 24973D - 2013 High Tech Update

PicoScope File MenuPicoScope File Menu

This is the File Drop Down Menu

Page 25: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 25973D - 2013 High Tech Update

PicoScope Edit MenuPicoScope Edit Menu

This is the Edit Drop Down Menu

When you click on “Notes” this Notes Field opens at the Bottom

of the Screen

Page 26: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 26973D - 2013 High Tech Update

PicoScope View MenuPicoScope View Menu

This is the Views Drop Down Menu

Page 27: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 27973D - 2013 High Tech Update

Waveform Properties Waveform Properties

The “Properties” tab in the Views drop down menu

displays waveform information.

Page 28: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 28973D - 2013 High Tech Update

PicoScope Measurements MenuPicoScope Measurements Menu

This is the Measurements Drop Down Menu

Hint: When measuring between rulers, capture

more than 2 cycles.

Page 29: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 29973D - 2013 High Tech Update

PicoScope Tools MenuPicoScope Tools Menu

This is the Tools Drop Down Menu

This is the “General” tab under “Preferences”.

Page 30: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 30973D - 2013 High Tech Update

PicoScope Tools MenuPicoScope Tools Menu

This is the Tools Drop Down Menu

This is the “Colors” tab under “Preferences”.

Hint: To change the colors on a previously saved waveform, change the colors prior to

opening the waveform.

Page 31: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 31973D - 2013 High Tech Update

Starter Draw WorksheetStarter Draw Worksheet

This Worksheet Highlights Triggers and the use of the

600a Amp Clamp.

Page 32: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 32973D - 2013 High Tech Update

Starter Draw WorksheetStarter Draw Worksheet

The Starter Draw worksheet requires 3 captures:1.Normal Start2.Starter draw with Injection fuse pulled.3.Starter draw with Injection fuse pulled and one spark plug removed.

• All traces should span the entire screen.

Starter Draw Worksheet Common Issues:

• Amp Clamp:• Amp Clamp not turned on. • Amp Clamp battery weak.• Amp Clamp not zeroed.• Amp Clamp on backwards.• Incorrect range selection

• Trigger:• Set on the incorrect channel.• Set out of range• Set on falling trace.

Page 33: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 33973D - 2013 High Tech Update

Starter Draw WorksheetStarter Draw Worksheet

Amp clamp on Backwards

The Amp Clamp can only measure 100 amps in the negative direction.

This results in the trace going off the screen.

Page 34: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 34973D - 2013 High Tech Update

Starter Draw WorksheetStarter Draw Worksheet

Trigger set on Channel “A”

Since the PicoScope is in “streaming” mode, and the trigger is not met, the waveform does not start. Instead, it streams off the left of the screen.

Page 35: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 35973D - 2013 High Tech Update

Starter Draw WorksheetStarter Draw Worksheet

Page 36: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 36973D - 2013 High Tech Update

Starter Draw Worksheet ReviewStarter Draw Worksheet Review

1. Normal StartAnimations\Starter Worksheet Waveform 1.psdata

2. Starter draw with Injection fuse pulled. Animations\Starter Worksheet Waveform 2.psdata

3. Starter draw with Injection fuse pulled and one spark plug removed.Animations\Starter Worksheet Waveform 3.psdata

Page 37: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 37973D - 2013 High Tech Update

MasksMasks

Increase the “Y” Offsetto make the Mask less sensitive

Generate a Mask of Waveform “D”

Page 38: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 38973D - 2013 High Tech Update

MasksMasks

Page 39: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 39973D - 2013 High Tech Update

MasksMasks

Hint: Disable the Mask before saving the

waveform.

Page 40: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 40973D - 2013 High Tech Update

AlarmsAlarms

Must be checked to be enabled

To display channel “D”, set it

to “Auto”.

Page 41: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 41973D - 2013 High Tech Update

Mask & Alarm WorksheetMask & Alarm Worksheet

The Mask and Alarm Worksheet Requires 1 capture:

1.Parasitic Draw Mask with Alarm set to:• Beep.• Save current waveform.

• Vehicle Setup:• Place amp clamp on battery cable with arrow towards negative.• Hood closed or Hood latch latched.• All doors locked and Smart Key out of range.• Amp clamp zeroed.• Amp clamp turned on.

• Alarm:• Disable mask and alarm before saving PicoScope file.

