For Metal Roofing • R-Values from 9.1 to 45.7 • Single layer of sheathing For Shingles and Metal Roofing • R-Values from 8.5 to 39 • Single layer of sheathing For Slate, Tile and Maximum Loading • R-Values from 9.1 to 36.6 • Two layers of sheathing All of Our Ventilated Panels Feature: • Industry-Leading Airflow • Solid-Wood Spacer Block Construction for Maximum Strength and Minimum Deflection • 1" Airspace Standard, 1-1/2" and 2" Airspace Optional All Of Our Vented & Non-Vented Panels Feature: • Fully-Machined Construction • Tongue and Groove Foam Available At No Extra Cost • Minimum Heat Loss • Best Fit-Panels Pre-Spaced • 7/16" OSB Nailing Surface Standard; Optional 5/8" and 3/4" OSB or Plywood, FRT or RB OSB or Plywood, FSC Chain-of-Custody Secure Installation with Cornell SIP Fasteners Industry-Leading Airflow! INNOVATIVE BUILDING PRODUCTS SINCE 1954 2" "The Original Ventilated Roof Insulation Since 1987" "The Original Nailbase Roof Insulation Since 1979" "The Original Nailbase Roof Insulation Since 1979" Get BIM & CAD & Complete Specs and Downloads at CornellCorporation.com Featuring Insulation ROOFING INSULATION PRODUCTS

Upload: mike-coughlin

Post on 10-Jan-2017

41 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 2014 Cornell GAF brochure

For Metal Roofing• R-Values from 9.1 to 45.7• Single layer of sheathing

For Shingles and Metal Roofing

• R-Values from 8.5 to 39• Single layer of sheathing

For Slate, Tile andMaximum Loading

• R-Values from 9.1 to 36.6• Two layers of sheathing

All of OurVentilated Panels Feature:

• Industry-Leading Airflow• Solid-Wood Spacer Block Construction for

Maximum Strength and Minimum Deflection• 1" Airspace Standard, 1-1/2" and 2" Airspace

Optional

All Of Our Vented & Non-Vented

Panels Feature:

• Fully-Machined Construction • Tongue and Groove Foam Available At No

Extra Cost • Minimum Heat Loss • Best Fit-Panels Pre-Spaced • 7/16" OSB Nailing Surface Standard; Optional

5/8" and 3/4" OSB or Plywood, FRT or RB OSB or Plywood, FSC Chain-of-Custody

• Secure Installation with Cornell SIP Fasteners

Industry-Leading Airflow!

INNOVATIVE BUILDING PRODUCTS SINCE 1954

2"

"The Original Ventilated Roof Insulation Since 1987"

"The Original Nailbase Roof Insulation Since 1979"

"The Original Nailbase Roof Insulation Since 1979"

Get BIM & CAD

& Complete Specs and Downloads at

CornellCorporation.com

Featuring

Insulation

R O O F I N G I N S U L A T I O N P R O D U C T S

Page 2: 2014 Cornell GAF brochure

Standards- Vent-Top ThermaCal and ThermaCal

•ISO insulation complies with ASTM C1289, Type II, Class I, Grade 2

• Miami-Dade County, Florida NOA #07-0927.04 (with 5/8”min. plywood)

• FSC Chain-Of-Custody Certi cate #SGS-COC-005443• Standard APA/TECO rated OSB or optional plywood, FRT/RB plywood or OSB

FM Standard 4450/4470 Approval• ISO insulation approved for FM Class 1 insulated roof

deck construction

• Classi ed under L 790 as a Shingle Decking Acces-sory for use with Class A, B, or C shingles, metal, tile or slate roo ng coverings

• Classi ed for Insulated Metal Deck Assemblies, Constructions No. 120 and No. 123

• Sheathing- OSB conforms to APA Standard PRP 108, Exposure 1 and H D/FHA-918

• Polyisocyanurate Foam-Flame Spread per ASTM E84 of 40-70 feet-Moisture Vapor Permeance per ASTM E96 of less than 1.25 perm

(Vent-Top ThermaCal 1 and 2 only) Depth 1” standard, 1.5” and 2.0” optional Cross Section 10 Sq. In. of Net Free Area/Ln.Ft. (along the 8’ edge dimension after deducting spacer block area)

Open Area Not less than 92% of plan area Spacer Separation Less than 12” all directions

Always refer to local building codes

VENTILATED ROOFING

APPROX. OVERALL WEIGHT LTTR

THICKNESS P.S.F. R-VALUE*3.0" 75 mm 1.9 8.503.5" 89 mm 2.0 11.404.0" 102 mm 2.1 14.404.5" 114 mm 2.2 17.405.0" 127 mm 2.3 20.505.5" 140 mm 2.4 23.606.0" 152 mm 2.5 26.806.5" 165 mm 2.6 29.857.0" 178 mm 2.7 32.907.5" 190 mm 2.8 35.958.0" 203 mm 2.9 39.00

Panel Specifications

*LTTR R-value calculations based on ASTM C1289-11A, effective January 1, 2014. The nominal foam thickness is 1/2" less than the overall panel thickness.

