2013 inspection presentation.ppt · hampton northfield dale ruedy 651-675-4548 cda owned properties...

36
HOUSING INSPECTORS Anne Pillsbury 651-675-4539 Apple Valley Farmington Lakeville Rosemount Hastings Cannon Falls Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights West St Paul South St Paul

Upload: others

Post on 12-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

HOUSING INSPECTORSAnne Pillsbury

651-675-4539

Apple ValleyFarmingtonLakevilleRosemountHastingsCannon FallsHamptonNorthfield

Dale Ruedy

651-675-4548

CDA Owned PropertiesSenior Buildings

Luki Murumba

651-675-4532

BurnsvilleEaganInver Grove HeightsWest St PaulSouth St Paul

Page 2: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

HQS Inspection Basics

1. Electrical Hazards2. Window Conditions3. Sinks4. Smoke/Carbon Monoxide Detectors5. Interior and Exterior Hazards6. Stairs7. Stove/Oven8. Bathrooms9. Water Heaters10. Lead Based Paint

Page 3: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights
Page 4: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#1 Electrical Hazards

Missing light globes Open junction boxes Overloaded power strips Extension cables on garage door opener Open slots in circuit panel Missing garbage disposal stress clamps

Page 5: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Outlets

Causes of failure

Loose/cracked covers Inoperable GFCI test buttons Improperly wired Inoperable

Note: Outlets can be ungrounded if protected by a GFCI and labeled as such.

Page 6: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 7: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 8: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 9: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 10: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 11: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 12: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 13: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#2 Window Conditions

Causes of failure Missing or torn screens

Broken locks (first floor windows)

Broken/cracked panes

Windows that won’t open or don’t stay open

Broken handles

Excessive air infiltration

Page 14: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Egress windows are required in basement rooms if used for sleeping.

Page 15: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 16: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#3 Sinks

Causes of failure Leaky drain pipes

Loose faucets

Water damage in base cabinets

Missing/improper p-traps

Page 17: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 18: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 19: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#4 Smoke/Carbon Monoxide Alarms

HQS Requirements One smoke alarm is required in a common area on

every level C/O alarms must be within 10 feet of every

bedroom Hearing impaired tenants require a special strobe

light smoke alarm that is linked from sleeping rooms to a common area.

Causes of failure Inoperable alarms Hanging or missing alarms Low battery signals (Chirping) Smoke alarms located too close to walls

Page 20: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 21: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 22: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#5 Interior/Exterior Hazards

Any situation that presents a safety hazard

Tripping Hazards

Worn carpet

TV cables

Missing carpet bars

Other

Blocked exits

Sharp objects

Unstable fences

Page 23: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Hoarding… A sensitive subject

What is Hoarding? Severe cluttering of the person's

home so that it is no longer able to function as a viable living space

Living styles of tenants can vary greatly from tenant to tenant.

Though a unit CANNOT fail an inspection for being “messy,” a unit CAN fail if excessive clutter causes air quality issues or fire hazards (blocked windows/pathways).

Page 24: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 25: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#6 Stairs

No Loose, broken, or missing steps

Handrails are required on sections of stairs with four or more consecutive steps

A railing is required for areas with a drop off of more than 30 inches

Page 26: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 27: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 28: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#7 Stove/Oven

Causes of Failure Inoperable burners Excessive debris around or

underneath burners Missing drip pans Missing knob and handles Missing oven gasket

Page 29: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#8 Bathrooms

Causes for failure Excessive mold

Missing shower tiles

Clogged drains

Wobbly toilets

Broken toilet seats and covers

Inoperable vent fans

Page 30: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#9 Water Heaters

Temperature and pressure valve T&P relief valve T&P relief tube Exhaust tube must be secured to

tank and must have constant positive slope.

Base cover must be in place

Page 31: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#9 Water Heaters

Page 32: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Pass

Page 33: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Fail

Page 34: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#10 Lead Based Paint

All homes built prior to 1978 inhabited by children under the age of 6 will be checked for chipping and peeling paint.

Lead was a common ingredient in paint until 1978.

Paint ingest by children can cause brain damage.

Page 35: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

#10 Lead Based Paint

Page 36: 2013 Inspection presentation.ppt · Hampton Northfield Dale Ruedy 651-675-4548 CDA Owned Properties Senior Buildings Luki Murumba 651-675-4532 Burnsville Eagan Inver Grove Heights

Repair Certifications

Can be used to certify correction of non-emergency HQS failures.

Requires signatures from the Landlord and tenant.