• Sample Alarm Capture:

• Animations\parasitic draw mask fail.psdata

Page 42: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 42973D - 2013 High Tech Update

Mask & Alarm WorksheetMask & Alarm Worksheet

Page 43: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 43973D - 2013 High Tech Update

Reference WaveformsReference Waveforms

Page 44: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 44973D - 2013 High Tech Update

Using Reference WaveformsUsing Reference Waveforms

Page 45: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 45973D - 2013 High Tech Update

Using Reference WaveformsUsing Reference Waveforms

Live

Page 46: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 46973D - 2013 High Tech Update

Scaling / Offset ControlsScaling / Offset Controls

Scale Control

Offset Control

Delay Control

Send to back

Bring to front

Page 47: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 47973D - 2013 High Tech Update

Reference Waveform WorksheetReference Waveform Worksheet

The Reference Waveform Worksheet Requires 2 captures:

1.Capture a Fuel Pump Waveform.• Use the Techstream Active Test to turn the Fuel Pump on and off.• Save the waveform.

2.Using the Waveform that you saved in step 1.• Convert the screen capture into a reference waveform.• Using the reference waveform file just created, run the ABS active

test again and save a file with both patterns.

Sample Reference Waveform Capture:

• Animations\Corolla fuel pump.psdata

Page 48: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 48973D - 2013 High Tech Update

Reference Waveform WorksheetReference Waveform Worksheet

Page 49: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 49973D - 2013 High Tech Update

PicoScope Best PracticesPicoScope Best Practices

• Use of the TMS Waveform Library

• Ground Plane Issues

• Pico Gap Work Around

• Passive 20:1 attenuator

Page 50: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 50973D - 2013 High Tech Update

PicoScope Waveform DatabasePicoScope Waveform Database

Generic vehicle Selections Available under Charging and

Starting.

Hint: The “Automotive” tab is replaced with a Model Specific tab whenUsing the TMS Database Launcher to start the PicoScope software.

Page 51: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 51973D - 2013 High Tech Update

TMS PicoScope Waveform LibraryTMS PicoScope Waveform Library

Clicking on the TMS Database Desktop Icon brings up the

PicoScope WaveformLibrary Launcher.

Clicking on “Skip” will launch PicoScope with the Pico Automotive Menu

Page 52: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 52973D - 2013 High Tech Update

PicoScope Waveform LibraryPicoScope Waveform Library

This is the Windows Command Bar that loads with TMS Waveform Database*.

It does not include the Demo Device Software

Page 53: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 53973D - 2013 High Tech Update

TMS PicoScope Waveform LibraryTMS PicoScope Waveform Library

Here is an example of a CAN signal from the TMS

Waveform Library.

Hook up the PicoScope per the “Notes” section to capture this waveform.

Page 54: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 54973D - 2013 High Tech Update

Ground Plane IssuesGround Plane Issues

The PicoScope Inner Circuitry connects the ground side of all the inputs together.

It is a good practice to ground only one PicoScope lead and that ground should be the negative battery cable

Page 55: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 55973D - 2013 High Tech Update

“Pico Gap”“Pico Gap”

Is data lost in the gap between screens?

Page 56: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 56973D - 2013 High Tech Update

Pico Gap Work AroundPico Gap Work Around

Trigger must be out of waveform’s range

Page 57: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 57973D - 2013 High Tech Update

Pico Gap Work AroundPico Gap Work Around

Notice that the glitch has been captured

Page 58: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 58973D - 2013 High Tech Update

PicoScope Over Voltage ProtectionPicoScope Over Voltage Protection

Passive 20:1 attenuator

Page 59: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 59973D - 2013 High Tech Update

QuestionsQuestions

Questions????

Page 60: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 60973D - 2013 High Tech Update

PicoScope Proficiency WorksheetPicoScope Proficiency Worksheet

To complete the PicoScope Proficiency Worksheet:

•Create a reference waveform from the CAN KOEO waveform in the TMS Database.•Capture a live waveform that matches the CAN KOEO waveform.•Save that one screen as a PicoScope file.•Show your results to your Instructor.

Here is an example of the waveform:

• Animations\Final CAN Worksheet.psdata

•For extra credit Change the colors so that CAN Hi is red and CAN Lo is blue.

• Refer to the file above.

Page 61: 2013 High Tech Update - L973D1 973D - 2013 High Tech Update

2013 High Tech Update - L973D 61973D - 2013 High Tech Update

Hi Tech Final WorksheetHi Tech Final Worksheet