For Shingles and Metal Roofing

• Single layer of sheathing• Nominal 4’ x 8’ panel

Industry-Leading Airflow!

THE FAMILY OF INSULATED ROOF PANELS

ROOF DECKMETAL. OR WOOD

ROOFING

1-1/2" x 1-1/2"FURRING

INSECTSCREEN

VENTILATED NAIL BASEINSULATION

AIRFLOW

LAMBEAM

• Over 92% open area - spacers occupy only 8% of panel area

• Solid wood spacers less than 12” apart in both directions to minimize deflection of top sheathing

Featuring

Insulation

Page 3: 2014 Cornell GAF brochure

SHORT FORM DRAFT SPECIFICATIONS

VENT-TOP THERMACAL 1® VENTILATED ROOF INS LATION

Note to Specification Writer: This draft spec can be used for Vent-Top ThermaCal 1 (with one layer of oriented strand board). This spec is usually placed in Section 07220. All product specifications can be downloaded from our website- www.cornellcorporation.com.

1. VENTILATED ROOF INS LATION

A. Description of system:

1. The ventilated roof insulation shall be a factory assembled panel consisting of one layer of 7/16” oriented strand board top surface, a built-in ventilation space maintained by 1” wood spacer blocks, and polyisocyanurate insulation on the bottom.

2. The Long Term Thermal Resistance (LTTR) R-Value of the venti-lated roof insulation shall be no less than ________.

3. Wood panel edges shall be rabbetted to allow the foam edges to fit together while providing clearance between the wood sheathing on adjoining panels.

4. Foam sides and ends shall have a machined tongue and groove profile to reduce heat loss at the joints.

5. The wood spacer blocks shall not exceed 8% of the panel area and shall have 50% open for lateral (across the slope) ventilation. Spacer blocks shall not be over 12” apart in either direction.

Panel Specifications

*LTTR R-value calculations based on ASTM C1289-11A, effective January 1, 2014.The nominal foam thickness is " less than the overall panel thickness.

APPROX. OVERALL WEIGHT LTTR THICKNESS P.S.F. R-VALUE*

3.5" 89 mm 3.3 9.104.0" 102 mm 3.4 12.004.5" 114 mm 3.5 15.005.0" 127 mm 3.6 18.005.5" 140 mm 3.7 21.106.0" 152 mm 3.8 24.206.5" 165 mm 3.9 27.407.0" 178 mm 4.0 30.507.5" 190 mm 4.1 33.508.0" 203 mm 4.2 36.60

6. The vent space shall provide a minimum of 10 sq.in. of Net Free Area per lineal foot of insulation (along the 8’ edge) after deduction for the spacer blocks.

7. The ventilated roof insulation will be attached with Cornell SIP Fasteners per specified wind load requirements.

2. S BMITTALS A. The following will be submitted to the architect for approval: Copies of the manufacturer’s product information and installation instructions. A sample with the edge profile specified and large enough to show the actual lateral spacing of the vent space supports. A manufacturer’s dimensioned drawing showing how the 50% lateral ventilation is achieved. Calculations of spacer block percentage of panel area and the Net Free Area per Lin.Ft. of insulation after deducting for spacers.

3. PROD CTS A. Products shown below are acceptable provided they meet the requirements of this specification. 1) Vent-Top ThermaCal 1® Roof Insulation by Cornell by GAF, Cornell, WI Phone: (715) 239-6411 Fax: (800) 267-8368 www.cornellcorporation.com 2) Cornell SIP FastenersNote: The designer should determine if a vapor barrier is required between the deck and the insulation. A vapor retarder should always be specified in buildings with high humidity. Always refer to local building codes. Fastener Requirements: Cornell by GAF requires the use of the Cornell SIP Panel Fastener for steel and wood substrate applications for all nail-base roof and wall insulation products. See Instructions for recommended fastening patterns.

For Slate, Tile and Maximum Loading

• Two layers of sheathing• Nominal 4’ x 8’ panel

ENGINEERED TO SAVE ENERGY AND TIME!

SPECIFY

Tongue & Groove Edges

for Reduced

Heat Loss!

VENT-TOP THERMACAL©

PERFORMANCE FEATURE!

• The largest vent cross section avail-able -10 sq. in. per ft. run

• Over 86% open for up the slope ventilation and 50% open area for lateral ventilation

RIDGEVENT

SHINGLES

VENTILATED NAIL BASE

ROOF DECK—METAL OR WOOD

STEEL JOIST OR TRUSS

Industry-Leading Airflow!

Page 4: 2014 Cornell GAF brochure

1361 Alps Road • WAYNE, NEW JERSEY 07470ThermaCal is a Registered Trademark of Cornell Corporation

Tele: 888-439-6411 (Central Time) 800-522-9224Fax: 800-267-8368Email: [email protected] [email protected] 2014 Printed in SA Copyright 2014

QUALITY BUILDING ENVELOPE INSULATION FEATURING

NON-VENTILATED ROOFING

All Season Performance

• Fastens to outside wall sheathing and studs, metal or masonry walls without interior modifications

• Adds insulation value outside of stud wall

• Nailable base for siding• 7/16" OSB sheathing (optional 5/8" or

3/4" OSB or plywood)• FSC sheathing available• 4' x 8' nominal panel• Tongue and groove foam for minimal

heat loss• Sheathing pre-spaced for expansion• Qualifies towards LEED and Energy

Star program• Features GAF EnergyGuard™ ISO

insulation

EXTERIOR WALLS

• Fully machined composite panel• Sheathing pre-spaced for thermal expansion• 7/16” OSB standard; 5/8” or 3/4” OSB or plywood

optional• Nominal 4’ x 8’ panel

• Green energy-saving solution combining structure and insulation for difficult to insulate areas

• R-11 Insulation ideal for northern climates• Engineered with dimensionally accurate,

APA-Rated Rim Board and OSB bonded with polyisocyanurate foam for maximum thermal efficiency

• Sizes from 9-1/2"H to 24"H, 12'L

ABOVE THE FOUNDATION

tit bi i

Insulated Rim Board

i l

Panel Specifications

All Season Performance

APPROX. OVERALL WEIGHT LTTR THICKNESS P.S.F. R-VAL E

2.0" 51 mm 1.7 9.1 2.5" 64 mm 1.8 12 3.0" 75 mm 1.9 15 3.5" 89 mm 2.0 18 4.0" 102 mm 2.1 21.1 4.5" 114 mm 2.2 24.2 5.0" 127 mm 2.3 27.4 5.5" 140 mm 2.4 30.5 6.0" 152 mm 2.5 33.5 6.5" 165 mm 2.6 36.6 7.0" 178 mm 2.7 39.6 7.5" 190 mm 2.8 42.65 8.0" 203 mm 2.9 45.7

LTTR R-value calculations based on ASTM C1289-11A, effective January 1, 2014. The nominal foam thickness is 1/2" less than the overall panel thickness.

LTTR R-value calculations based on ASTM C1289-11A, effective January 1, 2014. The nominal foam thickness is 1/2" less than the overall panel thickness.

APPROX. OVERALL WEIGHT LTTR THICKNESS P.S.F. R-VALUE* 2.0" 51 mm 1.7 9.1 2.5" 64 mm 1.8 12 3.0" 75 mm 1.9 15 3.5" 89 mm 2.0 18 4.0" 102 mm 2.1 21.1 4.5" 114 mm 2.2 24.2 5.0" 127 mm 2.3 27.4 5.5" 140 mm 2.4 30.5 6.0" 152 mm 2.5 33.5 6.5" 165 mm 2.6 36.6 7.0" 178 mm 2.7 39.6 7.5" 190 mm 2.8 42.65 8.0" 203 mm 2.9 45.7

Panel

OSB or PLYWOODWALL STUDS

1/2" GYPSUM

OUTSIDE WALL

INSIDE WALL

FOAM

PLYWOOD

INSULATEDJOIST

PANEL

PLYWOODOR OSB

SIDING

SILLPLATE

I-JOIST or TRUSS

ANGLE SUPPORT(thicker sizes)

BLOCK, CONCRETEETC.

Cornell SIP Fasteners are a warranty require-ment and meet FM wind load requirements over steel and wood roof decks. Contact us for special applications.

CoCoCoCoCoCoCoCCCoCoooorrrnrnnnnnrr elele lllll SISIIISISIS PPPPPP FaFaFaFa tstststenennnnnnnnnerererrreerssss araararrreeee aaaa wwawawaw rrrrrr ananana ttyttytyty rrreqeqeqequiuiuiuirerereer ---

FASTENERS

ELIGIBLE FOR LEED CREDITS

gRoof Insulation Since 1979"

1361 Alpss RRRRRoad • WWWWWWAYAYAYAYAYAYNENENENENENE NENENENENENEWWWWWW JEJEJEJERSRSRSRSEYEYEYEY 000077474747

GAF.COM